header advert
Results 1 - 50 of 7296
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 610 - 621
1 Jun 2023
Prodromidis AD Chloros GD Thivaios GC Sutton PM Pandit H Giannoudis PV Charalambous CP

Aims. Loosening of components after total knee arthroplasty (TKA) can be associated with the development of radiolucent lines (RLLs). The aim of this study was to assess the rate of formation of RLLs in the cemented original design of the ATTUNE TKA and their relationship to loosening. Methods. A systematic search was undertaken using the Cochrane methodology in three online databases: MEDLINE, Embase, and CINAHL. Studies were screened against predetermined criteria, and data were extracted. Available National Joint Registries in the Network of Orthopaedic Registries of Europe were also screened. A random effects model meta-analysis was undertaken. Results. Of 263 studies, 12 were included with a total of 3,861 TKAs. Meta-analysis of ten studies showed high rates of overall tibial or femoral RLLs for the cemented original design of the ATTUNE TKA. The overall rate was 21.4% (95% confidence interval (CI) 12.7% to 33.7%) for all types of design but was higher for certain subgroups: 27.4% (95% CI 13.4% to 47.9%) for the cruciate-retaining type, and 29.9% (95% CI 15.6% to 49.6%) for the fixed-bearing type. Meta-analysis of five studies comparing the ATTUNE TKA with other implants showed a significantly higher risk of overall tibial or femoral RLLs (odds ratio (OR) 2.841 (95% CI 1.219 to 6.623); p = 0.016) for the ATTUNE. The rates of loosening or revision for loosening were lower, at 1.2% and 0.9% respectively, but the rates varied from 0% to 16.3%. The registry data did not report specifically on the original ATTUNE TKA or on revision due to loosening, but ‘all-cause’ five-year revision rates for the cemented ATTUNE varied from 2.6% to 5.9%. Conclusion. The original cemented ATTUNE TKA has high rates of RLLs, but their clinical significance is uncertain given the overall low associated rates of loosening and revision. However, in view of the high rates of RLLs and the variation in the rates of loosening and revision between studies and registries, close surveillance of patients who have undergone TKA with the original ATTUNE system is recommended. Cite this article: Bone Joint J 2023;105-B(6):610–621


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 582 - 588
1 Jun 2024
Bertram W Howells N White SP Sanderson E Wylde V Lenguerrand E Gooberman-Hill R Bruce J

Aims. The aim of this study was to describe the prevalence and patterns of neuropathic pain over one year in a cohort of patients with chronic post-surgical pain at three months following total knee arthroplasty (TKA). Methods. Between 2016 and 2019, 363 patients with troublesome pain, defined as a score of ≤ 14 on the Oxford Knee Score pain subscale, three months after TKA from eight UK NHS hospitals, were recruited into the Support and Treatment After Replacement (STAR) clinical trial. Self-reported neuropathic pain and postoperative pain was assessed at three, nine, and 15 months after surgery using the painDETECT and Douleur Neuropathique 4 (DN4) questionnaires collected by postal survey. Results. Symptoms of neuropathic pain were common among patients reporting chronic pain at three months post-TKA, with half reporting neuropathic pain on painDETECT (191/363; 53%) and 74% (267/359) on DN4. Of those with neuropathic pain at three months, half continued to have symptoms over the next 12 months (148/262; 56%), one-quarter had improved (67/262; 26%), and for one-tenth their neuropathic symptoms fluctuated over time (24/262; 9%). However, a subgroup of participants reported new, late onset neuropathic symptoms (23/262; 9%). Prevalence of neuropathic symptoms was similar between the screening tools when the lower cut-off painDETECT score (≥ 13) was applied. Overall, mean neuropathic pain scores improved between three and 15 months after TKA. Conclusion. Neuropathic pain is common in patients with chronic pain at three months after TKA. Although neuropathic symptoms improved over time, up to half continued to report painful neuropathic symptoms at 15 months after TKA. Postoperative care should include screening, assessment, and treatment of neuropathic pain in patients with early chronic postoperative pain after TKA. Cite this article: Bone Joint J 2024;106-B(6):582–588


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 929 - 937
1 Aug 2022
Gurung B Liu P Harris PDR Sagi A Field RE Sochart DH Tucker K Asopa V

Aims. Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are common orthopaedic procedures requiring postoperative radiographs to confirm implant positioning and identify complications. Artificial intelligence (AI)-based image analysis has the potential to automate this postoperative surveillance. The aim of this study was to prepare a scoping review to investigate how AI is being used in the analysis of radiographs following THA and TKA, and how accurate these tools are. Methods. The Embase, MEDLINE, and PubMed libraries were systematically searched to identify relevant articles. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for scoping reviews and Arksey and O’Malley framework were followed. Study quality was assessed using a modified Methodological Index for Non-Randomized Studies tool. AI performance was reported using either the area under the curve (AUC) or accuracy. Results. Of the 455 studies identified, only 12 were suitable for inclusion. Nine reported implant identification and three described predicting risk of implant failure. Of the 12, three studies compared AI performance with orthopaedic surgeons. AI-based implant identification achieved AUC 0.992 to 1, and most algorithms reported an accuracy > 90%, using 550 to 320,000 training radiographs. AI prediction of dislocation risk post-THA, determined after five-year follow-up, was satisfactory (AUC 76.67; 8,500 training radiographs). Diagnosis of hip implant loosening was good (accuracy 88.3%; 420 training radiographs) and measurement of postoperative acetabular angles was comparable to humans (mean absolute difference 1.35° to 1.39°). However, 11 of the 12 studies had several methodological limitations introducing a high risk of bias. None of the studies were externally validated. Conclusion. These studies show that AI is promising. While it already has the ability to analyze images with significant precision, there is currently insufficient high-level evidence to support its widespread clinical use. Further research to design robust studies that follow standard reporting guidelines should be encouraged to develop AI models that could be easily translated into real-world conditions. Cite this article: Bone Joint J 2022;104-B(8):929–937


Aims. The aim of this study was to compare the migration of the femoral component, five years postoperatively, between patients with a highly cross-linked polyethylene (HXLPE) insert and those with a conventional polyethylene (PE) insert in an uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary aims included clinical outcomes and patient-reported outcome measures (PROMs). We have previously reported the migration and outcome of the tibial components in these patients. Methods. A double-blinded randomized controlled trial was conducted including 96 TKAs. The migration of the femoral component was measured with radiostereometry (RSA) at three and six months and one, two, and five years postoperatively. PROMs were collected preoperatively and at all periods of follow-up. Results. There was no clinically relevant difference in terms of migration of the femoral component or PROMs between the HXLPE and PE groups. The mean difference in migration (maximum total point motion), five years postopeatively, was 0.04 mm (95% CI -0.06 to 0.16) in favour of the PE group. Conclusion. There was no clinically relevant difference in migration of the femoral component, for up to five years between the two groups. These findings will help to establish a benchmark for future studies on migration of femoral components in TKA. Cite this article: Bone Joint J 2024;106-B(8):826–833


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 129 - 137
1 Jun 2020
Knowlton CB Lundberg HJ Wimmer MA Jacobs JJ

Aims. A retrospective longitudinal study was conducted to compare directly volumetric wear of retrieved polyethylene inserts to predicted volumetric wear modelled from individual gait mechanics of total knee arthroplasty (TKA) patients. Methods. In total, 11 retrieved polyethylene tibial inserts were matched with gait analysis testing performed on those patients. Volumetric wear on the articular surfaces was measured using a laser coordinate measure machine and autonomous reconstruction. Knee kinematics and kinetics from individual gait trials drove computational models to calculate medial and lateral tibiofemoral contact paths and forces. Sliding distance along the contact path, normal forces and implantation time were used as inputs to Archard’s equation of wear to predict volumetric wear from gait mechanics. Measured and modelled wear were compared for each component. Results. Volumetric wear rates on eight non-delaminated components measured 15.9 mm. 3. /year (standard error (SE) ± 7.7) on the total part, 11.4 mm. 3. /year (SE ± 6.4) on the medial side and 4.4 (SE ± 2.6) mm. 3. /year on the lateral side. Volumetric wear rates modelled from patient gait mechanics predicted 16.4 mm. 3. /year (SE 2.4) on the total part, 11.7 mm. 3. /year (SE 2.1) on the medial side and 4.7 mm. 3. /year (SE 0.4) on the lateral side. Measured and modelled wear volumes correlated significantly on the total part (p = 0.017) and the medial side (p = 0.012) but not on the lateral side (p = 0.154). Conclusion. In the absence of delamination, patient-specific knee mechanics during gait directly affect wear of the tibial component in TKA. Cite this article: Bone Joint J 2020;102-B(6 Supple A):129–137


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 573 - 581
1 Jun 2024
van Houtert WFC Strijbos DO Bimmel R Krijnen WP Jager J van Meeteren NLU van der Sluis G

Aims

To investigate the impact of consecutive perioperative care transitions on in-hospital recovery of patients who had primary total knee arthroplasty (TKA) over an 11-year period.

Methods

This observational cohort study used electronic health record data from all patients undergoing preoperative screening for primary TKA at a Northern Netherlands hospital between 2009 and 2020. In this timeframe, three perioperative care transitions were divided into four periods: Baseline care (Joint Care, n = 171; May 2009 to August 2010), Function-tailored (n = 404; September 2010 to October 2013), Fast-track (n = 721; November 2013 to May 2018), and Prehabilitation (n = 601; June 2018 to December 2020). In-hospital recovery was measured using inpatient recovery of activities (IROA), length of stay (LOS), and discharge to preoperative living situation (PLS). Multivariable regression models were used to analyze the impact of each perioperative care transition on in-hospital recovery.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 133 - 134
1 Nov 2013
Parvizi J Diaz-Ledezma C

Total knee replacement (TKR) is an operation that can be performed with or without the use of a tourniquet. Meta-analyses of the available Level-1 studies have demonstrated that the use of a tourniquet leads to a significant reduction in blood loss. The opponents for use of a tourniquet cite development of complications such as skin bruising, neurovascular injury, and metabolic disturbance as drawbacks. Although there may certainly be reason for concern in arteriopathic patients, there is little evidence that routine use of a tourniquet during TKR results in any of the above complications. The use of a tourniquet, on the other hand, provides a bloodless field that allows the surgeon to perform the procedure with expediency and optimal visualisation. Blood conservation has gained great importance in recent years due to increased understanding of the problems associated with blood transfusion, such as increased surgical site infection (due to immunomodulation effect), increased length of hospital stay and increased cost. Based on the authors’ understanding of the available evidence, the routine use of a tourniquet during TKR is justified as good surgical practice. . Cite this article: Bone Joint J 2013;95-B, Supple A:133–4


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1511 - 1516
1 Nov 2012
Chang CB Cho W

In a prospective multicentre study we investigated variations in pain management used by knee arthroplasty surgeons in order to compare the differences in pain levels among patients undergoing total knee replacements (TKR), and to compare the effectiveness of pain management protocols. The protocols, peri-operative levels of pain and patient satisfaction were investigated in 424 patients who underwent TKR in 14 hospitals. The protocols were highly variable and peri-operative pain levels varied substantially, particularly during the first two post-operative days. Differences in levels of pain were greatest during the night after TKR, when visual analogue scores ranged from 16.9 to 94.3 points. Of the methods of managing pain, the combined use of peri-articular infiltration and nerve blocks provided better pain relief than other methods during the first two post-operative days. Patients managed with peri-articular injection plus nerve block, and epidural analgesia were more likely to have higher satisfaction at two weeks after TKR. This study highlights the need to establish a consistent pain management strategy after TKR


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 907 - 913
1 Jul 2014
Dossett HG Estrada NA Swartz GJ LeFevre GW Kwasman BG

We have previously reported the short-term radiological results of a randomised controlled trial comparing kinematically aligned total knee replacement (TKR) and mechanically aligned TKR, along with early pain and function scores. In this study we report the two-year clinical results from this trial. A total of 88 patients (88 knees) were randomly allocated to undergo either kinematically aligned TKR using patient-specific guides, or mechanically aligned TKR using conventional instruments. They were analysed on an intention-to-treat basis. The patients and the clinical evaluator were blinded to the method of alignment. At a minimum of two years, all outcomes were better for the kinematically aligned group, as determined by the mean Oxford knee score (40 (15 to 48) versus 33 (13 to 48); p = 0.005), the mean Western Ontario McMaster Universities Arthritis index (WOMAC) (15 (0 to 63) versus 26 (0 to 73); p = 0.005), mean combined Knee Society score (160 (93 to 200) versus 137 (64 to 200); p= 0.005) and mean flexion of 121° (100 to 150) versus 113° (80 to 130) (p = 0.002). The odds ratio of having a pain-free knee at two years with the kinematically aligned technique (Oxford and WOMAC pain scores) was 3.2 (p = 0.020) and 4.9 (p = 0.001), respectively, compared with the mechanically aligned technique. Patients in the kinematically aligned group walked a mean of 50 feet further in hospital prior to discharge compared with the mechanically aligned group (p = 0.044). In this study, the use of a kinematic alignment technique performed with patient-specific guides provided better pain relief and restored better function and range of movement than the mechanical alignment technique performed with conventional instruments. Cite this article: Bone Joint J 2014;96-B:907–13


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 932 - 936
1 Jul 2012
Lin P Hsu C Huang C Chen W Wang J

Tranexamic acid (TEA), an inhibitor of fibrinolysis, reduces blood loss after routine total knee replacement (TKR). However, controversy persists regarding the dosage and timing of administration of this drug during surgery. We performed a prospective randomised controlled study to examine the optimum blood-saving effect of TEA in minimally invasive TKR. We randomly assigned 151 patients who underwent unilateral minimally invasive TKR to three groups: 1) a placebo group (50 patients); 2) a one-dose TEA group (52 patients), who received one injection of TEA (10 mg/kg) intra-operatively on deflation of the tourniquet; and 3) a two-dose TEA group (49 patients), who received two injections of TEA (10 mg/kg) given pre-operatively and intra-operatively. Total blood loss was calculated from the maximum loss of haemoglobin. All patients were followed clinically for the presence of venous thromboembolism (VTE). The mean total blood loss was significantly higher in the placebo group than in the other two groups (1222 ml (845 to 2043) versus 1035 ml (397 to 1934) and 986 ml (542 to 1811), respectively (both p < 0.0001)). The mean blood loss was not significantly different between the one- and two-TEA groups (p = 0.148). The mean transfusion rate was higher in the placebo group than in the other two groups (22% versus 3.8% (p = 0.006) and 6.1% (p = 0.041), respectively) and there was no statistically significant difference in the mean transfusion rate between the one- and two-TEA groups (p = 0.672). Only one patient, in the two-dose group, had a radiologically confirmed deep venous thrombosis. Our prospective randomised controlled study showed that one intra-operative injection of TEA is effective for blood conservation after minimally invasive TKR


Bone & Joint Research
Vol. 1, Issue 10 | Pages 263 - 271
1 Oct 2012
Sharma GB Saevarsson SK Amiri S Montgomery S Ramm H Lichti DD Lieck R Zachow S Anglin C

Objectives. Numerous complications following total knee replacement (TKR) relate to the patellofemoral (PF) joint, including pain and patellar maltracking, yet the options for in vivo imaging of the PF joint are limited, especially after TKR. We propose a novel sequential biplane radiological method that permits accurate tracking of the PF and tibiofemoral (TF) joints throughout the range of movement under weightbearing, and test it in knees pre- and post-arthroplasty. Methods. A total of three knees with end-stage osteoarthritis and three knees that had undergone TKR at more than one year’s follow-up were investigated. In each knee, sequential biplane radiological images were acquired from the sagittal direction (i.e. horizontal X-ray source and 10° below horizontal) for a sequence of eight flexion angles. Three-dimensional implant or bone models were matched to the biplane images to compute the six degrees of freedom of PF tracking and TF kinematics, and other clinical measures. Results. The mean and standard deviation for the six degrees of freedom of PF tracking and TF kinematics were computed. TF and PF kinematics were highly accurate (< 0.9 mm, < 0.6°) and repeatable. Conclusions. The developed method permitted measuring of in vivo PF tracking and TF kinematics before and after TKR throughout the range of movement. This method could be a useful tool for investigating differences between cohorts of patients (e.g., with and without pain) impacting clinical decision-making regarding surgical technique, revision surgery or implant design


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 609 - 618
1 May 2014
Gøthesen Ø Espehaug B Havelin LI Petursson G Hallan G Strøm E Dyrhovden G Furnes O

We performed a randomised controlled trial comparing computer-assisted surgery (CAS) with conventional surgery (CONV) in total knee replacement (TKR). Between 2009 and 2011 a total of 192 patients with a mean age of 68 years (55 to 85) with osteoarthritis or arthritic disease of the knee were recruited from four Norwegian hospitals. At three months follow-up, functional results were marginally better for the CAS group. Mean differences (MD) in favour of CAS were found for the Knee Society function score (MD: 5.9, 95% confidence interval (CI) 0.3 to 11.4, p = 0.039), the Knee Injury and Osteoarthritis Outcome Score (KOOS) subscales for ‘pain’ (MD: 7.7, 95% CI 1.7 to 13.6, p = 0.012), ‘sports’ (MD: 13.5, 95% CI 5.6 to 21.4, p = 0.001) and ‘quality of life’ (MD: 7.2, 95% CI 0.1 to 14.3, p = 0.046). At one-year follow-up, differences favouring CAS were found for KOOS ‘sports’ (MD: 11.0, 95% CI 3.0 to 19.0, p = 0.007) and KOOS ‘symptoms’ (MD: 6.7, 95% CI 0.5 to 13.0, p = 0.035). The use of CAS resulted in fewer outliers in frontal alignment (> 3° malalignment), both for the entire TKR (37.9% vs 17.9%, p = 0.042) and for the tibial component separately (28.4% vs 6.3%, p = 0.002). Tibial slope was better achieved with CAS (58.9% vs 26.3%, p < 0.001). Operation time was 20 minutes longer with CAS. In conclusion, functional results were, statistically, marginally in favour of CAS. Also, CAS was more predictable than CONV for mechanical alignment and positioning of the prosthesis. However, the long-term outcomes must be further investigated. Cite this article: Bone Joint J 2014; 96-B:609–18


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 493 - 497
1 Apr 2013
Hino K Ishimaru M Iseki Y Watanabe S Onishi Y Miura H

There are several methods for evaluating stability of the joint during total knee replacement (TKR). Activities of daily living demand mechanical loading to the knee joint, not only in full extension, but also in mid-flexion. The purpose of this study was to compare the varus-valgus stability throughout flexion in knees treated with either cruciate-retaining or posterior-stabilised TKR, using an intra-operative navigation technique. A total of 34 knees underwent TKR with computer navigation, during which the investigator applied a maximum varus-valgus stress to the knee while steadily moving the leg from full extension to flexion both before and after prosthetic implantation. The femorotibial angle was measured simultaneously by the navigation system at every 10° throughout the range of movement. It was found that posterior-stabilised knees had more varus-valgus laxity than cruciate-retaining knees at all angles examined, and the differences were statistically significant at 10° (p = 0.0093), 20° (p = 0.0098) and 30° of flexion (p = 0.0252). Cite this article: Bone Joint J 2013;95-B:493–7


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1228 - 1233
1 Sep 2012
Baliga S McNair CJ Barnett KJ MacLeod J Humphry RW Finlayson D

The incidence of anterior knee pain following total knee replacement (TKR) is reported to be as high as 49%. The source of the pain is poorly understood but the soft tissues around the patella have been implicated. In theory circumferential electrocautery denervates the patella thereby reducing efferent pain signals. However, there is mixed evidence that this practice translates into improved outcomes. We aimed to investigate the clinical effect of intra-operative circumpatellar electrocautery in patients undergoing TKR using the LCS mobile bearing or Kinemax fixed bearing TKR. A total of 200 patients were randomised to receive either circumpatellar electrocautery (diathermy) or not (control). Patients were assessed by visual analogue scale (VAS) for anterior knee pain and Oxford knee score (OKS) pre-operatively and three months, six months and one year post-operatively. Patients and assessors were blinded. There were 91 patients in the diathermy group and 94 in the control. The mean VAS improvement at one year was 3.9 in both groups (control; -10 to 6, diathermy;. -9 to 8, p < 0.001 in both cases, paired, two-tailed t-test). There was no significant difference in VAS between the groups at any other time. The mean OKS improvement was 17.7 points (0 to 34) in the intervention group and 16.6 (0 to 42) points in the control (p = 0.36). There was no significant difference between the two groups in OKS at any other time. We found no relevant effect of patellar electrocautery on either VAS anterior knee pain or OKS for patients undergoing LCS and Kinemax TKR


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 120 - 123
1 Nov 2013
Drexler M Dwyer T Chakravertty R Farno A Backstein D

Total knee replacement (TKR) is one of the most common operations in orthopaedic surgery worldwide. Despite its scientific reputation as mainly successful, only 81% to 89% of patients are satisfied with the final result. Our understanding of this discordance between patient and surgeon satisfaction is limited. In our experience, focus on five major factors can improve patient satisfaction rates: correct patient selection, setting of appropriate expectations, avoiding preventable complications, knowledge of the finer points of the operation, and the use of both pre- and post-operative pathways. Awareness of the existence, as well as the identification of predictors of patient–surgeon discordance should potentially help with enhancing patient outcomes. Cite this article: Bone Joint J 2013;95-B, Supple A:120–3


Bone & Joint Research
Vol. 2, Issue 4 | Pages 70 - 78
1 Apr 2013
Hamilton DF McLeish JA Gaston P Simpson AHRW

Objectives. Lower limb muscle power is thought to influence outcome following total knee replacement (TKR). Post-operative deficits in muscle strength are commonly reported, although not explained. We hypothesised that post-operative recovery of lower limb muscle power would be influenced by the number of satellite cells in the quadriceps muscle at time of surgery. . Methods. Biopsies were obtained from 29 patients undergoing TKR. Power output was assessed pre-operatively and at six and 26 weeks post-operatively with a Leg Extensor Power Rig and data were scaled for body weight. Satellite cell content was assessed in two separate analyses, the first cohort (n = 18) using immunohistochemistry and the second (n = 11) by a new quantitative polymerase chain reaction (q-PCR) protocol for Pax-7 (generic satellite cell marker) and Neural Cell Adhesion Molecule (NCAM; marker of activated cells). Results. A significant improvement in power output was observed post-operatively with a mean improvement of 19.7 W (95% confidence interval (CI) 14.43 to 30.07; p < 0.001) in the first cohort and 27.5 W (95% CI 13.2 to 41.9; p = 0.002) in the second. A strong correlation was noted between satellite cell number (immunohistochemistry) and improvement in patient power output (r = 0.64, p = 0.008). Strong correlation was also observed between the expression of Pax-7 and power output (r = 0.79, p = 0.004), and the expression of NCAM and power output (r = 0.84, p = 0.001). The generic marker explained 58% of the variation in power output, and the marker of activated cells 67%. Conclusions. Muscle satellite cell content may determine improvement in lower limb power generation (and thus function) following TKR


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1204 - 1208
1 Sep 2013
Kerens B Boonen B Schotanus MGM Lacroix H Emans PJ Kort NP

Although it has been suggested that the outcome after revision of a unicondylar knee replacement (UKR) to total knee replacement (TKR) is better when the mechanism of failure is understood, a comparative study on this subject has not been undertaken. A total of 30 patients (30 knees) who underwent revision of their unsatisfactory UKR to TKR were included in the study: 15 patients with unexplained pain comprised group A and 15 patients with a defined cause for pain formed group B. The Oxford knee score (OKS), visual analogue scale for pain (VAS) and patient satisfaction were assessed before revision and at one year after revision, and compared between the groups. The mean OKS improved from 19 (10 to 30) to 25 (11 to 41) in group A and from 23 (11 to 45) to 38 (20 to 48) in group B. The mean VAS improved from 7.7 (5 to 10) to 5.4 (1 to 8) in group A and from 7.4 (2 to 9) to 1.7 (0 to 8) in group B. There was a statistically significant difference between the mean improvements in each group for both OKS (p = 0.022) and VAS (p = 0.002). Subgroup analysis in group A, performed in order to define a patient factor that predicts outcome of revision surgery in patients with unexplained pain, showed no pre-operative differences between both subgroups. These results may be used to inform patients about what to expect from revision surgery, highlighting that revision of UKR to TKR for unexplained pain generally results in a less favourable outcome than revision for a known cause of pain. Cite this article: Bone Joint J 2013;95-B:1204–8


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1067 - 1070
1 Aug 2012
Melton JTK Mayahi R Baxter SE Facek M Glezos C

A consecutive series of patients with a hydroxyapatite-coated uncemented total knee replacement (TKR) performed by a single surgeon between 1992 and 1995 was analysed. All patients were invited for clinical review and radiological assessment. Revision for aseptic loosening was the primary outcome. Assessment was based on the Knee Society clinical score (KSS) and an independent radiological analysis. Of 471 TKRs performed in 356 patients, 432 TKRs in 325 patients were followed for a mean of 16.4 years (15 to 18). The 39 TKRs in 31 patients lost to follow-up had a mean KSS of 176 (148 to 198) at a mean of ten years. There were revisions in 26 TKRs (5.5%), of which 11 (2.3%) were for aseptic loosening. Other further surgery was carried out on 49 TKRs (10.4%) including patellar resurfacing in 20, arthrolysis in 19, manipulation under anaesthetic in nine and extensor mechanism reconstruction in one. Survivorship at up to 18 years without aseptic loosening was 96% (95% confidence interval 91.9 to 98.1), at which point the mean KSS was 176 (134 to 200). Of 110 knees that underwent radiological evaluation, osteolysis was observed in five (4.5%), one of which was revised. These data indicate that uncemented hydroxyapatite-coated TKR can achieve favourable long-term survivorship, at least as good as that of cemented designs


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1457 - 1461
1 Nov 2012
Krishnan SP Dawood A Richards R Henckel J Hart AJ

Improvements in the surgical technique of total knee replacement (TKR) are continually being sought. There has recently been interest in three-dimensional (3D) pre-operative planning using magnetic resonance imaging (MRI) and CT. The 3D images are increasingly used for the production of patient-specific models, surgical guides and custom-made implants for TKR. The users of patient-specific instrumentation (PSI) claim that they allow the optimum balance of technology and conventional surgery by reducing the complexity of conventional alignment and sizing tools. In this way the advantages of accuracy and precision claimed by computer navigation techniques are achieved without the disadvantages of additional intra-operative inventory, new skills or surgical time. This review describes the terminology used in this area and debates the advantages and disadvantages of PSI


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 486 - 492
1 Apr 2013
Breeman S Campbell MK Dakin H Fiddian N Fitzpatrick R Grant A Gray A Johnston L MacLennan GS Morris RW Murray DW

There is conflicting evidence about the merits of mobile bearings in total knee replacement, partly because most randomised controlled trials (RCTs) have not been adequately powered. We report the results of a multicentre RCT of mobile versus fixed bearings. This was part of the knee arthroplasty trial (KAT), where 539 patients were randomly allocated to mobile or fixed bearings and analysed on an intention-to-treat basis. The primary outcome measure was the Oxford Knee Score (OKS) plus secondary measures including Short Form-12, EuroQol EQ-5D, costs, cost-effectiveness and need for further surgery. There was no significant difference between the groups pre-operatively: mean OKS was 17.18 (. sd. 7.60) in the mobile-bearing group and 16.49 (. sd. 7.40) in the fixed-bearing group. At five years mean OKS was 33.19 (. sd. 16.68) and 33.65 (. sd. 9.68), respectively. There was no significant difference between trial groups in OKS at five years (-1.12 (95% confidence interval -2.77 to 0.52) or any of the other outcome measures. Furthermore, there was no significant difference in the proportion of patients with knee-related re-operations or in total costs. In this appropriately powered RCT, over the first five years after total knee replacement functional outcomes, re-operation rates and healthcare costs appear to be the same irrespective of whether a mobile or fixed bearing is used. Cite this article: Bone Joint J 2013;95-B:486–92


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 56 - 61
1 Jan 2012
Kawahara S Matsuda S Fukagawa S Mitsuyasu H Nakahara H Higaki H Shimoto T Iwamoto Y

In posterior stabilised total knee replacement (TKR) a larger femoral component is sometimes selected to manage the increased flexion gap caused by resection of the posterior cruciate ligament. However, concerns remain regarding the adverse effect of the increased anteroposterior dimensions of the femoral component on the patellofemoral (PF) joint. Meanwhile, the gender-specific femoral component has a narrower and thinner anterior flange and is expected to reduce the PF contact force. PF contact forces were measured at 90°, 120°, 130° and 140° of flexion using the NexGen Legacy Posterior Stabilized (LPS)-Flex Fixed Bearing Knee system using Standard, Upsized and Gender femoral components during TKR. Increasing the size of the femoral component significantly increased mean PF forces at 120°, 130° and 140° of flexion (p = 0.005, p < 0.001 and p < 0.001, respectively). No difference was found in contact force between the Gender and the Standard components. Among the patients who had overhang of the Standard component, mean contact forces with the Gender component were slightly lower than those of the Standard component, but no statistical difference was found at 90°, 120°, 130° or 140° of flexion (p = 0.689, 0.615, 0.253 and 0.248, respectively). Upsized femoral components would increase PF forces in deep knee flexion. Gender-specific implants would not reduce PF forces


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1209 - 1215
1 Sep 2012
Murakami AM Hash TW Hepinstall MS Lyman S Nestor BJ Potter HG

Component malalignment can be associated with pain following total knee replacement (TKR). Using MRI, we reviewed 50 patients with painful TKRs and compared them with a group of 16 asymptomatic controls to determine the feasibility of using MRI in evaluating the rotational alignment of the components. Using the additional soft-tissue detail provided by this modality, we also evaluated the extent of synovitis within these two groups. Angular measurements were based on the femoral transepicondylar axis and tibial tubercle. Between two observers, there was very high interobserver agreement in the measurements of all values. Patients with painful TKRs demonstrated statistically significant relative internal rotation of the femoral component (p = 0.030). There was relative internal rotation of the tibial to femoral component and combined excessive internal rotation of the components in symptomatic knees, although these results were significant only with one of the observers (p = 0.031). There was a statistically significant association between the presence and severity of synovitis and painful TKR (p < 0.001). MRI is an effective modality in evaluating component rotational alignment


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1632 - 1639
1 Dec 2013
Clement ND MacDonald D Simpson AHRW Burnett R

This study assessed the effect of concomitant back pain on the Oxford knee score (OKS), Short-Form (SF)-12 and patient satisfaction after total knee replacement (TKR). It involved a prospectively compiled database of demographics and outcome scores for 2392 patients undergoing primary TKR, of whom 829 patients (35%) reported back pain. Compared with those patients without back pain, those with back pain were more likely to be female (odds ratio (OR) 1.5 (95% confidence interval (CI) 1.3 to 1.8)), have a greater level of comorbidity, a worse pre-operative OKS (2.3 points (95% CI 1.7 to 3.0)) and worse SF-12 physical (2.0 points (95% CI 1.4 to 2.6)) and mental (3.3 points (95% CI 2.3 to 4.3)) components. One year post-operatively, those with back pain had significantly worse outcome scores than those without with a mean difference in the OKS of 5 points (95% CI 3.8 to 5.4), in the SF-12 physical component of 6 points (95% CI 5.4 to 7.1) and in the mental component of 4 points (95% CI 3.1 to 4.9). Patients with back pain were less likely to be satisfied (OR 0.62, 95% CI 0.5 to 0.78). After adjusting for confounding variables, concomitant back pain was an independent predictor of a worse post-operative OKS, and of dissatisfaction. Clinicians should be aware that patients suffering concomitant back pain pre-operatively are at an increased risk of being dissatisfied post-operatively. Cite this article: Bone Joint J 2013;95-B:1632–9


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1222 - 1226
1 Sep 2014
W-Dahl A Sundberg M Lidgren L Ranstam J Robertsson O

We identified a group of patients from the Swedish Arthroplasty Register who reported no relief of pain or worse pain one year after a total knee replacement (TKR). A total of two different patient-reported pain scores were used during this process. We then evaluated how the instruments used to measure pain affected the number of patients who reported no relief of pain or worse pain, and the relative effect of potential risk factors. . Between 2008 and 2010, 2883 TKRs were performed for osteoarthritis in two Swedish arthroplasty units. After applying exclusion criteria, 2123 primary TKRs (2123 patients) were included in the study. The Knee injury and Osteoarthritis Outcome Score (KOOS) and a Visual Analogue Scale (VAS) for knee pain were used to assess patients pre-operatively and one year post-operatively. . Only 50 of the 220 patients (23%) who reported no pain relief on either the KOOS pain subscale or the VAS for knee pain did so with both of these instruments. Patients who reported no pain relief on either measure tended to have less pain pre-operatively but a higher degree of anxiety. Charnley category C was a predictor for not gaining pain relief as measured on a VAS for knee pain. . The number of patients who are not relieved of pain after a TKR differs considerably depending on the instrument used to measure pain. . Cite this article: Bone Joint J 2014;96-B:1222–6


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1234 - 1240
1 Sep 2012
Willcox NMJ Clarke JV Smith BRK Deakin AH Deep K

We compared lower limb coronal alignment measurements obtained pre- and post-operatively with long-leg radiographs and computer navigation in patients undergoing primary total knee replacement (TKR). A series of 185 patients had their pre- and post-implant radiological and computer-navigation system measurements of coronal alignment compared using the Bland-Altman method. The study included 81 men and 104 women with a mean age of 68.5 years (32 to 87) and a mean body mass index of 31.7 kg/m. 2. (19 to 49). Pre-implant Bland–Altman limits of agreement were -9.4° to 8.6° with a repeatability coefficient of 9.0°. The Bland–Altman plot showed a tendency for the radiological measurement to indicate a higher level of pre-operative deformity than the corresponding navigation measurement. Post-implant limits of agreement were -5.0° to 5.4° with a repeatability coefficient of 5.2°. The tendency for valgus knees to have greater deformity on the radiograph was still seen, but was weaker for varus knees. . The alignment seen or measured intra-operatively during TKR is not necessarily the same as the deformity seen on a standing long-leg radiograph either pre- or post-operatively. Further investigation into the effect of weight-bearing and surgical exposure of the joint on the mechanical femorotibial angle is required to enable the most appropriate intra-operative alignment to be selected


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1058 - 1066
1 Aug 2012
Baker PN Deehan DJ Lees D Jameson S Avery PJ Gregg PJ Reed MR

Patient-reported outcome measures (PROMs) are increasingly being used to assess functional outcome and patient satisfaction. They provide a framework for comparisons between surgical units, and individual surgeons for benchmarking and financial remuneration. Better performance may bring the reward of more customers as patients and commissioners seek out high performers for their elective procedures. Using National Joint Registry (NJR) data linked to PROMs we identified 22 691 primary total knee replacements (TKRs) undertaken for osteoarthritis in England and Wales between August 2008 and February 2011, and identified the surgical factors that influenced the improvements in the Oxford knee score (OKS) and EuroQol-5D (EQ-5D) assessment using multiple regression analysis. After correction for patient factors the only surgical factors that influenced PROMs were implant brand and hospital type (both p < 0.001). However, the effects of surgical factors upon the PROMs were modest compared with patient factors. For both the OKS and the EQ-5D the most important factors influencing the improvement in PROMs were the corresponding pre-operative score and the patient’s general health status. Despite having only a small effect on PROMs, this study has shown that both implant brand and hospital type do influence reported subjective functional scores following TKR. In the current climate of financial austerity, proposed performance-based remuneration and wider patient choice, it would seem unwise to ignore these effects and the influence of a range of additional patient factors


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 472 - 477
1 Apr 2013
Liebs T Kloos S Herzberg W Rüther W Hassenpflug J

We investigated whether an asymmetric extension gap seen on routine post-operative radiographs after primary total knee replacement (TKR) is associated with pain at three, six, 12 and 24 months’ follow-up. On radiographs of 277 patients after primary TKR we measured the distance between the tibial tray and the femoral condyle on both the medial and lateral sides. A difference was defined as an asymmetric extension gap. We considered three groups (no asymmetric gap, medial-opening and lateral-opening gap) and calculated the associations with the Western Ontario and McMaster Universities osteoarthritis index pain scores over time.

Those with an asymmetric extension gap of ≥ 1.5 mm had a significant association with pain scores at three months’ follow-up; patients with a medial-opening extension gap reported more pain and patients with a lateral-opening extension gap reported less pain (p = 0.036). This effect was still significant at six months (p = 0.044), but had lost significance by 12 months (p = 0.924). When adjusting for multiple cofounders the improvement in pain was more pronounced in patients with a lateral-opening extension gap than in those with a medial-opening extension gap at three (p = 0.037) and six months’ (p = 0.027) follow-up.

Cite this article: Bone Joint J 2013;95-B:472–7.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1497 - 1499
1 Nov 2013
Abram SGF Nicol F Hullin MG Spencer SJ

We reviewed the long-term clinical and radiological results of 63 uncemented Low Contact Stress (LCS) total knee replacements (TKRs) in 47 patients with rheumatoid arthritis. The mean age of the patients at the time of surgery was 69 years (53 to 81). At a mean follow-up of 22 years (20 to 25), 12 patients were alive (17 TKRs), 27 had died (36 TKRs), and eight (ten TKRs) were lost to follow-up.

Revision was necessary in seven patients (seven TKRs, 11.1%) at a mean of 12.1 years (0 to 19) after surgery. In the surviving ten patients who had not undergone revision (15 TKRs), the mean Oxford knee score was 30.2 (16 to 41) at a mean follow-up of 19.5 years (15 to 24.7) and mean active flexion was 105° (90° to 150°). The survival rate was 88.9% at 20 years (56 of 63) and the Kaplan–Meier survival estimate, without revision, was 80.2% (95% confidence interval 37 to 100) at 25 years.

Cite this article: Bone Joint J 2013;95-B:1497–9.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 473 - 478
1 Apr 2014
van Jonbergen HPW Scholtes VAB Poolman RW

In the absence of patellar resurfacing, we have previously shown that the use of electrocautery around the margin of the patella improved the one-year clinical outcome of total knee replacement (TKR). In this prospective randomised study we compared the mean 3.7 year (1.1 to 4.2) clinical outcomes of 300 TKRs performed with and without electrocautery of the patellar rim: this is an update of a previous report. The overall prevalence of anterior knee pain was 32% (95% confidence intervals [CI] 26 to 39), and 26% (95% CI 18 to 35) in the intervention group compared with 38% (95% CI 29 to 48) in the control group (chi-squared test; p = 0.06). The overall prevalence of anterior knee pain remained unchanged between the one-year and 3.7 year follow-up (chi-squared test; p = 0.12). The mean total Western Ontario McMasters Universities Osteoarthritis Indices and the American Knee Society knee and function scores at 3.7 years’ follow-up were similar in the intervention and control groups (repeated measures analysis of variance p = 0.43, p = 0.09 and p = 0.59, respectively). There were no complications. A total of ten patients (intervention group three, control group seven) required secondary patellar resurfacing after the first year.

Our study suggests that the improved clinical outcome with electrocautery denervation compared with no electrocautery is not maintained at a mean of 3.7 years’ follow-up.

Cite this article: Bone Joint J 2014;96-B:473–8.


Aims. The use of high tibial osteotomy (HTO) to delay total knee arthroplasty (TKA) in young patients with osteoarthritis (OA) and constitutional deformity remains debated. The aim of this study was to compare the long-term outcomes of TKA after HTO compared to TKA without HTO, using the time from the index OA surgery as reference (HTO for the study group, TKA for the control group). Methods. This was a case-control study of consecutive patients receiving a posterior-stabilized TKA for OA between 1996 and 2010 with previous HTO. A total of 73 TKAs after HTO with minimum ten years’ follow-up were included. Cases were matched with a TKA without previous HTO for age at the time of the HTO. All revisions were recorded. Kaplan-Meier survivorship analysis was performed using revision of metal component as the endpoint. The Knee Society Score, range of motion, and patient satisfaction were assessed. Results. Mean follow-up was 13 years (SD 3) after TKA in both groups. The 20-year Kaplan-Meier survival estimate was 98.6% in TKA post-HTO group (HTO as timing reference) and 81.4% in control group (TKA as timing reference) (p = 0.030). There was no significant difference in clinical outcomes, radiological outcomes, and complications at the last follow-up. Conclusion. At the same delay from index surgery (HTO or TKA), a strategy of HTO followed by TKA had superior knee survivorship compared to early TKA at long term in young patients. Level of evidence: III. Cite this article: Bone Jt Open 2023;4(2):62–71


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 782 - 787
1 Jun 2013
Niki Y Takeda Y Udagawa K Enomoto H Toyama Y Suda Y

We investigated the characteristics of patients who achieved Japanese-style deep flexion (seiza-sitting) after total knee replacement (TKR) and measured three-dimensional positioning and the contact positions of the femoral and tibial components. Seiza-sitting was achieved after surgery by 23 patients (29 knees) of a series of 463 TKRs in 341 patients. Pre-operatively most of these patients were capable of seiza-sitting, had a lower body mass index and a favourable attitude towards the Japanese lifestyle (27 of 29 knees). According to two-/three-dimensional image registration analysis in the seiza-sitting position, flexion, varus and internal rotation angles of the tibial component relative to the femoral component had means of 148° (sd 8.0), 1.9° (sd 3.2) and 13.4° (sd 5.9), respectively. Femoral surface contact positions tended to be close to the posterior edge of the tibial polyethylene insert, particularly in the lateral compartment, but only 8.3% (two of 24) of knees showed femoral subluxation over the posterior edge. The mean contact positions of the femoral cam on the tibial post were located 7.8 mm (sd 1.5) proximal to the lowest point of the polyethylene surface and 5.5 mm (sd 0.9) medial to the centre of the post, indicating that the post-cam contact position translated medially during seiza-sitting, but not proximally. Collectively, the seiza-sitting position seems safe against component dislocation, but the risks of posterior edge loading and breakage of the tibial polyethylene post remain.

Cite this article: Bone Joint J 2013;95-B:782–7.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_14 | Pages 1 - 1
10 Oct 2023
Haque S Downie S Ridley D Dalgleish S Nicol G
Full Access

There is little published literature to support the claim that a successful total knee replacement (TKR) is predictive of future good outcomes on the contralateral side. The objective was to identify whether outcome from the first of staged TKRs could be used to predict the outcome of the contralateral TKR. This was a retrospective cohort study of 1687 patients over a 25-year period undergoing staged bilateral TKRs in a UK arthroplasty centre. A control group of 1687 patients undergoing unilateral TKR with matched characteristics was identified. Primary outcomes were satisfaction and Knee Society Score (KSS) at one year. Preoperative status was comparable for pain, ROM and KSS (mean 41, 45, 43±14). At one year follow up, dissatisfaction was similar for all groups (4% first of staged TKR, 4% second of staged TKR, 5% controls). If the first TKR had a good outcome, the relative risk of a contralateral bad outcome was 20% less than controls (95% CI 0.6–1.2). If the first TKR had a poor outcome, the risk of a second poor outcome was 4 times higher (95% CI 2.8–6.1), increasing from 6% to 27% (absolute risk). Patients undergoing the second of staged TKRs with a previous good outcome are likely to do well in their second procedure (94 in 100 will go on to have a second good outcome). Of those with a previous poor outcome, 27 in 100 will have a second poor outcome. The trend was persistent despite correcting for gender, age, BMI, and diagnosis


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 6 - 6
10 May 2024
Zaidi F Bolam S Goplen C Yeung T Lovatt M Hanlon M Munro J Besier T Monk A
Full Access

Introduction. Robotic-assisted total knee arthroplasty (TKA) has demonstrated significant benefits, including improved accuracy of component positioning compared to conventional jig-based TKA. However, previous studies have often failed to associate these findings with clinically significant improvements in patient-reported outcome measures (PROMs). Inertial measurement units (IMUs) provide a more nuanced assessment of a patient's functional recovery after TKA. This study aims to compare outcomes of patients undergoing robotic-assisted and conventional TKA in the early postoperative period using conventional PROMS and wearable sensors. Method. 100 patients with symptomatic end-stage knee osteoarthritis undergoing primary TKA were included in this study (44 robotic-assisted TKA and 56 conventional TKA). Functional outcomes were assessed using ankle-worn IMUs and PROMs. IMU- based outcomes included impact load, impact asymmetry, maximum knee flexion angle, and bone stimulus. PROMs, including Oxford Knee Score (OKS), EuroQol-Five Dimension (EQ-5D-5L), EuroQol Visual Analogue Scale (EQ-VAS), and Forgotten Joint Score (FJS-12) were evaluated at preoperative baseline, weeks 2 to 6 postoperatively, and at 3-month postoperative follow-up. Results. By postoperative week 6, when compared to conventional TKA, robotic-assisted TKA was associated with significant improvements in maximum knee flexion angle (118o ± 6.6 vs. 113o ± 5.4; p=0.04), symmetrical loading of limbs (82.3% vs.22.4%; p<0.01), cumulative impact load (146.6% vs 37%; p<0.01), and bone stimulus (25.1% vs 13.6%; p<0.01). Whilst there were no significant differences in PROMs (OKS, EQ-5D-5L, EQ-VAS, and FJS-12) at any time point between the two groups, when comparing OKS subscales, significantly more robotic-assisted TKA patients achieved an ‘excellent’ outcome at 6 weeks compared to conventional (47% vs 41%, p= 0.013). Conclusions. IMU-based metrics detected an earlier return to function among patients that underwent robotic-assisted TKA compared to conventional TKA that PROMs were unable to detect within the first six weeks of surgery


Bone & Joint Open
Vol. 3, Issue 3 | Pages 211 - 217
1 Mar 2022
Hsu C Chen C Wang S Huang J Tong K Huang K

Aims. The Coronal Plane Alignment of the Knee (CPAK) classification is a simple and comprehensive system for predicting pre-arthritic knee alignment. However, when the CPAK classification is applied in the Asian population, which is characterized by more varus and wider distribution in lower limb alignment, modifications in the boundaries of arithmetic hip-knee-ankle angle (aHKA) and joint line obliquity (JLO) should be considered. The purposes of this study were as follows: first, to propose a modified CPAK classification based on the actual joint line obliquity (aJLO) and wider range of aHKA in the Asian population; second, to test this classification in a cohort of Asians with healthy knees; third, to propose individualized alignment targets for different CPAK types in kinematically aligned (KA) total knee arthroplasty (TKA). Methods. The CPAK classification was modified by changing the neutral boundaries of aHKA to 0° ± 3° and using aJLO as a new variable. Radiological analysis of 214 healthy knees in 214 Asian individuals was used to assess the distribution and mean value of alignment angles of each phenotype among different classifications based on the coronal plane. Individualized alignment targets were set according to the mean lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA) of different knee types. Results. A very high concentration, 191 from 214 individuals (89.3%), were found in knee types with apex distal JLO when the CPAK classification was applied in the Asian population. By using aJLO as a new variable, the high distribution percentage in knee types with apex distal JLO decreased to 125 from 214 individuals (58.4%). The most common types in order were Type II (n = 70; 32.7%), Type V (n = 55; 25.7%), and Type I (n = 46; 21.5%) in the modified CPAK classification. Conclusion. The modified CPAK classification corrected the uneven distribution when applying the CPAK classification in the Asian population. Setting individualized TKA alignment targets according to CPAK type may be a practical method to recreate optimal LDFA and MPTA in KA-TKA. Cite this article: Bone Jt Open 2022;3(3):211–217


Aims. The primary objective of this study was to compare the five-year tibial component migration and wear between highly crosslinked polyethylene (HXLPE) inserts and conventional polyethylene (PE) inserts of the uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary objectives included clinical outcomes and patient-reported outcome measures (PROMs). Methods. A double-blinded, randomized study was conducted including 96 TKAs. Tibial component migration and insert wear were measured with radiostereometric analysis (RSA) at three, six, 12, 24, and 60 months postoperatively. PROMS were collected preoperatively and at all follow-up timepoints. Results. There was no clinically relevant difference in terms of tibial component migration, insert wear, and PROMs between the HXLPE and PE groups. The mean difference in tibial component migration (maximal total point migration (MTPM)) was 0.02 mm (95% confidence interval (CI) -0.07 to 0.11), which is below the value of 0.2 mm considered to be clinically relevant. Wear after five years for HXLPE was 0.16 mm (95% CI 0.05 to 0.27), and for PE was 0.23 mm (95% CI 0.12 to 0.35). The mean difference in wear rate was 0.01 mm/year (95% CI -0.02 to 0.05) in favour of the HXLPE group. Wear is mainly present on the medial side of the insert. Conclusion. There is no clinically relevant difference in tibial component migration and insert wear for up to five years between the HXLPE conventional PE inserts. For the implant studied, the potential advantages of a HXLPE insert remain to be proven under clinical conditions at longer-term follow-up. Cite this article: Bone Joint J 2023;105-B(5):518–525


Bone & Joint Open
Vol. 3, Issue 7 | Pages 589 - 595
1 Jul 2022
Joo PY Chen AF Richards J Law TY Taylor K Marchand K Clark G Collopy D Marchand RC Roche M Mont MA Malkani AL

Aims. The aim of this study was to report patient and clinical outcomes following robotic-assisted total knee arthroplasty (RA-TKA) at multiple institutions with a minimum two-year follow-up. Methods. This was a multicentre registry study from October 2016 to June 2021 that included 861 primary RA-TKA patients who completed at least one pre- and postoperative patient-reported outcome measure (PROM) questionnaire, including Forgotten Joint Score (FJS), Knee Injury and Osteoarthritis Outcomes Score for Joint Replacement (KOOS JR), and pain out of 100 points. The mean age was 67 years (35 to 86), 452 were male (53%), mean BMI was 31.5 kg/m. 2. (19 to 58), and 553 (64%) cemented and 308 (36%) cementless implants. Results. There were significant improvements in PROMs over time between preoperative, one- to two-year, and > two-year follow-up, with a mean FJS of 17.5 (SD 18.2), 70.2 (SD 27.8), and 76.7 (SD 25.8; p < 0.001); mean KOOS JR of 51.6 (SD 11.5), 85.1 (SD 13.8), and 87.9 (SD 13.0; p < 0.001); and mean pain scores of 65.7 (SD 20.4), 13.0 (SD 19.1), and 11.3 (SD 19.9; p < 0.001), respectively. There were eight superficial infections (0.9%) and four revisions (0.5%). Conclusion. RA-TKA demonstrated consistent clinical results across multiple institutions with excellent PROMs that continued to improve over time. With the ability to achieve target alignment in the coronal, axial, and sagittal planes and provide intraoperative real-time data to obtain balanced gaps, RA-TKA demonstrated excellent clinical outcomes and PROMs in this patient population. Cite this article: Bone Jt Open 2022;3(7):589–595


Full Access

Abstract. INTRODUCTION. 10% of patients with knee osteoarthritis (OA) have disease confined to the patellofemoral joint (PFJ). The main surgical options are total knee replacement (TKR) and PFJ replacement (PFJR). PFJR has advantages over TKR, including being less invasive, bone preserving, allowing faster recovery and better function and more ‘straight forward’ revision surgery. We aim to compare the clinical results of revised PFJR with primary TKR taking into consideration the survival length of the PFJR. METHODOLOGY. Twenty-five patients (21 female) were retrospectively identified from our arthroplasty database who had undergone revision from PFJR to TKR (2006–2019). These patients were then matched with regards to their age at their primary procedure, sex and total arthroplasty life (primary PFJ survival + Revision PFJ time to follow up) up to point of follow-up with a group of primary TKRs implanted at the same point as the primary PFJR. RESULTS. Mean survival of the PFJs revised were 4.2 years. In the PFJR revision group (mean arthroplasty life 7.8 years) mean Oxford knee score (OKS) at latest follow up was 27.8. In the primary knee group (mean arthroplasty life 7.5 years) mean OKS was 32.4. This difference was not statistically significant. All PFJR revisions were performed using primary prostheses. CONCLUSION. PFJR provides comparable clinical outcome even after revision surgery to TKR as primary TKRs at midterm follow up and should be considered in all patients meeting the selection criteria. Given comparable proms and straight forward revisions, staged arthroplasty to preserve bone-stock is a reasonable choice


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 113 - 122
1 Jan 2021
Kayani B Tahmassebi J Ayuob A Konan S Oussedik S Haddad FS

Aims. The primary aim of this study was to compare the postoperative systemic inflammatory response in conventional jig-based total knee arthroplasty (conventional TKA) versus robotic-arm assisted total knee arthroplasty (robotic TKA). Secondary aims were to compare the macroscopic soft tissue injury, femoral and tibial bone trauma, localized thermal response, and the accuracy of component positioning between the two treatment groups. Methods. This prospective randomized controlled trial included 30 patients with osteoarthritis of the knee undergoing conventional TKA versus robotic TKA. Predefined serum markers of inflammation and localized knee temperature were collected preoperatively and postoperatively at six hours, day 1, day 2, day 7, and day 28 following TKA. Blinded observers used the Macroscopic Soft Tissue Injury (MASTI) classification system to grade intraoperative periarticular soft tissue injury and bone trauma. Plain radiographs were used to assess the accuracy of achieving the planned postioning of the components in both groups. Results. Patients undergoing conventional TKA and robotic TKA had comparable changes in the postoperative systemic inflammatory and localized thermal response at six hours, day 1, day 2, and day 28 after surgery. Robotic TKA had significantly reduced levels of interleukin-6 (p < 0.001), tumour necrosis factor-α (p = 0.021), ESR (p = 0.001), CRP (p = 0.004), lactate dehydrogenase (p = 0.007), and creatine kinase (p = 0.004) at day 7 after surgery compared with conventional TKA. Robotic TKA was associated with significantly improved preservation of the periarticular soft tissue envelope (p < 0.001), and reduced femoral (p = 0.012) and tibial (p = 0.023) bone trauma compared with conventional TKA. Robotic TKA significantly improved the accuracy of achieving the planned limb alignment (p < 0.001), femoral component positioning (p < 0.001), and tibial component positioning (p < 0.001) compared with conventional TKA. Conclusion. Robotic TKA was associated with a transient reduction in the early (day 7) postoperative inflammatory response but there was no difference in the immediate (< 48 hours) or late (day 28) postoperative systemic inflammatory response compared with conventional TKA. Robotic TKA was associated with decreased iatrogenic periarticular soft tissue injury, reduced femoral and tibial bone trauma, and improved accuracy of component positioning compared with conventional TKA. Cite this article: Bone Joint J 2021;103-B(1):113–122


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 680 - 687
1 Jul 2024
Mancino F Fontalis A Grandhi TSP Magan A Plastow R Kayani B Haddad FS

Aims. Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up. Methods. This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36). Results. There were no differences between the two treatment groups with regard to mean change in haemoglobin concentration (p = 0.477), length of stay (LOS, p = 0.172), mean polyethylene thickness (p = 0.065), or postoperative complication rates (p = 0.295). At the most recent follow-up, the primary robotic arm-assisted TKA group had a statistically significantly improved OKS compared with the revision UKA to TKA group (44.6 (SD 2.7) vs 42.3 (SD 2.5); p = 0.004) but there was no difference in the overall ROM (p = 0.056) or FJS between the two treatment groups (86.1 (SD 9.6) vs 84.1 (4.9); p = 0.439). Conclusion. Robotic arm-assisted revision of UKA to TKA was associated with comparable intraoperative blood loss, early postoperative rehabilitation, functional outcomes, and complications to primary robotic TKA at short-term follow-up. Robotic arm-assisted surgery offers a safe and reproducible technique for revising failed UKA to TKA. Cite this article: Bone Joint J 2024;106-B(7):680–687


Aims. Nearly 99,000 total knee arthroplasties (TKAs) are performed in UK annually. Despite plenty of research, the satisfaction rate of this surgery is around 80%. One of the important intraoperative factors affecting the outcome is alignment. The relationship between joint obliquity and functional outcomes is not well understood. Therefore, a study is required to investigate and compare the effects of two types of alignment (mechanical and kinematic) on functional outcomes and range of motion. Methods. The aim of the study is to compare navigated kinematically aligned TKAs (KA TKAs) with navigated mechanically aligned TKA (MA TKA) in terms of function and ROM. We aim to recruit a total of 96 patients in the trial. The patients will be recruited from clinics of various consultants working in the trust after screening them for eligibility criteria and obtaining their informed consent to participate in this study. Randomization will be done prior to surgery by a software. The primary outcome measure will be the Knee injury and Osteoarthritis Outcome Score The secondary outcome measures include Oxford Knee Score, ROM, EuroQol five-dimension questionnaire, EuroQol visual analogue scale, 12-Item Short-Form Health Survey (SF-12), and Forgotten Joint Score. The scores will be calculated preoperatively and then at six weeks, six months, and one year after surgery. The scores will undergo a statistical analysis. Discussion. There is no clear evidence on the best alignment for a knee arthroplasty. This randomized controlled trial will test the null hypothesis that navigated KA TKAs do not perform better than navigated MA TKAs. Cite this article: Bone Jt Open 2021;2(11):945–950


Introduction. The first VRAS TKA was performed in New Zealand in November 2020 using a Patient Specific Balanced Technique whereby VRAS enables very accurate collection of the bony anatomy and soft tissue envelope of the knee to plan and execute the optimal positioning for a balanced TKA. Method. The first 45 VRAS patients with idiopathic osteoarthritis of the knee was compared with 45 sequential patients who underwent the same TKA surgical technique using Brainlab 3 which the author has used exclusively in over 1500 patients. One and two year outcome data will be presented. Results. One year outcome dataVely Brainlab Significance Oxford 43.4 40.5 P=0.01 WOMAC 8.4 14.1P=0.02 Forgotten Joint Score 72.2 58.3 P=0.01 KOOS ADL91.3 85.8 P=0.04 Normal 83.3 74.2P =0.048 Activity Pain 8.6 18.4 P=0.009 ROM 127 124 P=0.01 Patient Satisfaction 98% 95% P=0.62 Operation again 100% 91% P=0.055 The two year data will be available for the ASM Conclusion: The one year outcome data shows a significantly better Oxford, WOMAC, Forgotten Joint score, KOOS ADL, Normal score and ROM scores and the activity pain is less compared to the authors extensive experience with Brainlab 3


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 249 - 255
1 Mar 2024
Inclan PM Brophy RH Saccone NL Ma Y Pham V Yanik EL

Aims. The purpose of this study is to determine an individual’s age-specific prevalence of total knee arthroplasty (TKA) after cruciate ligament surgery, and to identify clinical and genetic risk factors associated with undergoing TKA. Methods. This study was a retrospective case-control study using the UK Biobank to identify individuals reporting a history of cruciate ligament surgery. Data from verbal history and procedural codes recorded through the NHS were used to identify instances of TKA. Patient clinical and genetic data were used to identify risk factors for progression from cruciate ligament surgery to TKA. Individuals without a history of cruciate ligament reconstruction were used for comparison. Results. A total of 2,576 individuals with a history of cruciate ligament surgery were identified, with 290 (11.25%) undergoing TKA. In patients with prior cruciate ligament surgery, prevalence of TKA was 0.75% at age 45 years, 9.10% at age 65 years, and 20.43% at age 80 years. Patients with prior cruciate ligament surgery were 4.6 times more likely to have undergone TKA by age 55 years than individuals without prior cruciate ligament surgery. In the cruciate ligament surgery cohort, BMI > 30 kg/m. 2. (odds ratio (OR) 4.01 (95% confidence interval (CI) 2.74 to 5.87)), a job that always involved heavy manual or physical labour (OR 2.72 (95% CI 1.57 to 4.71)), or a job that always involved walking and standing (OR 2.58 (95% CI 1.58 to 4.20)) were associated with greater TKA odds. No single-nucleotide polymorphism (SNP) was associated with risk of TKA following cruciate ligament surgery. Conclusion. Patients with a history of prior cruciate ligament surgery have substantially higher risk of TKA and undergo arthroplasty at a relatively younger age than individuals without a history of prior cruciate ligament surgery. Physically demanding work and obesity were associated with higher odds of TKA after cruciate ligament surgery, but no SNP was associated with risk of TKA. Cite this article: Bone Joint J 2024;106-B(3):249–255


Bone & Joint Open
Vol. 4, Issue 8 | Pages 621 - 627
22 Aug 2023
Fishley WG Paice S Iqbal H Mowat S Kalson NS Reed M Partington P Petheram TG

Aims. The rate of day-case total knee arthroplasty (TKA) in the UK is currently approximately 0.5%. Reducing length of stay allows orthopaedic providers to improve efficiency, increase operative throughput, and tackle the rising demand for joint arthroplasty surgery and the COVID-19-related backlog. Here, we report safe delivery of day-case TKA in an NHS trust via inpatient wards with no additional resources. Methods. Day-case TKAs, defined as patients discharged on the same calendar day as surgery, were retrospectively reviewed with a minimum follow-up of six months. Analysis of hospital and primary care records was performed to determine readmission and reattendance rates. Telephone interviews were conducted to determine patient satisfaction. Results. Since 2016, 301/7350 TKAs (4.1%) in 290 patients at our institution were discharged on the day of surgery. Mean follow-up was 31.4 months (6.2 to 70.0). In all, 28 patients (9.3%) attended the emergency department or other acute care settings within 90 days of surgery, most often with wound concerns or leg swelling; six patients (2.0%) were readmitted. No patients underwent a subsequent revision procedure, and there were no periprosthetic infections. Two patients (0.7%) underwent secondary patella resurfacing, and one patient underwent arthroscopic arthrolysis after previous manipulation under anaesthetic (MUA). Three patients (1.0%) underwent MUA alone. Primary care consultation records, available for 206 patients, showed 16 patients (7.8%) contacted their general practitioner within two weeks postoperatively; two (1.0%) were referred to secondary care. Overall, 115/121 patients (95%) telephoned stated they would have day-case TKA again. Conclusion. Day-case TKA can be safely delivered in the NHS with no additional resources. We found low incidence of contact with primary and secondary care in the postoperative period, and high patient satisfaction. Cite this article: Bone Jt Open 2023;4(8):621–627


Bone & Joint Open
Vol. 1, Issue 2 | Pages 8 - 12
18 Feb 2020
Bhimani SJ Bhimani R Smith A Eccles C Smith L Malkani A

Aims. Robotic-assisted total knee arthroplasty (RA-TKA) has been introduced to provide accurate bone cuts and help achieve the target knee alignment, along with symmetric gap balancing. The purpose of this study was to determine if any early clinical benefits could be realized following TKA using robotic-assisted technology. Methods. In all, 140 consecutive patients undergoing RA-TKA and 127 consecutive patients undergoing conventional TKA with minimum six-week follow-up were reviewed. Differences in visual analogue scores (VAS) for pain at rest and with activity, postoperative opiate usage, and length of stay (LOS) between the RA-TKA and conventional TKA groups were compared. Results. Patients undergoing RA-TKA had lower average VAS pain scores at rest (p = 0.001) and with activity (p = 0.03) at two weeks following the index procedure. At the six-week interval, the RA-TKA group had lower VAS pain scores with rest (p = 0.03) and with activity (p = 0.02), and required 3.2 mg less morphine equivalents per day relative to the conventional group (p < 0.001). At six weeks, a significantly greater number of patients in the RA-TKA group were free of opioid use compared to the conventional TKA group; 70.7% vs 57.0% (p = 0.02). Patients in the RA-TKA group had a shorter LOS; 1.9 days versus 2.3 days (p < 0.001), and also had a greater percentage of patient discharged on postoperative day one; 41.3% vs 20.5% (p < 0.001). Conclusion. Patients undergoing RA-TKA had lower pain levels at both rest and with activity, required less opioid medication, and had a shorter LOS


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 760 - 763
1 Aug 2024
Mancino F Fontalis A Haddad FS


Bone & Joint Open
Vol. 3, Issue 8 | Pages 656 - 665
23 Aug 2022
Tran T McEwen P Peng Y Trivett A Steele R Donnelly W Clark G

Aims. The mid-term results of kinematic alignment (KA) for total knee arthroplasty (TKA) using image derived instrumentation (IDI) have not been reported in detail, and questions remain regarding ligamentous stability and revisions. This paper aims to address the following: 1) what is the distribution of alignment of KA TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does extending limb alignment lead to changes in soft-tissue laxity; and 4) what is the five-year survivorship and outcomes of KA TKA using IDI?. Methods. A prospective, multicentre, trial enrolled 100 patients undergoing KA TKA using IDI, with follow-up to five years. Alignment measures were conducted pre- and postoperatively to assess constitutional alignment and final implant position. Patient-reported outcome measures (PROMs) of pain and function were also included. The Australian Orthopaedic Association National Joint Arthroplasty Registry was used to assess survivorship. Results. The postoperative HKA distribution varied from 9° varus to 11° valgus. All PROMs showed statistical improvements at one year (p < 0.001), with further improvements at five years for Knee Osteoarthritis Outcome Score symptoms (p = 0.041) and Forgotten Joint Score (p = 0.011). Correlation analysis showed no difference (p = 0.610) between the hip-knee-ankle and joint line congruence angle at one and five years. Sub-group analysis showed no difference in PROMs for patients placed within 3° of neutral compared to those placed > 3°. There were no revisions for tibial loosening; however, there were reports of a higher incidence of poor patella tracking and patellofemoral stiffness. Conclusion. PROMs were not impacted by postoperative alignment category. Ligamentous stability was maintained at five years with joint line obliquity. There were no revisions for tibial loosening despite a significant portion of tibiae placed in varus; however, KA executed with IDI resulted in a higher than anticipated rate of patella complications. Cite this article: Bone Jt Open 2022;3(8):656–665


Bone & Joint Open
Vol. 4, Issue 11 | Pages 899 - 905
24 Nov 2023
Orfanos G Nantha Kumar N Redfern D Burston B Banerjee R Thomas G

Aims

We aim to evaluate the usefulness of postoperative blood tests by investigating the incidence of abnormal results following total joint replacement (TJR), as well as identifying preoperative risk factors for abnormal blood test results postoperatively, especially pertaining to anaemia and acute kidney injury (AKI).

Methods

This is a retrospective cohort study of patients who had elective TJR between January and December 2019 at a tertiary centre. Data gathered included age at time of surgery, sex, BMI, American Society of Anesthesiologists (ASA) grade, preoperative and postoperative laboratory test results, haemoglobin (Hgb), white blood count (WBC), haematocrit (Hct), platelets (Plts), sodium (Na+), potassium (K+), creatinine (Cr), estimated glomerular filtration rate (eGFR), and Ferritin (ug/l). Abnormal blood tests, AKI, electrolyte imbalance, anaemia, transfusion, reoperation, and readmission within one year were reported.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 52 - 52
1 Dec 2022
Hawker G Bohm E Dunbar M Jones CA Ravi B Noseworthy T Woodhouse L Faris P Dick DA Powell J Paul P Marshall D
Full Access

With the rising rates, and associated costs, of total knee arthroplasty (TKA), enhanced clarity regarding patient appropriateness for TKA is warranted. Towards addressing this gap, we elucidated in qualitative research that surgeons and osteoarthritis (OA) patients considered TKA need, readiness/willingness, health status, and expectations of TKA most important in determining patient appropriateness for TKA. The current study evaluated the predictive validity of pre-TKA measures of these appropriateness domains for attainment of a good TKA outcome. This prospective cohort study recruited knee OA patients aged 30+ years referred for TKA at two hip/knee surgery centers in Alberta, Canada. Those receiving primary, unilateral TKA completed questionnaires pre-TKA assessing TKA need (WOMAC-pain, ICOAP-pain, NRS-pain, KOOS-physical function, Perceived Arthritis Coping Efficacy, prior OA treatment), TKA readiness/willingness (Patient Acceptable Symptom State (PASS), willingness to undergo TKA), health status (PHQ-8, BMI, MSK and non-MSK comorbidities), TKA expectations (HSS KR Expectations survey items) and contextual factors (e.g., age, gender, employment status). One-year post-TKA, we assessed for a ‘good outcome’ (yes/no), defined as improved knee symptoms (OARSI-OMERACT responder criteria) AND overall satisfaction with TKA results. Multiple logistic regression, stepwise variable selection, and best possible subsets regression was used to identify the model with the smallest number of independent variables and greatest discriminant validity for our outcome. Receiver Operating Characteristic (ROC) curves were generated to compare the discriminative ability of each appropriateness domain based on the ‘area under the ROC curve’ (AUC). Multivariable robust Poisson regression was used to assess the relationship of the variables to achievement of a good outcome. f 1,275 TKA recipients, 1,053 (82.6%) had complete data for analyses (mean age 66.9 years [SD 8.8]; 58.6% female). Mean WOMAC pain and KOOS-PS scores were 11.5/20 (SD 3.5) and 52.8/100 (SD 17.1), respectively. 78.1% (95% CI 75.4–80.5%) achieved a good outcome. Stepwise variable selection identified optimal discrimination was achieved with 13 variables. The three best 13-variable models included measures of TKA need (WOMAC pain, KOOS-PS), readiness/willingness (PASS, TKA willingness), health status (PHQ-8, troublesome hips, contralateral knee, low back), TKA expectations (the importance of improved psychological well-being, ability to go up stairs, kneel, and participate in recreational activities as TKA outcomes), and patient age. Model discrimination was fair for TKA need (AUC 0.68, 95% CI 0.63-0.72), TKA readiness/willingness (AUC 0.61, 95% CI 0.57-0.65), health status (AUC 0.59, 95% CI 0.54-0.63) and TKA expectations (AUC 0.58, 95% CI 0.54-0.62), but the model with all appropriateness variables had good discrimination (AUC 0.72, 95% CI 0.685-0.76). The likelihood of achieving a good outcome was significantly higher for those with greater knee pain, disability, unacceptable knee symptoms, definite willingness to undergo TKA, less depression who considered improved ability to perform recreational activities or climb stairs ‘very important’ TKA outcomes, and lower in those who considered it important that TKA improve psychological wellbeing or ability to kneel. Beyond surgical need (OA symptoms) and health status, assessment of patients’ readiness and willingness to undergo, and their expectations for, TKA, should be incorporated into assessment of patient appropriateness for surgery


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 37 - 37
7 Aug 2023
Mudiganty S Jayadev C Carrington R Miles J Donaldson J Mcculloch R
Full Access

Abstract. Introduction. Total knee replacement (TKR) in patients with skeletal dysplasia is technically challenging surgery due to deformity, joint contracture, and associated co-morbidities. The aim of this study is to follow up patients with skeletal dysplasia following a TKR. Methodology. We retrospectively reviewed 22 patients with skeletal dysplasia who underwent 31 TKRs at our institution between 2006 and 2022. Clinical notes, operative records and radiographic data were reviewed. Results. Achondroplasia was the most common skeletal dysplasia (8), followed by Chondrodysplasia punctata (7) and Spondyloepiphyseal dysplasia (5). There were fourteen men and eight women with mean age of 51 years (28 to 73). The average height of patients was 1.4 metres (1.16–1.75) and the mean weight was 64.8 Kg (34.3–100). The mean follow up duration was 68.32 months (1–161). Three patients died during follow up. Custom implants were required in twelve patients (38.71%). Custom jigs were utilised in six patients and two patients underwent robotic assisted surgery. Hinged TKR was used in seventeen patients (54.84%), posterior stabilised TKR in nine patients (29.03%), and cruciate retaining TKR in five patients (16.13%). One patient underwent a patella resurfacing for persistent anterior knee pain and another had an intra-operative medial tibial plateau fracture which was managed with fixation. No revisions occurred during the follow up period. Conclusion. Despite the technical challenges and complexity of TKR within this unique patient group, we demonstrate good implant survivorship during the study period. Cross sectional imaging is recommended preoperatively for precise planning and templating


Bone & Joint Open
Vol. 3, Issue 5 | Pages 383 - 389
1 May 2022
Motesharei A Batailler C De Massari D Vincent G Chen AF Lustig S

Aims. No predictive model has been published to forecast operating time for total knee arthroplasty (TKA). The aims of this study were to design and validate a predictive model to estimate operating time for robotic-assisted TKA based on demographic data, and evaluate the added predictive power of CT scan-based predictors and their impact on the accuracy of the predictive model. Methods. A retrospective study was conducted on 1,061 TKAs performed from January 2016 to December 2019 with an image-based robotic-assisted system. Demographic data included age, sex, height, and weight. The femoral and tibial mechanical axis and the osteophyte volume were calculated from CT scans. These inputs were used to develop a predictive model aimed to predict operating time based on demographic data only, and demographic and 3D patient anatomy data. Results. The key factors for predicting operating time were the surgeon and patient weight, followed by 12 anatomical parameters derived from CT scans. The predictive model based only on demographic data showed that 90% of predictions were within 15 minutes of actual operating time, with 73% within ten minutes. The predictive model including demographic data and CT scans showed that 94% of predictions were within 15 minutes of actual operating time and 88% within ten minutes. Conclusion. The primary factors for predicting robotic-assisted TKA operating time were surgeon, patient weight, and osteophyte volume. This study demonstrates that incorporating 3D patient-specific data can improve operating time predictions models, which may lead to improved operating room planning and efficiency. Cite this article: Bone Jt Open 2022;3(5):383–389