Advertisement for orthosearch.org.uk
Results 1 - 100 of 3679
Results per page:
Bone & Joint Research
Vol. 12, Issue 3 | Pages 165 - 177
1 Mar 2023
Boyer P Burns D Whyne C

Aims. An objective technological solution for tracking adherence to at-home shoulder physiotherapy is important for improving patient engagement and rehabilitation outcomes, but remains a significant challenge. The aim of this research was to evaluate performance of machine-learning (ML) methodologies for detecting and classifying inertial data collected during in-clinic and at-home shoulder physiotherapy exercise. Methods. A smartwatch was used to collect inertial data from 42 patients performing shoulder physiotherapy exercises for rotator cuff injuries in both in-clinic and at-home settings. A two-stage ML approach was used to detect out-of-distribution (OOD) data (to remove non-exercise data) and subsequently for classification of exercises. We evaluated the performance impact of grouping exercises by motion type, inclusion of non-exercise data for algorithm training, and a patient-specific approach to exercise classification. Algorithm performance was evaluated using both in-clinic and at-home data. Results. The patient-specific approach with engineered features achieved the highest in-clinic performance for differentiating physiotherapy exercise from non-exercise activity (area under the receiver operating characteristic (AUROC) = 0.924). Including non-exercise data in algorithm training further improved classifier performance (random forest, AUROC = 0.985). The highest accuracy achieved for classifying individual in-clinic exercises was 0.903, using a patient-specific method with deep neural network model extracted features. Grouping exercises by motion type improved exercise classification. For at-home data, OOD detection yielded similar performance with the non-exercise data in the algorithm training (fully convolutional network AUROC = 0.919). Conclusion. Including non-exercise data in algorithm training improves detection of exercises. A patient-specific approach leveraging data from earlier patient-supervised sessions should be considered but is highly dependent on per-patient data quality. Cite this article: Bone Joint Res 2023;12(3):165–177


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 117 - 117
1 Nov 2021
Longo UG
Full Access

The function of the upper extremity is highly dependent on correlated motion of the shoulder. The shoulder can be affected by several diseases. The most common are: rotator cuff tear (RCT), shoulder instability, shoulder osteoarthritis and fractures. Rotator cuff disease is a common disorder. It has a high prevalence rate, causing high direct and indirect costs. The appropriate treatment for RCT is debated. The American Academy Orthopaedic Surgeons guidelines state that surgical repair is an option for patients with chronic, symptomatic full-thickness RCT, but the quality of evidence is unconvincing. Thus, the AAOS recommendations are inconclusive. We are performing a randomized controlled trial to compare surgical and conservative treatment of RCT, in term of functional outcomes, rotator cuff integrity, muscle atrophy and fatty degeneration. Shoulder instability occurs when the head of the upper arm bone is forced out of the shoulder socket. Shoulder instabilities have been classified according to the etiology, the direction of instability, or on combinations thereof. The Thomas and Matsen classification, which is currently the most commonly utilized classification, divides shoulder instability events into the traumatic, unidirectional, Bankart lesion, and surgery (TUBS) and the atraumatic, multidirectional, bilateral, rehabilitation, and capsular shift (AMBRI) categories. The acquired instability overstress surgery (AIOS) category was then added. Surgical procedures for shoulder instability includes arthroscopic capsuloplasty, remplissage, bone block procedure or Latarjet procedure. Reverse total shoulder arthroplasty (RTSA) represents a good solution for the management of patients with osteoarthritis or fracture of the proximal humerus, with associated severe osteoporosis and RC dysfunction


Bone & Joint Open
Vol. 3, Issue 12 | Pages 977 - 990
23 Dec 2022
Latijnhouwers D Pedersen A Kristiansen E Cannegieter S Schreurs BW van den Hout W Nelissen R Gademan M

Aims. This study aimed to investigate the estimated change in primary and revision arthroplasty rate in the Netherlands and Denmark for hips, knees, and shoulders during the COVID-19 pandemic in 2020 (COVID-period). Additional points of focus included the comparison of patient characteristics and hospital type (2019 vs COVID-period), and the estimated loss of quality-adjusted life years (QALYs) and impact on waiting lists. Methods. All hip, knee, and shoulder arthroplasties (2014 to 2020) from the Dutch Arthroplasty Register, and hip and knee arthroplasties from the Danish Hip and Knee Arthroplasty Registries, were included. The expected number of arthroplasties per month in 2020 was estimated using Poisson regression, taking into account changes in age and sex distribution of the general Dutch/Danish population over time, calculating observed/expected (O/E) ratios. Country-specific proportions of patient characteristics and hospital type were calculated per indication category (osteoarthritis/other elective/acute). Waiting list outcomes including QALYs were estimated by modelling virtual waiting lists including 0%, 5% and 10% extra capacity. Results. During COVID-period, fewer arthroplasties were performed than expected (Netherlands: 20%; Denmark: 5%), with the lowest O/E in April. In the Netherlands, more acute indications were prioritized, resulting in more American Society of Anesthesiologists grade III to IV patients receiving surgery. In both countries, no other patient prioritization was present. Relatively more arthroplasties were performed in private hospitals. There were no clinically relevant differences in revision arthroplasties between pre-COVID and COVID-period. Estimated total health loss depending on extra capacity ranged from: 19,800 to 29,400 QALYs (Netherlands): 1,700 to 2,400 QALYs (Denmark). With no extra capacity it will take > 30 years to deplete the waiting lists. Conclusion. The COVID-19 pandemic had an enormous negative effect on arthroplasty rates, but more in the Netherlands than Denmark. In the Netherlands, hip and shoulder patients with acute indications were prioritized. Private hospitals filled in part of the capacity gap. QALY loss due to postponed arthroplasty surgeries is considerable. Cite this article: Bone Jt Open 2022;3(12):977–990


Bone & Joint 360
Vol. 13, Issue 1 | Pages 26 - 29
1 Feb 2024

The February 2024 Shoulder & Elbow Roundup. 360. looks at: Does indomethacin prevent heterotopic ossification following elbow fracture fixation?; Arthroscopic capsular shift in atraumatic shoulder joint instability; Ultrasound-guided lavage with corticosteroid injection versus sham; Combined surgical and exercise-based interventions following primary traumatic anterior shoulder dislocation: a systematic review and meta-analysis; Are vascularized fibula autografts a long-lasting reconstruction after intercalary resection of the humerus for primary bone tumours?; Anatomical versus reverse total shoulder arthroplasty with limited forward elevation; Tension band or plate fixation for simple displaced olecranon fractures?; Is long-term follow-up and monitoring in shoulder and elbow arthroplasty needed?


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 834 - 841
1 Aug 2024
French JMR Deere K Jones T Pegg DJ Reed MR Whitehouse MR Sayers A

Aims. The COVID-19 pandemic has disrupted the provision of arthroplasty services in England, Wales, and Northern Ireland. This study aimed to quantify the backlog, analyze national trends, and predict time to recovery. Methods. We performed an analysis of the mandatory prospective national registry of all independent and publicly funded hip, knee, shoulder, elbow, and ankle replacements in England, Wales, and Northern Ireland between January 2019 and December 2022 inclusive, totalling 729,642 operations. The deficit was calculated per year compared to a continuation of 2019 volume. Total deficit of cases between 2020 to 2022 was expressed as a percentage of 2019 volume. Sub-analyses were performed based on procedure type, country, and unit sector. Results. Between January 2020 and December 2022, there was a deficit of 158,994 joint replacements. This is equivalent to over two-thirds of a year of normal expected operating activity (71.6%). There were 104,724 (-47.1%) fewer performed in 2020, 41,928 (-18.9%) fewer performed in 2021, and 12,342 (-5.6%) fewer performed in 2022, respectively, than in 2019. Independent-sector procedures increased to make it the predominant arthroplasty provider (53% in 2022). NHS activity was 73.2% of 2019 levels, while independent activity increased to 126.8%. Wales (-136.3%) and Northern Ireland (-121.3%) recorded deficits of more than a year’s worth of procedures, substantially more than England (-66.7%). It would take until 2031 to eliminate this deficit with an immediate expansion of capacity over 2019 levels by 10%. Conclusion. The arthroplasty deficit following the COVID-19 pandemic is now equivalent to over two-thirds of a year of normal operating activity, and continues to increase. Patients awaiting different types of arthroplasty, in each country, have been affected disproportionately. A rapid and significant expansion in services is required to address the deficit, and will still take many years to rectify. Cite this article: Bone Joint J 2024;106-B(8):834–841


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 668 - 678
1 Jun 2023
Friedman RJ Boettcher ML Grey S Flurin P Wright TW Zuckerman JD Eichinger JK Roche C

Aims. The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system. Methods. We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217). Results. Relative to their preoperative condition, each glenoid cohort had significant improvements in clinical outcomes from two years to ten years after surgery. Patients with cage glenoids had significantly better clinical outcomes, with higher patient-reported outcome scores and significantly increased active range of motion, compared with those with keel and peg glenoids. Those with cage glenoids also had significantly fewer complications (keel: 13.3%, peg: 13.1%, cage: 7.4%), revisions (keel: 7.1%, peg 9.7%, cage 3.5%), and aseptic glenoid loosening and failure (keel: 4.7%, peg: 5.8%, cage: 2.5%). Regarding radiological outcomes, 70 patients (11.2%) with cage glenoids had glenoid radiolucent lines (RLLs). The cage glenoid RLL rate was 3.3-times (p < 0.001) less than those with keel glenoids (37.3%) and 4.6-times (p < 0.001) less than those with peg glenoids (51.2%). Conclusion. These findings show that good long-term clinical and radiological outcomes can be achieved with each of the three aTSA designs of glenoid component analyzed in this study. However, there were some differences in clinical and radiological outcomes: generally, cage glenoids performed best, followed by cemented keel glenoids, and finally cemented peg glenoids. Cite this article: Bone Joint J 2023;105-B(6):668–678


Bone & Joint Open
Vol. 3, Issue 10 | Pages 826 - 831
28 Oct 2022
Jukes C Dirckx M Bellringer S Chaundy W Phadnis J

Aims. The conventionally described mechanism of distal biceps tendon rupture (DBTR) is of a ‘considerable extension force suddenly applied to a resisting, actively flexed forearm’. This has been commonly paraphrased as an ‘eccentric contracture to a flexed elbow’. Both definitions have been frequently used in the literature with little objective analysis or citation. The aim of the present study was to use video footage of real time distal biceps ruptures to revisit and objectively define the mechanism of injury. Methods. An online search identified 61 videos reporting a DBTR. Videos were independently reviewed by three surgeons to assess forearm rotation, elbow flexion, shoulder position, and type of muscle contraction being exerted at the time of rupture. Prospective data on mechanism of injury and arm position was also collected concurrently for 22 consecutive patients diagnosed with an acute DBTR in order to corroborate the video analysis. Results. Four videos were excluded, leaving 57 for final analysis. Mechanisms of injury included deadlift, bicep curls, calisthenics, arm wrestling, heavy lifting, and boxing. In all, 98% of ruptures occurred with the arm in supination and 89% occurred at 0° to 10° of elbow flexion. Regarding muscle activity, 88% occurred during isometric contraction, 7% during eccentric contraction, and 5% during concentric contraction. Interobserver correlation scores were calculated as 0.66 to 0.89 using the free-marginal Fleiss Kappa tool. The prospectively collected patient data was consistent with the video analysis, with 82% of injuries occurring in supination and 95% in relative elbow extension. Conclusion. Contrary to the classically described injury mechanism, in this study the usual arm position during DBTR was forearm supination and elbow extension, and the muscle contraction was typically isometric. This was demonstrated for both video analysis and ‘real’ patients across a range of activities leading to rupture. Cite this article: Bone Jt Open 2022;3(10):826–831


Bone & Joint Open
Vol. 5, Issue 8 | Pages 637 - 643
6 Aug 2024
Abelleyra Lastoria DA Casey L Beni R Papanastasiou AV Kamyab AA Devetzis K Scott CEH Hing CB

Aims. Our primary aim was to establish the proportion of female orthopaedic consultants who perform arthroplasty via cases submitted to the National Joint Registry (NJR), which covers England, Wales, Northern Ireland, the Isle of Man, and Guernsey. Secondary aims included comparing time since specialist registration, private practice participation, and number of hospitals worked in between male and female surgeons. Methods. Publicly available data from the NJR was extracted on the types of arthroplasty performed by each surgeon, and the number of procedures of each type undertaken. Each surgeon was cross-referenced with the General Medical Council (GMC) website, using GMC number to extract surgeon demographic data. These included sex, region of practice, and dates of full and specialist registration. Results. Of 2,895 surgeons contributing to the NJR in 2023, 102 (4%) were female. The highest proportions of female surgeons were among those who performed elbow (n = 25; 5%), shoulder (n = 24; 4%), and ankle (n = 8; 4%) arthroplasty. Hip (n = 66; 3%) and knee arthroplasty (n = 39; 2%) had the lowest female representation. Female surgeons had been practising for a median of 10.4 years since specialist registration compared to 13.7 years for males (p < 0.001). Northern Ireland was the region with the highest proportion of female arthroplasty surgeons (8%). A greater proportion of male surgeons worked in private practice (63% vs 24%; p < 0.001) and in multiple hospitals (74% vs 40%; p < 0.001). Conclusion. Only 4% of surgeons currently contributing cases to the NJR are female, with the highest proportion performing elbow arthroplasty (5%). Female orthopaedic surgeons in the NJR are earlier in their careers than male surgeons, and are less involved in private practice. There is a wide geographical variation in the proportion of female arthroplasty surgeons. Cite this article: Bone Jt Open 2024;5(8):637–643


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1189 - 1195
1 Nov 2023
Kim JS Kim SH Kim SC Park JH Kim HG Lee SM Yoo JC

Aims. The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes. Methods. This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group). Results. Perforation of the vault of the glenoid (p = 0.018) and size mismatch in height (p < 0.001) and width (p = 0.013) were significantly more frequent in the ST group than in the SM group. There was no significant difference in the clinical scores and ROM in the two groups, two years postoperatively (all p > 0.05). In subgroup analysis, the VP group had significantly less inferior overhang (p = 0.009), more scapular notching (p = 0.018), and more size mismatch in height (p < 0.001) and width (p = 0.025) than the VNP group. Conclusion. In Asian patients with a small glenoid, using a 29.5 mm small baseplate at the time of RSA was more effective in reducing size mismatch between the glenoid and the baseplate, decreasing the incidence of perforation of the glenoid vault, and achieving optimal positioning of the baseplate compared with the use of a 33.8 mm standard baseplate. However, longer follow-up is required to assess the impact of these findings on the clinical outcomes. Cite this article: Bone Joint J 2023;105-B(11):1189–1195


Bone & Joint 360
Vol. 12, Issue 3 | Pages 27 - 30
1 Jun 2023

The June 2023 Shoulder & Elbow Roundup. 360. looks at: Proximal humerus fractures: what does the literature say now?; Infection risk of steroid injections and subsequent reverse shoulder arthroplasty; Surgical versus non-surgical management of humeral shaft fractures; Core outcome set needed for elbow arthroplasty; Minimally invasive approaches to locating radial nerve in the posterior humeral approach; Predictors of bone loss in anterior glenohumeral instability; Does the addition of motor control or strengthening exercises improve rotator cuff-related shoulder pain?; Terminology and diagnostic criteria used in patients with subacromial pain syndrome


Bone & Joint 360
Vol. 13, Issue 4 | Pages 26 - 29
2 Aug 2024

The August 2024 Shoulder & Elbow Roundup. 360. looks at: Comparing augmented and nonaugmented locking-plate fixation for proximal humeral fractures in the elderly; Elevated five-year mortality following shoulder arthroplasty for fracture; Total intravenous anaesthesia with propofol reduces discharge times compared with inhaled general anaesthesia in shoulder arthroscopy: a randomized controlled trial; The influence of obesity on outcomes following arthroscopic rotator cuff repair; Humeral component version has no effect on outcomes following reverse total shoulder arthroplasty: a prospective, double-blinded, randomized controlled trial; What is a meaningful improvement after total shoulder arthroplasty by implant type, preoperative diagnosis, and sex?; The safety of corticosteroid injection prior to shoulder arthroplasty: a systematic review; Mortality and subsequent fractures of patients with olecranon fractures compared to other upper limb osteoporotic fractures


Bone & Joint 360
Vol. 13, Issue 2 | Pages 30 - 33
1 Apr 2024

The April 2024 Shoulder & Elbow Roundup. 360. looks at: Acute rehabilitation following traumatic anterior shoulder dislocation (ARTISAN): pragmatic, multicentre, randomized controlled trial; Prevalence and predisposing factors of neuropathic pain in patients with rotator cuff tears; Are two plates better than one? The clavicle fracture reimagined; A single cell atlas of frozen shoulder capsule identifies features associated with inflammatory fibrosis resolution; Complication rates and deprivation go hand in hand with total shoulder arthroplasty; Longitudinal instability injuries of the forearm; A better than “best-fit circle” method for glenoid bone loss assessment; 3D supraspinatus muscle volume and intramuscular fatty infiltration after arthroscopic rotator cuff repair


Bone & Joint 360
Vol. 12, Issue 4 | Pages 26 - 29
1 Aug 2023

The August 2023 Shoulder & Elbow Roundup360 looks at: Motor control or strengthening exercises for rotator cuff-related shoulder pain? A multi-arm randomized controlled trial; Does the choice of antibiotic prophylaxis influence reoperation rate in primary shoulder arthroplasty?; Common shoulder injuries in sport: grading the evidence; The use of medial support screw was associated with axillary nerve injury after plate fixation of proximal humeral fracture using a minimally invasive deltoid-splitting approach; MRI predicts outcomes of conservative treatment in patients with lateral epicondylitis; Association between surgeon volume and patient outcomes after elective shoulder arthroplasty; Arthroscopic decompression of calcific tendinitis without cuff repair; Functional outcome after nonoperative management of minimally displaced greater tuberosity fractures and predictors of poorer patient experience


Bone & Joint 360
Vol. 13, Issue 3 | Pages 31 - 34
3 Jun 2024

The June 2024 Shoulder & Elbow Roundup. 360. looks at: Reverse versus anatomical total shoulder replacement for osteoarthritis? A UK national picture; Acute rehabilitation following traumatic anterior shoulder dislocation (ARTISAN): pragmatic, multicentre, randomized controlled trial; acid for rotator cuff repair: a systematic review and meta-analysis of randomized controlled trials; Metal or ceramic humeral head total shoulder arthroplasty: an analysis of data from the National Joint Registry; Platelet-rich plasma has better results for long-term functional improvement and pain relief for lateral epicondylitis: a systematic review and meta-analysis of randomized controlled trials; Quantitative fatty infiltration and 3D muscle volume after nonoperative treatment of symptomatic rotator cuff tears: a prospective MRI study of 79 patients; Locking plates for non-osteoporotic proximal humeral fractures in the long term; A systematic review of the treatment of primary acromioclavicular joint osteoarthritis


Bone & Joint 360
Vol. 12, Issue 2 | Pages 28 - 31
1 Apr 2023

The April 2023 Shoulder & Elbow Roundup. 360. looks at: Arthroscopic Bankart repair in athletes: in it for the long run?; Functional outcomes and the Wrightington classification of elbow fracture-dislocations; Hemiarthroplasty or ORIF intra-articular distal humerus fractures in older patients; Return to sport after total shoulder arthroplasty and hemiarthroplasty; Readmissions after shoulder arthroplasty; Arthroscopic Bankart repair in the longer term; Bankart repair with(out) remplissage or the Latarjet procedure? A systematic review and meta-analysis; Regaining motion among patients with shoulder pathology: are all exercises equal?


Bone & Joint 360
Vol. 12, Issue 6 | Pages 31 - 34
1 Dec 2023

The December 2023 Shoulder & Elbow Roundup. 360. looks at: Clavicle fractures: is the evidence changing practice?; Humeral shaft fractures, and another meta-analysis…let’s wait for the trials now!; Hemiarthroplasty or total elbow arthroplasty for distal humeral fractures…what does the registry say?; What to do with a first-time shoulder dislocation?; Deprivation indices and minimal clinically important difference for patient-reported outcomes after arthroscopic rotator cuff repair; Prospective randomized clinical trial of arthroscopic repair versus debridement for partial subscapularis tears; Long-term follow-up following closed reduction and early movement for simple dislocation of the elbow; Sternoclavicular joint reconstruction for traumatic acute and chronic anterior and posterior instability


Bone & Joint 360
Vol. 12, Issue 1 | Pages 30 - 33
1 Feb 2023

The February 2023 Shoulder & Elbow Roundup. 360. looks at: Arthroscopic capsular release or manipulation under anaesthesia for frozen shoulder?; Distal biceps repair through a single incision?; Distal biceps tendon ruptures: diagnostic strategy through physical examination; Postoperative multimodal opioid-sparing protocol vs standard opioid prescribing after knee or shoulder arthroscopy: a randomized clinical trial; Graft healing is more important than graft technique in massive rotator cuff tear; Subscapularis tenotomy versus peel after anatomic shoulder arthroplasty; Previous rotator cuff repair increases the risk of revision surgery for periprosthetic joint infection after reverse shoulder arthroplasty; Conservative versus operative treatment of acromial and scapular spine fractures following reverse total shoulder arthroplasty


Bone & Joint 360
Vol. 12, Issue 5 | Pages 30 - 34
1 Oct 2023

The October 2023 Shoulder & Elbow Roundup. 360. looks at: Arthroscopic capsular shift surgery in patients with atraumatic shoulder joint instability: a randomized, placebo-controlled trial; Superior capsular reconstruction partially restores native glenohumeral loads in a dynamic model; Gene expression in glenoid articular cartilage varies in acute instability, chronic instability, and osteoarthritis; Intra-articular injection versus interscalene brachial plexus block for acute-phase postoperative pain management after arthroscopic shoulder surgery; Level of pain catastrophizing rehab in subacromial impingement: secondary analyses from a pragmatic randomized controlled trial (the SExSI Trial); Anterosuperior versus deltopectoral approach for primary reverse total shoulder arthroplasty: a study of 3,902 cases from the Dutch National Arthroplasty Registry with a minimum follow-up of five years; Assessment of progression and clinical relevance of stress-shielding around press-fit radial head arthroplasty: a comparative study of two implants; A number of modifiable and non-modifiable factors increase the risk for elbow medial ulnar collateral ligament injury in baseball players: a systematic review


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 96 - 96
1 Apr 2019
Wang D Amis A
Full Access

Background. Medical advances and an ageing population mean that more people than ever rely on artificial joints. In the past years, shoulder joint replacement has developed rapidly and the numbers of shoulder prostheses implanted increased dramatically. Wear is one of the main contributors to the failure of shoulder implants. It is therefore important to measure the wear properties of the articulating surfaces within the joint in vitro. Investigation of wear characteristics through a comprehensive range of motion using a sophisticated shoulder simulator would reveal the durability of the material, the performance of component design and the safety analyses of prostheses. The purpose of the work was to develop and validate a multi-station shoulder simulator, which could accurately simulate physiological gleno-humeral forces and displacements during activities of daily living. Materials and Methods. Imperial shoulder simulator was designed with six articulating stations and one loaded soak control station for anatomical shoulder system wear simulation. It gives an adduction-abduction (AA) range of-15° to 55°, flexion-extension (FE) range of −90° to 90° and internal external rotation (IER) range of 15° to −90°. The rotations are applied simultaneously to the humeral implants by using stepper motors with integral position encoders. Axial and shear loadings to each glenoid implant were applied using pneumatic cylinders. Force controlled translations were recorded using load cells and LVDTs, and a data acquisition system. Pneumatic cylinders were also installed to work to counterbalance weights during the motion of adduction-abduction. All bearing pairs are within isolated and sealed test chambers to prevent loss of fluid through evaporation, and cross contamination of third body wear (as recommended in F1714-96). The simulator is controlled by LabVIEW program allowing to reproduce shoulder activities of daily living. Results. A commissioning trial was conducted when shoulder implants were subject to rotational and translational motions and loading to replicate the ‘combing’ activity of daily living. The motion ranges were typically 5° to 15° in AA, 15° to 80° in FE, and −30° to −20° in IER with applied loads from 60 to 440 N, principally along the medio-lateral direction. The waveform was at frequency of 1 Hz. The activity was loaded at 250,000 cycles around 3 full days, when test and control specimens should be cleaned, measured and then re-installed into the simulator. The results from kinematic and kinetic inputs and outputs were obtained from the trial study. Discussion. A multi-station shoulder simulator was successfully developed, which is capable of reproducing typical activities of daily living by applying physiological patterns of motion and load. The performance of the simulator was validated in the commissioning trial, which leads to evaluation of novel implant designs


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 620 - 626
1 May 2022
Stadecker M Gu A Ramamurti P Fassihi SC Wei C Agarwal AR Bovonratwet P Srikumaran U

Aims. Corticosteroid injections are often used to manage glenohumeral arthritis in patients who may be candidates for future total shoulder arthroplasty (TSA) or reverse shoulder arthroplasty (rTSA). In the conservative management of these patients, corticosteroid injections are often provided for symptomatic relief. The purpose of this study was to determine if the timing of corticosteroid injections prior to TSA or rTSA is associated with changes in rates of revision and periprosthetic joint infection (PJI) following these procedures. Methods. Data were collected from a national insurance database from January 2006 to December 2017. Patients who underwent shoulder corticosteroid injection within one year prior to ipsilateral TSA or rTSA were identified and stratified into the following cohorts: < three months, three to six months, six to nine months, and nine to 12 months from time of corticosteroid injection to TSA or rTSA. A control cohort with no corticosteroid injection within one year prior to TSA or rTSA was used for comparison. Univariate and multivariate analyses were conducted to determine the association between specific time intervals and outcomes. Results. In total, 4,252 patients were included in this study. Among those, 1,632 patients (38.4%) received corticosteroid injection(s) within one year prior to TSA or rTSA and 2,620 patients (61.6%) did not. On multivariate analysis, patients who received corticosteroid injection < three months prior to TSA or rTSA were at significantly increased risk for revision (odds ratio (OR) 2.61 (95% confidence interval (CI) 1.77 to 3.28); p < 0.001) when compared with the control cohort. However, there was no significant increase in revision risk for all other timing interval cohorts. Notably, Charlson Comorbidity Index ≥ 3 was a significant independent risk factor for all-cause revision (OR 4.00 (95% CI 1.40 to 8.92); p = 0.036). Conclusion. There is a time-dependent relationship between the preoperative timing of corticosteroid injection and the incidence of all-cause revision surgery following TSA or rTSA. This analysis suggests that an interval of at least three months should be maintained between corticosteroid injection and TSA or rTSA to minimize risks of subsequent revision surgery. Cite this article: Bone Joint J 2022;104-B(5):620–626


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_18 | Pages 13 - 13
1 Dec 2023
Elgendy M Makki D White C ElShafey A
Full Access

Introduction. We aim to assess whether radiographic characteristics of the greater tuberosity fragment can predict rotator cuff tears inpatients with anterior shoulder dislocations combined with an isolated fracture of the greater tuberosity. Methods. A retrospective single-centre case series of 61 consecutive patients that presented with anterior shoulder dislocations combined with an isolated fracture of the greater tuberosity between January 2018 and July 2022. Inclusion criteria: patients with atraumatic anterior shoulder dislocation associated with an isolated fracture of the greater tuberosity with a minimum follow-up of 3-months. Exclusion criteria: patients with other fractures of the proximal humerus or glenoid. Rotator cuff tears were diagnosed using magnetic resonance or ultrasound imaging. Greater tuberosity fragment size and displacement was calculated on plain radiographs using validated methods. Results. The case series was composed of 22 men and 39 women with a mean age of 65 years (29 - 91 years). The mean follow-up was 15months and median follow up 8.5 months (3 – 60 months). A rotator cuff tear was diagnosed in 14 patients (16%) and involved the supraspinatus (13), infraspinatus (4) and subscapularis (2). Full-thickness tears occurred in 6 patients and partial-thickness tears in 8patients. The mean time from initial injury to rotator cuff tear diagnosis was 5 months (2 – 22 months). The mean greater tuberosity fragment length was 23.4 mm in rotator cuff tear patients versus 32.6 mm in those without a tear (p = 0.006, CI: -15 - -2). The mean greater tuberosity. fragment width was 11.1 mm in rotator cuff tear patients versus 17.8 mm in those without a tear (p = 0.0004, CI: -10 - -2). There was no significant difference in the super inferior and anteroposterior fragment displacement between the two groups. Conclusion. In patients with shoulder dislocations combined with an isolated fracture of the greater tuberosity, rotator cuff tears are associated with a smaller sized greater tuberosity fragment


Bone & Joint 360
Vol. 11, Issue 6 | Pages 31 - 34
1 Dec 2022

The December 2022 Shoulder & Elbow Roundup. 360. looks at: Biceps tenotomy versus soft-tissue tenodesis in females aged 60 years and older with rotator cuff tears; Resistance training combined with corticosteroid injections or tendon needling in patients with lateral elbow tendinopathy; Two-year functional outcomes of completely displaced midshaft clavicle fractures in adolescents; Patients who undergo rotator cuff repair can safely return to driving at two weeks postoperatively; Are two plates better than one? A systematic review of dual plating for acute midshaft clavicle fractures; Treatment of acute distal biceps tendon ruptures; Rotator cuff tendinopathy: disability associated with depression rather than pathology severity; Coonrad-Morrey total elbow arthroplasty implications in young patients with post-traumatic sequelae


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 33 - 33
1 Dec 2022
Chen H Pike J Huang A
Full Access

The purpose of this prospective pilot study is to examine the feasibility of a physiotherapist led rapid access shoulder screening clinic (RASC). The goal of this study is to assess for improvements in patient access to care, patient reported outcome measures, patient reported experience measures, and cost outcomes using time driven activity based costing methods. Patient recruitment began in January 2021. Consultation requests from general practitioners and emergency rooms are analyzed and triaged through a central system. One half of patients awaiting consultation were triaged to the traditional route used at our center while the other half were triaged to be assessed at the RASC. Outcome measures consisting of the Simple Shoulder Test and SF-12 were recorded at the initial consultation and at follow up appointments. Cost benefit analysis was conducted using time driven activity based costing methods (TD-ABC). From January to August of 2021, 123 new patients were triaged for RASC assessment. On average, the RASC gets 10 new referrals per month. As of September 2021, there are 65 patients still on waitlist for RASC assessment with 58 having been assessed. Of the 58, 11% were discharged through the RASC, 48% pursued private physiotherapy, 14% had injections, 19% proceeded on for surgical consultation, and 8% did not show. Over time same time period, approximately 15 new patients were seen in consultation by the surgeon's office. Thirty-five responses were obtained from RASC patients during their initial intake assessment. The average age of respondents was 54.7 with 21 females and 14 males. Median SF-12 scores in the physical dimension (PCS-12) for RASC patients were 36.82 and mental (MCS-12) 49.38927. Median Simple Shoulder Test scores measured 6. Of the patients who responded to the follow up questionnaires after completing physiotherapy at the RASC, both the SF-12 and Simple Shoulder Test scoring improved. Median PCS-12 measured 47.08, MCS-12 of 55.87, and Simple Shoulder Test measured 8. RASC assessments by PT saved $172.91 per hour for consultation and $157.97 per hour for patient follow ups. Utilization of a physiotherapy led rapid access shoulder clinic resulted in improvements in patient outcomes as measured by the SF-12 and Simple Shoulder Test as well as significant direct cost savings. Proper triage protocols to identify which patients would be suitable for RASC assessment, buy-in from physiotherapists, and timely assessment of patients for early initiation of rehabilitation for shoulder pain is paramount to the success of a RASC system at our centre. Future research direction would be geared to analyzing a larger dataset as it becomes available


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 30 - 30
2 Jan 2024
Park H Kim R
Full Access

Glutamate regulates the expression of apoptosis-related genes and triggers the apoptosis of fibroblasts in rotator cuff tendons. Subacromial bursitis is always accompanied by symptomatic rotator cuff tear (RCT). However, no study has been reported on the presence of glutamate in subacromial bursa and on its involvement of shoulder pain in patients who had RCT. The purposes of this study were to determine whether the glutamate expression in subacromial bursa is associated with the presence of RCT and with the severity of shoulder pain accompanying RCT. Subacromial bursal tissues were harvested from patients who underwent arthroscopic rotator cuff tendon repair or glenoid labral repair with intact rotator cuff tendon. Glutamate tissue concentrations were measured, using a glutamate assay kit. Expressions of glutamate and its receptors in subacromial bursae were histologically determined. The sizes of RCT were determined by arthroscopic findings, using the DeOrio and Cofield classification. The severity of shoulder pain was determined, using visual analog scale (VAS). Any associations between glutamate concentrations and the size of RCT were evaluated, using logistic regression analysis. The correlation between glutamate concentrations and the severity of pain was determined, using the Pearson correlation coefficient. Differences with a probability <0.05 were considered statistically significant. Glutamate concentrations showed significant differences between the torn tendon group and the intact tendon group (P = 0.009). Concentrations of glutamate significantly increased according to increases in tear size (P < 0.001). In histological studies, the expressions of glutamate and of its ionotropic and metabotropic receptors have been confirmed in subacromial bursa. Glutamate concentrations were significantly correlated with pain on VAS (Rho=0.56 and P =0.01). The expression of glutamate in subacromial bursa is significantly associated with the presence of RCT and significantly correlated with its accompanying shoulder pain. Acknowledgements: This research was supported by the Basic Science Research Program, through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (NRF-2015R1D1A3A01018955 and 2017R1D1A1B03035232)


Bone & Joint Open
Vol. 3, Issue 10 | Pages 786 - 794
12 Oct 2022
Harrison CJ Plummer OR Dawson J Jenkinson C Hunt A Rodrigues JN

Aims. The aim of this study was to develop and evaluate machine-learning-based computerized adaptive tests (CATs) for the Oxford Hip Score (OHS), Oxford Knee Score (OKS), Oxford Shoulder Score (OSS), and the Oxford Elbow Score (OES) and its subscales. Methods. We developed CAT algorithms for the OHS, OKS, OSS, overall OES, and each of the OES subscales, using responses to the full-length questionnaires and a machine-learning technique called regression tree learning. The algorithms were evaluated through a series of simulation studies, in which they aimed to predict respondents’ full-length questionnaire scores from only a selection of their item responses. In each case, the total number of items used by the CAT algorithm was recorded and CAT scores were compared to full-length questionnaire scores by mean, SD, score distribution plots, Pearson’s correlation coefficient, intraclass correlation (ICC), and the Bland-Altman method. Differences between CAT scores and full-length questionnaire scores were contextualized through comparison to the instruments’ minimal clinically important difference (MCID). Results. The CAT algorithms accurately estimated 12-item questionnaire scores from between four and nine items. Scores followed a very similar distribution between CAT and full-length assessments, with the mean score difference ranging from 0.03 to 0.26 out of 48 points. Pearson’s correlation coefficient and ICC were 0.98 for each 12-item scale and 0.95 or higher for the OES subscales. In over 95% of cases, a patient’s CAT score was within five points of the full-length questionnaire score for each 12-item questionnaire. Conclusion. Oxford Hip Score, Oxford Knee Score, Oxford Shoulder Score, and Oxford Elbow Score (including separate subscale scores) CATs all markedly reduce the burden of items to be completed without sacrificing score accuracy. Cite this article: Bone Jt Open 2022;3(10):786–794


Shoulder septic arthritis is uncommon and frequently misdiagnosed, resulting in severe consequences. This study evaluated the demographics, bacteriological profile, antibiotic susceptibility, treatment regimens, and clinical outcomes. This is a 10-year retrospective observational analysis of 30 patients (20 males and 10 females) who were treated for septic arthritis of the shoulder. The data collecting process utilised clinical records, laboratory archives, and x-ray archives. We gathered demographic information, pre- and post-intervention clinical data, serum biochemical markers, and the results of imaging examinations. All patients had a surgical arthrotomy and joint debridement in the operating room, and specimens were taken for culture and sensitivity testing. The specimens were cultivated for at least seventy-two hours. Shoulder joint ranges of motion, comorbidities, and the presence of osteomyelitis were assessed clinically to determine the outcome. All statistical analyses were conducted using the STATA 17 statistical software. Analysis of correlation between categorical variables was performed using the chi-squared test. The majority of the study patients were black Africans (97%). The age range of the group was from 8 days to 17 years. At presentation, 33% of patients had a low-grade fever, whereas the majority (60%) had normal body temperature. The average length of symptoms was 3.9 days (ranged from 1 day to 15 days), and the majority of patients had an increased white cell count (83%) and C-reactive protein (98%). There was accumulation of fluid in the joint of all individuals who received shoulder ultrasound imaging. We noted a significant incidence of gram-positive cocci, which were mostly susceptible to first-line antibiotics. Shoulder stiffness affected 63% of patients and chronic osteomyelitis affected 50% of individuals. Neither the severity nor the duration of the symptoms was related to an increased risk of osteomyelitis. The results of this study revealed that the clinical characteristics and bacterial profile of septic arthritis of the shoulder conform to typical patterns. The likelihood of osteomyelitis and an unfavourable prognosis is considerable


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 68 - 68
23 Feb 2023
Lynskey S Ziemann M Jamnick N Gill S McGee S Sominsky L Page R
Full Access

Osteoarthritis (OA) is a disease of the synovial joint with synovial inflammation, capsular contracture, articular cartilage degradation, subchondral sclerosis and osteophyte formation contributing to pain and disability. Transcriptomic datasets have identified genetic loci in hip and knee OA demonstrating joint specificity. A limited number of studies have directly investigated transcriptional changes in shoulder OA. Further, gene expression patterns of periarticular tissues in OA have not been thoroughly investigated. This prospective case control series details transcriptomic expression of shoulder OA by analysing periarticular tissues in patients undergoing shoulder replacement for OA as correlated with a validated patient reported outcome measure of shoulder function, an increasing (clinically worsening) QuickDASH score. We then compared transcriptomic expression profiles in capsular tissue biopsies from the OA group (N=6) as compared to patients undergoing shoulder stabilisation for recurrent instability (the control group, N=26). Results indicated that top ranked genes associated with increasing QuickDASH score across all tissues involved inflammation and response to stress, namely interleukins, chemokines, complement components, nuclear response factors and immediate early response genes. Some of these genes were upregulated, and some downregulated, suggestive of a state of flux between inflammatory and anti-inflammatory signalling pathways. We have also described gene expression pathways in shoulder OA not previously identified in hip and knee OA, as well as novel genes involved in shoulder OA


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 34 - 34
1 Dec 2022
Lapner P Pollock J Hodgdon T Sheikh A Shamloo A Fernandez AA McIlquham K Desjardins M Drosdowech D Nam D Rouleau D
Full Access

The diagnosis of infection following shoulder arthroplasty is notoriously difficult. The prevalence of prosthetic shoulder infection after arthroplasty ranges from 3.9 – 15.4% and the most common infective organism is Cutibacterium acnes. Current preoperative diagnostic tests fail to provide a reliable means of diagnosis including WBC, ESR, CRP and joint aspiration. Fluoroscopic-guided percutaneous synovial biopsy (PSB) has previously been reported in the context of a pilot study and demonstrated promising results. The purpose of this study was to determine the diagnostic accuracy of percutaneous synovial biopsy compared with open culture results (gold standard). This was a multicenter prospective cohort study involving four sites and 98 patients who underwent revision shoulder arthroplasty. The cohort was 60% female with a mean age was 65 years (range 36-83 years). Enrollment occurred between June 2014 and November 2021. Pre-operative fluoroscopy-guided synovial biopsies were carried out by musculoskeletal radiologists prior to revision surgery. A minimum of five synovial capsular tissue biopsies were obtained from five separate regions in the shoulder. Revision shoulder arthroplasty was performed by fellowship-trained shoulder surgeons. Intraoperative tissue samples were taken from five regions of the joint capsule during revision surgery. Of 98 patients who underwent revision surgery, 71 patients underwent both the synovial biopsy and open biopsy at time of revision surgery. Nineteen percent had positive infection based on PSB, and 22% had confirmed culture positive infections based on intra-operative tissue sampling. The diagnostic accuracy of PSB compared with open biopsy results were as follows: sensitivity 0.37 (95%CI 0.13-0.61), specificity 0.81 (95%CI 0.7-0.91), positive predictive value 0.37 (95%CI 0.13 – 0.61), negative predictive value 0.81 (95%CI 0.70-0.91), positive likelihood ratio 1.98 and negative likelihood ratio 0.77. A patient with a positive pre-operative PSB undergoing revision surgery had an 37% probability of having true positive infection. A patient with a negative pre-operative PSB has an 81% chance of being infection-free. PSB appears to be of value mainly in ruling out the presence of peri-prosthetic infection. However, poor likelihood ratios suggest that other ancillary tests are required in the pre-operative workup of the potentially infected patient


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 6 - 6
1 Dec 2014
Lamb JN Varghese M Venkateswaran B
Full Access

This study aims to correlate Oxford shoulder score (OSS) to EQ5D score in healthy patients presenting to a shoulder clinic with shoulder pain. OSS and EQ5D scores were collected prospectively from 101 consecutive patients presenting with shoulder pain in a shoulder clinic at one specialist centre. Patients with ASA > 2 and other significant joint arthritis were excluded from the study. Scores were collected from electronic patient records. Spearman's rho correlation of oxford shoulder scores and EQ5D scores was completed. Mean age of subjects was 51.8 (range 19.1–81.9) years, 55 of 101 subjects were men (54%). Median OSS was 26 (range 3–48) and median EQ5D score was 0.76 (range 0–0.76). Correlation for all patients was 0.624 (Sig p<0.001). This study demonstrates a strong correlation between Oxford shoulder scoring and EQ5D in a fit and well shoulder surgery clinic population. It is possible that Oxford shoulder scores may be a useful indicator of quality of life in healthy shoulder clinic patients presenting with shoulder pain


Bone & Joint Open
Vol. 2, Issue 7 | Pages 522 - 529
13 Jul 2021
Nicholson JA Clement ND Clelland AD MacDonald DJ Simpson AHRW Robinson CM

Aims. It is unclear whether acute plate fixation facilitates earlier return of normal shoulder function following a displaced mid-shaft clavicular fracture compared with nonoperative management when union occurs. The primary aim of this study was to establish whether acute plate fixation was associated with a greater return of normal shoulder function when compared with nonoperative management in patients who unite their fractures. The secondary aim was to investigate whether there were identifiable predictors associated with return of normal shoulder function in patients who achieve union with nonoperative management. Methods. Patient data from a randomized controlled trial were used to compare acute plate fixation with nonoperative management of united fractures. Return of shoulder function was based on the age- and sex-matched Disabilities of the Arm, Shoulder and Hand (DASH) scores for the cohort. Independent predictors of an early recovery of normal shoulder function were investigated using a separate prospective series of consecutive nonoperative displaced mid-shaft clavicular fractures recruited over a two-year period (aged ≥ 16 years). Patient demographics and functional recovery were assessed over the six months post-injury using a standardized protocol. Results. Data from the randomized controlled trial consisted of 86 patients who underwent operative fixation compared with 76 patients that united with nonoperative treatment. The recovery of normal shoulder function, as defined by a DASH score within the predicted 95% confidence interval for each respective patient, was similar between each group at six weeks (operative 26.7% vs nonoperative 25.0%, p = 0.800), three months (52.3% vs 44.2%, p = 0.768), and six months post-injury (86.0% vs 90.8%, p = 0.349). The mean DASH score and return to work were also comparable at each timepoint. In the prospective cohort, 86.5% (n = 173/200) achieved union by six months post-injury (follow-up rate 88.5%, n = 200/226). Regression analysis found that no specific patient, injury, or fracture predictor was associated with an early return of function at six or 12 weeks. Conclusion. Return of normal shoulder function was comparable between acute plate fixation and nonoperative management when union was achieved. One in two patients will have recovery of normal shoulder function at three months, increasing to nine out of ten patients at six months following injury when union occurs, irrespective of initial treatment. Cite this article: Bone Jt Open 2021;2(7):522–529


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 22 - 22
7 Nov 2023
Du Plessis J Kazee N Lewis A Steyn S Van Deventer S
Full Access

The choice of whether to perform antegrade intramedullary nailing (IMN) or plate fixation (PF) poses a conundrum for the surgeon who must strike the balance between anatomical restoration while reducing elbow and shoulder functional impairment. Most humeral middle third shaft fractures are amenable to conservative management given the considerable acceptable deformity and anatomical compensation by patients. This study is concerned with the patient reported outcomes regarding shoulder and elbow function for IMN and PF respectively. A prospective cohort study following up all the cases treated surgically for middle third humeral fractures from 2016 to 2022 at a single centre. Telephonically an analogue pain score, an American Shoulder and Elbow Society (ASES) score for shoulder function and the Oxford Elbow score (OES) for elbow function were obtained. One hundred and three patients met the inclusion criteria. Twenty four patients participated in the study, fifteen had IMN (62.5%) and nine had PF (37.5%.). The shoulder function outcomes showed no statistical difference with an average ASES score of sixty-six for the IMN group and sixty-nine for the PF group. Women and employed individuals expressed greater functional impairment. Hand dominance has no impact on the scores of elbow and shoulder function post operatively. The impairment of abduction score post antegrade nailing was higher in the antegrade nailing group than the plated group. The OES demonstrated greater variance in elbow function in the PF group with the IMN group expressing greater elbow disfunction. This study confirms that treatment of middle third humerus shaft fractures by plate fixation is marginally superior to antegrade intramedullary nailing in preserving elbow function and abduction ability


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 23 - 23
7 Nov 2023
Mulaudzi NP Mzayiya N Rachuene P
Full Access

Os acromiale is a developmental defect caused by failure of fusion of the anterior epiphysis of the acromion between the ages of 22 and 25. The prevalence of os acromiale in the general population ranges from 1.4% to 15%. Os acromiale has been reported as a contributory factor to shoulder impingement symptoms and rotator cuff injuries, despite being a common incidental observation. In this retrospective study, we examined the prevalence of os acromiale in black African patients with shoulder pain. We retrospectively reviewed the clinical records, radiographs, and magnetic resonance imaging (MRI) scans of 119 patients who presented with atraumatic and minor traumatic shoulder pain at a single institution over a one-year period. Anteroposterior, scapula Y-view, and axillary view plain images were initially evaluated for the presence of os acromiale, and this was corroborated with axial MRI image findings. Patients with verified os acromiale had their medical records reviewed to determine their first complaint and the results of their clinical examination and imaging examination. Radiographs and MRI on 24 patients (20%) revealed an osacromiale. This cohort had a mean age of 59.2 years, and there were significantly more females (65%) than males. Meso-acromion was identified as the most prevalent type (n=11), followed by pre-os acromion (n=7). All patients underwent bilateral shoulder x-rays, and 45 percent of patients were found to have bilateral meso- acromion. Most patients (70%) were reported to have unstable os acromiale with subacromial impingement symptoms, and nine patients (36%) had confirmed rotator cuff tears based on clinical and Mri findings. Surgery was necessary for 47% of the 24 patients with confirmed Os acromiale (arthroscopic surgery, n=7; open surgery, n=1) in order to treat their symptoms. The prevalence of os acromiale in our African patients with atraumatic shoulder symptoms is greater than that reported in the general population. Os acromiale is a rare condition that should always be considered when evaluating shoulder pain patients


Bone & Joint Open
Vol. 5, Issue 7 | Pages 543 - 549
3 Jul 2024
Davies AR Sabharwal S Reilly P Sankey RA Griffiths D Archer S

Aims

Shoulder arthroplasty is effective in the management of end-stage glenohumeral joint arthritis. However, it is major surgery and patients must balance multiple factors when considering the procedure. An understanding of patients’ decision-making processes may facilitate greater support of those considering shoulder arthroplasty and inform the outcomes of future research.

Methods

Participants were recruited from waiting lists of three consultant upper limb surgeons across two NHS hospitals. Semi-structured interviews were conducted with 12 participants who were awaiting elective shoulder arthroplasty. Transcribed interviews were analyzed using a grounded theory approach. Systematic coding was performed; initial codes were categorized and further developed into summary narratives through a process of discussion and refinement. Data collection and analyses continued until thematic saturation was reached.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 224 - 228
1 Feb 2014
Simone JP Streubel PH Athwal GS Sperling JW Schleck CD Cofield RH

We assessed the clinical results, radiographic outcomes and complications of patients undergoing total shoulder replacement (TSR) for osteoarthritis with concurrent repair of a full-thickness rotator cuff tear. Between 1996 and 2010, 45 of 932 patients (4.8%) undergoing TSR for osteoarthritis underwent rotator cuff repair. The final study group comprised 33 patients with a mean follow-up of 4.7 years (3 months to 13 years). Tears were classified into small (10), medium (14), large (9) or massive (0). On a scale of 1 to 5, pain decreased from a mean of 4.7 to 1.7 (p = < 0.0001), the mean forward elevation improved from 99° to 139° (p = < 0.0001), and the mean external rotation improved from 20° (0° to 75°) to 49° (20° to 80°) (p = < 0.0001). The improvement in elevation was greater in those with a small tear (p = 0.03). Radiographic evidence of instability developed in six patients with medium or large tears, indicating lack of rotator cuff healing. In all, six glenoid components, including one with instability, were radiologically at risk of loosening. Complications were noted in five patients, all with medium or large tears; four of these had symptomatic instability and one sustained a late peri-prosthetic fracture. Four patients (12%) required further surgery, three with instability and one with a peri-prosthetic humeral fracture. . Consideration should be given to performing rotator cuff repair for stable shoulders during anatomical TSR, but reverse replacement should be considered for older, less active patients with larger tears. Cite this article: Bone Joint J 2014;96-B:224–8


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 67 - 67
1 Nov 2018
Bouaicha S Ernstbrunner L Jud L Meyer D Snedeker J Bachmann E
Full Access

Tear pattern and tendon involvement are risk factors for the development of a pseudoparalytic shoulder. However, some patients have similar tendon involvement but significantly different active forward flexion. In these cases, it remains unclear why some patients suffer from pseudoparalysis and others with the same tear pattern show good active range of motion. Moment arms (MA) and force vectors of the RC and the deltoid muscle play an important role in the muscular equilibrium to stabilize the glenohumeral joint. Biomechanical and clinical analyses were conducted calculating different MA-ratios of the RC and the deltoid muscle using computer rigid body simulation and a retrospective radiographic investigation of two cohorts with and without pseudoparalysis and massive RC tears. Idealized MAs were represented by two spheres concentric to the joints centre of rotation either spanning to the humeral head or deltoid origin of the acromion. Individual ratios of the RC /deltoid MAs on antero-posterior radiographs using the newly introduced Shoulder Abduction Moment (SAM) Index was compared between the pseudoparalytic and non-pseudoparalytic patients. Decrease of RC activity and improved glenohumeral stability (+14%) was found in simulations for MA ratios with larger diameters of the humeral head which also were consequently beneficial for the (remaining) RC. Clinical investigation of the MA-ratio showed significant risk of having pseudoparalysis in patients with massive tears and a SAM Index <0.77 (OR=11). The SAM index, representing individual biomechanical characteristics of shoulder morphology has an impact on the presence or absence of pseudoparalysis in shoulders with massive RC tears


Bone & Joint Research
Vol. 11, Issue 8 | Pages 541 - 547
17 Aug 2022
Walter N Hierl K Brochhausen C Alt V Rupp M

Aims

This observational cross-sectional study aimed to answer the following questions: 1) how has nonunion incidence developed from 2009 to 2019 in a nationwide cohort; 2) what is the age and sex distribution of nonunions for distinct anatomical nonunion localizations; and 3) how high were the costs for surgical nonunion treatment in a level 1 trauma centre in Germany?

Methods

Data consisting of annual International Classification of Diseases (ICD)-10 diagnosis codes from German medical institutions from 2009 to 2019, provided by the Federal Statistical Office of Germany (Destatis), were analyzed. Nonunion incidence was calculated for anatomical localization, sex, and age groups. Incidence rate ratios (IRRs) were determined and compared with a two-sample z-test. Diagnosis-related group (DRG)-reimbursement and length of hospital stay were retrospectively retrieved for each anatomical localization, considering 210 patients.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 463 - 463
1 Nov 2011
Walker D Cleppe H Sahajpal D Wright T Banks S
Full Access

Reverse shoulder arthroplasty (RSA) is increasingly utilized to restore shoulder function in patients with osteoarthritis and rotator cuff deficiency. There is currently little known about shoulder function after RSA or if differences in surgical technique or implant design affect shoulder performance. The purpose of this study was to quantify scapulohumeral rhythm in patients with RSA during loaded and unloaded shoulder abduction. Eleven patients with RSA performed shoulder abduction (elevation and lowering) with and without a handheld 3kg weight during fluoroscopic imaging. Three RSA designs were included. We used model-image registration techniques to determine the 3D position and orientation of the implants. Cubic curves were fit to the humeral elevation as a function of the scapular elevation over the entire motion. The slope of this curve was used to determine the scapulohumeral rhythm (SHR). For abduction above 40°, shoulders with RSA exhibited an average SHR of 1.5:1. There was no significant difference in SHR between shoulder abduction with and without 3kg handheld weights (1.6±0.2 unweighted vs. 1.4±0.1 weighted), nor was there a significant difference between elevation and lowering. SHR was highly variable for abduction less than 40°, with SHR ranging from a low of 1 to greater than 10. For these very small groups, there was no apparent pattern of differences between implant designs having differing degrees of lateral offset. At arm elevation angles less than 40°, SHR in RSA shoulders is highly variable and the mean SHR (2–5) with RSA appears higher than SHR in normal shoulders (2–3). At higher elevation angles, SHR in shoulders with RSA (1.5–1.8) is much more consistent and appears lower than SHR in normal shoulders (2–4). With the small subject cohort, it was not possible to demonstrate differences between subjects with different implant designs. Ongoing analysis of reverse shoulder function with larger cohort sizes will allow us to refine our observations and determine if there are differences in shoulder function due to implant design, preoperative condition and rehabilitation protocols


Bone & Joint Open
Vol. 2, Issue 1 | Pages 58 - 65
22 Jan 2021
Karssiens TJ Gill JR Sunil Kumar KH Sjolin SU

Aims. The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis. Methods. From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration. Results. Five shoulders underwent revision surgery (3.5%); three for rotator cuff failure, one for infection, and one for component malposition. Survivorship of the implant was 95.4% (95% confidence interval 90.1% to 97.9%) at five and nine years. Mean OSS improved significantly compared to preoperative values from 19.0 (1 to 35) to 43.3 (7 to 48) (p < 0.001). Radiological analysis was undertaken for 99 shoulders. This revealed humeral RLLs in one case (1%), glenoid RLLs in 15 cases (15.2%), and radiological rotator cuff failure in 22 cases (22.2%). Conclusion. This prospective cohort study shows encouraging short- to mid-term survivorship and clinical and radiological results for the Mathys Affinis Short, Short Stem Total Shoulder Prosthesis. Level of Evidence: IV. Cite this article: Bone Jt Open 2021;2(1):58–65


Bone & Joint Research
Vol. 12, Issue 10 | Pages 636 - 643
10 Oct 2023
Hamilton V Sheikh S Szczepanska A Maskell N Hamilton F Reid JP Bzdek BR Murray JRD

Aims

Orthopaedic surgery uses many varied instruments with high-speed, high-impact, thermal energy and sometimes heavy instruments, all of which potentially result in aerosolization of contaminated blood, tissue, and bone, raising concerns for clinicians’ health. This study quantifies the aerosol exposure by measuring the number and size distribution of the particles reaching the lead surgeon during key orthopaedic operations.

Methods

The aerosol yield from 17 orthopaedic open surgeries (on the knee, hip, and shoulder) was recorded at the position of the lead surgeon using an Aerodynamic Particle Sizer (APS; 0.5 to 20 μm diameter particles) sampling at 1 s time resolution. Through timestamping, detected aerosol was attributed to specific procedures.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 360 - 360
1 Jul 2008
Alshryda S Tripurneni V Vinayagam R Raju P Bayliss NC
Full Access

Background: One stop shoulder clinic was established in the North Tees University Hospital as part of conjoint effort between the department of trauma and orthopaedics and radiology in the year 2005. A consultant shoulder surgeon, consultant radiologist, extended scope shoulder physiotherapist and shoulder nurse practitioners run the clinic on weekly basis. The aims are:. Immediate and more accurate diagnosis and plan accordingly. Avoid unnecessary or inappropriate treatment while waiting for radiological test. High patient satisfaction. Reduce waiting time for definitive treatment. Reduce number of patients’ visits. Improve and advance clinical and radiological skills. Reduce the cost to the NHS. Promote a multi-disciplinary approach to patient healthcare. Methods and materials: A retrospective study of 150 patients who had been seen in the one stop shoulder clinic and conventional clinic. We studied the number of hospital visits, the waiting time for final intervention and or discharge, the accuracy of initial diagnosis and treatment and the cost-benefit analysis. Results and discussions: One-stop clinics have been successfully established in a few fields of medicine. One stop breast lump clinic has been running for almost 10 years with a very good reputation of rapid, accurate and cost-effective diagnosis of breast lumps. Similar successful examples have been emerged in gynaecology such as fertility clinic and uterine bleeding clinic; and in urology such as haematuria clinic. To our best knowledge, this is the first study that investigated the one-stop clinic in shoulder problems. Our results showed similar trend of success in term of reduction of patients’ hospital visits, waiting time to treatment and accuracy of the diagnosis. We also conducted a cost-benefit analysis of the one stop shoulder clinic in comparison with the conventional shoulder clinic and we concluded that it is cost effectiveness


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 109 - 109
10 Feb 2023
Sun J Tan SE Sevao J
Full Access

Anatomically specific fixation devices have become mainstream, yet there are anatomical regions and clinical conditions where no pre-contoured plates are available, such as for glenohumeral arthrodesis. In a case series of 4 glenohumeral arthrodesis patients, a consultant orthopaedic surgeon at GCUH implemented 3D printing technology to create reconstructions of each patient's shoulder girdle to pre-contour arthrodesis plates. Our aim was to quantify the cost-benefit & intra-operative time savings of this technique in glenohumeral arthrodesis. We hypothesized that the use of 3D printing for creating patient specific implants through pre-operative contouring of plates will lead to intra-operative time and cost savings by minimising time spent bending plates during surgery. This study analysed 4 patients who underwent shoulder arthrodesis by a single consultant orthopaedic surgeon at GCUH between 2017-2021. A CT-based life-size model of each patient's shoulder girdle was 3D printed using freely available computer software programs: 3D Slicer, Blender, Mesh Mixer & Cura. Once the patient's 3D model was created, plate benders were used to contour the plate pre-op, which was then sterilised prior to surgery. Arthrodesis was performed according to AO principles of fixation. The time spent pre-bending the plate using the 3D model was calculated to analyse the intra-op time and cost-saving benefits. For the 4 cases, the plate pre-bending times were 45, 40, 45 & 20 minutes (average 38.8 mins). The intra-op correction time to make small adjustments to the plate was 2 min/ case. 3 plates needed minor (3 degree) adjustment to fine-tune scapula spine contouring. 1 plate needed a 5 degree correction to fine-tune hand position. On average, the pre-bending of the plate saved approximately 38.8 mins intra-op/ case. These shorter anaesthetic and operating times equate to approximately $2586 saving/ case, given an estimate of $4000/hour of theatre costs. We conclude that pre-bending plates around 3D-printed life-size models of an individual's shoulder girdle prior to surgery results in approximately 38.8 mins time saving intra-op when used in shoulder arthrodesis. This is a viable and effective technique that will ultimately result in significant operative time and financial savings


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 46 - 46
1 Oct 2022
Porcellini G Giorgini A Montanari M
Full Access

Aim. Studies have shown that retention of antibiotic cement spacer in selected elderly patients with low functional demand represents a viable option for periprosthetic joint infections (PJI) treatment. 1,2. . The aim of this study is to compare the efficacy in infection treating among modular taylored preformed and hand-made antibiotic spacers. Our hypothesis is that modular tailored preformed spacer provides a better rate of infection resolution, better radiological and functional outcomes compared to hand-made spacers. Materials and methods. We identified 48 patients treated with antibiotic cement spacer for shoulder chronic infection between 2015 and 2021 in our institution; (13 hand-made spacers and 35 modular tailored preformed spacers). We collected data about comorbidities, associated microorganism, infection resolution, clinical and radiographic evaluation. Results. The mean age at surgery was 63.2 years, (45.8% female − 54.2% male), mean BMI 28.3. The mean time of infection diagnosis after first surgery was 30 months; (31.2% infection after ORIF in proximal humeral fractures, 68.8% PJI after shoulder arthroplasty). The main pathogens were Propionibacterium Acnes (37.5%), Staphylococcus Epidermidis (29.2%), Staphylococcus Aureus (16.7%), negative intraoperative coltures (14.6%), Enterococcus (4.17%), Pseudomonas Aeruginosa (4.17%). The mean time of antibiotic spacer retention was 18 months: 23 patients (47.9%) underwent second stage surgery for prosthesis implantation; 2 removed the spacer because of spacer dislocation, 2 died during follow up; while 21 patients still hold the antibiotic spacer (17 patients in treatment with prefabricated spacers and 4 with self-constructed spacer). The mean value for clinical assessment for patients with modular tailored preformed spacer were: Constant Score 34 – QuickDASH 40 – SST 33 – ASES Score 66 – VAS 2. Patients treated with hand-made spacer registered the following scores: Constant Score 20 – QuickDASH 51 – SST 25 – ASES Score 38 – VAS 6. Two patients presented fracture of the spacer (one hand-made spacer and one tailored preformed). Conclusions. According to our data patients treated with modular tailored preformed antibiotic spacer show better functional outcomes. Patients are more likely to retain the spacer as a permanent implant, avoiding the risks of a second stage surgery in those low-demanding patients, achieving a reasonable satisfying quality of shoulder motion without pain


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 71 - 71
24 Nov 2023
Heesterbeek P Pruijn N Boks S van Bokhoven S Dorrestijn O Schreurs W Telgt D
Full Access

Aim. Diagnosis of periprosthetic shoulder infections (PSI) is difficult as they are mostly caused by low-virulent bacteria and patients do not show typical infection signs, such as elevated blood markers, wound leakage, or red and swollen skin. Ultrasound-guided biopsies for culture may therefore be an alternative for mini-open biopsies as less costly and invasive method. The aim of this study was to determine the diagnostic value and reliability of ultrasound-guided biopsies for cultures alone and in combination polymerase chain reaction (PCR), and/or synovial markers for preoperative diagnosis of PSI in patients undergoing revision shoulder surgery. Method. A prospective explorative diagnostic cohort study was performed including patients undergoing revision shoulder replacement surgery. A shoulder puncture was taken preoperatively before incision to collect synovial fluid for interleukin-6 (IL-6), calprotectin, WBC, polymorphonuclear cells determination. Prior to revision surgery, six ultrasound-guided synovial tissue biopsies were collected for culture and two additional for PCR analysis. Six routine care tissue biopsies were taken during revision surgery and served as reference standard. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV; primary outcome measure), and accuracy were calculated for ultrasound-guided biopsies, and synovial markers, and combinations of these. Results. Fifty-five patients were included. In 24 patients, routine tissue cultures were positive for infection. Cultures from ultrasound-guided biopsies diagnosed an infection in 7 of these patients, yielding a sensitivity, specificity, PPV, NPV, and accuracy of 29.2%, 93.5%, 77.8%, 63.0%, and 65.6%, respectively. Ultrasound-guided biopsies in combination with synovial WBC increased the NPV to 76.7% and accuracy to 73.8%. When synovial WBC and calprotectin were combined with ultrasound-guided biopsies, it resulted in a better diagnostic value: sensitivity 69.2%, specificity 80.0%, PPV 69.2%, NPV 80.0%, and accuracy 75.8%. Ultrasound-guided biopsies in combination with calprotectin and ESR yielded a sensitivity of 50.0%, specificity of 93.8%, PPV of 80.0%, NPV of 78.9%, and accuracy of 79.2%. Synovial fluid was obtained in 42 patients. Sensitivities of WBC, PMN, IL-6, and calprotectin were between 25.0% and 35.7%, specificities between 89.5% and 95.0%, PPVs between 60.0% and 83.3%, NPVs between 65.4% and 69.4%, and accuracies between 64.5% and 70.6%. Conclusions. In this prospective study we showed that ultrasound-guided biopsies for cultures alone and in combination with PCR and/or synovial markers are not reliable enough to use in clinical practice for the preoperative diagnosis of low grade PSI


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 64 - 64
1 Mar 2010
Gortzak Y Mahendra A Griffin AM Wunder JS Ferguson PC
Full Access

Objectives: A stable shoulder is essential for proper elbow and hand function after oncologic resection of the shoulder girdle. We describe a surgical technique for replacing the shoulder joint capsule using synthetic mesh after resections of the shoulder girdle that resulted in gross intraoperative instability of the shoulder joint. Methods: 68 patients who underwent shoulder girdle resection between 1989 and 2006 were identified in our prospective database. This report focuses on nine patients whose shoulder joint was reconstructed with synthetic mesh. All patients were followed on a 3 monthly basis. Shoulder joint instability was determined from clinical records, database and radiographs. Results: Nine patients underwent shoulder joint reconstruction with synthetic mesh. One patient underwent a shoulder disarticulation within 30 days of the index surgery and was excluded from this rapport. No dislocations were noted during follow-up (range 3–48 months). Radiographs revealed an average vertical displacement of the humeral head compared to its original position of 0.7 cm (range 0–1.7 cm). There were two surgical complications. In one patient the humeral prosthesis migrated proximally and eroded through the skin requiring additional surgery. In another case erosion of the distal clavicle was noted. This was biopsied and foreign body reaction identified. Conclusions: Joint instability following major resections of the shoulder girdle is a source of morbidity and affects the function of the salvaged limb. Synthetic capsular reconstruction using Marlex mesh is a useful adjunct in patients where insufficient shoulder musculature and joint capsule remains after resection to allow for stable suspension of the upper limb


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 34 - 34
1 Nov 2021
Larsen JB Østergaard HK Thillemann TM Falstie-Jensen T Reimer L Noe S Jensen SL Mechlenburg I
Full Access

Introduction and Objective. Only few studies have investigated the outcome of exercises in patients with glenohumeral osteoarthritis (OA) or rotator cuff tear arthropathy (CTA), and furthermore often excluded patients with a severe degree of OA. Several studies including a Cochrane review have suggested the need for trials comparing shoulder arthroplasty to non-surgical treatments. Before initiation of such a trial, the feasibility of progressive shoulder exercises (PSE) in patients, who are eligible for shoulder arthroplasty should be investigated. The aim was to investigate whether 12 weeks of PSE is feasible in patients with OA or CTA eligible for shoulder arthroplasty. Moreover, to report changes in shoulder function and range of motion (ROM) following the exercise program. Materials and Methods. Eighteen patients (11 women, 14 OA), mean age 70 years (range 57–80), performed 12 weeks of PSE with 1 weekly physiotherapist-supervised and 2 weekly home-based sessions. Feasibility was measured by drop-out rate, adverse events, pain and adherence to PSE. Patients completed Western Ontario Osteoarthritis of the Shoulder (WOOS) score and Disabilities of the Arm, Shoulder and Hand (DASH). Results. Two patients dropped out and no adverse events were observed. Sixteen patients (89%) had high adherence to the physiotherapist-supervised sessions. Acceptable pain levels were reported. WOOS improved mean 23 points (95%CI:13;33), and DASH improved mean 13 points (95%CI:6;19). Conclusions. PSE is feasible, safe and may improve shoulder pain, function and ROM in patients with OA or CTA eligible for shoulder arthroplasty. PSE is a feasible treatment that may be compared with arthroplasty in a RCT setting


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 34 - 34
10 May 2024
Penumarthy R Turner P
Full Access

Aim. Clavicular osteotomy was described as an adjunct to deltopectoral approach for improved exposure of the glenohumeral joint. This study aims to present contemporary outcomes and complications associated with the routine use of clavicular osteotomy by a single surgeon in a regional setting within New Zealand. Methods. A retrospective case series of patients who have undergone any shoulder arthroplasty for any indication between March 2017 to August 2022. This time period includes all patients who had clavicular osteotomy(OS) and patients over an equal time period prior to the routine use of osteotomy as a reference group (N-OS). Oxford Shoulder Score (OSS) and a Simple Shoulder Test (STT) were used to assess functional outcomes and were compared with the reported literature. Operative times and Complications were reviewed. Results. 66 patients were included in the study. 33 patients in the OS group and 33 in the N-OS group. No difference in age, sex, indications for operative intervention and the surgery provided was identified. No significant difference in operative time between groups (N-OS 121 minutes; OS 128 minutes). No clinically significant difference was identified in the OSS (N-OS; mean 38 vs OS 39) or the STT (N-OS 8.3 vs OS 9). The outcomes scores of both groups are in keeping with published literature. Two post operative clavicle fractures, one prominent surgical knot occurred in the OS that required further surgical intervention. Two cases of localized pain over the clavicle and one case of the prominent lateral clavicle were reported in the OS group. Two cases of localized pain over clavicle reported in the N-OS group. Conclusion. Use of clavicular osteotomy is not associated with inferior patient reported. The osteotomy introduces specific risks, however, the study provides evidence that these complications are infrequent and avoidable. Surgeons should feel confident in using this adjunct when exposure to the shoulder is difficult


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 113 - 113
23 Feb 2023
Fang Y Ackerman I Harris I Page R Cashman K Lorimer M Heath E Graves S Soh S
Full Access

While clinically important improvements in Oxford Shoulder Scores have been defined for patients with general shoulder problems or those undergoing subacromial decompression, no threshold has been reported for classifying improvement after shoulder replacement surgery. This study aimed to establish the minimal clinically important change (MCIC) for the Oxford Shoulder Score in patients undergoing primary total shoulder replacement (TSR). Patient-reported outcomes data were sourced from the Australian Orthopaedic Association National Joint Replacement Registry Patient-Reported Outcome Measures Program. These included pre- and 6-month post-operative Oxford Shoulder Scores and a rating of patient-perceived change after surgery (5-point scale ranging from ‘much worse’ to ‘much better’). Two anchor-based methods (using patient-perceived improvement as the anchor) were used to calculate the MCIC: 1) mean change method; and 2) predictive modelling, with and without adjustment for the proportion of improved patients. The analysis included 612 patients undergoing primary TSR who provided pre- and post-operative data (58% female; mean (SD) age 70 (8) years). Most patients (93%) reported improvement after surgery. The MCIC derived from the mean change method was 6.8 points (95%CI 4.7 to 8.9). Predictive modelling produced an MCIC estimate of 11.6 points (95%CI 8.9 to 15.6), which reduced to 8.7 points (95%CI 6.0 to 12.7) after adjustment for the proportion of improved patients. For patient-reported outcome measures to provide valuable information that can support clinical care, we need to understand the magnitude of change that matters to patients. Using contemporary psychometric methods, this analysis has generated MCIC estimates for the Oxford Shoulder Score. These estimates can be used by clinicians and researchers to interpret important changes in pain and function after TSR from the patient's perspective. We conclude that an increase in Oxford Shoulder Scores of at least 9 points can be considered a meaningful improvement in shoulder-related pain and function after TSR


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 85 - 85
10 Feb 2023
Fang Y Ackerman I Harris I Page R Cashman K Lorimer M Heath E Graves S Soh S
Full Access

While clinically important improvements in Oxford Shoulder Scores have been defined for patients with general shoulder problems or those undergoing subacromial decompression, no threshold has been reported for classifying improvement after shoulder replacement surgery. This study aimed to establish the minimal clinically important change (MCIC) for the Oxford Shoulder Score in patients undergoing primary total shoulder replacement (TSR). Patient-reported outcomes data were sourced from the Australian Orthopaedic Association National Joint Replacement Registry Patient-Reported Outcome Measures Program. These included pre- and 6-month post-operative Oxford Shoulder Scores and a rating of patient-perceived change after surgery (5-point scale ranging from ‘much worse’ to ‘much better’). Two anchor-based methods (using patient-perceived improvement as the anchor) were used to calculate the MCIC: 1) mean change method; and 2) predictive modelling, with and without adjustment for the proportion of improved patients. The analysis included 612 patients undergoing primary TSR who provided pre- and post-operative data (58% female; mean (SD) age 70 (8) years). Most patients (93%) reported improvement after surgery. The MCIC derived from the mean change method was 6.8 points (95%CI 4.7 to 8.9). Predictive modelling produced an MCIC estimate of 11.6 points (95%CI 8.9 to 15.6), which reduced to 8.7 points (95%CI 6.0 to 12.7) after adjustment for the proportion of improved patients. For patient-reported outcome measures to provide valuable information that can support clinical care, we need to understand the magnitude of change that matters to patients. Using contemporary psychometric methods, this analysis has generated MCIC estimates for the Oxford Shoulder Score. These estimates can be used by clinicians and researchers to interpret important changes in pain and function after TSR from the patient's perspective. We conclude that an increase in Oxford Shoulder Scores of at least 9 points can be considered a meaningful improvement in shoulder-related pain and function after TSR


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 120 - 120
1 Mar 2008
MacDonald P Chahal J Berard H Kassiri K Dyck M
Full Access

Expert North American shoulder surgeons were poled on the diagnosis and treatment of five shoulder conditions. To quantify inter-observer agreement in the diagnosis and treatment of shoulder instabilities, they chose one of five diagnostic conditions and one or more of seven treatment options. The greatest diagnostic and treatment differences were noted for a painful shoulder in a throwing athlete with subtle anterior instability and a patient with voluntary posterior instability with an asymptomatic sulcus sign. An arthroscopic approach was consistently preferred to open surgery. These inconsistencies highlight the need for standardized diagnostic criteria and more universal treatment plans. To quantify inter-observer agreement in the diagnosis and treatment of shoulder instabilities among expert North American shoulder surgeons. These inconsistencies, particularly in diagnosis, highlight the need for standardization of diagnostic criteria and guidelines working towards more universal treatments and evaluations of outcomes. The greatest diagnostic differences were noted for a painful shoulder in a throwing athlete with subtle anterior instability(Ksc0.46, 55% agreement) and a patient with voluntary posterior instability with an asymptomatic sulcus sign(Ksc0.41, 50% agreement). The presence of an asymptomatic sulcus sign alone may have been mistakenly interpreted as inferior instability rather than inferior laxity. There was a high level of agreement in diagnosing anterior and bi-directional instability. An arthroscopic approach to treatment was consistently preferred to open surgery. The greatest differences in treatment choice were for the throwing athlete(Ksc0.38, 47% agreement on arthroscopic repair), a patient with voluntary posterior instability(Ksc0.34, 43% agreement on arthroscopic capsular repair) and a patient with bi-directional instability(Ksc0.23, 34% agreement on arthroscopic anterior Bankart repair). Active members of the American Shoulder and Elbow Surgeons and JOINTS Canada (Orthopaedic Initiatives for National Trials of the Shoulder) were poled on the diagnosis and treatment of five shoulder conditions. They were to choose one of five conditions and one or more of seven treatment options. A Kappa coefficient of agreement was used to assess inter-observer reliability; a Ksc of 1 denotes perfect agreement on a category and a Ksc of −1 denotes perfect agreement on not endorsing a category


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 82 - 82
1 Dec 2022
Hitchon S Milner J Holdsworth D Willing R
Full Access

Revision surgeries for orthopaedic infections are done in two stages – one surgery to implant an antibiotic spacer to clear the infection and another to install a permanent implant. A permanent porous implant, that can be loaded with antibiotics and allow for single-stage revision surgery, will benefit patients and save healthcare resources. Gyroid structures can be constructed with high porosity, without stress concentrations that can develop in other period porous structures [1] [2]. The purpose of this research is to compare the resulting bone and prosthesis stress distributions when porous versus solid stems are implanted into three proximal humeri with varying bone densities, using finite element models (FEM). Porous humeral stems were constructed in a gyroid structure at porosities of 60%, 70%, and 80% using computer-aided design (CAD) software. These CAD models were analyzed using FEM (Abaqus) to look at the stress distributions within the proximal humerus and the stem components with loads and boundary conditions representing the arm actively maintained at 120˚ of flexion. The stem was assumed to be made of titanium (Ti6Al4V). Three different bone densities were investigated, representing a healthy, an osteopenic, and an osteoporotic humerus, with an average bone shape created using a statistical shape and density model (SSDM) based on 75 cadaveric shoulders (57 males and 18 females, 73 12 years) [3]. The Young's moduli (E) of the cortical and trabecular bones were defined on an element-by-element basis, with a minimum allowable E of 15 MPa. The Von Mises stress distributions in the bone and the stems were compared between different stem scenarios for each bone density model. A preliminary analysis shows an increase in stress values at the proximal-lateral region of the humerus when using the porous stems compared to the solid stem, which becomes more prominent as bone density decreases. With the exception of a few mesh dependent singularities, all three porous stems show stress distributions below the fatigue strength of Ti-6Al-4V (410 MPa) for this loading scenario when employed in the osteopenic and osteoporotic humeri [4]. The 80% porosity stem had a single strut exceeding the fatigue strength when employed in the healthy bone. The results of this study indicate that the more compliant nature of the porous stem geometries may allow for better load transmission through the proximal humeral bone, better matching the stress distributions of the intact bone and possibly mitigating stress-shielding effects. Importantly, this study also indicates that these porous stems have adequate strength for long-term use, as none were predicted to have catastrophic failure under the physiologically-relevant loads. Although these results are limited to a single boney geometry, it is based on the average shape of 75 shoulders and different bone densities are considered. Future work could leverage the shape model for probabilistic models that could explore the effect of stem porosity across a broader population. The development of these models are instrumental in determining if these structures are a viable solution to combatting orthopaedic implant infections


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1717 - 1724
1 Nov 2021
Singh HP Haque A Taub N Modi A Armstrong A Rangan A Pandey R

Aims. The main objective of this study was to examine whether the Oxford Shoulder Score (OSS) demonstrated floor or ceiling effects when used to measure outcomes following shoulder arthroplasty in a large national cohort. Secondary objectives were to assess its pain and function subscales, and to identify independent predictors for patients achieving a postoperative ceiling score following shoulder arthroplasty. Methods. Secondary database analysis of the National Joint Registry (NJR), which included 48,270 patients undergoing shoulder arthroplasty, was conducted. The primary outcome measure was the OSS. Secondary outcome measures were the OSS-Function Component Subscale and OSS-Pain Component Subscale. Floor and ceiling effects were considered to be present if > 15% of patients scored either the lowest or highest possible score. Logistic regression analysis was used to identify independent predictors for scoring the highest possible OSS score postoperatively. Results. Preoperatively, 1% of patients achieved the lowest possible OSS score (0) and 0.4% of patients achieved the highest possible score (48). Postoperatively, < 1% of patients achieved the lowest score at all timepoints, but the percentage achieving the highest score at six months was 8.3%, at three years 16.9%, and at five years 17%. Male patients, those aged between 60 and 89 years, and those undergoing an anatomical total shoulder arthroplasty (ATSA) were more likely to contribute to the ceiling effect seen in the OSS questionnaire. Pain and function subscales exhibited greater ceiling effects at three years and five years when compared with the overall OSS questionnaire. Logistic regression analysis showed that sex, procedure type, and preoperative OSS score were independent predictors for scoring the highest possible OSS at years. Conclusion. Based on NJR patient-reported outcome measures data, the OSS does not exhibit a ceiling effect at six months, but does at three years and five years, in part due to outcome scores of ATSA. Preoperative OSS, age, male sex, and ATSA are independent predictors of achieving a ceiling score. Cite this article: Bone Joint J 2021;103-B(11):1717–1724


The Journal of Bone & Joint Surgery British Volume
Vol. 31-B, Issue 3 | Pages 426 - 432
1 Aug 1949
Simmonds FA

1. The "frozen" shoulder syndrome is due to an inflammatory lesion in the musculotendinous cuff invoked by a local area of degeneration. 2. The available evidence suggests that the primary site of the degenerative lesion is in the supraspinatus tendon. 3. Other causes of shoulder pain which must be differentiated from "frozen" shoulder are peritendinitis of the long head of biceps, degeneration or tears of the supraspinatus, and calcified deposits in the supraspinatus. 4. An explanation of the pathogenesis of lesions of the musculo-tendinous cuff is submitted in which the different types of clinico-pathological syndrome are correlated. This hypothesis is in accord with the experimental, clinical and operative findings


Bone & Joint Research
Vol. 13, Issue 8 | Pages 392 - 400
5 Aug 2024
Barakat A Evans J Gibbons C Singh HP

Aims. The Oxford Shoulder Score (OSS) is a 12-item measure commonly used for the assessment of shoulder surgeries. This study explores whether computerized adaptive testing (CAT) provides a shortened, individually tailored questionnaire while maintaining test accuracy. Methods. A total of 16,238 preoperative OSS were available in the National Joint Registry (NJR) for England, Wales, Northern Ireland, the Isle of Man, and the States of Guernsey dataset (April 2012 to April 2022). Prior to CAT, the foundational item response theory (IRT) assumptions of unidimensionality, monotonicity, and local independence were established. CAT compared sequential item selection with stopping criteria set at standard error (SE) < 0.32 and SE < 0.45 (equivalent to reliability coefficients of 0.90 and 0.80) to full-length patient-reported outcome measure (PROM) precision. Results. Confirmatory factor analysis (CFA) for unidimensionality exhibited satisfactory fit with root mean square standardized residual (RSMSR) of 0.06 (cut-off ≤ 0.08) but not with comparative fit index (CFI) of 0.85 or Tucker-Lewis index (TLI) of 0.82 (cut-off > 0.90). Monotonicity, measured by H value, yielded 0.482, signifying good monotonic trends. Local independence was generally met, with Yen’s Q3 statistic > 0.2 for most items. The median item count for completing the CAT simulation with a SE of 0.32 was 3 (IQR 3 to 12), while for a SE of 0.45 it was 2 (IQR 2 to 6). This constituted only 25% and 16%, respectively, when compared to the 12-item full-length questionnaire. Conclusion. Calibrating IRT for the OSS has resulted in the development of an efficient and shortened CAT while maintaining accuracy and reliability. Through the reduction of redundant items and implementation of a standardized measurement scale, our study highlights a promising approach to alleviate time burden and potentially enhance compliance with these widely used outcome measures. Cite this article: Bone Joint Res 2024;13(8):392–400


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 1 | Pages 118 - 122
1 Jan 1994
Huber H Gerber C

We reviewed 25 children who presented consecutively with voluntary (habitual) subluxation of the shoulder. Thirty-six shoulders were involved and symptoms had been present for an average period of 12 years. Eighteen children were managed by 'skillful neglect': all these had become fully active in the profession of their choice and were satisfied with the outcome. Two of them had required shoulder surgery in adult life but only after trauma. Seven children (ten shoulders) had undergone stabilising operations during childhood with the aim of preventing later degenerative arthritis. These patients were also active in their selected professions, but only three (five of the ten shoulders) had good results: two shoulders had recurrent instability, two were painful and one was stiff. None of the shoulders in either group had developed osteoarthritic changes. There was no association with emotional or psychiatric problems. We conclude that voluntary subluxation of the shoulder in children has a favourable prognosis and that there is no indication for surgical intervention during childhood


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 49 - 49
1 Sep 2012
Jain N Jesudason P Rajpura A Muddu B Funk L
Full Access

Introduction. There are over 110 special tests described in the literature for clinical examination of the shoulder, but there is no general consensus as to which of these are the most appropriate to use. Individual opinion appears to dictate clinical practice. Rationalising which tests and clinical signs are the most useful would not only be helpful for trainees, but would also improve day to day practice and promote better communication and understanding between clinicians. Methodology. We sent a questionnaire survey to all shoulder surgeons in the UK (BESS members), asking which clinical tests each surgeon found most helpful in diagnosing specific shoulder pathologies; namely sub-acromial impingement, biceps tendonitis, rotator cuff tears and instability; both anterior and posterior. Results. For impingement; Hawkins-Kennedy and Neer's tests were used by the majority of respondents, with 50% also routinely performing Neer's injection test. For frozen shoulder; the shoulder quadrant test was the commonest used, followed by loss of passive range of motion and loss of external rotation. For biceps tendonitis; Speed's and Yergason's tests were by far the commonest used. For rotator cuff tears the commonest signs were; the Napoleon belly press, Hornblower's sign, Gerber's sign, Jobe's sign and Codman's drop arm sign. For instability; the apprehension test, the Gerber-Ganz drawer test, load and shift test and Jobe's relocation test were the commonest used, with the jerk test also popular for posterior instability. We are also currently assessing how individuals actually perform these tests, and whether they are as the original authors described them. Conclusion. Our results demonstrated some variation in which tests were being used, but with an increased preference for certain tests. Interestingly a large number of respondents commented that the history was of paramount importance and that clinical signs should only substantiate the clinician's diagnosis


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 71 - 71
1 Dec 2022
Gazendam A Ekhtiari S Ayeni OR
Full Access

Orthopaedic surgeons prescribe more opioids than any other surgical speciality. Opioids remain the analgesic of choice following arthroscopic knee and shoulder surgery. There is growing evidence that opioid-sparing protocols may reduce postoperative opioid consumption while adequately addressing patients’ pain. However, there are a lack of prospective, comparative trials evaluating their effectiveness. The objective of the current randomized controlled trial (RCT) was to evaluate the efficacy of a multi-modal, opioid-sparing approach to postoperative pain management in patients undergoing arthroscopic shoulder and knee surgery. The NO PAin trial is a pragmatic, definitive RCT (NCT04566250) enrolling 200 adult patients undergoing outpatient shoulder or knee arthroscopy. Patients are randomly assigned in a 1:1 ratio to an opioid-sparing group or standard of care. The opioid-sparing group receives a three-pronged prescription package consisting of 1) a non-opioid prescription: naproxen, acetaminophen and pantoprazole, 2) a limited opioid “rescue prescription” of hydromorphone, and 3) a patient education infographic. The control group is the current standard of care as per the treating surgeon, which consists of an opioid analgesic. The primary outcome of interest is oral morphine equivalent (OME) consumption up to 6 weeks postoperatively. The secondary outcomes are postoperative pain scores, patient satisfaction, quantity of OMEs prescribed and number of opioid refills. Patients are followed at both 2 and 6 weeks postoperatively. Data analysts and outcome assessors are blinded to the treatment groups. As of December 1, 2021 we have enrolled 166 patients, reaching 83% of target enrolment. Based on the current recruitment rate, we anticipate that enrolment will be completed by the end of January 2022 with final follow-up and study close out completed by March of 2022. The final results will be released at the Canadian Orthopaedic Association Meeting in June 2022 and be presented as follows. The mean difference in OME consumption was XX (95%CI: YY-YY, p=X). The mean difference in OMEs prescribed was XX (95%CI: YY-YY, p=X). The mean difference in Visual Analogue Pain Scores (VAS) and patient satisfaction are XX (95%CI: YY-YY, p=X). The absolute difference in opioid refills was XX (95%CI: YY-YY, p=X). The results of the current study will demonstrate whether an opioid sparing approach to postoperative outpatient pain management is effective at reducing opioid consumption while adequately addressing postoperative pain in patients undergoing outpatient shoulder and knee arthroscopy. This study is novel in the field of arthroscopic surgery, and its results will help to guide appropriate postoperative analgesic management following these widely performed procedures


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 504 - 504
1 Dec 2013
Roche C Stroud N DiPaola M Flurin PH Zuckerman J Wright T
Full Access

Introduction. Initial fixation of noncemented implants is critical to achieve a stable bone/implant interface during the first few months after surgery to potentiate bone in-growth and avoid aseptic loosening. Numerous reverse shoulder glenoid implant designs have been conceived in an attempt to improve implant performance and decrease the rate of aseptic glenoid loosening, commonly reported to be 5%. Design variations include: baseplate profile, baseplate size, backside geometry, center of rotation, surface finish and coatings, fixation screw diameters, number of fixation screw options, and type of screw fixation. However, little comparative biomechanical data exist to substantiate one design consideration over another. To that end, this study quantified glenoid fixation before and after cyclic loading of simulated abduction of 6 different reverse shoulder glenoid designs when secured to a low density polyurethane bone substitute block. Methods. A displacement test quantified fixation of 6 different reverse shoulder designs: 38 mm Equinoxe standard offset (EQ), 38 mm Equinoxe lateral offset (EQL), 36 mm Depuy Delta III (DRS), 36 mm Zimmer, (ZRS), 32 mm neutral DJO RSP (DJO), and a 36 mm Tornier BIO-RSA (BIO), secured to a 0.24 g/cm. 3. polyurethane block as a shear (357 N) and compressive (50 N) load was applied before and after cyclic loading. (Figure 1) Glenoid displacement was measured relative to the block using dial indicators in the directions of the applied loads along the superior/inferior axis. A cyclic test rotated each glenosphere (n = 7 for each design) about a 55° arc of abduction at 0.5 Hz for 10k cycles as 750N was constantly applied. (Figure 2) Each implant was cycled using a 145° humeral liner of the appropriate diameter to ensure each device is subjected to the same shear load. A two-tailed unpaired student's t-test was used to compare pre- and post-cyclic mean displacements between designs; p < 0.05 denotes significance. Results. The average pre-cyclic displacement of the EQ, EQL, DRS, ZRS, DJO, and BIO devices was 181, 137, 186, 381, 238, 232 microns, respectively. The average post-cyclic displacement of the EQ, EQL, DRS, DJO, and BIO devices was 186, 129, 189, 368, 249 microns, respectively. During the cyclic test, 6 of 7 ZRS devices failed at an average of 2603 cycles, 1 of 7 DJO failed at 7342 cycles, and 4 of 7 BIO devices failed at an average of 2926 cycles. All 7 of the EQ, EQL, and DRS devices remained well fixed throughout cyclic loading. Discussion and Conclusions. The results of this study demonstrate significant difference in fixation associated 6 different reverse shoulder designs. Despite many similarities in geometry between these designs, significant differences in fixation were observed between nearly every implant design tested. This suggests that subtle changes in glenoid baseplate design can dramatically impact fixation, particularly in low density bone substitutes which are intended to simulate the bone quality of the recipient population for reverse shoulders. Future work should attempt to isolate which design parameters are the most critical contributors for initial fixation and ultimately, long-term stability


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 89 - 89
1 Oct 2022
Alier A Gasol B Pérez-Prieto D Santana F Torrens C
Full Access

Aim. A significant number of patients undergoing shoulder arthroplasty surgery have C acnes contamination at the end of the primary surgery. The objective of this study is to determine whether patients with C acnes contamination at the end of their primary shoulder surgery have a worse prognosis than those who end up without C. acnes contamination. Method. Prospective study including all patients who underwent a reverse shoulder prosthesis from January 2015 to December 2018. In all of them, 5 to 12 cultures were performed during primary surgery. The patients underwent surgery for shoulder arthritis secondary to rotator cuff tears, acute fracture of the proximal humerus, and sequelae of fracture of the proximal humerus. Exclusion criteria included the existence of previous surgeries on the affected shoulder, the presence of signs of infection, having received infiltrations and / or complementary invasive examinations (Arthro-MRI and Arthro-CT). Follow-up from 2 to 5 years. Functional assessment according to the Constant Functional Scale. All complications were also recorded. Results. 162 patients were included. Of these, 25 had positive cultures for C. acnes at the end of primary shoulder surgery. Average age of 74.8 years. 136 women and 26 men. 75.9% Shoulder arthritis secondary to rotator cuff tears, 13.6% acute fractures and 10.5% sequelae of fractures. There were no differences between patients with C. acnes and those without C. acnes regarding age and indication for surgery. Predominance of men in the group with positive C. acnes (p <0.001). No differences at 2 and 5 years in the Constant functional scale between the two groups (2 years, 59.6 vs 59.2 p 0.870) (5 years, 62.4 vs 59.5 p 0.360). Significant differences regarding the number of complications (p 0.001). Patients without C. acnes had 1 aseptic loosening of the metaglene and patients with C. acnes had 2 infections, 1 dislocation, and 1 revision surgery. Patients with contamination by C. acnes had more comorbidities (p 0.035) than patients without contamination. Conclusions. Patients with C acnes contamination at the end of primary surgery do not have functional differences when compared with patients without contamination at 2 and 5 years, but they have a higher number of complications in the medium term


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 98 - 98
1 Jan 2004
Freudmann M Hay S
Full Access

To discover how traumatic anterior shoulder dislocation in the young patient (17–25) is managed by shoulder surgeons in the UK. A comprehensive postal questionnaire was sent to 164 orthopaedic consultants, all members of BESS. Questions were asked about the initial reduction, investigations undertaken, timing of any surgery, preferred stabilization procedure, arthroscopic or open, detail of surgical technique, period of immobilization and rehabilitation programmes instigated in first-time and recur- rent traumatic dislocaters. The response rate was 82% (n=135). The most likely treatment of a young traumatic shoulder dislocation:. It will be reduced under sedation in A& E by the A& E doctor. Apart from x-ray, no investigations will be performed. It will be immobilised for 3 weeks, then given course of physiotherapy. Upon their second dislocation, they will be listed directly for an open Bankart procedure (with capsular shift as indicated) during which subscapularis will be detached and metallic bone anchors used. Following surgery, they will be immobilised for 3 to 4 weeks, before being permitted full range of movement at 2 to 3 months and allowed to return to contact sports at 6 to 12 months. On the other hand, 54% of surgeons indicated they would investigate prior to surgery, 18% said their first choice operation would be arthroscopic stabilisation, the number of dislocations normally permitted before surgery ranged from 1 to more than 4, and the period of immobilisation post operation from nil to 6 weeks. We now know how shoulder surgeons in the UK are treating this common injury. The results reveal that in Britain, we do not have a consistent approach, raising many discussion points. Open stabilisation remains the firm favourite. Does this mean arthroscopic stabilisation is regarded as an experimental procedure?


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_18 | Pages 9 - 9
1 Apr 2013
Kosy J Bradley BM Hawken R Ramesh R Conboy V
Full Access

The use of scoring systems for surveillance of post-operative outcomes is increasing. However, the methodology of this follow-up is not universal. We set out to assess whether a postal Oxford Shoulder Score (OSS) was sufficient to identify patients who were dissatisfied and wanted further treatment. Of 88 patients who had undergone GlobalCap resurfacing in the previous 5 years, we received a completed postal OSS (Median score 33, Range 5–48) from 80 patients. Those with a score <24 (an agreed threshold for surgery pre-operatively) were brought to clinic for review. The 16 recalled patients (2 males, 14 females; age 58–85) had their OSS repeated, supervised by a clinic nurse, and had a Constant Score and an American Shoulder and Elbow Surgeons (ASES) Score performed. Satisfaction was also questioned. OSS correlated well with the Constant Score (r=0.79) and ASES (r=0.86). However, supervision increased the OSS by an average of 6 points (Mean 13.9 to 19.9) and only three of the patients proved dissatisfied with the outcome of their surgery. Used alone, an unobserved OSS may have limited value for this purpose and the use of comparative pre-operative scores or additional patient-reported outcome measures may be necessary to detect poor outcomes


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 17 - 17
1 Dec 2021
Alier A Torrens C Bellosillo B Gibert J Pérez-Prieto D Corvec S
Full Access

Aim. Cutibacterium acnes (C. acnes) is the most cultured organism implicated in periprosthetic shoulder infections. Nevertheless, the clinical significance of its persistence on the skin surface and in the deep layers during shoulder arthroplasty surgery remains still unknown. The purpose of this study was to know if the C. acnes isolate present in deep tissues at the end of a primary shoulder arthroplasty could be responsible for shoulder arthroplasty infection. Method. Prospective study including 156 patients undergoing primary shoulder arthroplasty. In all the patients included 5 to 12 tissue samples were obtained and were specifically cultured to detect C. acnes presence. DNA was extracted from the C. acnes colonies selected with the QIAsymphony DSP Virus/Pathogen Midi Kit (Qiagen, Hilden, Germany). Libraries were prepared using Nextera XT kit (Illumina) and sequenced in an Illumina MiSeq sequencer. Sequencing files were pre-processed using The Microbial Genome Atlas pipeline. Samples that failed on QC analysis were discarded for further analysis. Isolate nucleotide distances were calculated using Genome-based distance matrix calculator from the enveomics collection. Comparative genomic analysis was performed between intra- and inter-patients’ isolates. Data analysis was performed using R 3.6.3. Results. For twenty-seven out of 156 patients (17.31%), C. acnes was present at the end of the primary surgery. Two of these patients (both male) developed a C. acnes periprosthetic shoulder infection after 6 and 4 months from the primary surgery. DNA from the C. acnes responsible for the periprosthetic infection was further analysed by whole genome sequencing (WGS). Average Nucleotide Identity (ANI) value was assessed, measuring the nucleotide-level genomic similarity between genome pairs. We found a clear ANI clustering in two major groups which corresponded, mainly, to the associated phylotype (97%–98% ANI). Moreover, when analysing both isolates that developed a periprosthetic shoulder infection, we found that all the revision-surgery isolates clustered nearer to their corresponding primary-surgery isolates (99.4% of similarity) than to the other independent bacterial isolates, supporting the causal relationship between the initial and the delayed infection. Conclusions. C. acnes present at the end of the primary surgery can be the cause of early- or delayed-periprosthetic joint infections in shoulder arthroplasty, revealing the potential route of infection. Therefore, efforts must be made in terms of antibiotic prophylaxis and skin preparation to limit infections of total shoulder arthroplasties


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 19 - 19
1 May 2012
A. M M. F S. H
Full Access

Aims. To discover how the management of traumatic anterior shoulder dislocation in the young patient (17-25) has changed, if at all, over the past six years. Methods. The same postal questionnaire was sent in 2002 and 2009 to 164 shoulder surgeons. Questions were asked about initial reduction, investigation undertaken, timing of surgery, preferred stabilisation procedure, period of immobilisation and rehabilitation programme instigated in first-time and recurrent traumatic dislocators. Summary of Results. Response rate - 92% (2009), 83% (2002). The most likely management of a young traumatic shoulder dislocation:. Reduction under sedation in A&E by A&E doctor (80%). Apart from X-ray, no investigations are performed (80%). Immobilisation for 3 weeks, followed by physiotherapy (82%). 68% would consider stabilisation surgery for first time dislocators (especially professional sportsmen) compared to 35% (2002). Of them, nearly 90% would perform an arthroscopic stabilisation vs. 57.5% (2002). For recurrent dislocators:. 75% would consider stabilisation after a second dislocation. 85% would investigate prior to surgery, choice of investigation being MR arthrogram (52%), compared to 50% (2002). 77% would perform arthroscopic stabilisation vs. 18% (2002), commonest procedure-arthroscopic Bankart repair using biodegradable bone anchors (62% 2009 vs. 27% in 2002). Immobilisation for 3 weeks, full range of motion 1-2 months and return to contact sports 6 - 12 months. Conclusion. There has been a remarkable change in practice compared to the previous survey. A significant proportion of Orthopaedic Surgeons would consider stabilisation in young first-time dislocators instead of conservative management. Arthroscopic stabilisation is now the preferred technique compared to open stabilisation whenever possible. Surgeons are using more investigations prior to listing the patient for surgery, namely the MR arthrogram. There is also an increased use of bio-degradable anchors as compared to metallic bone anchors in 2002


Bone & Joint 360
Vol. 11, Issue 5 | Pages 27 - 30
1 Oct 2022


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 191 - 191
1 Jul 2002
Oakley M Williams J
Full Access

The purpose of the study was to compare three shoulder scoring systems with the aim of assessing their ability to identify disability over a spectrum of disease within a routine shoulder practice. Considering our aims three systems were chosen for investigation; General Oxford Shoulder Questionnaire (GOSQ), Simple Shoulder Test Questionnaire (SST) and Hospital for Special Surgery System for Assessing Shoulder Function (HSS). Each was completed by 108 consecutive patients referred to our shoulder clinic, representing a spectrum of disease. These were compared with a pain and function score derived from the UK SF-36 Health Score. A subset of 27 patients repeated the questionnaires twenty four hours later to test repeatability of the scores. Agreement was calculated using Bland and Altman’s statistical method for assessing agreement between two methods of clinical measurement. This analysis was done both on the group as a whole and divided into five subgroups by diagnosis: instability (subgoup1), cuff tears and impingement (2), adhesive capsulitis (3), arthritis (4) and miscellaneous (5). Reproducibility as a standard deviation (SD) of the difference between the scores after 24 hours: HSS 9.9, GOSQ 8.8, SST, 15.5 and SF-36 11.1. Using the Bland and Altman method for assessing agreement, the scores both for repeatability and in comparison with the SF-36 are disappointing. It would appear that out of the three scores tested the HSS gives the most consistent results over a range of shoulder problems


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1600 - 1608
1 Dec 2018
Bouaicha S Ernstbrunner L Jud L Meyer DC Snedeker JG Bachmann E

Aims. In patients with a rotator cuff tear, tear pattern and tendon involvement are known risk factors for the development of pseudoparalysis of the shoulder. It remains unclear, however, why similar tears often have very different functional consequences. The present study hypothesizes that individual shoulder anatomy, specifically the moment arms (MAs) of the rotator cuff (RC) and the deltoid muscle, as well as their relative recruitment during shoulder abduction, plays a central role in pseudoparalysis. Materials and Methods. Biomechanical and clinical analyses of the pseudoparalytic shoulder were conducted based on the ratio of the RC/deltoid MAs, which were used to define a novel anatomical descriptor called the Shoulder Abduction Moment (SAM) index. The SAM index is the ratio of the radii of two concentric spheres based on the centre of rotation of the joint. One sphere captures the humeral head (numerator) and the other the deltoid origin of the acromion (denominator). A computational rigid body simulation was used to establish the functional link between the SAM index and a potential predisposition for pseudoparalysis. A retrospective radiological validation study based on these measures was also undertaken using two cohorts with and without pseudoparalysis and massive RC tears. Results. Decreased RC activity and improved glenohumeral stability was predicted by simulations of SAM indices with larger diameters of the humeral head, being consequently beneficial for joint stability. Clinical investigation of the SAM index showed significant risk of pseudoparalysis in patients with massive tears and a SAM < 0.77 (odds ratio (OR) 11). Conclusion. The SAM index, which represents individual biomechanical characteristics of shoulder morphology, plays a determinant role in the presence or absence of pseudoparalysis in shoulders with massive RC tears


Full Access

Introduction: Shoulder surface replacement arthroplasty has been established for several decades as a mean to restore comfort and function of the shoulder for many afflictions that derange the normal anatomy. The surface replacement may offer some advantages over the stemmed prostheses. Purpose: The purpose of the study was to evaluate the clinical and radiological results of Copeland cementless surface replacement arthroplasty (CSRA) applied in patients with a degenerative arthritis. Patients and Methods: The study was conducted on 76 patients with degenerative joint disease of the shoulder that were operated on between 1999 and 2006. The patients were prospectively followed up clinically and radiologically for a mean of 26.2 months (range, 9–80 months). There were 41 female and 35 male shoulders. The mean age was 64.4 years (range, 54–86). The mean operative time was 42 minutes (range, 27–62 minutes). The clinical assessment was performed with the Constant score Results: The constant score significantly improved from a mean of 16.32 points preoperatively to 68.72 points postoperatively. The average pain score increased from 0.2 points to 10.2 points. The average ROM score increased from 9.22 points to 24.73 points. The humeral offset increased from 24.2mm to 29.2mm. Conclusion: The shoulder surface replacement arthroplasty shows good mid-term results in patients with degenerative shoulder disease


Bone & Joint 360
Vol. 11, Issue 4 | Pages 25 - 29
1 Aug 2022


Bone & Joint Research
Vol. 8, Issue 8 | Pages 357 - 366
1 Aug 2019
Lädermann A Tay E Collin P Piotton S Chiu C Michelet A Charbonnier C

Objectives. To date, no study has considered the impact of acromial morphology on shoulder range of movement (ROM). The purpose of our study was to evaluate the effects of lateralization of the centre of rotation (COR) and neck-shaft angle (NSA) on shoulder ROM after reverse shoulder arthroplasty (RSA) in patients with different scapular morphologies. Methods. 3D computer models were constructed from CT scans of 12 patients with a critical shoulder angle (CSA) of 25°, 30°, 35°, and 40°. For each model, shoulder ROM was evaluated at a NSA of 135° and 145°, and lateralization of 0 mm, 5 mm, and 10 mm for seven standardized movements: glenohumeral abduction, adduction, forward flexion, extension, internal rotation with the arm at 90° of abduction, as well as external rotation with the arm at 10° and 90° of abduction. Results. CSA did not seem to influence ROM in any of the models, but greater lateralization achieved greater ROM for all movements in all configurations. Internal and external rotation at 90° of abduction were impossible in most configurations, except in models with a CSA of 25°. Conclusion. Postoperative ROM following RSA depends on multiple patient and surgical factors. This study, based on computer simulation, suggests that CSA has no influence on ROM after RSA, while lateralization increases ROM in all configurations. Furthermore, increasing subacromial space is important to grant sufficient rotation at 90° of abduction. In summary, increased lateralization of the COR and increased subacromial space improve ROM in all CSA configurations. Cite this article: A. Lädermann, E. Tay, P. Collin, S. Piotton, C-H Chiu, A. Michelet, C. Charbonnier. Effect of critical shoulder angle, glenoid lateralization, and humeral inclination on range of movement in reverse shoulder arthroplasty. Bone Joint Res 2019;8:378–386. DOI: 10.1302/2046-3758.88.BJR-2018-0293.R1


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 21 - 21
1 Jul 2020
Yew B Cheng J Choh A Yew A Lie D Chou S
Full Access

The function of the shoulder joint has traditionally been evaluated based on range of motion (ROM) in predefined anatomical planes and also by using functional scores, which assessed shoulder function based on the ability to conduct certain activities of daily living (ADLs). However, measuring ROM only in terms of flexion-extension, abduction-adduction and internal-external rotation may under-account for the 3-dimensional mobility of the shoulder joint. Furthermore, functional scores, such as the Oxford shoulder score or American shoulder and elbow surgeons (ASES) score, are subjective measures and are not an accurate assessment of shoulder joint function. In this study, we proposed the use of the globe model of the shoulder joint which can be used to provide an objective measure of the global ROM and also function of the shoulder joint – termed the Global and Functional arc of motion (GAM and FAM). Thirty-three young, healthy male patients (23.7 ± 1.5 years) were recruited and tasked to perform eight ADLs and a full humeral circumduction movement which represented their active global ROM. Reflective markers were placed in accordance to the International Society of Biomechanics (ISB) and optical-based motion capture cameras were used to track relative motion of the dominant humerus with respect to the thorax (i.e. thoracohumeral motion). The GAM and FAM were generated by plotting the thoracohumeral on a spherical coordinate system during global ROM and the eight ADLs respectively. Shoulder joint global ROM and function were quantified by calculating the area enclosed by the closed loop of GAM and FAM respectively. The spherical coordinate system, or more commonly referred to as the globe model, describes thoracohumeral movement using plane of elevation (POE), angle of elevation (AOE) and rotation. In our model, POE and AOE represents longitude and latitude of the globe respectively, and rotation is depicted using a red-green-blue (RGB) colour scale. Overall, subject's GAM of the shoulder joint covered an area of 4.64 ± 0.48 units2 compared to only 1.12 ± 0.26 units2 for the FAM. Subjects only required 24.4 ± 5.7 % of their global shoulder ROM for basic daily functioning. Studies that reduced shoulder joint movement into planar movements (i.e. sagittal, coronal and rotation) do not account for the 3-dimensional nature of the joint and doing so may overestimate the requirement of the shoulder joint for ADLs relative to its ROM in each plane. While others have attempted to use the globe model, such studies tend to reduce the globe into its descriptive angles (i.e. POE, AOE and rotation), reducing its intuitiveness. In contrast, by keeping an intact globe, the proposed globe model was more intuitive and yet capable of quantifying both shoulder joint global ROM and function. Doing so, we found that young healthy subjects only required approximately a quarter of their global ROM of the shoulder joint to complete the most common daily tasks, which was significantly less than what was previously reported


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 102 - 102
1 May 2011
Malhotra A Freudmann M Hay S
Full Access

Aims: To discover how the management of traumatic anterior shoulder dislocation in the young patient (17–25) has changed, if at all, over the past six years. Methods: The same postal questionnaire was used in 2003 and 2009, sent out to 164 members of British Elbow and Shoulder Society. Questions were asked about the initial reduction, investigation undertaken, timing of any surgery, preferred stabilization procedure, arthroscopic or open, detail of surgical technique, period of immobilization and rehabilitation programme instigated in first-time and recurrent traumatic dislocators. Summary of Results: The response rate were 92% (n=151) – 2009, 83% (n=131) – 2003 The most likely management of a young traumatic shoulder dislocation in the UK would be:. Reduction under sedation in A& E by the A& E doctor (80% of respondents). Apart from X-ray, no investigations are performed (80%). Immobilisation for 3 weeks, followed by physiotherapy (82%). 68 % of respondents would consider stabilisation surgery for first time dislocators (especially professional sportsmen) compared to 35% in 2003. Out of them nearly 90% would perform an arthroscopic stabilization vs. 57.5% in 2003. For recurrent dislocators:. 75% would consider stabilisation after a second dislocation. 85% would investigate prior to surgery, choice of investigation being MR arthrogram (52%), compared to 50% in 2003 that would chose to investigate. 77% would choose to perform arthroscopic stabilisation compared to 18% in 2003, the commonest procedure being arthroscopic Bankart repair using biodegradable bone anchors (62% compared to 27% in 2003). Following surgery, immobilisation would be for 3 weeks, full range of motion at 1 to 2 months and return to contact sports at 6 to 12 months. Conclusions: There has been a remarkable change in practice compared to the previous survey. A significant proportion of Orthopaedic Surgeons would consider stabilisation in young first time dislocators instead of conservative management. Arthroscopic stabilisation is now the preferred technique compared to open stabilisation whenever possible. Surgeons are using more investigations prior to listing the patient for surgery namely the MR arthrogram. There is also an increased use of bio-degradable anchors as compared to metallic bone anchors in 2003


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 73 - 73
1 Jul 2020
Yeoh J Chin P Regan WD Lim B Sasyniuk T Sayre E
Full Access

Glenoid failure remains the most common mode of total shoulder arthroplasty failures. Porous tantalum metal (Trabecular Metal™, Zimmer) have grown in popularity in hip and knee arthroplasty. First-generation porous tantalum metal-backed glenoid components demonstrated metal debris, resulted in failure, and were revised to second-generation glenoid implants. Evidence for second-generation porous tantalum metal implants in shoulder arthroplasty is sparse.1–4 The purpose of this study was to assess clinical and radiographic outcomes in a series of patients with second-generation porous tantalum glenoid components at a minimum two-years postoperative. We retrospectively reviewed the clinical and radiographic outcomes of patients who received a second-generation porous tantalum glenoid component anatomic shoulder arthroplasty between May 2009 and December 2017 with minimum 24 months follow-up. The shoulder arthroplasties were performed by one of two senior fellowship-trained surgeons. We collected postoperative clinical outcome indicators: EQ5D visual analog scale (VAS), Western Ontario Osteoarthritis of the Shoulder (WOOS) Index, American Shoulder and Elbow Surgeons (ASES) Score, and Constant Score (CS). Radiographic review was performed by an independent fellowship-trained surgeon. The Endrizzi metal debris grading system1 was utilized to grade metal debris. We computed descriptive statistics and compared outcome scores between groups via the non-parametric Wilcoxon rank-sum test, with group-wise comparisons defined by: metal debris and humeral head migration (secondary analyses). Thirty-five patients [23 male (65.7%) and 12 female (34.3%)] with 40 shoulder replacements participated in the study. Forty of 61 shoulders (65.6%) had an average of 64 ± 20.3 months follow-up (range 31 to 95). Average BMI was 27.5 ± 4.4 kg/m2 (range 19.5 to 39.1). The average postoperative EQ5D VAS at final follow-up was 74.6 ± 22.5, WOOS Index 87.9 ± 16.6, ASES Score 88.3 ± 10.9, and CS 80.4 ± 13. At final follow-up, 18 of 40 shoulders (45%) had metal debris [15 of 40 (37.5%) Endrizzi grade 1 and three of 40 (7.5%) Endrizzi grade 2], and 22 of 40 shoulders (55%) did not show evidence of metal debris. There was one non-revision reoperation (open subscapularis exploration), one shoulder with anterosuperior escape, three shoulders with glenoid radiolucencies indicative of possible glenoid loosening, and nine shoulders with superior migration of the humeral head (>2mm migration at final follow-up compared to immediate postoperative). When comparing postoperative scores between patients with vs without metal debris, we found no statistically significant difference in the EQ5D VAS, WOOS Index, ASES Score and CS. On further analyses, when comparing superior migration of the humeral head and postoperative outcomes scores, we found no statistically significant difference. We report the longest published follow-up with clinical and radiographic outcomes of second-generation porous tantalum glenoid anatomic shoulder arthroplasties. In this series of patients, 45% of total shoulder arthroplasties with a second-generation porous tantalum glenoid implant had radiographic evidence of metal debris. This metal debris was not statistically associated with poorer postoperative outcomes. Further investigation and ongoing follow-up are warranted


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 54 - 54
1 Mar 2017
Levy J Kurowicki J Triplet J
Full Access

Background. Locked anterior shoulders (LAS) with static instability and anterior glenoid bone loss are challenging in the elderly population. Reverse shoulder arthroplasty (RSA) has been employed in treating these patients. No study has compared RSA for LAS to classically indicated RSA. Methods. A case-control study of patients treated with RSA for LAS with glenoid bone loss and static instability was performed using matched controls treated with primary RSA for classic indications. Twenty-four cases and 48 controls were evaluated. Average follow-up was 25.5 months and median age was 76. Motion, outcome assessments, and postoperative radiographs were compared. Results. Preoperatively, LAS had significantly less rotation and lower baseline outcome scores. Glenoid bone grafting was more common (p=0.05) in control group (26%) than LAS group (6.3%). Larger glenospheres were utilized more often (p=0.001) in LAS group (75%) than control group (29%). Both groups demonstrated significant improvements in pain, function, and outcome scores. Postoperatively, control group had significantly better elevation and functional outcome scores. With the exception of flexion and SST, effectiveness of treatment was similar between groups. Postoperative acromion stress fractures were seen in 21% of LAS and 9% of control (p=0.023) with a predominance of type 3 fractures in LAS. Two LAS patients remained dislocated. Conclusion. Treatment with RSA for LAS may anticipate improvements in pain and function using larger glenospheres often without the need for glenoid bone grafting. Worse postoperative motion, function, and a higher incidence of acromion stress fracture may be expected


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 157 - 167
1 Jan 2022
Makaram NS Goudie EB Robinson CM

Aims. Open reduction and plate fixation (ORPF) for displaced proximal humerus fractures can achieve reliably good long-term outcomes. However, a minority of patients have persistent pain and stiffness after surgery and may benefit from open arthrolysis, subacromial decompression, and removal of metalwork (ADROM). The long-term results of ADROM remain unknown; we aimed to assess outcomes of patients undergoing this procedure for stiffness following ORPF, and assess predictors of poor outcome. Methods. Between 1998 and 2018, 424 consecutive patients were treated with primary ORPF for proximal humerus fracture. ADROM was offered to symptomatic patients with a healed fracture at six months postoperatively. Patients were followed up retrospectively with demographic data, fracture characteristics, and complications recorded. Active range of motion (aROM), Oxford Shoulder Score (OSS), and EuroQol five-dimension three-level questionnaire (EQ-5D-3L) were recorded preoperatively and postoperatively. Results. A total of 138 patients underwent ADROM; 111 patients were available for long-term follow-up at a mean of 10.9 years (range 1 to 20). Mean age was 50.8 years (18 to 75);79 (57.2%) were female. Mean time from primary ORPF to ADROM was 11.9 months (6 to 19). Five patients developed superficial wound infection; ten developed symptomatic osteonecrosis/post-traumatic arthrosis (ON/PTA); four underwent revision arthrolysis. Median OSS improved from 17 (interquartile range (IQR) 12.0 to 22.0) preoperatively to 40.0 (IQR 31.5 to 48.0) postoperatively, and 39.0 (IQR 31.5 to 46.5) at long-term follow-up (p < 0.001). Median EQ-5D-3L improved from 0.079 (IQR -0.057 to 0.215) to 0.691 (IQR 0.441 to 0.941) postoperatively, and 0.701 (IQR 0.570 to 0.832) at long-term follow-up (p < 0.001). We found that aROM improved in all planes (p < 0.001). Among the variables assessed on multivariable analysis, a manual occupation, worsening Charlson Comorbidity Index and increasing socioeconomic deprivation were most consistently predictive of worse patient-reported outcome scores. Patients who subsequently developed ON/PTA reported significantly worse one-year and late OSS. Conclusion. ADROM in patients with persistent symptomatic stiffness following ORPF can achieve excellent short- and long-term outcomes. More deprived patients, those in a manual occupation, and those with worsening comorbidities have worse outcomes following ADROM. Cite this article: Bone Joint J 2022;104-B(1):157–167


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 22 - 22
1 Apr 2019
Ramos A Bola M Simoes JA
Full Access

Introduction. Shoulder arthoplasty has increased in the last years and its main goal is to relieve pain and restore function. Shoulder prosthesis enters in the market without any type of pre-clinical tests. Within this paper we present study experimental and computational tests as pre-clinical testing to evaluate total shoulder arthoplasty performance. Materials and methods. An in vitro experimental simulator was designed to characterize experimentally the intact and implanted shoulder glenoid articulation. Fourth generation Sawbones® composite left humerus and scapula were used and the cartilage was replicated with silicone for the intact articulation (figure 1). In the intact experimental articulation we considered the inferior glenohumeral ligament as an elastic band with equivalent mechanical properties. For the implanted shoulder, the Comprehensive® Total Shoulder System (Biomet®) with a modular Hybrid® glenoid base and Regenerex® central post was considered (figure 2). The prostheses were implanted by an experienced surgeon and clinical results from orthopedic registers were collected. The system structures were placed to simulate 90º in abduction, including the following muscle forces: Deltoideus 300N, Infraspinatus 120N, Supraspinatus 90N and Subscapularis 225N. The finite element model was created with tetrahedral linear elements with linear elastic and isotropic material for the humerus in figure 3, (Young's modulus for cortical bone − 16.5 GPa; trabecular bone − 124 MPa). Anisotropic behavior was considered for the scapula model (E11 = 342.1 MPa, E22 = 212.8 MPa, E33 = 194.4 MPa). The shoulder prosthesis was of polyethylene with 1GPa and titanium with 110 GPa. The Poisson's ratio was 0.3 in all material, except for polyethylene where we assumed a value of 0.4. A long-term post-operative condition was simulated. Results. The experimental results were compared with numerical ones for model validation. The strains measured evidence the effect of the implant presence, manly in the scapula. In the anterior region presents an increase of strains (+26%) was observed for the anterior region and decrease (−52%) in the posterior region, suggesting strain shielding in figure 4. At the glenoid cavity, the numerical principal strains present safety values of strains (200 to 2500) µε in both axial and coronal planes. This indicates that on the long-term the glenoid prosthesis is well fixed to the surrounding bone tissue and bone integrity is maintained despite the presence of the implant. However there are some peak values (2500, 25 000 µε) that were observed in some small areas in the posterior and distal regions. Results were compared with clinical ones. Discussion and Conclusions. The proposed pre-clinical test with the articulation at 90º in abduction can predict bone behavior when total shoulder prosthesis is implanted and in the long term post-operative condition. The results obtained evidence some critical regions around the glenoid component. This pre-clinical test can be implemented to improve the concepts before market


Bone & Joint 360
Vol. 11, Issue 3 | Pages 29 - 32
1 Jun 2022


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 140 - 140
1 Apr 2005
Trojani C Boileau P Coste J Walch G
Full Access

Purpose: The purpose of this work was to evaluate the quality of cemented humeral stem fixation. We analysed the incidence and influence of humeral lucent lines and loosening after implantation of a shoulder prosthesis as a function of aetiology (fracture versus scapular osteoarthritis) and glenoid status (total versus partial humeral prosthesis). Material and methods: This retrospective series included 1842 first-intention shoulder prostheses reviewed at mean five years (2–10). We selected patients whose initial diagnosis was fracture of the superior portion of the humerus (n=300) and centred osteoarthritis (n=767). All stems implanted for fracture were cemented. For osteoarthritis, there were 610 total prostheses and 157 simple humeral prostheses: 752 stems were cemented and 15 were implanted without cement. The Constant score and radiographic results (AP and lateral view at least) were noted. Results: For cemented stems, the incidence of radiographic lucent lines and loosening was significantly higher in fractures (40% and 10% respectively) than in centred osteoarthritis (14% and 1%). Lucency and loosening did not influence functional outcome in patients with centred osteoarthritis but had a significantly negative effect on final outcome in fractures. For fractures, the incidence of lucent lines was correlated with migration of the tubercles. For osteoarthritis, there was no difference between total and partial prostheses in terms of loosening, but the functional outcome was significantly better with total prostheses. Conclusion: Fixation of the humeral implant with cement remains the gold standard for shoulder prostheses implanted for centred osteoarthritis. However, cement fixation yields disappointing results for fractures: defective fixation of the humeral stem is correlated with migration of the tubercles. For osteoarthritis, there are not more lucent lines with a total prosthesis which provides the better functional results


Abstract. Objective. Radial to axillary nerve and spinal accessory (XI) to suprascapular nerve (SSN) transfers are standard procedures to restore function after C5 brachial plexus dysfunction. The anterior approach to the SSN may miss concomitant pathology at the suprascapular notch and sacrifices lateral trapezius function, resulting in poor restoration of shoulder external rotation. A posterior approach allows decompression and visualisation of the SSN at the notch and distal coaptation of the medial XI branch. The medial triceps has a double fascicle structure that may be coapted to both the anterior and posterior division of the axillary nerve, whilst preserving the stabilising effect of the long head of triceps at the glenohumeral joint. Reinnervation of two shoulder abductors and two external rotators may confer advantages over previous approaches with improved external rotation range of motion and strength. Methods. Review of the clinical outcomes of 22 patients who underwent a double nerve transfer from XI and radial nerves. Motor strength was evaluated using the MRC scale and grade 4 was defined as the threshold for success. Results. 18/22 patients had adequate follow-up (Mean: 29.5 months). Of these, 72.2% achieved ≥grade 4 power of shoulder abduction and a mean range of motion of 103°. 64.7% achieved ≥grade 4 external rotation with a mean range of motion of 99.6°. Conclusions. The results suggest the use of the combined nerve transfer for restoration of shoulder function via a posterior approach, involving the medial head branch of triceps to the axillary nerve and the XI to SSN


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 131 - 131
1 Jul 2002
Zehetgruber H Wurnig C
Full Access

The aim of this study was to evaluate how three different scoring systems (Constant, Reichelt, and UCLA scores) perform in individuals with normal shoulder function. Scoring systems to evaluate the outcome of surgical treatment around the shoulder are well established. A total of 201 individuals were enrolled in this study. They were divided in four age groups and divided by sex: Group 1: Under 50 years of age: 25 female, 21 male; Group II: From 50 to 59 years of age: 17 female, 21 male; Group III: From 60 to 69 years of age: 18 female, 12 male; Group IV: 70 years of age and older: 24 female, 15 male. All underwent clinical examination, ultrasound examination for detection of cuff tears, and radiograph examination in three planes. In all cases the dominant arm was enrolled. Twelve patients were excluded from the study because ultrasound depicted cuff tear or radiograph showed more than mild osteoarthritis according to the criteria of Hawkins, et al. (1990). The main factor influencing the over-all score was the age-dependent decrease of muscle force measured in forward arm flexion (max. 12.5kp). The score was also influenced by the limitation of internal rotation (Group I: 13%, Group II: 26%, Group III: 40%, Group IV: 41%). According to the Reichelt and UCLA scores, males in Groups I, II and III reached a 100% top score in the UCLA and Reichelt scoring systems. In Group IV composed of older male patients, 20% scored less that the top score because of loss in active motion and muscle force. Only females in Groups I and II scored maximum results. Females in Group III scored 11% and in Group IV composed of older female patients, 50% scored less than the top score because of loss in active motion and muscle force. Due to the natural aging process, males and females in Group IV could not accomplish maximum scores. We recommend that the top scores for the oldest age group be adjusted in order to avoid drawing erroneous conclusions from the scores in this age group


Bone & Joint 360
Vol. 11, Issue 2 | Pages 31 - 34
1 Apr 2022


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 48 - 48
1 Aug 2020
Burns D
Full Access

Participation in a physical therapy program is considered one of the greatest predictors for successful conservative management of common shoulder disorders, however, adherence to standard exercise protocols is often poor (around 50%) and typically worse for unsupervised home exercise programs. Currently, there are limited tools available for objective measurement of adherence and performance of shoulder rehabilitation in the home setting. The goal of this study was to develop and evaluate the potential for performing home shoulder physiotherapy monitoring using a commercial smartwatch. We hypothesize that shoulder physiotherapy exercises can be classified by analyzing the temporal sequence of inertial sensor outputs from a smartwatch worn on the extremity performing the exercise. Twenty healthy adult subjects with no prior shoulder disorders performed seven exercises from a standard evidence-based rotator cuff physiotherapy protocol: pendulum, abduction, forward elevation, internal/external rotation and trapezius extension with a resistance band, and a weighted bent-over row. Each participant performed 20 repetitions of each exercise bilaterally under the supervision of an orthopaedic surgeon, while 6-axis inertial sensor data was collected at 50 Hz from an Apple Watch. Using the scikit-learn and keras platforms, four supervised learning algorithms were trained to classify the exercises: k-nearest neighbour (k-NN), random forest (RF), support vector machine classifier (SVC), and a deep convolutional recurrent neural network (CRNN). Algorithm performance was evaluated using 5-fold cross-validation stratified first temporally and then by subject. Categorical classification accuracy was above 94% for all algorithms on the temporally stratified cross validation, with the best performance achieved by the CRNN algorithm (99.4± 0.2%). The subject stratified cross validation, which evaluated classifier performance on unseen subjects, yielded lower accuracies scores again with CRNN performing best (88.9 ± 1.6%). This proof-of concept study demonstrates the feasibility of a smartwatch device and machine learning approach to more easily monitor and assess the at-home adherence of shoulder physiotherapy exercise protocols. Future work will focus on translation of this technology to the clinical setting and evaluating exercise classification in shoulder disorder populations


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 27 - 27
1 Mar 2008
Freudmann M Hay S
Full Access

A comprehensive postal questionnaire was sent to 164 orthopaedic consultants, all members of the Brit-ish Elbow and Shoulder Society. Questions were asked about the initial reduction, investigations undertaken, timing of any surgery, preferred stabilization procedure, arthroscopic or open, detail of surgical technique, period of immobilization and rehabilitation programmes instigated in first-time and recurrent traumatic dislocators. The response rate was 83% (n=136). The most likely treatment of a young traumatic shoulder dislocation:. It will be reduced under sedation in A& E by the A& E doctor. Apart from x-ray, no investigations will be performed. It will be immobilised for 3 weeks, then given course of physiotherapy. Upon their second dislocation, they will be listed directly for an open Bankart procedure (with capsular shift as indicated) during which subscapularis will be detached and metallic bone anchors used. Following surgery, they will be immobilised for 3 to 4 weeks, before being permitted full range of movement at 2 to 3 months and allowed to return to contact sports at 6 to 12 months. On the other hand, 54% of surgeons indicated they would investigate prior to surgery, 16% said their first choice operation would be arthroscopic stabilisation, the number of dislocations normally permitted before surgery ranged from 1 to more than 3, and the period of immobilisation post operation from nil to 6 weeks. The results reveal a wide variation in practice and no clear consensus on how to best manage these patients. Open stabilisation remains the firm favourite. Does this mean arthroscopic stabilisation is regarded as an experimental procedure?


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 520 - 526
1 Apr 2015
Roberts SB Beattie N McNiven ND Robinson CM

The natural history of primary anterior dislocation of the glenohumeral joint in adolescent patients remains unclear and there is no consensus for management of these patients. The objectives of this study were to report the natural history of primary anterior dislocation of the glenohumeral joint in adolescent patients and to identify the risk factors for recurrent dislocation. We reviewed prospectively-collected clinical and radiological data on 133 adolescent patients diagnosed with a primary anterior dislocation of the glenohumeral joint who had been managed non-operatively at our hospital between 1996 and 2008. There were 115 male (86.5%) and 18 female patients (13.5%) with a mean age of 16.3 years (13 to 18) and a mean follow-up of 95.2 months (1 to 215). During follow-up, 102 (absolute incidence of 76.7%) patients had a recurrent dislocation. The median interval between primary and recurrent dislocation was ten months (95% CI 7.4 to 12.6). Applying survival analysis the likelihood of having a stable shoulder one year after the initial injury was 59% (95% CI 51.2 to 66.8), 38% (95% CI 30.2 to 45.8%) after two years, 21% (95% CI 13.2 to 28.8) after five years, and 7% (95% CI 1.1 to 12.9) after ten years. Neither age nor gender significantly predicted recurrent dislocation during follow-up. We conclude that adolescent patients with a primary anterior dislocation of the glenohumeral joint have a high rate of recurrent dislocation, which usually occurs within two years of their initial injury: these patients should be considered for early operative stabilisation. Cite this article: Bone Joint J 2015;97-B:520–6


Bone & Joint 360
Vol. 11, Issue 1 | Pages 32 - 35
1 Feb 2022


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 509 - 510
1 Aug 2008
Arzi H Perri M Krasovsky T Liebermann D
Full Access

Background: After shoulder surgery for joint stabilization, patients often report that shoulder function improves and positive signs in the ‘apprehension test’ disappear. However, objective validation of the outcomes of shoulder surgery has never been provided. We inquired first about the characteristics of arm movements in healthy individuals and found that in the literature that healthy 2D motion of the arm (e.g., movements performed on table) tend to be smooth and follow shortest amplitude paths with symmetric and unimodal tangential velocity profiles (Minimum Jerk model; Flash and Hogan 1985). In this study, we assumed that such smoothness criterion could be used as an objective indicator of healthy arm movements also in 3D, and thus, we compared the motor outcome before and after different but common surgical procedures for shoulder stabilization (arthroscopy versus open surgery). Methods: Data were obtained from 3 consecutive point-to-point arm movement trials carried out in each of 3 speed conditions (fast, preferred, slow) and 4 different targets locations towards one central target above the head (Speeds and Movement Directions were repeated measures while Groups were the between-subjects factor). Trials were collected from 14 healthy control subjects (group C), 11 patients before surgery (group B), 3 patients after arthroscopy for stabilization of the shoulder (group A) and 10 patients that underwent open surgery (group D). 3D data were captured by a motion tracking system at a rate of 100 Hz from reflective markers attached to the right arm (acromion and the distal end of the humerus). The kinematic data were pre-processed using MatLab routines. Statistical analyses were based on the following objective measures of smoothness: Time-to-peak speed (TT P), peak-to-mean amplitude ratio (PAR), speed similarity index (SSI) and number of peaks in the tangential velocity of the arm (NO P). Descriptive statistics and multiple 2-way ANO VAs were carried out using these dependent variables (p< 0.05). Results: Significant effects of the Group factor were observed in the ANOVAs using TT P, PAR and NOP as dependent variables, but not SSI. Post hoc comparisons showed that Group A differed significantly from all others. Patients in group D did not significantly differed from healthy subjects (group C), but patients before surgery (group B) differed from all others. Notably, patients after arthroscopy were also closer to the maximal smoothness scores predicted by the minimum jerk model than even healthy subjects. Discussion: The results show that kinematics measures may be used to objectively assess the success of one surgical procedure over another. The maximal smoothness criterion seems to be a sensitive measure describing shoulder performance, and thus, parameters derived from this assumption allow for a discrimination of healthy motion from pathological motion. As it stems from the current study, arthroscopy seems to be the preferable intervention since objective measures of smoothness showed that these patients outperform others after surgery. A test of based on slow movement may enhance these differences among procedures because slow movements may rely more on proprioceptive input


Bone & Joint 360
Vol. 3, Issue 3 | Pages 25 - 27
1 Jun 2014

The June 2014 Shoulder & Elbow Roundup. 360 . looks at: suprascapular nerve and rotator cuff pathology; anchors in Bankart repair: it’s not what you’ve got, but how you use it; not all shoulder PROMs are equal; reverse shoulder arthroplasty OK in trauma; not all in the mind: frozen shoulder personality debunked; open and arthroscopic repair equivalent in shoulder instability; natural history of olecranon fractures not so bleak?; and resurfacing of the shoulder: a Danish perspective


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 280 - 280
1 Mar 2004
Frankle M Mighell M Vasey M
Full Access

Aims: Outcomes for a RSP to treat either a previous operated shoulder (revision procedure) was compared to a primary RSP. Methods: 20 Primary RSP (6M, 14F) for an irreparable rotator cuff tear (IRCT) with glenohumeral arthritis/anterior superior arch deþciency and 31 revision RSP (10M, 21F) (previous rotator or cuff surgery, hemi or total shoulder arthroplasty) were evaluated at an average of 24 months postoperatively. Mean age at the time of RSP was 72.3 for primaries 67.2 for revisions. Assessment with pre- and postoperatively SF-36, SST, ASES scores, physical exam, satisfaction surveys, and radiographs was performed. Results: Primary RSP improvements/Revision RSP improvements were: 9.4 sf-36 PCS/6.3 sf-36 PCS, 1.8 SST/1.6 SST, 31.8 ASES/17.5 ASES (p< 0.05), 49.2 elevation/14.2 elevation (p< 0.05) and 57.8 external rotation/30 external rotation. 71.3% Excellent/good/. 56% Excellent/good (p< 0.05), 21.4% satisfactory/33.3% satisfactory, 7.1% unsatisfactory outcome/9.5% unsatisfactory outcome. Complications only occurred in the revisions including component disassociation, glenoid loosening, recurrent instability, and infection. Conclusion: Primary RSP provides predictable improvements in pain and function with minimal complications. Revision RSP has a higher complication rate and improvements in pain and function are less reliable. Conventional shoulder arthroplasty for patients with IRCT with glenohumeral arthritis/anterior superior arch deþciency has resulted in adequate pain relief but functional improvement has not been predictable. Thus, the initial operative selection for these patients must consider the effect of a failed reconstructive attempt on patient outcomes


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 85 - 85
1 Jul 2020
Willing R Soltanmohammadi P
Full Access

Statistical shape modeling (SSM) and statistical density modeling (SDM) are tools capable of describing the main modes of deviation in the shape and density distribution of the shoulder using a set of uncorrelated variables called principal components (PCs). We hypothesize that the first PC of the SDM, which scales overall density up/down, will be inversely correlated with age and will, on average, be greater for males than females. We also hypothesize that there is a correlation between some PCs of shape and density. SSM and SDM were developed for scapulae and humeri by segmenting surface meshes from computed tomographic images of 75 cadaveric shoulders. Bones were co-registered and defined by the same surface mesh. Volumetric tetrahedral meshes were defined for one of the specimens serving as base meshes for SDM. Base meshes were morphed to each individual bone's surface and superimposed upon the corresponding CT data to determine image intensity in Hounsfield units at each node. Principal component analysis was performed on the exterior shape and internal density distribution of bones. T-tests were performed to find any differences in PC scores between males and females, and Pearson correlation coefficients were calculated for age and PC scores. Finally, correlation coefficients between each of the PCs of the shape and density models were calculated. For the humerus, the first three PCs of the SDM were significantly correlated with age (ρ = 0.40, −0.46, and 0.36, all p ≤ 0.007). For the scapula, the first and ninth PCs showed such correlation (ρ = −0.31, and −0.32, all p ≤ 0.02). Statistically significant differences due to sex were found for the second to sixth SDM PCs of the humerus, with differences in average PC scores of 1, 1, −0.7, −0.8, and −0.6 standard deviations, respectively, for males relative to females. For the scapula, the second, fifth and seventh SDM PCs were significantly different between males and females, with average PC scores differing by 1.1, 0.7, and −0.6 standard deviations. Finally, for both bones, the first PC of SSM showed a weak but significant correlation with the second PC of the SDM (ρ = 0.47, p < 0.001 for the humerus, and ρ = 0.39, p < 0.001 for the scapula). The results of this study suggest that age has a significant influence on the first PC of the SDM, associated with scaling the density in the cortical boundary. Moreover, the negative correlation of age with the second PC of the humerus in SDM which mostly influences the thickness of the cortical boundary implies cortical thinning with age. The second PC of both bones differed significantly between males and females, implying that cortical thickness differs between sexes. Also, there was a significant correlation between the size of the bones and the thickness of the cortical boundary. These findings can help guide the designs of population-based prosthesis components


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 15 - 15
1 Apr 2019
Ramirez-Martinez I Smith S Joyce T
Full Access

INTRODUCTION. Shoulder joint prostheses have become the most commonly replaced after knee and hip artificial implants. Reverse shoulder arthroplasty (RSA) is the treatment option for patients with severe osteoarthritis, rotator cuff arthropathy or a massive rotator cuff tear with pseudoparalysis. Though successful, the long-term survival of such implants are limited by wear of the materials in contact [1, 2]. The aim of this study was to investigate RSA wear in vitro using a clinically relevant activities of daily living (ADLs). MATERIALS AND METHODS. Four new JRI Orthopaedics Reverse Shoulder 42 mm diameter VAIOS with cobalt-chromium (CoCr) glenospheres and ultra-high molecular weight polyethylene (UHMWPE) humeral components were tested. A five million cycles wear test was undertaken using the unique Newcastle Shoulder Wear Simulator with dilute bovine serum as a lubricant. “Mug to mouth” was performed as the ADL to the test prostheses in intervals of 100 cycles, following by 5 seconds of high load (450N) with no motion simulating an ADL such as “lifting an object”. This combined load cycle was then repeated. A fifth reverse shoulder prosthesis was subject to dynamic loading only in a soak control station. Wear was assessed gravimetrically and roughness (Sa) of the articulating surfaces was measured with a non-contacting profilometer. RESULTS AND DISCUSSION. The mean wear rate and standard deviation of the UHMWPE components was 11.4±3.7 mm. 3. /million cycles, while the CoCr components showed minimal wear over the test duration of 0.01± 0.02 mm. 3. /million cycles (Fig.1). Wear rates are comparable with Kohut et al. (14.1 mm. 3. /million cycles) [3] and Smith et al. (14.3±1.6 mm. 3. /million cycles) [4]. The CoCr glenospheres roughness was unchanged, from 32±8 nm Sa to 28±8 nm Sa over the 5 million cycles of the test (p=0.017), while the UHMWPE humeral components became smoother, from 692±123 nm Sa to 42±29 nm Sa (Fig.2), showing a statically significant change (p<0.001). CONCLUSION. The present study is the first wear test of artificial shoulder joints using a Motion-Load-Motion configuration as a clinically relevant physiological pattern of motion and load. Results are comparable with those found in the literature for in vitro testing of reverse shoulder replacements. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 79 - 79
1 Jan 2003
SCHAFER M FARKASHÁZI M
Full Access

A 18-year-old woman patient suffering from JCA was operated on non-dominant left shoulder joint destruction. The dysplasia of the affected side was clearly recognisable on the X-ray befor the operation as compared to the other side. The smallest of the prothesis typs (De Puy Global, Biomet Modular) couldn’t be implanted. So we have used an other method. We have achived good results for years by using Tuto-plast‚ Dura mater (Tutogen Medical GmbH) in operating interposition elbow arthtroplasty of RA patients. This was the basic idea in this case to apply shouldes joint interposition arthroplasty. There have been previous publications on other interposition tecniques. Operations technique:. Traditionally we approached the shoulder in deltopectoral sulcus. After the subscapular muscle tenotomy subtotal synovectomy happened, later pannus and osteophyts were removed from the humeral head. Then the surface of the head was refreshened, then arronund the anatomic neck titanium screws ( ORFI-II‚ anchor, Technomed) were placed and Tutoplast placed on the head was anchored to them. There are no shouldes pains 4 years after the operations, no radiologcal progression can be experienced. The range of motion is under the mesured value of the RA group of patient having shoulder prothesis. Despice of this fact the patient is able to look after herself and do the daily routine. The patient is fully satisfied with the operation. Conclusion:. Althaugh important conclusion can’t be drawn from one case but sometimes it gives a good alternativ solution in the area of prothetics in shoulder dysplasy of different origins


Bone & Joint 360
Vol. 10, Issue 6 | Pages 29 - 32
1 Dec 2021


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 98 - 98
1 Jul 2020
Khan M Alolabi B Horner N Ayeni OR Bedi A Bhandari M
Full Access

Shoulder impingement is one of the most common non-traumatic upper limb causes of disability in adults. Often resulting in pain and disability, management remains highly debated. This meta-analysis of randomized trials aims to evaluate the efficacy of surgical intervention in the setting of shoulder impingement in comparison to non-operative or sham treatments. Two reviewers independently screened MEDLINE, EMBASE, PUBMED and Cochrane databases for randomized control trials published from 1946 through to May 19th, 2018. A risk of bias assessment was conducted for all included studies and outcomes were pooled using a random effects model. The primary outcome was improvement in pain up to two years. Secondary outcomes included functional outcome scores reported at the short term (/=2 years). Heterogeneity was assessed using the I2statistic. Functional outcome scores were presented along with minimal clinically important differences to provide clinical context to findings. Twelve RCT's (n=1062 patients) were included in this review. Eligible patients were a mean age of 48 (SD +/− 4) years with 45% being male gender. The pooled treatment effect of surgical intervention for shoulder impingement did not demonstrate any benefit to surgery with respect to pain relief (mean difference [MD] −0.07, 95% CI −0.40 to 0.26) or short-term functional outcomes (standardized mean difference [SMD] −0.09, 95% confidence interval [CI] −0.27 to 0.08). Surgical intervention did result in a small statistically significant but clinically unimportant improvement in long term functional outcomes (SMD 0.23, 95% CI 0.06 to 0.41). Evidence suggests surgical intervention has little, if any, benefit for impingement pathology in the middle-aged patient


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 150 - 150
1 May 2016
Lerf R Reimelt I Dallmann F Delfosse D
Full Access

Background. When reversing the hard-soft articulation in inverse shoulder replacement, i.e. hard inlay and soft glenosphere (cf. Figure 1), the tribological behaviour of such a pairing has to be tested thoroughly. Therefore, two hard materials for the inlay, CoCr alloy and alumina toughened zirconia ceramic (ceramys®) articulating on two soft materials, conventional UHMWPE and vitamin E stabilised, highly cross-linked PE (vitamys®) were tested in a joint simulator. Methods. The simulator tests were performed at Endolab GmbH, Rosenheim, Germany, analogue to standardised gravimetric wear tests for hip prosthesis (ISO 14242-1) with load and motion curves adapted to the shoulder. The test parameters differing from the standard were the maximum force (1.0 kN) and the range of motion. A servo-hydraulic six station joint simulator (EndoLab) was used to run the tests up to 5*106 cycles with diluted calf serum at 37° C as lubricant. Visual inspection and mass measurements were done at 0.1, 0.5, 1, 2, 3, 4 and 5 million cycles using a high precision scale and a stereo microscope, respectivly. Results. The wear rates measured in the simulator are summarised in the table below and illustrated in Figure 2. The simulator wear rate of the standard articulation CoCr – UHMWPE is similar to that found in the corresponding pairing for hip endoprosthesis, although the articulation diameter of the glenospheres tested is larger (42 mm compared to 28 – 32 mm in hip joints). Replacing UHMWPE by the cross-linked vitamys®, the wear rate is reduced to about 1/3 for both hard counterparts, CoCr and ceramys®, respectively. Replacing the CoCr inlay by a part made from ceramys® lowers wear by about 37 % in articulation against UHMWPE. This difference is significant (p = 0.002, significance level 5 %). And comparing CoCr and ceramys® against vitamys®, yields a reduction of about 44 %. Which is significant again (p = 0.015, significance level 5 %). The lowest wear rate, with a reduction of about 80 % compared to the standard CoCr – UHMWPE, exhibits the pairing of both advanced materials, ceramys® – vitamys®. Conclusions. Long-term clinical follow-up will confirm if this in-vitro wear reduction leads to longer in-vivo survival of reverse total shoulder arthroplasty. Such a study is under ethic approval, currently. However, the ceramys® inlay offers the benefits of a nickel free inverse shoulder replacement with less x-ray opacity, compared to CoCr. To view tables/figures, please contact authors directly


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 85 - 85
1 Mar 2021
Hussain A Poyser E Mehta H
Full Access

Abstract. Introduction. Local anaesthetic injections are regularly used for perioperative pain relief for shoulder arthroscopies. In our practice all shoulder arthroscopies were performed under general aneasthesia supplemented by perioperative subacromial local anaesthetic injections or landmark guided axillary nerve together with suprascapular nerve injections. We compared pain relief achieved with these two methods. We hypothesized that the selective nerve blocks would provide better post operative pain relief as described in literature. Methods. We conducted a retrospective cohort study on two patient groups with 17 patients each. Group one patients received 20mls 50:50 mixture of 1% lignocaine and 0.5% chirocaine injections before and after start of procedure and group two patients received 20 mls of chirocaine around the axillary and suprascapular nerves. VAS scores were collected at 1 and 4 hours and analgesia taken during the first 24 hours was recorded. Results. No significant difference in pain scores was noted but analgesia requirements in the nerve block group were higher. Conclusion. Landmark guided nerve blocks did not show any advantage over subacromial local anaesthetic in our study. This is in contrast to published literature and we believe subacromial injections are more reliable and reproducible. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 709 - 712
1 May 2012
Di Gennaro GL Fosco M Spina M Donzelli O

The outcome of 56 children (61 shoulders) treated surgically at the Rizzoli Institute between April 1975 and June 2010 for congenital elevation of the scapula is reported. There were 31 girls and 25 boys with a mean age at surgery of 6.4 years (2 to 15). The deformity involved the right shoulder in 20 cases, the left in 31 and was bilateral in five. The degree of the deformity was graded clinically and radiologically according to the classifications of Cavendish and Rigault, respectively. All patients underwent a modified Green procedure combined, in selected cases, with resection of the superomedial portion of the scapula and excision of any omovertebral connection. After a mean follow-up of 10.9 years (1 to 29.3), there was cosmetic improvement by at least one Cavendish grade in 54 shoulders (88.5%). The mean abduction of the shoulder improved from 92° (50° to 155°) to 112° (90° to 170°) and the mean flexion improved from 121° (80° to 160°) to 155° (120° to 175°). The unsatisfactory cosmetic result in seven shoulders was due to coexistent scoliosis in two cases and insufficient reduction of the scapular elevation in the other five. An incomplete upper brachial plexus palsy occurred post-operatively in three patients but resolved within seven months. We suggest that a modified Green procedure combined with resection of the superomedial portion of the scapula provides good cosmetic and functional results in patients with Sprengel’s shoulder


Bone & Joint 360
Vol. 4, Issue 4 | Pages 23 - 24
1 Aug 2015

The August 2015 Shoulder & Elbow Roundup. 360 . looks at: Clavicular fractures are being fixed – but how?; Propionibacterium acnes: a pain in the shoulder?; Bacteria, armpits and arthroplasty; Living longer, but unhappy: the woes of shoulder arthroplasty in the under 50s; Recurrent dislocations in the adolescent population; Splinting for elbow stiffness; Revision Bankart repair


Bone & Joint 360
Vol. 1, Issue 6 | Pages 19 - 21
1 Dec 2012

The December 2012 Shoulder & Elbow Roundup. 360. looks at: whether allograft is biomechanically superior in large Hill-Sachs defects; glenoid bone loss in shoulder dislocators; repairing irreparable cuff tears; acromioclavicular joint injuries; whether more radiographs equals more surgery; whether reverse TSR is cheaper than hemiarthroplasty; autologous chondrocyte implantation in the shoulder; and fracture of the clavicle


Bone & Joint 360
Vol. 2, Issue 1 | Pages 25 - 27
1 Feb 2013

The February 2013 Shoulder & Elbow Roundup. 360 . looks at: whether we should replace fractured shoulders; the limited evidence for shoulder fractures; cuffs and early physio; matrix proteins and cuff tears; long-term SLAP tear outcomes; suture anchors; recurrent Bankart repairs; and acromial morphology and calcific tendonitis


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 485 - 492
1 Apr 2018
Gauci MO Bonnevialle N Moineau G Baba M Walch G Boileau P

Aims. Controversy about the use of an anatomical total shoulder arthroplasty (aTSA) in young arthritic patients relates to which is the ideal form of fixation for the glenoid component: cemented or cementless. This study aimed to evaluate implant survival of aTSA when used in patients aged < 60 years with primary glenohumeral osteoarthritis (OA), and to compare the survival of cemented all-polyethylene and cementless metal-backed glenoid components. Materials and Methods. A total of 69 consecutive aTSAs were performed in 67 patients aged < 60 years with primary glenohumeral OA. Their mean age at the time of surgery was 54 years (35 to 60). Of these aTSAs, 46 were undertaken using a cemented polyethylene component and 23 were undertaken using a cementless metal-backed component. The age, gender, preoperative function, mobility, premorbid glenoid erosion, and length of follow-up were comparable in the two groups. The patients were reviewed clinically and radiographically at a mean of 10.3 years (5 to 12, . sd. 26) postoperatively. Kaplan–Meier survivorship analysis was performed with revision as the endpoint. Results. A total of 26 shoulders (38%) underwent revision surgery: ten (22%) in the polyethylene group and 16 (70%) in the metal-backed group (p < 0.0001). At 12 years’ follow-up, the rate of implant survival was 74% (. sd.  0.09) for polyethylene components and 24% (. sd.  0.10) for metal-backed components (p < 0.0002). Glenoid loosening or failure was the indication for revision in the polyethylene group, whereas polyethylene wear with metal-on-metal contact, instability, and insufficiency of the rotator cuff were the indications for revision in the metal-backed group. Preoperative posterior subluxation of the humeral head with a biconcave/retroverted glenoid (Walch B2) had an adverse effect on the survival of a metal-backed component. Conclusion. The survival of a cemented polyethylene glenoid component is three times higher than that of a cementless metal-backed glenoid component ten years after aTSA in patients aged < 60 years with primary glenohumeral OA. Patients with a biconcave (B2) glenoid have the highest risk of failure. Cite this article: Bone Joint J 2018;100-B:485–92


Bone & Joint 360
Vol. 1, Issue 2 | Pages 21 - 23
1 Apr 2012

The April 2012 Shoulder & Elbow Roundup. 360 . looks at katakori in Japan, frozen shoulder, if shoulder impingement actually exists, shoulder arthroscopy and suprascapular nerve blocks, why shoulder replacements fail, the infected elbow replacement, the four-part fracture, the acromion index, and arm transplantation


Bone & Joint 360
Vol. 10, Issue 5 | Pages 29 - 32
1 Oct 2021