Advertisement for orthosearch.org.uk
Results 1 - 50 of 222
Results per page:

Aims

The primary aim of this study was to report the radiological outcomes of patients with a dorsally displaced distal radius fracture who were randomized to a moulded cast or surgical fixation with wires following manipulation and closed reduction of their fracture. The secondary aim was to correlate radiological outcomes with patient-reported outcome measures (PROMs) in the year following injury.

Methods

Participants were recruited as part of DRAFFT2, a UK multicentre clinical trial. Participants were aged 16 years or over with a dorsally displaced distal radius fracture, and were eligible for the trial if they needed a manipulation of their fracture, as recommended by their treating surgeon. Participants were randomly allocated on a 1:1 ratio to moulded cast or Kirschner wires after manipulation of the fracture in the operating theatre. Standard posteroanterior and lateral radiographs were performed in the radiology department of participating centres at the time of the patient’s initial assessment in the emergency department and six weeks postoperatively. Intraoperative fluoroscopic images taken at the time of fracture reduction were also assessed.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 139 - 139
1 Feb 2003
O’Shea K McCarthy T Moore D Dowling F Fogarty E
Full Access

Neonatal septic arthritis is a true orthopaedic emergency posing significant threat to life and limb. Objective: To examine the clinical presentation, diagnosis, treatment and outcome of children presenting with septic arthritis in the neonatal period. Design: Retrospective review of clinical notes and radiographs of children presenting over a 20 year period (1977–97). Subjects: 34 patients with septic arthritis in a total of 36 joints. Outcome measures: Clinical outcome was classified as satisfactory or unsatisfactory as per Morrey et al. Radiological outcome was graded I–IV as per Choi et al. Joint instability, destruction, limb length discrepancy and angular deformity were assessed. Results: The hip joint was affected in 24 of the 34 cases. Pseudoparalysis was the most reliable clinical finding occurring in 29 out of 34 cases. Staph Aureus was isolated as the infecting pathogen in 22/34 patients. Sequelae occurred in 16 hips and 1 knee. Poor prognostic indicators were delayed diagnosis (p< 0.05) and the hip as site of infection (p< 0.01). Clinical outcome was unsatisfactory in 15 patients and satisfactory in 17 patients. Radiological outcome was Choi I or IIA (good) in 12 hips and Choi II to IV in 13 hips (poor). Multiple further reconstructive procedures were required in 15 cases. Conclusions: Despite optimum treatment, neonatal septic arthritis results in significant long-term morbidity for a high proportion of cases


Bone & Joint Open
Vol. 2, Issue 3 | Pages 191 - 197
1 Mar 2021
Kazarian GS Barrack RL Barrack TN Lawrie CM Nunley RM

Aims

The purpose of this study was to compare the radiological outcomes of manual versus robotic-assisted medial unicompartmental knee arthroplasty (UKA).

Methods

Postoperative radiological outcomes from 86 consecutive robotic-assisted UKAs (RAUKA group) from a single academic centre were retrospectively reviewed and compared to 253 manual UKAs (MUKA group) drawn from a prior study at our institution. Femoral coronal and sagittal angles (FCA, FSA), tibial coronal and sagittal angles (TCA, TSA), and implant overhang were radiologically measured to identify outliers.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 269 - 269
1 Jul 2008
LECUIRE F JALOUL K RUBINI J BASSO M BENAREAU I
Full Access

Purpose of the study: The Alpina unicompartimen-tal knee prosthesis (Biomet) is an anatomic prosthesis inserted with a femoral cut, a tibial base plate made of titanium and a flat modular polyethylene insert. Cemented and non-cemented versions are available with hydroxyapatite ceramic (HAC) coating. Material and methods: We retrospectively reviewed the radiological outcome at more than five years (fie to eight years follow-up) in a consecutive series of patients who had an Alpina HAC prosthesis with tibial fixation completed with a titanium screw. Clinical and radiological findings were recorded. Radiologically: pre- and postoperative angles, implant position, reliability of the instrument set. At last follow-up, we studied the presence of lucent lines, polyethylene wear easily measured on the flat insert, and bone remodeling around the tibial fixation screw. Results: At last follow-up (5 to 8 years), three patients were lost to follow-up and three had died. Radiological outcome was thus assessed for 44 implants (41 medial and 3 lateral). One patient required an early total knee prosthesis (diagnostic error). Three patients underwent revision at 5–7 years (for rupture of the polyethylene insert in two very active patients, and for significant polyethylene wear in the third). Two had a revision procedure for a partial knee prosthesis and the third for a total knee prosthesis. For the 40 other patients, the following observations were made: partial lucent line along the tibial polyethylene plate with no functional impact (n=1), polyethylene wear visible but measuring less than 1 mm (n=12), remodeling around the tibial fixation screw probably corresponding to a granuloma but not threatening the implant (n=10). Discussion: The clinical results of partial knee prostheses are well known. Mid-term radiographic results of non-cemented unicompartmental prostheses with a flat tibial plateau producing a minimal contact surface has shown: good reliability of the instrument set, excellent bony integration of the HAC-coated implants, but measurable polyethylene wear on more than one quarter of the prostheses, with two ruptures of the polyethylene insert at 5 and 6 years. Conclusion: A study currently under way will examine finished pieces on a simulator to study wear and failure as a function of several parameters: polyethylene thickness, lateral restraint with a metal rim, presence of a basal stem fixing the polyethylene on the metal base, importance of the femur-polyethylene surface contact


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 10 - 10
7 Nov 2023
Arnolds D Marie-Hardy L Dunn R
Full Access

Adolescent idiopathic scoliosis is a three-dimensional deformity of the spine, affecting 1–3% of the population.

Most cases are treated conservatively. Curves exceeding 45° in the thoracic spine and 40° in the lumbar spine may require correction and fusion surgery, to limit the progression of the curve and prevent restrictive pulmonary insufficiency (curves above 70°). When fusion is required, it may be performed either by posterior or anterior approaches. Posterior is useful for thoracic (Lenke I) curves, notably to correct the thoracic hypokyphosis frequently observed in AIS. Anterior approaches by thoraco-lombotomies allow an effective correction of thoraco-lumbar and lumbar curves (Lenke V and VI), with fewer levels fused than with posterior approaches. However, the approach requires diaphragm splitting and one may be concerned about the long-term pulmonary consequences. The literature provides conflicting insight regarding the consequences of the approach in anterior scoliosis correction, the interpretation of the results being difficult knowing that the correction of the scoliosis itself may improve pulmonary function.

This is a retrospective observational study done at a Tertiary Institution. The HRQOL scores have been collected as a prospective cohort. Clinical and radiographic data was collected from patients charts and analysed by two senior surgeons

A cohort of 64 patients were operated in the given time period. 50 patients met the inclusion criteria. No major complications were reported. The Union rate was 100% and no post operative complications were noted. Pre and post SRS scores improved in all patients.

The Anterior approach for Lenke V AIS gives great surgical exposure and allows for excellent correction of Cobb angle with minimal risk to the patient.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 516 - 516
1 Oct 2010
Grabmeier G Berger C Engel A Newrkla S Seidl S
Full Access

Background: Patients with femoral head osteonecrosis usually tend to be younger and more active when compared with osteoarthritis patients. Second generation metal-on-metal THA was reintroduced to reduce poly-ethylene-induced wear debris, and therefore increase longevity of implants. The aim of this retrospective study was to compare full blood cobalt-chrome levels, patient activity, clinical/radiological outcome and implant survival in patients with osteonecrosis and osteoarthritis after a minimum follow up of 12 years. Methods: Full blood cobalt-chrome levels of a consecutive series of 125 patients, consisting of 40 patients (38 male, 2 female, average age 35 years, range 28 to 46 years) with osteonecrosis (ON group) and 85 patients (60 male, 25 female, average age 58 years, range 52 to 68 years) with osteoarthritis (OA group) as primary diagnosis were retrospectively compared. Patient activity level was assessed using UCLA Score and clinical outcome was evaluated using HHS. Radiological outcome and implant survival (Kaplan Meyer analysis) was determined in both groups. Results: Patients with osteonecrosis of the femoral head showed significant higher UCLA scores when compared to OA group (4 versus 7) (p < 0.05). Despite this higher patient activity no significant difference was found between cobalt-chrome full blood levels (2.1/1.6 μg/l, ON group, 1.9/1.8 μg/l OA group, respectively) (p > 0.05). No positive correlation between patient activity, acetabular cup abduction angle and cobalt-chrome levels was found (r. 2. < 0.01). Clinical and radiological outcome were equal in both groups. Harris hip score was 91 points in the OA and 92 in the ON group (p > 0.05). Average cup inclination angle was 47° (range 32° to 55°) and 44° (range 30° to 56°) respectively (p > 0.05). Implant survival at 12 years follow up was 96% in the OA and 97% in the ON group. Conclusion: After a minimum follow up of 12 years, we could not find increased metal levels in osteonecrosis patients when compared to the osteoartrithis group. Regarding our clinical and radiological outcome we cannot confirm previously published reports showing suboptimal results of THA in patients with osteonecrosis. Implant survival data did not differ among both group. Metal on metal THA seems to be an effective and safe treatment option for these patients


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 66 - 73
1 May 2024
Chaudhry F Daud A Greenberg A Braunstein D Safir OA Gross AE Kuzyk PR

Aims

Pelvic discontinuity is a challenging acetabular defect without a consensus on surgical management. Cup-cage reconstruction is an increasingly used treatment strategy. The present study evaluated implant survival, clinical and radiological outcomes, and complications associated with the cup-cage construct.

Methods

We included 53 cup-cage construct (51 patients) implants used for hip revision procedures for pelvic discontinuity between January 2003 and January 2022 in this retrospective review. Mean age at surgery was 71.8 years (50.0 to 92.0; SD 10.3), 43/53 (81.1%) were female, and mean follow-up was 6.4 years (0.02 to 20.0; SD 4.6). Patients were implanted with a Trabecular Metal Revision Shell with either a ZCA cage (n = 12) or a TMARS cage (n = 40, all Zimmer Biomet). Pelvic discontinuity was diagnosed on preoperative radiographs and/or intraoperatively. Kaplan-Meier survival analysis was performed, with failure defined as revision of the cup-cage reconstruction.


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims

This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA).

Methods

From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery.


Bone & Joint Open
Vol. 5, Issue 5 | Pages 374 - 384
1 May 2024
Bensa A Sangiorgio A Deabate L Illuminati A Pompa B Filardo G

Aims

Robotic-assisted unicompartmental knee arthroplasty (R-UKA) has been proposed as an approach to improve the results of the conventional manual UKA (C-UKA). The aim of this meta-analysis was to analyze the studies comparing R-UKA and C-UKA in terms of clinical outcomes, radiological results, operating time, complications, and revisions.

Methods

The literature search was conducted on three databases (PubMed, Cochrane, and Web of Science) on 20 February 2024 according to the guidelines for Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA). Inclusion criteria were comparative studies, written in the English language, with no time limitations, on the comparison of R-UKA and C-UKA. The quality of each article was assessed using the Downs and Black Checklist for Measuring Quality.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 668 - 678
1 Jun 2023
Friedman RJ Boettcher ML Grey S Flurin P Wright TW Zuckerman JD Eichinger JK Roche C

Aims

The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system.

Methods

We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217).


Bone & Joint Open
Vol. 5, Issue 5 | Pages 411 - 418
20 May 2024
Schneider P Bajammal S Leighton R Witges K Rondeau K Duffy P

Aims

Isolated fractures of the ulnar diaphysis are uncommon, occurring at a rate of 0.02 to 0.04 per 1,000 cases. Despite their infrequency, these fractures commonly give rise to complications, such as nonunion, limited forearm pronation and supination, restricted elbow range of motion, radioulnar synostosis, and prolonged pain. Treatment options for this injury remain a topic of debate, with limited research available and no consensus on the optimal approach. Therefore, this trial aims to compare clinical, radiological, and functional outcomes of two treatment methods: open reduction and internal fixation (ORIF) versus nonoperative treatment in patients with isolated ulnar diaphyseal fractures.

Methods

This will be a multicentre, open-label, parallel randomized clinical trial (under National Clinical Trial number NCT01123447), accompanied by a parallel prospective cohort group for patients who meet the inclusion criteria, but decline randomization. Eligible patients will be randomized to one of the two treatment groups: 1) nonoperative treatment with closed reduction and below-elbow casting; or 2) surgical treatment with ORIF utilizing a limited contact dynamic compression plate and screw construct. The primary outcome measured will be the Disabilities of the Arm, Shoulder and Hand questionnaire score at 12 months post-injury. Additionally, functional outcomes will be assessed using the 36-Item Short Form Health Survey and pain visual analogue scale, allowing for a comparison of outcomes between groups. Secondary outcome measures will encompass clinical outcomes such as range of motion and grip strength, radiological parameters including time to union, as well as economic outcomes assessed from enrolment to 12 months post-injury.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 50 - 50
1 Jan 2016
Moo IH Pagkaliwagan EH Poon KB
Full Access

Interest in minimal-incision total knee arthroplasty (TKA) has increased in recent years. The advantages of minimally invasive techniques (MIS) used for TKA are faster functional recovery, shorter hospital stay and better early knee range of motion. It is known that the long-term outcome after TKA is related to component position and ligament balance. The smaller incision in MIS might be associated with increased risk of malalignment of components due to limited visualisation. Malalignment of implants in TKA has been associated with implant failure and poor long-term functional results. There is a lack of evidence in the literature that MIS can achieve the same results as the standard TKR approach in terms of component alignment precision. Seventy patients scheduled for a primary TKA were prospectively evaluated postoperatively with coronal and sagittal radiographic long limb films. Mini-midvastus approach was used for all TKA. There were no complications and the radiographic evaluation found no implant or limb malalignment, or signs of early loosening. We did not observe wound healing problems, fractures or implant notching. The mini-midvastus approach can reproduces the same accuracy in component positioning as the standard medial parapatellar approach. A precise operation technique and adequate visualisation of anatomical landmarks during implantation are the key points of success in mini-midvastus approach.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 257 - 264
1 Feb 2022
Tahir M Mehta D Sandhu C Jones M Gardner A Mehta JS

Aims

The aim of this study was to compare the clinical and radiological outcomes of patients with early-onset scoliosis (EOS), who had undergone spinal fusion after distraction-based spinal growth modulation using either traditional growing rods (TGRs) or magnetically controlled growing rods (MCGRs).

Methods

We undertook a retrospective review of skeletally mature patients who had undergone fusion for an EOS, which had been previously treated using either TGRs or MCGRs. Measured outcomes included sequential coronal T1 to S1 height and major curve (Cobb) angle on plain radiographs and any complications requiring unplanned surgery before final fusion.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 88 - 88
1 Dec 2015
Weerwag L Schreurs B Rijnen W
Full Access

Prosthetic joint infection (PJI) is a severe complication of prosthetic joint implantation, with an estimated incidence of 2.18%. Most frequently used treatment strategy for PJI is a two-stage revision procedure. However there are specific patients with a new or persisting infection after primary or revision surgery where further surgical treatment is not attractive. This may be because of medical or local surgical conditions, or patient's refusal to undergo (further) surgical therapy. For these patients suppressive antibiotic therapy (SAT) may be an alternative treatment.

The aim of this study is to describe the clinical and radiological outcome of patients with a PJI of a hip arthroplasty, treated with SAT.

Twenty-four patients with a hip arthroplasty treated with suppressive antibiotic therapy for PJI between January 1, 2008 and December 31, 2013 were included. All patients had a proven prosthetic joint infection, either by ≥2 intraoperative cultures or joint aspiration. SAT was defined as treatment with antibiotic therapy for more than three months. Most used antibiotics were doxycycline in 15 patients and cotrimoxazole in six patients.

Patients were supposed to have a successful outcome when their prosthesis remained in situ and they had no relapse or new infection.

Suppressive antibiotic therapy was considered successful in 15 (62.5%) patients with a mean follow-up of 20.6 months. Two patients (8.3%) had to stop the antibiotic therapy due to adverse effects.

The mean duration of the SAT was 20.4 months (range 0.92–92.65 months).

Mean modified Oxford hip score of the successfully treated patients at the latest follow up was 35 (range 16–49) and mean Harris hip score 71 (range 40–93). The mean visual analogue scale (VAS) was 16 (range 0–70) in rest, 32 (range 0–85) during exercise and 65 (range 10–100) for satisfaction.

Of the 9 patients with an unsuccessful outcome, there was a radiological loosening of the cup in 4 patients. In the group of 15 patients that were considered successful, 2 patients had a radiological loosening of the cup and one patient loosening of the stem.

Suppressive antibiotic therapy can be an attractive alternative treatment in selected patients with a prosthetic joint infection of a hip arthroplasty who cannot or will not undergo (further) surgical therapy.

Further research with a larger number of patients is required. Also the optimal dosage and duration of suppressive antibiotic therapy and possible resistance to the antibiotic therapy is unknown.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1189 - 1195
1 Nov 2023
Kim JS Kim SH Kim SC Park JH Kim HG Lee SM Yoo JC

Aims

The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes.

Methods

This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group).


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 593 - 593
1 Oct 2010
Dornacher D Nelitz M Reichel H
Full Access

Reduction therapy in developmental dysplasia of the hip (DDH) is initialized in the newborn period. Harness treatment is continued until normal ultrasound-values are reached. Above the age of one year the assessment of DDH relies mainly on interpretation of plain radiographs of the pelvis. In order to rule out residual dysplasia after ultrasound controlled treatment radiological control is advised to the time children start walking. The purpose of this study is to evaluate the early radiological outcome after ultrasound controlled treatment of DDH and to examine whether there is a correlation between the initial severitiy of DDH, measured by ultrasound, and the severity of residual DDH on the radiograph at the time of the first follow-up.

A. p. pelvic radiographs of 90 children (72 girls, 18 boys, 180 hips) with DDH (29 unilateral, 61 bilateral) were reviewed retrospectively. To the beginning of the ultrasound surveilled therapy (mean age 7,2 weeks) the morphologic findings were staged according to the Graf classification. Ultrasound surveilled abduction treatment was continued until normal ultrasound findings were reached. To the time children started walking (mean age 14,8 months) an a. p. radiograph of the pelvis was performed. The acetabular index (AI) was measured and classified according to the normal values of the hip joint described by Tönnis. The initial ultrasound findings expressed by the Graf classification were compared with the AI in the radiographic follow-up and Tönnis’ normal values.

To simplify matters the 180 Graf-classified hips were distributed into 4 categories: Graf Ia/b=category 1, Graf IIa-D=category 2, Graf IIIa/b=category 3, Graf IV=category 4. The initially normal contralateral hips in ultrasound (n=29, category 1) presented in 37,9% a normal AI, in 41,4% with a mild dysplasia (between 1SD and 2SD) and in 20,7% with a severe dysplasia (beyond 2SD). The Graf type IIa-D hips (n=81, category 2) presented in 37% a normal AI, 32,1% showed a mild dysplasia and 30,9% a severe dysplasia. The Graf type III a/b hips (n=60, category 3) showed 35%, 30% and 35%, Graf type IV hips (n=10, category 4) 60%, 30% and 10%, respectively.

The mean AI in all four categories differed only marginally.

In our setting of patients different conclusions can be drawn:

Even after successful ultrasound guided therapy with a sonographically normal hip at the time bracing is finished there is a risk for residual dysplasia. Therefore radiological follow-up of every once treated hip is necessary.

To reduce the number of radiographs the time for the first radiographic follow up may be delayed to the age of two. We only see a minimal risk to miss a dislocated hip in time. In very rare cases the indication for an acetabuloplasty is generally seen before the age of two, in our patient population we saw no immediate indication for surgery.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 14 - 14
1 Mar 2012
Zhao G Yamamoto T Ikemura S Motomura G Nakashima Y Mawatari T Iwamoto Y
Full Access

Introduction

Transtrochanteric curved varus osteotomy is one of the effective joint-preserving operations for osteonecrosis (ON) of the femoral head. We correlated various factors with the radiological outcome of this procedure.

Methods

We reviewed 74 hips in 63 patients who had a minimum follow-up of 5 years after transtrochanteric curved varus osteotomy for the treatment of ON. There were 28 men and 35 women who had a mean age of 33 years (range, 15 to 68 years) at the time of surgery. Clinical assessment was made based on the Harris hip score (HHS). Radiographically, we investigated various factors; affected lesion, stage and type (localization of the necrotic lesion) of ON, varus degree, post-operative intact ratio, progression of collapse, and joint-space narrowing. On the basis of postoperative radiographs, the hips were divided into 2 groups (Group I: either the progression of collapse or joint-space narrowing, Group II: neither progression of collapse or joint-space narrowing). The related factors with radiological outcome were analyzed by using multivariate analysis (Stepwise discriminant analysis).


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 146 - 146
1 Apr 2005
McAllen C Eyres K
Full Access

Study Aims The purpose of this study is to determine whether the cement mantle produced when a suction cement technique is used leads improved radiological results in the medium term.

Methods 74 patients who had a cemented total knee replacement were prospectively studied. In 51 patients the cement was applied in a standard fashion. In 23 patients an intraosseous cannula was used to apply suction within the bone to improve cement penetration. The cannula was inserted into the medial femoral condyle and the medial tibial plateau prior to the bone preparation to vent both bones. Suction is applied to help dry the cancellous surface and draw the cement into the bone.

The radiological appearance of the tibial components were prospectively examined to for the appearance of bone lysis.

Conclusion This study shows that this technique produces superior radiological appearances in the medium term, which may lead to longer implant survival.

A previously published study has shown that if total knee replacement is performed without a tourniquet but using the suction cement technique an excellent cement mantle can reliably be produced.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 53 - 53
1 Feb 2017
Kawamoto T Iida S Suzuki C
Full Access

Background

Variability in component alignment continues to be a major in total knee arthroplasty(TKA). In the long term, coronal plane malalignment has been associated with an increased risk of loosening, insatability, and wear. Recently portable navigation system(PNS) in TKA have been introduced. The goal of PNS are to improve the accuracy of post operative alignment and eliminate outlier cases. The aim of this study is to evaluate clinical results and quantify the coronal plane alignment between a group of patients who underwent TKA using PNS versus CT-free large-console navigation system.

Patients and Method

An unselected consecutive series of ninety-four patients undergoing primary TKA using the cruciate retaining cemented total knee system between April 2012 and August 2015 were studied. Patients were included only if they were deemed to be candidates for a Cruciate retaining TKA. Patients were excluded if they had a flexion contracture greater than 40°, or severe valgus or varus deformity. Forty eight knees was operated a TKA with CT-free large-console navigation system(The OrthoPilot system; Aesculap, Tuttlingen, Germany). Subsequently forty six knees was received a TKA using portable navigation system (KneeAlign2TM). Postoperatively standing AP hip-to-ankle radiographs were obtained, from which the lower extremity mechanical axis, component angle were measured. The alignment goals were a neutral mechanical axis defined as a hip-to-ankle angle of 0°with the femoral and tibial components aligned perpendicular to the mechanical axis. The total operating time were quantified utilising an operating room database. The total operating time between TKAs performed with CT-free navigation system and those performed with portable navigation system was compared in each group. All patients postoperatively was evaluated of clinical results the Japan Orthopedics Association(JOA) Knee scores.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 81 - 81
1 Jan 2004
Moran M Soon YL Walmsley P Brenkel IJ
Full Access

Introduction: There is little published on the outcome of orthopaedic surgery performed by surgeons in training. The individual results of orthopaedic units and consultants are coming under increasing scrutiny. There may be concerns that trainee performed THR will negatively impact on these figures. This study compares the outcome of THR’s performed by consultants and supervised trainees.

Methods: Data was prospectively collected on 139 THR’s carried out by supervised specialist registrars (years 1 to 4) and 397 THR’s carried out by consultants. The Harris Hip Score (HHS) was used as the primary outcome measure and scores were taken at 7days pre-operatively, 6 and 18 months post-operatively. In addition data on co-morbidity, blood loss, transfusion requirements, re-operation, dislocation and death were recorded. Radiographs of 110 trainee and 110 consultant performed THR’s were compared at 6 months. Acetabular anteversion and abduction and femoral orientation were assessed on lateral and AP films. Cementation was judged using methods described by Hodgkinson and Barrack.

Results: Blood loss, transfusion requirement, dislocation, revision, deep infection and the HHS at 6 and 18 months showed no statistically significant difference between trainee and consultant (all p< 0.05). Component orientation and cementation quality again showed no significant difference (p< 0.05).

Discussion: This paper reveals no difference in the short term results of THR performed by consultants and supervised trainees. Our results show that quality can be maintained whilst training juniors to operate.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 360 - 365
1 Feb 2021
Mahendraraj KA Shields MV Grubhofer F Golenbock SW Jawa A

Aims

Existing literature indicates that inferiorly inclined glenoid baseplates following reverse total shoulder arthroplasty (RSA) produce better outcomes compared to superiorly inclined baseplates. We aim to compare clinical outcomes for RSAs with superiorly and neutrally/inferiorly inclined lateralized glenospheres.

Methods

We retrospectively reviewed 154 consecutive patients undergoing RSA between July 2015 and July 2017 by one single-fellowship trained surgeon (AJ). Two raters (KAM and MVS) independently measured glenoid inclination in preoperative and minimum two year follow-up radiographs (anteroposterior/Grashey) using the RSA angle. Inclination was then compared to patient-reported outcomes, range of motion (ROM), and independently assessed degree of scapular notching and staging of heterotopic ossification at two year follow-up.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 390 - 390
1 Jul 2011
Ball S Windley J Harnett P Nathwani D
Full Access

Computer navigation has the potential to revolutionise orthopaedic surgery. It is widely accepted that component malalignment and malrotation leads to early failure in knee arthroplasty. We aimed to assess the use and reliability of computer navigation in both total (TKR) and unicompartmental (UKR) knee replacement surgery.

We analysed 40 consecutive UKRs and 40 consecutive TKRs. All procedures were carried out with the Brain-LAB navigation system and all were carried out by one consultant orthopaedic surgeon. Preoperative aim was neutral tibial cuts with 3 degrees posterior slope. Coronal and sagittal alignment of tibial components were measured on postoperative radiographs. Patients were also scored clinically with regards to function and pain.

In the TKR group, mean tibial coronal alignment was 0° (range 1 to −2.) Mean sagittal alignment was 2° posterior slope (range 0 to 4.) In the UKR group, mean tibial coronal alignment was 0.55° (range 0 to −3.) Mean sagittal alignment was 2.1° posterior slope (range 0 to 4°.) Clinical outcome scores were very satisfactory for the majority of patients, with far superior functional scores in the UKR group.

Our results demonstrate very accurate placement of the prosthesis in both the TKR and UKR group with computer navigation. There is a very narrow range with no outliers, (all within +/−3 degrees of desired alignment.) Functional outcome scores are good. We advocate the use of computer navigation in unicompartmental as well as total knee replacment surgery, in order to minimise early failures.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 123 - 123
1 May 2011
Salvo D Holzer N Lübbeke A Hoffmeyer P Assal M
Full Access

Introduction: An ankle fracture represents the most frequent osseous injury in both the elderly and non-elderly population. To date, only a limited number of retrospective studies have addressed medium-term outcome following ankle Open Reduction and Internal Fixation (ORIF). The purpose of this study was to assess residual pain and functional outcome 10 to 20 years after operative treatment of ankle fractures and to evaluate the incidence of symptomatic and radiographic ankle osteoarthritis (OA).

Methods: We designed a retrospective study including all consecutive patients who underwent ankle ORIF between January 1988 and December 1997 in a University Hospital setting. Pilon and talus fracture as well as pediatric patients were excluded. Patients were seen by two senior residents 10–20 years after their index surgery. Residual pain was measured using the Visual Analog pain Scale. Function and general health status were assessed using the Olerud and Molander Ankle Score, the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score and the 12-item short-form health survey (SF-12). Ankle OA on standard radiographs was scored according to the revised Kellgren and Lawrence (K& L) scale.

Results: 374 patients (56% men) underwent ankle surgery during the defined period. 10% of the patients had a Weber A fracture, 57% a Weber B and 33% a Weber C fracture. Mean age at the time of operation was 42.9 years (+/− 17.1; range 16–86 years). 10–20 years after surgery, 47 patients had died, 126 had left the country and were lost to follow-up, 99 did not respond or refused to participate, and 102 patients were seen at the follow-up visit. These patients did not differ in terms of age, gender distribution, BMI and type of fracture from those who were not seen. The mean duration of follow up was 17.3 years (+/− 3.3). Advanced radiographic OA (K& L grade 3 and 4) was present in 34.3 % of the patients. Symptomatic OA was reported by 34.3 % of the patients (AOFAS pain score < 40). Both clinically symptomatic and radiographic ankle OA was found in 18 patients (17.6%). Function was good in 85% of the cases (total AOFAS hindfoot score between 80 and 100 points; mean total AOFAS hindfoot score 89.9, +/−14.6). The mean Olerud and Molander ankle score was 86.5 (+/−18.7). The general health status (SF-12) was similar to representative values of the general population with a similar mean age.

Conclusion: 10–20 years after operative treatment of an ankle fracture, the incidence of advanced radiographic post-traumatic ankle OA was 35%, symptomatic OA was present in one third of the patients and about one fifth had both. The majority of the patients reported good function.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 28 - 28
1 Jan 2011
Khurana A Guha A Mohanty K Ahuja S
Full Access

Sacroiliac joint (SIJ) is a diarthrodial joint and can often be a source of chronic low back pain complex. We present a percutaneous technique for SIJ fusion and the functional and radiological outcome following arthrodesis with HMA (Hollow modular anchorage; Aesculap Ltd, Tuttlingen) screws.

Fifteen consecutive patients operated for SIJ fusion between Sep 2004 and Aug 2007 were included in the study. The diagnosis was confirmed with MRI and diagnostic injections. Pre-operative and post-operative functional evaluation was performed using SF-36 questionnaire and Majeed’s scoring system. Postoperative radiological evaluation was performed using plain radiographs. The HMA screws packed with bone substitute were implanted percutaneous under fluoroscopic guidance.

The study group included 11 females and 4 males with a mean age of 48.7 years. Mean follow-up was 14 months. Mean SF-36 scores improved from 37 to 80 for physical function and from 53 to 86 for general health. The differences were statistically significant (Wilcoxon signed rank test; p < 0.05). Majeed’s score improved from mean 37 preoperative to mean 79 postoperative. The difference was statistically significant (student t test, p< 0.05). 13 had good to excellent results. The remaining 2 patients had improvement in SF-36 from mean 29 to 48. Persisting pain was potentially due to coexisting lumbar pathology. Intra-operative blood was minimal and there were no post-operative or radiological complications.

Percutaneous HMA screws are a satisfactory way to achieve sacroiliac stabilisation.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 535 - 535
1 Oct 2010
Daniilidis K Fischer F Skuginna A Skwara A Tibesku C
Full Access

Aim: Cementation of tibial implants in total knee arthroplasty is a gold-standard considering the high loosening rates of cementless implants. In contrast, only sparse data exist regarding unicondylar arthroplasty due to limited use. In this study, we compare cemented with cementless unicondylar knee arthroplasty and aim to define both clinical and radiological differences in treatment outcome.

Materials and Methods: In a retrospective study, 106 patients who had undergone a medial unicondylar replacement were examined after a mean postoperative period of 8 years. Of these, 42 patients (median age 81±7 years) had received a cemented and 64 (median age 73±7 years) a cementless knee arthroplasty by the same surgeon while 7 patients were deceased or could not be reached. Well-established clinical (VAS, HSS, KSS, UCLA, WOMAC) and quality of life (SF-36) scores were used to evaluate treatment outcome. X-rays were performed to evaluate periprosthetic loosening zones, according to Ewald’s criteria.

Results: The cementless patient group presented significantly better clinical scores (HSS, KSS, UCLA, WOMAC), except in the Visual Analogue Scale (VAS) for pain assessment. The quality of life was significantly better in the cementless group except in the subgroups concerning physical function, vitality and social role, which resembled normal population. Moreover, radiographic analysis using antero-posterior X-rays revealed significantly more and larger periprosthetic loosening areas in tibial zone 2 in the cementless group.

Conclusion: The inferior clinical results characterising the cemented group could be attributed to the higher mean age. Regarding the radiological loosening zones, we did not detect any differences in the techniques of fixation, although physical activity and mechanical stresses were higher in the cementless group.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_19 | Pages 23 - 23
1 Apr 2013
Iqbal S Iqbal HJ Hyder N
Full Access

Introduction

The distal radius is the most frequently fractured bone in the forearm with an annual fracture incidence in the UK of about 9–37 in 10,000. Restoration of normal anatomy is an important factor that dictates the final functional outcome. A number of operative options are available, including Kirschner wiring, bridging or non-bridging external fixation and open reduction and internal fixation by means of dorsal, radial or volar plates. We designed this study to analyse the clinical and radiological outcome of distal radial fracture fixation using volar plating.

Materials/Methods

Thirty-seven patients with distal radius fractures undergoing open reduction and internal fixation using volar plates were included. Tilt of the fractured distal radial fragment was recorded from the initial radiograph and classification of fractures was done using the Orthopaedic Trauma Association system. The QuickDASH questionnaire was used for evaluation of symptomatic and functional outcome six months to one year after surgery. The radiological outcome was assessed using measurements of radial inclination, ulnar variance and volar tilt. Of the thirty-seven patients, 13 were male and 24 were female. The mean age was 55.6 years (range 18–87 years). According to the AO classification, there were 8 cases each of C2 and C3 fractures, 6 cases of C1 fractures and 3 cases each of class A2, A3, B1 and B3 fractures. There were 2 patients with class B2 fracture.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 495 - 495
1 Sep 2009
Khurana A Guha A Howes J Jones A Davies P Mohanty K Ahuja A
Full Access

Introduction: Sacroiliac joint (SIJ) is a diarthrodial joint and can often be a source of chronic low back pain complex. We present a percutaneous technique for SIJ fusion and the functional and radiological outcome following the arthrodesis.

Aims and Objectives: To evaluate the functional and radiological outcome following percutaneous technique for SIJ fusion with HMA (Hollow modular anchor-age) screws.

Materials and Methods: 15 consecutive patients operated for SIJ fusion between Sep 2004 and Aug 2007 were included in the study. The diagnosis was confirmed with MRI and diagnostic injections. Pre-operative and post-operative functional evaluation was performed using SF-36 questionnaire and Majeed’s scoring system. Postoperative radiological evaluation was performed using plain radiographs. The Hollow modular anchorage (HMA) screws (Aesculap Ltd, Tuttlingen) packed with bone substitute were implanted percutaneous under fluoroscopic guidance

Results: The study group included 11 females and 4 males with a mean age of 48.7 years. Mean follow-up was 14 months. Mean SF-36 scores improved from 37 to 80 for physical function and from 53 to 86 for general health. The differences were statistically significant (Wilcoxon signed rank test; p < 0.05). Majeed’s score improved from mean 37 preoperative to mean 79 postoperative. The difference was statistically significant (student t test, p< 0.05). 13 had good to excellent results. The remaining 2 patients had improvement in SF-36 from mean 29 to 48. Persisting pain was potentially due to coexisting lumbar pathology. Intra-operative blood was minimal and there were no post operative or radiological complications in any patient.

Conclusion: Percutaneous HMA screws are a satisfactory way to achieve sacro-iliac stabilisation.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 29 - 30
1 Mar 2009
Biedermann R Donnan L Gabriel A Wachter R Krismer M Behensky H
Full Access

Periacetabular osteotomy (PAO) is a well established method to treat hip dysplasia in the adult. There are, however, a number of complications associated with this procedure as well as a time related deterioration in the grade of osteoarthritis that can influence the long term result. It is essential that patients are fully informed as to the effectiveness of PAO, the likelihood of complications and their influence on the subjective outcome prior to giving consent for surgery. Generic outcome measures offer the opportunity to determine treatment efficacy and the influence on the outcome by complications.

60 PAOs on 50 patients were investigated retrospectively after a mean follow up of 7.4 years. The patients’ self reported assessment of health and function was evaluated by the SF-36 and the WOMAC questionnaires at last follow-up. 40 healthy persons served as a control group.

The centre-edge angle improved from a mean of 8.7° to 31.5°. The weight bearing surface improved from a mean lateral opening of 8.7° to 4.2°. The degree of osteoarthritis improved in one case, remained unchanged in 20 and deteriorated in 17. There was a tendency of higher CE-angles towards a higher rate of deterioration, indicating that overcorrection may increase osteo-arthritic degeneration. 13 of the 60 interventions had no complications. Minor complications occurred in 25 (41%) interventions and in 22 (37%) at least one major complication occurred. SF-36 summary measure was 76.4 for PAO patients and 90.3 for the control group. Mean WOMAC score was 25.1. The severity of ectopic bone formation, incidence of postoperative peroneal nerve dysfunction and delayed wound closure did not influence the subjective result. Patients with major complications had a similar subjective outcome as patients with minor or no complications, but persistent dysesthesia due to lateral femoral cutaneous nerve dysfunction led to a worse subjective function as assessed with the WOMAC score.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 31 - 31
1 Sep 2014
Mughal A Kruger N
Full Access

Purpose of Study

Debate exists in the literature about the surgical management of sub-axial cervical burst fractures regarding the approach and types of fixation of these injuries. Our Acute Spinal Injury (ASCI) unit prefers anterior only cervical corpectomy and plate fixation in the management of these injuries. The objective of this study was to radiologically assess the long term outcomes (minimum 2 yrs) of our series.

Patients and Methods

Patients were identified using the Acute Spinal Injury Unit (ASCI) database that had had anterior only corpectomy and plate fixation for trauma as a standardised procedure between 2006 and 2009. Initial post-op radiological review included the sagittal alignment, hardware characteristics and surgical technique. Radiological review after a minimum of 24 months involved the union, sagittal alignment, hardware characteristics, graft incorporation and adjacent level degeneration at the site of injury.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 25 - 25
1 Jul 2012
Robb C Dixon J Parker L Baloch K Pynsent P
Full Access

Aims

The purpose of our study was three fold; firstly to assess the survival of closing wedge high tibial osteotomies (CWHTO), secondly to assess any clinical factors or radiological alignment which may affect survival and thirdly to assess the change in tibial inclination and patella height.

Methods

Details of 51 patients undergoing CWHTO for varus gonarthrosis between 1999 and 2007 were assessed for age, BMI, gender, range of movement, meniscal integrity and grade of arthritis. Radiological evaluation included pre and post-operative femoro-tibial axis, tibial slope and patella height. Outcome was also evaluated by Oxford knee score and UCLA activity score. Failure was considered as conversion to arthroplasty.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 142 - 142
1 Apr 2012
Dhir J Carpenter C Pande R Pyrovolou N Ahuja S
Full Access

We do know that the use of stand-alone cage with no plate is prone to subsidence and segmental kyphosis. Cage and plate construct are prone to adjacent level ossification. Zero P (Synthes, UK) cage combines the functionality of spacer and anterior plate.

Radiological evaluation of subsidence of cervical spine after anterior cervical interbody fusion using Zero P cage system.

Method: Retrospective review of radiographic records of patients undergoing surgery between June 2008- Oct 2009. We evaluated lateral cervical standing radiographs before, after, 6 weeks, 3, 6 months of surgery. We measured subsidence (using Total Intervertebral Height (TIH). All measurements were done using Web 1000 (Impax Agfa). Two level was treated as single segment. Subsidence > 3mm was considered significant.

20 patients (11 male: 9 female) with median age of 51 yrs (40-65) underwent one (n=10) or two level (n= 10) cervical fusion. Immediately post-op there was increase in TIH in one and two level group by 1.74mm (1.61 and 4.25mm (1.48 respectively, which at 6 months reduced to 1.05mm (0.24 (p< 0.003) and 1.32mm (1.29 (p< 0.085) at 6 months respectively. Subsidence was seen in all cases and was rapid in first 3 months and then tailed off. It was significant (> 3mm) only in 2/20 (2%) patients at 6 months.

Early results indicate that spine alignment is maintained radiologically with no associated complications as screw loosening, cage extrusion etc.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 368 - 368
1 May 2009
Patterson P Bonner T McKenna D Womack J Briggs P Siddique M
Full Access

Introduction: The Scarf osteotomy for the treatment of hallux valgus is achieving popularity, but no comparative study has proven the efficacy of this procedure over other first metatarsal osteotomies.

We present a retrospective comparative review of the radiological outcomes of Chevron and Scarf with Akin osteotomy in the treatment of hallux valgus.

Materials and Methods: The radiological outcomes of 40 first metatarsal osteotomies, 20 Chevron and 20 Scarf with Akin are presented. The radiological parameters studied included hallux valgus angle, hallux inter-phallangeus, intermetatarsal angle, sesamoid station and foot width.

Results: The mean post-operative hallux valgus angles (HVA’s) were: Chevron mean HVA 17.90, standard deviation 7.360, standard error 1.65. Scarf with Akin osteotomy mean HVA 9.550, standard deviation 6.60, standard error 1.4. The difference in postoperative HVA between the two operations was statistically significant (p< 0.001).

The mean post-operative intermetatarsal angles (IMA) were: Chevron mean 8.050, standard deviation 2.560, standard error 0.57. Scarf with Akin mean 7.220, standard deviation 2.56, standard error 0.57. The difference in postoperative IMA between the two groups did not achieve statistical significance.

The mean change in IMA for each was: Chevron mean increment 4.90 Standard deviation 2.290, standard error 0.51. Scarf with Akin mean increment 6.680, standard deviation 4.130, and standard error 0.88. The difference in alteration of IMA between the two groups did not achieve statistical significance.

Discussion and Conclusion: We conclude that as there was no difference in the distribution of post-op IMA for Scarf and Chevron osteotomies that the added affect of an Akin osteotomy may contribute to the Scarf to produce the better correction in hallux valgus angle.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 4 - 4
1 Mar 2009
bhadra A Raman A Rai A Casey A Crawford R
Full Access

AIM: To compare the outcomes between two different surgical techniques for cervical myelopathy (skip laminectomy vs laminoplasty).

METHODS: Cervical skip laminectomy is a new technique described by Japanese surgeons in 2000. The advantage of this procedure over the other conventional techniques is it addresses multilevel problem in a least traumatic way without need for instrumentation.

We are comparing the above two techniques with 25 patients in each group operated by 3 surgeons. The first group had conventional laminoplasty and the second group underwent the skip laminectomy. The groups were comparable in age, sex, pathology and clinical presentation. Both these group had clinical outcome measurements using SF 12 questionnaires, pre and postoperative clinical assessment with standard tools performed by independent surgeon and a specialist spinal physiotherapist. We also routinely performed pre and postoperative MRI scans to assess the adequacy of decompression.

RESULTS & CONCLUSION: There was no significant difference in the outcome of these patients in terms of the operative technique, hospital stay, clinical and radiological outcome. However skip laminectomy is relatively a easier procedure to perform, while the laminoplasty does need instrumentation.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 181 - 181
1 May 2011
Vasireddy A Navadgi B Deo S Satish V Lowdon I
Full Access

Purpose of study: With the increasing demand for arthroplasty surgery, it is important to maintain a high quality of care. We describe a clinical governance framework for a simple, easy to implement method of assessing and monitoring radiological outcome following total knee arthroplasty.

Methods: We completed a two-year prospective study (January 2006 to December 2007 inclusive) of all total knee arthroplasty operations. This included 1,295 procedures, the majority of which were undertaken by two Consultant Surgeons and up to eight independent middle grade surgeons. The two Consultant Knee Surgeons assessed component position on standard post-operative weight-bearing antero-posterior and lateral knee radiographs on a weekly basis. They were blinded to both the patient and surgeon details, and used our own simple grading system, whose weighted Kappa variance showed ‘moderate’ interobserver (K = 0.41) and intraobserver reliability (K = 0.51). Our system comprised of only three ordinal scores, which were good (score of 1), acceptable (score of 2) and poor (score of 3).

Results: We provided individual surgeons with their results on a six-monthly basis. The average score for all the surgeons was good. The scores of the independent middle-grade surgeons were analysed by the Consultants, and feedback was provided in the form of formal advice and supervised surgery sessions. Repeat proportional analysis of their radiological scores showed significant improvements for all the individual surgeons (Pearson-Chi Square p value < 0.05).

Conclusions: Clinical governance is an important facet of excellence in medical practice. Our system allows continued prospective assessment of radiological outcome following total knee arthroplasty. By utilising such systems and ensuring an atmosphere of clinical excellence, we are able to employ more surgeons and undertake an increased workload, whilst maintaining high standards. This assessment tool can also be used to assess and appraise trainees during their progression.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 238 - 239
1 Sep 2005
Wardlaw D Choudhary S Muthukumar T Gibson S
Full Access

Study Design: A prospective randomised controlled trial with blind radiological assessment.

Objective: To assess the radiological outcome of instrumented posterolateral lumbar fusion in a prospective randomised study comparing the use of allograft (fresh frozen human femoral head) to autologous bone (from the posterior iliac crest) using a validated method.

Methods: Sixty-nine patients having instrumented postero-lateral fusion using the Steffee plate were randomised to one of two groups, to receive either allograft bone or autologous bone. The same surgeon using the same surgical technique performed or supervised all cases. The radiological results of the two groups were assessed as well as the quality of fusion.

Outcome measures: The radiographs were assessed for fusion or non-fusion by three independent observers using the same criteria, and a second time by one of the observers. The Kappa scores for the inter-observer and intra-observer agreement were calculated. Some of these patients had fusion status verified by the gold standard of surgical exploration and the sensitivity and specificity calculated. The clinical outcome is the subject of a different paper.

Results: Both the inter-observer and intra-observer kappa scores (k) were 100%. The sensitivity of the method was 87.9% and the specificity was 100%. Thirty-seven patients received allograft and 32 patients received autograft. There was no significant difference in the fusion rate, or the quality and quantity of the graft between the groups.

Conclusions: There is no difference in the fusion rates comparing the use of autograft and allograft for postero-lateral instrumented lumbar fusion.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 23 - 23
1 Mar 2005
Wardlaw D Choudhary S Muthukumar T Gibson S
Full Access

To assess the radiological outcome of instrumented posterolateral lumbar fusion in a prospective randomised study comparing the use of allograft (fresh frozen human femoral head) to autologous bone (from the posterior iliac crest), using a validated method.

One hundred and twenty four radiographs of patients who had undergone instrumented posterolateral spinal fusion were assessed for fusion or non-fusion by three independent observers using the same criteria, and a second time by one of the observers. The Kappa scores for the inter-observer and intra-observer agreement were calculated. Thirty-three of these patients had fusion status verified by the gold randomised to one of two groups, to receive either allograft bone or autologous bone. The same surgeon using the same surgical technique performed or supervised all cases. The radiological results of the two groups were assessed as well as the quality of fusion.

Both the inter-observer and intra-observer kappa scores (k) were 100%. The sensitivity of the method was 87.9% and the specificity was 100%. Thirty-seven patients received allograft and 32 patients received autograft. There was no significant difference in the fusion rate, or the quality and quantity of the graft between the groups.

There is no difference in the fusion rates comparing the use of autograft and allograft for posterolateral instrumented lumbar fusion.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 589 - 589
1 Oct 2010
Penna S Nalla R Sharma R
Full Access

Aim: We report radiological outcome following percutaneous minimally invasive corrention of Hallux Valgus using K-wire fixation.

Methods: We followed 15 patients (11 bilateral operations) who had above procedure for Hallux Valgus deformity correction. All patients had pre operative and post operative x-rays assessed for Hallux Valgus angle, 1st Intermetatarsal angle and Distal Metatarsal Articular angle. We also collected clinical data including deformity correction and complications.

Results: Mean age of the patients was 55.47(SD 14.27). Of the 15 procedures 11 had bilateral operations and 4 had only one side operated (total 14 right sided 12 left sided operations). Mean duration of follow up was 85.47 days (range 29 to 259). The pre operative mean Hallux Valgus angle was 37.05(SD 6.49, range 28 to 49) where as post operative it was 11.32(SD 9.07, range 0 to 33). The pre operative mean 1st Intermetatarsal angle was 16.46(SD 2.74, range 11 to 21) where as post operative it was 5.48(SD 3.62, range 1 to 16). The pre operative mean Distal metatarsal articular angle was 35.36(SD 8.38, range 18 to 51) where as post operative it was 8.29(SD 9.13, range 0 to 38). Clinically one great toe had infection post operatively requiring early removal of K-wires resulting in residual deformity. One had mild bilateral recurrence, two had mild unilateral recurrence. These patients did not require any further surgery.

Conclusion: Above results indicate that Percutaneous Minimally invasive Hallux Valgus correction using K-wire fixation showed good radiological correction in various angles measured to quantify Hallux Valgus deformity.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 147 - 147
1 Feb 2003
du Toit G Vlok G
Full Access

Most spinal pedicle fixation systems used in this country are imported and expensive. They mostly employ rigid or semi-rigid screws with a known and significant rate of implant failure. Though they are often designed for ease of insertion, many are difficult to remove.

This study investigated the radiological outcome of a dynamic spinal fixation system developed in South Africa with the aims of reducing costs, improving ease of insertion and removal, reducing the rate of implant failure, and at the same time meeting international standards.

A University Ethics Committee approved this study of 439 patients in whom the device was used in spinal surgery between 1997 and 2002. Of these patients, 121 had follow-up radiographs taken more than one year after surgery. These radiographs were independently reviewed and form the basis of this study.

In 93.4% of patients, the fusion was radiographically solid. The state of fusion was uncertain in 4.1%, and fusion had failed in 2.5%. Screw breakage occurred in 0.3%. There were no rod breakages. In 1% of patients there was evidence of screw-bone loosening. There were no signs of screw-rod breakage or loosening.

The device produces a satisfactory rate of fusion with a very low rate of implant failure. Awarded ISO 9001:2001 certification and the CE mark, it meets international standards at considerably reduced cost.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages - 38
1 Mar 2002
Assi C Faline A Canovas F Bonnel F
Full Access

Purpose: A pre- and postoperative radiographic analysis of 50 total knee arthroplasties (TKA) was performed to determine the femorotibial correction angle and the tibial and femoral mechanical angles obtained as a function of the initial bony deformity. The preoperative angle beyond which correction was not achieved was determined.

Material and methods: This prospective single-centre study included 50 TKA (25 men and 25 women), mean age 69.1 years (range 53–83). Degenerative disease involved the right knee in 21 cases and the left knee in 29. A Wallaby I TKA (semi-restrained with preservation of the posterior cruciate ligament) was implanted in all cases. Three angles were calculated on the AP loaded knee: AFT (femorotibial angle), AFM (femoral mechanical angle), ATM (tibial mechanical angle). For each angle, statistic analysis was performed on four groups of patients: group I: overall population, group II: patients with normal axis (178°< AFT< 182°; 88°< AFM< 92°; 88)< ATM< 92°), group III: patients with varus (AFT> 182°; AFM> 92°; ATM> 92°), and group IV: patients with valus (AFT< 178°; AFM< 88°; ATM< 88°). Non-parametric tests (Spearman rank test and MacNemar symmetry test) were performed on SAS software for statistical analysis with p< 0.05 considered as significant.

Results: Pre- and postoperative AFT showed: significant improvement of the mean (> 3.44° in group I, > 6.87° in group III, and > 6.12° in group IV). There was no significant difference in group II. Pre- and postoperative AFM showed: constant but non-significant improvement in groups I and III (> 3°) and constant and significant improvement in groups III and IV (> 2.5°). Pre- and postoperative ATM showed: significant improvement in groups I and III (> 3°), constant but non-significant improvement in group IV (n=4). There was no group II. An ATM > 94° was the threshold angle beyond which correction was not obtained.

Discussion: Taken together, the results of this study confirm the reliability of the Wallaby I instrumentation for achieving a correct postoperative mechanical axis. These results are comparable with data in the literature (with or without preservation of the posterior cruciate ligament). However, the correction of the bony deformity obtained depended uniquely on the initial deformity of the tibia. Extreme deformity of the tibia should be corrected with osteotomy or with a more restrained prosthesis.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 437 - 437
1 Aug 2008
Freeman B Hussain N Watkins R Webb J
Full Access

Introduction: Patient questionnaires permit a direct measure of the value of care as perceived by the recipient. The Scoliosis Research Society outcomes questionnaire (SRS-22) has been validated as a tool for self-assessment. We investigated the correlation between SRS-22 and a detailed radiological outcome two years following anterior correction of Thoraco-Lumbar Adolescent Idiopathic Scoliosis (TL-AIS).

Methods: The SRS-22 questionnaire was completed by 30 patients two years following anterior correction of TL-AIS. Pre-operative, post-operative and two year follow-up radiographs of all 30 patients were assessed. The following parameters were measured at each time point:

Primary Cobb angle,

Secondary Cobb angle,

Coronal C7-midsacral plumb line,

Apical Vertebra Translation (AVT) of primary curve,

AVT of the secondary curve,

Upper instrumented vertebra (UIV) translation,

UIV tilt angle,

Lower instrumented vertebra (LIV), 8) LIV tilt angle

Apical Vertebra Rotation (AVR) of the primary curve,

Sagittal C7-posterior corner of sacrum plumb line

T5-T12 angle,

T12-S1 angle,

shoulder height difference.

The percentage improvements for each were noted. Correlation was sought between Total SRS score, each of the five individual domains and various radiographic parameters listed above by quantifying Pearson’s Correlation Coefficient (r).

Results: Percentage improvement in primary Cobb angle (r = 0.052), secondary Cobb angle (r = 0.165) and AVT of the primary curve (r = −0.353) showed little or no correlation with the SRS-22 total score or any of its five domains. Significant inverse correlation was found between the UIV tilt angle at two years and the SRS-22 (r = −0.516). Lateral radiographs however showed little or no correlation between thoracic kyphosis (r = 0.043) and SRS-22.

Conclusion: The SRS-22 outcomes questionnaire does not correlate with most of the radiographic parameters commonly used by clinicians to assess patient outcome.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 451 - 451
1 Aug 2008
Hussain N Freeman BJC Watkins R Webb JK
Full Access

Introduction: Patient questionnaires permit a direct measure of the value of care as perceived by the recipient. The Scoliosis Research Society outcomes questionnaire (SRS-22) has been validated as a tool for self-assessment. We investigated the correlation between SRS-22 and a detailed radiological outcome two-years following anterior correction of ThoracoLumbar Adolescent Idiopathic Scoliosis (TL-AIS).

Methods: The SRS-22 questionnaire was completed by 30 patients two-years following anterior correction of TL-AIS. Pre-operative, post-operative and two-year follow-up radiographs of all 30 patients were assessed. The following parameters were measured at each time point: 1) Primary Cobb angle, 2) Secondary Cobb angle, 3) Coronal C7-midsacral plumb line, 4) Apical Vertebra Translation (AVT) of primary curve, 5) AVT of the secondary curve, 6) Upper instrumented vertebra (UIV) translation, 7) UIV tilt angle, 8) Lower instrumented vertebra (LIV), 8) LIV tilt angle 9) Apical Vertebra Rotation (AVR) of the primary curve, 10) Sagittal C7-posterior corner of sacrum plumb line 11) T5–T12 angle, 12) T12-S1 angle, 13) shoulder height difference. The percentage improvements for each were noted. Correlation was sought between Total SRS score, each of the five individual domains and various radiographic parameters listed above by quantifying Pearson’s Correlation Coefficient (r).

Results: Percentage improvement in primary Cobb angle (r = 0.052), secondary Cobb angle (r = 0.165) and AVT of the primary curve (r = −0.353) showed little or no correlation with the SRS-22 total score or any of its five domains. Significant inverse correlation was found between the UIV tilt angle at two years and the SRS-22 (r = −0.516). Lateral radiographs however showed little or no correlation between thoracic kyphosis (r = 0.043) and SRS-22.

Conclusion: The SRS-22 outcomes questionnaire does not correlate with most of the radiographic parameters commonly used by clinicians to assess patient outcome.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 86 - 86
1 Mar 2006
Arora J Ogden A
Full Access

Aim: To assess the medium term survival and radiological outcome of primary cemented modular Freeman Samuelson total knee replacement at Dumfries and Galloway Royal Infirmary, UK

Material and methods: 115 patients (118 knees), who underwent primary cemented modular Freeman Samu-elson total knee replacement from 1991 to1998, were reviewed retrospectively. Proximal cementing technique was used ti fix the metal backed tibial implant. The follow-up x-rays were also reviewed and presence of osteolysis, aseptic loosening and polyethylene wear was noted. The Knee Society radiological evaluation was used to record the osteolysis and the WOMAC score was used to evaluate functional outcome.

Results: The operation was performed for osteoarthritis (87), rheumatoid arthritis (23), psoriasis (4), Pagets disease (2), avascular necrosis (1) and gout (1). The average follow-up was 7.25 yrs (range 5–13 yrs). At the latest review 25 patients had died and 14 had undergone revision surgery. The indications for revision were aseptic loosening and polyethylene wear (3), osteolysis (3), infection (6), instability (1) and loosening of patellar component (1). Patella was resurfaced in 80 patients using press fit uncemented all-polyethylene component. Two patients with unreplaced patella underwent re-operation for patellar resurfacing due to anterior knee pain. Cumulative survival of the implant at 10 years was 93.4% for revision due to aseptic loosening or osteolysis and 86.8% for revision due to any cause. Radiolucent lines were observed in 22 patients. In 4 of these patients, the radiolucent lines were progressive and 3mm or more in size. Osteolytic lesions were seen in 10 patients. None of the patients with osteolysis or radiolucent lines were symptomatic. There was no statistical association between thickness of polyethylene and presence of osteolysis or occurrence of aseptic loosening (chi squared test)

Conclusion: Freeman Samuelson knee replacement provided good and predictable medium term outcome in our patients with tricompartmental arthritis of knee. The results of uncemented press fit all-polyethylene patellar replacement were also excellent. However, the high incidence of osteolysis even though asymptomatic, at an average follow-up of 7.25 yrs is a matter of some concern. Proximal cementing technique may lead to increased incidence of osteolysis and should be avoided in the modular Freeman Samuelson total knee replacement


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 424 - 424
1 Jul 2010
Vasireddy A Navadgi B Deo S Satish V Lowdon I
Full Access

Purpose of study: With the increasing demand for arthroplasty surgery, it is important to maintain a high quality of care. We describe a clinical governance framework for a simple, easy to implement method of assessing and monitoring radiological outcome following total knee arthroplasty.

Methods: We completed a two-year prospective study (January 2006 to December 2007 inclusive) of all total knee arthroplasty operations. This included 1,295 procedures, the majority of which were undertaken by two Consultant Surgeons and up to eight independent middle grade surgeons. The two Consultant Knee Surgeons assessed component position on standard post-operative weight-bearing antero-posterior and lateral knee radiographs on a weekly basis. They were blinded to both the patient and surgeon details, and used our own simple grading system, whose weighted Kappa variance showed ‘moderate’ interobserver (K = 0.41) and intraobserver reliability (K = 0.51). Our system comprised of only three ordinal scores, which were good (score of 1), acceptable (score of 2) and poor (score of 3).

Results: We provided individual surgeons with their results on a six-monthly basis. The average score for all the surgeons was good. The scores of the independent middle-grade surgeons were analysed by the Consultants, and feedback was provided in the form of formal advice and supervised surgical sessions. Repeat proportional analysis of their radiological scores showed significant improvements for all the individual surgeons (Pearson-Chi Square p value < 0.05).

Conclusions: Clinical governance is an important facet of excellence in medical practice. Our system allows continued prospective assessment of radiological outcome following total knee arthroplasty. By utilising such systems and ensuring an atmosphere of clinical excellence, we are able to employ more surgeons and undertake an increased workload, whilst maintaining high standards. This assessment tool can also be used to assess and appraise trainees during their progression.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 369 - 369
1 Sep 2012
Rodriguez Vega V Cecilia D Suarez L Jorge A Auñon I Rojo M Blanco D Guimera V Bravo B Garcia L Resines C
Full Access

Introduction

Distal radius fractures are one of the most common injuries attended in hospitals. Throughout the years the treatment has change from simple cast to ORIF.

Objectives

To compare the functional and radiographic results in the treatment of the distal intrarticular radial fractures treated by volar buttress plate (T plate AO® Synthes, Oberdorf, Suiza) and fixed volar angle locking plate (DVR® Depuy, Warsaw, Indiana, USA).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 72 - 72
1 May 2012
Hadi M Walker C Sheriff R Attar F Attar G
Full Access

Background & aim

There have been many operations described for the treatment of hallux valgus deformities and b ette done separately with variable success rates. Our aim is to radiologically assess the outcome following simultaneous osteotomies to the 1st and 5th metatarsals in symptomatic patients with splay foot. To our knowledge, this procedure has not been described in the literature yet.

Materials & method

9 symptomatic patients (12 feet) were included in the study. The pre-operative and post-operative X-rays were assessed and the hallux valgus angles, 1st and 2nd intermetatarsal angles, distal metatarsal articular angles (DMAA), 4th and 5th intermetatarsal angles, maximum widths of the 1st and 5th metatarsal heads and the maximum distance between 1st and 5th metatarsals were calculated. The improvement in the angles and distances post-operatively were then assessed for statistical significance using Non-parametric paired T tests.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 110 - 110
1 Feb 2012
Hussain N Freeman B Watkins R He S Webb J
Full Access

Our prospective observational study of patients treated for Thoracolumbar Adolescent Idiopathic Scoliosis (AIS) by anterior instrumentation aimed at investigating the correlation between the radiographic outcome and the recently-developed scoliosis research society self-reported outcomes instrument (SRS-22) which has been validated as a tool for self-assessment in scoliosis patients. Previous patient based questionnaires demonstrated poor correlation with the radiological parameters.

Materials and Methods

Pre-operative, post-operative and two years follow-up radiographs of 30 patients were assessed. Thirteen radiographic parameters including Cobb angles and balance were recorded. The percentage improvements for each were noted. The SRS-22 questionnaire was completed by all patients at final follow-up. Correlation was sought between each radiographic parameter, total SRS score and each of the five domains by quantifying Pearson's Correlation Coefficient (r).

Results

Percentage improvement in primary Cobb angle (r = 0.052), secondary Cobb angle (r = 0.165), apical vertebra translation of the primary curve (r = -0.353), thoracic kyphosis (r = 0.043) and lumbar lordosis (r = 0.147) showed little or no correlation with the SRS-22 total score and its five individual domains. Significant inverse correlation was found between the upper instrumented vertebra angle and at follow-up and SRS-22 (r = -0.516). The same was true for Sagittal plumb line shift at final follow up (r = -0.447).


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 781 - 786
1 Jun 2010
Zhao G Yamamoto T Ikemura S Motomura G Mawatari T Nakashima Y Iwamoto Y

We investigated the factors related to the radiological outcome of a transtrochanteric curved varus osteotomy in patients with osteonecrosis of the hip. We reviewed 73 hips in 62 patients with a mean follow-up of 12.4 years (5 to 31.1). There were 28 men and 34 women, with a mean age of 33.3 years (15 to 68) at the time of surgery. The 73 hips were divided into two groups according to their radiological findings: group 1 showed progression of collapse and/or joint-space narrowing; group 2 had neither progressive collapse nor joint-space narrowing. Both of these factors and the radiological outcomes were analysed by a stepwise discriminant analysis. A total of 12 hips were categorised as group 1 and 61 as group 2. Both the post-operative intact ratio and the localisation of the necrotic lesion correlated with the radiological outcome. The cut-off point of the postoperative intact ratio to prevent the progression of collapse was 33.6%, and the cut-off point to prevent both the progression of collapse and joint-space narrowing was 41.9%.

The results of this study indicate that a post-operative intact ratio of 33.0% is necessary if a satisfactory outcome is to be achieved after this varus osteotomy.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 332 - 332
1 Jul 2011
De Man H Sendi P Maurer TB Zimmerli W Graber P Ilchmann T Ochsner P
Full Access

Introduction: In treatment for prosthetic hip joint infection (PHJI), the advantages of a 1-stage exchange over the classic 2-stage approach are the lower morbidity and earlier rehabilitation. Secondly, a recently published treatment algorithm for PHJI using well-defined selection criteria for 1-stage exchange had a 85–100% rate of cure for infection. Patient satisfaction after hip surgery is highly influenced by the functional result. We hypothesized that in our used algorithm the functional and radiological outcomes after a 1-stage exchange due to an implant-associated infection would be similar to a matched control group of 1-stage exchange due to aseptic loosening.

Material and Methods: Twenty-two cases (21 patients), with PHJI according to a well-defined definition, after 1-stage exchange of the prosthesis strictly according to the algorithm, with index-surgery between april 1996 and october 2004, were included in the studygroup. Case-matching was performed with aseptic revised cases for previous surgery, type of implant, use of transfemoral osteotomy, Charnley score, duration of follow-up, age, and sex. Outcome measures were perioperatively complications, functional results (Harris hip score, limping, and use of walking support) at two years, and the occurrence of revision for any reason and radiological loosening at latest follow-up. All outcomes were compared between both groups and with the results of the two stage revisions in our cohort. Finally, the eradication of infection was scored.

Results: In 86% of the 1-stage group (n = 19) there was an event-free follow-up for ≥ 2 years. The mean Harris hip score was 84, the incidence of limping 20% and 10% required two crutches. Two stems were revised due to aseptic loosening. Both functional and radiological outcomes were not different from the matched control group.

In the 2-stage group (n = 50) results were lower but not significantly, with 80, 30% and 28% respectively, and 2 stems and 1 cup were revised due to aseptic loosening.

One case (after one stage) developed an infection with a different pathogen and one case (after two stage exchange) had a relaps of infection.

Conclusion: By using the identical surgical technique in both septic and aseptic revision hip surgery, functional results are comparable between groups. These results indicate that 1-stage exchange according to a strict algorithm leads to a successful outcome in both maintaining functional mobility and eradicating infection.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 421 - 421
1 Nov 2011
Cazeneuve J Hasssan Y Hilaneh A Kermad F Brunel A
Full Access

Synthesis and hemi-prosthesis give well known radiological results for acute proximal complex humeral fractures in elderly population. We wanted to expose the radiological outcome of the reverse concept in this indication.

From 1993 to 2008, forty four DELTA III were implanted for thirty three three-part and four-part displacements and eleven fracture-dislocations, in 3 males for 41 females, with an average age of seventy five years. The results were estimated with AP and LAMY profile Xrays.

Because of ten deceases and three moving, thirty one cases were reviewed with a mean follow-up of 6.3 years, range 1 to 15. The radiographs showed : two 2-mm thick borders on the glenoid at four and eight years with a scapular notch at 11 years and an aseptic loosening of the base plate at 12 years with a broken polar inferior screw. The patient underwent an easy surgical revision because of a fair bone stock. There was no wear of the polyethylene.

According to the NEROT classification, nineteen inferior scapular notches were observed with a mean occurrence time of 4.6 years. The seven type-1 notches appeared at a mean of 2 years and the five type-2 notches at a mean of 4.3 years. We observed four type-3 notches which reached the inferior screw at 5,6,7 and 8 years, and three type-4 notches which extended beyond the inferior screw at 6,7 and 8 year follow-up, respectively. There seem to be two distinct patters of notches: mechanical, stable proximal humeral bone loss because of an impingement between the humeral component and the inferior scapular pillar and biological, progressive in size, evolving over time with proximal humeral bone loss because of polyethylene disease; the longer the follow-up, the more severe the notch. Fourteen inferior spurs, stable after emergence, were reported with a mean occurrence time of 2.5 years range 1 to 6 years. One joint ossification occurred at 6 months and was stable at 6 year follow-up. The humeral results consisted in five medial (5,6,710, and 11 years) proximal bone looses and three bone-cement interface medial borders on the two thirds of the height of the stem at a mean follow-up of 5 years. In these eight cases, there was a notch associated. We reported one case of septic humeral loosening at 2 year follow-up.

For acute proximal humeral complex fractures in elderly population, when re-fixation of the tubercles on the classical orthopaedics devices is impossible, the use of a DELTA III prosthesis shows, with a mean follow-up of 6.3 years, worrying images in 70% of the cases.

These images are on the glenoid in 70% of the cases, appeared before seven years in 86% and are progressive in 50% of the cases. But, we have only one re-intervention for an aseptic loosening of the base plate at a twelve year evolution. New developments in design and bearing surfaces and a more long term results will probably provide more durable utilization of the reverse concept in this indication.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 220 - 220
1 May 2006
Raman MA Rai MA Marshall DT Crawford MR
Full Access

There are numerous surgical techniques described for cervical decompression for multilevel cervical stenosis. Cervical skip laminectomy is a new technique described by Japanese surgeons in 2000. The advantage of this procedure over the other conventional techniques is it addresses multilevel problem in a least traumatic way without need for instrumentation. It is also described to have lesser incidence of post operative axial symptoms, range of motion and loss of cervical lordosis.

We are presenting our prospective case series of 23 patients who had this procedure in our institution between 2002 and 2004. Of these 16 patients are at least 6 months from their operation. We performed clinical outcome measurements using SF12 questionnaires, pre and postoperative clinical assessment performed by independent surgeon and a specialist spinal physiotherapist. We also routinely performed pre and postoperative MRI scans to assess the adequacy of decompression (Done by our musculoskeletal radiologist).

Our study showed a good clinical and radiological outcome with this relatively simple new procedure. This has become our standard operation for our patients with multilevel cervical stenosis with cervical myelopathy.