Advertisement for orthosearch.org.uk
Results 1 - 50 of 673
Results per page:
Bone & Joint Open
Vol. 3, Issue 6 | Pages 502 - 509
20 Jun 2022
James HK Griffin J Pattison GTR

Aims. To identify a core outcome set of postoperative radiographic measurements to assess technical skill in ankle fracture open reduction internal fixation (ORIF), and to validate these against Van der Vleuten’s criteria for effective assessment. Methods. An e-Delphi exercise was undertaken at a major trauma centre (n = 39) to identify relevant parameters. Feasibility was tested by two authors. Reliability and validity was tested using postoperative radiographs of ankle fracture operations performed by trainees enrolled in an educational trial (IRCTN 20431944). To determine construct validity, trainees were divided into novice (performed < ten cases at baseline) and intermediate groups (performed ≥ ten cases at baseline). To assess concurrent validity, the procedure-based assessment (PBA) was considered the gold standard. The inter-rater and intrarater reliability was tested using a randomly selected subset of 25 cases. Results. Overall, 235 ankle ORIFs were performed by 24 postgraduate year three to five trainees during ten months at nine NHS hospitals in England, UK. Overall, 42 PBAs were completed. The e-Delphi panel identified five ‘final product analysis’ parameters and defined acceptability thresholds: medial clear space (MCS); medial malleolar displacement (MMD); lateral malleolar displacement (LMD); tibiofibular clear space (TFCS) (all in mm); and talocrural angle (TCA) in degrees. Face validity, content validity, and feasibility were excellent. PBA global rating scale scores in this population showed excellent construct validity as continuous (p < 0.001) and categorical (p = 0.001) variables. Concurrent validity of all metrics was poor against PBA score. Intrarater reliability was substantial for all parameters (intraclass correlation coefficient (ICC) > 0.8), and inter-rater reliability was substantial for LMD, MMD, TCA, and moderate (ICC 0.61 to 0.80) for MCS and TFCS. Assessment was time efficient compared to PBA. Conclusion. Assessment of technical skill in ankle fracture surgery using the first postoperative radiograph satisfies the tested Van der Vleuten’s utility criteria for effective assessment. 'Final product analysis' assessment may be useful to assess skill transfer in the simulation-based research setting. Cite this article: Bone Jt Open 2022;3(6):502–509


Bone & Joint Open
Vol. 1, Issue 9 | Pages 594 - 604
24 Sep 2020
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims. To develop a core outcome set of measurements from postoperative radiographs that can be used to assess technical skill in performing dynamic hip screw (DHS) and hemiarthroplasty, and to validate these against Van der Vleuten’s criteria for effective assessment. Methods. A Delphi exercise was undertaken at a regional major trauma centre to identify candidate measurement items. The feasibility of taking these measurements was tested by two of the authors (HKJ, GTRP). Validity and reliability were examined using the radiographs of operations performed by orthopaedic resident participants (n = 28) of a multicentre randomized controlled educational trial (ISRCTN20431944). Trainees were divided into novice and intermediate groups, defined as having performed < ten or ≥ ten cases each for DHS and hemiarthroplasty at baseline. The procedure-based assessment (PBA) global rating score was assumed as the gold standard assessment for the purposes of concurrent validity. Intra- and inter-rater reliability testing were performed on a random subset of 25 cases. Results. In total, 327 DHS and 248 hemiarthroplasty procedures were performed by 28 postgraduate year (PGY) 3 to 5 orthopaedic trainees during the 2014 to 2015 surgical training year at nine NHS hospitals in the West Midlands, UK. Overall, 109 PBAs were completed for DHS and 80 for hemiarthroplasty. Expert consensus identified four ‘final product analysis’ (FPA) radiological parameters of technical success for DHS: tip-apex distance (TAD); lag screw position in the femoral head; flushness of the plate against the lateral femoral cortex; and eight-cortex hold of the plate screws. Three parameters were identified for hemiarthroplasty: leg length discrepancy; femoral stem alignment; and femoral offset. Face validity, content validity, and feasibility were excellent. For all measurements, performance was better in the intermediate compared with the novice group, and this was statistically significant for TAD (p < 0.001) and femoral stem alignment (p = 0.023). Concurrent validity was poor when measured against global PBA score. This may be explained by the fact that they are measuring difference facets of competence. Intra-and inter-rater reliability were excellent for TAD, moderate for lag screw position (DHS), and moderate for leg length discrepancy (hemiarthroplasty). Use of a large multicentre dataset suggests good generalizability of the results to other settings. Assessment using FPA was time- and cost-effective compared with PBA. Conclusion. Final product analysis using post-implantation radiographs to measure technical skill in hip fracture surgery is feasible, valid, reliable, and cost-effective. It can complement traditional workplace-based assessment for measuring performance in the real-world operating room . It may have particular utility in competency-based training frameworks and for assessing skill transfer from the simulated to live operating theatre. Cite this article: Bone Joint Open 2020;1-9:594–604


Aims. Ankle fracture fixation is commonly performed by junior trainees. Simulation training using cadavers may shorten the learning curve and result in a technically superior surgical performance. Methods. We undertook a preliminary, pragmatic, single-blinded, multicentre, randomized controlled trial of cadaveric simulation versus standard training. Primary outcome was fracture reduction on postoperative radiographs. Results. Overall, 139 ankle fractures were fixed by 28 postgraduate year three to five trainee surgeons (mean age 29.4 years; 71% males) during ten months' follow-up. Under the intention-to-treat principle, a technically superior fixation was performed by the cadaveric-trained group compared to the standard-trained group, as measured on the first postoperative radiograph against predefined acceptability thresholds. The cadaveric-trained group used a lower intraoperative dose of radiation than the standard-trained group (mean difference 0.011 Gym. 2. , 95% confidence interval 0.003 to 0.019; p = 0.009). There was no difference in procedure time. Conclusion. Trainees randomized to cadaveric training performed better ankle fracture fixations and irradiated patients less during surgery compared to standard-trained trainees. This effect, which was previously unknown, is likely to be a consequence of the intervention. Further study is required. Cite this article: Bone Jt Open 2023;4(8):594–601


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 82 - 88
1 May 2024
Villa JM Rajschmir K Hosseinzadeh S Manrique-Succar J Grieco P Higuera-Rueda CA Riesgo AM

Aims. Large bone defects resulting from osteolysis, fractures, osteomyelitis, or metastases pose significant challenges in acetabular reconstruction for total hip arthroplasty. This study aimed to evaluate the survival and radiological outcomes of an acetabular reconstruction technique in patients at high risk of reconstruction failure (i.e. periprosthetic joint infection (PJI), poor bone stock, immunosuppressed patients), referred to as Hip Reconstruction In Situ with Screws and Cement (HiRISC). This involves a polyethylene liner embedded in cement-filled bone defects reinforced with screws and/or plates for enhanced fixation. Methods. A retrospective chart review of 59 consecutive acetabular reconstructions was performed by four surgeons in a single institution from 18 October 2018 to 5 January 2023. Cases were classified based on the Paprosky classification, excluding type 1 cases (n = 26) and including types 2 or 3 for analysis (n = 33). Radiological loosening was evaluated by an orthopaedic surgeon who was not the operating surgeon, by comparing the immediate postoperative radiographs with the ones at latest follow-up. Mean follow-up was 557 days (SD 441; 31 to 1,707). Results. Out of the 33 cases analyzed, six (18.2%) constructs required revision, with four revisions due to uncontrolled infection, one for dislocation, and one for aseptic loosening. Among the 27 non-revised constructs, only one showed wider radiolucencies compared to immediate postoperative radiographs, indicating potential loosening. Patients who underwent revision (n = 6) were significantly younger and had a higher BMI compared to those with non-revised constructs (p = 0.016 and p = 0.026, respectively). Sex, race, ethnicity, American Society of Anesthesiologists grade, infection status (patients with postoperative PJI diagnosis (septic) vs patients without such diagnosis (aseptic)), and mean follow-up did not significantly differ between revised and non-revised groups. Conclusion. The HiRISC technique may serve as a feasible short-term (about one to two years) alternative in patients with large acetabular defects, particularly in cases of PJI. Longer follow-up is necessary to establish the long-term survival of this technique. Cite this article: Bone Joint J 2024;106-B(5 Supple B):82–88


Bone & Joint 360
Vol. 13, Issue 4 | Pages 37 - 40
2 Aug 2024

The August 2024 Children’s orthopaedics Roundup. 360. looks at: Antibiotic prophylaxis and infection rates in paediatric supracondylar humerus fractures; Clinical consensus recommendations for the non-surgical treatment of children with Perthes’ disease in the UK; Health-related quality of life in idiopathic toe walkers: a multicentre prospective cross-sectional study; Children with spinal dysraphism: a systematic review of reported outcomes; No delay in age of crawling, standing, or walking with Pavlik harness treatment: a prospective cohort study; No value found with routine early postoperative radiographs after implant removal in paediatric patients; What do we know about the natural history of spastic hip dysplasia and pain in total-involvement cerebral palsy?; Evaluating the efficacy and safety of preoperative gallows traction for hip open reduction in infants


Bone & Joint Open
Vol. 4, Issue 12 | Pages 964 - 969
19 Dec 2023
Berwin JT Duffy SDX Gargan MF Barnes JR

Aims. We assessed the long-term outcomes of a large cohort of patients who have undergone a periacetabular osteotomy (PAO), and sought to validate a patient satisfaction questionnaire for use in a PAO cohort. Methods. All patients who had undergone a PAO from July 1998 to February 2013 were surveyed, with several patient-reported outcome measures (PROMs) and radiological measurements of preoperative acetabular dysplasia and postoperative correction also recorded. Patients were asked to rate their level of satisfaction with their operation in achieving pain relief, restoration of activities of daily living, ability to perform recreational activity, and their overall level of satisfaction with the procedure. Results. A total of 143 PAOs were performed between 1998 and 2013. Of those, 90 postoperative surveys were returned. Only 65 patients (73 hips) had both pre- and postoperative radiographs available for measurement. The mean time to follow-up was 15 years (6.5 to 20). Most patients were female (91%), with a mean age of 26.4 years (14.9 to 48.3) at the time of their surgery. A statistically significant improvement in radiological correction was detected in all hips (p < 0.001). A total of 67 patients (92.3%) remained either very satisfied or satisfied with their PAO. The internal consistency of the patient satisfaction questionnaire, measured using Cronbach’s α, ranged from 0.89 to 0.94 indicating ‘good’ to ‘excellent’ reliability. Conclusion. Outcomes of importance to patients undergoing a PAO include several key domains: pain relief, improve activities of daily living, and improve recreational ability. Our study demonstrates high rates of long-term patient satisfaction in all domains, and found the patient satisfaction questionnaire to be a valid and reliable instrument for use in this cohort. Cite this article: Bone Jt Open 2023;4(12):964–969


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 663 - 667
1 Jun 2023
Youn S Rhee SM Cho S Kim C Lee J Rhee YG

Aims. The aim of this study was to investigate the outcomes of arthroscopic decompression of calcific tendinitis performed without repairing the rotator cuff defect. Methods. A total of 99 patients who underwent treatment between December 2013 and August 2019 were retrospectively reviewed. Visual analogue scale (VAS) and American Shoulder and Elbow Surgeons (ASES) scores were reviewed pre- and postoperatively according to the location, size, physical characteristics, and radiological features of the calcific deposits. Additionally, the influence of any residual calcific deposits shown on postoperative radiographs was explored. The healing rate of the unrepaired cuff defect was determined by reviewing the 29 patients who had follow-up MRIs. Results. Statistically significant improvement from pre- to postoperation was seen in all VAS and ASES scores for each group, but no statistical differences were seen between the postoperative scores according to the differences in the features of the calcific deposits. When residual calcification was observed postoperatively, the mean ASES and VAS (rest) scores improved significantly to 95.0 (SD 5.6) and 0.0 (SD 0.0), respectively (p = 0.006 and p < 0.001), and did not differ from those who had the complete removal. Of 29 patients who had follow-up MRIs, six (20.7%) showed signs of an interstitial tear. This group’s mean postoperative ASES and VAS (rest) scores improved to excellent levels of 96.0 (SD 3.7) and 0.0 (SD 0.0), respectively, and were similar to those of the 23 patients with normal MRI appearances. Conclusion. Arthroscopic removal of calcific deposits without repairing the rotator cuff defect resulted in significant improvement in function and pain level, regardless of the deposit’s location, size, type, and whether or not complete excision was achieved. Despite leaving the defects unrepaired, in the limited number of patients with follow-up MRIs, 23 of 29 patients (79.3%) showed good healing, and the rest, who had persistent signs of interstitial defects on the MRIs, still had excellent outcomes. The removal of calcific deposits without repairing the cuff defects provided excellent outcomes. Cite this article: Bone Joint J 2023;105-B(6):663–667


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 215 - 219
1 Feb 2023
Buchan SJ Lindisfarne EA Stabler A Barry M Gent ED Bennet S Aarvold A

Aims. Fixation techniques used in the treatment of slipped capital femoral epiphysis (SCFE) that allow continued growth of the femoral neck, rather than inducing epiphyseal fusion in situ, have the advantage of allowing remodelling of the deformity. The aims of this study were threefold: to assess whether the Free-Gliding (FG) SCFE screw prevents further slip; to establish whether, in practice, it enables lengthening and gliding; and to determine whether the age of the patient influences the extent of glide. Methods. All patients with SCFE who underwent fixation using FG SCFE screws after its introduction at our institution, with minimum three years’ follow-up, were reviewed retrospectively as part of ongoing governance. All pre- and postoperative radiographs were evaluated. The demographics of the patients, the grade of slip, the extent of lengthening of the barrel of the screw and the restoration of Klein’s line were recorded. Subanalysis was performed according to sex and age. Results. A total of 19 hips in 13 patients were included. The mean age of the patients at the time of surgery was 11.5 years (9 to 13) and the mean follow-up was 63 months (45 to 83). A total of 13 FG SCFE screws were used for the fixation of mild or moderate SCFE, with six contralateral prophylactic fixations. No hip with SCFE showed a further slip after fixation and there were no complications. Lengthening occurred in 15 hips (79%), with a mean lengthening of the barrel of 6.8 mm (2.5 to 13.6) at final follow-up. Remodelling occurred in all hips with lengthening of the barrel. There was statistically more lengthening in patients who were aged < 12 years, regardless of sex (p = 0.002). Conclusion. The FG SCFE screw is effective in preventing further slip in patients with SCFE. Lengthening of the barrel occurred in most hips, and thus allowed remodelling. This was most marked in younger children, regardless of sex. Based on this study, this device should be considered for use in patients with SCFE aged < 12 years instead of standard pinning in situ. Cite this article: Bone Joint J 2023;105-B(2):215–219


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 26 - 26
2 Jan 2024
Jacob A Heumann M Zderic I Varga P Caspar J Lauterborn S Haschtmann D Fekete T Gueorguiev B Loibl M
Full Access

Stand-alone anterior lumbar interbody fusion (ALIF) provides the opportunity to avoid supplemental posterior fixation. This may reduce morbidity and complication rate, which is of special interest in patients with reduced bone mineral density (BMD). This study aims to assess immediate biomechanical stability and radiographic outcome of a stand-alone ALIF device with integrated screws in specimens of low BMD. Eight human cadaveric spines (L4-sacrum) were instrumented with SynFix-LR™ (DePuy Synthes) at L5/S1. Quantitative computed tomography was used to measure BMD of L5 in AMIRA. Threshold values proposed by the American Society of Radiology 80 and 120 mg CaHa/mL were used to differentiate between Osteoporosis, Osteopenia, and normal BMD. Segmental lordosis, anterior and posterior disc height were analysed on pre- and postoperative radiographs (Fig 1). Specimens were tested intact and following instrumentation using a flexibility protocol consisting of three loading cycles to ±7.5 Nm in flexion-extension, lateral bending, and axial rotation. The ranges of motion (ROM) of the index level were assessed using an optoelectronic system. BMD ranged 58–181mg CaHA/mL. Comparison of pre- and postoperative radiographs revealed significant increase of L5/S1 segmental lordosis (mean 14.6°, SD 5.1, p < 0.001) and anterior disc height (mean 5.8mm, SD 1.8, p < 0.001), but not posterior disc height. ROM of 6 specimens was reduced compared to the intact state. Two specimens showed destructive failure in extension. Mean decrease was most distinct in axial rotation up to 83% followed by flexion-extension. ALIF device with integrated screws at L5/S1 significantly increases segmental lordosis and anterior disc height without correlation to BMD. Primary stability in the immediate postoperative situation is mostly warranted in axial rotation. The risk of failure might be increased in extension for some patients with reduced lumbar BMD, therefore additional posterior stabilization could be considered. For any figures or tables, please contact the authors directly


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 929 - 937
1 Aug 2022
Gurung B Liu P Harris PDR Sagi A Field RE Sochart DH Tucker K Asopa V

Aims. Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are common orthopaedic procedures requiring postoperative radiographs to confirm implant positioning and identify complications. Artificial intelligence (AI)-based image analysis has the potential to automate this postoperative surveillance. The aim of this study was to prepare a scoping review to investigate how AI is being used in the analysis of radiographs following THA and TKA, and how accurate these tools are. Methods. The Embase, MEDLINE, and PubMed libraries were systematically searched to identify relevant articles. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for scoping reviews and Arksey and O’Malley framework were followed. Study quality was assessed using a modified Methodological Index for Non-Randomized Studies tool. AI performance was reported using either the area under the curve (AUC) or accuracy. Results. Of the 455 studies identified, only 12 were suitable for inclusion. Nine reported implant identification and three described predicting risk of implant failure. Of the 12, three studies compared AI performance with orthopaedic surgeons. AI-based implant identification achieved AUC 0.992 to 1, and most algorithms reported an accuracy > 90%, using 550 to 320,000 training radiographs. AI prediction of dislocation risk post-THA, determined after five-year follow-up, was satisfactory (AUC 76.67; 8,500 training radiographs). Diagnosis of hip implant loosening was good (accuracy 88.3%; 420 training radiographs) and measurement of postoperative acetabular angles was comparable to humans (mean absolute difference 1.35° to 1.39°). However, 11 of the 12 studies had several methodological limitations introducing a high risk of bias. None of the studies were externally validated. Conclusion. These studies show that AI is promising. While it already has the ability to analyze images with significant precision, there is currently insufficient high-level evidence to support its widespread clinical use. Further research to design robust studies that follow standard reporting guidelines should be encouraged to develop AI models that could be easily translated into real-world conditions. Cite this article: Bone Joint J 2022;104-B(8):929–937


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 743 - 750
1 Jul 2023
Fujii M Kawano S Ueno M Sonohata M Kitajima M Tanaka S Mawatari D Mawatari M

Aims. To clarify the mid-term results of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, combined with structural allograft bone grafting for severe hip dysplasia. Methods. We reviewed patients with severe hip dysplasia, defined as Severin IVb or V (lateral centre-edge angle (LCEA) < 0°), who underwent TOA with a structural bone allograft between 1998 and 2019. A medical chart review was conducted to extract demographic data, complications related to the osteotomy, and modified Harris Hip Score (mHHS). Radiological parameters of hip dysplasia were measured on pre- and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan–Meier product-limited method, and a multivariate Cox proportional hazard model was used to identify predictors for failure. Results. A total of 64 patients (76 hips) were included in this study. The median follow-up period was ten years (interquartile range (IQR) five to 14). The median mHHS improved from 67 (IQR 56 to 80) preoperatively to 96 (IQR 85 to 97) at the latest follow-up (p < 0.001). The radiological parameters improved postoperatively (p < 0.001), with the resulting parameters falling within the normal range in 42% to 95% of hips. The survival rate was 95% at ten years and 80% at 15 years. Preoperative Tönnis grade 2 was an independent risk factor for TOA failure. Conclusion. Our findings suggest that TOA with structural bone allografting is a viable surgical option for correcting severely dysplastic acetabulum in adolescents and young adults without advanced osteoarthritis, with favourable mid-term outcomes. Cite this article: Bone Joint J 2023;105-B(7):743–750


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 504 - 509
1 Apr 2022
Kennedy JW Farhan-Alanie OM Young D Kelly MP Young PS

Aims. The aim of this study was to assess the clinical and radiological outcomes of an antiprotrusio acetabular cage (APC) when used in the surgical treatment of periacetabular bone metastases. Methods. This retrospective cohort study using a prospectively collected database involved 56 patients who underwent acetabular reconstruction for periacetabular bone metastases or haematological malignancy using a single APC between January 2009 and 2020. The mean follow-up was 20 months (1 to 143). The primary outcome measure was implant survival. Postoperative radiographs were analyzed for loosening and failure. Patient and implant survival were assessed using a competing risk analysis. Secondary parameters included primary malignancy, oncological treatment, surgical factors, length of stay in hospital, and postoperative complications. Results. A total of 33 patients (59%) died during the study period at a mean of 15 months postoperatively (1 to 63). No patient had radiological evidence of loosening or failure. Acetabular component survival was 100%. Three patients (5.4%) had further surgery; one (1.8%) underwent revision of the femoral component for dislocation, one required debridement with implant retention for periprosthetic joint infection, and one required closed reduction for dislocation. Using death as a competing risk, at 100 months, the probability of revision was 0.036 and the risk of death was 0.84. Conclusion. With appropriate patient selection, the antiprotrusio cage offers good implant survival, with a reasonable perioperative complication rate in this high-risk group of patients when managing metastatic disease or haematological malignancy around the acetabulum. Cite this article: Bone Joint J 2022;104-B(4):504–509


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 435 - 441
1 May 2024
Angelomenos V Mohaddes M Kärrholm J Malchau H Shareghi B Itayem R

Aims. Refobacin Bone Cement R and Palacos R + G bone cement were introduced to replace the original cement Refobacin Palacos R in 2005. Both cements were assumed to behave in a biomechanically similar fashion to the original cement. The primary aim of this study was to compare the migration of a polished triple-tapered femoral stem fixed with either Refobacin Bone Cement R or Palacos R + G bone cement. Repeated radiostereometric analysis was used to measure migration of the femoral head centre. The secondary aims were evaluation of cement mantle, stem positioning, and patient-reported outcome measures. Methods. Overall, 75 patients were included in the study and 71 were available at two years postoperatively. Prior to surgery, they were randomized to one of the three combinations studied: Palacos cement with use of the Optivac mixing system, Refobacin with use of the Optivac system, and Refobacin with use of the Optipac system. Cemented MS30 stems and cemented Exceed acetabular components were used in all hips. Postoperative radiographs were used to assess the quality of the cement mantle according to Barrack et al, and the position and migration of the femoral stem. Harris Hip Score, Oxford Hip Score, Forgotten Joint Score, and University of California, Los Angeles Activity Scale were collected. Results. Median distal migration (y-axis) at two years for the Refobacin-Optivac system was -0.79 mm (-2.01 to -0.09), for the Refobacin-Optipac system was -0.75 mm (-2.16 to 0.20), and for the Palacos-Optivac system was -1.01 mm (-4.31 to -0.29). No statistically significant differences were found between the groups. Secondary outcomes did not differ statistically between the groups at the two-year follow-up. Conclusion. At two years, we found no significant differences in distal migration or clinical outcomes between the three groups. Our data indicate that Refobacin Bone Cement R and Palacos R + G are comparable in terms of stable fixation and early clinical outcomes. Cite this article: Bone Joint J 2024;106-B(5):435–441


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 39 - 39
10 Feb 2023
Lutter C Grupp T Mittelmeier W Selig M Grover P Dreischarf M Rose G Bien T
Full Access

Polyethylene wear represents a significant risk factor for the long-term success of knee arthroplasty [1]. This work aimed to develop and in vivo validate an automated algorithm for accurate and precise AI based wear measurement in knee arthroplasty using clinical AP radiographs for scientifically meaningful multi-centre studies. Twenty postoperative radiographs (knee joint AP in standing position) after knee arthroplasty were analysed using the novel algorithm. A convolutional neural network-based segmentation is used to localize the implant components on the X-Ray, and a 2D-3D registration of the CAD implant models precisely calculates the three-dimensional position and orientation of the implants in the joint at the time of acquisition. From this, the minimal distance between the involved implant components is determined, and its postoperative change over time enables the determination of wear in the radiographs. The measured minimum inlay height of 335 unloaded inlays excluding the weight-induced deformation, served as ground truth for validation and was compared to the algorithmically calculated component distances from 20 radiographs. With an average weight of 94 kg in the studied TKA patient cohort, it was determined that an average inlay height of 6.160 mm is expected in the patient. Based on the radiographs, the algorithm calculated a minimum component distance of 6.158 mm (SD = 81 µm), which deviated by 2 µm in comparison to the expected inlay height. An automated method was presented that allows accurate and precise determination of the inlay height and subsequently the wear in knee arthroplasty based on a clinical radiograph and the CAD models. Precision and accuracy are comparable to the current gold standard RSA [2], but without relying on special radiographic setups. The developed method can therefore be used to objectively investigate novel implant materials with meaningful clinical cohorts, thus improving the quality of patient care


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 8 - 8
17 Jun 2024
Aamir J Caldwell R Long S Sreenivasan S Mayrotas J Panera A Jeevaresan S Mason L
Full Access

Background. Many approaches to management of medial malleolar fractures are described in the literature however, their morphology is under investigated. The aim of this study was to analyse the morphology of medial malleolar fractures to identify any association with medial malleolar fracture non-union or malunion. Methods. Patients who had undergone surgical fixation of their MMF were identified from 2012 to 2022, using electronic patient records in a single centre. Analysis of their preoperative, intraoperative, and postoperative radiographs was performed to determine their morphology and prevalence of non-union and malunion. Lauge-Hansen classification was used to characterise ankle fracture morphology and Herscovici classification to characterise MMF morphology. Results. A total of 650 patients were identified across a 10-year period which could be included in the study. The overall non-union rate for our cohort was 18.77% (122/650). The overall malunion rate was 6.92% (45/650). There was no significant difference in union rates across the Herscovici classification groups. Herscovici type A fractures were significantly more frequently malreduced at time of surgery as compared to other fracture types (p=.003). Medial wall blowout combined with Hercovici type B fractures showed a significant increase in malunion rate. There is a higher rate of bone union in patients who have been anatomically reduced. Conclusion. The morphology of medial malleolar fractures does have an impact of the radiological outcome following surgical management. Medial wall blowout fractures were most prevalent in adduction-type injuries; however, it should not be ruled out in rotational injuries with medial wall blowouts combined with and Herscovici type B fractures showing a significant increase in malunions. Herscovici type A fractures had significantly higher malreductions however the clinical implications of mal reducing small avulsions is unknown


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 16 - 16
23 Apr 2024
Murray E Connaghan J Creavin K Egglestone A Jamal B
Full Access

Introduction. By utilising the inherent variability achievable with circular frames, surgeons can manage a wide spectrum of complex injuries, and can deal with deformity at multiple levels, in multiple planes. The aim of this study was to assess functional outcomes utilising patients reported outcome measures (PROMs) of patients being treated with circular (Ilizarov) frame fixation for complex lower limb injuries and assess these results in conjunction with the observed postoperative alignment of the patients’ limbs. Materials & Methods. Cases were identified using a prospectively collected database of adult patients presenting between July 2018 and August 2021. Functional outcomes were assessed using the American Orthopaedic Foot and Ankle Score (AOFAS), the 5-level EQ-5D (EQ5D5L), the Lysholm Knee Scoring Scale (LKSS), the Olerud-Molendar Ankle Score (OMAS), and the Tegner Activity Scale (TAS). Postoperative radiographs were analysed for fracture union and to quantify malunion (as described in Dror Paleys Principles of Deformity Correction). Results. The mean AOFAS, EQ5D5L, LKSS and OMAS scores showed an initial drop from pre-op to early time points and then steady increase over the early, mid, late and frame-off time points, with a resultant score higher than pre-op. Malunion was found in 35 (41.7%) patients, 7 patients had a malunion within 5 degrees of normal, 15 from 5–10 degrees of normal, 12 from 10–15 degrees of normal and 2 out with 15 degrees of normal. Conclusions. Circular frame fixation is an attractive option in complex lower limb trauma where alternative fixation methods are unsuitable. Whilst post-operative success to the surgeon might be determined radiographically, patient reported outcomes give a functionally important, objective measure of the success of the surgery to the patient


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 783 - 791
1 Aug 2024
Tanaka S Fujii M Kawano S Ueno M Nagamine S Mawatari M

Aims. The aim of this study was to determine the clinical outcomes and factors contributing to failure of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, for advanced osteoarthritis secondary to hip dysplasia. Methods. We reviewed patients with Tönnis grade 2 osteoarthritis secondary to hip dysplasia who underwent TOA between November 1998 and December 2019. Patient demographic details, osteotomy-related complications, and the modified Harris Hip Score (mHHS) were obtained via medical notes review. Radiological indicators of hip dysplasia were assessed using preoperative and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan-Meier product-limited method. A multivariate Cox proportional hazards model was used to identify predictors of failure. Results. This study included 127 patients (137 hips). Median follow-up period was ten years (IQR 6 to 15). The median mHHS improved from 59 (IQR 52 to 70) preoperatively to 90 (IQR 73 to 96) at the latest follow-up (p < 0.001). The survival rate was 90% (95% CI 82 to 95) at ten years, decreasing to 21% (95% CI 7 to 48) at 20 years. Fair joint congruity on preoperative hip abduction radiographs and a decreased postoperative anterior wall index (AWI) were identified as independent risk factors for failure. The survival rate for the 42 hips with good preoperative joint congruity and a postoperative AWI ≥ 0.30 was 100% at ten years, and remained at 83% (95% CI 38 to 98) at 20 years. Conclusion. Although the overall clinical outcomes of TOA in patients with advanced osteoarthritis are suboptimal, favourable results can be achieved in selected cases with good preoperative joint congruity and adequate postoperative anterior acetabular coverage. Cite this article: Bone Joint J 2024;106-B(8):783–791


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 182 - 188
1 Feb 2024
Gallego JA Rotman D Watts AC

Aims. Acute and chronic injuries of the interosseus membrane can result in longitudinal instability of the forearm. Reconstruction of the central band of the interosseus membrane can help to restore biomechanical stability. Different methods have been used to reconstruct the central band, including tendon grafts, bone-ligament-bone grafts, and synthetic grafts. This Idea, Development, Exploration, Assessment, and Long-term (IDEAL) phase 1 study aims to review the clinical results of reconstruction using a synthetic braided cross-linked graft secured at either end with an Endobutton to restore the force balance between the bones of the forearm. Methods. An independent retrospective review was conducted of a consecutive series of 21 patients with longitudinal instability injuries treated with anatomical central band reconstruction between February 2011 and July 2019. Patients with less than 12 months’ follow-up or who were treated acutely were excluded, leaving 18 patients in total. Preoperative clinical and radiological assessments were compared with prospectively gathered data using range of motion and the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) functional outcome score. Results. Of the 18 patients (nine male, nine female) who met the inclusion criteria, the median follow-up was 8.5 years (interquartile range (IQR) 5.6 to 10). Their mean age was 49 years (SD 11). The mean extension improved significantly from 38° (SD 15°) to 24° (SD 9°) (p = 0.027), with a mean flexion-extension arc change from 81° (SD 27°) to 93° (SD 30°) (p = 0.172) but with no forearm rotational improvement (p = 0.233) at latest follow-up. The QuickDASH functional score improved significantly from 80 (SD 14) to 52 (SD 26) following reconstruction (p = 0.031), but generally the level of disability remains high. Radiological assessment showed no progression of proximal migration of the radius, with a stable interbutton distance and ulnar variance from immediate postoperative radiograph to the latest follow-up. Conclusion. Central band interosseus membrane reconstruction using a synthetic braided cross-linked graft can improve patient-rated arm function and range of motion, but significant functional deficits remain in patients with chronic injuries. Cite this article: Bone Joint J 2024;106-B(2):182–188


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 57 - 57
1 Mar 2021
Sanders E Dobransky J Finless A Adamczyk A Wilkin G Liew A Gofton W Papp S Beaulé P Grammatopoulos G
Full Access

Management of acetabular fractures in the elderly population remains somewhat controversial in regards to when to consider is open reduction internal fixation (ORIF) versus acute primary total hip. study aims to (1) describe outcome of this complex problem and investigate predictors of successful outcome. This retrospective study analyzes all acetabular fractures in patients over the age of 60, managed by ORIF at a tertiary trauma care centre between 2007 and 2018 with a minimum follow up of one year. Of the 117 patients reviewed, 85 patients undergoing ORIF for treatment of their acetabular fracture were included in the analysis. The remainder were excluded based management option including acute ORIF with THA (n=10), two-stage ORIF (n=2), external fixator only (n=1), acute THA (n=1), and conservative management (n=1). The remainder were excluded based on inaccessible medical records (n=6), mislabelled diagnosis (n=6), associated femoral injuries (n=4), acetabular fracture following hemiarthroplasty (n=1). The mean age of the cohort is 70±7 years old with 74% (n=62) of patients being male. Data collected included: demographics, mechanism of injury, Charlson Comorbidity Index (CCI), ASA Grade, smoking status and reoperations. Pre-Operative Radiographs were analyzed to determine the Judet and Letournel fracture pattern, presence of comminution and posterior wall marginal impaction. Postoperative radiographs were used to determine Matta Grade of Reduction. Outcome measures included morbidity-, mortality- rates, joint survival, radiographic evidence of osteoarthritis and patient reported outcome measures (PROMs) using the Oxford Hip Score (OHS) at follow-up. A poor outcome in ORIF was defined as one of the following: 1) conversion to THA or 2) the presence of radiographic OA, combined with an OHS less than 34 (findings consistent with a hip that would benefit from a hip replacement). The data was analyzed step-wise to create a regression model predictive of outcome following ORIF. Following ORIF, 31% (n=26) of the cohort had anatomic reduction, while 64% (n=54) had imperfect or poor reduction. 4 patients did not have adequate postoperative radiographs to assess the reduction. 31 of 84 patients undergoing ORIF had a complication of which 22.6% (n=19) required reoperation. The most common reason being conversion to THA (n=14), which occurred an average of 1.6±1.9 years post-ORIF. The remainder required reoperation for infection (n=5). Including those converted to THA, 43% (n=36) developed radiographic OA following acetabular fracture management. The mean OHS in patients undergoing ORIF was 36 ± 10; 13(16%) had an OHS less than 34. The results of the logistic regression demonstrate that Matta grade of reduction (p=0.017), to be predictive of a poor outcome in acetabular fracture management. With non-anatomic alignment following fixation, patients had a 3 times greater risk of a poor outcome. No other variables were found to be predictive of ORIF outcome. The ability to achieve anatomic reduction of fracture fragments as determined by the Matta grade, is predictive of the ability to retain the native hip with acceptable outcome following acetabular fracture in the elderly. Further research must be conducted to determine predictors of adequate reduction in order to identify candidates for ORIF


Bone & Joint Open
Vol. 4, Issue 8 | Pages 602 - 611
21 Aug 2023
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims. To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture. Methods. This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty). Results. Eight female (29%) and 20 male trainees (71%), mean age 29.4 years, performed 317 DHS operations and 243 hemiarthroplasties during ten months of follow-up. Primary analysis was a random effect model with surgeon-level fixed effects of patient condition, patient age, and surgeon experience, with a random intercept for surgeon. Under the intention-to-treat principle, for hemiarthroplasty there was better implant position in favour of cadaveric training, measured by leg length discrepancy ≤ 10 mm (odds ratio (OR) 4.08 (95% confidence interval (CI) 1.17 to 14.22); p = 0.027). There were significantly fewer postoperative blood transfusions required in patients undergoing hemiarthroplasty by cadaveric-trained compared to standard-trained surgeons (OR 6.00 (95% CI 1.83 to 19.69); p = 0.003). For DHS, there was no significant between-group difference in implant position as measured by tip-apex distance ≤ 25 mm (OR 6.47 (95% CI 0.97 to 43.05); p = 0.053). No between-group differences were observed for any secondary clinical outcomes. Conclusion. Trainees randomized to additional cadaveric training performed hip fracture fixation with better implant positioning and fewer postoperative blood transfusions in hemiarthroplasty. This effect, which was previously unknown, may be a consequence of the intervention. Further study is required. Cite this article: Bone Jt Open 2023;4(8):602–611


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 23 - 23
1 Oct 2020
Bechtold D Schwabe M Lawrie C Clohisy JC
Full Access

Introduction. The direct anterior approach (DAA) for total hip arthroplasty (THA) has gained popularity in recent years. Potential advantages over other surgical approaches include less postoperative pain, fewer postoperative precautions, and quicker early recovery. It is most commonly performed in the supine position with traction tables or table mounted bone hooks to facilitate exposure. In this study, we describe a reproducible surgical technique for DAA THA in the lateral decubitus position with use of standard THA equipment and report on our results and learning curve. Methods. A prospectively collected hip repository was queried for all primary THA DAA performed in the lateral position by a single surgeon over a 4-year period from the surgeon's first case utilizing the technique. Retrospective chart review was performed to identify complications and revisions. Modified Harris Hip Score (mHHS) was collected pre-operatively and again at 1-year post-operative. Radiographic parameters including were measured on the 1-year postoperative radiographs. Results. Three hundred forty-one hips were identified in patients over 18 years of age with 337 hips meeting our inclusion/exclusion criteria. A total of 257 hips (76%) had a minimum of 1-year follow-up. 212 of 225 hips (94%) with available mHHS data achieved MCID, defined as mHHS change of > 8. Mean surgical time was 88 ± 16 minutes. Radiographic evaluation demonstrated reproducible results with mean radiographic side to side leg length discrepancy of 2.6 ± 5.9mm and femoral offset difference of 0.2 ± 4.9mm. Among patients with adequate postoperative radiographs, 234 of 243 (96%) had acetabular component positions within Lewinnick's safe zone. 3 hips (0.9%) required revision THA within the first year postoperatively. There were no dislocations and there was no learning curve detected in terms of operative time, blood loss, complication rate or acetabular component position. Discussion. Critics of DAA THA cite its long learning curve with increased risk of complications as an argument against its widespread use. In this study, we have described a safe and efficient technique for performing THA via the DAA in the familiar lateral decubitus with the use of a standard operating table, positioning devices and THA instrumentation. Our results demonstrate excellent acetabular component placement and low rates of complications within the first postoperative year. Conclusion. DAA THA can be performed safely and efficiently in the lateral decubitus position without a specialized table or instrumentation. Surgeon familiarity with patient position and instruments using the technique presented here may be associated with a shorter procedural learning curve


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 598 - 603
1 May 2022
Siljander MP Gausden EB Wooster BM Karczewski D Sierra RJ Trousdale RT Abdel MP

Aims. The aim of this study was to evaluate the incidence of liner malseating in two commonly used dual-mobility (DM) designs. Secondary aims included determining the risk of dislocation, survival, and clinical outcomes. Methods. We retrospectively identified 256 primary total hip arthroplasties (THAs) that included a DM component (144 Stryker MDM and 112 Zimmer-Biomet G7) in 233 patients, performed between January 2012 and December 2019. Postoperative radiographs were reviewed independently for malseating of the liner by five reviewers. The mean age of the patients at the time of THA was 66 years (18 to 93), 166 (65%) were female, and the mean BMI was 30 kg/m. 2. (17 to 57). The mean follow-up was 3.5 years (2.0 to 9.2). Results. Three liners (1.2%) were malseated, including two MDMs (1.4%) and one G7 (0.9%). No clinical consequence was identified from malseating. The five-year survival free of dislocation was 97.1%, including two DM and one intraprosthetic dislocation. The five-year survival free of revision was 95.4%, with seven revisions. The mean Harris Hip Scores increased from 46 (24 to 69) preoperatively to 81 (40 to 100) at two years postoperatively (p < 0.001). Conclusion. The incidence of DM liner malseating after primary THA was low, with no known clinical consequences at mid-term follow-up. Malseating is not exclusive of design, and these findings emphasize the importance of careful evaluation of the liner after impaction to avoid this complication. Cite this article: Bone Joint J 2022;104-B(5):598–603


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 610 - 618
1 Apr 2021
Batailler C Bordes M Lording T Nigues A Servien E Calliess T Lustig S

Aims. Ideal component sizing may be difficult to achieve in unicompartmental knee arthroplasty (UKA). Anatomical variants, incremental implant size, and a reduced surgical exposure may lead to over- or under-sizing of the components. The purpose of this study was to compare the accuracy of UKA sizing with robotic-assisted techniques versus a conventional surgical technique. Methods. Three groups of 93 medial UKAs were assessed. The first group was performed by a conventional technique, the second group with an image-free robotic-assisted system (Image-Free group), and the last group with an image-based robotic arm-assisted system, using a preoperative CT scan (Image-Based group). There were no demographic differences between groups. We compared six parameters on postoperative radiographs to assess UKA sizing. Incorrect sizing was defined by an over- or under-sizing greater than 3 mm. Results. There was a higher rate of tibial under-sizing posteriorly in the conventional group compared to robotic-assisted groups (47.3% (n = 44) in conventional group, 29% (n = 27) in Image-Free group, 6.5% (n = 6) in Image-Based group; p < 0.001), as well as a higher rate of femoral under-sizing posteriorly (30.1% (n = 28) in conventional group, 7.5% (n = 7) in Image-Free group, 12.9% (n = 12) in Image-Based group; p < 0.001). The posterior femoral offset was more often increased in the conventional group, especially in comparison to the Image-Based group (43% (n = 40) in conventional group, 30.1% (n = 28) in Image-Free group, 8.6% (n = 8) in Image-Based group; p < 0.001). There was no significant overhang of the femoral or tibial implant in any groups. Conclusion. Robotic-assisted surgical techniques for medial UKA decrease the risk of tibial and femoral under-sizing, particularly with an image-based system using a preoperative CT scan. Cite this article: Bone Joint J 2021;103-B(4):610–618


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1280 - 1288
1 Oct 2018
Grammatopoulos G Gofton W Cochran M Dobransky J Carli A Abdelbary H Gill HS Beaulé PE

Aims. This study aims to: determine the difference in pelvic position that occurs between surgery and radiographic, supine, postoperative assessment; examine how the difference in pelvic position influences subsequent component orientation; and establish whether differences in pelvic position, and thereafter component orientation, exist between total hip arthroplasties (THAs) performed in the supine versus the lateral decubitus positions. Patients and Methods. The intra- and postoperative anteroposterior pelvic radiographs of 321 THAs were included; 167 were performed with the patient supine using the anterior approach and 154 were performed with the patient in the lateral decubitus using the posterior approach. The inclination and anteversion of the acetabular component was measured and the difference (Δ) between the intra- and postoperative radiographs was determined. The target zone was inclination/anteversion of 40°/20° (± 10°). Changes in the tilt, rotation, and obliquity of the pelvis on the intra- and postoperative radiographs were calculated from Δinclination/anteversion using the Levenberg–Marquardt algorithm. Results. The mean postoperative inclination/anteversion was 40° (± 8°)/23° (± 9°) with Δinclination and/or Δanteversion > ± 10° in 74 (21%). Intraoperatively, the pelvis was anteriorly tilted by a mean of 4° (± 10°), internally rotated by a mean of 1° (± 10°) and adducted by a mean of 1° (± 5°). Having Δinclination and/or Δanteversion > ± 10° was associated with a 3.5 odds ratio of having the acetabular component outside the target zone. A greater proportion of THAs that were undertaken with the patient in the lateral decubitus position had Δinclination and/or Δanteversion > ± 10° (35.3%, 54/153) compared with those in the supine position (4.8%, 8/167; p < 0.001). A greater number of acetabular components were within the target zone in THAs undertaken with the patient in the supine position (72%, 120/167), compared with those in the lateral decubitus position (44%, 67/153; p < 0.001). Intraoperatively, the pelvis was more anteriorly tilted (p < 0.001) and more internally rotated (p = 0.04) when the patient was in the lateral decubitus position. Conclusion. The pelvic position is more reliable when the patient is in the supine position, leading to more consistent orientation of the acetabular component. Significant differences in pelvic tilt and rotation are seen with the patient in the lateral decubitus position. Cite this article: Bone Joint J 2018;100-B:1280–8


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 536 - 541
1 Mar 2021
Ferlic PW Hauser L Götzen M Lindtner RA Fischler S Krismer M

Aims. The aim of this retrospective study was to compare the correction achieved using a convex pedicle screw technique and a low implant density achieved using periapical concave-sided screws and a high implant density. We hypothesized that there would be no difference in outcome between the two techniques. Methods. We retrospectively analyzed a series of 51 patients with a thoracic adolescent idiopathic scoliosis. There were 26 patients in the convex pedicle screw group who had screws implanted periapically (Group 2) and a control group of 25 patients with bilateral pedicle screws (Group 1). The patients’ charts were reviewed and pre- and postoperative radiographs evaluated. Postoperative patient-reported outcome measures (PROMs) were recorded. Results. The number of implants (14.5 vs 17.1) and the implant density (1.5 vs 1.9) were significantly lower in Group 2 (p < 0.001). Operating time was 27 minutes shorter in Group 2 than in Group 1, with a mean of 217 minutes (SD 50.5; 120 to 346). The duration of surgery per instrumented vertebra was reduced by 19% in Group 2 (p = 0.011). No statistical difference was found in the postoperative Cobb angle, vertebral rotation, the relative correction achieved, or postoperative PROMs. Conclusion. Despite a lower implant density and achieving correction through a convex rod, surgical correction of the Cobb angle and vertebral body rotation was similar in both groups. Periapical pedicle screws and primary correction on the concave side do not seem to be mandatory in order to achieve good surgical results in idiopathic thoracic scoliosis. The operating time was shorter in the group with lower implant density. In conclusion, the technique provided good results and has the potential to reduce complications and costs. Cite this article: Bone Joint J 2021;103-B(3):536–541


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1339 - 1344
1 Aug 2021
Jain S Mohrir G Townsend O Lamb JN Palan J Aderinto J Pandit H

Aims. This aim of this study was to assess the reliability and validity of the Unified Classification System (UCS) for postoperative periprosthetic femoral fractures (PFFs) around cemented polished taper-slip (PTS) stems. Methods. Radiographs of 71 patients with a PFF admitted consecutively at two centres between 25 February 2012 and 19 May 2020 were collated by an independent investigator. Six observers (three hip consultants and three trainees) were familiarized with the UCS. Each PFF was classified on two separate occasions, with a mean time between assessments of 22.7 days (16 to 29). Interobserver reliability for more than two observers was assessed using percentage agreement and Fleiss’ kappa statistic. Intraobserver reliability between two observers was calculated with Cohen kappa statistic. Validity was tested on surgically managed UCS type B PFFs where stem stability was documented in operation notes (n = 50). Validity was assessed using percentage agreement and Cohen kappa statistic between radiological assessment and intraoperative findings. Kappa statistics were interpreted using Landis and Koch criteria. All six observers were blinded to operation notes and postoperative radiographs. Results. Interobserver reliability percentage agreement was 58.5% and the overall kappa value was 0.442 (moderate agreement). Lowest kappa values were seen for type B fractures (0.095 to 0.360). The mean intraobserver reliability kappa value was 0.672 (0.447 to 0.867), indicating substantial agreement. Validity percentage agreement was 65.7% and the mean kappa value was 0.300 (0.160 to 0.4400) indicating only fair agreement. Conclusion. This study demonstrates that the UCS is unsatisfactory for the classification of PFFs around PTS stems, and that it has considerably lower reliability and validity than previously described for other stem types. Radiological PTS stem loosening in the presence of PFF is poorly defined and formal intraoperative testing of stem stability is recommended. Cite this article: Bone Joint J 2021;103-B(8):1339–1344


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 107 - 107
1 Nov 2021
Salini V
Full Access

Treatment of large bone defects represents a great challenge for orthopedic surgeons. The main causes are congenital abnormalities, traumas, osteomyelitis and bone resection due to cancer. Each surgical method for bone reconstruction leads its own burden of complications. The gold standard is considered the autologous bone graft, either of cancellous or cortical origin, but due to graft resorption and a limitation for large defect, allograft techniques have been identified. In the bone defect, these include the placement of cadaver bone or cement spacer to create the ‘Biological Chamber’ to restore bone regeneration, according to the Masquelet technique. We report eight patients, with large bone defect (for various etiologies and with an average size defect of 13.3 cm) in the lower and upper limbs, who underwent surgery at our Traumatology Department, between January 2019 and October 2020. Three patients were treated with both cortical and cancellous autologous bone grafts, while five received cortical or cement spacer allografts from donors. They underwent pre and postoperative radiographs and complete osseointegration was observed in all patients already undergoing monthly radiographic checks, with a restoration of length and range of motion. In our study, both the two stage-Masquelet and the cortical bone graft from a cadaver donor proved to be valid techniques in patients with very extensive defects to reconstruct the defect, restore the length, minimize implant left in situ and achieve complete functional recovery


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 48 - 48
1 Oct 2019
Anderson L Erickson J Peters CL
Full Access

Introduction. Radiographic assessment of acetabular fragment positioning during periacetabular osteotomy (PAO) is of paramount importance. Plain radiographic examination is time and resource intensive. Fluoroscopic based assessment is increasingly utilized but can introduce distortion. Our purpose was to determine the correlation of intraoperative fluoroscopy-based measurements with a fluoroscopic tool that corrects for distortion with postoperative plain-film measurements. Methods. We performed a prospective validation study on 32 PAO's (28 patients) performed by a single academic surgeon. Preoperative standing radiographs, intraoperative fluoroscopic images, and postoperative standing radiographs were evaluated with lateral center edge angle (LCEA), acetabular index (AI), posterior wall sign (PWS), and anterior center edge angle (ACEA). Intraoperative fluoroscopy was adjusted to account for pelvic inclination. The fluoroscopic GRID was utilized in all cases (Phantom MSK Hip Preservation, OrthoGrid LLC, Salt Lake City, UT). Intraoperative fluoroscopic measurements were compared to preoperative and postoperative standing radiographs at 6 weeks using linear regression applied in MINITAB. Results. All pre and post-correction measurements demonstrated excellent agreement within an average difference of 1.2 and 0.9 degrees (deg) respectively (p<0.01). Agreement between post-correction fluoroscopic GRID measurements and 6-week postoperative radiographs was: average difference for LCEA −0.4 deg (range −5 to 8 deg, SD 3.4), −0.9 deg for ACEA (range −16 to 7 deg, SD 5.1), and 0.3 deg for AI (range −8 to 6 deg, SD 3.3) (all p<.01). The PWS agreement was 93%. There was a tendency for fluoroscopic GRID measurements to underestimate acetabular coverage by less than 1 degree. Conclusion. Our study validated the use of a novel intraoperative fluoroscopic tool that accounts for fluoroscopic distortion and permits real-time measurements of PAO fragment correction that correlate accurately with postoperative evaluation. We believe that this tool adds value by giving surgeons reliable quantitative measurements of correction without interfering with surgical work-flow. For any tables or figures, please contact the authors directly


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 872 - 880
1 May 2021
Young PS Macarico DT Silverwood RK Farhan-Alanie OM Mohammed A Periasamy K Nicol A Meek RMD

Aims. Uncemented metal acetabular components show good osseointegration, but material stiffness causes stress shielding and retroacetabular bone loss. Cemented monoblock polyethylene components load more physiologically; however, the cement bone interface can suffer fibrous encapsulation and loosening. It was hypothesized that an uncemented titanium-sintered monoblock polyethylene component may offer the optimum combination of osseointegration and anatomical loading. Methods. A total of 38 patients were prospectively enrolled and received an uncemented monoblock polyethylene acetabular (pressfit) component. This single cohort was then retrospectively compared with previously reported randomized cohorts of cemented monoblock (cemented) and trabecular metal (trabecular) acetabular implants. The primary outcome measure was periprosthetic bone density using dual-energy x-ray absorptiometry over two years. Secondary outcomes included radiological and clinical analysis. Results. Although there were differences in the number of males and females in each group, no significant sex bias was noted (p = 0.080). Furthermore, there was no significant difference in age (p = 0.910) or baseline lumbar bone mineral density (BMD) (p = 0.998) found between any of the groups (pressfit, cemented, or trabecular). The pressfit implant initially behaved like the trabecular component with an immediate fall in BMD in the inferior and medial regions, with preserved BMD laterally, suggesting lateral rim loading. However, the pressfit component subsequently showed a reversal in BMD medially with recovery back towards baseline, and a continued rise in lateral BMD. This would suggest that the pressfit component begins to reload the medial bone over time, more akin to the cemented component. Analysis of postoperative radiographs revealed no pressfit component subsidence or movement up to two years postoperatively (100% interobserver reliability). Medial defects seen immediately postoperatively in five cases had completely resolved by two years in four patients. Conclusion. Initially, the uncemented monoblock component behaved similarly to the rigid trabecular metal component with lateral rim loading; however, over two years this changed to more closely resemble the loading pattern of a cemented polyethylene component with increasing medial pelvic loading. This indicates that the uncemented monoblock acetabular component may result in optimized fixation and preservation of retroacetabular bone stock. Cite this article: Bone Joint J 2021;103-B(5):872–880


Bone & Joint Open
Vol. 3, Issue 6 | Pages 475 - 484
13 Jun 2022
Jang SJ Vigdorchik JM Windsor EW Schwarzkopf R Mayman DJ Sculco PK

Aims. Navigation devices are designed to improve a surgeon’s accuracy in positioning the acetabular and femoral components in total hip arthroplasty (THA). The purpose of this study was to both evaluate the accuracy of an optical computer-assisted surgery (CAS) navigation system and determine whether preoperative spinopelvic mobility (categorized as hypermobile, normal, or stiff) increased the risk of acetabular component placement error. Methods. A total of 356 patients undergoing primary THA were prospectively enrolled from November 2016 to March 2018. Clinically relevant error using the CAS system was defined as a difference of > 5° between CAS and 3D radiological reconstruction measurements for acetabular component inclination and anteversion. Univariate and multiple logistic regression analyses were conducted to determine whether hypermobile (. Δ. sacral slope(SS). stand-sit. > 30°), or stiff (. ∆. SS. stand-sit. < 10°) spinopelvic mobility contributed to increased error rates. Results. The paired absolute difference between CAS and postoperative imaging measurements was 2.3° (standard deviation (SD) 2.6°) for inclination and 3.1° (SD 4.2°) for anteversion. Using a target zone of 40° (± 10°) (inclination) and 20° (± 10°) (anteversion), postoperative standing radiographs measured 96% of acetabular components within the target zone for both inclination and anteversion. Multiple logistic regression analysis controlling for BMI and sex revealed that hypermobile spinopelvic mobility significantly increased error rates for anteversion (odds ratio (OR) 2.48, p = 0.009) and inclination (OR 2.44, p = 0.016), whereas stiff spinopelvic mobility increased error rates for anteversion (OR 1.97, p = 0.028). There were no dislocations at a minimum three-year follow-up. Conclusion. Despite high reliability in acetabular positioning for inclination in a large patient cohort using an optical CAS system, hypermobile and stiff spinopelvic mobility significantly increased the risk of clinically relevant errors. In patients with abnormal spinopelvic mobility, CAS systems should be adjusted for use to avoid acetabular component misalignment and subsequent risk for long-term dislocation. Cite this article: Bone Jt Open 2022;3(6):475–484


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 338 - 346
1 Feb 2021
Khow YZ Liow MHL Lee M Chen JY Lo NN Yeo SJ

Aims. This study aimed to identify the tibial component and femoral component coronal angles (TCCAs and FCCAs), which concomitantly are associated with the best outcomes and survivorship in a cohort of fixed-bearing, cemented, medial unicompartmental knee arthroplasties (UKAs). We also investigated the potential two-way interactions between the TCCA and FCCA. Methods. Prospectively collected registry data involving 264 UKAs from a single institution were analyzed. The TCCAs and FCCAs were measured on postoperative radiographs and absolute angles were analyzed. Clinical assessment at six months, two years, and ten years was undertaken using the Knee Society Knee score (KSKS) and Knee Society Function score (KSFS), the Oxford Knee Score (OKS), the 36-Item Short-Form Health Survey questionnaire (SF-36), and range of motion (ROM). Fulfilment of expectations and satisfaction was also recorded. Implant survivorship was reviewed at a mean follow-up of 14 years (12 to 16). Multivariate regression models included covariates, TCCA, FCCA, and two-way interactions between them. Partial residual graphs were generated to identify angles associated with the best outcomes. Kaplan-Meier analysis was used to compare implant survivorship between groups. Results. Significant two-way interaction effects between TCCA and FCCA were identified. Adjusted for each other and their interaction, a TCCA of between 2° and 4° and a FCCA of between 0° and 2° were found to be associated with the greatest improvements in knee scores and the probability of fulfilling expectations and satisfaction at ten years. Patients in the optimal group whose TCCA and FCCA were between 2° and 4°, and 0° and 2°, respectively, had a significant survival benefit at 15 years compared with the non-optimal group (optimal: survival = 100% vs non-optimal: survival = 92%, 95% confidence interval (CI) 88% to 96%). Conclusion. Significant two-way interactions between the TCCA and FCCA demonstrate the importance of evaluating the alignment of the components concomitantly in future studies. By doing so, we found that patients who concomitantly had both a TCCA of between 2° and 4° and a FCCA of between 0° and 2° had the best patient-reported outcome measures at ten years and better survivorship at 15 years. Cite this article: Bone Joint J 2021;103-B(2):338–346


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1689 - 1696
1 Dec 2020
Halai MM Pinsker E Mann MA Daniels TR

Aims. Preoperative talar valgus deformity ≥ 15° is considered a contraindication for total ankle arthroplasty (TAA). We compared operative procedures and clinical outcomes of TAA in patients with talar valgus deformity ≥ 15° and < 15°. Methods. A matched cohort of patients similar for demographics and components used but differing in preoperative coronal-plane tibiotalar valgus deformity ≥ 15° (valgus, n = 50; 52% male, mean age 65.8 years (SD 10.3), mean body mass index (BMI) 29.4 (SD 5.2)) or < 15° (control, n = 50; 58% male, mean age 65.6 years (SD 9.8), mean BMI 28.7 (SD 4.2)), underwent TAA by one surgeon. Preoperative and postoperative radiographs, Ankle Osteoarthritis Scale (AOS) pain and disability and 36-item Short Form Health Survey (SF-36) version 2 scores were collected prospectively. Ancillary procedures, secondary procedures, and complications were recorded. Results. At mean 5.1 years follow-up (SD 2.6) (valgus) and 6.6 years (SD 3.3) (controls), mean AOS scores decreased and SF-36 scores increased significantly in both groups. Improvements in scores were similar for both groups – AOS pain: valgus, mean 26.2 points (SD 24.2), controls, mean 22.3 points (SD 26.4); AOS disability: valgus, mean 41.2 points (SD 25.6); controls, mean 34.6 points (SD 24.3); and SF-36 PCS: valgus, mean 9.1 points (SD 14.1), controls, mean 7.4 points (SD 9.8). Valgus ankles underwent more ancillary procedures during TAA (40 (80%) vs 13 (26%)) and more secondary procedures postoperatively (18 (36%) vs 7 (14%)) than controls. Tibiotalar deformity improved significantly (p < 0.001) towards a normal weightbearing axis in valgus ankles. Three valgus and four control ankles required subsequent fusion, including two for deep infections (one in each group). Conclusion. Satisfactory mid-term results were achieved in patients with preoperative valgus malalignment ≥ 15°, but they required more adjunctive procedures during and after TAA. Valgus coronal-plane deformity ≥ 15° is not an absolute contraindication for TAA if associated deformities are addressed. Cite this article: Bone Joint J 2020;102-B(12):1689–1696


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 47 - 51
1 Jul 2020
Kazarian GS Schloemann DT Barrack TN Lawrie CM Barrack RL

Aims. The aims of this study were to determine the change in the sagittal alignment of the pelvis and the associated impact on acetabular component position at one-year follow-up after total hip arthroplasty (THA). Methods. This study represents the one-year follow-up of a previous short-term study at our institution. Using the patient population from our prior study, the radiological pelvic ratio was assessed in 91 patients undergoing THA, of whom 50 were available for follow-up of at least one year (median 1.5; interquartile range (IQR) 1.1 to 2.0). Anteroposterior radiographs of the pelvis were obtained in the standing position preoperatively and at one year postoperatively. Pelvic ratio was defined as the ratio between the vertical distance from the inferior sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior SI joints. Apparent acetabular component position changes were determined from the change in pelvic ratio. A change of at least 5° was considered clinically meaningful. Results. Pelvic ratio decreased (posterior tilt) in 54.0% (27) of cases, did not change significantly in 34.0% (17) of cases, and increased (anterior tilt) in 12.0% (6) of cases when comparing preoperative to one-year postoperative radiographs. This would correspond with 5° to 10° of abduction error in 22.0% of cases and > 10° of error in 6.0%. Likewise, this would correspond with 5° to 10° of version error in 22.0% of cases and > 10° of error in 44.0%. Conclusion. Pelvic sagittal alignment is dynamic and variable after THA, and these changes persist to the one-year postoperative period, altering the orientation of the acetabular component. Surgeons who individualize the acetabular component placement based on preoperative functional radiographs should consider that the rotation of the pelvis (and thus the component version and inclination) changes one year postoperatively. Cite this article: Bone Joint J 2020;102-B(7 Supple B):47–51


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 20 - 26
1 Jul 2020
Romero J Wach A Silberberg S Chiu Y Westrich G Wright TM Padgett DE

Aims. This combined clinical and in vitro study aimed to determine the incidence of liner malseating in modular dual mobility (MDM) constructs in primary total hip arthroplasties (THAs) from a large volume arthroplasty centre, and determine whether malseating increases the potential for fretting and corrosion at the modular metal interface in malseated MDM constructs using a simulated corrosion chamber. Methods. For the clinical arm of the study, observers independently reviewed postoperative radiographs of 551 primary THAs using MDM constructs from a single manufacturer over a three-year period, to identify the incidence of MDM liner-shell malseating. Multivariable logistic regression analysis was performed to identify risk factors including age, sex, body mass index (BMI), cup design, cup size, and the MDM case volume of the surgeon. For the in vitro arm, six pristine MDM implants with cobalt-chrome liners were tested in a simulated corrosion chamber. Three were well-seated and three were malseated with 6° of canting. The liner-shell couples underwent cyclic loading of increasing magnitudes. Fretting current was measured throughout testing and the onset of fretting load was determined by analyzing the increase in average current. Results. The radiological review identified that 32 of 551 MDM liners (5.8%) were malseated. Malseating was noted in all of the three different cup designs. The incidence of malseating was significantly higher in low-volume MDM surgeons than high-volume MDM surgeons (p < 0.001). Pristine well-seated liners showed significantly lower fretting current values at all peak loads greater than 800 N (p < 0.044). Malseated liner-shell couples had lower fretting onset loads at 2,400 N. Conclusion. MDM malseating remains an issue that can occur in at least one in 20 patients at a high-volume arthroplasty centre. The onset of fretting and increased fretting current throughout loading cycles suggests susceptibility to corrosion when this occurs. These results support the hypothesis that malseated liners may be at risk for fretting corrosion. Clinicians should be aware of this phenomenon. Cite this article: Bone Joint J 2020;102-B(7 Supple B):20–26


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 42 - 42
1 Oct 2018
Schloemann DT Edelstein AI Barrack RL
Full Access

Introduction. Malposition of the acetabular component in total hip arthroplasty (THA) is linked to multiple adverse outcomes. Changes in the sagittal plane position of the pelvis, owing both to patient positioning in the operating room and to altered spinopelvic alignment following surgery, potentially contribute to variation in component position. The dynamics of sagittal plane pelvic position before, during, and after THA have not been defined. We measured the differences in pelvic ratio, a measure of sagittal plane pelvic position, between preoperative, intraoperative, and postoperative anteroposterior (AP) radiographs of patients undergoing THA in the lateral decubitus position. Methods. We retrospectively compared the radiographic pelvic ratio among 90 patients undergoing THA. AP radiographs were obtained in the standing position preoperatively and at 6 weeks after surgery; in the lateral decubitus position after trial reduction intraoperatively; and in the supine position in the post anesthesia care unit (PACU). Pelvic ratio was defined as the ratio between the vertical distance from the inferior sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior SI joints. Radlink software was used to determine the pelvic ratio on each radiograph. Changes in apparent cup position based on changes in pelvic ratio were calculated using data from the literature, and a change of at least 10 degrees in acetabular component position was defined as clinically meaningful. Analyses were performed using paired t-tests, with p<0.05 defined as significant. Results. 54% of patients had a change in pelvic ratio large enough to alter the apparent acetabular component anteversion by 10 degrees (49% increased and 6% decreased), and 12% had a change large enough to alter the apparent acetabular component inclination by 10 degrees (12% increased and 0% decreased) when the intraoperative AP radiograph was compared to the preoperative AP radiograph. 36% of patients had a change in pelvic ratio from the preoperative radiograph to the 6 week preoperative radiograph large enough to alter the apparent acetabular component anteversion by 10 degrees (5% increased and 31% decreased), and 8% had a change large enough to alter the apparent acetabular component inclination by 10 degrees (6% increased and 1% decreased). Discussion. Changes in the sagittal plane pelvic position between preoperative, intraoperative, and postoperative radiographs occur in a substantial number of patients. These changes correspond to altered functional position of the acetabular component in over half of patients on the intraoperative radiograph and over one third of patients on postoperative radiographs. This variability suggests that intraoperative imaging may be useful for avoiding outliers of component position, and calls into question the feasibility of achieving targeted component positions based on preoperative imaging alone


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 167 - 167
1 Mar 2008
Hotta H Yabuki Y Sasaki T Yamaguchi K Yanagimoto S
Full Access

Since the autumn of 2003, a computer-assisted system (VectorVision® Hip, version 2.1, Brain LAB, Germany) has been used to perform total hip arthroplasty (THA) operations in our hospital. In the present study, the postoperative acetabular cup position was evaluated using the records of the system and the data measured from postoperative radiographs. To date, 18 patients have been treated using this-system. We studied the cup inclination and anteversion records in this system recorded in the THA procedures. We also measured the cup inclination and anteversion using postoperative radiographs, according to the method described by Pradhan. The inclination and ante-version were the ‘operative’angles for this system and were the ‘radio graphical’ ones for measuring from the radiographs according to the definition described by Murray. The initial planning of the acetabular cup position was 45° ‘operative’ inclination and 20° ‘operative’ ante-version. From the system records, the average ‘operative’ inclination was 46.5°± 3.9° and the average ‘operative’ anteversion was 25.5°± 6.0°. The average ‘radio graphical’ inclination measured from the postoperative radiographs was 49.0°± 6.0°, and the average ‘radio graphical’ anteversion was 10.6°± 5.8°. Between the ‘operative’ angles from this system and the ‘radio graphical’ angles from the postoperative radiographs, the inclination was approximately the same, while the anteversion was different. When the ‘radio graphical’ anteversion was corrected for X-ray beam spreading and then converted to the ‘operative’ anteversion, the resulting ‘operative’ anteversion was 21.1°± 7.8°. And when the ‘operative’ anteversion recorded by this system was corrected for the pelvic tilt, the corrected ‘operative’ anteversion was 22.1°± 6.5°. The average difference between these corrected ‘operative’ anteversion in each case was 5.8°± 3.8°. Especially in 10 of the 18 cases, each difference was within 5°. The accuracy of the cup position using this computer-assisted system was shown by this study


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 58 - 58
1 Mar 2021
Kinghorn A Bowd J Whatling G Wilson C Mason D Holt C
Full Access

Abstract. OBJECTIVES. Valgus high tibial osteotomy (HTO) represents an effective treatment for patients with medial compartment osteoarthritis (OA) in a varus knee. However, the mechanisms which cause this clinical improvement are unclear. Previous studies suggest a wider stance gait can reduce medial compartment loading via reduction in the external knee adduction moment (KAM); a measure implicated in progression of medial compartment OA. This study aimed to measure whether valgus HTO is associated with a postoperative increase in static stance width. METHODS. 32 patients, recruited in the Biomechanics and Bioengineering Centre Versus Arthritis HTO study, underwent valgus (medial opening wedge) HTO. Weightbearing pre- and post- operative radiographs were taken showing both lower limbs. The horizontal distance, measured from a fixed point on the right talus to the corresponding point on the left, was divided by the talus width to give a standardised “stance width” for each radiograph. The difference between pre- and post- operative stance width was compared for each patient using a paired sample t-test. RESULTS. Preoperatively, mean stance was 4.00 talar-widths but postoperatively this increased to 5.41. This mean increase of 1.42 talar-widths was statistically significant (p=0.001) and represents a mean proportional increase in stance width of 35.5% following HTO. Of the 32 patients, 23 showed increased stance width and 9 decreased (range −4.64 to 6.00 talar-widths). CONCLUSIONS. These findings indicate an association of frontal plane surgical realignment at the proximal tibia via a medial opening wedge HTO with an increased stance width on postoperative radiographs. Considering both wider stance gait and HTO have been shown to affect the progression of medial compartment OA, these results may explain one mechanism contributing to the efficacy of HTO surgery. However, the range of changes in stance width suggests significant variability in how patients adapt at a whole-limb and whole-body level following HTO. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1062 - 1071
1 Aug 2020
Cheung JPY Fong HK Cheung PWH

Aims. To determine the effectiveness of prone traction radiographs in predicting postoperative slip distance, slip angle, changes in disc height, and lordosis after surgery for degenerative spondylolisthesis of the lumbar spine. Methods. A total of 63 consecutive patients with a degenerative spondylolisthesis and preoperative prone traction radiographs obtained since 2010 were studied. Slip distance, slip angle, disc height, segmental lordosis, and global lordosis (L1 to S1) were measured on preoperative lateral standing radiographs, flexion-extension lateral radiographs, prone traction lateral radiographs, and postoperative lateral standing radiographs. Patients were divided into two groups: posterolateral fusion or posterolateral fusion with interbody fusion. Results. The mean changes in segmental lordosis and global lordosis were 7.1° (SD 6.7°) and 2.9° (SD 9.9°) respectively for the interbody fusion group, and 0.8° (SD 5.1°) and -0.4° (SD 10.1°) respectively for the posterolateral fusion-only group. Segmental lordosis (ρ = 0.794, p < 0.001) corrected by interbody fusion correlated best with prone traction radiographs. Global lumbar lordosis (ρ = 0.788, p < 0.001) correlated best with the interbody fusion group and preoperative lateral standing radiographs. The least difference in slip distance (-0.3 mm (SD 1.7 mm), p < 0.001), slip angle (0.9° (SD 5.2°), p < 0.001), and disc height (0.02 mm (SD 2.4 mm), p < 0.001) was seen between prone traction and postoperative radiographs. Regression analyses suggested that prone traction parameters best predicted correction of slip distance (Corrected Akaike’s Information Criterion (AICc) = 37.336) and disc height (AICc = 58.096), while correction of slip angle (AICc = 26.453) was best predicted by extension radiographs. Receiver operating characteristic (ROC) cut-off showed, with 68.3% sensitivity and 64.5% specificity, that to achieve a 3.0° increase in segmental lordotic angle, patients with a prone traction disc height of 8.5 mm needed an interbody fusion. Conclusion. Prone traction radiographs best predict the slip distance and disc height correction achieved by interbody fusion for lumbar degenerative spondylolisthesis. To achieve this maximum correction, interbody fusion should be undertaken if a disc height of more than 8.5 mm is attained on preoperative prone traction radiographs. Level of Evidence: Level II Prognostic Study. Cite this article: Bone Joint J 2020;102-B(8):1062–1071


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 106 - 106
1 Feb 2017
Le D Smith K Mitchell R
Full Access

Introduction. Orientation of the acetabular component in total hip arthroplasty has been shown to influence component wear, stability, and impingement. Freehand placement of the component can lead to widely variable radiographic outcomes. Accurate abduction, in particular, can be difficult in the lateral decubitus position due to limited ability to appreciate and control positional obliquity of the pelvis. A CT-based mechanical navigation device has been shown to decrease cup placement error. This is an independent report of a single-surgeon's radiographic results using the device to control cup abduction. Patients and Methods. Sixty-four (64) consecutive elective THRs in 58 patients were performed via a supercapsular percutaneously-assisted (SuperPATH) surgical approach. Intraoperatively, the acetabular components were aligned with the aid of the CT-based mechanical navigation device (HipXpert; Surgical Planning Associates, Medford, MA). The cup orientation was then further adjusted to ensure that the anterior rim of the acetabular component was not prominent to avoid psoas impingement. Postoperatively, radiographic abduction was measured on standing postoperative radiographs. Results. Measured on standing postoperative radiographs, the cup radiographic abduction angle averaged 42.7° with a standard deviation of ± 3.9° and a range of 35° to 51°. Conclusions. Total hip arthroplasty using a CT-based navigation device as a guide for abduction led to cup implantation within a very narrow abduction range. This navigation device deserves more widespread interest and study, as acetabular component malposition remains a major concern in THR


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 60 - 60
23 Jun 2023
Yasunaga Y Ohshima S Shoji T Adachi N
Full Access

Satisfactory intermediate and long-term results of rotational acetabular osteotomy (RAO) for the treatment of early osteoarthritis secondary to developmental dysplasia of the hip have been reported. The purpose of this study is to examine the 30-year results of RAO. Between 1987 and 1994, we treated 49 patients (55 hips) with RAO for diagnosis of pre- OA or early-stage OA. Of those patients, 35 patients (43 hips) were available at a minimum of 28 years. The follow-up rate was 78.2% and the mean follow-up was 30.5 years. The mean age at the time of surgery was 34 years. Clinical evaluation was performed with the Merle d'Aubigne and Postel rating scale, and radiographic analyses included measurements of the center-edge angle, acetabular roof angle, and head lateralization index on preoperative, postoperative AP radiographs of the pelvis. Postoperative joint congruency was classified into four grades. The radiographic evidence of progression of OA was defined as the minimum joint space less than 2.5mm. The mean preoperative clinical score was 14.0, which improved to a mean of 15.3 at the time of the latest follow-up. The mean center-edge angle improved from 0.6° preoperatively to 34° postoperatively, the mean acetabular roof angle improved from 28.4°preoperatively to 1.0°postoperatively, the mean head lateralization index improved from 0.642 preoperatively to 0.59 postoperatively. Postoperative joint congruency was excellent in 11 hips, good in 29 hips, and fair in 3 hips. Nineteen patients (20 hips) had radiographic OA progression, and 10 patients (11 hips) were converted to THA. Kaplan-Meier survivorship analysis, with radiographic OA progression as the end point, predicted survival of 75.6% at 20 years and 48.8% at 30 years, and with THA conversion as the end point, 90.2% at 20 years and 71.2% at 30 years. The RAO is an effective surgical procedure for symptomatic dysplastic hips of pre- and early-stage OA and could change the natural history of the dysplastic hip


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 45 - 50
1 Jun 2019
Schloemann DT Edelstein AI Barrack RL

Aims. The aims of this study were to determine the change in pelvic sagittal alignment before, during, and after total hip arthroplasty (THA) undertaken with the patient in the lateral decubitus position, and to determine the impact of these changes on acetabular component position. Patients and Methods. We retrospectively compared the radiological pelvic ratio among 91 patients undergoing THA. In total, 41 patients (46%) were female. The mean age was 61.6 years (. sd. 10.7) and the mean body mass index (BMI) was 20.0 kg/m. 2. (. sd. 5.5). Anteroposterior radiographs were obtained: in the standing position preoperatively and at six weeks postoperatively; in the lateral decubitus position after trial reduction intraoperatively; and in the supine position in the post-anaesthesia care unit. Pelvic ratio was defined as the ratio between the vertical distance from the inferior aspect of the sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior aspect of the SI joints. Changes in the apparent component position based on changes in pelvic ratio were determined, with a change of > 5° considered clinically significant. Analyses were performed using Wilcoxon’s signed-rank test, with p < 0.05 considered significant. Results. Intraoperatively, in the lateral decubitus position, the pelvic ratio increased (anterior tilt) in 69.4% of cases, did not change significantly in 20.4%, and decreased (posterior tilt) in 10.2% of cases. When six-week postoperative radiographs were compared with preoperative radiographs, the pelvic ratio decreased in 44.9% of cases, did not change significantly in 42.3%, and increased in 12.8% of cases. This change in alignment correlated with a change in acetabular component version of > 5° in 79.6% of cases intraoperatively and 57.7% of cases at six weeks postoperatively. Conclusion. Changes in pelvic sagittal pelvic position occur throughout THA that, if unaccounted for, introduce errors in acetabular component placement. The use of intraoperative imaging may help the appropriate placement of the acetabular component. Cite this article: Bone Joint J 2019;101-B(6 Supple B):45–50


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 56 - 56
1 Jan 2018
Macheras G Lepetsos P Anastasopoulos P Tzefronis D Galanakos S Poultsides L
Full Access

Porous tantalum is a highly osteoinductive biomaterial, initially introduced in orthopedics in 1997, with a subsequent rapid evolution of orthopedic applications. The use of porous tantalum for the acetabular component in primary total hip arthroplasty (THA) has demonstrated excellent short-term and mid-term results. However, long term data are scarce. The purpose of this prospective study is to report the long-term clinical and radiological outcome following use of an uncemented porous tantalum acetabular component in primary THA with a minimum follow-up of 17.5 years, in a previously studied cohort of patients. We prospectively followed 128 consecutive primary THAs in 140 patients, between November 1997 and June 1999. A press-fit porous tantalum monoblock acetabular component was used in all cases. The presence of initial gaps in the polar region, as sign of incomplete seating of the monoblock cup, was assessed on the immediate postoperative radiographs. All patients were followed clinically and radiographically at 6, 12, and 24 weeks and 12 months and then at 2, 5, 8, 10, and 19 years, for a mean of 18.1 years (range 17.5 – 19 years). Periacetabular dome gap filling, acetabular cup migration and polyethylene wear were assessed by the EBRA digital measurement system, until 2 years postoperatively. Mean age of patients at the time of operation was 60.4 years old (range 24 – 72). Harris hip score, Oxford Hip Score and range of motion (ROM) were dramatically improved in all cases (p < 0.001). In the initial postoperative radiographs, periacetabular dome gaps were observed in the 15% of cases, and were progressively filled within 6 months. In 2 years postoperatively, the mean component migration, as shown in EBRA study, was 0.67 mm. At last follow-up, all cups were radiographically stable with no evidence of migration, gross polyethylene wear, progressive radiolucencies, osteolytic lesions or acetabular fractures. The survivorship with re-operation for any reason as end point was 92.8%, whereas the survivorship for aseptic loosening as an end point was 100%. Upon visual inspection, two removed acetabular components due to recurrent dislocation and infection, respectively, showed extensive bone osseointegration. In our primary THA series, the porous tantalum monoblock cup demonstrated excellent clinical and radiographic outcomes with no failures because of aseptic loosening at a mean follow-up of 18.1 years. Porous tantalum acetabular components showed excellent initial stability, produced less wear debris and revealed a great potential for bone ingrowth. Due to its unique osteoinductive properties and elliptical shape, porous tantalum monoblock cups have demonstrated superior short and long-term survivorship compared to other press fit prostheses in the market


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1654 - 1661
1 Dec 2020
Perelgut ME Polus JS Lanting BA Teeter MG

Aims. The direct anterior (DA) approach has been associated with rapid patient recovery after total hip arthroplasty (THA) but may be associated with more frequent femoral complications including implant loosening. The objective of this study was to determine whether the addition of a collar to the femoral stem affects implant migration, patient activity, and patient function following primary THA using the DA approach. Methods. Patients were randomized to either a collared (n = 23) or collarless (n = 26) cementless femoral stem implanted using the DA approach. Canal fill ratio (CFR) was measured on the first postoperative radiographs. Patients underwent a supine radiostereometric analysis (RSA) exam postoperatively on the day of surgery and at two, four, six, 12, 26, and 52 weeks postoperatively. Patient-reported outcome measures (Western Ontario and McMaster Universities Osteoarthritis (WOMAC) Index, the 12-item Short Form Health Survey Mental and Physical Score, and University of California, Los Angeles (UCLA) Activity Score) were measured preoperatively and at each post-surgery clinic visit. Activity and function were also measured as the weekly average step count recorded by an activity tracker, and an instrumented timed up-and-go (TUG) test in clinic, respectively. Results. Comparing the RSA between the day of surgery baseline exam to two weeks postoperatively, subsidence was significantly lower (mean difference 2.23 mm (SD 0.71), p = 0.023) with collared stems, though these patients had a greater CFR (p = 0.048). There was no difference (p = 0.426) in subsidence between stems from a two-week baseline through to one year postoperatively. There were no clinically relevant differences in PROMs; and there was no difference in the change in activity (p = 0.078) or the change in functional capacity (p = 0.664) between the collared stem group and the collarless stem group at any timepoint. Conclusion. Presence of a collar on the femoral stem resulted in reduced subsidence during the first two postoperative weeks following primary THA using the DA approach. However, the clinical implications are unclear, and larger studies examining patient activity and outcomes are required. Cite this article: Bone Joint J 2020;102-B(12):1654–1661


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1242 - 1247
3 Sep 2020
Hsu P Wu K Lee C Lin S Kuo KN Wang T

Aims. Guided growth has been used to treat coxa valga for cerebral palsy (CP) children. However, there has been no study on the optimal position of screw application. In this paper we have investigated the influence of screw position on the outcomes of guided growth. Methods. We retrospectively analyzed 61 hips in 32 CP children who underwent proximal femoral hemi epiphysiodesis between July 2012 and September 2017. The hips were divided into two groups according to the transphyseal position of the screw in the coronal plane: across medial quarter (Group 1) or middle quarter (Group 2) of the medial half of the physis. We compared pre- and postoperative radiographs in head-shaft angle (HSA), Reimer’s migration percentage (MP), acetabular index (AI), and femoral anteversion angle (FAVA), as well as incidences of the physis growing-off the screw within two years. Linear and Cox regression analysis were conducted to identify factors related to HSA correction and risk of the physis growing-off the screw. Results. A total of 37 hips in Group 1 and 24 hips in Group 2 were compared. Group 1 showed a more substantial decrease in the HSA (p = 0.003) and the MP (p = 0.032). Both groups had significant and similar improvements in the AI (p = 0.809) and the FAVA (p = 0.304). Group 1 presented a higher incidence of the physis growing-off the screw (p = 0.038). Results of the regression analysis indicated that the eccentricity of screw position correlated with HSA correction and increases the risk of the physis growing-off the screw. Conclusion. Guided growth is effective in improving coxa valga and excessive femoral anteversion in CP children. For younger children, despite compromised efficacy of varus correction, we recommend a more centered screw position, at least across the middle quarter of the medial physis, to avoid early revision. Cite this article: Bone Joint J 2020;102-B(9):1242–1247


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 380 - 380
1 Jul 2011
Gordon R Kejriwal R
Full Access

Digital radiographs have taken over from conventional radiographs in most of the hospitals in New Zealand. This has created a challenge with respect to templating and pre-operative planning of total hip replacement surgeries. Digital templating has not, until recently, been available in our hospitals. Recently, a digital templating system (Cedara) has become available and has been installed and used at Middlemore Hospital and at Manukau Surgical Centre. This system allows computerised templating of digital radiographs. The aim of this study was to assess the accuracy of digital templating and to compare this method to the “compromised” conventional templating that has been performed at Middlemore hospital for the last 10 years. In order to correct for magnification a fiducial stand has been created. This is a plastic stand and a pole with a movable 36mm metal ball. The ball is placed at the level of the greater trochanter and the stand is then placed between the patients legs. A standard templating “AP pelvis for hips” radiograph is then taken with the limbs internally rotated, such that the patellae are facing anteriorly. A traditional hard film was then created from this image for traditional acetate templating. Digital templating, with the Cedara system, was performed on the digital images after calibrating the image size using the fiducial image of known size. The results of the two methods were tabulated. The operation record was read and the component size and type was tabulated. The postoperative radiographs were assessed and the component positioning was evaluated and compared with the conventional and digital templates. A critical assessment of component size, with respect to under sizing and over sizing, was also performed on the postoperative radiographs and this was correlated with the digital and conventional templates. This templating, and the evaluation of the postoperative radiographs, was performed by the authors of this paper (a consultant surgeon and a registrar). The accuracy of the two templating methods was assessed by comparison with the post operative radiographs and also with the aid of the knowledge of the actual components which were used at the time of surgery. The templating images and radiographs of 100 patients were evaluated in the above stated manner and the results were analysed. The results from this analysis will be presented


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 19 - 19
1 Aug 2020
Morash K Gauthier L Orlik B El-Hawary R Logan K
Full Access

Slipped capital femoral epiphysis (SCFE) is traditionally treated with in situ fixation using a threaded screw, leading to physeal arrest while stabilizing the femoral head. Recently, there has been interest in alternative methods of fixation for SCFE, aiming to allow growth and remodelling of the femoral neck postoperatively. One such option is the Free Gliding SCFE Screw (Pega Medical), which employs a telescopic design intended to avoid physeal compression. The objective of this study is to evaluate radiographic changes of the proximal femur following in situ fixation using the Free Gliding SCFE Screw. This study retrospectively evaluated 28 hips in 14 consecutive patients who underwent in situ hip fixation using the Free Gliding SCFE Screw between 2014 and 2018. Initial postoperative radiographs were compared to last available follow-up imaging. Radiographic assessment included screw length, articulotrochanteric distance (ATD), posterior sloping angle (PSA), alpha angle, head-neck offset (HNO) and head-shaft angle (HSA). Of the 28 hips reviewed, 17 were treated for SCFE and an additional 11 treated prophylactically. Average age at surgery was 11.7 years, with an average follow-up of 1.44 years. Screw length increased by 2.3 mm (p < 0.001). ATD decreased from 25.4 to 22.2 mm (p < 0.001). Alpha angle decreased from 68.7 to 59.8 degrees (p = 0.004). There was a trend towards an increase in HNO (p = 0.07). There was no significant change in PSA or HAS. There were three complications (two patients with retained broken guide wires, and one patient requiring screw removal for hip pain). With use of the Free Gliding SCFE Screw, there was evidence of screw expansion and femoral neck remodelling with short-term follow-up. More research is required to determine the long-term impact of these changes on hip function, and to aid in patient selection for this technology


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 35 - 35
1 Dec 2022
Montanari S Griffoni C Cristofolini L Brodano GB
Full Access

Mechanical failure of spine posterior fixation in the lumbar region Is suspected to occur more frequently when the sagittal balance is not properly restored. While failures at the proximal extremity have been studied in the literature, the lumbar distal junctional pathology has received less attention. The aim of this work was to investigate if the spinopelvic parameters, which characterize the sagittal balance, could predict the mechanical failure of the posterior fixation in the distal lumbar region. All the spine surgeries performed in 2017-2019 at Rizzoli Institute were retrospectively analysed to extract all cases of lumbar distal junctional pathology. All the revision surgeries performed due to the pedicle screws pull-out, or the breakage of rods or screws, or the vertebral fracture, or the degenerative disc disease, in the distal extremity, were included in the junctional (JUNCT) group. A total of 83 cases were identified as JUNCT group. All the 241 fixation surgeries which to date have not failed were included in the control (CONTROL) group. Clinical data were extracted from both groups, and the main spinopelvic parameters were assessed from sagittal standing preoperative (pre-op) and postoperative (post-op) radiographs with the software Surgimap (Nemaris). In particular, pelvic incidence (PI), sagittal vertical axis (SVA), pelvic tilt (PT), T1 pelvic angle (TPA), sacral slope (SS) and lumbar lordosis (LL) have been measured. In JUNCT, the main failure cause was the screws pull-out (45%). Spine fixation with 7 or more levels were the most common in JUNCT (52%) in contrast to CONTROL (14%). In CONTROL, PT, TPA, SS and PI-LL were inside the recommended ranges of good sagittal balance. For these parameters, statistically significant differences were observed between pre-op and post-op (p<0.0001, p=0.01, p<0.0001, p=0.004, respectively, Wilcoxon test). In JUNCT, the spinopelvic parameters were out of the ranges of the good sagittal balance and the worsening of the balance was confirmed by the increase in PT, TPA, SVA, PI-LL and by the decrease of LL (p=0.002, p=0.003, p<0.0001, p=0.001, p=0.001, respectively, paired t-test) before the revision surgery. TPA (p=0.003, Kolmogorov-Smirnov test) and SS (p=0.03, unpaired t-test) differed significantly in pre-op between JUNCT and CONTROL. In post-op, PI-LL was significantly different between JUNCT and CONTROL (p=0.04, unpaired t-test). The regression model of PT vs PI was significantly different between JUNCT and CONTROL in pre-op (p=0.01, Z-test). These results showed that failure is most common in long fused segments, likely due to long lever arms leading to implant failure. If the sagittal balance is not properly restored, after the surgery the balance is expected to worsen, eventually leading to failure: this effect was confirmed by the worsening of all the spinopelvic parameters before the revision surgery in JUNCT. Conversely, a good sagittal balance seems to avoid a revision surgery, as it is visible is CONTROL. The mismatch PI-LL after the fixation seems to confirm a good sagittal balance and predict a good correction. The linear regression of PT vs PI suggests that the spine deformity and pelvic conformation could be a predictor for the failure after a fixation


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 3 - 3
1 Jul 2020
Chan G Aladwan R Hook S Rogers B Ricketts D Stott P
Full Access

Introduction. Dislocated hip hemiarthroplasties (HA) are associated with a 45% revision rate and 40% mortality rate. Implant selection for HA operations vary with no universally accepted implant choice. The WHiTE3 trial suggested older designs such as the Thompson has equitable outcomes to more modern and expensive implants such as the Exeter V40+Unitrax. Our multi-centre consecutive series of NOFs patients treated with HA assesses the impact of surgical and patient factors on dislocation risk. Methods. Medical and radiographic records for patients treated between 1. st. January 2009 and 30. th. September 2017 with a HA at three acute hospitals were reviewed. Implant and dislocation data were recorded. Patient demographics, comorbidities and operation details were extracted from the medical records and NHFD. Patients were excluded if there were no postoperative radiographs or when HA had been performed as a revision procedure. Results. We identified 4305 consecutive patients with 189 excluded. There was no difference in patient characteristics between the hospitals or implant types (p>0.05). Four HA implants were used during the study period; Thompson, Austin-Moore, Furlong and Exeter V40+Unitrax. 63 dislocations were identified (1.5%), median time to dislocation was 24 days. Dislocation rates for Thompson HAs were significantly higher (p=0.004) at 3.7%. No association was demonstrated with cemented versus uncemented, bipolar versus monopolar, fixed versus variable offsets, operating surgeon grade and dislocation rates (p>0.05). Patient factors (preoperative AMTS, postoperative AMTS, preoperative mobility and ASA grade) had no effect on dislocation (p>0.05). Discussion. Our study which is reflective current implant choices, demonstrates that Thompson implants for HA after NOFs have a significantly higher dislocation rates than other common prostheses, and their continued use should be reconsidered. This effect has not been demonstrated in previous studies. Patient, implant construct and surgeon factors had little bearing on the subsequent dislocation rate


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 213 - 213
1 Mar 2013
Kato M Shimizu T Yasura K Aoto T
Full Access

Background. We occasionally came across cortical atrophy of femurs with cemented collarless polished triple-taper stem in a short term period. This study aimed to estimate radiographs of cemented collarless polished triple-taper stem taken 6 months after the initial operation. Methods. Between May 2009 and April 2011, 97 consecutive patients underwent primary total hip arthroplasty and hemiarthroplasty using SC-stem or C-stem implants. At the 6 month follow-up, a radiographic examination was performed on 70 patients (71 hips). 44 hips had Total Hip Arthoplasty, 35 had osteoarthritis, 5 had idiopathic osteonecrosis, 2 had other diseases and 27 hips had hemiarthroplasty for femoral neck fractures. The postoperative radiographs were used to estimate the cementing grade. Then the 6 month postoperative radiographs were analyzed for changes in stem subsidence, cortical atrophy and cortical hypertrophy. According to the system of Gruen- cortical atrophy and cortical hypertrophy were classified on the femoral side. We defined no cortical atrophy as grade 0, cortical atrophy less than 1 mm as grade 1, more than 1 mm and less than 2 mm as grade 2, more than 2 mm as grade 3. Result. A cortical atrophy adjacent to the stem was found in zone II according to Gruen on grade 0 thirty-five radiographs (49%), grade 1 twenty (28%), grade 2 eleven (16%), grade 3 five (7%). in zone III grade 0 twenty-seven (38%), grade 1 thirty (42%), grade 2 ten (14%), grade 3 four (6%), in zone V grade 0 fifty (70%), grade 1 twenty (28%), grade 2 one (1%), grade 3 zero (0%), in zone VI grade 0 forty-nine (69%), grade 1 twenty (28%), grade 2 two (3%), grade 3 zero (0%). Cortical hypertrophy was only demonstrated in zone V in one case. In all cases the stem subsidence was less than 1 mm. Cortical atrophy including grade 1 was recognized in 38% of THA, and in 52% of femoral neck fractures. In one case the slight radiolucent line of the postoperative X-ray disappeared after 6 months. Discussion. Cortical atrophy was recognized more in the femoral neck fracture group than in the THA group. And Cortical atrophy was recognized in zone 2 and zone 3 more frequently than in zone 5 and zone 6. According to the finite element analysis of SC-stem more stress is received on the medial aspect of the stem during weight bearing, so it is suspected that more cortical atrophy on the lateral aspect is associated with stem design. This is compatible with the cortical hypertrophy reported with Exeter stem in zone 5. Conclusion. Cortical atrophy, including minor degree atrophy, occurred in 65% of cemented collarless polished triple-taper stem in short term periods after implantation. Cortical atrophy occurred in the lateral aspect of the stem more severely and more frequently than in the medial aspect. Cortical atrophy was also recognized in the femoral neck fracture group more more severely and more frequently than in the THA group


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 19 - 19
1 Apr 2019
Zhou Y Huang Y Tang H Guo S Yang D Zhou B
Full Access

Background. Failed ingrowth and subsequent separation of revision acetabular components from the inferior hemi-pelvis constitutes a primary mode of failure in revision total hip arthroplasty (THA). Few studies have highlighted other techniques than multiple screws and an ischial flange or hook of cages to reinforce the ischiopubic fixation of the acetabular components, nor did any authors report the use of porous metal augments in the ischium and/or pubis to reinforce ischiopubic fixation of the acetabular cup. The aims of this study were to introduce the concept of extended ischiopubic fixation into the ischium and/or pubis during revision total hip arthroplasty [Fig. 2], and to determine the early clinical outcomes and the radiographic outcomes of hips revised with inferior extended fixation. Methods. Patients who underwent revision THA utilizing the surgical technique of extended ischiopubic fixation with porous metal augments secured in the ischium and/or pubis in a single institution from 2014 to 2016 were reviewed. 16 patients were included based on the criteria of minimum 24 months clinical and radiographic follow-up. No patients were lost to follow-up. The median duration of follow-up for the overall population was 37.43 months. The patients' clinical results were assessed using the Harris Hip Score (HHS), Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index and Short form (SF)-12 score and satisfaction level based on a scale with five levels at each office visit. All inpatient and outpatient records were examined for complications, including infection, intraoperative fracture, dislocation, postoperative nerve palsy, hematoma, wound complication and/or any subsequent reoperation(s). The vertical and horizontal distances of the center of rotation to the anatomic femoral head and the inclination and anteversion angle of the cup were measured on the preoperative and postoperative radiographs. All the postoperative plain radiographs were reviewed to assess the stability of the components. Results. At the most recent follow-up, 11 (68.8%) patients rated their satisfaction level as “very satisfied” and 4 (25.0%) were “satisfied.” The median HHS improved significantly and the WOMAC global score decreased significantly at the latest follow-up (? 0.001). No intraoperative or postoperative complications were identified. All constructs were considered to have obtained bone ingrowth fixation. The median vertical distance between the latest postoperative center of rotation to the anatomic center of the femoral head improved from 14.7±10.05 mm preoperatively to 6.77±9.14 mm at final follow-up (p=0.002). The median horizontal distance between the latest postoperative center of rotation to the anatomic center of femoral head improved from 6.3±12.07 mm laterally preoperatively to 2.18±6.98 mm medially at the most recent follow-up (p=0.013) postoperatively. The median acetabular cup abduction angle improved from 55.04°±10.11° preoperatively to 44.43°± 5.73° at the most recent follow-up postoperatively (p=0.001). However, there was no difference in the median cup anteversion angles preoperatively (9.15°±5.36°) to postoperatively (9.66°±3.97°) (P=0.535). Conclusions. Early follow-up of patients reconstructed with the technique of extended ischiopubic fixation with porous metal augments demonstrated satisfactory clinical outcomes, restoration of the center of rotation and adequate biological fixation. For any figures or tables, please contact the authors directly