Advertisement for orthosearch.org.uk
Results 1 - 100 of 129
Results per page:

Aims. This study investigated vancomycin-microbubbles (Vm-MBs) and meropenem (Mp)-MBs with ultrasound-targeted microbubble destruction (UTMD) to disrupt biofilms and improve bactericidal efficiency, providing a new and promising strategy for the treatment of device-related infections (DRIs). Methods. A film hydration method was used to prepare Vm-MBs and Mp-MBs and examine their characterization. Biofilms of methicillin-resistant Staphylococcus aureus (MRSA) and Escherichia coli were treated with different groups. Biofilm biomass differences were determined by staining. Thickness and bacterial viability were observed with confocal laser scanning microscope (CLSM). Colony counts were determined by plate-counting. Scanning electron microscopy (SEM) observed bacterial morphology. Results. The Vm-MBs and Mp-MBs met the experimental requirements. The biofilm biomass in the Vm, Vm-MBs, UTMD, and Vm-MBs + UTMD groups was significantly lower than in the control group. MRSA and E. coli biofilms were most notably damaged in the Vm-MBs + UTMD group and Mp-MBs + UTMD group, respectively, with mean 21.55% (SD 0.08) and 19.73% (SD 1.25) remaining in the biofilm biomass. Vm-MBs + UTMD significantly reduced biofilm thickness and bacterial viability (p = 0.005 and p < 0.0001, respectively). Mp-MBs + UTMD could significantly decrease biofilm thickness and bacterial viability (allp < 0.001). Plate-counting method showed that the numbers of MRSA and E. coli bacterial colonies were significantly lower in the Vm-MBs + UTMD group and the Mp, Mp-MBs, UTMD, Mp-MBs + UTMD groups compared to the control group (p = 0.031). SEM showed that the morphology and structure of MRSA and E. coli were significantly damaged in the Vm-MBs + UTMD and Mp-MBs + UTMD groups. Conclusion. Vm-MBs or Mp-MBs combined with UTMD can effectively disrupt biofilms and protectively release antibiotics under ultrasound mediation, significantly reducing bacterial viability and improving the bactericidal effect of antibiotics. Cite this article: Bone Joint Res 2024;13(9):441–451


Bone & Joint Research
Vol. 11, Issue 3 | Pages 143 - 151
1 Mar 2022
Goetz J Keyssner V Hanses F Greimel F Leiß F Schwarz T Springorum H Grifka J Schaumburger J

Aims. Periprosthetic joint infections (PJIs) are rare, but represent a great burden for the patient. In addition, the incidence of methicillin-resistant Staphylococcus aureus (MRSA) is increasing. The aim of this rat experiment was therefore to compare the antibiotics commonly used in the treatment of PJIs caused by MRSA. Methods. For this purpose, sterilized steel implants were implanted into the femur of 77 rats. The metal devices were inoculated with suspensions of two different MRSA strains. The animals were divided into groups and treated with vancomycin, linezolid, cotrimoxazole, or rifampin as monotherapy, or with combination of antibiotics over a period of 14 days. After a two-day antibiotic-free interval, the implant was explanted, and bone, muscle, and periarticular tissue were microbiologically analyzed. Results. Vancomycin and linezolid were able to significantly (p < 0.05) reduce the MRSA bacterial count at implants. No significant effect was found at the bone. Rifampin was the only monotherapy that significantly reduced the bacterial count on implant and bone. The combination with vancomycin or linezolid showed significant efficacy. Treatment with cotrimoxazole alone did not achieve a significant bacterial count reduction. The combination of linezolid plus rifampin was significantly more effective on implant and bone than the control group in both trials. Conclusion. Although rifampicin is effective as a monotherapy, it should not be used because of the high rate of resistance development. Our animal experiments showed the great importance of combination antibiotic therapies. In the future, investigations with higher case numbers, varied bacterial concentrations, and changes in individual drug dosages will be necessary to be able to draw an exact comparison, possibly within a clinical trial. Cite this article: Bone Joint Res 2022;11(3):143–151


Aims. Treatment outcomes for methicillin-resistant Staphylococcus aureus (MRSA) periprosthetic joint infection (PJI) using systemic vancomycin and antibacterial cement spacers during two-stage revision arthroplasty remain unsatisfactory. This study explored the efficacy and safety of intra-articular vancomycin injections for PJI control after debridement and cement spacer implantation in a rat model. Methods. Total knee arthroplasty (TKA), MRSA inoculation, debridement, and vancomycin-spacer implantation were performed successively in rats to mimic first-stage PJI during the two-stage revision arthroplasty procedure. Vancomycin was administered intraperitoneally or intra-articularly for two weeks to control the infection after debridement and spacer implantation. Results. Rats receiving intra-articular vancomycin showed the best outcomes among the four treatment groups, with negative bacterial cultures, increased weight gain, increased capacity for weightbearing activities, increased residual bone volume preservation, and reduced inflammatory reactions in the joint tissues, indicating MRSA eradication in the knee. The vancomycin-spacer and/or systemic vancomycin failed to eliminate the MRSA infections following a two-week antibiotic course. Serum vancomycin levels did not reach nephrotoxic levels in any group. Mild renal histopathological changes, without changes in serum creatinine levels, were observed in the intraperitoneal vancomycin group compared with the intra-articular vancomycin group, but no changes in hepatic structure or serum alanine aminotransferase or aspartate aminotransferase levels were observed. No local complications were observed, such as sinus tract or non-healing surgical incisions. Conclusion. Intra-articular vancomycin injection was effective and safe for PJI control following debridement and spacer implantation in a rat model during two-stage revision arthroplasties, with better outcomes than systemic vancomycin administration. Cite this article: Bone Joint Res 2022;11(6):371–385


Bone & Joint Research
Vol. 9, Issue 5 | Pages 211 - 218
1 May 2020
Hashimoto A Miyamoto H Kobatake T Nakashima T Shobuike T Ueno M Murakami T Noda I Sonohata M Mawatari M

Aims. Biofilm formation is intrinsic to prosthetic joint infection (PJI). In the current study, we evaluated the effects of silver-containing hydroxyapatite (Ag-HA) coating and vancomycin (VCM) on methicillin-resistant Staphylococcus aureus (MRSA) biofilm formation. Methods. Pure titanium discs (Ti discs), Ti discs coated with HA (HA discs), and 3% Ag-HA discs developed using a thermal spraying were inoculated with MRSA suspensions containing a mean in vitro 4.3 (SD 0.8) x 10. 6. or 43.0 (SD 8.4) x 10. 5. colony-forming units (CFUs). Immediately after MRSA inoculation, sterile phosphate-buffered saline or VCM (20 µg/ml) was added, and the discs were incubated for 24 hours at 37°C. Viable cell counting, 3D confocal laser scanning microscopy with Airyscan, and scanning electron microscopy were then performed. HA discs and Ag HA discs were implanted subcutaneously in vivo in the dorsum of rats, and MRSA suspensions containing a mean in vivo 7.2 (SD 0.4) x 10. 6.   or 72.0 (SD 4.2) x 10. 5.   CFUs were inoculated on the discs. VCM was injected subcutaneously daily every 12 hours followed by viable cell counting. Results. Biofilms that formed on HA discs were thicker and larger than those on Ti discs, whereas those on Ag-HA discs were thinner and smaller than those on Ti discs. Viable bacterial counts in vivo revealed that Ag-HA combined with VCM was the most effective treatment. Conclusion. Ag-HA with VCM has a potential synergistic effect in reducing MRSA biofilm formation and can thus be useful for preventing and treating PJI. Cite this article:Bone Joint Res. 2020;9(5):211–218


Aims. Methicillin-resistant Staphylococcus aureus (MRSA) can cause wound infections via a ‘Trojan Horse’ mechanism, in which neutrophils engulf intestinal MRSA and travel to the wound, releasing MRSA after apoptosis. The possible role of intestinal MRSA in prosthetic joint infection (PJI) is unknown. Methods. Rats underwent intestinal colonization with green fluorescent protein (GFP)-tagged MRSA by gavage and an intra-articular wire was then surgically implanted. After ten days, the presence of PJI was determined by bacterial cultures of the distal femur, joint capsule, and implant. We excluded several other possibilities for PJI development. Intraoperative contamination was excluded by culturing the specimen obtained from surgical site. Extracellular bacteraemia-associated PJI was excluded by comparing with the infection rate after intravenous injection of MRSA or MRSA-carrying neutrophils. To further support this theory, we tested the efficacy of prophylactic membrane-permeable and non-membrane-permeable antibiotics in this model. Results. After undergoing knee surgery eight or 72 hours after colonization, five out of 20 rats (25.0%) and two out of 20 rats (10.0%) developed PJI, respectively. Strikingly, 11 out of 20 rats (55.0%) developed PJI after intravenous injection of MRSA-carrying neutrophils that were isolated from rats with intestinal MRSA colonization. None of the rats receiving intravenous injections of MRSA developed PJI. These results suggest that intestinal MRSA carried by neutrophils could cause PJI in our rat model. Ten out of 20 (50.0%) rats treated with non-membrane-permeable gentamicin developed PJI, whereas only one out of 20 (5.0%) rats treated with membrane-permeable linezolid developed PJI. Conclusion. Neutrophils as carriers of intestinal MRSA may play an important role in PJI development. Cite this article:Bone Joint Res. 2020;9(4):152–161


Bone & Joint Research
Vol. 9, Issue 2 | Pages 49 - 59
1 Feb 2020
Yu K Song L Kang HP Kwon H Back J Lee FY

Aims. To characterize the intracellular penetration of osteoblasts and osteoclasts by methicillin-resistant Staphylococcus aureus (MRSA) and the antibiotic and detergent susceptibility of MRSA in bone. Methods. Time-lapse confocal microscopy was used to analyze the interaction of MRSA strain USA300 with primary murine osteoblasts and osteoclasts. The effects of early and delayed antibiotic treatments on intracellular and extracellular bacterial colony formation and cell death were quantified. We tested the effects of cefazolin, gentamicin, vancomycin, tetracycline, rifampicin, and ampicillin, as well as agents used in surgical preparation and irrigation. Results. MRSA infiltrated bone-resident cells within 15 to 30 minutes. Penetration was most effectively prevented with early (i.e. 30 minutes) antibiotic administration. The combined administration of rifampicin with other antibiotics potentiated their protective effects against MRSA-induced cytotoxicity and most significantly reduced extracellular bacterial bioburden. Gentamicin-containing compounds were most effective in reducing intracellular MRSA bioburden. Of the surgical preparation agents evaluated, betadine reduced in vitro MRSA growth to the greatest extent. Conclusion. The standard of care for open fractures involves debridement and antibiotics within the first six hours of injury but does not account for the window in which bacteria penetrate cells. Antibiotics must be administered as early as possible after injury or prior to incision to prevent intracellular infestation. Rifampicin can potentiate the capacity of antibiotic regimens to reduce MRSA-induced cytotoxicity. Cite this article:Bone Joint Res. 2020;9(2):49–59


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 807 - 811
1 Jun 2006
Roche SJ Fitzgerald D O’Rourke A McCabe JP

This prospective five-year study analyses the impact of methicillin-resistant Staphylococcus aureus (MRSA) on an Irish orthopaedic unit. We identified 318 cases of MRSA, representing 0.76% of all admissions (41 971). A total of 240 (76%) cases were colonised with MRSA, while 120 (37.7%) were infected. Patients were admitted from home (218; 68.6%), nursing homes (72; 22.6%) and other hospitals (28; 8.8%). A total of 115 cases (36.6%) were colonised or infected on admission. Many patients were both colonised and infected at some stage. The length of hospital stay was almost trebled because of the presence of MRSA infection. Encouragingly, overall infection rates have not risen significantly over the five years of the study despite increased prevalence of MRSA. However, the financial burden of MRSA is increasing, highlighting the need for progress in understanding how to control this resistant pathogen more effectively


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 170 - 177
4 Jan 2021
Craxford S Marson BA Oderuth E Nightingale J Agrawal Y Ollivere B

Aims. Infection after surgery increases treatment costs and is associated with increased mortality. Hip fracture patients have historically had high rates of methicillin-resistant Staphylococcus aureus (MRSA) colonization and surgical site infection (SSI). This paper reports the impact of routine MRSA screening and the “cleanyourhands” campaign on rates of MRSA SSI and patient outcome. Methods. A total of 13,503 patients who presented with a hip fracture over 17 years formed the study population. Multivariable logistic regression was performed to determine risk factors for MRSA and SSI. Autoregressive integrated moving average (ARIMA) modelling adjusted for temporal trends in rates of MRSA. Kaplan-Meier estimators were generated to assess for changes in mortality. Results. In all, 6,189 patients were identified before the introduction of screening and 7,314 in the post-screening cohort. MRSA infection fell from 69 cases to 15 in the post-screening cohort (p < 0.001). The ARIMA confirmed a significant reduction in MRSA SSI post-screening (p = 0.043) but no significant impact after hand hygiene alone (p = 0.121). Overall SSI fell (2.4% to 1.5%), however deep infection increased slightly (0.89% to 1.06%). ARIMA showed neither intervention affected overall SSI (“cleanyourhands” -0.172% (95% confidence interval (CI) -0.39% to 0.21); p = 0.122, screening -0.113% per year, (95% CI -0.34 to 0.12); p = 0.373). One-year mortality after deep SSI was unchanged after screening (50% vs 45%; p = 0.415). Only warfarinization (OR 3.616 (95% CI 1.366 to 9.569); p = 0.010) and screening (OR 0.189 (95% CI 0.086 to 0.414); p < 0.001) were significant covariables for developing MRSA SSI. Conclusion. While screening and decolonization may reduce MRSA-associated SSI, the benefit to patient outcome remains unclear. Overall deep SSI remains an unsolved problem that has seen little improvement over time. Preventing other hospital-associated infections should not be forgotten in the fight against MRSA. Cite this article: Bone Joint J 2021;103-B(1):170–177


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 13 - 17
1 Jun 2021
Park KJ Chapleau J Sullivan TC Clyburn TA Incavo SJ

Aims. Infection complicating primary total knee arthroplasty (TKA) is a common reason for revision surgery, hospital readmission, patient morbidity, and mortality. Increasing incidence of methicillin-resistant Staphylococcus aureus (MRSA) is a particular concern. The use of vancomycin as prophylactic agent alone or in combination with cephalosporin has not demonstrated lower periprosthetic joint infection (PJI) rates, partly due to timing and dosing of intravenous (IV) vancomycin administration, which have proven important factors in effectiveness. This is a retrospective review of a consecutive series of primary TKAs examining incidence of PJI, adverse reactions, and complications using IV versus intraosseous (IO) vancomycin at 30-day, 90-day, and one-year follow-up. Methods. A retrospective review of 1,060 patients who underwent TKA between May 2016 to July 2020 was performed. There were 572 patients in the IV group and 488 in the IO group, with minimal 30 days of follow-up. Patients were followed up at regularly scheduled intervals (two, six, and 12 weeks). No differences between groups for age, sex, BMI, or baseline comorbidities existed. The IV group received an IV dose of 15 mg/kg vancomycin given over an hour preceding skin incision. The IO group received a 500 mg dose of vancomycin mixed in 150 ml of normal saline, injected into proximal tibia after tourniquet inflation, before skin incision. All patients received an additional dose of first generation cephalosporin. Evaluation included preoperative and postoperative serum creatinine values, tourniquet time, and adverse reactions attributable to vancomycin. Results. Incidence of PJI with minimum 90-day follow-up was 1.4% (eight knees) in the IV group and 0.22% (one knee) in IO group (p = 0.047). This preliminary report demonstrated an reduction in the incidence of infection in TKA using IO vancomycin combined with a first-generation cephalosporin. While the study suffers from limitations of a retrospective, multi-surgeon investigation, early findings are encouraging. Conclusion. IO delivery of vancomycin after tourniquet inflation is a safe and effective alternative to IV administration, eliminating the logistical challenges of timely dosing. Cite this article: Bone Joint J 2021;103-B(6 Supple A):13–17


Bone & Joint Research
Vol. 6, Issue 3 | Pages 132 - 136
1 Mar 2017
Yuenyongviwat V Ingviya N Pathaburee P Tangtrakulwanich B

Objectives. Vancomycin and fosfomycin are antibiotics commonly used to treat methicillin-resistant Staphylococcus aureus (MRSA) infection. This study compares the in vitro inhibitory effects against MRSA of articulating cement spacers impregnated with either vancomycin or fosfomycin. Methods. Vancomycin-impregnated articulating cement spacers and fosfomycin-impregnated articulating cement spacers were immersed in sterile phosphate-buffered saline (PBS) solutions and then incubated. Samples were collected for bioactivity evaluation. The aliquots were tested for MRSA inhibition with the disc diffusion method, and the inhibition zone diameters were measured. The inhibition zone differences were evaluated using the Wilcoxon Rank Sum Test. Results. The vancomycin group had significantly larger inhibition zones than the fosfomycin group from day three through to completion of the fourth week of incubation (p < 0.001). The vancomycin group exhibited a MRSA inhibition zone up to four weeks but the fosfomycin group showed an inhibition zone for only three days and after that did not show the the potential to inhibit MRSA. Conclusion. This in vitro study found that the inhibitory effect of vancomycin-impregnated articulating cement spacers against MRSA outperformed fosfomycin-impregnated articulating cement spacers. Further comparing our results to other published reports suggests there might be a limitation of the disc diffusion bioassay to show a large inhibitory zone in a high concentration of a highly soluble antibiotic. Cite this article: V. Yuenyongviwat, N. Ingviya, P. Pathaburee, B. Tangtrakulwanich. Inhibitory effects of vancomycin and fosfomycin on methicillin-resistant Staphylococcus aureus from antibiotic-impregnated articulating cement spacers. Bone Joint Res 2017;6:132–136. DOI: 10.1302/2046-3758.63.2000639


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 548 - 551
1 Apr 2011
Murphy E Spencer SJ Young D Jones B Blyth MJG

The objective of this study was to determine the effectiveness of screening and successful treatment of methicillin-resistant Staphylococcus aureus (MRSA) colonisation in elective orthopaedic patients on the subsequent risk of developing a surgical site infection (SSI) with MRSA. We screened 5933 elective orthopaedic in-patients for MRSA at pre-operative assessment. Of these, 108 (1.8%) were colonised with MRSA and 90 subsequently underwent surgery. Despite effective eradication therapy, six of these (6.7%) had an SSI within one year of surgery. Among these infections, deep sepsis occurred in four cases (4.4%) and superficial infection in two (2.2%). The responsible organism in four of the six cases was MRSA. Further analysis showed that patients undergoing surgery for joint replacement of the lower limb were at significantly increased risk of an SSI if previously colonised with MRSA. We conclude that previously MRSA-colonised patients undergoing elective surgery are at an increased risk of an SSI compared with other elective patients, and that this risk is significant for those undergoing joint replacement of the lower limb. Furthermore, when an infection occurs, it is likely to be due to MRSA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 18 - 18
10 Feb 2023
Foster A Boot W Stenger V D'Este M Jaiprakash A Crawford R Schuetz M Eglin D Zeiter S Richards R Moriarty T
Full Access

Local antimicrobial therapy is an integral aspect of treating orthopaedic device related infection (ODRI), which is conventionally administered via polymethylmethacrylate (PMMA) bone cement. PMMA, however, is limited by a suboptimal antibiotic release profile and a lack of biodegradability. In this study, we compare the efficacy of PMMA versus an antibioticloaded hydrogel in a single- stage revision for chronic methicillin-resistant Staphylococcus aureus (MRSA) ODRI in. sheep. Antibiofilm activity of the antibiotic combination (gentamicin and vancomycin) was determined in vitro. Swiss alpine sheep underwent a single-stage revision of a tibial intramedullary nail with MRSA infection. Local gentamicin and vancomycin therapy was delivered via hydrogel or PMMA (n = 5 per group), in conjunction with systemic antibiotic therapy. In vivo observations included: local antibiotic tissue concentration, renal and liver function tests, and quantitative microbiology on tissues and hardware post-mortem. There was a nonsignificant reduction in biofilm with an increasing antibiotic concentration in vitro (p = 0.12), confirming the antibiotic tolerance of the MRSA biofilm. In the in vivo study, four out of five sheep from each treatment group were culture negative. Antibiotic delivery via hydrogel resulted in 10–100 times greater local concentrations for the first 2–3 days compared with PMMA and were comparable thereafter. Systemic concentrations of gentamicin were minimal or undetectable in both groups, while renal and liver function tests were within normal limits. This study shows that a single-stage revision with hydrogel or PMMA is equally effective, although the hydrogel offers certain practical benefits over PMMA, which make it an attractive proposition for clinical use


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 812 - 817
1 Jun 2006
Nixon M Jackson B Varghese P Jenkins D Taylor G

We examined the rates of infection and colonisation by methicillin-resistant Staphylococcus aureus (MRSA) between January 2003 and May 2004 in order to assess the impact of the introduction of an MRSA policy in October 2003, which required all admissions to be screened. Emergency admissions were treated prophylactically and elective beds ring-fenced. A total of 5594 admissions were cross-referenced with 22 810 microbiology results. The morbidity, mortality and cost of managing MRSA-carrying patients, with a proximal fracture of the femur were compared, in relation to age, gender, American Society of Anaesthesiologists grade and residential status, with a group of matched controls who were MRSA-negative. In 2004, we screened 1795 of 1796 elective admissions and MRSA was found in 23 (1.3%). We also screened 1122 of 1447 trauma admissions and 43 (3.8%) were carrying MRSA. All ten ward transfers were screened and four (40%) were carriers (all p < 0.001). The incidence of MRSA in trauma patients increased by 2.6% per week of inpatient stay (r = 0.97, p < 0.001). MRSA developed in 2.9% of trauma and 0.2% of elective patients during that admission (p < 0.001). The implementation of the MRSA policy reduced the incidence of MRSA infection by 56% in trauma patients (1.57% in 2003 (17 of 1084) to 0.69% in 2004 (10 of 1447), p = 0.035). Infection with MRSA in elective patients was reduced by 70% (0.56% in 2003 (7 of 1257) to 0.17% in 2004 (3 of 1806), p = 0.06). The cost of preventing one MRSA infection was £3200. Although colonisation by MRSA did not affect the mortality rate, infection by MRSA more than doubled it. Patients with proximal fractures of the femur infected with MRSA remained in hospital for 50 extra days, had 19 more days of vancomycin treatment and 26 more days of vacuum-assisted closure therapy than the matched controls. These additional costs equated to £13 972 per patient. From this experience we have been able to describe the epidemiology of MRSA, assess the impact of infection-control measures on MRSA infection rates and determine the morbidity, mortality and economic cost of MRSA carriage on trauma and elective orthopaedic wards


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 15 - 15
2 Jan 2024
Costa B Alves P Fonseca D Campos F Monteiro AC Pereira R Costa F Gomes P Martínez-de-Tejada G Monteiro C Martins M
Full Access

Orthopedic Device-Related Infections (ODRIs) are a major medical challenge, particularly due to the involvement of biofilm-encased and multidrug-resistant bacteria. Current treatments, based on antibiotic administration, have proven to be ineffective. Consequently, there is a need for antibiotic-free alternatives. Antimicrobial peptides (AMPs) are a promising solution due to their broad-spectrum of activity, high efficacy at very low concentrations, and low propensity to induce resistance. We aim to develop a new AMP-based chitosan nanogel to be injected during orthopedic device implantation to prevent ODRIs. Chitosan was functionalized with norbornenes (NorChit) through the reaction with carbic anhydride and then, a cysteine-modified AMP, Dhvar5, a peptide with potent antibacterial activity, even against methicillin-resistant Staphylococcus aureus (MRSA), was covalently conjugated to NorChit (NorChit- Dhvar5), through a thiol-norbornene photoclick chemistry (UV= 365 nm). For NorChit-Dhvar5 nanogels production, the NorChit-Dhvar5 solution (0.15% w/v) and Milli-Q water were injected separately into microfluidic system. The nanogels were characterized regarding size, concentration, and shape, using Transmission Electron Microscopy (TEM), Nanoparticle Tracking Analysis (NTA) and Dynamic light scattering (DLS). The nanogels antibacterial properties were assessed in Phosphate Buffer (PBS) for 6 h, against four relevant microorganisms (Pseudomonas aeruginosa, S. aureus and MRSA, and in Muller- Hinton Broth (MHB), 50% (v/v) in PBS, supplemented with human plasma (1% (v/v)), for 6 and 24 h against MRSA. The obtained NorChit-Dhvar5 nanogels, presented a round-shaped and ∼100 nm. NorChit- Dhvar5 nanogels in a concentration of 10. 10. nanogels/mL in PBS were capable of reducing the initial inoculum of P. aeruginosa by 99%, S. aureus by 99%, and MRSA by 90%. These results were corroborated by a 99% MRSA reduction, after 24 h in medium. Furthermore, NorChit-Dhvar5 nanogels do not demonstrate signs of cytotoxicity against MC3T3-E1 cells (a pre-osteoblast cell line) after 14 days, having high potential to prevent antibiotic-resistant infection in the context of ODRIs


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 27 - 27
24 Nov 2023
Chen B Chittò M Benavente LP Post V Moreno MG Zeiter S Trampuz A Wagemans J Lavigne R Onsea J Metsemakers W Moriarty F
Full Access

Aim. Bacteriophages are remerging as alternative and adjunctive therapy for fracture-related infection (FRI). However, current administration protocols involve prolonged retention of a percutaneous draining tube with potential risk of developing superinfection. In this study, we applied a cocktail of in vitro evolved biofilm-targeting phages for Methicillin-resistant Staphylococcus aureus (MRSA) in a hydrogel platform co-delivering vancomycin. In vitro synergy and antibiofilm activity was assessed and a subsequent in vivo study was performed in a mouse FRI model with MRSA. Method. Two evolved bacteriophages (MRSA-R14 and COL-R23) with improved antibiofilm activity against a clinical isolate (MRSA3) were tested in combination with vancomycin and a carboxymethylcellulose (CMC) hydrogel in vitro and in vivo. MRSA3 bacterial biofilms were formed on sterile 4 mm sintered porous glass beads at 37 °C for 24 h. Biofilms were exposed to i-phage cocktail (10. 7. PFU/ml), ii-vancomycin at concentrations of 0.5, 1, 10 and 100 times the MIC, or iii-combination of phage cocktail and vancomycin. Recovered biofilm cells, were quantified by colony counting. The stability and release profiles of phage cocktail and vancomycin in co-delivery hydrogel were assessed in vitro for 8 days and 72 hrs, respectively, and subsequently tested in the treatment of 5-day-old MRSA3 infection of a femoral plate osteotomy in mice. Results. In vitro: The cocktail of evolved phages (10. 7. PFU/ml, 1:1) combined with 0.5 MIC vancomycin achieved 99.72% reduction in MRSA3 biofilm in vitro compared to the growth control. This combination was stable in the co-delivery hydrogel over 8 days. The release profile showed that 57% of phages and 80% of vancomycin were released after 72hrs, which was identical to the performance for gels loaded with phage or antibiotic alone. In the in vivo study, the bacterial load from animals that received co-delivery hydrogel and systemic vancomycin was significantly reduced compared to controls, animals that received systemic vancomycin and animals that received co-delivery hydrogel alone (p<0.05). Conclusions. Our study demonstrates the potential of using evolved phages in combination with vancomycin and hydrogel delivery systems for the treatment of MRSA-related infections. Further research in this area may lead to the development of specific therapies for biofilm-related infection


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 26 - 26
24 Nov 2023
Morovic P Benavente LP Karbysheva S Perka C Trampuz A
Full Access

Aim. Antibiotics have limited activity in the treatment of multidrug-resistant or chronic biofilm-associated infections, in particular when implants cannot be removed. Lytic bacteriophages can rapidly and selectively kill bacteria, and can be combined with antibiotics. However, clinical experience in patients with surgical infections is limited. We investigated the outcome and safety of local application of bacteriophages in addition to antimicrobial therapy. Method. 8 patients (2 female and 6 male) with complex orthopedic and cardiovascular infections were included, in whom standard treatment was not feasible or impossible. The treatment was performed in agreement with the Article 37 of the Declaration of Helsinki. Commercial or individually prepared bacteriophages were provided by ELIAVA Institute in Tbilisi, Georgia. Bacteriophages were applied during surgery and continued through drains placed during surgery three times per day for the following 5–14 days. Follow-up ranged from 1 to 28 months. Results. Median age was 57 years, range 33–75 years. Two patients were diagnosed with a persistent knee arthrodesis infection, one chronic periprosthetic joint infection (PJI), one cardiovascular implantable electronic device (CIED) infection and four patients with left ventricular assist device (LVAD) infection. The isolated pathogens were multi-drug-resistant Pseudomonas aeruginosa (n=3), methicillin-sensitive Staphylococcus aureus (n=4), methicillin-resistant Staphylococcus aureus (MRSA) (n=1) and methicillin-resistant Staphylococcus epidermidis (MRSE) (n=1). 4 infections were polymicrobial. 5 patients underwent surgical debridement with retention of the implant, 1 patient with PJI underwent the exchange of the prosthesis and one patient with LVAD infection was treated conservatively. All patients received intravenous and oral antibiotic therapy and local application of bacteriophages. At follow-up of 12 month, 5 patients were without signs or symptoms of infection, whereas in one patient with LVAD infection, a relapse was observed with emergence of phage-resistant Pseudomonas aeruginosa. In this patient, no surgical revision was performed. Conclusions. Bacteriophage therapy may represent a valid additional approach, when standard antimicrobial and surgical treatment is not possible or feasible, including in difficult-to-treat infections. In our case series, 5 of 6 patients were infection free after 1 year. Further studies need to address the optimal bacteriophage administration route, concentration, duration of treatment and combination with antimicrobials


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 225 - 228
1 Feb 2009
Shukla S Nixon M Acharya M Korim MT Pandey R

We examined the incidence of infection with methicillin-resistant Staphylococcus aureus (MRSA) in patients admitted to the Leicester Royal Infirmary Trauma Unit between January 2004 and June 2006. The influence of MRSA status at the time of their admission was examined, together with age, gender and diagnosis, using multi-variant analysis. Of 2473 patients, 79 (3.2%) were MRSA carriers at the time of admission and 2394 (96.8%) were MRSA-negative. Those carrying MRSA at the time of admission were more likely to develop surgical site infection with MRSA (7 of 79 patients, 8.8%) than non-MRSA carriers (54 of 2394 patients, 2.2%, p < 0.001). Further analysis showed that hip fracture and increasing age were also risk factors with a linear increase in relative risk of 1.8% per year. MRSA carriage at admission, age and the pathology are all associated with an increased rate of developing MRSA wound infection. Identification of such risk factors at admission helps to target health-care resources, such the use of glycopeptide antibiotics at induction and the ‘building-in’ of increased vigilance for wound infection pre-operatively


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 642 - 645
1 May 2007
Kaminski A Kammler J Wick M Muhr G Kutscha-Lissberg F

Between October 2001 and February 2002, 324 healthcare workers were screened for methicillin-resistant Staphylococcus aureus (MRSA) by nose and throat swabs. A positive finding led to activation of a standardised control programme for the affected person who was immediately excluded from work. Family members of those who were MRSA-positive were offered screening free of charge. An eradication programme was carried out in the permanent carriers. MRSA was found in 17 (5.3%) healthcare workers, 11 of whom proved to be permanent carriers, and six temporarily colonised. Three children of a positive healthcare worker showed nasopharyngeal MRSA, the acquisition of which occurred within the hospital. The standardised eradication programme for carriers was successful in most cases but failed in two individuals, whereupon systemic antibiotics were used successfully. The decolonised carriers, observed for more than one year, remained MRSA negative. Isolation precautions in hospitals do not always prevent hospital staff and their families from acquiring MRSA. The identification of affected employees is difficult because in most cases only asymptomatic colonisation occurs. Screening and eradication can be complicated and costly, and for the affected employees the occupational consequences can be far-reaching as they have no guaranteed legal protection


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 52 - 52
1 Oct 2022
Müller N Trampuz A Gonzalez-Moreno M
Full Access

Aim. The rise of multidrug-resistant bacteria and the decreasing efficacy of antibiotic therapy in successfully treating biofilm-associated infections are prompting the exploration of alternative treatment options. This study investigates the efficacy of different bioactive glass (BAG) formulations - alone or combined with vancomycin - to eradicate biofilm. Further, we study the influence of BAG on pH and osmotic pressure as important factors limiting bacterial growth. Method. Different BAG-S53P4 formulations were used for this study, including (a) BAG-powder (<45 μm), (b) BAG-granules (500–800 μm), (c) a cone-shaped BAG-scaffold and (d) two kinds of BAG-putty containing granules, with no powder (putty-A) or with additional powder (putty-B), and a synthetic binder. Inert glass beads were included as control. All formulations were tested in a concentration of 1750 g/ml in Müller-Hinton-Broth. Targeted bacteria included methicillin-resistant Staphylococcus aureus (MRSA) and epidermidis (MRSE). Vancomycin was tested at the minimum-inhibitory-concentration for each strain (1 µg/ml for MRSA; 2 μg/ml for MRSE). To investigate the antibiofilm effect of BAG alone or combined with vancomycin, 3 hour-old MRSA or MRSE biofilms were formed on porous glass beads and exposed to BAG ± vancomycin for 24h, 72h and 168h. After co-incubation, biofilm-beads were deep-washed in phosphate-buffered saline and placed in glass vials containing fresh medium. Recovering biofilm bacteria were detected by measuring growth-related heat production at 37°C for 24h by isothermal microcalorimetry. Changes in pH and osmotic pressure over time were assessed after co-incubation of each BAG formulation in Müller-Hinton-Broth for 0h, 24h, 72h and 168h. Results. All BAG formulations showed antibiofilm activity against MRSA and MRSE in a time-dependent manner, where longer incubation times revealed higher antibiofilm activity. BAG-powder and BAG-putty-B were the most effective formulations suppressing biofilm, followed by BAG-granules, BAG-scaffold and finally BAG-putty-A. The addition of vancomycin had no substantial impact on biofilm suppression. An increase in pH and osmotic pressure over time could be observed for all BAG formulations. BAG-powder reached the highest pH value of 12.5, whereas BAG-putty-A resulted in the lowest pH of 9. Both BAG-putty formulations displayed the greatest increase on osmotic pressure. Conclusions. BAG-S53P4 has demonstrated efficient biofilm suppression against MRSA and MRSE, especially in powder-containing formulations. Our data indicates no additional antibiofilm improvement with addition of vancomycin. Moreover, high pH appears to have a larger antimicrobial impact than high osmolarity. Acknowledgements. This work was supported by PRO-IMPLANT Foundation (Berlin, Germany). The tested materials were provided by Bonalive Biomaterials Ltd (Turku, Finland)


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 54 - 54
1 Apr 2018
Francis K
Full Access

Each year more than 70 billion standard units of antibiotic are prescribed to treat bacterial infections worldwide. In addition, at least 63,000 tons of antibiotics are consumed by livestock for growth promotion and disease prevention. The result of this overuse of antibiotics is a spiraling increase in resistance. In the United States and Europe, antibiotic resistant bacteria are responsible for more than 4 million infections and approximately 50,000 deaths annually. In addition, bacteria such as methicillin-resistant Staphylococcus aureus (MRSA) have increased in prevalence in hospitals over the last three decades. Such bacteria are particularly problematic in postoperative infections, exacerbating treatment through the development of biofilms, especially on medical implants which are virtually impossible to treat without removal and replacement of the device. This presentation will show how non-invasive preclinical imaging (optical, PET and CT) is being used to better understand the establishment and development of bacterial infections in vivo, and how best to treat them. In particular, data will be shown as to how preclinical imaging can be used to monitor bacterial infections on orthopaedic implants, and how this technology might be translated into the clinic


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 91 - 91
1 Dec 2019
Scheper H Verhagen J de Visser A van der Wal R Wubbolts J Visser LG Boer MGJD Nibbering PH
Full Access

Aims. Prosthetic joint infection (PJI) remains the most severe complication of arthroplasty. Failure of intensive, long-term antibiotic treatment for PJI often requires removal of the implant. Antibiotic failure is thought to be caused by biofilm and persister formation. Novel anti-biofilm and anti-persister strategies are urgently needed. Here, we investigated the effects of several antimicrobial peptides on the bacteria within antibiotic-treated biofilms in an in vitro mature biofilm model on abiotic surfaces. Methods. On polystyrene, a mature (7 day-old) methicillin-resistant Staphylococcus aureus (MRSA) biofilm was developed. Thereafter, bacteria in the biofilm were exposed to rifampicin and ciprofloxacin (both 10× >MIC) for three days. Surviving bacteria in the antibiotic-treated biofilm, presumed to include persisters, were exposed to increasing doses of the antimicrobial peptides SAAP-148, acyldepsipeptide 4 (ADEP4), LL-37 and pexiganan. SAAP-148 was further tested on antibiotic-treated mature biofilms on titanium/aluminium/niobium (TAN) discs and prosthetic joint liners. Results. Daily exposure of the mature biofilm for seven days with antibiotics resulted in a 4-log reduction of MRSA without elimination of the bacteria. The surviving bacteria within the biofilm were eliminated upon subsequent exposure to SAAP-148 and pexiganan but not with LL-37 ad ADEP4. Antibiotic treatment of mature biofilms on TAN discs followed by SAAP-148 also resulted in eradication of bacteria within the biofilm. SAAP-148 also fully eliminated bacteria within antibiotic-treated mature MRSA biofilms on an ex vivo liner of a prosthetic joint. Conclusions. A novel mature biofilm model has been developed in which the efficacy of antimicrobial peptides against bacteria, including persisters, residing within a biofilm was investigated. SAAP-148 and pexiganan were highly effective against the bacteria residing in antibiotic-exposed mature MRSA biofilms. This in vitro model system will be used to analyze the effects of novel antibiotic strategies and other anti-PJI agents


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 88 - 88
1 Dec 2019
Luca MD Materazzi A Klatt A Bottai D Tavanti A Trampuz A
Full Access

Aim. To investigate the ability of the bacteriophage Sb-1 to treat and prevent implant-associated infections due to methicillin-resistant Staphylococcus aureus (MRSA) in Galleria mellonella larvae implanted with a K-wire. Method. The stability of Sb-1 in G. mellonella larvae was investigated by injecting a phage titer of 10. 8. PFU and evaluating the presence of Sb-1 in hemolymph at different time points. For infection experiments, sterile stainless-steel K-wires (4 mm, 0.6 mm Ø) were implanted into larvae. Two days after implant, larvae were infected with MRSA ATCC 43300 (1×10. 5. CFU) and incubated at 37°C for further 2 days. Implanted-infected larvae were thus treated for 2 days (3×/day) with 10µL of: i) PBS; ii) Sb-1 (10. 7. PFU); iii) Daptomycin (4mg/kg), iv) PBS (24h)/Daptomycin(24h); v) Sb-1(24h)/Daptomycin(24h). To evaluate the prophylactic efficacy of Sb-1, an experiment based on phages or vancomycin (10mg/kg) administration, followed by MRSA infection of implanted larvae was performed. Both two days post-infection and post-treatment, K-wires were explanted, and the material was sonicated and plated for MRSA colony counting. Results. Sb-1 titer resulted stable in hemolymph of G. mellonella larvae for 6–8 h post-administration. Two days post-infection of K-wire implanted larvae, ≈5×10. 7. CFU/ml MRSA were found on the material. K-wires from larvae treated with Sb-1 or Daptomycin showed a MRSA CFU/ml reduction of ≈1 log compared to the CFU/ml values of the untreated control. The staggered administration Sb-1/Daptomycin determined higher CFU reduction (≈ 3.5 log). Prophylaxis with Sb-1 prevented MRSA infection of 7out of 10 larvae similarly to vancomycin. Conclusions. G. mellonella larvae implanted with K-wires are a suitable model to test antibiofilm formulations in vivo. Sb-1 phage is able to prevent implant-associated infection due to MRSA in larvae. Sequential combination of Sb-1 and Daptomycin strongly reduces the MRSA load on implanted K-wires


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 146 - 146
1 May 2016
Yuenyongviwat V Ingviya N Pathaburee P Tangtrakulwanich B
Full Access

Background. Vancomycin and fosfomycin are antibiotic commonly used in Methicillin-resistant Staphylococcus aureus (MRSA) infection. This study compares the efficacy of articulating cement spacer implegnated with vancomycin and articulating cement spacer implegnated with fosfomycin to inhibit MRSA. Methods. Vancomycin implegnated articulating cement spacers and Fosfomycin implegnated articulating cement spacers were immersed in sterile phosphate buffered saline(PBS) and then incubated at 37 C. The samples were collected and change daily. Aliquots were tested for MRSA inhibition by disc diffusion method. The inhibition zones diameters were measured. Results. Vancomycin group showed an MRSA inhibition zone up to four weeks. However, Fosfomycin group showed inhibition zone in day 3 in some samples but after that no sample had the potential to inhibit MRSA. Conclusion. In this experiment. Vancomycin impregnated articulating cement spacers showed longer efficacy to inhibit MRSA when compared to Fosfomycin


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 45 - 45
1 Dec 2018
Bue M Hanberg P Koch J Jensen LK Lundorff M Aalbæk B Jensen HE Søballe K Tøttrup M
Full Access

Aim. The increasing incidence of orthopaedic methicillin-resistant Staphylococcus aureus (MRSA) infections represents a significant therapeutic challenge. Being effective against MRSA, the role of vancomycin may become more important in the orthopaedic setting in the years to come. Nonetheless, vancomycin bone and soft tissue penetration during infection remains unclear. We assessed the effect of a traumatically induced, implant-associated acute osteomyelitis on vancomycin bone penetration in a porcine model. Method. In eight pigs, implant-associated osteomyelitis was induced on day 0, using a Staphylococcus aureus strain. Following administration of 1,000 mg of vancomycin on day 5, vancomycin concentrations were obtained with microdialysis for eight hours in the implant bone cavity, in cancellous bone adjacent to the implant cavity, in subcutaneous adipose tissue (SCT) adjacent to the implant cavity, and in healthy cancellous bone and healthy SCT in the contralateral leg. Venous blood samples were also obtained. The extent of infection and inflammation was evaluated by post-mortem computed tomography scans, C-reactive protein serum levels and cultures of blood and swabs. Results. In relation to all the implant cavities, bone destruction was found. Ranging from 0.20 to 0.74, tissue penetration, expressed as the ratio of tissue to plasma area under the concentration-time curve from 0 to the last measured value, was incomplete for all compartments except for healthy SCT. The lowest penetration was found in the implant cavity. Conclusions. Staphylococcus aureus implant-associated osteomyelitis was found to reduce vancomycin bone penetration, especially in the implant cavity. These findings suggest that it may be unsafe to rely solely on vancomycin therapy when treating acute osteomyelitis. Particularly when metaphyseal cavities are present, surgical debridement seems necessary


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 75 - 75
1 Dec 2019
Boot W Foster A Schmid T D'este M Zeiter S Eglin D Richards G Moriarty F
Full Access

Aim. Implant-associated osteomyelitis is a devastating complication with poor outcomes following treatment, especially when caused by antibiotic-resistant bacteria such as methicillin-resistant Staphylococcus aureus (MRSA). A large animal model of a two-stage revision to treat MRSA implant-associated osteomyelitis has been developed to assess novel treatments. A bioresorbable, thermo-responsive hyaluronan hydrogel (THH) loaded with antibiotics has been developed and our aim was to investigate it´s in vivo efficacy as a local antibiotic carrier compared to the current standard of care i.e. antibiotic-loaded polymethylmethacrylate (PMMA) bone cement. Method. 12 female, 2 to 4 year old, Swiss Alpine Sheep were inoculated with MRSA at the time of intramedullary nail insertion in the tibia to develop chronic osteomyelitis. After 8 weeks sheep received a 2-stage revision protocol, with local and systemic antibiotics. Group 1 received the gold standard clinical treatment: systemic vancomycin (2 weeks) followed by rifampicin plus trimethoprim/sulfamethoxazole (4 weeks), and local gentamicin/vancomycin via PMMA. Group 2 received local gentamicin/vancomycin delivered via THH at both revision surgeries and identical systemic therapy to group 1. Sheep were euthanized 2 weeks following completion of antibiotic therapy. At euthanasia, soft tissue, bone, and sonicate fluid from the hardware was collected for quantitative bacteriology. Results. Sheep tolerated the surgeries and both local and systemic antibiotics well. Gold standard of care successfully treated 3/6 sheep with a total of 10/30 culture-positive samples. All 6 sheep receiving antibiotic-loaded THH were successfully treated with 0/30 culture-positive samples, p=0.0008 gold-standard vs. hydrogel (Fisher's Exact). Conclusions. The clinical gold standard treatment was successful in 50% of sheep, consistent with outcomes reported in the literature treating MRSA infection. The antibiotic-loaded THH clearly outperformed the gold standard in this model. Superior efficacy of the THH is likely due to 1) the ability to administer local antibiotics at the both revision surgies due to the bioresorbable nature of the hydrogel, and 2) complete antibiotic release compared to bone cement, which is known to retain antibiotics. Our results highlight the potential of local delivered, biodegradable systems for antibiotics for eradicating implant-related infection caused by antibiotic-resistant pathogens. Acknowledgement. Funding provided by AO Trauma


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 48 - 48
1 Dec 2019
Afonso R Baptista MX Costa MRD Sá-Barros C Santos BD Varanda P Tinoco JB Rodrigues EB
Full Access

Aim. This study aims to describe our department experience with single stage revision (SSR) for chronic prosthetic-joint infection (PJI) after total hip arthroplasty (THA) between 2005 and 2014 and to analyze success rates and morbidity results of patients submitted to SSR for infected THA according to pathogen. Method. We retrospectively reviewed our 10 years of results (2005–2014) of patients submitted to SSR of the hip combined with IV and oral antibiotic therapy for treatment of chronic PJI (at least 4 weeks of symptoms), with a minimum follow-up of four years (n=26). Patients were characterized for demographic data, comorbidities, identified germ and antibiotic therapy applied (empiric and/or targeted). Outcomes analyzed were re-intervention rate (infection-related or aseptic), success rate (clinical and laboratory assessment), length of stay, morbidity and mortality outcomes. Results. In this period, 26 single-stage revisions for chronic PJI of the hip were performed. Patients average age was 72 years (range 44–82). Ten patients were women. The average time of follow up was 69 months (range 4 to 12 years). The most commonly isolated bacteria were coagulase-negative Staphylococci (30%), methicillin-resistant Staphylococcus aureus (MRSA) (18%) and methicillin-sensitive Staphylococcus aureus (15%). It wasn't possible to identify the germ in 19% of the patients and other 23% were polymicrobial. Targeted antibiotic therapy was administered to 73% of patients and the most used targeted antibiotics were Vancomycin (53%), Linezolid (32%) and Rifampicin (21%). Mean length of stay was 25 days. In the follow-up period, 9 patients (35%) required a re-intervention for infection relapse. Two patients (8%) needed surgery because of persistent instability. During the follow-up period, the infection-free survival was 65% (33% for MRSA; 82% for coagulase-negative Staphylococci) and the surgery-free survival was 62%. Six patients (23%) died during the follow-up, all due to other medical conditions not related to hip infection. Conclusions. Our experience suggests that SSR is associated with good outcomes and low re-intervention rate, except in the case of infection due to MRSA. In this last group, the results were significantly poorer, what leads to suggest that a two-stage revision may be a better option. The potential advantages of a SSR include good rates of infection eradication, a decrease in surgical morbidity and mortality as well as a decrease in healthcare and global economic costs. As such, a one-stage aggressive surgical attitude in addition to targeted antibiotherapy seems to be a suitable solution in selected patients


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 48 - 48
1 Dec 2018
Cunha M Murça MA Nigro S Klautau G Salles M
Full Access

Aim. We aimed to compare the in vitro antibacterial activity of Bioactive Glass (BAG) S53P4, which is a compound showing local antibacterial activity, to that of antibiotic-loaded polymethylmethacrylate (PMMA) against multidrug resistant bacteria from osteomyelitis (OM) and prosthetic joint infection (PJI) isolates. Method. We studied convenience samples of multidrug resistant (MDR) microorganisms obtained from patients presenting OM and prosthetic joint infection (PJI). Mixtures containing tryptic soy broth (TSB) and inert glass beads (2mm), BAG-S53P4 granules (0.5–0.8mm and <45 mm) and Gentamicin or Vancomycin-loaded PMMA beads were inoculated with methicillin-resistant Staphylococcus aureus (MRSA) and methicillin-resistant coagulase-negative Staphylococcus (MR-CoNS), Pseudomonas aeruginosa or Klebsiella pneumoniae isolates. Glass beads (2.0mm) were used as a control. Antibacterial activity was evaluated by means of time-kill curve, through seeding the strains on blood agar plates, and subsequently performing colony counts after 24, 48, 72, 96, 120 and 168 hours of incubation. Differences between groups were evaluated by means of two-way analysis of variance (ANOVA) and Bonferroni's t test. Results. Inhibition of bacterial growth started soon after 48 hours of incubation, reached zero CFU/ml between 120 and 168 hours of incubation for both antibiotic-loaded PMMA and BAG S53P4 groups, in comparison with inert glass (p< 0.05). No difference regarding time-kill curves between antibiotic-loaded PMMA and BAG S53P4 was observed. Moreover, despite no difference was observed between both Vancomycin - or Gentamicin-loaded PMMA and BAG groups, there was statistical difference between the effectiveness of all treatments (BAG included) against gram-positive cocci and gram-negative bacilli, the latter of which requiring longer time frames for the cultures to yield no bacterial growth. Conclusions. BAG S53P4 presented antibacterial properties as much as antibiotic-loaded PMMA for MDR bacteria producing OM and PJI, although presenting differences between its effectiveness against different bacterial groups


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 57 - 57
1 Dec 2019
Bezstarosti H van Lieshout E Voskamp L Croughs P Kortram K McNally M Metsemakers W Verhofstad M
Full Access

Aim. The aim of this systematic review was to determine all cultured bacteria, antibiotic strategies, and their outcome from literature describing treatment of FRI patients between 1990 and 2018. Methods. A systematic literature search was performed on treatment and outcome of FRI. All studies in English that described surgical patient series for treatment of FRI were included, using Medline, Embase, Web of Science, Cochrane, and Google Scholar. Publications before 1990 and studies that did not describe FRI patient treatment or did not report original data (e.g., reviews or meta-analyses) were excluded. Study selection and data collection were done by two authors independently. Main collected parameters were preoperative cultures, use of local antibiotics, postoperative antibiotic protocol, cultured microorganisms, and overall outcome of treatment, i.e., eradication of infection and bony union, recurrence, amputations, revisional surgery, and number of complications. Dichotomous data were pooled using Medcalc, and weighted means were calculated for continuous data using Excel. Results. 2,171 studies were identified. Of these, 110 studies were included, describing 119 patient series, in which 4561 patients (4614 fractures) were treated. The population was predominantly male (76%), and the main location of FRI was the tibia (69%). In 78 (71%) studies, 3,234 microorganisms were cultured, of which Methicillin-sensitive Staphylococcus aureus (MSSA) was found in 1,094 (34%) patients, followed by Coagulase-negative Staphylococci (CNS), 431 (13%), Methicillin-resistant Staphylococcus aureus (MRSA), 283 (9%), and Pseudomonas aeruginosa 276 (9%). Polymicrobial infections were present in 11% of patients. Local antibiotics were used in 63 (53%) patient series, with PMMA being the most frequent carrier (73%). Calcium-based cements were used in nine series (14%). Clear postoperative antibiotic protocols were described in only 39 (35%) studies and differed widely. Bony union and infection eradication were achieved in 92% (CI 90–94) of all patients. Recurrence was seen in 9% (CI 8–11), and amputation was required in 3% (CI 3–4) of patients. The effect of local antibiotics on overall outcome of FRI treatment was unclear. Conclusions. This systematic literature review clearly shows that standardized antibiotic treatment protocols for FRI patients are lacking and that internationally accepted guidelines are required. The data also confirm that S. aureus is the most common microorganism encountered in FRI. Due to the large heterogeneity of used local antibiotics and carriers, a reliable comparison was not feasible. Indications for the use of local antibiotics are unclear, and future prospective studies seem necessary


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 24 - 24
1 Dec 2019
Butini ME Abbandonato G Rienzo CD Trampuz A Luca MD
Full Access

Aim. Most orthopedic infections are due to the microbial colonization of abiotic surfaces, which evolves into biofilm formation. Within biofilms, persisters constitute a microbial subpopulation of cells characterized by a lower metabolic-activity, being phenotipically tolerant to high concentrations of antibiotics. Due to their extreme tolerance, persisters may cause relapses upon treatment discontinuation, leading to infection recalcitrance hindering the bony tissue regeneration. Using isothermal microcalorimetry (IMC), we aimed to evaluate in vitro the presence of persisters in a methicillin-resistant Staphylococcus aureus (MRSA) biofilm after treatment with high concentrations of vancomycin (VAN) and their ability to revert to a normal-growing phenotype during incubation in fresh medium without antibiotic. Moreover, the ability of daptomycin to eradicate the infection by killing persisters was also investigated. Method. A 24h-old MRSA ATCC 43300 biofilm was exposed to 1024 µg/ml VAN for 24h. Metabolism-related heat of biofilm-embedded cells, either during or after VAN-treatment, was monitored in real-time by IMC for 24 or 48h, respectively. To evaluate the presence of VAN-derived “persisters” after antibiotic treatment, beads were sonicated and detached free-floating bacteria were further challenged with 100xMIC VAN (100 µg/ml) in PBS+1% Cation Adjusted Mueller Hinton Broth (CAMHB).. Suspensions were plated for colony counting. The resumption of persister cells' normal growth was analysed by IMC on dislodged trated cells for 15h in CAMHB. Activity of 16 µg/ml daptomycin was assessed against persister cells by colony counting. Results. When incubated with 1024 µg/ml VAN, MRSA biofilm produced undetectable heat, suggesting a strong reduction of cell viability and/or cellular metabolism. However, the same samples re-inoculated in fresh medium produced a detectable and delayed metabolism-related heat signal, similarly to that generated by persister cells. The following exposure to 100xMIC VAN resulted in neither complete killing nor bacterial growth, strongly supporting the hypothesis of a persistent phenotype. IMC analysis indicated that VAN-treated biofilm cells resumed normal growth with a ∼3h-delay, as compared to the untreated growth control. Daptomycin treatment yielded a complete eradication of persister cells selected after VAN treatment. Conclusions. Hostile environmental conditions (e.g. high antibiotic bactericidal concentrations) select for persister cells in MRSA biofilm after 24h-treatment in vitro. A staggered treatment vancomycin/daptomycin allows complete biofilm eradication. These results support the use in clinical practice of a therapeutic regimen based on the combined use of antibiotics to kill persisters and eradicate MRSA biofilms. IMC represents a suitable technique to detect persisters and characterize in real-time their reversion to a metabolically-active phenotype


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1401 - 1406
1 Nov 2008
Patel A Calfee RP Plante M Fischer SA Arcand N Born C

Methicillin-resistant Staphylococcus aureus (MRSA) has become a ubiquitous bacterium in both the hospital and community setting. There are two major subclassifications of MRSA, community-acquired and healthcare-acquired, each with differing pathogenicity and management. MRSA is increasingly responsible for infections in otherwise healthy, active adults. Local outbreaks affect both professional and amateur athletes and there is increasing public awareness of the issue. Health-acquired MRSA has major cost and outcome implications for patients and hospitals. The increasing prevalence and severity of MRSA means that the orthopaedic community should have a basic knowledge of the bacterium, its presentation and options for treatment. This paper examines the evolution of MRSA, analyses the spectrum of diseases produced by this bacterium and presents current prevention and treatment strategies for orthopaedic infections from MRSA


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 8 - 8
1 Dec 2018
Vuorinen M Palanne R Mäkinen T Leskinen J Huotari K
Full Access

Aim. Dexamethasone is often used as part of multimodal analgesia to prevent postoperative nausea and vomiting (PONV) and also to reduce postoperative pain. Because glucocorticoids have immunosuppressive and glucose-rising effects, the aim of current study was to examine if dexamethasone may be used safely in arthroplasty surgery. Methods. All consecutive total primary and revision hip and knee arthroplasties performed in the Hospital District of Helsinki and Uusimaa, Peijas Hospital were analyzed (n=18 872). Emergency operations, for example total hip arthroplasties for femur fractures, were also included. Prospective surveillance for postoperative infections was performed. All infections meeting the Musculoskeletal Infection Society definition for prosthetic joint infection (PJI) were included. Results. A total of 189 (1.0%) PJIs occurred: 0.8% after all primary arthroplasties and 1.9% after revision arthroplasties. The PJI rate after the emergency operations was 2.3 % (19/796). The PJI rate in the dexamethasone group was 1.0% (30/2 922) and in the non-dexamethasone group 1.0% (159/15 950), with no significant difference in the PJI incidence (P=0.849). The median time from the index operation to the infection was 16.0 (Q1–Q3 13.0–23.0) days. Total of 35 causative bacteria were cultured from the 30 PJI in dexamethasone group and 169 bacteria from the 159 PJI in non-dexamethasone group with no significant difference: Staphylococcus aureus (40.0% and 45.0%, respectively, P=1.000), Staphylococcus epidermidis (14.3% and 10.7%, P=0.375), other coagulase-negative staphylococci (11.4% and 11.8%, P=0.200), Streptococcus agalactiae (11.4% and 11.8%, P=0.695), Streptococcus betahemolyticus G (8.6% and 2.4%, P=0.081), other streptococci (0.0% and 4.1%, P=0.599), Enterococcus faecalis (2.9% and 5.3%, P=1.000), Enterobacter cloacae (2.9% and 3.6%, P=1.000), Pseudomonas aeruginosa (2.9% and 1.8%, P=0.502), and other bacteria (14.3% and 8.8%, P=0.544). Only one methicillin-resistant Staphylococcus aureus (MRSA) was detected in dexamethasone group. The proportion of polymicrobial PJIs was similar in both groups: 13.3% and 8.8%, respectively (p=0.495). Conclusions. In our study material, the use of 5–10mg dose of dexamethasone did not increase the incidence of postoperative PJI. The single 5–10 dose of dexamethasone may be safely used to prevent PONV and as part of multimodal analgesia on patients undergoing arthroplasty operation


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 8 - 8
1 Dec 2017
Tkhilaishvili T Di Luca M Trampuz A Gaudias J
Full Access

Aim. The increase of antimicrobial resistance reduces treatment options for implant-associated infections caused by methicillin-resistant Staphylococcus aureus (MRSA). Bacteriophages present a promising alternative to treat biofilm-related infections due to their rapid bactericidal activity and activity on multi-drug resistant bacteria. In this study, we investigated the synergistic activity of lytic bacteriophage Sb-1 with different antibiotics against MRSA biofilm, using a real-time highly sensitive assay measuring growth-related heat production (microcalorimetry). Methods. Rifampin, fosfomycin, vancomycin and daptomycin were tested alone and in combination with S. aureus specific phage, Sb-1, against MRSA (Staphylococcus aureus*). MRSA biofilm was formed on porous glass beads (Φ 4 mm, pore size 60 µm) and incubated for 24 h at 37° C in BHI. After 3 times washing biofilms were exposed first to different titers of bacteriophages, ranging from 102 to104 plaque-forming unite (pfu)/ml and after 24h treated again with subinhibitory concentration of antibiotics (corresponding to 1/4, 1/8, 1/16, 1/32 × MHICbiofilm). After 24h antibiotic treatment, the presence of biofilm on glass beads was evaluated by isothermal microcalorimetry for 48h. Heat flow (µW) and total heat (J) were measured. Results. MHICs of rifampin, fosfomycin, daptomycin and vancomycin when tested alone were 256 μg/ml, >4096 μg/ml, 128μg/ml and 2048μg/ml, respectively. Synergistic activity against biofilm MRSA was observed when vancomycin was tested at subinhibitory concentrations 512 μg/ml, 256 μg/ml, 128 μg/ml and 64 μg/ml in combination with subinhibitory titers of Sb-1 at 102, 103, 104 pfu/ml. Complete inhibition of heat production was observed only in combination with a higher titer of Sb-1 (104 pfu/ml). High synergistic activities were also observed in the presence of rifampin, fosfomycin and daptomycin. Conclusions. While MHICs of antibiotics against MRSA biofilm were above drug concentrations reachable in clinical practice, the co-administration with bacteriophage Sb-1 strongly reduced the antibiotic doses needed to eradicate MRSA biofilm. The use of bacteriophage and antibiotics in combination represent an effective strategy to treat implant-associated infections


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 20 - 20
1 Dec 2016
Ezzat A Lovejoy J Alexander K
Full Access

Aim. North America is facing a rising epidemic involving strains of methicillin-resistant Staphylococcus aureus (MRSA) that, instead of being found almost exclusively in hospitals, are community-associated (CA-MRSA). These strains are aggressive, associated with musculoskeletal manifestations including osteomyelitis (OM), and septic arthritis (SA). We aimed to establish novel management algorithms for acute OM and SA in children. We investigated S.aureus susceptibilities to current first-line antimicrobials to determine their local efficacy. Method. The project was conducted at Nemours General Children Hospital in Florida, USA, following approval by the internal review board. A literature review was conducted. An audit of S.aureus antimicrobial sensitivities was completed over three years and compared against national standards. Susceptibilities of clindamycin, trimethoprim/sulfamethoxazole (TMP/SMX) and vancomycin were studied using local resistance ranges. Results. Two algorithms for acute OM and SA management were created adopting a multidisciplinary team approach from admission to discharge whilst differentiating higher risk patients within fast-track pathways. We analysed 532 microbiology results for antibiotic susceptibilities from 2012 to 2014. Overall, 51% of S.aureus infections were MRSA versus 49% methicillin-susceptible S.aureus (MSSA). Surprisingly, clindamycin resistance rates rose compared to 2005 (MRSA 7% in 2005 vs 39% currently, MSSA 20% vs 31% and total S.aureus resistance rate of 8% vs 35%, respectively). MRSA and MSSA isolates were near 100% sensitive to Vancomycin and TMP/SMX. No appropriate national standards existed. Conclusions. Multidisciplinary based algorithms were created for acute OM and SA treatment in children. Possible therapeutic roles for ultrasound guided aspiration and corticosteroids were highlighted in SA. Our audit revealed equal incidence of MSSA to MRSA, supporting national figures on falling MRSA. Interestingly, increased resistance of MSSA and MRSA was found towards recommended first line clindamycin, raising concern over its efficacy


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 75 - 75
1 Dec 2016
Butini ME Trampuz A Di Luca M
Full Access

Aim. To investigate the antimicrobial activity of a gentamicin-loaded bone graft substitute (GLBGS) in the prevention and eradication of bacterial biofilms associated with prosthetic joint infections (PJI). Method. The GLBGS (17,5 mg gentamicin/ml paste) with 40% hydroxyapatite/60% calcium sulfate. 1. was tested against biofilms of methicillin-resistant Staphylococcus aureus (MRSA) ATCC 43300, methicillin-susceptible S. aureus (MSSA) ATCC 29213, Escherichia coli Bj HDE-1, S. epidermidis ATCC 12228 and Enterococcus faecalis ATCC 19433. For prevention studies, glass beads and different combinations of GLBGS were co-incubated for 24h at 37°C in CAMH broth with 1–5 × 10. 6. CFU/mL of bacteria. For eradication, biofilms were formed on glass beads for 24h at 37°C in CAMH broth. Then, beads were incubated with different combinations of GLBGS in medium at 37°C for 24h. For microcalorimetric measurements, beads were placed in ampoules and heat flow (µW) and total heat (J) were measured at 37°C for 24h. The minimal heat inhibitory concentration (MHIC) was defined as the lowest gentamicin concentration reducing the heat flow peak by ≥90% at 24h. Results. The GLBGS showed a good activity against all tested strains in both biofilm prevention and eradication. All MHIC values are reported in Table 1. Lower MHICs were observed when GLBGS was tested against E. coli (9.6 µg/mL prevention and 19.2 µg/mL eradication) and S. epidermidis (86 µg/mL and 38.8 µg/mL, respectively). For both prevention and eradication of MSSA, GLBGS MHIC was 631 µg/mL. E. faecalis biofilm formation was prevented with 631 µg/mL and eradicated with double concentration. MRSA showed a higher resistance to GLBGS up to 2516 µg/mL, both in biofilm prevention and eradication. Conclusions. This GLBGS is a valid composite for the prophylaxis and treatment of PJI. Further studies will be performed to evaluate the activity of higher concentrations of GLBGS against MRSA. 1. CERAMENT™|G, BONESUPPORT AB, Sweden


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 199 - 199
1 Mar 2013
Hirose S Otsuka H Morishima T
Full Access

Introduction. We report our mid-term results and risk factors of a two-stage revision using impaction bone grafting for an infected hip replacement. Methods. A two-stage revision using impacted cancellous allografs and cement was performed in 13 patients (7 total hip replacements, 6 femoral head replacements) with confirmed infection. The mean age of the patients at first stage operation was 63 years (range, 45–84 years). In the first stage, local antibiotics were added to customized cement beads and/or a cement spacer after removal of all components and radical debridement. In the second stage, impaction grafting was done using the X-change system (Exeter). Results. Of the patients, 8 underwent multiple operations to obtain evidence that infection had been overcome in the first stage, and of them, 6 had infection due to methicillin-resistant Staphylococcus aureus (MRSA). The mean duration from first stage operation to second stage revision was 8 months (range, 3–17 months). Only one patient suffered re-infection due to MRSA after second stage revision, which was not the original infecting agent, and the other 12 patients had satisfactory radiological outcomes. The success rate was 92% at the mean follow-up of 4 years (range, 1–10 years) after revision. Conclusion. Allograft bone was shown to be useful for infected hip replacement with a considerable loss of bone stock. We considered that control of MRSA infection is a key factor for successful outcome


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 90 - 90
1 Apr 2017
Ezzat A Lovejoy J Alexander K
Full Access

Background. North America is facing a rising epidemic involving strains of methicillin-resistant Staphylococcus aureus (MRSA) that, instead of being found almost exclusively in hospitals, are community-associated (CA-MRSA). These strains are aggressive, associated with musculoskeletal manifestations including osteomyelitis (OM), and septic arthritis (SA). We aimed to establish novel management algorithms for acute OM and SA in children. We investigated S.aureus susceptibilities to current first-line antimicrobials to determine their local efficacy. Methods. The project was conducted at Nemours Children Hospital in Florida, USA, following approval by the internal review board. A literature review was conducted. An audit of S.aureus antimicrobial sensitivities was completed over three years and compared against national standards. Susceptibilities of clindamycin, trimethoprim/sulfamethoxazole (TMP/SMX) and vancomycin were studied using local resistance ranges. Results. Two algorithms for acute OM and SA management were created adopting a multidisciplinary team approach from admission to discharge whilst differentiating higher risk patients within fast-track pathways. We analysed 532 microbiology results for antibiotic susceptibilities from 2012 to 2014. Overall, 51% of S.aureus infections were MRSA versus 49% methicillin-susceptible S.aureus (MSSA). Surprisingly, clindamycin resistance rates rose compared to 2005 (MRSA 7% in 2005 vs 39% currently, MSSA 20% vs 31% and total S.aureus resistance rate of 8% vs 35%, respectively). MRSA and MSSA isolates were near 100% sensitive to Vancomycin and TMP/SMX. No appropriate national standards existed. Conclusions. Multidisciplinary based algorithms were created for acute OM and SA treatment in children. Possible therapeutic roles for ultrasound guided aspiration and corticosteroids were highlighted in SA. Our audit revealed equal incidence of MSSA to MRSA, supporting national figures on falling MRSA. Interestingly, incresed resistance of MSSA and MRSA was found towards recommended first line clindamycin, raising concern over its efficacy. Level of Evidence. 5


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 332 - 332
1 Jul 2011
Donaldson A Jalaludin BB Chan RC
Full Access

Introduction: Aside from a technical understanding, patients’ perceptions of, and the emotional associations they make with, their illness can influence the eventual outcome. We explored this in relation to bone and joint infections as these can have major impacts on patients in terms of reduced mobility, need for surgery and long-term antibiotic use. In particular we wanted. to assess how patients viewed their infections,. to see if infection with methicillin-resistant Staphylococcus aureus (MRSA) was different to non-MRSA infections, and. to explore the emotional associations of these infections. Methods: We adapted the Illness Perception Questionnaire of Weinman (1996) for this purpose. We focused on three domains: consequences, control/cure, and emotional responses. We asked all patients with osteomyelitis, septic arthritis or prosthetic joint infection attending the Liverpool Hospital Infectious Diseases Outpatient Clinic between May and August 2005 to complete the questionnaire. Results: Ninety-one patients completed the questionnaire. Thirty-nine had either MRSA infection or colonisation. Overall, most patients felt that their infection had made a major impact on their life (76%) or that their infection was very serious (79%). This negative response was independently associated with younger age and having MRSA (either infection or colonisation). Patients with prosthetic joint infections felt they had reduced sense of control and likelihood of cure. Conclusions: Bone and joint infections have a major psychological impact on patients, especially the young, those with MRSA and those with prosthetic joint infections. Health care professionals should take account of these emotional responses in order to optimise their therapeutic relationship with patients


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 16 - 16
1 Mar 2008
Johnston P Norrish A Brammer T Walton N Coleman N Hegarty T
Full Access

The objective of our study was to assess the efficacy of infection control measures (pre-admission screening and patient segregation) on reducing inpatient exposure to methicillin-resistant Staphylococcus aureus (MRSA). A prospective case-control study was undertaken, analysing all admissions to three wards over an 83-month period from September 1995 to July 2002 inclusive (a total of approximately 34 000 patients). An orthopaedic ward with active infection control measures was compared with two controls, an orthopaedic ward with no measures and a general surgical ward with no measures. A statistical analysis was performed of the difference between the 3 wards in numbers of new cases of MRSA infection or colonisation. There was a statistically significant difference in numbers of new cases between the ward with the active infection control measures and the two control wards. The infection control methods described are shown to reduce the exposure of patients to MRSA, which is of importance in orthopaedics, and has further benefits that may be applied in other surgical specialties, notably the choice of antibiotic used with the associated risk of side-effects of the specific anti-MRSA agents, the cost for surgical prophylaxis and patients’ confidence in the admitting surgical unit. As a useful by-product, such segregated inpatient beds are effectively ring-fenced, ensuring availability even during a hospital bed-shortage


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 75 - 75
1 Mar 2009
Anagnostakos K Hitzler P Pape D Kohn D Kelm J
Full Access

Implantation of antibiotic-loaded beads is accepted as an efficient option for local antibiotic therapy in orthopedic-related infections. However, recent reports have emphasized the bacteria growth persistence on antibiotic-impregnated bone cement. Hence, the aim of this study was to elaborate if bacterial adherence and growth could be determined on explanted gentamicin- and gentamicin-vancomycin-loaded beads after infection eradication. 18 chains of antibiotic-loaded beads (11 gentamicin-, 7 gentamicin-vancomycin-loaded) were examined. Indications for primary beads implantation included postoperative infections after total hip or knee arthroplasty, rotator cuff reconstruction, chronic foot osteomyelitis, anterior cruciate ligament reconstruction and dorsal spondylodesis. Among the isolated organisms, Staphylococcus epidermidis, Staphylococcus aureus and methicillin-resistant Staphylococcus aureus (MRSA) were the most frequent ones. In 4 cases (3 × S. epidermidis, 1 × MRSA) bacteria growth persistence could be determined on the beads. S. epidermidis-strains persisted only on gentamicin-loaded beads, MRSA could grow on gentamicin-vancomycin-impregnated cement. In one case, the emergence of a gentamicin-resistant S. epidermidis-strain could be observed despite preoperative susceptibility. Bacteria growth persistence on bone cement is a hazardous problem in the orthopedic surgery and should therefore be born in mind. Adherence to cement can lead to emergence of bacteria resistance despite preoperative antibiotic susceptibility and might result in clinical recurrence of infection


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 43 - 43
1 Apr 2019
Friedrich CR Baker E Bhosle S Justin D
Full Access

Periprosthetic infection remains a clinical challenge that may lead to revision surgeries, increased spending, disability, and mortality. The cost for treating hip and knee total joint infections is anticipated to be $1.62 billion by 2020. There is a need for implant surface modifications that simultaneously resist bacterial biofilm formation and adhesion, while promoting periprosthetic bone formation and osseointegration. In vitro research has shown that nanotextured titanium promotes osteoblast differentiation, and upregulates metabolic markers of osteoblast activity and osteoblast proliferation. In vivo rat studies confirmed increased bone-implant contact area, enhanced de novo bone formation on and adjacent to the implant, and higher pull-out forces compared to non-textured titanium. The authors have advanced a benign electrochemical anodization process based on ammonium fluoride that creates a nanotube surface in as little as 10 minutes (Fig. 1), which can also integrate antibacterial nanosilver (Fig. 2). The work reported here summarizes in vitro post-inoculation and in vivo post-implantation studies, showing inherent inhibition of methicillin-resistant Staphylococcus aureus (MRSA) by titanium surfaces with nanotubes (TiNT), nanotubes with nanosilver (TiNT+Ag), plain (Ti), and thermal plasma sprayed (TPS) titanium. Ti6Al4V was the base material for all surfaces. In vitro studies evaluated Ti, TPS, four TiNT groups with varying nanotube diameters (60nm, 80nm, 110nm, 150nm), and TiNT+Ag. After seeding with MRSA (10. 5. , 10. 6. , and 10. 8. CFU/mL), the 110nm diameter nanotubes showed MRSA inhibition up to three-orders of magnitude lower than the Ti and TPS surfaces at 2, 6, and 48 hours. Following on the in vitro results, New Zealand White rabbits underwent a bilateral implantation of intramedullary tibial implants of the four material groups (4 mm outside diameter; 110nm NT diameter on TiNT and TiNT+Ag implants). One intramedullary canal was inoculated with clinically-derived MRSA (10. 5. CFU in broth) at the time of implantation; one canal had only culture media introduced (control). At a 2-week endpoint, limbs were harvested for analysis, including implant sonication with sonicant bacterial cultured, histology, and microcomputed chromatography. In the sonicant analysis cohort, TPS showed the lowest average MRSA count, while TiNT and TiNT+Ag were the highest. There was one sample each of TPS, TiNT and TiNT+Ag that showed no MRSA. After an additional 24-hour implant incubation, the TiNT and TiNT+Ag samples had no bacteria, but the TPS grew bacteria; therefore, the authors hypothesize that MRSA more readily releases from the TiNT and TiNT+Ag implants during sonication, indicating weaker biofilm adhesion and development. Histologic analysis is currently underway. In a therapeutic experiment, rabbits underwent bilateral implantation, followed by 1 week of infection development, and then 1 week of vancomycin treatment. At the endpoint, implants were sonicated and bacteria was quantified from the sonicant. TiNT showed viable MRSA at only 30% that of TPS-coated levels, while TiNT+Ag implants showed viable MRSA at only 5% that of TPS-coated levels (Fig. 3). These early results indicate that the TiNT and TiNT+Ag surfaces have some inherent antibacterial activity against MRSA, which may increase the efficacy of systemic antibiotic treatments in the setting of periprosthetic joint infections


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 502 - 502
1 Aug 2008
Kilshaw MJ Curwen C Kalap N
Full Access

Methicillin-resistant Staphylococcus aureus (MRSA) has increased in prevalence and significance over the past ten years. Studies have shown rates of MRSA in Trauma and Orthopaedic populations to be from 1.6% to 38%. Rates of MRSA are higher in long term residential care. It has been Department of Health policy to screen all Trauma and Orthopaedic patients for MRSA since 2001. This study audited rates of MRSA screening in patients who presented with fractured neck of femur treated with Austin Moore hemi-arthroplasty over the course of one year. Rates of MRSA carriage and surgical site infection (SSI) were derived from the computerised PAS system and review of case notes. 9.8 % of patients were not screened for MRSA at any time during their admission. The rate of MRSA carriage within the study population was 9.2%. The MRSA SSI rate was 4.2%. MRSA infections are associated with considerable cost and qualitative morbidity and mortality. There is good evidence for the use of nasal muprocin and triclosan baths in reducing MRSA. Single dose Teicoplanin has been shown to be as effective as traditional cephalosporin regimes. There is new guidance for the use of prophylactic Teicoplanin for prevention of SSI. We should consider introducing both topical and antimicrobial MRSA prophylaxis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 37 - 37
1 Feb 2012
Walley G Orendi J Bridgman S Maffulli N Davies B Ahmed E
Full Access

To describe the prevalence and incidence of Methicillin-resistant Staphylococcus aureus (MRSA) colonisation during the patient journey for patients admitted to orthopaedic and trauma wards, we carried out a prospective audit at the University Hospital of North Staffordshire NHS Trust, England. The Study Population comprised patients admitted to the trauma and elective orthopaedic wards, with an expected stay of 48 hours or more between March and May 2003. Patients were swabbed for MRSA colonisation on ward admission, transfer to another ward and discharge from hospital. Elective patients undergoing major joint surgery were also swabbed at a pre-operative assessment clinic. Colonised patients were treated depending on individual risk assessment. Five hundred and fifty-nine eligible patients were admitted to hospital. Of these, 323 (101 elective, 192 trauma and 30 non-orthopaedic) patients were included in the study, of whom 28 elective patients (28%), 43 trauma patients (22%), and seven non-orthopaedic patients (23%) were colonised with MRSA at any time during the audit period. Of the 80 patients identified as negative for MRSA colonisation at pre-assessment screening and included in the audit, ten (9.5%) were found to be colonised on admission. There is a high prevalence of MRSA colonisation in patients admitted to the orthopaedic and trauma wards in our setting. A policy of pre-admission screening, though able to identify MRSA carriage does not guarantee that patients are not colonised in the period between screening and admission. Consideration should be given to screening all patients for MRSA who are admitted to an orthopaedic ward


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 130 - 130
1 Feb 2004
Cleary M Neligan M Dudeney M Quinlan W
Full Access

Nosocomial infection with methicillin-resistant Staphylococcus aureus (MRSA) is on the increase and is expensive to treat. MRSA surgical wound infection may have disastrous consequences, particularly in an orthopaedic setting. We studied the rate of MRSA colonization in an important subgroup of orthopaedic patients. 50 nursing home residents were retrospectively reviewed with regard to their MRSA status on admission to an orthopaedic ward with fractured neck of femur. As is policy in our institution, all patients from nursing homes or other institutions are screened for MRSA on admission. Of the 50 nursing home patients requiring a hemi-arthroplasty, 16%(8) were MRSA positive. 2%(1/50) acquired MRSA infection while I hospital, while the remaining 14%(7/50) were carriers on admission. 4%(2/50) developed sepsis postoperatively, followed by multiorgan failure and death. 4% had their MRSA cleared prior to discharge, while 8% remained positive on discharge. All patients undergoing hemiarthroplasty received cefuroxime, unless allergic, as prophylaxis at induction. These findings of considerable MRSA carriage in nursing home patients is particularly relevant today, as the number of patients in nursing homes continues to grow as the population ages. The patient population in nursing homes is susceptible to infection because of the physiological changes that occur with ageing, the underlying chronic diseases of the patients and the institutional environment within which residents socialize and live. Nursing home residents presenting to orthopaedic units for surgery are a unique group in repairing careful consideration


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 105 - 105
1 Dec 2015
Metsemakers W Emanuel N Cohen O Reichart M Schmid T Segal D Richards R Zaat S Moriarty T
Full Access

One of the most challenging complications in orthopedic trauma surgery is the development of infection. Improved infection prophylaxis could be achieved by providing local delivery of antibiotics directly to the tissue-implant interface. Especially implant-associated bone infections caused by antibiotic-resistant pathogens pose significant clinical challenges to treating physicians. Prophylactic strategies that act against resistant organisms, such as methicillin-resistant Staphylococcus aureus (MRSA), are urgently required. The objective of this experimental study was to determine the efficacy of a biodegradable Polymer-Lipid Encapsulation MatriX (PLEX) loaded with the antibiotic doxycycline as a local prophylactic strategy against implant-associated osteomyelitis in a humeral non-fracture rabbit model. Activity of the PLEX-doxycycline-coating was tested against both a doxycycline susceptible (doxyS) methicillin-susceptible S. aureus (MSSA) as well as a doxycycline-resistant (doxyR) MRSA. In a rabbit intramedullary (IM) nail-related infection model, twelve rabbits received an inoculum of a doxyS MSSA direct into the medullary cavity of the humerus. After inoculation, animals received either a PLEX-doxycycline-coated nail, or an uncoated nail. The animals were observed for four weeks. Upon euthanasia, quantitative bacteriology was performed to determine bacterial load in tissues and biofilm formation on the implant. A second study was performed with sixteen rabbits receiving a DoxyR MRSA inoculum, again in coated and uncoated groups. In vitro elution studies revealed that 25% of the doxycycline was released from the PLEX-coated implants within the first day, followed by a 3% release per day up to day 28. Quantitative bacteriology revealed the presence of osteomyelitis in all animals receiving an uncoated nail in both the MSSA and the DoxyR MRSA studies (figure). All rabbits receiving a PLEX-doxycycline-coated nail were culture negative in the doxyS MSSA-group and the surrounding bone displayed a normal physiological appearance in both histological sections and radiographs. In the doxyR MRSA inoculated rabbits, a statistically significant reduction in the number of culture-positive samples was observed for the PLEX-doxycycline-coated group when compared to the animals that had received an uncoated nail, although the reduction in bacterial burden did not reach statistical significance. Improved prophylaxis against infection in trauma and orthopedic implant surgery is clearly required today. In this study, we investigated a PLEX-doxycycline-coated IM nail in a humeral non-fracture rabbit model. The PLEX-doxycycline coating on titanium alloy implants provided complete protection against implant-associated MSSA osteomyelitis, and resulted in a significant reduction in the number of culture positive samples when challenged with a doxycycline-resistant MRSA


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 39 - 39
1 Dec 2016
Glombitza M Steinhausen E
Full Access

Aim. Treatment principles of chronic osteomyelitis include debridement, clean sampling, excision of dead bone, stabilization, dead space management, soft tissue closure and systemic antibiotic therapy. Dead space management becomes very complicated, if the bone infection is caused by multi-resistant bacteria. The aim of this investigation was to evaluate the effect of a new vancomycin-loaded hydroxyapatite / calcium sulfate composite. *. in the treatment of chronic osteomyelitis (OM) caused by multi-resistant bacteria. Method. From June 2015 to November 2015, 7 patients (4 males, 3 females, average age 52.6y) were treated according to the above mentioned principles using the new vancomycin-loaded hydroxyapatite / calcium sulfate composite. *. Infections were caused by methicillin-resistant Staphylococcus aureus (MRSA), multi-resistant Staphylococcus epidermidis (MRSE) and polymicrobial, vancomycin-sensitive bacteria. We used a two-stage protocol with debridement, excision of bone and external stabilization in the first stage, followed by bone defect reconstruction. To fill the residual bone defects, in 3 patients the new vancomycin-loaded hydroxyapatite / calcium sulfate composite. *. (10mL) was used on its own and in 4 patients combined with 18mL of an unloaded calcium sulfate / hydroxyapatite composite. **. Post-operative follow-up was evaluated clinically and by radiographs and CT scans at 6, 14 and 24 weeks. Results. In 6 of 7 patients rapid control of infection was achieved. Soft tissue reactions and prolonged white wound drainage (caused by calcium sulfate dissolution) was seen in 3 of 7 patients. In 6 of 7 patients recurrence of infection has not been observed so far. Radiographs showed different elution intervals of the radiocontrast agent (Iohexol), depending on anatomical location. Bone remodelling or replacement of the composite by new bone was not uniform in the patients and showed specific radiographic signs. In addition to the so-called „puddle sign“, we found septae, membranes, vacuoles and sometimes arc-like structures. Therefore, we suggest the name “arc-sign” for these formations. Conclusions. During the follow-up of the first 7 patients treated with the unloaded calcium sulfate / hydroxyapatite composite. **. in 6 of 7 cases no recurrence of infection was observed. This is very promising in the difficult situation of bone infections caused by multi-resistant bacteria. Follow-up radiographs and CT-scans showed specific patterns during the resorption of the composite and the formation of new bone, which have not been described in other bone graft substitutes so far. The bone defects are not completely filled yet, but the affected bones are clinically stable and patients can ambulate with full weight bearing


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 218 - 218
1 Mar 2003
Dailiana Z Petinaki E Kontos F Maniatis A Malizos K
Full Access

Purpose: The purpose of this study was to evaluate the prevalence of methicillin-resistant Staphylococcus aureus (MRSA) isolates in the Orthopaedic Department of a new University Hospital, two years from its opening. Material and Methods: Forty-three consecutive S. aureus isolates, collected from cultures (pus 90%) from consecutive orthopaedic inpatients were included in the study. Resistance to antimicrobial agents was assessed by the disk diffusion method. The mecA-gene was detected by PCR assay, whereas molecular typing of the isolates was performed by PFGE. Results: Only 5 of the 43 strains (11.6%) expressed high level resistance to oxacillin (MIC ≥ 64mg/L). All these isolates possessed mecA-gene and exhibited resistance, except oxacillin, to more than four classes antimicrobial groups. The remaining 38 isolates (34 beta-lactamase positive) were susceptible to oxacillin (MIC ≤ 2mg/D, and expressed a less resistant type than that of MRSA. Molecular typing by PFGE showed apparent heterogeneity among isolates and the absence of predominant clones. Conclusions: The 11.6% prevalence of MRSA is well below the reported average in the literature. Apparently the isolates originated from different sources of contamination. All patients had previous hospitalizations, where they acquired the infections and subsequently transferred the MRSAs to our department. Precautions and measures taken in the wards limited the spread and dissemination of the isolates as demonstrated by the heterogeneity and the absence of predominant clones. These findings further reiterate the value of the low-cost, standard preventive procedures to control nosocomial infections in a high-risk orthopaedic department


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 59 - 60
1 Mar 2010
Edis* E Scammell B Bayston R
Full Access

Prosthetic joint infection (PJI) is an increasing problem and management commonly involves prosthesis removal with serious consequences. Biofilm-forming staphylococci are the most common causative organisms with Staphylococcus aureus being most virulent and methicillin-resistant Staphylococcus aureus (MRSA) more than doubling the infection mortality rate. Bacterial adhesion is an essential primary event in biofilm formation and infection establishment. The development of a novel combination vaccine programme to prevent staphylococcal PJI by directing antibody against factors involved in adhesion and biofilm formation, and investigation of S. aureus binding-domains as potential vaccine components for adhesion inhibition is described. Selected target antigens included the S. aureus fibronectin-binding protein (FnBP) and iron-regulated surface determinant (IsdA), which have been shown to be important for infection establishment and predominantly bind to host fibronectin and fibrinogen respectively. Escherichia coli clones harbouring recombinant S. aureus binding-domain DNA sequences were used for expression and purification of antigen domains. In vitro antibody evaluation determined whether immune inhibition of bacteria - ligand binding can significantly impact on attachment to plasma-conditioned biomaterial (in presence of other bacterial ligands). Adhesion of homologous and heterologous (MRSA PJI isolate) S. aureus to plasma-conditioned steel was significantly reduced (approximately 50 percent average reduction, p < 0.0001) when pre-exposed to anti-rFnBP-A antiserum (with pre-immune serum control) that was 50-fold more dilute than the actual titre from immunisation. Inhibition was related to ligand presence but not staphylococcal Protein A, and reduced adhesion was not observed with the mutant strain, indicating specific inhibitory antibody involvement, and demonstrating for the first time the potential of rFnBP-A for prevention of S. aureus PJI. Adhesion-inhibitory activity was also observed with a purified IgG-fraction of rIsdA antiserum but this activity appeared to be masked by non-IsdA - related interactions when non-IgG - purified antiserum was assessed


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 170 - 170
1 Jun 2012
Whiteside L Peppers M Nayfeh T Roy M
Full Access

Introduction. Resistant organisms are difficult to eradicate in infected total knee arthroplasty, and treatment of methicillin-resistant Staphylococcus aureus (MRSA) is especially challenging. Whereas most surgeons use antibiotic-impregnated cement during revision to treat infection, the delivery of the drug in adequate doses is limited in penetration and duration. This study presents the 2- to 8-year prospective results of one-stage revision and intraarticular antibiotic infusion protocol used to treat MRSA. Methods. Eighteen knees (18 patients) with methicillin-resistant Staphylococcus aureus were treated between January 2001 and January 2007 with one-stage revision protocol that included débridement, uncemented revision of total knee components, and intraarticular infusion of 500 mg vancomycin via Hickman catheter once or twice daily for 6 weeks. (Figure 1) No intravenous antibiotics were used after the first 24 hours. Serum vancomycin levels were monitored to maintain levels between 3 and 10 μg/mL. The mean serum vancomycin peak concentration was 6 ± 2 μg/mL and the mean serum vancomycin trough concentration was 3 ± 1 μg/mL at 2 weeks postoperative. Results. Knee synovial fluid peak and trough vancomycin levels were measured in two knees. Synovial fluid peak concentrations were 10,233 μg/mL and 20,167 μg/mL and trough concentrations were 724 μg/mL and 543μg/mL, respectively. Minimum followup was 27 months (range, 27-75 months). Mean followup was 62 months, (range, 27–96 months). At 2-year followup, mean Knee Society score was 83 ± 9. No radiographic evidence of implant migration has occurred. One knee became reinfected with methicillin-resistant Staphylococcus aureus and was reoperated at 5 months. A necrotic bone segment was found, the knee was debrided and revised, and the antibiotic infusion protocol was readministered. The knee remained free of infection at 42 months postoperatively. Conclusions. One-stage revision with uncemented components and 6 weeks intraarticular vancomycin administration safely and effectively treated MRSA-infected TKA with no apparent complications


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 314 - 314
1 May 2010
Efstathopoulos N Nikolaou V Tsiolis P Lazarettos I Tsaganos T Koutoukas P Frangia K Korres D Giamarellosbourboulis E
Full Access

Introduction: Biodegradable systems releasing antibiotics are promising candidates for the management of chronic osteomyelitis. Gentamicin and fluoroquinolones are the commonest antibiotics applied with these systems. The effectiveness of a new system from polymerized dilactide (PLA) with incorporated linezolid has been investigated in a rabbit model for treating osteomyelitis by methicillin-resistant Staphylococcus Aureus (MRSA). Methods: The PLA – Linezolid system was made after thorough stirring 2gr of polymer with 100 mg of linezolid. Experimental osteomyelitis was established in 40 rabbits by a modification of the Norden model. Methicillin-resistant Staphylococcus aureus (MRSA) was applied as the test isolate. After drilling a hole in the upper right femur, the isolate was inoculated along with a thin needle working as a foreign body. After three weeks the needle was removed and cultured and PLA-Linezolid system was implanted in half of the animals. Animals were sacrificed at regular time intervals and tissue around the site of implantation was sent for histologic examination and quantitative cultures. Results: At 2 – 4 – 6 – 8 – 10 weeks time after removal of the needle results (mean values) were as follows (Controls/PLA-Linezolid): Log10 (cfu/g) at infection site: 2.99/5.68 – 3.44/3.20 – 3.22/2.39 – 1.00/1.27 – 1.00/1.00 respectively and Δlog10 (cfu/g) compared to start: −0.05/−3.23 – 0.23/0.13 – 0.05/0.93 – 1.34/1.09 – 3.31/3.34 respectively. Histology confirmed the previous mentioned results, showing an early decrease following by late recurrence of the infectious reaction at the animals that PLA-Linezolid system was used. Conclusions: It is concluded that the applied system achieved an early decrease of the tissue bacterial load which was not maintained until late on follow-up. This might be explained by the bacteriostatic mode of action of linezolid


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 242 - 242
1 Dec 2013
Williams D Vinciguerra J Lerdahl J Bloebaum R
Full Access

Introduction:. Periprosthetic infections that accompany the use of total joint replacement devices cause unwanted and catastrophic outcomes for patients and clinicians. These infections become particularly problematic in the event that bacterial biofilms form on an implant surface. Previous reports have suggested that the addition of Vitamin E to ultra-high-molecular-weight polyethylene (UHMWPE) may prevent the adhesion of bacteria to its surface and thus reduce the risk of biofilm formation and subsequent infection. 1–3. In this study, Vitamin E was blended with two types of UHMWPE material. It was hypothesized that the Vitamin E blended UHMWPE would resist the adhesion and formation of clinically relevant methicillin-resistant Staphylococcus aureus (MRSA) biofilms. Methods and Materials:. Five sample types were manufactured, machined and sterilized (Table 1). To determine if MRSA biofilms would be reduced or prevented on the surface of the Vitamin E (VE) loaded samples (HXL VE 150 kGy and HXL VE 75 kGy) in comparison to the other three clinically relevant material types, each was tested for biofilm formation using a flow cell system. 4. Direct Bacterial Quantification – An n = 7 samples of each material type were placed individually into a chamber of the flow cell. A solution of 10% modified brain heart infusion (BHI) broth containing 10. 5. MRSA cells/mL was flowed through each chamber. Using previously established protocols,. 4–7. after 48 hours of growth, each sample was removed, and the number of colony forming units (CFU) determined using a 10-fold dilution series. SEM Imaging – Using the same protocol as above, after the 48-hour incubation period, an n = 7 of each material type were fixed in 2.5% glutaraldehyde, dehydrated in ascending concentrations of ethanol, coated with carbon and imaged using scanning electron microscopy (SEM). Results:. Results indicated that the Vitamin E blended materials did not resist the attachment/formation of MRSA biofilms to any greater degree than the other three material types. All materials had greater than 10. 7. CFU/cm. 2. (Figure 1). SEM images corroborated with the quantification data (Figure 2). Discussion:. In contrast to previously published results,. 1–3. these data indicated that Vitamin E blended UHMWPE may not have the ability to prevent biofilm formation of a clinical MRSA isolate from occurring


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 42 - 42
1 Mar 2017
Tamaki S Tonai T Kimura T Sasa T Inoue T
Full Access

Objective. Bacterial infection is a serious complication after joint replacement surgery. In particular, methicillin-resistant Staphylococcus aureus (MRSA) and epidermidis(MRSE) are very difficult to eradicate in infected prosthetic joint. Therefore, the retention rate of initial prosthesis affected with such resistant microorganisms is still low. Gentian violet shows potent antibacterial activity against gram-positive cocci as minimal bactericidal concentration is less than 0.1 %. In the present study, we investigated the efficacy of treatment with gentian violet against MRSA and MRSE infections after THA, TKA, and bipolar hip hemiarthroplasty (BHP). Methods. There were 8 patients in this study; five patients with deep periprosthetic MRSA infection (2 THA, 2 BHP, 1 revision TKA); 3 patients with MRSE infection (1 revision THA, 1 BHP, 1 TKA). When infection was suspected after the surgery, we quickly obtained synovial fluid and periprosthetic soft tissue from the joint and applied to culture and microscopic examinations for detection of microorganisms. After identification of bacterial species, we immediately debrided the affected joint and washed thoroughly twice with 0.1% solution of gentian violet for 3 minutes each, followed by intra-articular multiple injection of arbekacin sulfate solution. Then we inserted an aspiration tube into the joint and administered appropriate antibiotics intravenously. If the inflammatory symptoms persisted in spite of the first treatment, we repeated the treatment until inflammation signs and intra-articular microorganisms could not be detected. Results. At first we examined the bactericidal activity of gentian violet solution against MRSA and MRSE by culture examination with or without the solution. We confirmed gram-negative bacillicould be alive but the both MRSA and MRSE could not be alive by the treatment with 0.01 % solution of gentian violet for 3 minutes. The treatment with gentian violet allowed subsidence of the infection in all patients. Furthermore, we could preserve 4 prostheses with MRSA infection; 1 THA, 1 revision TKA and 2 BHPs; 2 prostheses with MRSE infection; 1 TKA, 1BHP. However, we could not preserve 2 prostheses, 1 THA with MRSA infection and 1 revision THA with MRSE infection. Thus, the prosthetic retention rate of this study for MRSA and MRSE infections was 75 %. We performed two-stage operation for the 2 patients in whom we could not preserve the prostheses as follows: after excision of the infected total hips followed by successful reimplantation. Moreover, all of the patients in this study are able to keep the walking ability after joint replacements. Conclusion. Infection of methicillin-resistant Staphylococcus species after joint replacement surgery has tended to increase. Gentian violet exerts a potent antibacterial activity against such microorganisms at the concentration of less than 0.1 %. We obtained good retention rate by the treatment using gentian violet against MRSA and MRSE infections after the joint surgeries. In addition, both MRSA and MRSE have not showed drug resistance for gentian violet. Therefore, we suggest that gentian violet will become a promising adjunct agent for infection after joint replacement surgery not only methicillin-sensitive but also methicillin–resistant Staphylococcus species


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 32 - 33
1 Mar 2010
Richmond JC Spencer M Davidson SM
Full Access

Purpose: Asymptomatic colonization with methicillin-resistant Staphylococcus aureus (MRSA) and Methicillin-sensitive Staph. aureus (MSSA) has been described as a risk factor for subsequent surgical site infection. Colonization of nares, either present at admission to the hospital or acquired during hospitalization, increases the risk for infection. Identifying Staph. aureus colonization in the presurgical screening process is important in reducing subsequent surgical site infection. We performed anterior nares surveillance screens of 6551 inpatient surgeries using polymerase chain reaction (PCR) assay. This rapid technology provided results in less than 24 hrs and a decolonization protocol was administered. Method: Patients admitted for orthopedic surgery were screened in the prescreening unit. The treatment intervention for MRSA and MSSA patients was 5-day application of intranasal mupirocin 2% applied twice daily. In addition, MRSA positive patients were instructed to bathe with chlorhexidine 2% for 5 days and were rescreened prior to surgery. Contact precautions were implemented if the second screen was positive for MRSA. All MRSA positives received vancomycin for surgical prophylaxis. Results: From July 17, 2006 through August 31, 2007, 6551 patients were screened; 1471 (22%) were MSSA positive and 291 (4%) were MRSA positive. Repeat nasal screens were obtained from MRSA patients prior to surgery and revealed 86% eradication. In the cohort of positive screens, there were 3 MSSA infections (0.2%) and 3 MRSA infections (1.0%). In the 4789 negative screens there were 7 infections (1 MRSA and 6 MSSA). The surgical site infection rate in the screened patients was 0.2%. In an equivalent group of unscreened patients from the prior year, the infection rate had been 0.4%. Conclusion: We have successfully implemented an MRSA and MSSA eradication program for all inpatient surgeries during the prescreening process. It has allowed for early identification of patients colonized with MRSA and MSSA, decolonization treatment, and appropriate surgical prophylaxis for MRSA. Since implementation we have documented a significant reduction in infection rates due to MRSA and MSSA. A multidisciplinary approach with strong administrative support and consistent communication was vital to the implementation of the program


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 93 - 94
1 Mar 2010
Noda I Ando Y Miyamoto H Shimazaki T Yonekura Y Miyazaki M Mawatari M Hotokebuchi T
Full Access

Bacterial infection related to orthopaedic implants is a significant complication today. One of the ways to reduce the incidence of implant-associated infections is assumed to give antibacterial activity to surface of implant itself. We focused attention on Ag, because it has a broad antibacterial spectrum, strong antimicrobial activity and low toxicity. In the previous works, sputtering, electrochemically deposition and sol-gel coating of Ag-containing hydroxyapatite (HA) have been reported. However, since practical technique of HA coating widely used for medical and dental implants has been the “thermal spraying” technique over the last two decades, we aimed at developing the novel thermal spraying technology for Ag-HA coating with antibacterial activity. In this study, physical and chemical properties, in vitro antibacterial activity, inhibition activity of bacterial attachment, HA-forming ability, cytotoxicity and release of Ag ions of the thermal-sprayed Ag-HA coating were evaluated. HA powder containing 3wt % of silver oxide (Ag2O) was sprayed on surface of titanium disks by the thermal spraying method using acetylene torch. SEM images showed a typical structure of the thermal-sprayed coating and the X-ray diffraction (XRD) pattern of the coating showed an amorphous structure. Ag residue in the coating was determined by the elementary analysis. The coating showed strong antibacterial activity and inhabitation activity of bacterial attachment to the methicillin-resistant Staphylococcus aureus (MRSA) in fetal bovine serum (FBS). On the other hand, the coating showed fast HA-forming ability in simulated body fluid (SBF) and no cytotoxicity related to Ag contained in the coating. Therefore, it is expected that the thermal-sprayed Ag-HA coating provides antibacterial and bone-bonding ability on the surface of the implant itself. In addition, though the HA coating is generally liable to adhere bacteria, the thermal-sprayed Ag-HA coating overcomes this problem. Pre-evaluation of release of Ag ions from the Ag-containing ceramic powders indicated that the releasing behavior of Ag ions in SBFs is dependent on the existing form of Ag in the Ag-containing material. It is assumed that most of Ag components in the Ag-HA coating are not retained as metallic Ag but as Ag2O in the amorphous layer. Time-course release tests of Ag ions from the coating in FBS showed a large release rate of Ag ions until 24 h after the immersion. It is expected that the Ag-HA coating could show strong antibacterial activity at the early post-operative stage. In the repeated release testing, the amount of released Ag ions was about 6500 ppb for the first release test, after which it gradually decreased. However, a significant release amount of Ag ions was observed even after the sixth repeat test. Therefore, it was assumed that the thermal-sprayed Ag-HA coating has a slow-release property of Ag ions in FBS


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 328 - 328
1 Mar 2013
Shimizu T Kato M Ono Y Yasura K Aoto T Hirakawa A Matsuo H Kyo M
Full Access

Purpose. Surgical site infection (SSI) is an infrequent but serious complication of total joint arthroplasty (TJA). Orthopaedic SSI causes substantial morbidity, prolonging the hospital stay by a median of 2 weeks, doubling the rates of rehospitalization, and more than tripling overall healthcare costs. Colonization with methicillin-resistant Staphylococcus aureus (MRSA) and methicillin-sensitive S. aureus (MSSA) is known to be associated with an increased risk of subsequent SSI. Carriers are two to nine times more likely to acquire S. aureus SSIs than non-carriers. Screening of the nose and throat for MRSA colonization and preoperative patient decolonization have been shown to decrease the incidence of subsequent MRSA infection. The aim of this study was to investigate the association between the results of MRSA colonization screening and the incidence of SSI in our hospital. Materials and Methods. Between June 2007 and June 2010, 238 patients were admitted for TJA, among whom 235 underwent preoperative assessment that included screening of the nose and throat for MRSA colonization. Fifty-nine of these patients underwent total hip arthroplasty (THA), 69 underwent total knee arthroplasty (TKA), 6 underwent unilateral knee arthroplasty (UKA), and 101 underwent bipolar hip prosthesis arthroplasty (BPH). The mean age of the patients was 72.7 (49–95) years and the male to female ratio was 1:3.8. We analyzed these patients retrospectively, and determined the site of colonization, eradication prior to surgery, and subsequent development of SSI in the year after surgery. SSI was defined according to the criteria established by the Centers for Disease Control and Prevention. Results. MRSA colonization was positive in 12 patients (5.1%) at the initial preoperative assessment (Fig. 1). All except 2 of the positive patients underwent nasal eradication with mupirocin 2% three times daily for three days. Eight of 10 patients were confirmed to be MRSA-negative after re-swabbing. During surgery, all patients received perioperative antibiotic prophylaxis. The standard regimen was cefazolin 1 g administered 15 to 30 min before incision, followed by 1 g every 3 hours until skin closure. One hundred eighty-six patients were monitored for development of SSIs for 1 year after TJA. Among these patients, 1 in the MRSA-positive group and 1 in the negative group developed MRSA SSIs (P<0.01)(Fig. 2). Discussion. Bode et al. recently reported that rapid screening and decolonizing of nasal S. aureus carriers with intranasal mupirocin prevented SSIs after mixed surgery. However, several studies of the effect of screening and decolonization for such carriers have yielded paradoxical findings because of differences in study design or sample size. Conclusion. We conclude that MRSA-colonized patients undergoing TJA are at an increased risk of SSI, despite eradication therapy prior to surgery. Use of prophylactic antibiotics such as vancomycin or teicoplanin may be beneficial


Bone & Joint 360
Vol. 12, Issue 3 | Pages 40 - 41
1 Jun 2023

The June 2023 Research Roundup360 looks at: Characterizing recurrent infections after one-stage revision for periprosthetic joint infection of the knee; Predicted waiting times for orthopaedic surgery: an urgent need to address the deficit in capacity; Vascular impulse technology versus elevation for reducing the swelling of upper and lower limb joint fractures; Desperate patients will accept higher risks; How long does it take to find a positive culture in periprosthetic joint infection?


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 833 - 836
1 Aug 2023
Mancino F Gant V Meek DRM Haddad FS


Bone & Joint Open
Vol. 2, Issue 11 | Pages 958 - 965
16 Nov 2021
Craxford S Marson BA Nightingale J Ikram A Agrawal Y Deakin D Ollivere B

Aims

Deep surgical site infection (SSI) remains an unsolved problem after hip fracture. Debridement, antibiotic, and implant retention (DAIR) has become a mainstream treatment in elective periprosthetic joint infection; however, evidence for DAIR after infected hip hemiarthroplaty is limited.

Methods

Patients who underwent a hemiarthroplasty between March 2007 and August 2018 were reviewed. Multivariable binary logistic regression was performed to identify and adjust for risk factors for SSI, and to identify factors predicting a successful DAIR at one year.


Aims

Achievement of accurate microbiological diagnosis prior to revision is key to reducing the high rates of persistent infection after revision knee surgery. The effect of change in the microorganism between the first- and second-stage revision of total knee arthroplasty for periprosthetic joint infection (PJI) on the success of management is not clear.

Methods

A two-centre retrospective cohort study was conducted to review the outcome of patients who have undergone two-stage revision for treatment of knee arthroplasty PJI, focusing specifically on isolated micro-organisms at both the first- and second-stage procedure. Patient demographics, medical, and orthopaedic history data, including postoperative outcomes and subsequent treatment, were obtained from the electronic records and medical notes.


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 815 - 820
1 Jul 2023
Mitchell PD Abraham A Carpenter C Henman PD Mavrotas J McCaul J Sanghrajka A Theologis T

Aims

The aim of this study was to determine the consensus best practice approach for the investigation and management of children (aged 0 to 15 years) in the UK with musculoskeletal infection (including septic arthritis, osteomyelitis, pyomyositis, tenosynovitis, fasciitis, and discitis). This consensus can then be used to ensure consistent, safe care for children in UK hospitals and those elsewhere with similar healthcare systems.

Methods

A Delphi approach was used to determine consensus in three core aspects of care: 1) assessment, investigation, and diagnosis; 2) treatment; and 3) service, pathways, and networks. A steering group of paediatric orthopaedic surgeons created statements which were then evaluated through a two-round Delphi survey sent to all members of the British Society for Children’s Orthopaedic Surgery (BSCOS). Statements were only included (‘consensus in’) in the final agreed consensus if at least 75% of respondents scored the statement as critical for inclusion. Statements were discarded (‘consensus out’) if at least 75% of respondents scored them as not important for inclusion. Reporting these results followed the Appraisal Guidelines for Research and Evaluation.


Bone & Joint 360
Vol. 12, Issue 4 | Pages 13 - 16
1 Aug 2023

The August 2023 Hip & Pelvis Roundup360 looks at: Using machine learning to predict venous thromboembolism and major bleeding events following total joint arthroplasty; Antibiotic length in revision total hip arthroplasty; Preoperative colonization and worse outcomes; Short stem cemented total hip arthroplasty; What are the outcomes of one- versus two-stage revisions in the UK?; To cement or not to cement? The best approach in hemiarthroplasty; Similar re-revisions in cemented and cementless femoral revisions for periprosthetic femoral fractures in total hip arthroplasty; Are hip precautions still needed?


Objectives

Irrigation is the cornerstone of treating skeletal infection by eliminating pathogens in wounds. A previous study shows that irrigation with normal saline (0.9%) and ethylenediaminetetraacetic acid (EDTA) could improve the removal of Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) compared with normal saline (NS) alone. However, it is still unclear whether EDTA solution is effective against infection with drug-resistant bacteria.

Methods

We established three wound infection models (skin defect, bone-exposed, implant-exposed) by inoculating the wounds with a variety of representative drug-resistant bacteria including methicillin-resistant S. aureus (MRSA), extended spectrum beta-lactamase-producing E. coli (ESBL-EC), multidrug-resistant Pseudomonas aeruginosa (MRPA), vancomycin-resistant Enterococcus (VRE), multidrug-resistant Acinetobacter baumannii (MRAB), multidrug-resistant Enterobacter (MRE), and multidrug-resistant Proteus mirabilis (MRPM). Irrigation and debridement were repeated until the wound culture became negative. The operating times required to eliminate pathogens in wounds were compared through survival analysis.


Bone & Joint 360
Vol. 13, Issue 4 | Pages 19 - 23
2 Aug 2024

The August 2024 Foot & Ankle Roundup360 looks at: ESWT versus surgery for fifth metatarsal stress fractures; Minimally invasive surgery versus open fusion for hallux rigidus; Diabetes and infection risk in total ankle arthroplasty; Is proximal medial gastrocnemius recession useful for managing chronic plantar fasciitis?; Fuse the great toe in the young!; Conservative surgery for diabetic foot osteomyelitis; Mental health and outcome following foot and ankle surgery.


Bone & Joint Research
Vol. 13, Issue 7 | Pages 332 - 341
5 Jul 2024
Wang T Yang C Li G Wang Y Ji B Chen Y Zhou H Cao L

Aims

Although low-intensity pulsed ultrasound (LIPUS) combined with disinfectants has been shown to effectively eliminate portions of biofilm in vitro, its efficacy in vivo remains uncertain. Our objective was to assess the antibiofilm potential and safety of LIPUS combined with 0.35% povidone-iodine (PI) in a rat debridement, antibiotics, and implant retention (DAIR) model of periprosthetic joint infection (PJI).

Methods

A total of 56 male Sprague-Dawley rats were established in acute PJI models by intra-articular injection of bacteria. The rats were divided into four groups: a Control group, a 0.35% PI group, a LIPUS and saline group, and a LIPUS and 0.35% PI group. All rats underwent DAIR, except for Control, which underwent a sham procedure. General status, serum biochemical markers, weightbearing analysis, radiographs, micro-CT analysis, scanning electron microscopy of the prostheses, microbiological analysis, macroscope, and histopathology evaluation were performed 14 days after DAIR.


Bone & Joint Open
Vol. 3, Issue 6 | Pages 485 - 494
13 Jun 2022
Jaubert M Le Baron M Jacquet C Couvreur A Fabre-Aubrespy M Flecher X Ollivier M Argenson J

Aims

Two-stage exchange revision total hip arthroplasty (THA) performed in case of periprosthetic joint infection (PJI) has been considered for many years as being the gold standard for the treatment of chronic infection. However, over the past decade, there have been concerns about its safety and its effectiveness. The purposes of our study were to investigate our practice, collecting the overall spacer complications, and then to analyze their risk factors.

Methods

We retrospectively included 125 patients with chronic hip PJI who underwent a staged THA revision performed between January 2013 and December 2019. All spacer complications were systematically collected, and risk factors were analyzed. Statistical evaluations were performed using the Student's t-test, Mann-Whitney U test, and Fisher's exact test.


Bone & Joint Open
Vol. 3, Issue 1 | Pages 35 - 41
9 Jan 2022
Buchalter DB Nduaguba A Teo GM Kugelman D Aggarwal VK Long WJ

Aims

Despite recent literature questioning their use, vancomycin and clindamycin often substitute cefazolin as the preoperative antibiotic prophylaxis in primary total knee arthroplasty (TKA), especially in the setting of documented allergy to penicillin. Topical povidone-iodine lavage and vancomycin powder (VIP) are adjuncts that may further broaden antimicrobial coverage, and have shown some promise in recent investigations. The purpose of this study, therefore, is to compare the risk of acute periprosthetic joint infection (PJI) in primary TKA patients who received cefazolin and VIP to those who received a non-cephalosporin alternative and VIP.

Methods

This was a retrospective cohort study of 11,550 primary TKAs performed at an orthopaedic hospital between 2013 and 2019. The primary outcome was PJI occurring within 90 days of surgery. Patients were stratified into two groups (cefazolin vs non-cephalosporin) based on their preoperative antibiotic. All patients also received the VIP protocol at wound closure. Bivariate and multiple logistic regression analyses were performed to control for potential confounders and identify the odds ratio of PJI.


Bone & Joint Research
Vol. 10, Issue 12 | Pages 790 - 796
1 Dec 2021
Fang X Wang Q Yang X Zhang F Huang C Huang Z Shen H Zhang W

Aims

To explore the effect of different durations of antibiotics after stage II reimplantation on the prognosis of two-stage revision for chronic periprosthetic joint infection (PJI).

Methods

This study involved a retrospective collection of patients who underwent two-stage revision for chronic PJI and continued to use extended antibiotic prophylaxis in two regional medical centres from January 2010 to June 2018. The patients were divided into a short (≤ one month) or a long (> one month) course of treatment based on the duration of antibiotics following stage II reimplantation. The difference in the infection control rate between the two groups was compared, and prognostic factors for recurrence were analyzed.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1611 - 1618
1 Oct 2021
Kavarthapu V Budair B

Aims

In our unit, we adopt a two-stage surgical reconstruction approach using internal fixation for the management of infected Charcot foot deformity. We evaluate our experience with this functional limb salvage method.

Methods

We conducted a retrospective analysis of prospectively collected data of all patients with infected Charcot foot deformity who underwent two-stage reconstruction with internal fixation between July 2011 and November 2019, with a minimum of 12 months’ follow-up.


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1678 - 1685
1 Nov 2021
Abdelaziz H Schröder M Shum Tien C Ibrahim K Gehrke T Salber J Citak M

Aims

One-stage revision hip arthroplasty for periprosthetic joint infection (PJI) has several advantages; however, resection of the proximal femur might be necessary to achieve higher success rates. We investigated the risk factors for resection and re-revisions, and assessed complications and subsequent re-revisions.

Methods

In this single-centre, case-control study, 57 patients who underwent one-stage revision arthroplasty for PJI of the hip and required resection of the proximal femur between 2009 and 2018 were identified. The control group consisted of 57 patients undergoing one-stage revision without bony resection. Logistic regression analysis was performed to identify any correlation with resection and the risk factors for re-revisions. Rates of all-causes re-revision, reinfection, and instability were compared between groups.


Bone & Joint 360
Vol. 10, Issue 3 | Pages 26 - 29
1 Jun 2021


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 191 - 195
1 Jun 2021
Gausden EB Shirley MB Abdel MP Sierra RJ

Aims

To describe the risk of periprosthetic joint infection (PJI) and reoperation in patients who have an acute, traumatic wound dehiscence following total knee arthroplasty (TKA).

Methods

From January 2002 to December 2018, 16,134 primary TKAs were performed at a single institution. A total of 26 patients (0.1%) had a traumatic wound dehiscence within the first 30 days. Mean age was 68 years (44 to 87), 38% (n = 10) were female, and mean BMI was 34 kg/m2 (23 to 48). Median time to dehiscence was 13 days (interquartile range (IQR) 4 to 15). The dehiscence resulted from a fall in 22 patients and sudden flexion after staple removal in four. The arthrotomy was also disrupted in 58% (n = 15), including a complete extensor mechanism disruption in four knees. An irrigation and debridement with component retention (IDCR) was performed within 48 hours in 19 of 26 knees and two-thirds were discharged on antibiotic therapy. The mean follow-up was six years (2 to 15). The association of wound dehiscence and the risk of developing a PJI was analyzed.


Bone & Joint Research
Vol. 9, Issue 12 | Pages 870 - 872
21 Dec 2020
Tsang SJ Simpson AHRW


Bone & Joint 360
Vol. 10, Issue 2 | Pages 43 - 47
1 Apr 2021


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 522 - 529
1 Mar 2021
Nichol T Callaghan J Townsend R Stockley I Hatton PV Le Maitre C Smith TJ Akid R

Aims

The aim of this study was to develop a single-layer hybrid organic-inorganic sol-gel coating that is capable of a controlled antibiotic release for cementless hydroxyapatite (HA)-coated titanium orthopaedic prostheses.

Methods

Coatings containing gentamicin at a concentration of 1.25% weight/volume (wt/vol), similar to that found in commercially available antibiotic-loaded bone cement, were prepared and tested in the laboratory for: kinetics of antibiotic release; activity against planktonic and biofilm bacterial cultures; biocompatibility with cultured mammalian cells; and physical bonding to the material (n = 3 in all tests). The sol-gel coatings and controls were then tested in vivo in a small animal healing model (four materials tested; n = 6 per material), and applied to the surface of commercially pure HA-coated titanium rods.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 916 - 922
1 May 2021
Qiao J Xu C Chai W Hao L Zhou Y Fu J Chen J

Aims

It can be extremely challenging to determine whether to perform reimplantation in patients who have contradictory serum inflammatory markers and frozen section results. We investigated whether patients with a positive frozen section at reimplantation were at a higher risk of reinfection despite normal ESR and CRP.

Methods

We retrospectively reviewed 163 consecutive patients with periprosthetic joint infections (PJIs) who had normal ESR and CRP results pre-reimplantation in our hospital from 2014 to 2018. Of these patients, 26 had positive frozen sections at reimplantation. The minimum follow-up time was two years unless reinfection occurred within this period. Univariable and multivariable logistic regression analyses were performed to identify the association between positive frozen sections and treatment failure.


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 456 - 461
1 Mar 2021
Sasaki G Watanabe Y Yasui Y Nishizawa M Saka N Kawano H Miyamoto W

Aims

To clarify the effectiveness of the induced membrane technique (IMT) using beta-tricalcium phosphate (β-TCP) for reconstruction of segmental bone defects by evaluating clinical and radiological outcomes, and the effect of defect size and operated site on surgical outcomes.

Methods

A review of the medical records was conducted of consecutive 35 lower limbs (30 males and five females; median age 46 years (interquartile range (IQR) 40 to 61)) treated with IMT using β-TCP between 2014 and 2018. Lower Extremity Functional Score (LEFS) was examined preoperatively and at final follow-up to clarify patient-centered outcomes. Bone healing was assessed radiologically, and time from the second stage to bone healing was also evaluated. Patients were divided into ≥ 50 mm and < 50 mm defect groups and into femoral reconstruction, tibial reconstruction, and ankle arthrodesis groups.


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 9 - 15
1 Jun 2019
Wyles CC Hevesi M Osmon DR Park MA Habermann EB Lewallen DG Berry DJ Sierra RJ

Aims

The aims of this study were to characterize antibiotic choices for perioperative total knee arthroplasty (TKA) and total hip arthroplasty (THA) prophylaxis, assess antibiotic allergy testing efficacy, and determine rates of prosthetic joint infection (PJI) based on perioperative antibiotic regimen.

Patients and Methods

We evaluated all patients undergoing primary TKA or THA at a single academic institution between January 2004 and May 2017, yielding 29 695 arthroplasties (22 705 patients), with 3411 arthroplasties in 2576 patients (11.5%) having undergone preoperative allergy testing. A series of institutional databases were combined to identify allergy consultation outcomes, perioperative antibiotic regimen, and infection-free survivorship until final follow-up.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 158 - 162
1 Jun 2020
Griseti Q Jacquet C Sautet P Abdel MP Parratte S Ollivier M Argenson J

Aims

The aim of this study was to compare the ability of tantalum, 3D porous titanium, antibiotic-loaded bone cement, and smooth titanium alloy to inhibit staphylococci in an in vitro environment, based on the evaluation of the zone of inhibition (ZOI). The hypothesis was that there would be no significant difference in the inhibition of methicillin-sensitive or methicillin-resistant Staphylococcus aureus (MSSA/MRSA) between the two groups.

Methods

A total of 30 beads made of three different materials (tantalum/3D porous titanium and smooth titanium alloy) were bathed for one hour in a solution of 1 g vancomycin in 20 ml of sterile water for injection (bath concentration: 50 mg/mL). Ten 1 cm3 cylinders of antibiotic-loaded cement were also created by mixing standard surgical cement with 1 g of vancomycin in standardized sterile moulds. The cylinders were then placed on agar plates inoculated with MSSA and MRSA. The ZOIs were measured each day and the cylinders were transferred onto a new inoculated plate.


Bone & Joint Research
Vol. 9, Issue 8 | Pages 450 - 456
1 Aug 2020
Zhang Z Cai Y Bai G Zhang C Li W Yang B Zhang W

Aims

This study aimed to evaluate calprotectin in synovial fluid for diagnosing chronic prosthetic joint infection (PJI) .

Methods

A total of 63 patients who were suspected of PJI were enrolled. The synovial fluid calprotectin was tested by an enzyme-linked immunosorbent assay (ELISA). Laboratory test data, such as ESR, CRP, synovial fluid white blood cells (SF-WBCs), and synovial fluid polymorphonuclear cells (SF-PMNs), were documented. Chi-squared tests were used to compare the sensitivity and specificity of calprotectin and laboratory tests. The area under the curve (AUC) of the receiver operating characteristic (ROC) curve was calculated to determine diagnostic efficacy.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 176 - 180
1 Jun 2020
Lee G Colen DL Levin LS Kovach SJ

Aims

The integrity of the soft tissue envelope is crucial for successful treatment of infected total knee arthroplasty (TKA). The purpose of this study was to evaluate the rate of limb salvage, infection control, and clinical function following microvascular free flap coverage for salvage of the infected TKA.

Methods

We retrospectively reviewed 23 microvascular free tissue transfers for management of soft tissue defects in infected TKA. There were 16 men and seven women with a mean age of 61.2 years (39 to 81). The median number of procedures performed prior to soft tissue coverage was five (2 to 9) and all patients had failed at least one two-stage reimplantation procedure. Clinical outcomes were measured using the Knee Society Scoring system for pain and function.


Bone & Joint Research
Vol. 9, Issue 11 | Pages 778 - 788
1 Nov 2020
Xu H Yang J Xie J Huang Z Huang Q Cao G Pei F

Aims

The efficacy and safety of intrawound vancomycin for preventing surgical site infection in primary hip and knee arthroplasty is uncertain.

Methods

A systematic review of the literature was conducted, indexed from inception to March 2020 in PubMed, Web of Science, Cochrane Library, Embase, and Google Scholar databases. All studies evaluating the efficacy and/or safety of intrawound vancomycin in patients who underwent primary hip and knee arthroplasty were included. Incidence of periprosthetic joint infection (PJI), superficial infection, aseptic wound complications, acute kidney injury, anaphylactic reaction, and ototoxicity were meta-analyzed. Results were reported as odds ratios (ORs) and 95% confidence intervals (CIs). The quality of included studies was assessed using the risk of bias in non-randomized studies of interventions (ROBINS-I) assessment tool.


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 3 - 10
1 Jul 2020
Sosa BR Niu Y Turajane K Staats K Suhardi V Carli A Fischetti V Bostrom M Yang X

Aims

Current treatments of prosthetic joint infection (PJI) are minimally effective against Staphylococcus aureus biofilm. A murine PJI model of debridement, antibiotics, and implant retention (DAIR) was used to test the hypothesis that PlySs2, a bacteriophage-derived lysin, can target S. aureus biofilm and address the unique challenges presented in this periprosthetic environment.

Methods

The ability of PlySs2 and vancomycin to kill biofilm and colony-forming units (CFUs) on orthopaedic implants were compared using in vitro models. An in vivo murine PJI model of DAIR was used to assess the efficacy of a combination of PlySs2 and vancomycin on periprosthetic bacterial load.


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 11 - 19
1 Jul 2020
Shohat N Goswami K Tan TL Yayac M Soriano A Sousa R Wouthuyzen-Bakker M Parvizi J

Aims

Failure of irrigation and debridement (I&D) for prosthetic joint infection (PJI) is influenced by numerous host, surgical, and pathogen-related factors. We aimed to develop and validate a practical, easy-to-use tool based on machine learning that may accurately predict outcome following I&D surgery taking into account the influence of numerous factors.

Methods

This was an international, multicentre retrospective study of 1,174 revision total hip (THA) and knee arthroplasties (TKA) undergoing I&D for PJI between January 2005 and December 2017. PJI was defined using the Musculoskeletal Infection Society (MSIS) criteria. A total of 52 variables including demographics, comorbidities, and clinical and laboratory findings were evaluated using random forest machine learning analysis. The algorithm was then verified through cross-validation.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 336 - 344
1 Mar 2020
Ji B Li G Zhang X Wang Y Mu W Cao L

Aims

In the absence of an identified organism, single-stage revision is contraindicated in prosthetic joint infection (PJI). However, no studies have examined the use of intra-articular antibiotics in combination with single-stage revision in these cases. In this study, we present the results of single-stage revision using intra-articular antibiotic infusion for treating culture-negative (CN) PJI.

Methods

A retrospective analysis between 2009 and 2016 included 51 patients with CN PJI who underwent single-stage revision using intra-articular antibiotic infusion; these were compared with 192 culture-positive (CP) patients. CN patients were treated according to a protocol including intravenous vancomycin and a direct intra-articular infusion of imipenem and vancomycin alternately used in the morning and afternoon. In the CP patients, pathogen-sensitive intravenous (IV) antibiotics were administered for a mean of 16 days (12 to 21), and for resistant cases, additional intra-articular antibiotics were used. The infection healing rate, Harris Hip Score (HHS), and Hospital for Special Surgery (HSS) knee score were compared between CN and CP groups.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 848 - 851
1 Jul 2019
Sautet P Parratte S Mékidèche T Abdel MP Flécher X Argenson J Ollivier M

Aims

The aims of this study were to compare the mean duration of antibiotic release and the mean zone of inhibition between vancomycin-loaded porous tantalum cylinders and antibiotic-loaded bone cement at intervals, and to evaluate potential intrinsic antimicrobial properties of tantalum in an in vitro medium environment against methicillin-sensitive Staphylococcus aureus (MSSA).

Materials and Methods

Ten porous tantalum cylinders and ten cylinders of cement were used. The tantalum cylinders were impregnated with vancomycin, which was also added during preparation of the cylinders of cement. The cylinders were then placed on agar plates inoculated with MSSA. The diameter of the inhibition zone was measured each day, and the cylinders were transferred to a new inoculated plate. Inhibition zones were measured with a Vernier caliper and using an automated computed evaluation, and the intra- and interobserver reproducibility were measured. The mean inhibition zones between the two groups were compared with Wilcoxon’s test.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 292 - 298
1 Mar 2008
Walls RJ Roche SJ O’Rourke A McCabe JP

We have analysed the management and clinical outcome of a series of consecutive patients who had a total hip replacement and developed post-operative surgical site infection (SSI) with methicillin-resistant Staphylococcus aureus. The incidence of this infection was 1% over a period of five years. We studied SSI in 15 patients (16 infections) with a mean age of 72.7 years (53 to 81). In all, 12 of the infections occurred early and half of the infections involved the prosthesis, resulting in an increase of 11-fold in the cumulative hospital stay.

Methicillin-resistant Staph. aureus was successfully eradicated in all the patients after a mean follow-up of 53.6 months (25 to 88). Superficial incisional infections resolved after antibiotic therapy alone while deep infections required multiple operative debridements. Attempted retention of the implant in early organ space infections was successful in only one of five patients. Only three patients with implant-level infections obtained a pain-free, functional prosthesis while a further three required excision arthroplasty. We have formulated a protocol of treatment which may serve as a guide in the management of these infections.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 582 - 588
1 May 2019
Sidhu MS Cooper G Jenkins N Jeys L Parry M Stevenson JD

Aims

The aims of this study were to report the efficacy of revision surgery for patients with co-infective bacterial and fungal prosthetic joint infections (PJIs) presenting to a single institution, and to identify prognostic factors that would guide management.

Patients and Methods

A total of 1189 patients with a PJI were managed in our bone infection service between 2006 and 2015; 22 (1.85%) with co-infective bacterial and fungal PJI were included in the study. There were nine women and 13 men, with a mean age at the time of diagnosis of 64.5 years (47 to 83). Their mean BMI was 30.9 kg/m2 (24 to 42). We retrospectively reviewed the outcomes of these PJIs, after eight total hip arthroplasties and 14 total knee arthroplasties. The mean clinical follow-up was 4.1 years (1.4 to 8.8).


Bone & Joint Research
Vol. 8, Issue 2 | Pages 49 - 54
1 Feb 2019
Stravinskas M Nilsson M Vitkauskiene A Tarasevicius S Lidgren L

Objectives

The aim of this study was to analyze drain fluid, blood, and urine simultaneously to follow the long-term release of vancomycin from a biphasic ceramic carrier in major hip surgery. Our hypothesis was that there would be high local vancomycin concentrations during the first week with safe low systemic trough levels and a complete antibiotic release during the first month.

Methods

Nine patients (six female, three male; mean age 75.3 years (sd 12.3; 44 to 84)) with trochanteric hip fractures had internal fixations. An injectable ceramic bone substitute, with hydroxyapatite in a calcium sulphate matrix, containing 66 mg of vancomycin per millilitre, was inserted to augment the fixation. The vancomycin elution was followed by simultaneously collecting drain fluid, blood, and urine.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 91 - 97
1 Jul 2019
Chalmers BP Weston JT Osmon DR Hanssen AD Berry DJ Abdel MP

Aims

There is little information regarding the risk of a patient developing prosthetic joint infection (PJI) after primary total knee arthroplasty (TKA) when the patient has previously experienced PJI of a TKA or total hip arthroplasty (THA) in another joint. The goal of this study was to compare the risk of PJI of primary TKA in this patient population against matched controls.

Patients and Methods

We retrospectively reviewed 95 patients (102 primary TKAs) treated between 2000 and 2014 with a history of PJI in another TKA or THA. A total of 50 patients (53%) were female. Mean age was 69 years (45 to 88) with a mean body mass index (BMI) of 36 kg/m2 (22 to 59). In total, 27% of patients were on chronic antibiotic suppression. Mean follow-up was six years (2 to 16). We 1:3 matched these (for age, sex, BMI, and surgical year) to 306 primary TKAs performed in 306 patients with a THA or TKA of another joint without a subsequent PJI. Competing risk with death was used for statistical analysis. Multivariate analysis was followed to evaluate risk factors for PJI in the study cohort.


Bone & Joint 360
Vol. 8, Issue 2 | Pages 12 - 15
1 Apr 2019


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 221 - 226
1 Feb 2019
Ryan SP DiLallo M Klement MR Luzzi AJ Chen AF Seyler TM

Aims

The aim of this study was to characterize the factors leading to transfemoral amputation after total knee arthroplasty (TKA), as well as the rates of mortality and functional independence after this procedure in these patients.

Patients and Methods

This was a multicentre retrospective review with a prospective telephone survey for the assessment of function. All patients with a TKA who subsequently required transfemoral amputation between January 2001 and December 2015 were included. Demographic information, medical comorbidities, and postoperative mortality data were collected. A 19-item survey was used for the assessment of function in surviving patients.


Bone & Joint Research
Vol. 8, Issue 8 | Pages 387 - 396
1 Aug 2019
Alt V Rupp M Lemberger K Bechert T Konradt T Steinrücke P Schnettler R Söder S Ascherl R

Objectives

Preclinical data showed poly(methyl methacrylate) (PMMA) loaded with microsilver to be effective against a variety of bacteria. The purpose of this study was to assess patient safety of PMMA spacers with microsilver in prosthetic hip infections in a prospective cohort study.

Methods

A total of 12 patients with prosthetic hip infections were included for a three-stage revision procedure. All patients received either a gentamicin-PMMA spacer (80 g to 160 g PMMA depending on hip joint dimension) with additional loading of 1% (w/w) of microsilver (0.8 g to 1.6 g per spacer) at surgery 1 followed by a gentamicin-PMMA spacer without microsilver at surgery 2 or vice versa. Implantation of the revision prosthesis was carried out at surgery 3.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 249 - 252
1 Feb 2009
Fascia DTM Singanayagam A Keating JF

We have conducted a case-control study over a period of ten years comparing both deep infection with methicillin-resistant staphylococcus aureus (MRSA) and colonised cases with a control group.

Risk factors associated with deep infection were vascular diseases, chronic obstructive pulmonary disease, admission to a high-dependency or an intensive-care unit and open wounds. Those for colonisation were institutional care, vascular diseases and dementia. Older age was a risk factor for any MRSA infection. The length of hospital stay was dramatically increased by deep infection.

These risk factors are useful in identifying higher-risk patients who may be more susceptible to MRSA infection. A strategy of early identification and isolation may help to control its spread in trauma units.


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 396 - 402
1 Apr 2019
Ji B Wahafu T Li G Zhang X Wang Y Momin M Cao L

Aims

Single-stage revision is not widely pursued due to restrictive inclusion criteria. In this study, we evaluated the results of single-stage revision of chronically infected total hip arthroplasty (THA) using broad inclusion criteria and cementless implants.

Patients and Methods

Between 2010 and 2016, 126 patients underwent routine single-stage revision with cementless reconstruction with powdered vancomycin or imipenem poured into the medullary cavity and re-implantation of cementless components. For patients with a culture-negative hip, fungal infections, and multidrug-resistant organisms, a direct intra-articular infusion of pathogen-sensitive antibiotics was performed postoperatively. Recurrence of infection and clinical outcomes were evaluated. Three patients died and 12 patients (none with known recurrent infection) were lost to follow-up. There were 111 remaining patients (60 male, 51 female) with a mean age of 58.7 (sd 12.7; 20 to 79).


Bone & Joint 360
Vol. 7, Issue 6 | Pages 15 - 18
1 Dec 2018


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 3 - 9
1 Jan 2019
Alamanda VK Springer BD

Aims

Prosthetic joint infection (PJI) remains a serious complication that is associated with high morbidity and costs. The aim of this study was to prepare a systematic review to examine patient-related and perioperative risk factors that can be modified in an attempt to reduce the rate of PJI.

Materials and Methods

A search of PubMed and MEDLINE was conducted for articles published between January 1990 and February 2018 with a combination of search terms to identify studies that dealt with modifiable risk factors for reducing the rate of PJI. An evidence-based review was performed on 12 specific risk factors: glycaemic control, obesity, malnutrition, smoking, vitamin D levels, preoperative Staphylococcus aureus screening, the management of anti-rheumatic medication, perioperative antibiotic prophylaxis, presurgical skin preparation, the operating room environment, irrigant options, and anticoagulation.


Bone & Joint 360
Vol. 8, Issue 1 | Pages 13 - 16
1 Feb 2019


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 667 - 674
1 Jun 2019
Schwarzkopf R Novikov D Anoushiravani AA Feng JE Vigdorchik J Schurko B Dwyer MK Bedair HS

Aims

With an ageing population of patients who are infected with hepatitis C virus (HCV), the demand for total knee arthroplasty (TKA) in this high-risk group continues to grow. It has previously been shown that HCV infection predisposes to poor outcomes following TKA. However, there is little information about the outcome of TKA in patients with HCV who have been treated successfully. The purpose of this study was to compare the outcomes of TKA in untreated HCV patients and those with HCV who have been successfully treated and have a serologically confirmed remission.

Patients and Methods

A retrospective review of all patients diagnosed with HCV who underwent primary TKA between November 2011 and April 2018 was conducted. HCV patients were divided into two groups: 1) those whose HCV was cured (HCV-C); and 2) those in whom it was untreated (HCV-UT). All variables including demographics, HCV infection characteristics, surgical details, and postoperative medical and surgical outcomes were evaluated. There were 64 patients (70 TKAs) in the HCV-C group and 63 patients (71 TKAs) in the HCV-UT cohort. The mean age at the time of surgery was 63.0 years (sd 7.5; 44 to 79) in the HCV-C group and 61.7 years (sd 6.9; 47 to 88) in the HCV-UT group.


Bone & Joint Research
Vol. 7, Issue 8 | Pages 517 - 523
1 Aug 2018
Tsang STJ Gwynne PJ Gallagher MP Simpson AHRW

Objectives

Periprosthetic joint infection following joint arthroplasty surgery is one of the most feared complications. The key to successful revision surgery for periprosthetic joint infections, regardless of treatment strategy, is a thorough deep debridement. In an attempt to limit antimicrobial and disinfectant use, there has been increasing interest in the use of acetic acid as an adjunct to debridement in the management of periprosthetic joint infections. However, its effectiveness in the eradication of established biofilms following clinically relevant treatment times has not been established. Using an in vitro biofilm model, this study aimed to establish the minimum biofilm eradication concentration (MBEC) of acetic acid following a clinically relevant treatment time.

Materials and Methods

Using a methicillin-sensitive Staphylococcus aureus (MSSA) reference strain and the dissolvable bead assay, biofilms were challenged by 0% to 20% acetic acid (pH 4.7) for ten minutes, 20 minutes, 180 minutes, and 24 hours.


Bone & Joint 360
Vol. 6, Issue 4 | Pages 34 - 37
1 Aug 2017


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 541 - 542
1 Apr 2006
Wilson J Tate D

National guidelines state that in patients undergoing operations the site of the procedure should be marked. In clinical practice the same marker is used repeatedly. We are not aware of any investigation regarding the theoretical risk of transferring organisms such as methicillin-resistant Staphyloccocus aureus (MRSA) between patients by a skin marker.

In an experimental setting, Penflex and Viomedex skin markers were tested 30 times each after contaminating them with a standard inoculum of MRSA. The survival of the organism on the tip of the markers was assessed by culture on MRSA-indicator nutrient agar plates at 0, 5, 15 and 60 minutes, 24 and 48 hours and at 1, 2, and 3 weeks after contamination.

There was a significant difference between the markers, with the Penflex showing no survival of MRSA after 15 minutes whereas the Viomedex product continued to produce MRSA cultures for up to three weeks.