Postoperative length of stay (LOS) and discharge dispositions following arthroplasty can be used as surrogate measurements for improvements in patients’ pathways and costs. With the increasing use of robotic technology in arthroplasty, it is important to assess its impact on LOS. The aim of this study was to identify factors associated with decreased LOS following robotic arm-assisted total hip arthroplasty (RO THA) compared with the conventional technique (CO THA). This large-scale, single-institution study included 1,607 patients of any age who underwent 1,732 primary THAs for any indication between May 2019 and January 2023. The data which were collected included the demographics of the patients, LOS, type of anaesthetic, the need for treatment in a post-anaesthesia care unit (PACU), readmission within 30 days, and discharge disposition. Univariate and multivariate logistic regression models were used to identify factors and the characteristics of patients which were associated with delayed discharge.Aims
Methods
Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA. This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery.Aims
Methods
Introduction. Short-stem hip arthroplasty is gaining popularity as a method of treating hip arthritis in biologically younger patients. The potential benefit of using a short-stem is preservation of bone in the proximal femur for a future revision. We have compared the early clinical and radiological results of a short-stem hip arthroplasty versus a
To date, the literature has not yet revealed superiority of Minimally Invasive (MI) approaches over conventional techniques. We performed a systematic review to determine whether minimally invasive approaches are superior to conventional approaches in total hip arthroplasty for (1) clinical and (2) functional outcomes. We performed a meta-analysis of level 1 evidence to determine whether (3) minimally invasive approaches are superior to conventional approaches for clinical outcomes. All studies comparing MI approaches to conventional approaches were eligible for analysis. The PRISMA guidelines were adhered to throughout this study. Registries were searched using the following MeSH terms: ‘minimally invasive’, ‘muscle-sparing’, ‘THA’, ‘THR’, ‘hip arthroplasty’ and ‘hip replacement’. Locations searched included PubMed, the Cochrane Library, ClinicalTrials.gov, the EU clinical trials register and the International Clinical Trials Registry Platform (World Health Organisation). Twenty studies were identified. There were 1,282 MI THAs and 1,351 conventional THAs performed. There was no difference between MI and conventional approaches for all clinical outcomes of relevance including all-cause revision (p=0.959), aseptic revision (p=0.894), instability (p=0.894), infection (p=0.669) and periprosthetic fracture (p=0.940). There was also no difference in functional outcome at early or intermediate follow-up between the two groups (p=0.38). In level I studies exclusively, random-effects meta-analysis demonstrated no difference in the rate of aseptic revision (p=0.461) between both groups. Intermuscular MI approaches are equivalent to conventional THA approaches when considering all-cause revision, aseptic revision, infection, dislocation, fracture rates and functional outcomes. Meta-analysis of level 1 evidence supports this claim.
Purpose: Surface replacement arthroplasty is being increasingly offered as the treatment of choice to young and active patients with hip arthritis with proposed advantages including bone conservation and better functional outcome. Excellent outcome has been reported in the few recent short-term clinical series of surface replacement arthroplasty. However they have an inbuilt patient selection bias. There are no direct prospective randomized studies comparing the newer generation of surface replacement arthroplasty with
The incorporation of computer navigation in total hip arthroplasty (THA) has been much slower then for total knee arthroplasty (TKA). Computer navigation has proven itself in the realm of TKA but still has yet to advance in THA. The reasons for this include the lack of ease of incorporation, accuracy and precision, and the addition of overall operative time. Another reason for this lack of progress is that a majority of THA's are done with the patient in the lateral position through a posterior or lateral approach making the tracker placement and the registration process somewhat cumbersome. In the direct anterior approach the patient is in the supine position, which accommodates pelvic tracker placement and significantly facilitates the registration process. At our institution we use the direct anterior approach and computer navigation on all of our primary THA's. We hypothesized that computer navigation facilitates cup placement and leg length determination with out significantly increasing our operative time. This was a prospective study comparing a consecutive series of 150 computer navigated total hips to a consecutive series of 150 none navigated total hips. The two groups were similar by age, sex, and BMI. Operative times were collected using our secure online database. The start and stop of operative time was incision to final reduction respectively. Post operative radiographs were analyzed using TraumaCad 2.0 (Voyant Health, Columbia, MD). Cup angle and leg length were measured on A/P pelvic views. Simple descriptive statistics and t-tests were used to analyze data.Introduction
Materials and Methods
In this study we compare survivorship and patient reported outcome measures in robotically assisted versus
In-hospital length of stay (LOS) and discharge disposition following arthroplasty could act as surrogate measures for improvement in patient pathways, and have major cost saving implications for healthcare providers. With the ever-growing adoption of robotic technology in arthroplasty, we wished to evaluate its impact on LOS. The objectives of this study were to compare LOS and discharge disposition following robotic-arm assisted (RO THA) versus
There has been a renewed interest in surface replacement arthroplasty over the last decade, with the hope and expectation that this procedure would provide an advantage over
Introduction. Hip resurfacing arthroplasty (HRA) lost its popularity because of excessive wear of the ASR M/M design. Now that causes of wear have been identified, it remains an attractive treatment option for young patients because of its bone-conserving nature, the preservation of bone mineral density, a low dislocation rate, and its biomechanical precision. Methods. We assessed the long-term clinical outcomes of 1074 patients (1321 hips) who were implanted with hybrid Conserve. ®. Plus HRA, with 556 surgeries performed in patients younger than 50 years of age (average, 41.6 years) compared to 765 surgeries performed in patients 50 years or older (average, 58.1 years). 74% of the patients were male. There were no exclusion criteria. The <50 group had a larger proportion of dysplasia and hips operated during the first generation of surgical technique. Results. The mean elapse time after surgery was 15.6 years (range 7.4 to 22.5 years). We found no difference in UCLA pain, walking and function scores between the two groups except for a slightly higher activity level in the younger group (7.4 vs. 7.2, p=0.0172). Quality of life SF-12 scores were also comparable. Although we found better survivorship rates for the group of older patients (Log-rank test p=0.0107 – Figure 1) between the younger and older patients (Table 1), this difference was largely explained by the greater proportion of dysplasia (p=0.0001) and 1. st. generation hips (p=0.044) in the <50 group. The rate of post-operative complications (dislocations, sepsis, neve palsies, blood-related and others) was not significantly different between groups (p=0.3738). However, the complication rate dropped significantly (p=0.0390) in both groups from 6.4% for the first and 2. nd. generations of surgical technique (n=670) to 3.8% with the 3. rd. generation of surgical technique (n=651). Conclusions. The long-term results of metal-on-metal HRA meet and even surpass the original expectations in young and active adults, with survivorship rates far superior to those reported in registries for
We report a rare case of Hip Resurfacing dislocation three years after a bilateral Hip Resurfacing in a very strong patient and show the maneuver to do a closed reduction on a film done at the surgical theatre under general anesthesia. Hip resurfacing dislocation is a very rare entity described in the literature and more rare after three years. With
The purpose of this study is to assess the accuracy of component positioning and incidence of peri-operative and 90-day post-operative complications following robotic arm-assisted and
Resurfacing arthroplasty is advantageous over
The aim of this study was to investigate the potentially increased risk of dislocation in patients with neurological disease who sustain a femoral neck fracture, as it is unclear whether they should undergo total hip arthroplasty (THA) or hemiarthroplasty (HA). A secondary aim was to investgate whether dual-mobility components confer a reduced risk of dislocation in these patients. We undertook a longitudinal cohort study linking the Swedish Hip Arthroplasty Register with the National Patient Register, including patients with a neurological disease presenting with a femoral neck fracture and treated with HA, a conventional THA (cTHA) with femoral head size of ≤ 32 mm, or a dual-mobility component THA (DMC-THA) between 2005 and 2014. The dislocation rate at one- and three-year revision, reoperation, and mortality rates were recorded. Cox multivariate regression models were fitted to calculate adjusted hazard ratios (HRs).Aims
Methods
Metal-on-metal hip resurfacing (MoM-HR) has seen decreased usage due to safety and longevity concerns. Joint registries have highlighted the risks in females, smaller hips, and hip dysplasia. This study aimed to identify if reported risk factors are linked to revision in a long-term follow-up of MoM-HR performed by a non-designer surgeon. A retrospective review of consecutive MoM hip arthroplasties (MoM-HRAs) using Birmingham Hip Resurfacing was conducted. Data on procedure side, indication, implant sizes and orientation, highest blood cobalt and chromium ion concentrations, and all-cause revision were collected from local and UK National Joint Registry records.Aims
Methods
The Birmingham Hip Resurfacing (BHR) arthroplasty has been used as a surgical treatment of coxarthrosis since 1997. We present 20-year results of 234 consecutive BHRs performed in our unit. Between 1999 and 2001, there were 217 patients: 142 males (65.4%), mean age 52 years (18 to 68) who had 234 implants (17 bilateral). They had patient-reported outcome measures collected, imaging (radiograph and ultrasound), and serum metal ion assessment. Survivorship analysis was performed using Kaplan-Meier estimates. Revision for any cause was considered as an endpoint for the analysis.Aims
Methods
Hip resurfacing remains a potentially valuable surgical procedure for appropriately-selected patients with optimised implant choices. However, concern regarding high early failure rates continues to undermine confidence in use. A large contributor to failure is adverse local tissue reactions around metal-on-metal (MoM) bearing surfaces. Such phenomena have been well-explored around MoM total hip arthroplasties, but comparable data in equivalent hip resurfacing procedures is lacking. In order to define genetic predisposition, we performed a case-control study investigating the role of human leucocyte antigen (HLA) genotype in the development of pseudotumours around MoM hip resurfacings. A matched case-control study was performed using the prospectively-collected database at the host institution. In all, 16 MoM hip resurfacing 'cases' were identified as having symptomatic periprosthetic pseudotumours on preoperative metal artefact reduction sequence (MARS) MRI, and were subsequently histologically confirmed as high-grade aseptic lymphocyte-dominated vasculitis-associated lesions (ALVALs) at revision surgery. ‘Controls’ were matched by implant type in the absence of evidence of pseudotumour. Blood samples from all cases and controls were collected prospectively for high resolution genetic a nalysis targeting 11 separate HLA loci. Statistical significance was set at 0.10 a priori to determine the association between HLA genotype and pseudotumour formation, given the small sample size.Aims
Methods
Resurfacing total hip replacement using metal on metal bearings is increasing in popularity, but the outcomes are currently unclear. We report a series of 23 hips in 20 patients who underwent resurfacing total hip replacement over a period of 4 years. The mean age at surgery was 47 years (21–61). There were 8 females and 12 male patients. The mean follow up was 27 months (range 6 to 50 months). Before performing this study, our impression was that most outcomes were good but that there appeared to be more variability in pain relief than anticipated after
Objectives. The primary objective of this study was to compare accuracy in restoring the native centre of hip rotation in patients undergoing
Aims: To compare the results of resurfacing hip arthroplasty with
The Birmingham hip resurfacing metal-on-metal arthroplasty was introduced in 1997 and has shown promising short- to mid-term results. We used radiostereophotogrammetric analysis (RSA) to study the stability of 20 resurfacing arthroplasties over a follow-up period of 24 months. Radiological examinations for RSA were performed immediately after surgery and at two, six, 12 and 24 months after operation. Precision and detection of migration thresholds (non-zero movement) were calculated. All the results corresponded well to those found in similar experimental arrangements with standard hip prostheses. Migration of the cup and vertical and mediolateral migration of the head were calculated. The values were low at two years compared with those of earlier studies of cemented femoral components in
Systemic concentrations of metal ions (cobalt and chromium) are persistently elevated in patients with metal-on-metal hip resurfacing (MOMHR) compared to
A conceptually new, to the North American market, acetabular design is currently available when performing a total hip arthroplasty – the dual mobility socket. Essentially this is a press-fit acetabular component with a polished surface (either modular or monoblock) that articulates with a large polyethylene head with a 28 mm ball inserted into that polyethylene in a similar fashion to a bipolar design. Proponents of this design advocate its use to reduce the risk of dislocation, and it is being offered as an alternative to constrained liners and also as a potential prophylactic application in revision and high risk patients. The concerns regarding this construct include:. Wear - A large polyethylene head articulating against a polished metal surface may have much greater wear than a conventional metal against polyethylene bearing. Hip simulator data has shown this previously. Additionally there are two articulating surfaces, potentially leading to a greater combined wear than one would see with just a singular surface. Clinical data - At present there are predominately short term published reports on this implant, many from the same centers. There are no control groups with other implants in these same “at risk” patients. There is no registry data to date on this implant. Patient Population - A difficult question to answer is which patient is at risk for dislocation and if one was going to apply this new technology, which patient would receive it? In the original published series, 26% of patients undergoing THA had this implant. Does the increased risk of wear and osteolysis warrant the use of this implant in a primary setting?. Unique complication - A unique complication has been described labeled intra-prosthetic dislocation. This occurs when the inner femoral ball disassociates from the polyethylene. The incidence has been reported up to 2% in some series. This complication alone equals the current rate of hip instability in a Medicare database with a
Hip resurfacing offers an attractive alternative to
INTRODUCTION. THA as primary treatment for displaced femoral neck fractures in elderly still remains a prominent concern. Overall dislocation rate after total hip arthroplasty (THA) is reported form 1∼5%. But, it is quiet different in situation of femur neck fracture in elderly. The THA is associated with higher rates of dislocation (8%∼11%) in eldery compared to hemiarthroplasty even though THA showed better clinical and functional scores. Recently resurgence about THA using DMC comes after improvement of manufacturing technology. The aim of this prospective multicenter study is to assess the rates of dislocation and re-operation for displaced femoral neck fractures in elderly with THA with Dual Mobility Cup (DMC) and to review systematically comparison of previous reports. Up to our knowledge, this is first report from asian conutry about the clinical outcomes THA using DMC for displaced femur neck fracture in elderly. METHODS. Prospective consecutive groups of patients treated for displaced femoral neck fractures by three surgeons at each three center were included. 131 hips underwent THA with DMC for acute displaced femoral neck fracture in patients aged older than 70 years. Data regarding rates of dislocation and re-operation were obtained by review of medical records. Additionally From 2009 which the US FDA first approved the DMC, the authors searched reports regarding to THA using DMC for displaced femur neck fracture in elderly using the MEDLINE including cases series and comparative studies with bipolar hemiarthroplasty and THA. Therefore, current report was compared with previous reports. RESULTS. The reports about THA using DMC for displaced femur neck fracture in elderly were limited. Most of them comes from European countries. Comparative study with THA from Sweden reported the dislocation rate of THA using DMC with average aged 75-year is 0%. In Denmark study, the bipolar hemiarthroplasty showed 14% of dislocation rate for femur neck fracture in patient aged 75 years but, THA using DMC is 4.6%. Two cases series from French reported about 1–4% in patients aged 80 years. In our multicenter study, dislocation occurred in 6/131 hips (4.6%) treated with total hip arthroplasty using DMC for displaced femur neck fracture over 70 years older patients. Reoperations including periprosthetic fracture and fixation failure of cup were required in 1/43 (2.3%) hips treated with total hip arthroplasty using DM cup. These result is comparable to European reports. DISCUSSION AND CONCLUSION. Our findings indicate that THA with DMC can not guarantee to prevent the dislocation for high risk elderly patients, but the overall rate of dislocation can be comparable to those of bipolar hemiarthroplasty and reduced compared to
To establish the survivorship, function, and metal ion levels in an unselected series of metal-on-metal hip resurfacing arthroplasties (HRAs) performed by a non-designer surgeon. We reviewed 105 consecutive HRAs in 83 patients, performed by a single surgeon, at a mean follow-up of 14.9 years (9.3 to 19.1). The cohort included 45 male and 38 female patients, with a mean age of 49.5 years (SD 12.5)Aims
Methods
BACKGROUND. We originally performed metal-on-metal hip resurfacing using a Townley designed Vitallium Total Articular Replacement Arthroplasty (TARA) curved stemmed prosthesis. Neither the acetabular or femoral components were cemented or had porous coating. The bearing surfaces were consistently polar bearing. The surgical objectives were to preserve bone stock, maintain normal anatomy and mechanics of the hip joint and to approximate the normal stress transmission to the supporting femoral bone. The functional objectives were better sports participation, less thigh pain and limp, less perception of a leg length difference and a greater perception of a normal hip. Metal-on-metal was selected to conserve acetabular bone and avoid polyethylene associated osteolysis. Relatively few cases were performed until the Conserve Plus and later the Birmingham Hip Resurfacing systems became available. METHODS. We examined the results of metal-on-metal hip resurfacing in patient with at least 10 years of follow-up and an age less than 50 at the time of surgery. We did not have access to the Birmingham Prosthesis until 2006. We performed 101 TARA procedures and 397 Conserve Plus procedures for 357 patients. For the combined series the mean age was 43 and 62% of patients were male. 34 patients had a
Peri-articular soft-tissue masses or ‘pseudotumours’
can occur after large-diameter metal-on-metal (MoM) resurfacing
of the hip and
Metal-metal hip resurfacing offers the advantage of conservation of femoral bone stock. In addition, the implant may offer enhanced resistance to dislocation in comparison with
Introduction. Bearing surfaces used for total hip arthroplasty must have characteristics including bio-compatibility, low friction and low wear rate. Bearing combinations are generally characterised as Soft on Hard/Hard. In general, all newer bearing combinations have reduced wear but may present with other issues that impact on patient outcomes. Materials. The Australian Orthopaedic Association – National Joint Replacement Registry classifies bearing surfaces into six categories. These are metal on polyethylene, ceramic on polyethylene, metal on metal, ceramic on ceramic, ceramic on metal and a sixth category relating to a small number of procedures where the bearing surface is yet to be classified. 147,422
A 34-year-old woman with a benign form of osteopetrosis developed osteoarthritis of the hip. In order to avoid the difficulties associated with inserting the femoral component of a
Background. Hip resurfacing has resurged in the last decade due to a renewed interest in metal on metal bearing. One of the proposed advantages is ease of revision of the femoral component. Short term functional results after femoral revision are similar to those after
Introduction: Peri-prosthetic fractures following hip resurfacing arthroplasty are difficult fractures to treat. The surgeon is faced with the task of either attempting to fix the fracture if feasible or revise the resurfacing implant to a
Aim: Component positioning may be adversely affected by minimally invasive approach in total hip replacement due to restricted visualization. Problems with proper alignement are suggested to concern anteversion more than inclination and occur particulary in the lateral position. Method: 53 patients were enrolled prospectively randomised to each group. First group (standard group, n= 30pts) underwent
Metal on metal hip resurfacing was introduced in 1992 by Derek McMinn initially using an all cementless device and then an all cemented device. A hybrid resurfacing with a cemented femoral component and a cementless acetabular component was introduced in 1994. The manufacturer of the hybrid hip resurfacing was changed in 1996. Since 1997 the Birmingham hip resurfacing has been in continuous use. The device is approved by NICE (National Institute for Clinical Excellence) for use within the NHS in patients with Osteoarthritis of the hip. The device is not yet approved for use in patients with Rheumatoid Arthritis and other types of inflammatory arthritis. There are concerns regarding bone quality in rheumatoid patients, which may result in a high incidence of component loosening or femoral neck fracture.
We have compared the biomechanical nature of the reconstruction of the hip in
Patients with Neuromuscular disorders who have an arthritic hip joint present unique challenges. Due to inadequate bone stock, bony deformity and muscle imbalance there is a potentially increased risk of dislocation. These patients who have undergone
Purpose. There are some concerns about doing hip resurfacing arthroplasty in ONFH due to bone defect which can cause mechanical weakness of femoral component and highly active young age of patients which can cause high wear rate and failure rate. The purpose of this study is to verify the HRA is safe procedure in ONFH in the aspect of mechanical and biological issue. Materials and Methods. Between December 1998 and May 2005, 185 hips of 169 patients underwent MoM HRA using Birmingham Hip Resurfacing System® at single center. 166 hips (26 hips of female, 140 hips of male) of 144 patients have been reviewed for at least 7 years after MoM HRA. Mean follow-up period was 101.8 (84–178) months. Their mean age at the time of operation was 37.7(16–67) years old. Clinically, Harris hip scores (HHS), UCLA activity scores and range of motion were evaluated. Radiologically, the extent of necrotic area in preoperative MRI and radiolucency around implants, narrowing of retained neck, impingement, stress shielding, and heterotopic ossification were evaluated in the serial anteroposterior and groin lateral radiographs of hip. Complications were defined as joint dislocation, infection, implant loosening, femoral neck fracture and pseudotumor. Failure was defined as revision arthroplasty due to the complications. Results. The extent of necrotic area in preoperative MRI was average 37.6 (13.3–65)%. Clinically, average HHS was improved from 81.7 points to 98.5 points at last follow-up. Average UCLA activity score at last follow-up was 9.0 points. Range of motion at last follow-up was very satisfactory. There was no patient with severe pain around hip joint. Radiologically, radiolucency was shown around acetabular component in 2 cases (1.2%) and around stem of femoral components in 3 cases (1.8%). Fracture of femoral neck was seen in 1 case(0.6%). Moderate narrowing changes of retained femoral neck were noticed in 4 cases (2.4%). Impingement was seen in 12 cases (7.2%). We found only 1 case of osteolysis at Gruen zone III of acetabulum. Heterotopic ossification was found in 5 cases (3.0%). There was no case with hip dislocation, infection or pseudotumor. Revision surgeries after the primary resurfacing arthroplasty were performed in 4 cases (2.4%). Three hips were revised to the
Introduction: The hip resurfacing in younger patients is being performed more frequently in the UK. At the same time
Introduction:
Background: Because of the changing demographics of the population and improvements in prosthesis design and surgical technique, ever-increasing numbers of younger patients are undergoing joint replacement. Younger patients often receive hip resurfacing rather than conventional THR because of the preservation of bone stock and the lower risk of dislocation. However, pain relief and restoration of function for younger patients is particularly important to continue with a normal, active life. Yet there is little existing research to establish if hip resurfacing results in better patient-reported outcomes than
Metal-on-Metal devices generate significantly lower volumetric wear than
Metal-on-metal hip resurfacing arthroplasty is a conservative procedure that is becoming an increasingly popular option for young arthritic patients most likely to undergo a secondary procedure in their lifetime. The stability of the acetabular component is of particular concern in these patients who show an increased risk of failure of the cemented acetabular cups in
Metal-on-metal bearings have become popular in the last ten years because of a low wear rate combined with the ability to use large head sizes for
There is an increased risk of dislocation of the hip after the resection of a periacetabular tumour and endoprosthetic reconstruction of the defect in the hemipelvis. The aim of this study was to determine the rate and timing of dislocation and to identify its risk factors. To determine the dislocation rate, we conducted a retrospective single-institution study of 441 patients with a periacetabular tumour who had undergone a standard modular hemipelvic endoprosthetic reconstruction between 2003 and 2019. After excluding ineligible patients, 420 patients were enrolled. Patient-specific, resection-specific, and reconstruction-specific variables were studied using univariate and multivariate analyses.Aims
Methods
Hip resurfacing has in recent years become increasingly popular as an arthroplasty technique, particularly amongst younger patients with more active lifestyles. The procedure has been heralded as a more conservative option, aimed at those wishing to continue strenuous work and recreational activities. In the populalapress and the internet, many claims are made regarding aspects of this procedure, but little evidence has appeared in the scientific literature, either with the results of resurfacing or comparing resurfacing to
Introduction: Minimally invasive total hip arthroplasty has evoked substantial controversy with regard to whether it provides superior outcomes compared with
Introduction: Resurfacing arthroplasty of the hip joint has advantages of minimal bone resection, restoration of normal anatomy, and biomechanical circumstances. This study was undertaken to analyze the clinical and radiographic results of the resurfacing arthroplasty in patients with osteonecrosis of the femoral head (ONFH). Materials and Methods: Between September 1998 and September 2001, 40 hips in 39 patients with ONFH had a resurfacing arthroplasty with the Birmingham Hip Resurfacing (BHR) system. The mean age at the time of operation was 38.3 years. The average follow-up period was 36.8 months after operation. The patients were clinically evaluated by hip pain, Harris hip scores, range of motion, and radiographically evaluated for wear, change of cup position, loosening, and osteolysis. Results: The preoperative Harris hip score averaged 70.4 points and the degrees of flexion and internal rotation were 94° and 8°, respectively. The average Harris hip score at the last follow-up was 95.4 points. The degrees of flexion and internal rotation at last follow-up were 120°, and 20°, respectively. No patient complained of limb length discrepancy or pain in the hip or thigh. Rehabilitation programs and return to normal activities were earlier than that of
Introduction: Metal-on-metal hip resurfacing arthroplasty is one option for young and active patients with advanced hip disease. Intraoperative or immediate postoperative femoral neck fractures complicating a metal-on-metal hip resurfacing is a well described complication as a result of neck notching and stress shielding of the femoral head. The literature contains very little evidences on the conservative mode of treatment for peri-prosthetic fractures following the index operation with a favourable and an unfavourable outcome. We report a case of femoral neck fracture incurred three months after metal-on-metal hip resurfacing resulting in a varus malunion. Case report: A 55 year old lady underwent metal-on-metal surface hip replacement for advanced osteoarthritis of the left hip. The implants used were Cormet 2000 uncemented 50mm dual coated cup and cemented 44mm femoral head. Intraoperative bone quality was good and no technical difficulties were encountered. She was admitted three months later with a painful left hip after sustaining a fall. The radiograph confirmed left periprosthetic femoral neck fracture with resurfacing prosthesis in situ. She was scheduled for elective revision surgery of the femoral component. The patient elected to go home with the intention of getting readmitted. Initially lost to follow-up, she self referred after 30 months of her fracture with shortening and persistent painful limp. The clinical examination revealed 1.5 cm of true limb shortening with restricted terminal range of abduction and rotational movements. The radiographs revealed a varus malunited fracture with proximal migration of greater trochanter. The acetabular component was well fixed in situ. She is awaiting revision surgery by conversion to