header advert
Results 1 - 64 of 64
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 106 - 106
2 Jan 2024
Shin H
Full Access

Recently, technologies to culture one or more cell types in three dimensions have attracted a great deal of attention in tissue engineering. Particularly, the improved viability, self-renewal capacity, and differentiation potential have been reported for stem cell spheroids. However, it is crucial to modulate spheroid functions with instructive signals to use multi-cellular spheroids in tissue engineering. We have been developing ECM-mimicking fibrous materials decorated with cell-instructive cues, which were incorporated within 3D stem cell spheroids to fine-tune their functions as modular building blocks for bottom-up tissue-engineering applications. In particular, we created composite spheroids of human adipose-derived stem cells (hADSCs) incorporating nanofibers coated with instructive signal of either transforming growth factor-β3 or bone morphogenetic growth factor-2 for chondrogenesis or osteogenesis of stem cells, respectively. The bilayer structure of osteochondral tissue was subsequently mimicked by cultivating each type of spheroid inside 3D-printed construct. The in vitro chondrogenic or osteogenic differentiation of hADSCs within the biphasic construct under general media was locally regulated by each inductive component. More importantly, hADSCs from each spheroid proliferated and sprouted to form the integrated tissue with interface of bone and cartilage tissue. This approach may be applied to engineer complex tissue with hierarchically organized structure.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 657 - 662
1 Jun 2023
Meaike JJ Meaike JD Collins MS Bishop AT Shin AY

Aims

The benefit of MRI in the preoperative assessment of scaphoid proximal fragment vascularity remains controversial. The purpose of this study is to compare preoperative MRI findings to intraoperative bleeding of the proximal scaphoid.

Methods

A retrospective review of 102 patients who underwent surgery for scaphoid nonunion between January 2000 and December 2020 at a single institution were identified. Inclusion criteria were: isolated scaphoid nonunion; preoperative MRI assessing the proximal fragment vascularity; and operative details of the vascularity of the proximal fragment with the tourniquet deflated. MRI results and intraoperative findings were dichotomized as either ‘yes’ or ‘no’ for the presence of vascularity. A four-fold contingency table was used to analyze the utility of preoperative MRI with 95% confidence intervals. Relative risk was calculated for subgroups to analyze the association between variables and MRI accuracy.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 65 - 65
23 Feb 2023
Ting R Rosenthal R Shin Y Shenouda M Al-Housni H Lam P Murrell G
Full Access

It is undetermined which factors predict return to work following arthroscopic rotator cuff repair. We aimed to identify which factors predicted return to work at any level, and return to pre-injury levels of work 6 months post-arthroscopic rotator cuff repair.

Multiple logistic regression analysis of prospectively collected demographic, pre-injury, preoperative, and intraoperative data from 1502 consecutive primary arthroscopic rotator cuff repairs, performed by a single surgeon, was performed to identify independent predictors of return to work, and return to pre-injury levels of work respectively, 6 months post-surgery.

Six months post-rotator cuff repair, 76% of patients returned to work (RTW), and 40% returned to pre-injury levels of work (Full-RTW). RTW at 6 months was likely if patients were still working after their injuries, but prior to surgery (Wald statistic [W]=55, p<0.0001), were stronger in internal rotation preoperatively (W=8, p=0.004), had full-thickness tears (W=9, p=0.002), and were female (W=5, p=0.030). Patients who achieved Full-RTW were likely to have worked less strenuously pre-injury (W=173, p<0.0001), worked more strenuously post-injury but pre-surgery (W=22, p<0.0001), had greater behind-the-back lift-off strength preoperatively (W=8, p=0.004), and had less passive external rotation range of motion preoperatively (W=5, p=0.034). Patients who were still working post-injury, but pre-surgery were 1.6-times more likely to RTW than patients who were not (p<0.0001). Patients who nominated their pre-injury level of work as “light” were 11-times more likely to achieve Full-RTW than those who nominated “strenuous” (p<0.0001).

Six months post-rotator cuff repair, a higher patient-rated post-injury, but pre-surgery level of work was the strongest predictor of RTW. A lower patient-rated pre-injury level of work was the strongest predictor of Full-RTW. Greater preoperative subscapularis strength independently predicted both RTW, and Full-RTW.


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1380 - 1385
2 Aug 2021
Kim Y Ryu J Kim JK Al-Dhafer BAA Shin YH

Aims

The aim of this study was to assess arthritis of the basal joint of the thumb quantitatively using bone single-photon emission CT/CT (SPECT/CT) and evaluate its relationship with patients’ pain and function.

Methods

We retrospectively reviewed 30 patients (53 hands) with symptomatic basal joint arthritis of the thumb between April 2019 and March 2020. Visual analogue scale (VAS) scores for pain, grip strength, and pinch power of both hands and Patient-Rated Wrist/Hand Evaluation (PRWHE) scores were recorded for all patients. Basal joint arthritis was classified according to the modified Eaton-Glickel stage using routine radiographs and the CT scans of SPECT/CT, respectively. The maximum standardized uptake value (SUVmax) from SPECT/CT was measured in the four peritrapezial joints and the highest uptake was used for analysis.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 807 - 810
1 Jul 2020
Oussedik S Zagra L Shin GY D’Apolito R Haddad FS

The transition from shutdown of elective orthopaedic services to the resumption of pre-COVID-19 activity presents many challenges. These include concerns about patient safety, staff safety, and the viability of health economies. Careful planning is necessary to allow patients to benefit from orthopaedic care in a safe and sustainable manner.

Cite this article: Bone Joint J 2020;102-B(7):807–810.


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 556 - 567
1 May 2020
Park JW Lee Y Lee YJ Shin S Kang Y Koo K

Deep gluteal syndrome is an increasingly recognized disease entity, caused by compression of the sciatic or pudendal nerve due to non-discogenic pelvic lesions. It includes the piriformis syndrome, the gemelli-obturator internus syndrome, the ischiofemoral impingement syndrome, and the proximal hamstring syndrome. The concept of the deep gluteal syndrome extends our understanding of posterior hip pain due to nerve entrapment beyond the traditional model of the piriformis syndrome. Nevertheless, there has been terminological confusion and the deep gluteal syndrome has often been undiagnosed or mistaken for other conditions. Careful history-taking, a physical examination including provocation tests, an electrodiagnostic study, and imaging are necessary for an accurate diagnosis.

After excluding spinal lesions, MRI scans of the pelvis are helpful in diagnosing deep gluteal syndrome and identifying pathological conditions entrapping the nerves. It can be conservatively treated with multidisciplinary treatment including rest, the avoidance of provoking activities, medication, injections, and physiotherapy.

Endoscopic or open surgical decompression is recommended in patients with persistent or recurrent symptoms after conservative treatment or in those who may have masses compressing the sciatic nerve.

Many physicians remain unfamiliar with this syndrome and there is a lack of relevant literature. This comprehensive review aims to provide the latest information about the epidemiology, aetiology, pathology, clinical features, diagnosis, and treatment.

Cite this article: Bone Joint J 2020;102-B(5):556–567.


Bone & Joint Research
Vol. 8, Issue 11 | Pages 509 - 517
1 Nov 2019
Kang K Koh Y Park K Choi C Jung M Shin J Kim S

Objectives

The aim of this study was to investigate the biomechanical effect of the anterolateral ligament (ALL), anterior cruciate ligament (ACL), or both ALL and ACL on kinematics under dynamic loading conditions using dynamic simulation subject-specific knee models.

Methods

Five subject-specific musculoskeletal models were validated with computationally predicted muscle activation, electromyography data, and previous experimental data to analyze effects of the ALL and ACL on knee kinematics under gait and squat loading conditions.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 34 - 34
1 Apr 2019
Chang MJ Kang SB Chang CB Yoon C Kim W Shin JY Suh DW Oh JB Kim SJ Choi SH Kim SJ Baek HS
Full Access

The role of unicompartmental knee arthroplasty (UKA) in spontaneous osteonecrosis of the knee (SONK) remains controversial, even though SONK usually involves only medial compartment of the knee joint. We aimed to compare the survival rate and clinical outcomes of UKA in SONK and medial compartment osteoarthritis (MOA) via a meta-analysis of previous studies. MEDLINE database in PubMed, the Embase database, and the Cochrane Library were searched up to January 2018 with keywords related to SONK and UKA. Studies were selected with predetermined inclusion criteria: (1) medial UKA as the primary procedure, (2) reporting implant survival or clinical outcomes of osteonecrosis and osteoarthritis, and (3) follow-up period greater than 1 year. Quality assessment was performed using the risk of bias assessment tool for non-randomised studies (RoBANs). A random effects model was used to estimate the pooled relative risk (RR) and standardised mean difference. The incidence of UKA revision for any reason was significantly higher in SONK than in MOA group (pooled RR = 1.83, p = 0.009). However, the risk of revision due to aseptic loosening and all- cause re-operation was not significantly different between the groups. Moreover, when stratified by the study quality, high quality studies showed similar risk of overall revision in SONK and MOA (p = 0.71). Subgroup analysis revealed worse survival of SONK, mainly related to high failure after uncemented UKA. Clinical outcomes after UKA were similar between SONK and MOA (p = 0.66). Cemented UKA has similar survival and clinical outcomes in SONK and MOA. Prospective studies designed specifically to compare the UKA outcomes in SONK and MOA are necessary.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 77 - 77
1 Apr 2019
Kang SB Chang CB Chang MJ Kim W Shin JY Suh DW Oh JB Kim SJ Choi SH Kim SJ Baek HS
Full Access

Background

Occasionally, patients experience new or increased ankle pain following total knee arthroplasty (TKA). The aims of this study were to determine (1) how the correction of varus malalignment of the lower limb following TKA affected changes in alignment of the ankle and hindfoot, (2) the difference in changes in alignment of the ankle and hindfoot between patients with and without ankle osteoarthritis (OA), and (3) whether the rate of ankle pain and the clinical outcome following TKA differed between the 2 groups.

Methods

We retrospectively reviewed prospectively collected data of 56 patients (99 knees) treated with TKA. Among these cases, concomitant ankle OA was found in 24 ankles. Radiographic parameters of lower-limb, ankle, and hindfoot alignment were measured preoperatively and 2 years postoperatively. In addition, ankle pain and clinical outcome 2 years after TKA were compared between patients with and without ankle OA.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 88 - 88
1 Apr 2019
Kang SB Chang MJ Chang CB Yoon C Kim W Shin JY Suh DW Oh JB Kim SJ Choi SH Kim SJ Baek HS
Full Access

Background

Authors sought to determine the degree of lateral condylar hypoplasia of distal femur was related to degree of valgus malalignment of lower extremity in patients who underwent TKA. Authors also examined the relationships between degree of valgus malalignment and degree of femoral anteversion or tibial torsion.

Methods

This retrospective study included 211 patients (422 lower extremities). Alignment of lower extremity was determined using mechanical tibiofemoral angle (mTFA) measured from standing full-limb AP radiography. mTFA was described positive value when it was valgus. Patients were divided into three groups by mTFA; more than 3 degrees of valgus (valgus group, n = 31), between 3 degrees of valgus to 3 degrees of varus (neutral group, n = 78), and more than 3 degrees of varus (varus group, n = 313). Condylar twisting angle (CTA) was used to measure degree of the lateral femoral condylar hypoplasia. CTA was defined as the angle between clinical transepicondylar axis (TEA) and posterior condylar axis (PCA). Femoral anteversion was measured by two methods. One was the angle formed between the line intersecting femoral neck and the PCA (pFeAV). The other was the angle formed between the line intersecting femoral neck and clinical TEA (tFeAV). Tibial torsion was defined as a degree of torsion of distal tibia relative to proximal tibia. It was determined by the angle formed between the line connecting posterior cortices of proximal tibial condyles and the line connecting the most prominent points of lateral and medial malleolus. Positive values represented relative external rotation. Negative values represented relative internal rotation.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 35 - 35
1 Apr 2019
Suh DW Chang MJ Kang SB Chang CB Yoon C Kim W Shin JY Oh JB Kim SJ Choi SH Kim SJ Baek HS
Full Access

Recently, concerns arose over the medial tibial bone resorption of a novel cobalt-chromium (CoCr) implant. This study aimed to investigate the effects of tibial component material, design, and patient factors on periprosthetic bone resorption and to determine its association with clinical outcomes after total knee arthroplasty (TKA). A total of 462 primary TKAs using five types of implants were included. To evaluate tibial periprosthetic bone resorption, we assessed radiolucent lines (RLL) and change in bone mineral density at the medial tibial condyle (BMDMT). Factors related to bone resorption were assessed using regression analysis. Clinical outcomes were also evaluated with respect to periprosthetic bone resorption. Compared to titanium (Ti) implants, CoCr implants showed a higher incidence of complete RLL (23.1% vs. 7.9% at two years post-TKA) and a greater degree of BMDMT reduction. However, there was no significant difference between the implants made of the same material. Increased medial tibial bone resorption was associated with male sex, osteoporosis, larger preoperative varus deformity, longer follow-up period, and lower body mass index. The periprosthetic bone resorption was not associated with clinical outcomes including changes in range of motion and WOMAC score. Furthermore, no cases warranted additional surgery. Periprosthetic bone resorption was associated with implant material but not with implant design. Moreover, patient factors were related to the medial tibial bone resorption post-TKA. However, the periprosthetic bone resorption was not associated with short-term clinical outcomes. We contend that researchers should incorporate integrative considerations when developing and assessing novel implants.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 76 - 76
1 Apr 2019
Kang SB Chang CB Chang MJ Kim W Shin JY Suh DW Oh JB Kim SJ Choi SH Kim SJ Baek HS
Full Access

Purpose

We sought to determine whether there was a difference in the posterior condylar offset (PCO), posterior condylar offset ratio (PCOR) following total knee arthroplasty (TKA) with anterior referencing (AR) or posterior referencing (PR) systems. We also assessed whether the PCO and PCOR changes, as well as patient factors were related to range of motion (ROM) in each referencing system. In addition, we examined whether the improvements in clinical outcomes differed between the two referencing systems.

Methods

This retrospective study included 130 consecutive patients (184 knees) with osteoarthritis who underwent primary posterior cruciate ligament (PCL)-substituting fixed-bearing TKA. All patients were categorized into the AR or PR group according to the referencing system used. Radiographic parameters, including PCO and PCOR, were measured using true lateral radiographs. The difference between preoperative and postoperative PCO and PCOR values were calculated. Clinical outcomes including ROM and Western Ontario and McMaster University (WOMAC) scores were evaluated preoperatively and at 2 years after TKA. The PCO, PCOR values, and clinical outcomes were compared between the two groups.

Furthermore, multiple linear regression analysis was performed to determine the factors related to postoperative ROM in each referencing system.


Bone & Joint Research
Vol. 7, Issue 5 | Pages 357 - 361
1 May 2018
Shin T Lim D Kim YS Kim SC Jo WL Lim YW

Objectives

Laser-engineered net shaping (LENS) of coated surfaces can overcome the limitations of conventional coating technologies. We compared the in vitro biological response with a titanium plasma spray (TPS)-coated titanium alloy (Ti6Al4V) surface with that of a Ti6Al4V surface coated with titanium using direct metal fabrication (DMF) with 3D printing technologies.

Methods

The in vitro ability of human osteoblasts to adhere to TPS-coated Ti6Al4V was compared with DMF-coating. Scanning electron microscopy (SEM) was used to assess the structure and morphology of the surfaces. Biological and morphological responses to human osteoblast cell lines were then examined by measuring cell proliferation, alkaline phosphatase activity, actin filaments, and RUNX2 gene expression.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 10 - 10
1 Apr 2018
Shin Y Yoon J
Full Access

Purpose

Many studies have found associations between laboratory biomarkers and periprosthetic joint infection (PJI), but it remains unclear whether these biomarkers are clinically useful in ruling out PJI. This meta-analysis compared the performance of interleukin-6 (IL-6) versus procalcitonin (PCT) for the diagnosis of PJI.

Materials and Methods

In this meta-analysis, we reviewed studies that evaluated IL-6 or/and PCT as a diagnostic biomarker for PJI and provided sufficient data to permit sensitivity and specificity analyses for each test. The major databases MEDLINE, EMBASE, the Cochrane Library, Web of Science, and SCOPUS were searched for appropriate studies from the earliest available date of indexing through February 28, 2017. No restrictions were placed on language of publication.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 44 - 44
1 Apr 2018
Shin J Song M Yoon C Chang M Chang C Kang S
Full Access

Background

As the number of primary or revision TKA with stem extension cases are growing simultaneously, the number of periprosthetic fracture in these cases has also increased accordingly. However, there have been few reports on the classification and treatment of periprosthetic fracture following stemmed TKA and lack of information about the treatment outcome. The purposes of this study were 1) to demonstrate classification and management of periprosthetic fractures after stemmed TKA and 2) to report treatment outcome after the periprosthetic fractures.

Materials and Methods

This retrospective study included 17 knees (15 patients) with an average age of 69.7 years. All cases were revision TKA cases, and there were 13 female and 2 male patients. The patients were treated nonoperatively or underwent operation by orthopedic principle. The period of union was evaluated by confirming the formation of callus crossing fragments in radiographs. We reviewed the complications and functional outcomes after treatment of periprosthetic fracture following revision TKA by assessing FF, FC and scoring WOMAC and KSS.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 45 - 45
1 Apr 2018
Yoon C Chang C Chang M Shin J Song M Kang S
Full Access

Background

Joint line, patellar height and posterior condylar offset (PCO) are related to functional outcome such as stability and range of motion after revision total knee arthroplasty (TKA). The purpose of this study was (1) to determine whether revision TKA can restore the joint line, patella height and condylar offset after surgery, and (2) to assess factors associated with failed restoration.

Materials and Methods

We retrospectively reviewed 27 consecutive patients who underwent revision TKA. Among 27 patients, 11 patients had two-stage revision TKA due to periprosthetic joint infection while 14 patients underwent revision TKA due to aseptic loosening. In addition, there were 2 patients who had traumatic event causing a periprosthetic fracture which led to revision TKA. The joint line was measured using the distance from the adductor tubercle of the femur to the most distal portion of the medial femoral component on knee anterior-posterior radiographs. Patella height was assessed using the Caton-Deschamps method. In addition, PCO were measured relative to the tangent of the posterior cortex of the femur using knee lateral radiograph. All parameters were compared between pre- and postoperative radiographs after revision TKA.


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 197 - 204
1 Feb 2018
Gaspar MP Pham PP Pankiw CD Jacoby SM Shin EK Osterman AL Kane PM

Aims

The aims of this study were to compare the mid-term outcomes of patients with late-stage arthritis of the wrist treated with proximal row carpectomy (PRC) and dorsal capsular interposition (DCI) arthroplasty with a matched cohort treated with routine PRC alone.

Patients and Methods

A total of 25 arthritic wrists (24 patients) with pre-existing degenerative changes of the proximal capitate and/or the lunate fossa of the radius were treated with PRC + DCI over a ten-year period. This group of patients were matched 1:2 with a group of 50 wrists (48 patients) without degenerative changes in the capitate or lunate fossa that were treated with a routine PRC alone during the same period. The mean age of the patients at the time of surgery was 56.8 years (25 to 81), and the demographics and baseline range of movement of the wrist, grip strength, Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH) score, and Patient-Rated Wrist Evaluation (PRWE) score were similar in both groups.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 69 - 69
1 Jan 2018
Yoon T Park K Cho K Shin Y Yang H
Full Access

Osteonecrosis of the femoral head (ONFH) is a painful and disabling condition, which most commonly involves the hips of young patients. But despite of the high incidence, treatment is still has not been definitely identified. We performed a modified muscle pedicle bone graft (MPBG) technique using anterior one-third of gluteus medius (GM) attached to the greater trochanter (GT) in ONFH. The purpose of this study was to evaluate the effectiveness of our technique on ONFH in ARCO stage II and III patients.

Between June 2007 and March 2015, 24 hips were treated by our technique, who were able to follow up at least 2 years. The group was consisted of 15 men and 8 women, mean age of 36 years at the time of surgery. Mean follow-up was 5 years.

Twenty of 24 hips hips had no progression of necrotic lesions. The postoperative scintigrams showed increased blood flow in the 3 month follow up evaluation. But 4 hips underwent THA at the mean follow-up of 6 years after the surgery, and considered as “failure”. Excluding the 4 failed cases, the mean Harris hip score was improved from 54 points to 85 points at the last follow up.

Through our new technique, we showed 83% of survival rate by average of 5 year follow up. And compared to other reports, our technique showed relatively good survival rate and clinical outcomes. Therefore, we suggest this modified technique as one of promising treatment of choices for young patients with ARCO stage II or III ONFH.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 148 - 148
1 Mar 2017
Shin Y Lee D
Full Access

Purpose

This meta-analysis was designed to compare the effectiveness and safety of intravenous (IV) versus topical administration of tranexamic acid (TXA) in patients undergoing primary total knee arthroplasty (TKA) by evaluating the need for allogenic blood transfusion, incidence of postoperative complications, volume of postoperative blood loss, and change in hemoglobin levels.

Materials and Methods

Studies were included in this meta-analysis if they assessed the allogenic blood transfusion rate, postoperative complications including pulmonary thromboembolism (PTE) or deep vein thrombosis (DVT), volume of postoperative blood loss via drainage, estimated blood loss, total blood loss, and change in hemoglobin before and after surgery in primary TKA with TXA administered through both the intravenous (IV) and topical routes.[Fig. 1]


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 28 - 28
1 Mar 2017
Shin T Park S Kang K Kwon S Lim Y Moon Y Lim D
Full Access

Introduction

Recently, the combination of press-fit acetabular cup with ceramic articulation is a widely used for implanting cementless acetabular components and has been shown to provide good initial stability. However, these methods may lead to elevating stresses, changing in the bearing geometries, and increasing wear due to deformation of the cup and insert. In addition, there is a potential for failure of ceramic inserts when a large ball head was used because it should be assembled with shallow thickness of the acetabular cup. For risk reduction of it, we applied direct metal tooling (DMT) based on 3D printing for porous coating on the cup. Due to its capability of mechanical strength, DMT coated cup could be feasible to provide better stability than conventional coating. Therefore, we constructed laboratory models for deformation test simulating an press-fit situation with large ceramic ball head to evaluate stability of the DMT coated cup compared with conventional coated cup.

Materials and Methods

The deformation test was performed according to the test setup described by Z. M. Jin et al. The under reaming of the cavity in a two-point pinching cavity models of polyurethane (PU) foam block (SAWBONES, Pacific Research Laboratories, USA) with a grade 30 were constructed. Titanium plasma spray (TPS) and direct metal tooling (DMT) coated acetabular cups (BENCOX Mirabo and Z Mirabo Cup, Corentec Co. Ltd., KOREA) with a 52 mm size (n=3, respectively) were used for the test. These cups were implanted into the PU foam blocks, and followed by impaction of the inserts (BIOLOX delta, Ceramtec, GE) with a 36/44 size (n=6) into the acetabupar cups as shown in Fig. 1. Roundness and inner diameter of the acetabular cups and inserts were measured using a coordinate measuring machine (BHN 305, Mitutoyo Neuss, GE) in three levels; E2, E3, and E4 (3, 5, and 7 mm below the front face, respectively). Also, these parameters of the acetabular cup were measured in two level; E1 and E5 (5 and 11 mm below the front face) as shown in Fig. 2. Changes in roundness and inner diameter of the cup and insert were measured to evaluate deformation in relation to porous coating on the acetabular cups.


Purpose

To promote rapid bone healing, an adequate stable fixation implant with a percutaneous reduction instrument should be used for Vancouver type B1 or C fractures. The objective of this study was to describe radiographic and clinical outcomes of patients with periprosthetic fracture (PPF) around a stable femoral stem, treated with a distal femoral locking plate alone or with a cerclage cable.

Materials and Methods

A total of 21 patients with PPF amenable to either a reverse distal femoral locking plate (LCP DF®) alone or with a cerclage cable, with a mean age of 75.7 years, were included. In these patients, 10 fractures were treated with a reverse LCP DF® alone and were classified as group I, and 11 additionally received a cerclage cable and were classified as group II.[Fig.1]


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 134 - 138
1 Jan 2017
Houdek MT Bayne CO Bishop AT Shin AY

Aims

Free vascularised fibular grafting has been used for the treatment of large bony defects for more than 40 years. However, there is little information about the risk factors for failure and whether newer locking techniques of fixation improve the rates of union. The purpose of this study was to compare the rates of union of free fibular grafts fixed with locking and traditional techniques, and to quantify the risk factors for nonunion and failure.

Patients and Methods

A retrospective review involved 134 consecutive procedures over a period of 20 years. Of these, 25 were excluded leaving 109 patients in the study. There were 66 men and 43 women, with a mean age of 33 years (5 to 78). Most (62) were performed for oncological indications, and the most common site (52) was the lower limb. Rate of union was estimated using the Kaplan-Meier method and risk factors for nonunion were assessed using Cox regression. All patients were followed up for at least one year.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 35 - 35
1 May 2016
Shin T Kang K Park S Kwon S Lim Y Lim D
Full Access

Introduction

Cementless arthroplasty has been widely used for younger patients with osteoarthritis and other joint pathology. Cementless arthroplasty will be required to porous surface which is to similar to the trabecular bone for bone ingrowth. Titanium Plasma Spray (TPS) has been worldwide used for the porous coating method on arthroplasty. However, TPS coating is limited that would not to establish optimal porosity for bone ingrowth due to arbitary position of melted powder by plasma gas on substrate. Therefore, it is reported coating detached from its substrate (i.e. arthroplasty) is induced implant loosening. Thus, a novel Laser-aided Direct Metal Tooling (DMT) based on Additive Manufacturing (AM) was developed to overcome these limitations. In this study, we were done to assess stereological analysis, static tensile, shear, abrasion test, and physical analysis for evaluation of the efficacy of DMT which was newly-developed coating technology. Then, mechanical characteristics of DMT coating were compared to commercial TPS coating's.

Materials and Methods

First, porosity of the DMT coating was evaluated using Microphotography and Scanning Electron Microscopy (SEM), as described in Figure 1. Static tensile and shear test for assessment of mechanical characteristic in relation to the DMT and TPS coating specimens were conducted on the basis of ASTM F1147 and F1044 using universal testing machine (Endolab®, Servohydraulic Test Frame, DE). Maximum tensile strength and maximum shear strength were evaluated for each specimen (n=5). Abrasion test was performed based on ASTM F1978 using Taber® Rotary Platform Abraser Model 5135 (TABER®Industries, USA). Abrasion losses for each specimen (n=6) were measured at 2, 5, 10, and 100 cycles, respectively.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 34 - 34
1 May 2016
Shin Y Lee J Han S
Full Access

A matched comparison was made between femoral neck-preserving short, tapered stems (n = 50) and conventional length femoral stems (n = 50) in cementless total hip arthroplasty between January 2008 and January 2012. Patients were matched for age, sex, body mass index, height, surgical approach, and surgeon. In group A, mean preoperative HHS and WOMAC scores of 55.0 and 53.0, respectively, improved to mean postoperative scores of 98.6 and 3.3, respectively, at an average follow–up of 37.2 months. In group B, mean preoperative HHS and WOMAC scores of 53.0 and 49.5, respectively, improved to mean postoperative scores 97.8 and 4.4, respectively, at an average follow–up of 35.3 months. In addition, no significant differences in mean postoperative HHS (P = 0.168) or WOMAC scores (P = 0.158) were observed between the two groups according to the independent sample t-test. Table 1 shows two stems (4%) located in valgus (greater than 5° from neutral). The mean preoperative and postoperative HHS and WOMAC scores were similar to those of stems neutrally located in group A. All group A stems displayed bone bridging and endosteal spot welds distributed in Gruen zones 2 and 6 as evidence of bony ingrowth with no radiolucencies (Fig. 1). Two patients in group B had the slight decrease in bone density, mostly in Gruen zone 1 and 7. No radiographic evidence of osteolytic lesions, cortical hypertrophy, or acetabular fractures was detected in either group. Furthermore, no patient required revision surgery for aseptic loosening. The chi–square (Fisher's exact) test showed no significant difference between the two groups with respect to patient complications (Table 2). One patient in group A with a CCD angle of 135° had subsidence (greater than 2 mm, P =0.313) that displayed bony ingrowth with no further progression of subsidence at final follow-up. An intraoperative minor femur neck fracture (P =1.00) occurred in two patients (one in group A and one in group B). These patients were treated by cerclage wires without further incident. Three patients (two in group A: valgus and a CCD angle 135°, and one in group B: varus) had malalignment (P = 0.554) that was not associated with loosening. One patient in group A with a CCD angle of 135° had greater than 1 cm leg length discrepancy (shortening, P = 0.313). Two patients in group B had thigh pain (P = 0.151) that disappeared after a few months. Three patients (one in group A and two in group B) had heterotopic ossifications (P = 0.554) that were categorized as Brooker class I in two patients and class II in one patient without limiting their activities. In conclusion, no significant differences in the clinical and radiographic outcomes as well as component-specific complications were observed between the two groups, showing satisfactory performance at the 5-year follow-up. Group A had a higher incidence of malalignment and subsidence and a lower incidence of thigh pain and proximal bone resorption than group B.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 96 - 96
1 May 2016
Kim K Lee S Kim J Shin W
Full Access

Background

In this study, we investigated the long-term clinical results and survivorship of minimally invasive unicompartmental knee arthroplasty (UKA) by collecting cases that have been implanted for >10 years ago.

Methods

Medial UKA on 180 cases in 142 patients was performed over a period of 1 year after the first introduction of minimally invasive UKA from January 2002 to December 2002. Among these, 166 cases in 128 patients who underwent Oxford phase 3 medial UKA using the minimally invasive surgery, with the exclusion of 14 cases including 10 cases of follow-up loss and 4 cases of death, were selected as the subject. The mean age of the patients at the time of surgery was 61 years, and the duration of the follow-up was minimum 10 years. All the preoperative diagnosis was osteoarthritis of the knee joint. Clinical and radiographic assessments were measured by the Knee Society clinical rating system, and the survival analysis was confirmed by the Kaplan–Meier method with 95% confidence interval (CI).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 33 - 33
1 May 2016
Shin Y Lee J Han S
Full Access

We prospectively analyzed 83 patients who underwent ceramic-on-ceramic THA using preassembled (n = 22) or modular acetabular components (n = 61) between June 2010 and June 2012. No radiographic evidence of progressive radiolucency, osteolytic lesions, acetabular fractures, or component migration was detected in either group. Furthermore, no patient required revision surgery for instability or ceramic breakage. Table 1 shows the mean postoperative HHS, WOMAC score, and acetabular component inclination and anteversion in groups A and B. No significant differences in mean postoperative HHS (P < 0.056), WOMAC score (P < 0.258), acetabular component inclination (P < 0.827), or anteversion (P < 0.549) were observed between the two groups according to the independent sample t-test. However, the chi-square (Fisher's exact) test showed a significant difference between the two groups with respect to the gender of the patients (P < 0.001, Table 2). These findings indicate that half of the women had smaller acetabular diameters accommodating a cup size of only 48–50-mm. Thus a preassembled ceramic liner is a very good option for women with a small acetabulum, which could permit the use of a larger femoral head (36-mm) with thin-walled acetabular components. In contrast, the component-specific complications between the two groups were quite similar. One patient (group B) had transient squeaking that disappeared after a few months. One patient (group B) had a mild limp caused by abductor muscle weakness, and one patient (group B) had a superficial wound infection that was treated with local debridement and antibiotics. Early dislocation (P < 0.488) occurred in three patients (one in group A and two in group B). Two patients (one in group A and one in group B) reported postoperative falling events at their bedside. The other in group B was a female with rheumatoid arthritis, which can lead to a much higher risk of dislocation due to soft tissue laxity around the hip joint. All of these patients were treated by closed reduction without further incident. Three patients (one in group A and two in group B) had mild iliopsoas pain (P < 0.488) that was not associated with loosening; however, the pain did not limit their activities (Table 3). In conclusion, we found no significant differences in the mean postoperative radiographic or functional outcomes or complications between the two groups, showing satisfactory performance at the 2 year follow up. Only the gender of the patient was significantly different between the two goups, demonstrating that a larger number of women had smaller acetabular diameters accommodating a cup size of only 48–50-mm. Although a preassembled cup with a 36-mm ceramic liner has proven safety in the short term, future research should focus on its long-term risks.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 82 - 82
1 Jan 2016
Choi CH Chung KS Lee JK Shin TY
Full Access

Introduction

We investigated the incidence of venous thromboembolism (VTE) and pulmonary embolism (PE) after total knee arthroplasty (TKA) and assessed the efficacy and complications of three different chemical prophylactic regimens.

Materials and Methods

From May, 2011 to November 2013, 268 patients, 330 knees were randomly allocated to three groups, low molecular weight heparin (LMWH) 5000IU for 2 days followed by aspirin 100mg for 5 days (Group HA, 110 knees), rivaroxaban 10mg for 7 days (Group X7, 110 knees), or for 10 days (Group X10, 110 knees) postoperatively. Intermittent pneumatic compression device was applied on all patients. The multidetector row computed tomography (MDCT) was done at postoperative 10 days to evaluate VTE (PE & DVT separately), and MDCT was rechecked to evaluate the changes of VTE at postoperative 3 months in VTE patients. Additionally, major and minor bleeding complications, amounts of bleeding, and bruise around wound were checked.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 12 - 12
1 Jan 2016
Song IS Shin SY
Full Access

Purpose

We may consider total knee arthroplasty on one knee and unicompartmental knee arthroplasty on another knee when the patient has different grade osteoarthritis on one knee and opposite knee. Both total knee and unicompartmental knee arthroplasty had been reported as excellent clinical results, but there can be different results and different preference if the same patient undergo operation of simulataneous total knee and unicompartmental knee. We performed total and unicompartmental knee arthroplasty and pretend to report results of the clinical and radiological results and rationale of the operation.

Materials and Methods

From Marth 2007 to February 2014, 23 patients, 46 knees that underwent total knee arthroplasty and unicompartmental knee arthroplasty on knees with different osteoarthritis grade in same person enrolled in this study(Fig. 1). The mean age was 64.4 years old(range:55–75) and mean follow-up period was 25.1 months(range:13–72).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 11 - 11
1 Jan 2016
Song IS Shin SY
Full Access

Purpose

To evaluate the results of reverse total shoulder arthroplasty for complicated proximal humerus fractures in old ages.

Materials and Methods

We retrospectively evaluated 13 cases who underwent reverse total shoulder arthroplasty for proximal humerus fracture, fracture-dislocation and nonunions of the fractures. Mean age was 77(68–87)years old and mean follow-up period was 15.2(12–26)months. four part fractures of proximal humerus in 7 cases, fracture-dislocation in 3 cases, locked dislocation with greater tuberosity in 2 cases, nonunion with defiency of rotator cuff in 1 case were included. We evaluated mean ASES, mean UCLA, mean KSS, mean SST and mean range of motion(ROM).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 10 - 10
1 Jan 2016
Song IS Shin SY
Full Access

Background

The aim of this study was to evaluate causes and results of revision surgery in unstable total knee arthroplasties.

Methods

We retrospectively reviewed 24 knees that underwent a revision arthroplasty for unstable total knee arthroplasty. The average follow-up period was 33.8 months. We classified the instability and analyzed the treatment according to its cases. Stress radiographs, postoperative component position and joint level were measured. Clinical outcomes were assessed using the score and range of motion of the Hospital for Special Surgery (HSS).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 13 - 13
1 Jan 2016
Song IS Shin SY
Full Access

Purpose

The purpose of this study is toevaluate the clinical and radiologic results after high flexiontotal knee arthroplasty, Lospa®(Corentec Inc.) with 10mm cutting of posterior femoral condyle and LPS-Flex®(Zimmer Inc.) with 12.5mm cutting of posterior femoral condyle.(Fig. 1)

Materials and Methods

We prospectively compared 205 knees in 128 patients who underwent arthroplasty usingLospa®(groupA) and 63 knees in 48 patients who underwentarthroplasty using NexGen LPS-Flex®(group B) from September 2010 to March 2012 at Department of Orthopaedic Surgery, Sun General Hospital (Daejeon, Korea). Mean follow-up period was 33 months(24–42) in group A and 33months(23–45) in group B, and mean age was 69.5 in group A, 70.4 in group B. The radiologic analysis included the change of mechanical axis deviation and femoro-tibial angle, implant position (α,β,γ,δ)(Fig 2). The clinical results were evaluated according to Hospital for special surgery (HSS), Knee society score (KSS), and range of motion.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 611 - 616
1 May 2015
Shin WC Lee SM Lee KW Cho HJ Lee JS Suh KT

There is no single standardised method of measuring the orientation of the acetabular component on plain radiographs after total hip arthroplasty. We assessed the reliability and accuracy of three methods of assessing anteversion of the acetabular component for 551 THAs using the PolyWare software and the methods of Liaw et al, and of Woo and Morrey. All measurements of the three methods had excellent intra- and inter-observer reliability. The values of the PolyWare software, which determines version of the acetabular component by edge detection were regarded as the reference standard. Although the PolyWare software and the method of Liaw et al were similarly precise, the method of Woo and Morrey was significantly less accurate (p < 0.001). The method of Liaw et al seemed to be more accurate than that of Woo and Morrey when compared with the measurements using the PolyWare software. If the qualified lateral radiograph was selected, anteversion measured using the method of Woo and Morrey was considered to be relatively reliable.

Cite this article: Bone Joint J 2015; 97-B:611–16.


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 743 - 751
1 Jun 2014
Shin YS Ro KH Jeon JH Lee DH

We used immediate post-operative in vivo three-dimensional computed tomography to compare graft bending angles and femoral tunnel lengths in 155 patients who had undergone single-bundle reconstruction of the anterior cruciate ligament using the transtibial (n = 37), anteromedial portal (n = 72) and outside-in (n = 46) techniques.

The bending angles in the sagittal and axial planes were significantly greater but the coronal-bending angle was significantly less in the transtibial group than in the anteromedial portal and outside-in groups (p < 0.001 each). The mean length of the femoral tunnel in all three planes was significantly greater in the transtibial group than the anteromedial portal and outside-in groups (p < 0.001 each), but all mean tunnel lengths in the three groups exceeded 30 mm. The only significant difference was the coronal graft- bending angle in the anteromedial portal and outside-in groups (23.5° vs 29.8°, p = 0.012).

Compared with the transtibial technique, the anteromedial portal and outside-in techniques may reduce the graft-bending stress at the opening of the femoral tunnel. Despite the femoral tunnel length being shorter in the anteromedial portal and outside-in techniques than in the transtibial technique, a femoral tunnel length of more than 30 mm in the anteromedial portal and outside-in techniques may be sufficient for the graft to heal.

Cite this article: Bone Joint J 2014;96-B:743–51.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_24 | Pages 4 - 4
1 May 2013
Gardner ROE Sharma OP Feng L Shin M Howard A Kelley S Wedge JH
Full Access

Aim

To compare the rate and severity of avascular necrosis following medial open and closed reduction in developmental hip dysplasia and the resulting influence on femoral and acetabular development.

Method

The radiographs and hospital records of 118 patients with dislocation of the hip were reviewed. 57 patients (66 hips) underwent medial open reduction and 61 patients (75 hips) underwent closed reduction. Mean follow-up was 10.9 years (5 years to 17.4 years). Avascular necrosis (AVN) was recorded according to the Bucholz and Ogden classification. The acetabular index was measured pre-operatively, at 1 and 4 years following surgery. The final radiograph was assigned a Severin grade. Sharp and centre-edge angles were recorded at final follow-up. A Severin grade I or II was considered a satisfactory result and a grade III to V an unsatisfactory result. Initial non-operative measures, such as Pavlik harness treatment and traction were documented. Additional surgical interventions were noted.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 558 - 562
1 Apr 2013
Kim SM Park JM Shin SH Seo SW

It is important to be able to identify patients with an increased risk of venous thromboembolism (VTE) in order to minimise the risk of an event. We investigated the incidence and risk factors for post-operative VTE in 168 consecutive patients with a malignancy of the lower limb. The period of study included ten months before and 12 months after the introduction of chemical thromboprophylaxis. All data about the potential risk factors were identified and classified into three groups (patient-, surgery- and tumour-related). The outcome measure was a thromboembolic event within 90 days of surgery.

Of the 168 patients, eight (4.8%) had a confirmed symptomatic deep-vein thrombosis and one (0.6%) a fatal pulmonary embolism. Of the 28 variables tested, age > 60 years, higher American Society of Anesthesiologists grade and metastatic tumour were independent risk factors for VTE. The overall rate of symptomatic VTE was not significantly different between patients who received chemical thromboprophylaxis and those who did not. Knowledge of these risk factors may be of value in improving the surgical outcome of patients with a malignancy of the lower limb.

Cite this article: Bone Joint J 2013;95-B:558–62.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 212 - 212
1 Mar 2013
Kang J Moon KH Kwon D Shin SH Rhu DJ Park YS
Full Access

Introduction

The natural history of osteonecrosis of the femoral head (ONFH) is not cleanly understood, but most of them progresse to the joint destruction and requires total hip replacement arthroplasty. There are several head preserving procedure, but no single therapeutic method proved to be effective in preventing progression of the disease. The possibility has been raised that implantation of bone marrow containing osteogenic precursors may be effective in the treatment of this disease. However, there are no long-term follow-up results of cell therapy for ONFH. AS far as we know, there are no reports about bone graft and cell therapy for ONFH. Therefore, we performed a prospective clinical and radiological evaluation on ONFH treated with core decompression combined with autoiliac bone graft and an implantation of autologous bone marrow cells as a therapeutic method of ONFH.

Materials and Methods

Sixty-one hips in 52 patients with ONFH were included in this study. The average follow-up of the patients was 68 (60∼88) months. The necrotic lesions were classified according to their size and location, and we compared the results.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 211 - 211
1 Mar 2013
Kang J Moon KH Kwon D Shin SH Rhu DJ
Full Access

Purpose

This study analyzed the long-term results of cementless total hip arthroplasty using an extensively porous coated stem in patients younger than 45 years old.

Materials and Methods

The clinical and radiographic results of 45 hips from 38 patients who underwent cementless total hip replacement arthroplasty with an AML prosthesis were reviewed retrospectively. The average follow-up was 12 years (range, 10–15 years).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 517 - 522
1 Apr 2012
Jeon I Chun J Lee C Yoon J Kim P An K Morrey BF Shin H

The zona conoidea comprises the area of the lateral trochlear ridge of the humerus. The purpose of this study is to reintroduce this term ‘zona conoidea’ to the discussion of the human elbow and to investigate its significance in the development of osteoarthritis of the elbow.

The upper extremities of 12 cadavers were prepared. With the forearm in neutral, pronation and supination, the distance between the bevel of the radial head and zona conoidea was inspected. A total of 12 healthy volunteers had a CT scan. The distance between the zona conoidea and the bevelled rim of the radial head was measured in these positions.

In the anatomical specimens, early osteo-arthritic changes were identified in the posteromedial bevelled rim of the radial head, and the corresponding zona conoidea in supination. Measurement in the CT study showed that in full supination, the distance between the bevel of the radial head and the zona conoidea was at a minimum.

This study suggests that the significant contact between the bevel of the radial head and the zona conoidea in supination is associated with the initiation of osteoarthritis of the elbow in this area.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 93 - 97
1 Jan 2012
Lee JH Lee J Park JW Shin YH

In patients with osteoporosis there is always a strong possibility that pedicle screws will loosen. This makes it difficult to select the appropriate osteoporotic patient for a spinal fusion. The purpose of this study was to determine the correlation between bone mineral density (BMD) and the magnitude of torque required to insert a pedicle screw. To accomplish this, 181 patients with degenerative disease of the lumbar spine were studied prospectively. Each underwent dual-energy x-ray absorptiometry (DEXA) and intra-operative measurement of the torque required to insert each pedicle screw. The levels of torque generated in patients with osteoporosis and osteopenia were significantly lower than those achieved in normal patients. Positive correlations were observed between BMD and T-value at the instrumented lumbar vertebrae, mean BMD and mean T-value of the lumbar vertebrae, and mean BMD and mean T-value of the proximal femur. The predictive torque (Nm) generated during pedicle screw insertion was [-0.127 + 1.62 × (BMD at the corresponding lumbar vertebrae)], as measured by linear regression analysis. The positive correlation between BMD and the maximum torque required to insert a pedicle screw suggests that pre-operative assessment of BMD may be useful in determining the ultimate strength of fixation of a device, as well as the number of levels that need to be fixed with pedicle screws in patients who are suspected of having osteoporosis.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 465 - 465
1 Nov 2011
Kobayashi K Sakamoto M Kimura T Shin K Tanabe Y Omori G Koga Y
Full Access

In order to understand the actual weight-bearing condition of lower extremity, the three dimensional (3D) mechanical axis of lower limb was compared with the loading direction of ground reaction force (GRF) in standing posture.

Three normal subjects (male, 23–39 yo) participated in the study. A bi-planar radiograph system with a rotation table was used to take frontal and oblique images of entire lower limb. Each subject’s lower limb was CT scanned to create 3D digital models of the femur and tibia. The contours of the femur and tibia in both radiographs and the projected outlines of the 3D digital femur and tibia models were matched to recover six-degree of freedom parameters of each bone. The 3D mechanical axis was a line drawn from the centre of the femoral head to the centre of the ankle. A surface proximity map was created between the distal femoral articular surface and the proximal tibial articular surface. A force plate was positioned on the rotation table to measure GRF during biplanar X-ray exposure. Each subject put one’s foot measured on the force plate and the other on the shield. Bi-planar radiographs were taken in double-limb standing, double-limb standing with toe up in the leg measured, and single-limb standing. The anterior and medical deviations of the loading direction of GRF from the 3D mechanical axis were determined at the proximal tibia and normalized by the joint width in anteroposterior direction and by the joint width in lateral direction.

For all subjects the passing points of the 3D mechanical axis at the proximal tibia were almost in the middle of the joint width in lateral direction. Compared to the 3D mechanical axis, the loading direction of GRF passed through the anterior region in double-limb standing and single-limb standing, and anteromedial region in single-limb standing. The normalized medial deviation was significantly greater in singlelimb standing than in double-limb standing (p=0.023). The separation distance tended to decrease in the medial compartment in single-limb standing, and to increase in toe up in the entire region.

Deviation of the loading direction of GRF from the 3D mechanical axis at the proximal tibia varied among standing postures, relating to the change in weightbearing condition as indicated in the separation distance map. These results provide the mechanical perspective related to the causes and progression of knee OA and may contribute to the improvement of surgical treatments such as arthroplasty and osteotomy.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 423 - 423
1 Nov 2011
Bae DK Yoon KH Song SJ Shin M Noh J Park M Cho H Choi I
Full Access

In conventional high tibial osteotomy it is difficult to obtain the ideal correction angle consistently and there is high variability of postoperative alignment. We assessed the reliability, accuracy and variability of closed wedge high tibial osteotomy using computer-assisted surgery compared to the conventional technique. Fifty closed wedge HTO procedures were performed and analysed between July 2005 and July 2006, using the CT-free navigation system(Vector Vision® version 1.1, Brain-LAB, Heimstetten, Germany) for medial compartment osteoarthritis of the knee and fifty knee operations using conventional closed-wedge HTO, performed between 1994 and 2006, were retrospectively reviewed as a control group. The mean age was 59.4 years for the navigation group and 60.7 years for the conventional group. In the navigation group, the mean mechanical axis (MA) before osteotomy was varus 8.2°, and the mean MA after the fixation was valgus 3.6°. On the radiographs, the mean preoperative MA was varus 7.3°, and the mean postoperative MA was valgus 2.1°. In the conventional group, the mean MA was varus 10.6° preoperatively and valgus 0.1° postoperatively via the radiograph. The mean preoperative posterior slope angle (PSA) was 11.0°, which decreased to 9.0° in the navigation group. The mean preoperative PSA was 10.4°, which decreased to 6.4° in the conventional group(p = 0.000). There was a positive correlation between measured data taken under navigation and by radiographs(r > 0.3, P < 0.05). The mean correction angle was significantly more accurate in the navigation group(p < 0.002). The variability of the correction was significantly lower in the navigation group (2.3° versus 3.7°, p = 0.012), and the distribution of MA was also narrower in the navigated group.

We concluded that navigation provides reliable real-time intraoperative information and may increase accuracy, and improve the precision of closed-wedge HTO.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1400 - 1404
1 Oct 2011
Lee C Chung SS Shin S Park S Lee H Kang K

We examined the differences in post-operative functional disability and patient satisfaction between 56 patients who underwent a lumbar fusion at three or more levels for degenerative disease (group I) and 69 patients, matched by age and gender, who had undergone a one or two level fusion (group II). Their mean age was 66 years (49 to 84) and the mean follow-up was 43 months (24 to 65).

The mean pre-operative Oswestry Disability Index (ODI) and visual analogue scale (VAS) for back and leg pain, and the mean post-operative VAS were similar in both groups (p >  0.05), but post-operatively the improvement in ODI was significantly less in group I (40.6%) than in group II (49.5%) (p < 0.001). Of the ten ODI items, patients in group I showed significant problems with lifting, sitting, standing, and travelling (p < 0.05). The most significant differences in the post-operative ODI were observed between patients who had undergone fusion at four or more levels and those who had undergone fusion at less than four levels (p = 0.005). The proportion of patients who were satisfied with their operations was similar in groups I and II (72.7% and 77.0%, respectively) (p = 0.668). The mean number of fused levels was associated with the post-operative ODI (r = 0.266, p = 0.003), but not with the post-operative VAS or satisfaction grade (p > 0.05). Post-operative functional disability was more severe in those with a long-level lumbar fusion, particularly at four or more levels, but patient satisfaction remained similar for those with both long- and short-level fusions.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 73 - 73
1 Mar 2010
Shin S Zeni A Crichlow R Maar D Kaehr D Stone M Vijay P
Full Access

PURPOSE: To determine the capability of fellowship trained Orthopaedic Trauma surgeons to predict union or non-union of femoral and tibial shaft fractures.

METHODS: A series of 50 patients with femur or tibia shaft fractures were evaluated. Patients were prospectively followed at 2,6,12, and 18 weeks after surgical intervention. At each interval surgeons evaluated factors related to fracture healing on AP and lateral radiographs and predicted the probability of union on a visual analog scale. Union was defined as radiographic evidence of healing three of four cortices, no tenderness with palpation of the fracture site, and full weight bearing without the use of assistive devices.

RESULTS: Eight patients missed initial visits or were lost to follow-up, making for a total of 42 patients that were included in the results. Average patient age was 31 years. Eighty-one percent of the patients went onto union (N=34) and 19% went onto nonunion (N=8). Early clinical prediction for nonunion at 2 weeks had a sensitivity of 50%, a specificity of 91%, a positive predictive value (PPV) of 57%, and a negative predictive value (NPV) of 89%. At 6 weeks, there was a sensitivity of 75%, a specificity of 100%, a PPV of 100%, and a NPV of 94%. One patient treated with intramedullary nailing was 15 years old and despite minimal callous formation the physician incorrectly predicted future union given the young age. The other patient had a severely comminuted femur fracture and required a quad cane to ambulate and should perhaps have been predicted to go onto nonunion. At 12 and 18 weeks, sensitivity, specificity, PPV, and NPV were both 100%.

CONCLUSIONS: Fellowship trained orthopaedic trauma surgeons at 6-week follow-up can predict union with a sensitivity of 75% and specificity of 100% and a PPV of 100%. Early clinical prediction at 6 weeks can be used to provide the patient with a secondary intervention such as a bone graft or bone stimulator and avoid months of delay.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 123 - 123
1 Mar 2010
Bae DK Song SJ Yoon KH Shin SM
Full Access

In the anatomical studies for Caucasian, it has been reported that the center of plateau tends to be located central or lateral from the tibial canal axis. However, in the three dimensional analysis of author, the center of plateau was located on average 4.4 mm medial from the point of tibial canal axis passing through the plateau. The purpose of this study is to examine the placement of the tibial component in relation to the anatomical axis of the tibia in total knee arthroplasties for Korean patients and to identify this mismatch affecting the measurement of postoperative mechanical axis.

Measurements were performed on the pre- and postoperative radiographs of 60 osteoarthritic knees with varus deformity replaced between October 2005 and May 2008 using PFC. The inclusion criteria was the cases with the accurate coronal alignment of component, in which α angle ranged from 94 to 96° and β angle ranged from 89 to 91°. The mean age was 66.6 years (range, 54 to 79), and the body mass index was 27.0 kg/m2 (range, 20.7 to 37.7). Radiological measurements were performed using an orthoreontgenogram. Preoperatively, 30 patients with varus deformity lesser than vaurs 10° were classified to group A and 30 patients greater than vaurs 10° were classified to group B. Post-operatively, the distance between the midline of the tibial stem and anatomical axis (medial offset) was measured at the level of tibial resection. These distances were compared between the group A and B. The postoperative mechanical axes were compared between the group A and B. The intra- and inter-observer reliabilities were assessed. In this study, intraclass correlation coefficient values of all measurements were greater than 0.8.

The mean preoperative mechanical axes were varus 7.4±2.3° in group A and varus 16.9±4.0° in group B (p=0.000). The mean medial offsets were 2.5±1.9mm (range, −3.6 to 5.9) in group A and 3.9±2.7mm (range, −1.1 to 10.2) in group B (p=0.021). The tibial stems were located medial to anatomical axis in 22 knees (73.3%) of group A and 26 knees (86.7%) of group B. The mean postoperative mechanical axis were varus 1.3± 1.2° (range, varus 3.6 to valugs 1.6°) in group A and varus 2.5± 2.0° (range, varus 5.9 to valugs 2.1°) in group B (p=0.004).

In this study of TKA, the tibial component in relation to anatomical axis tends to be located medial. The postoperative mechanical axis remained more varus in spite of the accurate coronal alignment of the component as the preoperative varus deformity was more severe. This study suggests that the radiographic measurement of postoperative mechanical axis using a line passing the component center has the limitation.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 147 - 147
1 Mar 2010
Shin DS Lee H Kim T Oh K
Full Access

The anterior pelvic plane has been introduced as a concept of the reference plane to image free navigation-assisted cup placement of total hip arthroplasty. With the neutral pelvis, the anteversion relative to the conventional coordinate system is equal to the that of relation to the anatomical coordinate system. This is the rationale of image free navigation system. But, currently, two major concerns about image-free navigation assisted total hip arthroplasty are tilting of anatomic coordinate system and the cutaneous palpation procedure. Therefore, it was the goal of this study to provide both the bone anterior pelvic plane (Bone_APP) and the overlying soft tissue plane (Soft_APP) simultaneously, and to find possible correlations of biometrical parameters and effect of ante-version were an additional motivation of this study. 23 Korean adult patients underwent image-free navigation-assisted total hip arthroplasty. The tilting of Bone_APP, soft tissue thickness on ASIS, pubis, and then tilting of Soft_APP, and anteversion of cup were measured with reconstructed CT and 3D workstation system.

The average age was 66.1 years, the average height was 162.5cm at a weight of 59.2 kg. The average body mass index was 22.3. And the average lumbar lordosis was measured as 30.4 degrees. The soft tissue on the level of the pubis was 17.6 mm thicker than that on the level of ASIS in average. In all cases, Soft_APP was positive, that is from 3.5 to 16.5 degrees of backward rotation. We also found a high-intersubject variability in the Bone_APP from 13.4 of forward rotatation to 23 degrees of backward rotation. Overall, there are no correlation between biometrical parameters and difference of navigated data to others measured on CT. Averaged navigated data was 22.4 degrees. The average anatomic, operative, and planar anteversion were 29.2, 27.2 and 21.3 degrees respectively. The value of anteversion measured on the transverse plane and sagittal plane shows higher than navigated anteversion in paired comparison. This could be comprehended that the navigation system had under-estimated the anteversion than that of transverse and sagittal plane, This means navigation assessed pelvic plane as back ward tilting rather than forward tilting intraoperatively.

None of cases showed the Bone_APP was parallel to conventional coordinate system. Comparing the variable bone APP tilt, all of cases showed an backward tilted soft tissue plane. There were no correlation between bone APP and biometrical parameters. Overall, navigated data were less than anatomic and operative anteversion. Rather than anatomic coordinate system (Bone-APP), backward tilting due to overlying soft tissue (Soft-APP) might to make the navigated data have the tendency to under-estimated the anteversion of cup measured with CT. In conclusion, anterior pelvic plane does not satisfactory reliability with should be easily identified during operation. Image-free navigation system would take into account variations of individuals including both bone tilt and soft tissue plane.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 134 - 134
1 Mar 2010
Kim SW Limson MA Kim SB Arbatin JJF Park MS Shin JH Ju YS
Full Access

Background: Cervical myelopathy and radiculopathy has been treated commonly with anterior cervical decompression and fusion with autologous bone graft and anterior cervical plating. Long term results have shown excellent pain relief and 73%–90% fusion rates. However, the development of late adjacent-level disease has been reported following anterior cervical arthrodesis which recently have been correlated to clinical findings. The Bryan disc arthroplasty device was developed to preserve the kinematics of the functional spine unit thus preventing adjacent level disease. There have been few studies comparing the incidence of adjacent level changes in patients undergoing ACDF compared to implantation of a Bryan disc arthroplasty device.

Objectives: The object of this study is to compare the clinical results and radiographic outcomes of anterior cervical decompression and fusion versus cervical disc replacement using the Bryan Cervical Disc Prosthesis (Medtronic Sofamor Danek, Memphis, TN) in terms of overall range of motion (ROM) of the cervical spine; ROM, anterior intervertebral height (AIH), posterior intervertebral height (PIH) and radiographic changes at the implanted and adjacent levels.

Methods: The study consisted of 105 patients with symptomatic single or two-level cervical disc disease. Fifty-one received the Bryan Cervical Artificial Disc Prosthesis (Medtronic Sofamor Danek, Memphis, TN). A total of 63 Bryan disc were placed in these 51 patients. A single-level procedure was performed in 39 patients and a two-level procedure in the other twelve. The patient group who underwent ACDF totaled 54 patients which consisted of 26 single level cases and 28 double level cases. The Bryan group had a mean follow-up 19 months (12–38). The mean follow-up for the ACDF group was 20 months (12–40 months). All patients were evaluated using static and dynamic cervical spine radiographs as well as MR imaging.

All patients underwent anterior cervical discectomy followed by anterior cervical plating or implantation of the Bryan artificial disc prosthesis, done by one surgeon. Clinical evaluation included the visual analogue scale (VAS), and neck disability index (NDI). Radiographic evaluation included static and dynamic flexion-extension radiographs in an upright position using the computer software (Infinitt PiviewSTAR 5051) program. Range of motion/disc space angle and inter vertebral height were measured at the operative site and adjacent levels. Functional spinal unit (FSU) and overall sagittal alignment (C2–C7) were also measured pre-operatively, postoperatively and at final follow-up. ROM was calculated for all 3 areas and data collected were compared from pre operative to last follow-up as well as between the two groups. Radiographic assessment for adjacent level changes was also done. Radiologic change was analyzed using chi square test (95% confidence interval). Other data were analyzed using the mixed model. (SAS enterprise guide 4.1 version)

Results: There was clinical improvement within each group in terms of VAS and NDI scores from pre-op to final follow-up for both single (VAS: p=0.8371, NDI: p=0.2872) and double (VAS: p=0.2938, NDI: p=0.6753) level surgeries but not significantly between the two groups. Overall, ROM and intervertebral height was relatively well maintained during the follow-up in the Bryan group compared to ACDF. Comparing the pattern of ROM measurements from pre-op to final follow-up between the two arms regardless of the number of levels operated on; significant differences were noted for overall ROM of the cervical spine (p< .0001) and all other levels except at the upper level for single level surgeries (p=0.2872). In terms of inter vertebral height measurements from pre-op to final follow-up, statistically significant (p< 0.0001 and p=0.0172) differences in the pattern between the two groups were noted at all levels except for the AIH of single level surgeries at the upper (p=0.1264) and lower (p=0.7598) levels as well as PIH for double level surgeries at the upper (p=0.8363) level. Radiologic change was 3.5 times more observed for the ACDF group compared to the Bryan group.

Conclusion: Clinical status of both groups, regardless of the number of levels, showed improvement. Although clinical outcomes between the two groups were not significantly different at final follow-up, radiographic parameters, namely ROM and intervertebral heights at the operated site, some adjacent levels as well as FSU and overall sagittal alignment of the cervical spine were relatively well maintained in our Bryan group compared to our ACDF group. We surmise that to a certain degree, the maintenance of these parameters could contribute to reduce development of adjacent level change. Noteworthy is that radiographic change was 3.5 times more observed for ACDF surgeries. A longer period of evaluation is needed, to see if all these radiographic changes will translate to symptomatic adjacent level disease.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 175 - 175
1 Mar 2010
Shin CW
Full Access

The result of the revision TKRA relies upon the causes of failure, method of operation and surgical skill of the surgeon. For the success of the revision, surgeon should do his best from surgical planning to rehabilitation program. I have experienced more than 100 cases of revision TKRA and here I would like to share my surgical techniques of revision surgery in aseptic failure of the primary TKRA. An approach, implant selection, bony reconstruction and fixation methods used are just the same with the principles of other surgeons.

I will describe my surgical tips in removal of the implant, preservation of the joint line and morselized bone graft application.

For removal of implants, I used microsaw instead of Gigli saw. This is because microsaw has advantages of preserving the bone by easy approach to notch and posterior condylar area and less contamination risk.

After partial separation of bone and implant interface by microsaw, I would not remove the implant immediately. Instead I will tap medial and lateral condylar portion alternately with mallet repeatedly until I can see the movement of the prosthesis, and then I will gently remove the prosthesis. By this maneuver, the prosthesis is easily removed with less bony defect.

Before removal of femoral prosthesis, for joint line preservation, I will mark 5–6 cm proximal to the joint line on the femoral metaphyseal area with drill bit. In most revision cases, as the height of femoral prosthesis is maintained, this mark can be good landmark for the joint line insert of the trial prosthesis later at that level, thus the joint line can be preserved.

I also have special tips in morselized cancellous graft. After impaction of morselized bone, the bony fragments are easily dispersed and to prevent this phenomenon, some surgeons apply temporary cement coating over the bone. However, when using cement, the cement can intervene between bony fragment resulting in delay or failure of incorporation. Another disadvantage of cement coating is that the surface may be irregular and interfere with tight fitting of the prosthesis. My methods is by using haematoma to coat on the morselized bone followed by inserting the trial prosthesis in situ, and with knee deflate the torniquette. In most of the revision operation, 2 torniquette times is needed. It means that I deflate the torniquette a little earlier than 1st torniquette time. I do not irrigate for 10 ~ 15 min. After inflation of torniquette, gently remove the trial prosthesis and you can see beautiful shape of morselized graft which is well aggregated with haematoma. In this state, we do not need cement precoating on the morselized graft until the real prosthesis is implanted.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1587 - 1593
1 Dec 2009
Oh JH Kim SH Kim JH Shin YH Yoon JP Oh CH

This study examined the role of vitamin D as a factor accounting for fatty degeneration and muscle function in the rotator cuff. There were 366 patients with disorders of the shoulder. A total of 228 patients had a full-thickness tear (group 1) and 138 patients had no tear (group 2). All underwent magnetic resonance arthrography and an isokinetic muscle performance test. The serum concentrations of vitamin D (25(OH)D3) were measured.

In general, a lower serum level of vitamin D was related to higher fatty degeneration in the muscles of the cuff. Spearman’s correlation coefficients were 0.173 (p = 0.001), −0.181 (p = 0.001), and −0.117 (p = 0.026) for supraspinatus, infraspinatus and subscapularis, respectively. In group 1, multivariate linear regression analysis revealed that the serum level of vitamin D was an independent variable for fatty degeneration of the supraspinatus and infraspinatus.

The serum vitamin D level has a significant negative correlation with the fatty degeneration of the cuff muscle and a positive correlation with isokinetic muscle torque.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1601 - 1606
1 Dec 2009
Kwon BC Choi S Shin J Baek GH

Advanced osteoarthritis of the wrist or the distal articulation of the lunate with the capitate has traditionally been treated surgically by arthrodesis. In order to maintain movement, we performed proximal row carpectomy with capsular interposition arthroplasty as an alternative to arthrodesis in eight patients with advanced arthritis and retrospectively reviewed their clinical and radiographic outcomes after a mean follow-up of 41 months (13 to 53). The visual analogue scale (VAS) for pain at its worst and at rest, and the patient-rated wrist evaluation score improved significantly after surgery, whereas ranges of movement and grip strength were maintained at the pre-operative levels. Progression of arthritis in the radiocapitate joint was observed in three patients, but their outcomes were not significantly different from those without progression of arthritis.

Proximal row carpectomy with capsular interposition arthroplasty is a reasonable option for the treatment of patients with advanced arthritis of the wrist.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1383 - 1387
1 Oct 2009
Yoo WJ Choi IH Cho T Chung CY Shin Y Shin SJ

We evaluated radiological hip remodelling after shelf acetabuloplasty and sought to identify prognostic factors in 25 patients with a mean age of 8.9 years (7.0 to 12.3) who had unilateral Perthes’ disease with reducible subluxation of the hip in the fragmentation stage.

At a mean follow-up of 6.7 years (3.2 to 9.0), satisfactory remodelling was observed in 18 hips (72%). The type of labrum in hip abduction, as determined by intra-operative dynamic arthrography, was found to be a statistically significant prognostic factor (p = 0.012).

Shelf acetabuloplasty as containment surgery seems to be best indicated for hips in which there is not marked collapse of the epiphysis and in which the extruded epiphyseal segment slips easily underneath the labrum on abduction, without imposing undue pressure on the lateral edge of the acetabulum.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 184 - 184
1 Mar 2008
Shin H Yoon Y
Full Access

Heat generation during bone cutting operations inorthopaedics may cause thermal damage to the bone. During the bone cutting, the maximum temperature occurs on the contact surface between the bone and tool. Because of the low thermal conductivity and diffusivity, the temperature gradient of the bone interior is very high around the cutting site and the measurement of maximum temperature is difficult at the contact surface. While many researchers tried to measure the temperatures, they may have underestimated the temperatures of bone on account of measurement limitations. To solve this problem, we investigated the temperature distribution model of the bone interior during the milling operation and verified the model with a cutting experiment.

During the bone milling, most of the cutting energy is converted into the heat energy near the contact surface between the bone and tool. If the cutting tool moves on the bone surface, we can assume that a heat source moves on the bone surface at the speed of the feed rate. To predict the maximum temperature, we performed a milling experiment with fresh bovine cortical femurs. The feed rate were 2~9.8mm/s, the cutting depth were 0.3~1mm and the rotational speed were 30,000~50,000RPM. No irrigation solutions were applied. To measure the local temperatures around the tool, two infrared thermometers were attached behind the bur at 10mmintervals from the bur center. We calculated the maximum temperatures and errors from the measured temperatures.

The predicted maximum temperature increment was 55~131& #8451; as the cutting conditions change. The mean errors and standard deviation errors were several degrees. The increased feed rate and decreased cutting-depth reduced the maximum temperature.

Our observed temperature is quite higher than those in the previous studies. Because of the high temperature-gradient(57& #8451;/mm), the thermocouple alone will likely yield large errors and generally underestimate the temperatures of the bone interior. With a thermal damage criterion of 50& #8451;(& #916; T=13& #8451;), thermal damage may reach 1mm in depth. To reduce the thermal damage, it is recommended to increase feed rate and decrease cutting depth.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 19 - 19
1 Mar 2008
Madan S Feldman D Shin S Koval K
Full Access

To determine the effectiveness of six-axis analysis deformity correction using the Taylor Spatial Frame for the treatment of post-traumatic tibial malunions and non-unions, the study design was a retrospectively reviewed, consecutive series. Mean duration of follow-up: 3.2 years (range 2–4.2 years). All patients had been referred to a tertiary referral centre for deformity correction. Eighteen patients were included in the study (11 mal-unions and 7 nonunions). All deformities were post-traumatic in nature. The mean number of operations prior to the application of the spatial frame was 2.6 (range 1–6 operations). All patients completed the study. Six-axis analysis deformity correction using the Taylor Spatial Frame (Smith & Nephew, Memphis, TN) was used for correction of post-traumatic tibial malunion or nonunion. Nine patients had bone grafting at the time of frame application. One patient with a tibial plafond fracture simultaneously had deformity correction and an ankle fusion for a mobile atrophic nonunion. Two patients had infected tibial nonunions that were treated with multiple debridements, antibiotic beads, and bone grafting at the time of spatial frame application. A rotational gastrocnemius flap was used to cover a proximal third tibial defect in one patient. The average length of time the spatial frame was worn, time to healing, was 18.5 weeks (range 12–32 weeks). The main outcome measurements involved assessment of deformity correction in six axes, knee and ankle range of motion, incidence of infection, and return to preinjury activities.

Results: Seventeen of the 18 patients treated with the Taylor Spatial Frame, with adjunctive bone graft as necessary, achieved union and significant correction of their deformities in six axes, i.e. coronal angulation and translation, sagittal angulation and translation, rotation, and shortening. Fifteen of the 18 patients returned to their pre-injury activities at last follow-up.

Conclusion: Six-axis analysis deformity correction using the Taylor Spatial Frame is an effective technique in treating post-traumatic malunions and nonunions of the tibia, with several advantages over previously used devices.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 95 - 97
1 Jan 2008
Anthony SG Mudgal CS DeLaney TF Shin RD Raskin KA Ring DC

We describe a case of recurrent intravascular papillary endothelial hyperplasia involving the middle finger which was successfully-treated with photon and proton radiotherapy following two previous surgical excisions.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 527 - 531
1 Apr 2007
Yun Y Shin S Moon J

We reviewed 22 children with cubitus varus who had been treated by a reverse V osteotomy and fixation by cross-pinning and wiring. The mean pre-operative humeral-elbow-wrist angle was −16.9° (−25° to +9°) and at the latest follow-up it was +7.3° (−2° to +14°). No child had a lateral prominence greater than 5 mm after correction. An excellent result was achieved in 20 children and a good result in two. We believe that this osteotomy has the advantages of better inherent stability, the avoidance of a prominent lateral condyle after correction and firm fixation allowing early movement.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1390 - 1392
1 Oct 2006
Rhee KJ Kim KC Lee JK Hwang DS Shin HD Yang JY Kim YM

In a 41-year-old man, right-sided infraspinatus muscle weakness was associated with compression of the suprascapular nerve caused by a spinoglenoid ganglion cyst. The lesion was confirmed using electromyography and MRI. In addition, arthroscopy showed an incomplete discoid labrum. The free inner edge of the labrum was removed as in a meniscectomy of a discoid meniscus in the knee joint. Arthroscopic decompression of the cyst was performed through a juxtaglenoid capsulotomy which was left open. Neurological function recovered completely.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 255 - 260
1 Feb 2006
Shin EK Jones NF Lawrence JF

We have evaluated the clinical outcomes of simple excision, ulnar lengthening and the Sauvé-Kapandji procedure in the treatment of deformities of the forearm in patients with multiple hereditary osteochondromas. The medical records of 29 patients (33 forearms) were reviewed; 22 patients (22 forearms) underwent simple excision (four with ulnar lengthening) and seven the Sauvé-Kapandji procedure.

Simple excision increased the mean supination of the forearm from 63.2° to 75.0° (p = 0.049). Ulnar lengthening did not significantly affect the clinical outcome. The Sauvé-Kapandji technique improved the mean pronation from 33.6° to 55.0° (p = 0.047) and supination from 70.0° to 81.4° (p = 0.045). Simple excision may improve the range of movement of the forearm but will not halt the progression of disease, particularly in younger patients. No discernable clinical or radiological improvement was noted with ulnar lengthening. The Sauvé-Kapandji procedure combined with simple excision of osteochondromas can improve stability of the wrist, movement of the forearm and the radiological appearance.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 148 - 148
1 Feb 2004
Choi I Cho T Chung C Yoo W Shin Y
Full Access

Introduction: The authors introduce a modified technique of iliac splitting and expanding shelf (ISES) arthroplasty for severe LCPD, and report on the intermediate outcomes.

Materials and Methods: This new procedure is a modification of the previously reported tectoplasty of Saito (1986) and the shelf arthroplasty of Catterall (1992). Only the sartorius muscle and the indirect head of the rectus femoris muscle are detached, leaving the abductors intact. A superiorly hinged bony flap was raised from the lateral iliac wall just above the hip joint capsule. A corticocancellous bone plate was harvested from the inner table of the iliac wing, and was placed between the lateral hip joint capsule and the bony flap. The triangular space between the split iliac wall and the bone plate was packed with autogenous cancellous bone chips and Osteoset® (Wright-Medical, Arlington, Tennessee, USA). The repaired indirect head of the rectus femoris muscle gave stability to the shelf. After 4 weeks in a Petrie cast, the hip was mobilized, and partial weight bearing was started postoperative at 6 weeks. Twenty one hips in 21 children older than 8 years presenting with early (18 hips) and late (reossification) (3 hips) LCPD were treated by ISES arthroplasty. All patients were followed up for more than 2 years (range, 2 to 8.5 years).

Results: There were significant functional and radiological improvements after operation. One patient needed a secondary varus osteotomy to solve persistent subluxation. The poorest result occurred in a very obese child, presenting with early stage of Catterall IV involvement at age 11.5 years.

Discussion: Our modified technique of the shelf arthroplasty, sparing the abductor mechanism, appears to be a reliable and effective method to augment the superolateral coverage of the femoral head in severe LCPD.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 273 - 273
1 Mar 2003
Cho T Choi I Chung C Park M Park Y Shin
Full Access

The purpose of this study was to investigate the efficacy of oral alendronate for the older children with osteogenesis imperfecta. Eight boys and 6 girls with average age of 9.7 years were given oral alendronate, 10mg everyday for those > 35kg, 10mg every other day for those 20 – 35 kg, and 10mg every three days for those < 20 kg. Treatment period averaged 3.3 years (range, 2.1 to 3.6). The number of fractures decreased by 39% in the lower extremity, although not statistically significant. Ten patients or their parents reported improved well-being during the treatment period. Z score for bone mineral density improved from −3.75 to −1.18 in the lumbar spine, and from −3.84 to −2.74 in the femur neck. Restoration of the collapsed vertebral bodies was observed, and the metaphyseal bands appeared on the simple radiographs. Urinary excretion of calcium and N-telopeptide of type I collagen were decreased by 64% and 47%, respectively. Abdominal discomfort was reported in five patients, one of which needed temporary switch to intravenous protocol. Iliac crest biopsy including the physis showed expanded primary spongiosa area with numeric multi-nucleated cells, which had heterogenous immunoreactivity for osteoclast markers.

This study revealed beneficial effects of oral alendronate in osteogenesis imperfecta patients, supported by radiological, biochemical and histological findings. We believe that oral alendronate is a more convenient method of bisphosphonate treatment for osteogenesis imperfecta, especially in older children.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 223 - 223
1 Nov 2002
Lin C Chen P Huang G Shin M
Full Access

There is quite a high incidence of musculoskeletal disorders in the hemophiliac patients because of their insufficiency in blood coagulation. Knee joint disability is the most troublesome problem among the all. Repeated bruise and intra-articular hemorrhage may activate hypertrophic synovitis and progress to advanced arthritis. The characteristic clinical presentation is their fusiform limbs with moderate degree of contracture and deformity. Treatments include administration of specific coagulation factors, aspiration of hemarthrosis and proper bracing. Synovectomy will treat and retard the progression of the disease, while some advanced cases may end up to spontaneous fusion or need surgical arthrodesis. Total knee arthroplasty is another option for such a knee problem in hemophiliac patients.

We have done 26 total knee arthroplasties in 19 hemophiliac patients since 1986. Male is predominant with sex-linked inheritance with only one exception. The timing for them to have surgery is from 22 to 47 years old with mean age of 30. Gross patholgies of the knee lesion are quite universal as hypertrophy of hemosiderin deposited synovium, destruction of articular catilage, subchondral bone loss, marginal osteophytes formation, fibrous contracture around the joints. Two cases were excluded for other systemic disease.

With the help of supplementary coagulation factor, the surgical courses were rather smooth with one exception of septic shock episode. There were no infections in total series but three revisions of prosthesis were done because of loosening or malposition. All the patients were satisfied with the improvement of function score and range of knee motion. Total knee arthroplasty did a great success for the relief of pain and function for such a knee disorder. The only remained troublesome problem is the extremely high cost of the coagulation factor therapy which may be an economic shock to the patients.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 239 - 239
1 Nov 2002
Yoo M Cho Y Chun Y Pyo N Kim S Shin D
Full Access

We report the long-term radiographic results of the total hip arthroplasty with use of the cementless porous coated Harris-Galante (H-G) stem. Seventy-five consecutive patients, eighty-eight hips formed the basis of this study. Fifty patients were male, twenty-five patients were female, and thirteen patients were bilateral. The mean age of patients at operation was 42 years. They were followed up for an average of thirteen years four months (ten years two months to fourteen years four months). The diagnosis was avascular necrosis of the femoral head in 49 cases, degenerative osteoarthritis in 32 cases. Clinical results were estimated by modified Harris hip score and thigh pain, and radiographic results by periodically checked plain X-ray film. The average Harris hip score increased from 60 points preoperatively to 83 points at the most recent follow-up examination. The hip pain score increased from 31 points to 41 points. Clinically severe thigh pain was observed in 3 cases (4%). In radiographic evaluation, subsidence more than 5mm was seen in 2 cases (2%). Periprosthetic osteolytic lesion was observed in 15 cases (17%), but the lesions do not influence stability of the stem. Femoral stem stability by Engh was stable in 72 cases, fibrous stable in 12 cases, unstable in 4 cases. Pedestal formation, cortical hypertrophy of the distal femur, and stress shielding was observed more than 40%. Subcollar resorption was identified in 29% and ectopic ossification in 15%. Revision of the femoral stem was needed in 4 cases for aseptic loosening. At 10 years probability of survival of the stem using Kaplan-Meyer method was 95.5%. Use of the cementless H-G stem yielded the excellent long-term outcome, but osteolysis and stress shielding would be the main problems to solve.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 1086 - 1086
1 Sep 2002
BISHOP AT SHIN AY


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1023 - 1028
1 Sep 2001
Shin AY Weinstein LP Berger RA Bishop AT

We studied 57 patients with isolated lunotriquetral injuries treated by arthrodesis, direct ligament repair, or ligament reconstruction. The outcomes were compared by using written questionnaires, the Disabilities of the Arm, Shoulder and Hand (DASH) score, range of movement, strength, morbidity and rates of reoperation. Isolated lunotriquetral injury was confirmed by arthroscopy or arthrotomy. The mean age of the patients was 30.7 years (15.4 to 53.7) and the injuries were subacute or chronic in 98.2%. Eight patients underwent lunotriquetral reconstruction using a distally-based strip of the tendon of extensor carpi ulnaris, 27 had lunotriquetral repair and 22 had lunotriquetral arthrodesis. The mean follow-up was 9.5 years (2 to 22).

The probability of remaining free from complications at five years was 68.6% for reconstruction, 13.5% for repair, and less than 1% for arthrodesis. Of the lunotriquetral arthrodeses, 40.9% developed nonunion and 22.7% developed ulnocarpal impaction. The probability of not requiring further surgery at five years was 68.6% for reconstruction, 23.3% for repair and 21.8% for arthrodesis. The DASH scores for each group were not significantly different. Objective improvements in strength and movement, subjective indicators of pain relief and satisfaction were significantly higher in the lunotriquetral repair and reconstruction groups than in those undergoing arthrodesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 289 - 294
1 Mar 2001
Im G Kim D Shin J Hyun C Cho W

In 16 mature New Zealand white rabbits mesenchymal stem cells were aspirated from the bone marrow, cultured in monolayer and implanted on to a full-thickness osteochondral defect artificially made on the patellar groove of the same rabbit. A further 13 rabbits served as a control group. The rabbits were killed after 14 weeks. Healing of the defect was investigated histologically using haematoxylin and eosin and Safranin-O staining and with immunohistochemical staining for type-II collagen. We also used a reverse transcription-polymerase chain reaction (RT-PCR) to detect mRNA of type-I and type-II collagen.

The semiquantitative histological scores were significantly higher in the experimental group than in the control group (p < 0.05). In the experimental group immunohistochemical staining on newly formed cartilage was more intense for type-II collagen in the matrix and RT-PCR from regenerated cartilage detected mRNA for type-II collagen in mature chondrocytes. These findings suggest that repair of cartilage defects can be enhanced by the implantation of cultured mesenchymal stem cells.


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 2 | Pages 268 - 271
1 May 1954
Shun-Shin M