Advertisement for orthosearch.org.uk
Results 1 - 100 of 130
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 227 - 232
1 Feb 2019
Walker T Rutkowski L Innmann M Panzram B Herre J Gotterbarm T Aldinger PR Merle C

Aims. The treatment of patients with allergies to metal in total joint arthroplasty is an ongoing debate. Possibilities include the use of hypoallergenic prostheses, as well as the use of standard cobalt-chromium (CoCr) alloy. This non-designer study was performed to evaluate the clinical outcome and survival rates of unicondylar knee arthroplasty (UKA) using a standard CoCr alloy in patients reporting signs of a hypersensitivity to metal. Patients and Methods. A consecutive series of patients suitable for UKA were screened for symptoms of metal hypersensitivity by use of a questionnaire. A total of 82 patients out of 1737 patients suitable for medial UKA reporting cutaneous metal hypersensitivity to cobalt, chromium, or nickel were included into this study and prospectively evaluated to determine the functional outcome, possible signs of hypersensitivity, and short-term survivorship at a minimum follow-up of 1.5 years. Results. At a mean follow-up of three years (1.5 to 5.7), no local or systemic symptoms of hypersensitivity to metal were observed. One patient underwent revision surgery to a bicondylar prosthesis due to a tibial periprosthetic fracture resulting in a survival rate of 98.8% (95% confidence interval (CI) 91.7 to 99.8; number at risk, 28) at three years with the endpoint of revision for any reason and a survival rate of 97.6% (95% CI 90.6 to 99.3; number at risk, 29) for the endpoint of all reoperations. Clinical outcome was good to excellent with a mean Oxford Knee Score of 42.5 (. sd. 2.5; 37 to 48). Conclusion. This study is the first demonstrating clinical results and survival analysis of UKA using a CoCr alloy in patients with a history of metal hypersensitivity. Functional outcome and survivorship are on a high-level equivalent to those reported for UKA in patients without a history of metal hypersensitivity. No serious local or systemic symptoms of metal hypersensitivity could be detected, and no revision surgery was performed due to an adverse reaction to metal ions


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 738 - 744
1 Jun 2008
Pang H Lo N Yang K Chong H Yeo S

We have performed a prospective double-blind, randomised controlled trial over two years to evaluate the efficacy and safety of an intra-operative peri-articular injection of triamcinolone acetonide in patients undergoing medial unicondylar knee replacement. We randomised 90 patients into two equal groups. The study group received an injection of triamcinolone acetonide, bupivacaine, and epinephrine into the peri-articular tissues at the end of the operation. The control group received the same injection mixture but without the addition of triamcinolone. The peri-operative analgesic regimen was standardised. The study group reported a significant reduction in pain (p = 0.014 at 12 hours, p = 0.031 at 18 hours and p = 0.031 at 24 hours) and had a better range of movement (p = 0.023 at three months). There was no significant difference in the rate of infection and no incidence of tendon rupture in either group. The addition of corticosteroid to the peri-articular injection after unicondylar knee replacement had both immediate and short-term benefits in terms of relief from pain, and rehabilitation with no increased risk of infection


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 104 - 104
1 Aug 2013
Khakha R Norris M Kheiran A Chauhan S
Full Access

Introduction. Unicondylar knee replacement (UKR) surgery is proven long term results in its benefit in medial compartment OA. However, its results are sensitive to component alignment with poor alignment leading to early failure. The advent of computer navigation has resulted in improved mechanical alignment, but little has been published on the outcomes of navigated UKR surgery. We present the results of 253 consecutive Computer Assisted UKR's performed by a single surgeon. Objective. Assess clinical and radiological outcomes of Computer Assisted Unicondylar Knee Replacement at 5 years follow-up. Methods. Between August 2003 and June 2007, 253 UKR's were performed by a single surgeon using the Stryker Knee navigation system. Pre-operative Knee Society Scores (KSS) were recorded. The UKR's consisted of 98 oxford UKR's and 155 MG UKR's. Tourniquet time, time to straight leg raise and time to discharge was also recorded. All patients had post op KSS scores and long leg standing radiographs. Data regarding revision surgery was also collected. Results. Pre-op mean KSS scores was 54 (24–62) and post-op scores were a mean of 89 (75–100). 92% percent of femoral components were aligned at 90+/− 4 degrees from neutral in the coronal plane whilst eighty nine percent of tibial components were aligned at 90+/− 4 degrees from neutral in the coronal plane. Mean tourniquet time was 53 minutes whilst 98% of patients had SLR at 24hours. Only two percent of patients had an overall valgus alignment of their limb at the end of the procedure on long leg radiographs. 1% of the UKRs underwent revision for loosening of the femoral component. 1 oxford UKR was revised for progression of patello-femoral disease. One MG UKR was revised for unexplained pain. Conclusion. Our single surgeon series of Computer Assisted UKR demonstrates favourable outcomes in the medium term with 98% survival at 5 years. Computer Assisted UKR allows accurate and reproducible alignment of the tibial and femoral component. We recommend the use of Computer Navigation in performing Unicondylar Knee Replacements


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 33 - 33
1 Feb 2016
Gregori A Smith J Picard F Lonner J Jaramaz B
Full Access

Utilisation of unicondylar knee arthroplasty (UKA) has been limited due in part to high revision rates. Only 8% of knee arthroplasty surgeries completed in England and Wales are UKAs. It is reported that the revision rate at 9 years for Total Knee Arthroplasty (TKA) was 3% compared to 12% for UKAs. In the last decade semi active robots have been developed to be used for UKA procedures. These systems allow the surgeon to plan the size and orientation of the tibial and femoral component to match the patient's specific anatomy and to optimise the balancing the soft tissue of the joint. The robotic assistive devices allow the surgeon to execute their plan accurately removing only ‘planned’ bone from the predefined area. This study investigates the accuracy of an imageless navigation system with robotic control for UKA, reporting the errors between the ‘planned’ limb and component alignment with the post-operative limb and component alignment using weight bearing long leg radiographs. We prospectively collected radiographic data on 92 patients who received medial UKA using an imageless robotic assisted device across 4 centres (4 surgeons). This system is CT free, so relies on accurate registration of intra-operative knee kinematic and anatomic landmarks to determine the mechanical and rotational axis systems of the lower limb. The surface of the condylar is based on a virtual model of the knee created intra-operatively by ‘painting’ the surface with the tip of a tracked, calibrated probe. The burring mechanism is robotically controlled to prepare the bone surface and remove the predefined volume of bone. The study shows the 89% of the patients' post-operative alignment recorded by the system was within 30 of the planned coronal mechanical axis alignment. The RMS error was 1.980. The RMS errors between the robotic system's implant plan and the post-operative radiographic implant position was; femoral coronal alignment (FCA) 2.6o, tibial coronal alignment (TCA) 2.9o and tibial slope (TS) 2.9o. In conclusion, the imageless robotic surgical system for UKA accurately prepared the bone surface of the tibia and femur which resulted in low errors when comparing planned and achieved component placement. This resulted in a high level of accuracy in the planned coronal mechanical axis alignment compared to that measured on post-operative radiographs


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 152 - 152
1 Jul 2014
Simons M Riches P
Full Access

Summary Statement. Uptake of robotically-assisted orthopaedic surgery may be limited by a perceived steep learning curve. We quantified the technological learning curve and 5 surgeries were found to bring operating times to appropriate levels. Implant positioning was as planned from the outset. Introduction. Compared to total knee replacement, unicondylar knee replacement (UKR) has been found to reduce recovery time as well as increase patient satisfaction and improve range of motion. However, contradictory evidence together with revision rates concern may have limited the adoption of UKR surgery. Semi-active robotically-assisted orthopaedic tools have been developed to increase the accuracy of implant position and subsequent mechanical femorotibial angle to reduce revision rates. However, the perceived learning curve associated with such systems may cause apprehension among orthopaedic surgeons and reduce the uptake of such technology. To inform this debate, we aimed to quantify the learning curve associated with the technological aspects of the NavioPFS™ (Blue Belt Technologies Inc., Pittsburgh, USA) with regards to both operation time and implant accuracy. Methods. Five junior orthopaedic trainees volunteered for the study following ethical permission. All trainees attended the same initial training session and subsequently each trainee performed 5 UKR surgeries on left-sided synthetic femurs and tibiae (model 1146–2, Sawbones-Pacific Research Laboratories Inc, Vashon, WA, USA). A few days lapsed between surgeries, which were all completed in a two week window. Replica Tornier HLS Uni Evolution femoral and tibial implants (Tornier, France) were implanted without cementation. Each surgery was videoed and timings taken for key operation phases, as well as the overall operative time. A ball point probe with four reflective spherical markers attached was used to record the position of manufactured divots on the implant, which allowed the 3D position of the implant to be compared to the planned position. Absolute translational and rotational deviations from the planned position were analysed. Results. Total surgical time decreased significantly with surgery number (p < 0.001) from an initial average of 85 minutes to 48 minutes after 5 surgeries. All stages, except the cutting tool set up, demonstrated a significant difference in operative time with increasing number of surgeries performed (all p < 0.05) with the cutting phase decreasing from 41 to 23 minutes (p < 0.001). The translational and rotational accuracy of the implants did not significantly vary with surgery number. Discussion and Conclusion. The accuracy in implant position obtained by trainee surgeons on synthetic bones were similar to published data for experienced orthopaedic surgeons on other systems on cadavers. Whilst cadaver operations increase the complexity of operation, this should not theoretically affect the robotic system in preventing innaccurate implantation. Moreover, the fact that this accuracy was obtainable on the first surgery clearly demonstrates the system's ability in ensuring accurate implantation. Five surgeries dramatically reduced the total operative time, and moreover, the trend suggests that more surgeries would further decrease the total operation time. It was not the intention of the study to compare absolute trainee times on synthetic bones to surgeons with cadavers, but the learning curve of the protocol and technology suggests a halving of the operation time after 5 sessions would not be unrealistic


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_16 | Pages 25 - 25
1 Oct 2014
Picard F Gregori A Bellemans J Lonner J Smith J Gonzales D Simone A Jaramaz B
Full Access

For patients suffering from osteoarthritis confined to one compartment of the knee joint, a successful unicondylar knee arthroplasty (UKA) has demonstrated an ability to provide pain relief and restore function while preserving bone and cruciate ligaments that a total knee arthroplasty (TKA) would sacrifice. Long-term survival of UKA has traditionally been inconsistent, leading to decreased utilisation in favour of alternative surgical treatment. Robot-assisted UKA has demonstrated an ability to provide more consistent implantation of UKA prosthesis, with the potential to increase long-term survivorship. This study reports on 65 patients undergoing UKA using an image-free, handheld robotic assistive navigation system. The condylar surface was mapped by the surgeon intra-operatively using a probe to capture a 3-dimensional representation of the area of the knee joint to be replaced. The intra operative planning phase allows the surgeon to determine the size and orientation of the femoral and tibial implant to suit the patients’ anatomy. The plan sets the boundaries of the bone to be removed by the robotic hand piece. The system dynamically adjusts the depth of bone being cut by the bur to achieve the desired result. The planned mechanical axis alignment was compared with the system's post-surgical alignment and to post-operative mechanical axis alignment using long leg, double stance, weight bearing radiographs. All 65 knees had knee osteoarthritis confined to the medial compartment and UKA procedures were completed using the handheld robotic assistive navigation system. The average age and BMI of the patient group was 63 years (range 45–82 years) and 29 kg/m. 2. (range 21–37 kg/m. 2. ) respectively. The average pre-operative deformity was 4.5° (SD 2.9°, Range 0–12° varus). The average post-operative mechanical axis deformity was corrected to 2.1° (range 0–7° varus). The post-operative mechanical axis alignment in the coronal plane measured by the system was within 1° of intra-operative plan in 91% of the cases. 3 out of 6 of the cases where the post-operative alignment was greater than 1° resulted due to an increase in the thickness of the tibia prosthesis implanted. The average difference between the ‘planned’ mechanical axis alignment and the post-operative long leg, weight bearing mechanical axis alignment was 1.8°. The average Oxford Knee Score (old version) pre and post operation was 38 and 24 respectively, showing a clinical and functional improvement in the patient group at 6 weeks post-surgery. The surgical system allowed the surgeons to precisely plan a UKA and then accurately execute their intra operative plan using a hand held robotically assisted tool. It is accepted that navigation and robotic systems have a system error of about 1° and 1mm. Therefore, this novel device recorded accurate post-operative alignment compared to the ‘planned’ post-operative alignment. The patients in this group have shown clinical and functional improvement in the short term follow up. The importance of precision of component alignments while balancing existing soft-tissue structures in UKA has been documented. Utilisation of robotic-assisted devices may improve the accuracy and long-term survivorship UKA procedure


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 68 - 68
1 Aug 2013
Smith J Picard F Rowe P Deakin A Riches P
Full Access

Unicondylar knee arthroplasty (UKA) is a treatment for osteoarthritis when the disease only affects one compartment of the knee joint. The popularity in UKA grew in the 1980s but due to high revision rates the usage decreased. A high incidence of implant malalignment has been reported when using manual instrumentation. Recent developments include surgical robotics systems with navigation which have the potential to improve the accuracy and precision of UKA. UKA was carried out using an imageless navigation system – the Navio Precision Freehand Sculpting system (Blue Belt Technologies, Pittsburgh, USA) with a medical Uni Knee Tornier implant (Tornier, Montbonnot Saint Martin, France) on nine fresh frozen cadaveric lower limbs (8 males, 1 females, mean age 71.7 (SD 13.3)). Two users (consultant orthopaedic surgeon and post doctoral research associate) who had been trained on the system prior to the cadaveric study carried out 4 and 5 implants respectively. The aim of this study was to quantify the differences between the planned and achieved cuts. A 3D image of the ‘actual’ implant position was overlaid on the planned implant image. The errors between the ‘actual’ and the planned implant placement were calculated in three planes and the three rotations. The maximum femoral implant rotational error was 3.7° with a maximum RMS angular error of 2°. The maximum femoral implant translational error was 2.6mm and the RMS translational error across all directions was up to 1.1mm. The maximum tibial implant rotational error was 4.1° with a maximum RMS angular error was 2.6°. The maximum translational error was 2.7mm and the RMS translational error across all directions was up to 2.0mm. The results were comparable to those reported by other robotic assistive devices on the market for UKA. This technology still needs clinical assessment to confirm these promising results


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 73 - 73
1 Aug 2013
Jaramaz A Nikou C Simone A
Full Access

NavioPFS™ is a hand-held robotic technology for bone shaping that employs computer control of a high-speed bone drill. There are two control modes – one based on control of exposure of the cutting bur and another based on the control of the speed of the cutting bur. The unicondylar knee replacement (UKR) application uses the image-free approach in which a mix of direct and kinematic referencing is used to define all parameters relevant for planning. After the bone cutting plan is generated, the user freely moves the NavioPFS handpiece over the bone surface, and carves out the parts of the bone targeted for removal. The real-time control loop controls the depth or speed of cut, thus resulting in the planned bone preparation. This experiment evaluates the accuracy of bone preparation and implant placement on cadaveric knees in a simulated clinical setting. Three operators performed medial UKR on two cadaver specimens (4 knees) using a proprietary implant design that takes advantage of the NavioPFS approach. In order to measure the placement of components, each component included a set of 8 conical divots in predetermined locations. To establish a shared reference frame, a set of four fiducial screws is inserted in each bone. All bones were cut using a 5 mm spherical bur. Exposure Control was the primary mode of operation for both condylar cuts – although the users utilised Speed Control to perform some of the more posterior burring activities and to prepare the peg holes. Postoperatively, positions of conical divots on the femoral and tibial implants and on the respective four fiducial screws were measured using a Microscribe digitising arm in order to compare the final and the planned implant position. All implants were placed within 1.5 mm of target position in any particular direction. Maximum translation error was 1.31 mm. Maximum rotational error was 1.90 degrees on a femoral and 3.26 degrees on a tibial component. RMS error over all components was 0.69mm/1.23 degrees. This is the first report of the performance of the NavioPFS system under clinical conditions. Although preliminary, the results are overall in accordance with previous sawbones studies and with the reports from comparable semi-active robotic systems that use real time control loop to control the cutting performance. The use of NavioPFS in UKR eliminates the need for conventional instrumentation and allows access to the bone through a reduced incision. By leveraging the surgeon's skill in manipulating soft tissues and actively optimising the tool's access to the bone, combined with the precision and reproducibility of the robotic control of bone cutting, we expect to make UKR surgery available to a wider patient population with isolated medial osteoarthritis that might otherwise receive a total knee replacement. In addition to accurate bone shaping with a handheld robotically controlled tool, NavioPFS system for UKR incorporates a CT-free planning system. This approach combines the practical advantages of not requiring pre-operative medical images, while still accurately gathering all key information, both geometric and kinematic, necessary for UKR planning


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_16 | Pages 12 - 12
1 Oct 2014
Smith J Picard F Lonner J Hamlin B Rowe P Riches P Deakin A
Full Access

Knee osteoarthritis results in pain and functional limitations. In cases where the arthritis is limited to one compartment of the knee joint then a unicondylar knee arthroplasty (UKA) is successful, bone preserving option. UKA have been shown to result in superior clinical and functional outcomes compared to TKA patients. However, utilisation of this procedure has been limited due primarily to the high revision rates reported in joint registers. Robotic assisted devices have recently been introduced to the market for use in UKA. They have limited follow up periods but have reported good implant accuracy when compared to the pre-operative planned implant placement. UKA was completed on 25 cadaver specimens (hip to toe) using an image-free approach with infrared optical navigation system with a hand held robotically assisted cutting tool. Therefore, no CT scan or MRI was required. The surface of the condylar was mapped intra operatively using a probe to record the 3 dimensional surface of the area of the knee joint to be resurfaced. Based on this data the size and orientation of the implant was planned. The user was able to rotate and translate the implant in all three planes. The system also displays the predicted gap balance graph through flexion as well as the predicted contact points on the femoral and tibial component through flexion. The required bone was removed using a bur. The depth of the cut was controlled by the robotically controlled freehand sculpting tool. Four users (3 consultant orthopaedic surgeon and a post-doctoral research associate) who had been trained on the system prior to the cadaveric study carried out the procedures. The aim of this study was to quantify the differences between the ‘planned’ and ‘achieved’ cuts. A 3D image of the ‘actual’ implant position was overlaid on the ‘planned’ implant image. The errors between the ‘actual’ and the ‘planned’ implant placement were calculated in three planes and the three rotations. The maximum femoral RMS angular error was 2.34°. The maximum femoral RMS translational error across all directions was up to 1.61mm. The maximum tibial RMS angular error was 2.60°. The maximum tibial RMS translational error across all directions was up to 1.67mm. In conclusion, the results of this cadaver study reported low RMS errors in implant position placement compared to the plan. The results were comparable with those published from clinical studies investigating other robotic orthopaedic devices. Therefore, the freehand sculpting tool was shown to be a reliable tool for cutting bone in UKA and the system allows the surgeon to plan the placement of the implant intra operatively and then execute the plan successfully


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 309 - 309
1 Mar 2004
Fuchs S Strosche H Thermann H Tinius W KŸchenmeister K
Full Access

Aims: Prospectivemulti-centre study evaluating minimally invasive unicondylar knee arthroplasty (UKA). Methods: Between 1997 and 2001 435 UKA were performed using the minimally invasive technique according to Repicci. 420 patients with an average age of 66 years were evaluated after a follow up of 32 weeks. In 96,8% the medial and in 3,2% the lateral compartement were involved. The clinical results were evaluated with the Knee Society Clinical Rating System (KSS) and correlated with Body-Mass-Index (BMI) and pain, rated on a Visual Analogue Scale (VAS). Radiographical scoring were evaluated according to Ahlback. Results: The results of the KSS show a signiþcant postoperative increase of average 73 points. 86,8% patients were conþdent with the treatment. The statistical analysis revealed correlation between pain and patients age. BMI shows signiþcant correlation with all other parameters. Conclusion: Minimally invasive unicondylar knee arthroplasty shows very good results, espeically for pain and patientsñ conþdence. BMI and arthrosis of the patella might have the gratest inßuence for the outcome. Deþcient pre- and postoperative extension might be an unsolved problem


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 88 - 88
1 Mar 2012
Petheram T Jeavons R Jennings A
Full Access

Objective. To investigate the reasons for revision of Oxford Unicondylar Knee Replacement (UKR). Does insert size used relate to requirement for revision?. Methods. We retrospectively reviewed the cases needing revision from a single surgeon consecutive series of 209 ‘Oxford’ UKRs. 10 cases required early (within 2 years) revision. The reasons for revision were investigated. A comparison of cases requiring revision by insert size implanted was made. Results. 10 cases required revision. 2 patients suffered from Sjorgens Syndrome which was undiagnosed at the time of primary surgery and underwent revision for ongoing pain, 2 cases fractured the tibia beneath the implant, 2 were revised for sepsis, and 3 cases were revised for ongoing pain without obvious cause. 1 case was revised for tibial component loosening. A significantly greater proportion of cases in which a size 6 insert was used required revision (4 of 11), compared with size 4 (1 of 44)(p=0.001) or size 5 (0 of 28)(p=0.002), and also compared with size 3 (3 of 31)(p=0.005). In cases where a size 3 insert is measured with this prosthesis, one option is to take a further tibial cut to rather use a size 6 insert. Given the five-fold increase in likelihood for requiring revision found in our series, we would recommend against this step. Conclusion. In conclusion we report a successful series of Oxford unicondylar knees taking early revision surgery as the endpoint. We recommend caution when considering a further cut when initial measurement suggests a size 3 insert, as in our series size 6 inserts showed a 5 fold increase in revision rate when compared to size 3


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 395 - 395
1 Sep 2009
Cho S Song E Seon J Park S Cho S Yoon T
Full Access

In total knee arthroplasty, navigation systems that help achieve accurate alignment of the lower limbs have been applied widely, and these techniques are currently being used in minimally invasive unicondylar knee arthroplasty (MIS UKA) with good alignment results. To the best of our knowledge, there are no studies showing whether or not MIS UKA using a navigation system has a significant influence on the clinical results. This prospective study investigated the hypothesis that minimally invasive uni-compartmental knee arthroplasty using navigation system (NA-MIS UKA) will produce better short-term clinical results than MIS UKA without navigation system. After a minimum two-year follow-up, the short-term functional results included the ranges of motion, Hospital for Special Surgery (HSS) scores, and WOMAC scores and the alignment accuracy of the components of 31 NA-MIS UKAs (NA-MIS group) compared with those of 33 MIS UKAs without a navigation system (MIS group). The surgery time was also recorded and compared. The HSS and WOMAC scores showed significant improvement at the final follow-up in both groups, showing no significant inter-group difference (p=0.071, p=0.096, respectively). The ranges of motion also showed significant improvements in both groups, but there was no significant difference between two groups (p=.687). However, the surgery time was longer in MIS group than in NA-MIS group. NA-MIS UKA produces significant improvement in the desired mechanical axis with prosthetic alignment outliers compared with that without the navigation system. However, at the final follow-up, there were no significant differences in any of the functional parameters between the two groups


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_16 | Pages 13 - 13
1 Oct 2014
Wallace D Gregori A Picard F Bellemans J Lonner J Marquez R Smith J Simone A Jaramaz B
Full Access

Unicondylar knee arthroplasty (UKA) is growing in popularity with an increase in utilisation. As a less invasive, bone preserving procedure suitable for knee osteoarthritic patients with intact cruciate ligaments and disease confined to one compartment of the knee joint. The long term survival of a UKA is dependent on many factors, including the accuracy of prosthesis implantation and soft tissue balance. Robotic assisted procedures are generally technically demanding, can increase the operation time and are associated with a learning curve. The learning curve for new technology is likely to be influenced by previous experience with similar technologies, the frequency of use and general experience performing the particular procedure. The purpose of this study was to determine the time to achievement of a steady state with regards to surgical time amongst surgeons using a novel hand held robotic device. This study examined consecutive UKA cases which used a robotic assistive device from five surgeons. The surgeons had each performed at least 15 surgeries each. Two of the surgeons had previous experience with another robotic assistive device for UKA. All of the surgeons had experience with conventional UKA. All of the surgeons have used navigation for other knee procedures within their hospital. The system uses image free navigation with infrared optical tracking with real time feedback. The handheld robotic assistive system for UKA is designed to enable precision of robotics in the hands of the surgeon. The number of surgeries required to reach ‘steady state’ surgical time was calculated as the point in which two consecutive cases were completed within the 95% confidence interval of the surgeon's ‘steady state’ time. The average surgical time (tracker placement to implant trial acceptance phase) from all surgeons across their first 15 cases was 56.8 minutes (surgical time range: 27–102 minutes). The average improvement was 46 minutes from slowest to quickest surgical times. The ‘cutting’ phase was reported as decreasing on average by 31 minutes. This clearly indicates the presence of a learning curve. The surgeons recorded a significant decrease in their surgical time where the most improvement was in the process of bone cutting (as opposed to landmark registration, condyle mapping and other preliminary or planning steps). There was a trend towards decreasing surgical time as case numbers increase for the group of five surgeons. On average it took 8 procedures (range 5–11) to reach a steady state surgical time. The average steady state surgical time was 50 minutes (range 37–55 minutes). In conclusion, the average operative time was comparable with clinical cases reported using other robotic assistive devices for UKA. All five surgeons using the novel handheld robotic-assisted orthopaedic system for UKA reported significant improvement in bone preparation and overall operative times within the first 15 cases performed, reaching a steady state in surgical times after a mean of 8 cases. Therefore, this novel handheld device has a similar learning curve to other devices on the market


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 100 - 100
1 Mar 2006
Kasis A Pacheco R Hekal W Farhan M
Full Access

We reviewed 35 patients who underwent a medial unicondylar knee replacement, with an average follow up of 4 years (for functional assessment). All patents had a weight bearing AP and lateral X rays and were clinically assessed using Hospital for Special surgery score, Bristol Knee Score and SF 36 health assessment form. Five angles were measured on the x-rays to assess the alignment of the tibial and femoral alignment. There was a significant relation between the femoral component varus/valgus angle and three sub scores (fixed flexion contracture, maximum valgus/varus and range of movement) in Bristol Knee scores. The best functional out come correlated with femoral components of 4–8 degrees of valgus


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 82 - 82
1 Aug 2013
Khamaisy S Gladnick BP Nam D Reinhardt KR Pearle A
Full Access

Lower limb alignment after unicondylar knee arthroplasty (UKA) has a significant impact on surgical outcomes. The literature lacks studies that evaluate the limb alignment after lateral UKA or compare it to alignment outcomes after medial UKA, making our understanding of this issue based on medial UKA studies. Unfortunately, since the geometry, mechanics, and ligamentous physiology are different between these two compartments, drawing conclusions for lateral UKAs based on medial UKA results may be imprecise and misleading. The purpose of this study was to compare the risk for limb alignment overcorrection and the ability to predict postoperative limb alignment between medial and lateral UKA. We evaluated the results of mechanical limb alignment in 241 patients with unicompartmental knee osteoarthritis who underwent medial or lateral UKA; there were 229 medial UKAs and 37 lateral UKAs. Mechanical limb alignment was measured in standing long limb radiographs pre and post-operatively, intra-operatively it was measured using a computer assisted navigation system. Between the two cohorts, we compared the percentage of overcorrection and the difference between post-operative alignment and alignment measured by the navigation system. The percentage of overcorrection was significantly higher in the lateral UKA group (11%), when compared to the medial UKA group (4%), (p= 0.0001). In the medial UKA group, the mean difference between the intraoperative “virtual” alignment provided by the navigation system, and the post-operative, radiographically measured mechanical axis, was 1.33°(±1.2°). This was significantly lower than the mean 1.86° (±1.33°) difference in the lateral UKA group (p=0.019). Our data demonstrated an increased risk of mechanical limb alignment overcorrection and greater difficulty in predicting postoperative alignment using computer navigation, when performing lateral UKAs compared to medial UKAs


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 108 - 108
1 Aug 2013
Khamaisy S Gladnick BP Nam D Reinhardt KR Pearle A
Full Access

Lower limb alignment after unicondylar knee arthroplasty (UKA) has a significant impact on surgical outcomes. The literature lacks studies that evaluate the limb alignment after lateral UKA or compare it to alignment outcomes after medial UKA, making our understanding of this issue based on medial UKA studies. Unfortunately, since the geometry, mechanics, and ligamentous physiology are different between these two compartments, drawing conclusions for lateral UKAs based on medial UKA results may be imprecise and misleading. The purpose of this study was to compare the risk for limb alignment overcorrection and the ability to predict postoperative limb alignment between medial and lateral UKA. We evaluated the results of mechanical limb alignment in 241 patients with unicompartmental knee osteoarthritis who underwent medial or lateral UKA; there were 229 medial UKAs and 37 lateral UKAs. Mechanical limb alignment was measured in standing long limb radiographs pre and post-operatively, intra-operatively it was measured using a computer assisted navigation system. Between the two cohorts, we compared the percentage of overcorrection and the difference between post-operative alignment and alignment measured by the navigation system. The percentage of overcorrection was significantly higher in the lateral UKA group (11%), when compared to the medial UKA group (4%), (p= 0.0001). In the medial UKA group, the mean difference between the intraoperative “virtual” alignment provided by the navigation system, and the post-operative, radiographically measured mechanical axis, was 1.33°(±1.2°). This was significantly lower than the mean 1.86° (±1.33°) difference in the lateral UKA group (p=0.019). Our data demonstrated an increased risk of mechanical limb alignment overcorrection and greater difficulty in predicting postoperative alignment using computer navigation, when performing lateral UKAs compared to medial UKAs


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 101 - 101
1 Dec 2013
Gladnick B Khamaisy S Nam D Reinhardt K Pearle A
Full Access

Introduction. Limb alignment after unicondylar knee arthroplasty (UKA) has a significant impact on surgical outcomes. The literature lacks studies that evaluate the limb alignment after lateral UKA or compare alignment outcomes between medial and lateral UKA. In this study, we retrospectively compare a single surgeon's alignment outcomes between medial and lateral UKA using a robotic-guided protocol. Methods. All surgeries were performed by a single surgeon using the same planning software and robotic guidance for execution of the surgical plan. The senior surgeon's prospective database was reviewed to identify patients who had 1) undergone medial or lateral UKA for unicompartmental osteoarthritis; and 2) had adequate pre- and post-operative full-length standing radiographs. There were 229 medial UKAs and 37 lateral UKAs in this study. Mechanical limb alignment was measured in standing long limb radiographs both pre- and post-operatively. Intra-operatively, limb alignment was measured using the computer assisted navigation system. The primary outcome was over-correction of the mechanical alignment (i.e, past neutral). Our secondary outcome was the difference between the radiographic post-operative alignment and the intra-operative “virtual” alignment as measured by the computer navigation system. This allowed an assessment of the accuracy of our navigation system for predicting post-operative limb alignment after UKA. Results. The percentage of overcorrection was significantly higher in the lateral UKA group (11%), when compared to the medial UKA group (4%), (p = 0.0001). In the medial UKA group, the mean difference between the intraoperative “virtual” alignment provided by the navigation system, and the post-operative, radiographically measured mechanical axis, was 1.33° (± 1.2°). This was significantly lower than the mean difference between these two parameters in the lateral UKA group, 1.86° (± 1.33°) (p = 0.019). Conclusions. Our data demonstrated an increased risk of “overcorrection,” and greater difficulty in predicting postoperative alignment using computer navigation, when performing lateral UKAs compared to medial UKAs


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 473 - 473
1 Apr 2004
Li M Nivbrant B Joss B Wood D
Full Access

Introduction An approximation of normal knee kinematics after knee replacement may improve knee function and implant fixation and reduce wear of the prosthesis. This study describes the knee joint kinematics after unicondylar knee arthroplasty (UKA) in general, and compares the Miller-Glante (MG, fixed bearing) and Oxford (mobile bearing) implants in particular. Methods Twenty-two knees in 17 patients (11 males, six females, mean age of 69.7 yrars) were randomized into MG (11 knees) or Oxford (11 knees). No clinical complications or signs of loosening were observed. At the one year follow-up, RSA (Radiosterometry) x-rays were taken by using two x-ray tubes positioned at knee level and exposing the knee simultaneously from the side. Four pairs of weight bearing x-ray were obtained at zero degrees, 30°, 60°, 90° of knee flexion, with zero as reference position. Tibial rotation, rollback, translation of tibia-femur contact point, and the bearing movement were analyzed using UmRSA software. Results With the MG implant, the tibia internally rotated 3.0°, 3.0°, and 4.2° respectively at 30°, 60°, and 90° of flexion, while with the Oxford implant, the tibia internally rotated 4.3°, 7.6°, and 9.5° respectively at 30°, 60°, and 90°. No significant difference was found between the two groups (P> 0.05, Repeated-measures ANOVA). The medial femoral condyle moved backward (1.8 and 1.5 mm respectively in MG and Oxford) from zero degrees to 30° of flexion. At 60°, it moved anteriorly in both knees, in MG to 0.9 mm anteriorly and in Oxford to 0.6 mm posteriorly to the reference position. At 90° the condyle moved 4.2 mm (MG) and 0.7 mm (Oxford) anteriorly to the reference position. No significant difference between the groups (P> 0.05). The femur-tibia contact point in MG moved anteriorly 2.8, 5.1, and 3.9 mm, respectively at 30°, 60°, and 90° of flexion, whereas the contact point in Oxford moved posteriorly 2.6, 1.8, 2.4 mm respectively at 30°, 60°, and 90°. A significant difference was found between the groups (P=0.003). The bearing in the Oxford implant moved backward of 2.2, 2.0, and 0.9 mm respectively at 30°, 60°, and 90° of knee flexion. Conclusions The in-vivo weight bearing 3D knee kinematics after UKA with fixed or mobile bearing was described. In MG the medial femoral condyle moved forward with knee flexion, whereas in Oxford it moved backward together with the bearing, which is closer to normal knee kinematics


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 76 - 76
1 Jan 2013
Baker P Jameson S Deehan D Gregg P Porter M Tucker K
Full Access

Background. Current analysis of unicondylar knee replacements (UKR) by national registries is based on the pooled results of medial and lateral implants. Using data from the National Joint Registry for England and Wales (NJR) we aimed to determine the proportion of lateral UKR implanted, their survival and reason for failure in comparison to medial UKR. Methods. By combining information on the side of operation with component details held on the NJR we were able to determine implant laterality (medial vs. lateral) for 32,847 of the 35,624 (92%) UKR registered before December 2010. Kaplan Meier plots, Life tables and Cox' proportion hazards were used to compare the risk of failure for lateral and medial UKRs after adjustment for patient and implant covariates. Results. 2,052 (6%) UKR were inserted on the lateral side of the knee. The rates of survival at 5 years were 93.1% (95%CI 92.7 to 93.5) for medial and 93.0% (95%CI 91.1% to 94.9%) for lateral replacements (p=0.49). The rates of failure remained equivalent after adjustment for patient age, gender, ASA grade, indication for surgery and implant type using Cox's proportional hazards (HR=0.87, 95%CI 0.68 to 1.10, p=0.24). For medial implants covariates found to influence the risk of failure were patient age (p< 0.001) and ASA grade (p=0.04). Age similarly influenced the risk of failure for lateral UKRs. Implant design (Mobile versus Fixed bearing) did not influence the risk of failure in either the medial or lateral compartment. Aseptic loosening/lysis and unexplained pain were the main reasons for revision in both groups. Conclusion. The mid-term survival of medial and lateral UKRs are equivalent. This supports the on-going use of pooled data by registries for the reporting on unicondylar outcomes in the future


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 65 - 65
1 Sep 2012
Heesterbeek P Van Der Schaaf D Jacobs W Ham AT
Full Access

Background. In a mobile-bearing unicondylar knee arthroplasty (UKA) stability is very important for the knee function and to prevent dislocation of the insert. A tension-guided technique to determine the position of the optimal posterior bone cut should theoretically lead to a better varus-valgus stability. The goal of this study was to measure the difference in valgus laxity in flexion and extension between a tension-guided and spacer-guided system for mobile-bearing UKA. Also clinical function was evaluated between the groups. Patients and Methods. A tension-guided UKA system (BalanSys. TM. , Mathys, Bettlach, Switzerland) was compared with a retrospective group of a spacer-guided system (Oxford, Biomet Ltd, Bridgend, UK). A total of 30 tension-guided UKAs were placed and compared to 35 spacer-guided prostheses. Valgus laxity was measured at least 6 months postoperatively in both groups using stress radiographs. The flexion stress radiographs were made fluoroscopically aided in 70 degrees of knee flexion. Laxity measurements in extension were performed on stress radiographs obtained with the Telos device. Knee Society Scores (KSS) were obtained at follow-up. Results. Valgus laxity in flexion was significantly higher in the tension-guided group compared to the spacer-guided group: 3.9° and 2.4°, respectively, p<0.001) In extension, valgus laxity was 1.8° in the tension-guided group compared to 2.7° in the spacer-guided group, which was significantly different (p<0.001). There was no significant difference between the two groups in the KSS at 6 months follow-up. (p=0.31). Discussion and conclusion. The tensor-guided system resulted in significantly more valgus laxity in flexion compared to the spacer-guided system. However, in extension the situation was reversed: the tension-guided system resulted in less valgus laxity than the spacer-guided system. Clinically, there were no differences between the groups. The valgus laxity found with the spacer-guided system better approximates the valgus laxity values of healthy elderly


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 33 - 33
1 Mar 2008
Deluzio K Astephen J
Full Access

The objective of this study was to determine if pre-operative gait patterns could predict which patients selected for unicondylar knee replacement (UKR) actually received a UKR or a total knee replacement (TKR). At the time of surgery, ten of the twenty-two UKR candidates presented with extensive degenerative changes and received total knee replacements. We analyzed gait, radiographic, and anthropometric data with a pattern recognition technique designed to detect biomechanical differences between the two groups. The groups were indistinguishable clinically, and radiographically, yet the pattern recognition technique identified features that completely separated the two groups based on the biomechanical differences. The objective of this study was to determine if pre-operative gait patterns could predict which patients selected for UKR actually received a UKR or a TKR. The UKR and TKR groups were indistinguishable visibly, clinically, and radiographically, yet the pattern recognition technique employed in this analysis identified features that completely separated the two groups. Biomechanical differences between the pre-operative groups could lead to more accurate diagnosis of unicompartmental knee OA as well as further understanding of the pathomechanics of knee OA. Twenty-two patients were initially diagnosed with unicompartmental knee OA of the medial side, and prescribed to receive unicompartmental knee replacements (UKR). At the time of surgery, ten of the twenty-two UKR candidates presented with more extensive degenerative changes and received total knee replacements (TKR). We measured gait data including knee joint angles forces and moments, velocity, stride length, stance percentage, and stance time as well as body mass index. Furthermore radiographic measures were taken including the Hip Knee Ankle (HKA) angle, the standing knee flexion angle, and the medial and lateral condyle joint spaces. The data were analysed using a pattern recognition technique that used principal component analysis to extract features from the data and discriminant analysis to separate the two groups. The discriminant function completely separated the UKR and TKR patients based on their pre-operative data. The most discriminatory feature represented a difference in early swing phase in the knee internal rotation moments


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 48 - 48
1 Mar 2009
Schmitt S Harman M Roessing S Hodge W
Full Access

Survivorship of unicondylar knee replacement (UKR) exceeds 85% at 10 years. During long term follow-up, progressive osteoarthritis (OA) and loosening are typical of UKR failure. The decision to revise UKR is complex as radiographic findings are not always consistent with clinical symptoms. This study of revised UKR compares intraoperative assessment of component fixation and progressive OA with prerevision radiographic evaluations. Twenty-seven UKR were retrieved from 22 female and 5 male patients. Patient age and time in situ averaged 76 (68–87) years and 79 (25–156) months, respectively. At index arthroplasty, all knees received a fixed-bearing medial UKR with cement fixation. Prior to revision, radiolucent lines and component alignment were assessed on radiographs according to Knee Society guidelines. Suspected revision reasons based on clinical and radiographic evaluation included aseptic loosening (63%), progressive OA (22%), and wear (15%). During revision surgery, component fixation was manually assessed and graded as well-fixed or loose, and progressive OA was graded using Outerbridge classification. Intraoperative and radiographic assessments were completed independently. Average Knee Society Scores declined > 30 points to 53+18 (pain) and 43+11 (function) before revision. During revision surgery, femoral and tibial component fixation were graded as loose in 19 (70%) and 9 (33%) knees, respectively. There was Grade III or IV progressive OA in the lateral or patellofemoral compartment of 15 (56%) and 16 (59%) knees, respectively. Radiolucent lines were evident in 8 of 19 loose femoral components and 5 of 9 loose tibial components. In contrast, 3 of 8 well-fixed femoral components and 6 of 18 well-fixed tibial components had radiolucent lines. There were 11 loose femoral components and 4 loose tibial components without radiolucent lines. Radiographic limb alignment averaged 3°+3° valgus immediately after index UKR. Change in limb alignment ranged from 0° to 17° at revision. Tibial or femoral component alignment changed 5° to 9° in 12 (44%) knees and > 10° in 5 (19%) knees. Eight of these 17 knees (47%) had malaligned components graded as loose. The prevalence of progressive OA at revision UKR was more than double occurrence suspected from radiographs. Interpreting radiographic indications for loosening was difficult. Radiolucent lines predicted loosening in 46% (13/28) of the components graded as loose and falsely predicted loosening in 35% (9/26) of the components graded as well-fixed. Radiolucent lines were absent in 15/28 (54%) of the loose components and changes in component alignment > 5° were associated with component loosening in < 50% of the knees. Rigorous attention to clinical symptoms and careful interpretation of radiographic phenomena are needed to determine indications for revision in UKR patients


Purpose. The purpose of this study was to examine the progression of osteoarthritis (OA) on patella-femoral joint (PFJ) after open wedge high tibial osteotomy (OWHTO) and unicondylar knee arthroplasty (UKA) in correlation with pain and functional outcomes. Methods. We conducted a retrospective analysis of 101 knees (89 patients), which received an OWHTO in 42 knees and UKA in 59 knees between 2003 and 2008 with minimum 5-years follow-up. Preoperative and the last follow-up radiologic evaluations were performed on the specific radiographic parameters that reflect the patella and knee alignment. Progressions of OA on PFJ at pre-operation and the last follow up were assessed and compared with modified OA grading system. The patella-femoral (PF) pain and function score were recorded using modified PF scoring system at the last follow up. Results. Among the radiologic parameters, mechanical axis (MA) and lateral patella tilt (LPT) showed statistically significant differences between OWHTO and UKA. Most of cases showed no progression or just only 1 grade step-up progression on PFJ in both groups and the amount of progression showed no statistical significant between OWHTO and UKA. In comparison of the preoperative and the final follow-up OA grades, medial PFJ in UKA group showed statistically significant differences. The PF pain and function score were comparable in both groups at the final follow up which showed no statistical differences regardless of OA progression. Conclusions. Overall, 40 ∼ 70% of cases did not occurred the progression of OA in PFJ after OWHTO and UKA. Additionally, at last follow up, the most cases showed the grade 0 or 1 OA in PFJ of both groups. Compared with HTO group, in UKA group, there were tendency of more progression of PFJ compared with preoperative OA status. Finally the degree of OA progressions did not affect the PF pain and functional outcomes


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 76 - 76
1 Aug 2012
Tu Y Xue H Liu X Cai M Xia Z
Full Access

Intramedullary (IM) femoral alignment guide for unicondylar knee arthroplasty (UKA) is a classic and generally accepted technique to treat unicompartmental knee osteoarthritis. However, IM system has a risk of excessive blood loss, fat embolism and activation of coagulation.Moreover, the implant placement and limb alignment may be less accurate in IM for UKA than total knee arthroplasty. So we try to use extramedullary (EM) femoral alignment for UKA to avoid above disadvantages. To our knowledge, few current studies have been reported by now. We reported a series of cases treated through a newly developed EM technique and evaluated the accuracy of femoral component alignment and preliminary clinical results. Between January 2009 and January 2010, 11 consecutive patients(15 knees)consisting of 8 males and 3 females were enrolled. There were 7 cases in unilateral knee and 4 cases in bilateral knees. The mean age was 65.2 years (range 60∼72 years). Incision, surgical time, blood loss and complications were measured. The pre- and post operative function of the knees were evaluated by HSS score system. The pre- and postoperative femoral component alignment was measured and compared. All cases were followed up for average 15 months (10-22 months). The mean length of incision was 7.2cm (range 6 to 8cm), the mean surgical time was 115.0min(range 90 to 125min),the mean blood loss was 50.8ml (range 50 to 80ml). The mean preoperative HSS score increased from 75 (range 63 to 83) to 95 (range 88 to 97) postoperatively (p<0.05). All femoral components were within the recommended range for varus/valgus (±10 degree) and lexion/extension (±5 degree) angle. None had complications associated with reamed canal injury. By using our EM technique, we could achieve an accurate femoral component alignment and satisfactory clinical effect. However, strict comparison between EM and cconventional IM technique and large amount of cases are essential. Further mid- and long-term studies are required


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1641 - 1648
1 Dec 2012
Baker PN Jameson SS Deehan DJ Gregg PJ Porter M Tucker K

Current analysis of unicondylar knee replacements (UKRs) by national registries is based on the pooled results of medial and lateral implants. Consequently, little is known about the differential performance of medial and lateral replacements and the influence of each implant type within these pooled analyses. Using data from the National Joint Registry for England and Wales (NJR) we aimed to determine the proportion of UKRs implanted on the lateral side of the knee, and their survival and reason for failure compared with medial UKRs. By combining information on the side of operation with component details held on the NJR, we were able to determine implant laterality (medial versus lateral) for 32 847 of the 35 624 unicondylar replacements (92%) registered before December 2010. Of these, 2052 (6%) were inserted on the lateral side of the knee. The rates of survival at five years were 93.1% (95% confidence interval (CI) 92.7 to 93.5) for medial and 93.0% (95% CI 91.1 to 94.9) for lateral UKRs (p = 0.49). The rates of failure remained equivalent after adjusting for patient age, gender, American Society of Anesthesiologists (ASA) grade, indication for surgery and implant design using Cox’s proportional hazards method (hazard ratio for lateral relative to medial replacement = 0.88 (95% CI 0.69 to 1.13); p = 0.32). Aseptic loosening/lysis and unexplained pain were the main reasons for revision in both groups, although the reasons did vary depending on whether a mobile- or a fixed-bearing design was used. At a maximum of eight years the mid-term survival rates of medial and lateral UKRs are similar.


Introduction: Unicondylar knee arthroplasty (UKA) has seen a resurgence in the past decade. Perpetuation of this trend can only be supported through prospective demonstration of efficacy with validated outcomes measures. Materials & Methods: Thirty-three consecutive cemented medial Miller-Galante UKA’s (Zimmer, Warsaw, IN) were performed in 32 patients (7 males/25 females; mean age of 67 ± 9 years). Average weight, height, and body mass index (BMI) of the patient population was 189 ± 31 lbs (Range, 145–293), 65 ± 4 in (range, 60–75), and 33 ± 5 BMI (range, 25–43), respectively. Average polyethylene thickness (as labelled) for this cohort was 8.3mm (range, 8–12mm). Outcomes were prospectively assessed via the SF-12, WOMAC, and Knee Society Score (KSS). No patients were lost to follow-up. Kaplan-Meier survivorship and Student’s t-test were performed using GraphPad Prism 4 software (GraphPad Software Inc., San Diego, CA). Results: Minimum follow-up was 39 months with a mean follow up period of 49 (range, 39–59) months. One knee was converted at 6 months at another institution to a TKA. Kaplan-Meier survivorship analysis reported 97% survivorship at 59 months (95% CI). Of the 32 knees remaining, mean preoperative KSS and WOMAC pain scores improved significantly from 52 ± 7 (range, 37–67) to 89 ± 9 (range, 67–100) (p< 0.0001) and from 40 ± 22 (range, 0–80) to 93 ± 14 (range, 35–100) (p< 0.0001), respectively. Additionally, average SF-12 Physical Component scores significantly increased from 30 ± 7 (range, 18–51) at baseline to 49 ± 10 (range, 28–59) at time of follow-up (p< 0.0001). Overall stiffness and physical function assessed via the WOMAC index also exhibited statistically significant improvement, bettering from mean baseline scores of 54 ± 24 (range, 0–100) and 52 ± 19 (range, 25–87) to 84 ± 19 (range, 50–100, p< 0.0001) and 88 ± 15 (range, 44–100, p< 0.0001), respectively. No significant cement/bone interface radiolucencies were found upon thorough radiographic review at 3 years post UKA. Discussion & Conclusion: The significant improvements observed in knee function & stiffness, and decreases in pain at a mean of 4 years after medial UKA are encouraging. Coinciding results from the physical component of the SF-12 assessment indicate reassurance of physical improvements regarding patient lifestyle. 97% survivorship in the short term would be discouraging if not for the specific circumstances of the sole conversion to TKA. This specific patient went against the advice of the operative surgeon and solicited services at an outside institution in conversion to a TKA despite markedly improved function (Pre-op/3 month post-op WOMAC and KSS of 30/75 and 60/91). Clinical and radiographic follow-up will continue in order to assess the long-term efficacy of medial UKA with the Miller-Galante prosthesis using strict patient selection criteria


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 20 - 20
1 Oct 2020
Gazgalis A Neuwirth AL Shah R Cooper HJ Geller JA
Full Access

Introduction

Both mobile bearing and fixed bearing unicompartmental knee arthroplasty (UKA) have demonstrated clinical success. However, much debate persists about the superiority of a single design. Currently most clinical data is based on high volume centers data, however to reduce bias, we undertook a through review of retrospective national joint registries. In this study, we aim to investigate UKA implant utilization and survivorship between 2000 and 2018.

Methods

Ten annual joint registry reports of various nations were reviewed. Due to the variable statistical methods of reporting implant use and survivorship we focused on three registries: Australia (AOANJRR), New Zealand (NZJR), United Kingdom (NJR) for uniformity. We evaluated UKA usage, survivorship, utilization and revision rates for each implant. Implant survivorship was reported in the registries and was compared within nations due to variation in statistical reporting.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 919 - 927
1 Jul 2012
Baker PN Petheram T Jameson SS Avery PJ Reed MR Gregg PJ Deehan DJ

Following arthroplasty of the knee, the patient’s perception of improvement in symptoms is fundamental to the assessment of outcome. Better clinical outcome may offset the inferior survival observed for some types of implant. By examining linked National Joint Registry (NJR) and patient-reported outcome measures (PROMs) data, we aimed to compare PROMs collected at a minimum of six months post-operatively for total (TKR: n = 23 393) and unicondylar knee replacements (UKR: n = 505). Improvements in knee-specific (Oxford knee score, OKS) and generic (EuroQol, EQ-5D) scores were compared and adjusted for case-mix differences using multiple regression. Whereas the improvements in the OKS and EQ-5D were significantly greater for TKR than for UKR, once adjustments were made for case-mix differences and pre-operative score, the improvements in the two scores were not significantly different. The adjusted mean differences in the improvement of OKS and EQ-5D were 0.0 (95% confidence interval (CI) -0.9 to 0.9; p = 0.96) and 0.009 (95% CI -0.034 to 0.015; p = 0.37), respectively.

We found no difference in the improvement of either knee-specific or general health outcomes between TKR and UKR in a large cohort of registry patients. With concerns about significantly higher revision rates for UKR observed in worldwide registries, we question the widespread use of an arthroplasty that does not confer a significant benefit in clinical outcome.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 31 - 31
1 Feb 2017
Barnes L
Full Access

Introduction

With the introduction of minimally invasive surgery techniques and improved polyethylene wear properties, there has been a renewed interest in Unicondylar Knee Replacements (UKR). Customized, Individually Made (CIM) UKR have been in the market for some time, and have shown to provide improved coverage and fit. The purpose of this study was to assess clinical and patient-reported outcomes utilizing CIM-UKR prostheses.

Methods

A prospectively recruited cohort of 118 patients was implanted with 120 CIM-UKR (110 medial/10 lateral) at multiple centers across the US. Patients were diagnosed with uni-compartmental osteoarthritis of the medial or lateral compartment. Patients with compromised cruciate or collateral ligaments or having a varus/valgus deformity <15° were excluded. Patients were assessed for Knee Society Knee and Function Scores, WOMAC & ROM pre-operatively (120 patients), at 6-weeks post-op (119), 6-months post-op (71 optional visit), 1 year post-op (113) and 2 years post-operatively (96). For the 3 and 4 year post-operative time points, patients were contacted to report on any possible adverse events.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 66 - 66
1 Dec 2013
Gladnick B Nam D Khamaisy S Paul S Pearle A
Full Access

Introduction:

Two fixed bearing options exist for tibial resurfacing when performing unicompartmental knee arthroplasty (UKA). Inlay components are polyethylene-only implants inserted into a carved pocket on the tibial surface, relying upon the subchondral bone to support the implant. Onlay components have a metal base plate and are placed on top of a flat tibial cut, supported by a rim of cortical bone. To our knowledge, there is no published report that compares the clinical outcomes of these two implants using a robotically controlled surgical technique. We performed a retrospective review of a single surgeon's experience with Inlay versus Onlay components, using a robotic-guided protocol.

Methods:

All surgeries were performed using the same planning software and robotic guidance for execution of the surgical plan (Mako Surgical, Fort Lauderdale, FL). The senior surgeon's prospective database was reviewed to identify patients with 1) medial-sided UKA and 2) at least two years of clinical follow up. Eighty-six patients met these inclusion/exclusion criteria: 41 Inlays and 45 Onlays. Five patients underwent a secondary or revision procedure during the follow up period and were considered separately. Our primary outcome was the WOMAC score, subcategorized by the Pain, Stiffness, and Function sub-scores. The secondary outcome was need for secondary surgery. Continuous variables were analyzed using the two-tailed Student's t-test; categorical variables were analyzed using Fisher's exact test.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 155 - 155
1 Jan 2016
Zuiderbaan H Khamaisy S Thein R Nawabi DH Ishmael C Paul S Lee Y Pearle A
Full Access

Introduction

Historically, the outcomes of knee replacement were evaluated based on implant longevity, major complications and range of motion. Over the last recent years however, there has been an intensively growth of interest in the patient's perception of functional outcome. However, the currently used patient related outcome (PRO) scores are limited by ceiling effects which limit the possibility to distinguish between good and excellent results post knee arthroplasty. The Forgotten Joint Score (FJS) is a new PRO score which is not influenced by ceiling effects, therefore making it the ideal instrument to compare functional outcome between various types of implants. It is based on the thought that the ultimate goal in joint arthroplasty is the ability of a patient to forget their artificial joint in everyday life.

The aim of this study is to compare the FJS between patients who undergo TKA and patients who undergo medial UKA at least 12 months post-operatively. We hypothesized that the UKA which is less extensive surgical procedure will present better FJS than TKA, even 12 month postoperative.

Methods

All patients who underwent medial UKA or TKA were contacted 12 months post-operatively. They were asked to complete the FJS, the Western Ontario and McMasters Universities Osteoarthritis index (WOMAC) and the EuroQol-5D (EQ-5D). A priori power analysis was conducted using two-sample t-test. 64 patients in each group were needed to reach 80% power for detecting a 12 point (SD 24) significant difference on the FJS scale with a two-sided significant level of 0.05. A p-value <0.05 was considered as statistically significant.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 413 - 413
1 Jul 2010
Eardley W Baker P Jennings A
Full Access

Background: In a recent publication from the National Joint Registry it was suggested that prosthesis type influenced patient satisfaction at one year following knee arthroplasty. In this report Unicondylar Replacement (UKR) was associated with lower levels of patient satisfaction when compared to cemented TKR. The unicondylar group did however have a significantly lower Oxford Knee Score (OKS) than the TKR group and this occurred irrespective of patient age.

A common perception is that UKR is only offered to patients with lesser disease, with a decreased clinical profile. This may explain their higher levels of dissatisfaction as the overall change in their OKS from pre to post operation would be relatively smaller than for TKR.

Aim: We hypothesised that patients listed for UKR have less severe disease and therefore a lower preoperative OKS when compared to TKR.

Methods: After sample size calculation we retrospectively analysed 76 patients who underwent either UKR or TKR under the care of a single surgeon. OKS was recorded at a dedicated pre-assessment clinic. The decision to offer UKR was based on clinical and radiological criteria as outlined by the Oxford group.

Results: There were 38 patients in either group. The mean pre-operative OKS was 39.5 (26–56, SD 7.6) in the UKR group and 41.6 (31–51, SD 5.7) in the TKR group. There was no statistical difference between these two groups (p=0.18).

Discussion: Patients listed for knee replacement have significant pain and functional impairment. In our population those suitable for UKR have similarly severe symptoms to those who do not meet the criteria for UKR and are only eligible for TKR. It remains unclear why patients undergoing UKR should be less satisfied when they have better post operative patient reported outcome scores. It emphasizes the need for careful patient selection and counselling in patient undergoing UKR.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 42 - 42
1 Jul 2012
Hassaballa M Murray J Robinson J Porteous A Newman J
Full Access

Introduction

Kneeling ability is better in unicompartmental than total knee arthroplasty. There is also an impression that mobile bearing knees achieve better functional outcome than their fixed bearing cousins in unicompartmental and to a lesser extent total joint arthroplasty. In the UK, the market leading unicompartmental replacement is mobile bearing.

Aim

To analyse kneeling ability after total and unicompartmental knee replacement using mobile and fixed bearing inserts.


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 42 - 49
1 Jan 2018
Walker T Zahn N Bruckner T Streit MR Mohr G Aldinger PR Clarius M Gotterbarm T

Aims

The aim of this independent multicentre study was to assess the mid-term results of mobile bearing unicondylar knee arthroplasty (UKA) for isolated lateral osteoarthritis of the knee joint.

Patients and Methods

We retrospectively evaluated 363 consecutive, lateral UKAs (346 patients) performed using the Oxford domed lateral prosthesis undertaken in three high-volume knee arthroplasty centres between 2006 and 2014. Mean age of the patients at surgery was 65 years (36 to 88) with a mean final follow-up of 37 months (12 to 93)


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1649 - 1656
1 Dec 2014
Lindberg-Larsen M Jørgensen CC Bæk Hansen T Solgaard S Odgaard A Kehlet H

We present detailed information about early morbidity after aseptic revision knee replacement from a nationwide study. All aseptic revision knee replacements undertaken between 1st October 2009 and 30th September 2011 were analysed using the Danish National Patient Registry with additional information from the Danish Knee Arthroplasty Registry. The 1218 revisions involving 1165 patients were subdivided into total revisions, large partial revisions, partial revisions and revisions of unicondylar replacements (UKR revisions). The mean age was 65.0 years (27 to 94) and the median length of hospital stay was four days (interquartile range: 3 to 5), with a 90 days re-admission rate of 9.9%, re-operation rate of 3.5% and mortality rate of 0.2%. The age ranges of 51 to 55 years (p = 0.018), 76 to 80 years (p < 0.001) and ≥ 81 years (p < 0.001) were related to an increased risk of re-admission. The age ranges of 76 to 80 years (p = 0.018) and the large partial revision subgroup (p = 0.073) were related to an increased risk of re-operation. The ages from 76 to 80 years (p < 0.001), age ≥ 81 years (p < 0.001) and surgical time > 120 min (p <  0.001) were related to increased length of hospital stay, whereas the use of a tourniquet (p = 0.008) and surgery in a low volume centre (p = 0.013) were related to shorter length of stay.

In conclusion, we found a similar incidence of early post-operative morbidity after aseptic knee revisions as has been reported after primary procedures. This suggests that a length of hospital stay ≤ four days and discharge home at that time is safe following aseptic knee revision surgery in Denmark.

Cite this article: Bone Joint J 2014;96-B:1649–56.


Bone & Joint Research
Vol. 11, Issue 8 | Pages 575 - 584
17 Aug 2022
Stoddart JC Garner A Tuncer M Cobb JP van Arkel RJ

Aims. The aim of this study was to determine the risk of tibial eminence avulsion intraoperatively for bi-unicondylar knee arthroplasty (Bi-UKA), with consideration of the effect of implant positioning, overstuffing, and sex, compared to the risk for isolated medial unicondylar knee arthroplasty (UKA-M) and bicruciate-retaining total knee arthroplasty (BCR-TKA). Methods. Two experimentally validated finite element models of tibia were implanted with UKA-M, Bi-UKA, and BCR-TKA. Intraoperative loads were applied through the condyles, anterior cruciate ligament (ACL), medial collateral ligament (MCL), and lateral collateral ligament (LCL), and the risk of fracture (ROF) was evaluated in the spine as the ratio of the 95. th. percentile maximum principal elastic strains over the tensile yield strain of proximal tibial bone. Results. Peak tensile strains occurred on the anterior portion of the medial sagittal cut in all simulations. Lateral translation of the medial implant in Bi-UKA had the largest increase in ROF of any of the implant positions (43%). Overstuffing the joint by 2 mm had a much larger effect, resulting in a six-fold increase in ROF. Bi-UKA had ~10% increased ROF compared to UKA-M for both the male and female models, although the smaller, less dense female model had a 1.4 times greater ROF compared to the male model. Removal of anterior bone akin to BCR-TKA doubled ROF compared to Bi-UKA. Conclusion. Tibial eminence avulsion fracture has a similar risk associated with Bi-UKA to UKA-M. The risk is higher for smaller and less dense tibiae. To minimize risk, it is most important to avoid overstuffing the joint, followed by correctly positioning the medial implant, taking care not to narrow the bone island anteriorly. Cite this article: Bone Joint Res 2022;11(8):575–584


Bone & Joint 360
Vol. 12, Issue 6 | Pages 20 - 23
1 Dec 2023

The December 2023 Knee Roundup. 360. looks at: Obesity is associated with greater improvement in patient-reported outcomes following primary total knee arthroplasty; Does mild flexion of the femoral prosthesis in total knee arthroplasty result in better early postoperative outcomes?; Robotic or manual total knee arthroplasty: a randomized controlled trial; Patient-relevant outcomes following first revision total knee arthroplasty, by diagnosis: an analysis of implant survivorship, mortality, serious medical complications, and patient-reported outcome measures using the National Joint Registry data set; Sagittal alignment in total knee arthroplasty: are there any discrepancies between robotic-assisted and manual axis orientation?; Tourniquet use does not impact recovery trajectory in total knee arthroplasty; Impact of proximal tibial varus anatomy on survivorship after medial unicondylar knee arthroplasty; Bone cement directly to the implant in primary total knee arthroplasty?; Maintaining joint line obliquity optimizes outcomes in patients with constitutionally varus knees


Bone & Joint 360
Vol. 13, Issue 3 | Pages 20 - 24
3 Jun 2024

The June 2024 Knee Roundup. 360. looks at: The estimated lifetime risk of revision after primary knee arthroplasty influenced by age, sex, and indication; Should high-risk patients seek out care from high-volume surgeons?; Stability and fracture rates in medial unicondylar knee arthroplasties; Rethinking antibiotic prophylaxis for dental procedures post-arthroplasty; Evaluating DAIR: a viable alternative for acute periprosthetic joint infection; The characteristics and predictors of mortality in periprosthetic fractures around the knee; Patient health-related quality of life deteriorates significantly while waiting six to 12 months for total hip or knee arthroplasty; The importance of looking for diversity in knee implants


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 15 - 15
1 Jun 2021
Anderson M Van Andel D Israelite C Nelson C
Full Access

Introduction. The purpose of this study was to characterize the recovery of physical activity following knee arthroplasty by means of step counts and flight counts (flights of stairs) measured using a smartphone-based care platform. Methods. This is a secondary data analysis on the treatment cohort of a multicenter prospective trial evaluating the use of a smartphone-based care platform for primary total and unicondylar joint arthroplasty. Participants in the treatment arm that underwent primary total or unicondylar knee arthroplasty and had at least 3 months of follow-up were included (n=367). Participants were provided the app with an associated smart watch for measuring several different health measures including daily step and flight counts. These measures were monitored preoperatively, and the following postoperative intervals were selected for review: 2–4 days, 1 month, 1.5 month, 3 months and 6 months. The data are presented as mean, standard deviation, median, and interquartile range (IQR). Signed rank tests were used to assess the difference in average of daily step counts over time. As not all patients reported having multiple stairs at home, a separate analysis was also performed on average flights of stairs (n=214). A sub-study was performed to evaluate patients who returned to preoperative levels at 1.5 months (step count) and 3 months (flight count) using an independent samples T test or Fisher's Exact test was to compare demographics between patients that returned to preoperative levels and those that did not. Results. The mean age of the step count population was 63.1 ± 8.3 years and 64.31% were female, 35.69% were male. The mean body mass index was 31.1 ± 5.9 kg/m. 2. For those who reported multiple stairs at home, the mean age was 62.6 ± 8.3 years and 62.3% were female. The mean body mass index was 30.7 ± 5.4 kg/m. 2. . As expected, the immediate post-op (2–4 days) step count (median 1257.5 steps, IQR 523 – 2267) was significantly lower than preop (median 4160 steps, IQR 2669 – 6034, p < 0.001). Approximately 50% of patients returned to preoperative step counts by 1.5 months postoperatively with a median 4,504 steps (IQR, 2711, 6121, p=0.8230, Figure 1). Improvements in step count continued throughout the remainder of follow-up with the 6-month follow-up visit (median 5517 steps, IQR 3888 – 7279) showing the greatest magnitude (p<0.001). In patients who reported stairs in their homes, approximately 64% of subjects returned to pre-op flight counts by 3 months (p=0.085), followed similar trends with significant improvements at 6 months (p=0.003). Finally, there was no difference in age, sex, BMI, or operative knee between those that returned to mean preoperative step or flight counts by 1.5 months and 3 months, respectively. Discussion and Conclusion. These data demonstrated a recovery curve similar to previously reported curves for patient reported outcome measures in the arthroplasty arena. Patients and surgeons may use this information to help set goals for recovery following total and unicondylar knee arthroplasty using objective activity measures. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 57 - 57
7 Aug 2023
Gill J Brimm D McMeniman P McMeniman T Myers P
Full Access

Abstract. Introduction. Patient selection is key to the success of medial unicondylar knee arthroplasty (UKA). Progression of arthritis is the most common indication for revision. Various methods of assessing the lateral compartment have been used including stress radiography, radioisotope bone scanning, MRI, and visualisation at the time of surgery. Arthroscopy is another means of assessing the integrity of the lateral compartment. Methods. We used per-operative arthroscopy as a means to confirm suitability for UKA in a consecutive series of 279 Oxford medial UKA. This study reports the long-term results of a previously published cohort of knees. Our series of UKA with per-operative arthroscopy (Group 1) was compared to all Oxford UKA (Group 2) and all UKA in the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) (Group 3). Results. The 14-year cumulative percentage revision (CPR) was 18.5% (95% CI 12.7, 26.4) for group 1, 19.7% (95% CI 18.8, 20.6) for group 2, and 19.2% (95% CI 18.5, 19.8) for group 3. There was no statistically significant difference in the (CPR) for the entire period when group 1 was compared to groups 2 or 3. Progression of arthritis was the indication for revision in similar proportions for the three groups (Group 1: 32.3%, Group 2: 35.7% and Group 3: 33.5%). Following per-operative arthroscopy 21.6% (77/356) of knees underwent a change of surgical plan from UKA to TKA. Conclusion. Per-operative arthroscopy may improve medium-term medial unicompartmental knee survivorship but does not improve long-term survivorship nor reduce revision due to progression of arthritis


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 19 - 19
1 Jan 2022
Bishnoi A Hughes M Godsiff S
Full Access

Abstract. Background. The use of tourniquet in knee arthroplasty is common but in recent times, it has initiated a debate on its use. Complications from use of tourniquet are well documented in literature but there is less evidence on thigh pain, blood loss and length of stay post arthroplasty. Methods. We included 62 patients undergoing knee arthroplasty either Unicondylar knee arthroplasty or total knee arthroplasty. Patients were allocated randomly in tourniquet and without tourniquet groups. Half of the patients had UKA and other half TKA. Thigh pain was recorded using Visual analogue scale on day 1, 2 and on discharge. A drop in pre-operative and post operative haemoglobin level was recorded too. Independent sample t-test was done to compare the difference between the 2 groups mainly, drop in haemoglobin, thigh pain, knee pain and length of stay. Results. The mean drop in haemoglobin was comparable and was not statistically significant. Thigh pain on day 1 in no tourniquet group had a mean value of 0 and statistically significant difference in thigh pain at day 1,2 and discharge. In subgroup analysis between TKA and UKA the latter had improved results. Conclusions. Knee arthroplasty surgery without the use of tourniquet provides less thigh pain in the post-operative period and there isn't any significant difference in post op haemoglobin drop. None of the patient required any blood transfusion. A trend of early discharge was noted too but probably due to sample size, it wasn't statistically significant


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 44 - 44
1 Mar 2010
Oduwole K Sayana M Onayemi F McCarthy T O’Byrne J
Full Access

Background: Unicondylar knee arthroplasty (UKA) are being expanded to include younger patients with more active lifestyles because of its minimally invasive nature. Prior to expanding this role, it is important to examine mode of failure and implication of conversion to TKA in the low demand elderly patients. Aim: To ascertain the modes of early failure of unicondylar knee Arthroplasty and assess whether the conversion to TKA improved the functional scores, range of motion, pain, and patient satisfaction. Method: A retrospective study to evaluate the results of 14 revision procedures after failed unicompartmental knee arthroplasty (UKA). Patients’ operative charts were reviewed. Details of modes of failure, technical difficulty of revision including exposure, component removal, and management of bone loss were noted. Post operative functional outcome was assessed using WOMAC osteoarthritis index and SF-36. Result: Total of 106 primary unicondylar knee arthroplasty procedures was performed between 2003 and 2007 in our institution. Oxford unicondylar implant was used in all patients. 13.21% of these were revised to total knee replacement. Revisions were performed 4 months to 36 months after the primary procedure; 86% of these were required within the first 12 months. The average time to failure was 15.6 months. The modes of failure were aseptic loosening (4), progression of osteoarthritis (2), instability (3), infection (2), dislocated insert (1) and persistent pain after UKA (2). Tibia insert exchange was done in one patient and the rest were converted to primary Scorpio and PFC components. Three of the patients had significant defect in femoral condyle. Fourteen percent of cases required femoral stem extension or metal wedge augmentation. Nine of the 14 knees (64%) were followed up for an average of 15 months. The mean WOMAC and SF-36 scores at latest follow up were 33.33 and 63.79 respectively. Conclusion: Despite the advantage of minimally invasive UKA, early failure can occur in the face of good surgical technique. The higher long-term success rate claimed by implant manufacturer is challengeable and patient should be informed during consent


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 13 - 13
1 Jun 2021
Anderson M Van Andel D Foran J Mance I Arnold E
Full Access

Introduction. Recent advances in algorithms developed with passively collected sensor data from smart phones and watches demonstrate new, objective, metrics with the capacity to show qualitative gait characteristics. The purpose of this feasibility study was to assess the recovery of gait quality following primary total hip and knee arthroplasty collected using a smartphone-based care platform. Methods. A secondary data analysis of an IRB approved multicenter prospective trial evaluating the use of a smartphone-based care platform for primary total knee arthroplasty (TKA, n=88), unicondylar knee arthroplasty (UKA, n=28), and total hip arthroplasty (THA, n=82). Subjects were followed from 6 weeks preoperative to 24 weeks postoperative. The group was comprised of 117 females and 81 males with a mean age of 61.4 and BMI of 30.7. Signals were collected from the participants' smartphones. These signals were used to estimate gait quality according to walking speed, step length, and timing asymmetry. Post-operative measures were compared to preoperative baseline levels using a Signed-Rank test (p<0.05). Results. Mean walking speeds were lowest at postoperative week 2 for all three procedures (p<.001). The TKA population stabilized to preoperative speeds by week 17. For UKA cases, mean walking speeds rebounded to preoperative speed consistently by week 9 (p>.05). THA cases returned to preoperative walking speeds with a stable rebound starting at week 6 (p>.05), and improvement was seen at week 14 (p=.025). The average weekly step length was lowest in postoperative week 2 for both TKA and UKA (p<.001), and at week 3 for THA (p<.001). The TKA population rebounded to preoperative step lengths at week 9 (p=0.109), UKA cases at week 7 (p=.123), and THA cases by week 6 (p=.946). For TKA subjects, the change in average weekly gait asymmetry peaked at week 2 postoperatively (p <0.001), returning to baseline symmetry by week 13 (p=.161). For UKA cases, mean gait asymmetry also reached its maximum at week 2 (p =.006), returning to baseline beginning at week 7 (p=0.057). For THA cases mean asymmetry reached its maximum in week 2 (p <0.001) and was returned to baseline values at week 6 (p=.150). Discussion and Conclusion. Monitoring gait quality in real-world patient care following hip and knee arthroplasty using smart phone technology demonstrated recovery curves similar to previously reported curves captured by traditional gait analysis methods and patient reported outcome scores. Capturing such real-world gait quality metrics passively through the phone may also provide the advantage of removing the Hawthorne effect related to typical gait assessments and in-clinic observations, leading to a more accurate picture of patient function


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 342 - 343
1 Sep 2005
Colwell C Patil S Ezzet K Kang S D’Lima D
Full Access

Introduction and Aims: A significant proportion of patients currently undergoing total knee arthroplasty have uni-compartmental disease. Unicondylar knee replacement (UKA) offers the benefits of less bone resection and better soft tissue retention. However, knee kinematic changes after UKA have not been established. Method: A significant proportion of patients currently undergoing total knee arthroplasty have uni-compartmental disease. Unicondylar knee replacement (UKA) offers the benefits of less bone resection and better soft tissue retention. However, knee kinematic changes after UKA have not been established. Results: In the normal knee, knee flexion was accompanied by femoral rollback and tibial internal rotation. Similar patterns of rollback and rotation were seen after UKA. Surprisingly, resecting the ACL did not affect rollback or tibial rotation. However, tibial rotation was significantly different and was more variable after TKA. This suggests that loss of the ACL may not be the major cause of abnormal kinematics after TKA. Conclusion: Abnormal kinematics have been previously reported after TKA. However, UKA appeared to maintain normal kinematics. This study reported kinematic advantages to UKA, in addition to less bone resection and better recovery


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 30 - 30
1 Oct 2020
Lombardi AV Duwelius PJ Morris MJ Hurst JM Berend KR Crawford DA
Full Access

Background. The purpose of this study is to evaluate the early perioperative outcomes after primary knee arthroplasty with the use of a smartphone-based exercise and educational platform compared to a standard of care control group. Methods. A multicenter prospective randomized control trial was conducted evaluating the use of the mymobility smartphone-based care platform for primary total knee arthroplasty (TKA) and unicondylar knee arthroplasty (UKA). Patients in the control group (224 patients) received the respective institution's standard of care typically with formal physical therapy. Those randomized to mymobility treatment group (192 patients) were provided an Apple Watch and mymobility smartphone application. The treatment group was not initially prescribed physical therapy, but could if their surgeon determined it necessary. Early outcomes assessed included 90-day knee range of motion, KOOS Jr scores, 30-day single leg stance (SLS) time, Time up and Go (TUG) time and need for manipulation under anesthesia (MUA). There was no significant difference in age, BMI or gender between groups. Results. The 90-day knee flexion was not significantly different between controls (118.3±11.8) and mymobility (118.8 ±12) (p=0.7), nor was knee extension (1.6 ±3.5 vs. 1 ±3.1, p=0.16). KOOS Jr scores were not significantly different between control group (74 ±13.1) and mymobility group (71 ±13.3) (p=0.06). 30-day SLS was 22.3 ± 19.5 sec in controls and 24 ± 20.8 sec in mymobility (p=0.2). 30-day TUG times were 16 ± 44.3 sec in control and 15 ± 40.6 sec in mymobility (p=0.84). MUAs were performed in 4.02% of patients in the control group and 2.8% in the mymobility group (p=0.4%). Conclusion. The use of the mymobility care platform demonstrated similar early outcomes to traditional care models, while providing communication and insights into patient engagement with the care plan. There was no significant difference in 90-day range of motion or need for MUA


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 395 - 395
1 Apr 2004
Fuchs S Tibesku CO Laaß H Rosenbaum D
Full Access

Aim of the Study: Evaluation of differences in pro-prioception, gait analysis, electromyography in consideration of clinical results in patients with unicondylar and bicondylar knee arthroplasty. Material and Methods: 17 patients with mean age of 62.5 years were examined after a mean time of 21.5 months after unicondylar knee arthroplasty and compared with 15 patients with a mean age of 67 years and a mean time of 31.9 months after bicondylar knee arthroplasty. For clinical examination the Knee Society, Hospital for Special Surgery and Patella Score were used. Proprioception was examined using the Balance test. In addition each patient was examined by gait analysis with three-dimensional-kinematics and force plate. M. rectus femoris, M. vastus medialis/lateralis, M. semiten-dinosus, M. biceps femoris, M. tibialis anterior and M. gastrocnemius were examined by electromyography. Results: There were neither significant deviations in demographic data, clinical scores, electromyography results (except M. vastus lateralis), gait analysis nor in proprioception. Conclusion: There were no deviations in any clinical or functional results in patients with unicondylar and bicon-dylar knee arthroplasty. Because of the uncertain long term results of unicondylar knee arthroplasty in respect of loosening and development of contralateral osteoarthritis, bicondylar knee arthroplasty can be approved


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 10 - 10
1 Oct 2012
Mofidi A Lu B Goddard M Conditt M Poehling G Jinnah R
Full Access

The knee is one of the most commonly affected joints in osteoarthritis. Unicompartmental knee replacement (UKA) was developed to address patients with this disease in only one compartment. The conventional knee arthroplasty jigs, while usually being accurate, may result in the prosthesis being inserted in an undesired alignment which may lead to poor post-operative outcomes. Common modes of failure in UKA include edge loading due to incorrect sizing or positioning, development of disease in the other compartment due to over-stuffing or over-correction and early loosening or stress fractures due to inaccurate bone cuts. Computer navigation and robotically assisted unicompartmental knee replacement were introduced in order to improve the surgical accuracy of both the femoral and tibial bone cuts. The aim of this study was to assess accuracy and reliability of robotic assisted, unicondylar knee surgery in producing reported bony alignment. Two hundred and twenty consecutive patients with a mean age of 64 + 11 years who underwent successful medial robotic assisted unicondylar knee surgery performed by two senior total joint arthroplasty surgeons were identified retrospectively. The mean body mass index of the cohort was 33.5 + 8 kg/m. 2. with a minimum follow-up of 6 months (range: 6–18 months). Femoral and tibial sagittal and coronal alignments as well as the posterior slope of the tibial component were measured in the post-operative radiographs. These measurements were compared with the equivalent measurements collected during intra-operative period by the navigation to study the reliability and accuracy of femoral and tibial cuts. Radiographic evaluation was independently conducted by two observers. There was an average difference of 2.2 to 3.6 degrees between the intra-operatively planned and post-operative radiological equivalent measurements. For the femur, mean varus/valgus angulation was 2.8 + 2.5 degrees with 83% of those measured within 5% of planned. For the tibia mean varus/valgus angulation was 2.4 + 1.9 degrees with 93% within 5% of planned resection. There was minimal inter-observer variability between radiographic measurements. There were no infections in the evaluated group at the time of radiographic examination. Alignment for unicondylar knee arthroplasty is important for implant survival and is a more difficult procedure to instrument as it is a minimally invasive surgery. Assuming appropriate planning, robotically assisted surgery in unicondylar knee replacement will result in reliably accurate positioning of component and reduce early component failures caused by malpositioning. A mismatch between pre-planning and post-operative radiography is often caused by poor cementing technique of the prosthesis rather than incorrect bony cuts. Addressing these factors can lead to greater success and improved outcomes for patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 78 - 78
1 Sep 2012
Jaramaz B Nikou C
Full Access

Introduction. Precision Freehand Sculpting(PFS), is a hand-held semi-active robotic technology for bone shaping that works within the surgical navigation framework. PFS can alternate between two control modes – one based on control of exposure of the cutting bur (“Exposure Control”) and another based on the control of the speed of the cutting bur (“Speed Control”). In this study we evaluate the performance of PFS in preparing the femoral bone surface for unicondylar knee replacement (UKR). Methods. The experiment is designed to prepare a synthetic bone for unicondylar knee replacement (UKR). The implant plan is mapped to individual specimen using a jig that fit in a unique and repeatable way to all specimens. During bone preparation, the PFS handpiece and the specimen are both tracked with the Polaris Spectra (Northern Digital Inc.) using passive reflective markers. The cutting plan is specified so that the specimens can receive a specially designed implant after the cut is finished. The implant is a modified commercial design with three planar back faces and two pegs. In addition there are 10 conical divots on the implant surface that can be used to register the implant after it is placed on the prepared bone surface. The distal and distal-anterior facets were cut with a 5 mm cylindrical bur using Extension Control. The posterior facet and the post holes were cut using 6 mm spherical bur using Speed Control. Three subjects cut 5 specimens each. One subject was an experienced PFS user. The second user was somewhat less experienced, and the third user was completely inexperienced with the use of PFS. The performance was evaluated in terms of the implant fit and the performance time. The final implant fit was characterized using a MicroScribe MX desktop coordinate measuring arm. Results. The average cut times for the first two cuts combined were 4:45 min, and for the posterior cut 3:26 min. The average distances/st.dev. from the planned implant position were 0.54 /0.23 mm and the angular differences were average/st.dev. of 1.08/ 0.53 degrees. Conclusions. All specimens were cut accurately, and with clinically acceptable surface finish. No implants were significantly malpositioned, nor were any unable to be positioned due to poor fit or planar malalignment. For both experienced users, the procedure times were short, averaging below 8 min, whereas the inexperienced user demonstrated rapid improvement in performance time


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 879 - 884
1 Jul 2008
Porteous AJ Hassaballa MA Newman JH

We identified 148 patients who had undergone a revision total knee replacement using a single implant system between 1990 and 2000. Of these 18 patients had died, six had developed a peri-prosthetic fracture and ten had incomplete records or radiographs. This left 114 with prospectively-collected radiographs and Bristol knee scores available for study. The height of the joint line before and after revision total knee replacement was measured and classified as either restored to within 5 mm of the pre-operative height or elevated if it was positioned more than 5 mm above the pre-operative height. The joint line was elevated in 41 knees (36%) and restored in 73 (64%). Revision surgery significantly improved the mean Bristol knee score from 41.1 (. sd. 15.9) pre-operatively to 80.5 (. sd. 15) post-operatively (p < 0.001). At one year post-operatively both the total Bristol knee score and its functional component were significantly better in the restored group than in the elevated group (p < 0.01). Overall, revision from a unicondylar knee replacement required less use of bone graft, fewer component augments, restored the joint line more often and gave a significantly better total Bristol knee score (p < 0.02) and functional score (p < 0.01) than revision from total knee replacement. Our findings show that restoration of the joint line at revision total knee replacement gives a significantly better result than leaving it unrestored by more than 5 mm. We recommend the greater use of distal femoral augments to help to achieve this goal


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 335 - 335
1 May 2006
Volpin G Shachar R Shtarker H Gorski A Kaushanski A Daniel M
Full Access

Introduction: The optimal treatment of osteoarthritis of the medial compartment of the knee joint is still controversial. Optional procedures include arthroscopic knee debriedement, high tibial osteotomy, and total knee arthroplasty. In the last decade the use of unicompart-mental knee arthroplasty (UKA) for localized knee arthritis has become more and more common. This study reviews our experience with unicondylar meniscal bearing knee arthroplasty in patients with localized osteoarthritis of the medial compartment of the knee joint. Material & Methods: Between 2001–2004, 26 Pts. (17F, 9M; 52–74 year old, mean 63Y) underwent surgery using the Medial Oxford Unicompartmental Knee. Four of them had since been operated on their other knee, usually 1–2 years after the first UKA. The mean age at surgery was 63 years (52–74). There were 17 women and 9 males. All patients had a stable knee and their preoperative ROM was between −10 degrees to full extension and between 100 to 120 degrees of flexion. Patients were followed for 1.5 – 4 years (mean 2.5Y), and evaluated by the Knee Society Score and radiographs. Results: 24/26 (92%) patients, including the four patients who had staged bilateral procedures of both knees, had satisfactory results, of them 16/26 (61%) had excellent results and 8/26 (31%) had good results. They were almost free of pain, and most of them had marked improvement in knee function. Similar results were observed in each of both knees of the patients who had staged bilateral unicondylar knee arthroplasty. The remaining 2 patients (8%) had fair results. A second look arthroscopy of these patients revealed a progressive development of degenerative changes of the lateral compartment in one patient, and development of degenerative changes of the patella and patellar groove in the second patient. Conclusions: Based on this study it seems that unicondylar knee arthroplasty is a favourable procedure in patients with localised arthritis of the medial compartment. This procedure allows replacement of only the affected joint compartment with less bone loss, and therefore enables preservation of healthy tissue and bone. Recovery following surgery is fast, rehabilitation is quick and ambulation is early. The ideal patient for UKA is a relatively young patient with localized degenerative changes, who has a stable knee, a flexion contracture less than 15 degrees and a mechanical axis of less than 10 degrees from neutral for a varus knee, or less than 5 degrees for a valgus knee


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1597 - 1601
1 Dec 2007
Beard DJ Pandit H Gill HS Hollinghurst D Dodd CAF Murray DW

Patellofemoral joint degeneration is often considered a contraindication to medial unicompartmental knee replacement. We examined the validity of this preconception using information gathered prospectively on the intra-operative status of the patellofemoral joint in 824 knees in 793 consecutive patients who underwent Oxford unicondylar knee replacement for anteromedial osteoarthritis. All operations were performed between January 1998 and September 2005. A five-point grading system classified degeneration of the patellofemoral joint from none to full-thickness cartilage loss. A subclassification of the presence or absence of any full-thickness cartilage loss was subsequently performed to test selected hypotheses. Outcome was evaluated independently by physiotherapists using the Oxford and the American Knee Society Scores with a minimum follow-up of one year. Full-thickness cartilage loss on the trochlear surface was observed in 100 of 785 knees (13%), on the medial facet of the patella in 69 of 782 knees (9%) and on the lateral facet in 29 of 784 knees (4%). Full-thickness cartilage loss at any location was seen in 128 knees (16%) and did not produce a significantly worse outcome than those with a normal or near-normal joint surface. The severity of the degeneration at any of the intra-articular locations also had no influence on outcome. We concluded that, provided there is not bone loss and grooving of the lateral facet, damage to the articular cartilage of the patellofemoral joint to the extent of full-thickness cartilage loss is not a contraindication to the Oxford mobile-bearing unicompartmental knee replacement


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 70 - 70
1 Nov 2016
Tria A
Full Access

Bicruciate ligament retaining total knee arthroplasty preserves all of the ligaments of the knee while still addressing the ligament balance and the flexion-extension gaps. The concept of cruciate ligament preservation is not new and both Townley and Cartier designed prostheses in the late 1980s that did preserve all of the ligaments. Their results were quite acceptable for that time in knee replacement surgery but the posterior stabilised and cruciate retaining designs controlled most of the market. The surgical technique for cruciate ligament preservation was more difficult, and without clear clinical benefit, most surgeons gravitated towards the cruciate retaining and posterior stabilised designs. In the late 1990s, evaluation of the total knee arthroplasty began to assess knee kinematics in addition to pain and functional outcomes. At the same time, studies on the unicondylar knee arthroplasty demonstrated impressive scores in motion and patient satisfaction with preservation of all of the ligamentous structures of the knee. Over the past two years, new designs that preserve all of the ligaments of the knee have returned to the market. The instruments have been improved and the prostheses have been changed to respect the kinematics of the knee. Fifteen to twenty percent of all total knee replacement patients are not completely satisfied with the surgery and the authors believe that complete ligament preservation may address this complaint


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 67 - 67
1 Dec 2017
Giordano G
Full Access

INTRODUCTION. The functional and anatomical results of TKA revisions are less good than a primary TKA. The TKA revision frequency increases and we must improve our surgeries and prepare the next standard of these surgeries. The aim of this study was to evaluate the CAOS / one stage strategie to treat the knee PJIs. MATERIALS. In this prospective study, between September 2011 and December 2014, 41 patients treated for chronic knee PJI in a one stage revision. For all of them, an imageless CAOS system (ExactechGPS, Blue- Ortho, Gieres) was used. A personalised profile of revision was created. All surgeries were performed with the same protocole and by using the same Optetrak CC knee components (Exactech, Gainesville, FL). All operations were performed by a single senior surgeon. Indications for the revision TKA were (1) revision of a primary TKA or unicondylar knee arthroplasty (n=27) or (2) revision of revisionTKA (n=15). The measurement of the HKA angle, the Oxford score and the ROM were evaluated pre and post- operatively. RESULTS. 27 males and 14 females with an average age of 71 years old (55–87) were treated for a PIJ (1 unicompartimental prosthesis, 26 TKA and 15 RTKA). The mean follow-up was 41 months (30 months − 6 years). The average time of surgery was 135 mn (120–195) for an average hospitalisation duration of 10 days (7–16). No postoperative outliers were reported (mean preop.: −1,6°+/_−5,1° − Post- op. −0,3°+/_ −1,4°). The average ROM were 115° (90–130°) (Fig. 1). The rate of success for the infection was 92,7%. We report no specific CAS complications and all the navigations were finalised. In this series of complex cases, the rate of infection healing is 92,7%. DISCUSSION. Using CAOS is a safe option with no specific complication. Combined with one stage procedures, it should be an optimal medico-economical strategy for Knee revisions. This first series initiated the « GPS RTKA » project to create a dedicated software evaluated since January 2016 with immediate very good functional results and no complications. For figures and tables, please contact authors directly


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 40 - 44
1 Oct 2015
Thienpont E Lavand'homme P Kehlet H

Total knee arthroplasty (TKA) is a major orthopaedic intervention. The length of a patient's stay has been progressively reduced with the introduction of enhanced recovery protocols: day-case surgery has become the ultimate challenge. This narrative review shows the potential limitations of day-case TKA. These constraints may be social, linked to patient’s comorbidities, or due to surgery-related adverse events (e.g. pain, post-operative nausea and vomiting, etc.). . Using patient stratification, tailored surgical techniques and multimodal opioid-sparing analgesia, day-case TKA might be achievable in a limited group of patients. The younger, male patient without comorbidities and with an excellent social network around him might be a candidate. Demographic changes, effective recovery programmes and less invasive surgical techniques such as unicondylar knee arthroplasty, may increase the size of the group of potential day-case patients. . The cost reduction achieved by day-case TKA needs to be balanced against any increase in morbidity and mortality and the cost of advanced follow-up at a distance with new technology. These factors need to be evaluated before adopting this ultimate ‘fast-track’ approach. . Cite this article: Bone Joint J 2015;97-B(10 Suppl A):40–4


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 68 - 68
1 May 2016
Jones G Clarke S Jaere M Cobb J
Full Access

The treatment of patients with osteoarthritis of the knee and associated extra-articular deformity of the leg is challenging. Current teaching recognises two possible approaches: (1) a total knee replacement (TKR) with intra-articular bone resections to correct the malalignment or (2) an extra-articular osteotomy to correct the malalignment together with a TKR (either simultaneously or staged). However, a number of these patients only have unicompartmental knee osteoarthritis and, in the absence of an extra-articular deformity would be ideal candidates for joint preserving surgery such as unicompartmental knee replacement (UKR) given its superior functional outcome and lower cost relative to a TKR [1). We report four cases of medial unicondylar knee replacement, with a simultaneous extra-articular osteotomy to correct deformity, using novel 3D printed patient-specific guides (Embody, UK) (see Figure 1). The procedure was successful in all four patients, and there were no complications. A mean increase in the Oxford knee score of 9.5, and in the EQ5D VAS of 15 was observed. To our knowledge this is the first report of combined osteotomy and unicompartmental knee replacement for the treatment of extra-articular deformity and knee osteoarthritis. This technically challenging procedure is made possible by a novel 3D printed patient-specific guide which controls osteotomy position, degree of deformity correction (multi-plane if required), and orientates the saw-cuts for the unicompartmental prosthesis according to the corrected leg alignment. Using 3D printed surgical guides to perform operations not previously possible represents a paradigm shift in knee surgery. We suggest that this joint preserving approach should be considered the preferred treatment option for suitable patients


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 26 - 26
1 Apr 2017
Li L Patel A Jundi H Parmar H
Full Access

Background. Focal resurfacing can treat localised articular damage of the knee not appropriate for arthroplasty or biological repair. Independent results on these implants are limited. We previously published early results showing significantly improved Knee Injury & Osteoarthritis Outcome Score (KOOS4) without complication or re-operation, demonstrating this system gives good analgesia and functional improvement in selected patients. We present long-term follow-up of these patients. Methods. We prospectively evaluated medium- to long-term results in patients with localised, full-thickness articular cartilage defects of the knee undergoing HemiCAP resurfacing. All procedures were performed by one consultant surgeon. Post-operative rehabilitation was standardised. Outcome measures were KOOS4 score, visual analogue score (VAS), Kellgren and Lawrence arthritis grade, and re-operation rates. Results. Six patients were evaluated with mean follow-up time of 74 months (range 61–96). Mean age was 44.8 years (range 33–51). One lateral and five medial compartments were resurfaced. Mean pre-operative KOOS4 was 39.1, mean 22-month follow-up KOOS4 improved significantly to 79.6, and mean latest follow-up KOOS4 remained good at 71.3. Mean VAS was 8.8 at latest follow-up. There was no loosening, migration or increase in osteoarthritis grade. One patient underwent revision to unicondylar knee replacement for pain after three years with comparable results at another centre (medial compartment, two year follow-up pre-revision KOOS4 84.6, latest follow-up post-revision KOOS4 73.6, VAS 6). Cause of pain was unclear (heel pain causing prolonged altered weight-bearing or failure of HemiCAP). Conclusion. Our results demonstrate that the use of the joint-preserving HemiCAP system provides good pain relief and functional improvement in both the short and longer-term. Few studies assess functional outcomes of focal resurfacing for localised full thickness articular cartilage defects. Our study assesses both the contemporaneous and time-dependent behaviour of focal resurfacing. We believe this is one of the longest follow-up series to date


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 35 - 35
1 Mar 2013
Cho H Kim J
Full Access

Recent reports about the excellent clinical results of unicondylar knee arthroplasty (UKA; also known as unicompartmental knee arthroplasty), by the minimally invasive approach, have encouraged the adoption of the surgical technique. However, friction between metallic prosthetic components resulting from polyethylene wear may result in the development of metallosis and the use of metal implants has become a huge issue in the worlds recently. Here, we report a case in which a patient underwent UKA and developed metallosis in soft tissues and bone adjacent to an implanted artificial joint three years postoperatively


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 78 - 78
1 Feb 2017
Koch C Esposito C O'Dea E Bates M Wright T Padgett D
Full Access

Introduction. Robotically-assisted unicondylar knee arthroplasty (UKA) is intended to improve the precision with which the components are implanted, but the impact of alignment using this technique on subsequent polyethylene surface damage has not been determined. Therefore, we examined retrieved ultra-high-molecular-weight polyethylene UKA tibial inserts from patients who had either robotic-assisted UKA or UKA performed using conventional manual techniques and compared differences in polyethylene damage with differences in implant component alignment between the two groups. We aimed to answer the following questions: (1) Does robotic guidance improve UKA component position compared to manually implanted UKA? (2) Is polyethylene damage or edge loading less severe in patients who had robotically aligned UKA components? (3) Is polyethylene damage or edge loading less severe in patients with properly aligned UKA components?. Methods. We collected 13 medial compartment, non-conforming, fixed bearing, polyethylene tibial inserts that had been implanted using a passive robotic-arm system and 21 similarly designed medial inserts that had been manually implanted using a conventional surgical technique. Pre-revision radiographs were used to determine the coronal and sagittal alignment of the tibial components. Retrieval analysis of the tibial articular surfaces included damage mapping and 3D laser scanning to determine the extent of polyethylene damage and whether damage was consistent with edge loading of the surface by the opposing femoral component. Results. Though the individual planar alignments did not differ between the two groups, overall 69% of the 13 robotically aligned components were well-positioned in both the coronal and sagittal planes, as opposed to only 18% of the manually aligned tibial components (Fig.1). Robotically aligned inserts had significantly less pitting, burnishing, and deformation than manually aligned inserts, and the maximum surface deviations (wear and deformation) were significantly smaller, though these differences could be explained by a longer length of implantation for the manually aligned inserts. Interestingly, no difference was found in the incidence of edge loading between the robotically aligned and manually aligned groups. When comparing polyethylene damage on the basis of alignment rather than surgical technique, neither the polyethylene damage nor surface deviation was different, aside from more burnishing and deformation in mal-positioned components and greater deviation in components mal-positioned in the sagittal plane. Conclusions. Static radiographic alignment measurements were not useful in predicting the wear patterns that the tibial inserts experienced while implanted, suggesting that other factors, such as the patient's functional kinematics, influence the mechanical burden placed on the polyethylene articular surfaces (Fig. 2)


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 59 - 59
1 Aug 2013
Walkay S Buchan M
Full Access

To assess the outcome of Offloading Knee brace (V-VAS) in the treatment of osteoarthritis of the knee. A total of 147 patients with knee arthritis were included in this study. Eighty six patients were followed up retrospectively and 61 patients were followed up prospectively. Average follow up was about 3.4 years in retrospective group and 1.2 years in prospective group. The Oxford knee score, Pain score, Walking distance and Patient satisfaction were evaluated. Average oxford scores before the brace was 19 and after the brace was 32. The pain scores before and after the brace was 8 and 3 respectively. The walking distance had improved to 900 yards. The patient satisfaction was 78%. Thirteen of eighty six patients in the retrospective group discontinued the brace, of these two had high tibial osteotomy, six patients had total knee replacement, one had unicondylar knee replacement, one patient had dislocation of patella and two elderly patients were house-bound because of medical problems. The Off loading knee brace is effective in the management of osteoarthritis of the knee. Patient satisfaction is high when using the brace. However compliance may be an issue in some of the patients. Education and early appointment for brace re-fitting increases patient compliance. Bracing is a beneficial treatment for severe medial OA of the knee


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 30 - 30
1 Jul 2012
Mofidi A Lu B Conditt M Poehling G Jinnah R
Full Access

The conventional Knee arthroplasty jigs, while being usually accurate, often result in prostheses being inserted in an undesired alignment resulting in poor postoperative outcome. This is especially true about unicompartmental knee replacement. Computer navigation and roboticaly assisted unicompartmental knee replacement were introduced in order to improve surgical accuracy of the femoral and tibial bone cuts. The aim of this study was to assess accuracy and reliability of robotic assisted, unicondylar knee surgery (Makoplasty) in producing reported bony alignment. Two hundred and twenty consecutive patients who underwent medial robotic assisted unicondylar knee surgery (Makoplasty) performed by two surgeons (RJ & GP) were retrospectively identified and included in the study. Femoral and tibial sagittal and coronal alignments and posterior slope of the tibial component were measured in the post-operative radiographs. These measurements were compared with the equivalent measurements collected during intra-operative period by the navigation to study the reliability and accuracy of femoral and tibial cuts. Results. We found an average difference of 2.2 to 3.6 degrees between the intra-operatively planned and post-operative radiological equivalent measurements. In conclusion. assuming appropriate planning, robotically assisted surgery in unicondylar knee replacement will result in reliably accurate positioning of component and reduce early component failures caused by malpositioning. Mismatch between preplanning and post-op radiography is caused by poor cementing technique of the prosthesis rather than wrong bony cuts


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 154 - 154
1 Jan 2016
Zuiderbaan H Khamaisy S Thein R Nawabi DH Pearle A
Full Access

Introduction. Chronic uneven distribution of forces over the articular cartilage, which are present in OA, has been shown to be a risk factor for the development of OA. Certain regions of the articular cartilage will be exposed to increased chronic peak loads, whereas other regions encounter a corresponding relative reduction of transmitted forces. This has a well known influence on cartilage viability and is a precursor of degenerative progression. Congruence of joints has an important impact on force distribution across articular surfaces. Therefore, tibiofemoral incongruence could lead to alterations of load distribution and ultimately to progressive degenerative changes. In clinical practice the routine method for evaluation of progressive OA is analysis of joint space width (JSW) using weight bearing radiographs. Recent studies have suggested that JSW has a strong positive correlation with cartilage compression, volume and meniscal extrusion. Lateral unicondylar knee arthroplasty (UKA) has gained increasing popularity over the last decade in the treatment of isolated unicompartmental osteoarthritis (OA). However, progressive degenerative alterations of the medial compartment following lateral unicompartmental knee arthroplasty remains a leading cause of revision surgery. Therefore, the purpose of this study is to evaluate the medial compartment congruence (MCC) and joint space width (JSW) alterations following lateral UKA. Methods. The MCC of 53 knees following lateral UKA was evaluated on pre- and postoperative radiographs and compared to 41 healthy knees, using an Interative Closest Point (ICP) algorithm. The ICP algorithm calculated the Congruence Index (CI) by performing a rigid transformation that best aligns the digitized tibial and femoral surfaces (figure 1A). Inner, middle and outer JSW was measured by subdividing the medial compartment into four quarters on weight bearing tunnel view radiographs pre- and postoperatively (figure 1B). Results. The measured CI of the healthy control group was 0.99. The pre-operative CI of knees undergoing lateral UKA was 0.92, which significantly improved to 0.96 (p<0.0001) post-operatively (figure 2). Post-operatively the inner JSW increased (p=0.006) and the outer decreased (p=0.002). JSW was restored post-operatively since no significant differences were noted in all three measured post-operative JSW locations compared to the control group (figure 3). Conclusion. Our data suggests that lateral UKA improves MCC and normalizes JSW of the medial compartment, potentially preventing osteoarthritic progression in the uninvolved medial compartment


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 150 - 150
1 Jun 2012
Mofidi A Lou B Conditt M Poehling G Jinnah R
Full Access

The conventional Knee arthroplasty jigs, while being usually accurate, often result in prostheses being inserted in an undesired alignment resulting in poor postoperative outcome. This is especially true about unicompartmental knee replacement. Computer navigation and roboticaly assisted unicompartmental knee replacement were introduced in order to improve surgical accuracy of the femoral and tibial bone cuts. The aim of this study was to assess accuracy and reliability of robotic assisted, unicondylar knee surgery (Makoplasty) in producing reported bony alignment. Two hundred and twenty consecutive patients who underwent medial robotic assisted unicondylar knee surgery (Makoplasty) performed by two surgeons (RJ & GP) were retrospectively identified and included in the study. Femoral and tibial sagittal and coronal alignments and posterior slope of the tibial component were measured in the post-operative radiographs. These measurements were compared with the equivalent measurements collected during intra-operative period by the navigation to study the reliability and accuracy of femoral and tibial cuts. Results. We found an average difference of 2.2 to 3.6 degrees between the intra-operatively planned and post-operative radiological equivalent measurements. In conclusion: assuming appropriate planning, robotically assisted surgery in unicondylar knee replacement will result in reliably accurate positioning of component and reduce early component failures caused by malpositioning. Mismatch between preplanning and post-op radiography is caused by poor cementing technique of the prosthesis rather than wrong bony cuts


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1204 - 1208
1 Sep 2013
Kerens B Boonen B Schotanus MGM Lacroix H Emans PJ Kort NP

Although it has been suggested that the outcome after revision of a unicondylar knee replacement (UKR) to total knee replacement (TKR) is better when the mechanism of failure is understood, a comparative study on this subject has not been undertaken. A total of 30 patients (30 knees) who underwent revision of their unsatisfactory UKR to TKR were included in the study: 15 patients with unexplained pain comprised group A and 15 patients with a defined cause for pain formed group B. The Oxford knee score (OKS), visual analogue scale for pain (VAS) and patient satisfaction were assessed before revision and at one year after revision, and compared between the groups. The mean OKS improved from 19 (10 to 30) to 25 (11 to 41) in group A and from 23 (11 to 45) to 38 (20 to 48) in group B. The mean VAS improved from 7.7 (5 to 10) to 5.4 (1 to 8) in group A and from 7.4 (2 to 9) to 1.7 (0 to 8) in group B. There was a statistically significant difference between the mean improvements in each group for both OKS (p = 0.022) and VAS (p = 0.002). Subgroup analysis in group A, performed in order to define a patient factor that predicts outcome of revision surgery in patients with unexplained pain, showed no pre-operative differences between both subgroups. These results may be used to inform patients about what to expect from revision surgery, highlighting that revision of UKR to TKR for unexplained pain generally results in a less favourable outcome than revision for a known cause of pain. Cite this article: Bone Joint J 2013;95-B:1204–8


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 391 - 391
1 Jul 2011
Molajo A Konala P Ball S Iranpour F Nathwani D
Full Access

Reconstructive knee arthroplasty in patients with limb deformity can be a daunting and complex task. These patients are often younger and so post traumatic osteoarthritis poses a real challenge. In view of their relative youth, bone preservation would be favourable; however accurate implantation of components is essential. Formulation of a well calculated plan and accurate execution is essential for successful surgery. We report on a novel method which combines 3D CT joint analysis and computer navigation to define the deformity present pre-operatively and determine whether the proposed reconstruction is feasible. If the reconstructive surgery is feasible, an accurate calculation the correction required is performed. The planned surgery is executed using computer aided navigation surgery. Eight patients have benefited from the technique. Four patients presented with isolated medial compartment osteoarthritis and intact anterior cruciate ligament. These patients underwent 3D CT joint analysis and computer assisted navigation surgery to accurately implant unicondylar knee replacements. Four Patients presented with two or three compartment disease. These patients underwent similar 3D CT analysis and navigated Total Knee Replacement. The series demonstrates the merits of 3D CT joint analysis to accurately define deformity and therefore determine pre-operatively feasibility of corrective surgery proposed. The technique is then complimented by computer assisted navigation surgery to ensure the proposed surgical plan is accurately executed


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 6 - 6
1 May 2016
Branch S Roche M Lightcap C Conditt M
Full Access

Introduction. Recent advances in 3D printing enable the use of custom patient-specific instruments to place drill guides and cutting slots for knee replacement surgery. However, such techniques limit the ability to intra-operatively adjust an implant plan based on soft-tissue tension and/or joint pathology observed in the operating room, e.g. cruciate ligament integrity. It is hypothesized that given the opportunity, a skilled surgeon will make intra-operative adjustments based on intra-operative information not captured by the hard tissue anatomy reconstructed from a pre-operative CT scan or standing x-ray. For example, tibiofemoral implant gaps measured intra-operatively are an indication of soft-tissue tension in the patient's knee, and may influence a surgeon to adjust implant position, orientation or size. This study investigates the frequency and magnitude of intra-operative adjustments from a single orthopedic surgeon during 38 unicondylar knee arthroplasty (UKA) cases. Methods. For each patient, a pre-operative plan was created based on the bony anatomy reconstructed from the pre-operative CT. This plan is analogous to a plan created with patient-specific cutting blocks or customized implants. With robotic technology that utilizes pre-operative imaging, intra-operative navigation and robotic execution, this “anatomic” plan can be fine-tuned and adjusted based on the soft tissue envelop measured intra-operatively. The relative positions of the femur and the tibia are measured intra-operatively under a valgus load (for medial UKA, varus load for lateral UKA) for each patient from extension to deep knee flexion and used to compute the predicted space between the implants (gaps) throughout flexion. The planned position, orientation and size of the components can then be adjusted to achieve an optimal dynamic ligament balance prior to any bony cuts. This is the plan that is then executed under robotic guidance. Intra-operative adjustments are defined as any size, position or orientation changes occurring intra-operatively to the pre-operative anatomic plan. Results. The surgeon adjusted the pre-operative implant plan in 86.8% of cases, leading to combined RMS changes of 2.0 mm and 2.1 degrees to the femoral implant, and 0.9 mm and 1.4 degrees to the tibial implant. The RMS femoral implant translations and rotations were 1.0, 1.5, 0.9 mm and 1.0, 1.0, 1.7 degrees in the medial, anterior, and superior directions, respectively. The RMS tibial implant translations and rotations were 0.2, 0.4, 0.8 mm and 1.3, 0.4, 0.6 degrees in the medial, anterior, and superior directions, respectively. Implant sizes were adjusted in 36.8% of cases, with all changes occuring to the femoral implant, and 13 out of those 14 cases showing a reduction in the femoral implant size. Conclusions. These data support the hypothesis that surgical planning of UKA components based on accurate 3D dimensional reconstructions of anatomy alone is not adequate to create optimal implant gap spacing throughout flexion. Measurement and knowledge of the patient's soft tissue envelope allows for signficiant changes to the implant plan prior to any bony cuts


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 44 - 44
1 Jun 2012
Dhinsa B Nawaz Z Gallagher K Carrington R Skinner J Briggs T Bentley G
Full Access

Purpose. The rate of arthroplasty or osteotomy in patients who had undergone autologous chondrocyte implantation (ACI) for osteochondral defects in the knee was determined. Furthermore, we investigated whether any radiographic evidence of osteoarthritis (OA) prior to ACI was associated with poorer outcome following surgery. Methods. We retrospectively reviewed the medical notes and radiographs of 236 patients (mean age 34.9) who underwent ACI from 1998 to 2005 at our institution. Knee function was assessed according to the Modified Cincinnati Score (MCS) pre-operatively and at a mean of 64.3 months postoperatively (range 12 – 130). Radiographic changes were graded according to the Stanmore grading system. Results. Patients were divided into 2 groups; Group A were patients with no evidence of OA (n=72) and Group B were patients with OA (n=164). In group A, two patients required total knee replacement (TKR) or unicondylar knee replacement (UKR) and 3 required high tibial osteotomy (overall revision rate 6.9%). In group B, 34 patients required patello-femoral replacement, or UKR or TKR and 17 patients required osteotomy (overall revision rate 31.1%). This difference was significant (p < 0.01). At latest follow up, the mean MCS was significantly higher in Group A (72.5 versus 51.8, p < 0.01). Conclusions. Patients with early radiographic of evidence of OA are unlikely to gain maximum benefit from ACI. The results suggest that ACI does not prevent patients from progressing in their arthritic process and hence requiring joint replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 726 - 728
1 Sep 1995
McCallum J Scott R

Osteoarthritis of the medial compartment of the knee often shows a specific pattern of anterior wear. Review of our revisions from a series of medial metal-backed Brigham unicondylar knee replacements performed between 1983 and 1989 showed that this wear pattern was common on the tibial polyethylene surface. We reviewed these cases retrospectively to compare the pattern of preoperative erosion with the wear of the prosthesis. In all 14 knees with severe anterior wear in a unicompartmental replacement, the prearthroplasty radiographs showed similar patterns, suggesting that the implanted tibial component may continue to be subjected to the same localised stresses that precipitated the failure of the original articular cartilage. Many tibial components implanted during the 1980s had an unacceptably thin anterior rim of polyethylene and it seems that greater thickness is essential at the anterior and peripheral margins of the tibial plateau


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 385 - 385
1 Jul 2011
Malal JG Deshpande S
Full Access

Oxford medial uni compartmental knee replacement is a common and widely accepted procedure that relies on accurate positioning and alignment of the implants for optimal outcome and longevity. Posterior slope of the tibial base plate has been shown to be an important factor affecting long term survivorship. The aim of the study was to evaluate whether navigation increased the accuracy of Oxford knee replacements using the posterior slope of the tibial component as an index measure. The posterior slope of tibial trays from 58 sequential Oxford medial unicondylar knee replacements over a two year period was checked on standard lateral x-rays against the recommended range. There were 12 cases in the navigated and 46 in the conventional group across six Orthopaedic firms. The mean posterior slope for navigated and conventional implantations was 4.75 and 3.3 degrees respectively with the difference not being statistically significant. However, when considering the data for low volume surgeons, the mean posterior slope with and without navigation was 4.75 and 1.83 degrees respectively which was significant with a p value of 0.017. Navigation was also found to significantly decrease the chance of implanting the knee with the posterior slope outside the acceptable range (p=0.024). In both analyses the navigated cohort had a narrower data spread and fewer outliers compared to the conventional group. No other factors were found to significantly correlate with the posterior slope. The study suggests that navigation might help low volume surgeons in increasing the accuracy and decreasing the incidence of extreme variations from the desirable range of implant positioning for unicompartmental knee replacements


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 896 - 902
1 Jul 2009
Gulati A Chau R Pandit HG Gray H Price AJ Dodd CAF Murray DW

Narrow, well-defined radiolucent lines commonly observed at the bone-implant interface of unicompartmental knee replacement tibial components have been referred to as physiological radiolucencies. These should be distinguished from pathological radiolucencies, which are poorly defined, wide and progressive, and associated with loosening and infection. We studied the incidence and clinical significance of tibial radiolucent lines in 161 Oxford unicondylar knee replacements five years after surgery. All the radiographs were aligned with fluoroscopic control to obtain views parallel to the tibial tray to reveal the tibial bone-implant interface. We found that 49 knees (30%) had complete, 52 (32%) had partial and 60 (37%) had no radiolucent lines. There was no relationship between the incidence of radiolucent lines and patient factors such as gender, body mass index and activity, or operative factors including the status of the anterior cruciate ligament and residual varus deformity. Nor was any statistical relationship established between the presence of radiolucent lines and clinical outcome, particularly pain, assessed by the Oxford Knee score and the American Knee Society score. We conclude that radiolucent lines are common after Oxford unicompartmental knee replacement but that their aetiology remains unclear. Radiolucent lines were not a source of adverse symptoms or pain. Therefore, when attempting to identify a source of postoperative pain after Oxford unicompartmental knee replacement the presence of a physiological radiolucency should be ignored


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 332 - 332
1 Jul 2014
Abdulkarim A Motterlini N O'Donnell T Neil M
Full Access

Summary Statement. This project proves that Patellofemoral (PF) joint degeneration is not a contraindication to medial unicompartmental knee replacement. Introduction. Unicompartmental knee arthroplasty (UKA) is a recognised procedure for treatment of medial compartment osteoarthritis. Patellofemoral (PF) joint degeneration is widely considered to be a contraindication to medial unicompartmental knee replacement. We examined the validity of this preconception using information gathered prospectively on consecutive patients who underwent UKA using the Repicci II® UKA prosthesis for medial compartment osteoarthritis. Methods. We prospectively collected data on 147 consecutive patients who underwent the Repicci II® UKA for medial compartment osteoarthritis. All operations were performed between July 1999 and September 2000 by the same surgeon. The status of the PF joint was assessed intra-operatively in all patients, and accordingly patients were divided into two groups, one group with a normal PF joint, and the second group with degenerative changes of the PF joint. Variables measured for outcome included the International Knee Society (IKS) score, limb alignment, and range of motion. Radiographs were assessed for progression of disease or failure of implant. The mean follow-up was 9.4 years (range: 5–10.7 years). Patients were reviewed initially at 2 weeks, and then at 6 months post-operatively. They were subsequently reviewed on an annual basis.. All patients completed an IKS score preoperatively and at last follow-up. Age, gender, BMI, length of hospital stay, perioperative complications, all subsequent surgery, including revision of the prosthesis, and survivorship at 10 years was recorded, and results of the 2 groups compared. Results. A total of 147 patients were included in the study. None were lost to follow-up. Sixty nine had associated PF osteoarthritis (group A) while 78 patients had a normal PF compartment when assessed intra-operatively (group B). Post-operative outcomes of the two groups were compared using the ANCOVA analysis with adjustment for pre-operation values firstly, and adjusting also for gender, age, BMI and follow-up secondly. There were no significant differences in terms of IKS, alignment, and flexion between the two groups. However, patients in group B had significantly better extension post-operatively than patients in group A (p<0.05). Conclusion. We concluded that damage to the articular cartilage of the patellofemoral joint to the extent of full-thickness cartilage loss is not a contraindication to the Repicci II® unicondylar knee arthroplasty for medial compartment osteoarthritis. However, extension is significantly improved post-operatively in those patients with minimal or no PF joint degenerative disease


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 328 - 329
1 May 2010
Tatsumi I Hirakawa K Matsuda Y Tsuji K Takayanagi S Nakura N Nakasone S
Full Access

Introduction: The purpose of this study is to determine in vivo femorotibial axial rotation magnitudes and patterns in mobile-bearing posterior stabilized total knee arthroplasty (PS-TKA) and unicondylar knee arthroplasty (UKA) in deep flexion. Material and Methods: Using video fluoroscopy, 12 subjects having a mobile-bearing PS-TKA (NexGen LPS Flex) and 12 subjects having a mobile-bearing UKA (Oxford UNI) were analyzed to determine their in vivo kinematic patterns under both weight bearing and non weight bearing. All implants were implanted by the same surgeon and were judged successful clinically with no pain and ligament laxity. The femoral and tibial components were overlaid onto the fluoroscopic images using a three-dimensional automated model-fitting technique to determine joint mobility. Results: The average range of motion was 124 degrees of flexion for the PS-TKA and 137 degrees of flexion for the UKA. Although subjects in this study exhibited variable motion pattern, the common is anterior movement in extension to 45 degrees of flexion and posterior movement in 60 degrees of flexion to full flexion. The average internal rotation of the tibia was 18 degrees in UKA and 6 degrees in PS-TKA at 100 degrees of flexion to full. Incidence of lateral condylar lift off greater than 2mm was 5 in the PS-TKA and 1 in the UKA. Discussion: A medial pivot kinematic pattern was observed in deep flexion in UKA. However in extension to 45 or 60 degrees of flexion, anterior condylar movement was observed in both groups. The motion pattern of UKA in 60 degree of flexion to full was close to the natural knee motion


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 34 - 34
1 Mar 2012
Ferguson J Pandit H Price A Marks B Gill H Murray D Dodd C
Full Access

Introduction. Obesity has been considered a relative contra-indication in unicompartmental knee arthroplasty (UKA) due to fear of high wear rates, loosening and tibial collapse. The aim of this study was to investigate the impact of high body mass index (BMI) on ten-year survivorship and five-year functional outcome after Oxford UKA, a fully congruous mobile bearing design with large contact area and low wear rate. Methods. This prospective study examines a consecutive series of 595 knees (mean age 66 years, range: 33-88) undergoing Oxford UKA with a minimum 5-year follow-up. Patients were divided into three groups; Group I (Normal body weight), BMI <25 (n=171), Group II (overweight), BMI 25- 30 (n=264), and Group III (Obese), BMI ≥30 (n=160). The survivorship and functional outcome (as assessed by change in Oxford Knee Score [DeltaOKS]) and Knee Society Score (KSS) for all three groups were compared. Results. The mean follow-up was 6.3 years. There was no significant difference in the 10-year survivorship between groups (96% for all groups). Although numbers were small there was no significant difference in revision rates for patients with BMI ≥35 (n=1/38). Group III patients had a lower pre-operative OKS and lower post-operative OKS compared to groups I and II, although DeltaOKS was similar (p= .977). At last follow-up the Functional KSS was lower in group III (p=.11), although Objective KSS was not significantly different between groups (p=.954). Conclusion. Oxford UKA can be safely used in obese and morbidly-obese patients. Design features of congruous bearing and large contact area ensure low wear rates. Summary. No significant difference in revision rates noted between groups of increasing body mass index in this prospective study of outcome in patients undergoing medial Oxford unicondylar knee replacement


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 217 - 217
1 Dec 2013
Abdulkarim A Motterlini N ODonnell T Neil M
Full Access

Introduction. Unicompartmental knee arthroplasty (UKA) is a recognized procedure for treatment of medial compartment osteoarthritis. Patellofemoral (PF) joint degeneration is widely considered to be a contraindication to medial unicompartmental knee replacement. We examined the validity of this preconception using information gathered prospectively on consecutive patients who underwent UKA using the Repicci II® UKA prosthesis for medial compartment osteoarthritis. Methods. We prospectively collected data on 147 consecutive patients who underwent the Repicci II® UKA for medial compartment osteoarthritis. All operations were performed between July 1999 and September 2000 by the same surgeon. The status of the PF joint was assessed intra-operatively in all patients, and accordingly patients were divided into two groups, one group with a normal PF joint, and the second group with degenerative changes of the PF joint. Variables measured for outcome included the International Knee Society (IKS) score, limb alignment, and range of motion. Radiographs were assessed for progression of disease or failure of implant. The mean follow-up was 9.4 years (range: 5–10.7 years). Patients were reviewed initially at 2 weeks, and then at 6 months post-operatively. They were subsequently reviewed on an annual basis. All patients completed an IKS score preoperatively and at last follow-up. Age, gender, BMI, length of hospital stay, perioperative complications, all subsequent surgery, including revision of the prosthesis, and survivorship at 10 years was recorded, and results of the 2 groups compared. Results. A total of 147 patients were included in the study. None were lost to follow-up. Sixty nine had associated PF osteoarthritis (group A) while 78 patients had a normal PF compartment when assessed intra-operatively (group B). Post-operative outcomes of the two groups were compared using the ANCOVA analysis with adjustment for pre-operation values firstly, and adjusting also for gender, age, BMI and follow-up secondly. There were no significant differences in terms of IKS, alignment, and flexion between the two groups. However, patients in group B had significantly better extension post-operatively than patients in group A (p < 0.05). Conclusion. We concluded that damage to the articular cartilage of the patellofemoral joint to the extent of full-thickness cartilage loss is not a contraindication to the Repicci II® unicondylar knee arthroplasty for medial compartment osteoarthritis. However, extension is significantly improved post-operatively in those patients with minimal or no PF joint degenerative disease


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 535 - 535
1 Oct 2010
Daniilidis K Fischer F Skuginna A Skwara A Tibesku C
Full Access

Aim: Cementation of tibial implants in total knee arthroplasty is a gold-standard considering the high loosening rates of cementless implants. In contrast, only sparse data exist regarding unicondylar arthroplasty due to limited use. In this study, we compare cemented with cementless unicondylar knee arthroplasty and aim to define both clinical and radiological differences in treatment outcome. Materials and Methods: In a retrospective study, 106 patients who had undergone a medial unicondylar replacement were examined after a mean postoperative period of 8 years. Of these, 42 patients (median age 81±7 years) had received a cemented and 64 (median age 73±7 years) a cementless knee arthroplasty by the same surgeon while 7 patients were deceased or could not be reached. Well-established clinical (VAS, HSS, KSS, UCLA, WOMAC) and quality of life (SF-36) scores were used to evaluate treatment outcome. X-rays were performed to evaluate periprosthetic loosening zones, according to Ewald’s criteria. Results: The cementless patient group presented significantly better clinical scores (HSS, KSS, UCLA, WOMAC), except in the Visual Analogue Scale (VAS) for pain assessment. The quality of life was significantly better in the cementless group except in the subgroups concerning physical function, vitality and social role, which resembled normal population. Moreover, radiographic analysis using antero-posterior X-rays revealed significantly more and larger periprosthetic loosening areas in tibial zone 2 in the cementless group. Conclusion: The inferior clinical results characterising the cemented group could be attributed to the higher mean age. Regarding the radiological loosening zones, we did not detect any differences in the techniques of fixation, although physical activity and mechanical stresses were higher in the cementless group


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 69 - 69
1 Aug 2013
Smith J Blyth M Jones B MacLean A Rowe P
Full Access

Total knee arthroplasty (TKA) has been established as a successful procedure for relieving pain and improving function in patients suffering from severe knee osteoarthritis for several decades now. It involves removing bone from both the medial and lateral compartments of the knee and sacrificing one or both of the cruciate ligaments. This in turn is likely to have an impact on the patients' functional outcome. In subjects where only one compartment of the knee joint is affected with osteoarthritis then unicondylar knee arthroplasty (UKA) has been proposed as an alternative procedure to TKA. This operation preserves the cruciate ligaments and removes bone only from the affected side of the joint. As a result there is the possibility of an improved functional outcome post surgery. UKA has been associated with faster recovery, good functional outcome in terms of range of motion and it is bone sparing compared to TKA. However, the biggest obstacle to UKA success is the high failure rates. The aim of this study was to compare the functional outcome of computer navigated TKA (n=60) and UKA (n=42) patients 12 month post operation using flexible electrogoniometry. Flexible electrogoniometry was used to investigate knee joint kinematics during gait, slopes walking, stair negotiation, and when using standard and low chairs. Maximum, minimum and excursion knee joint angles were calculated for each task. The biomechanical assessment showed statistically significant improvements in the knee kinematics in terms of maximum (p<0.0004) and excursion (p<0.026) knee joint angles in the UKA patient group compared to the navigated TKA group for each of the functional tasks. There was no statistically significant difference between the minimum knee joint angles during these functional tasks (p>0.05). Therefore, UKA patients were showed to have a significantly better functional outcome in terms of the maximum knee joint angle during daily tasks. A limitation of this study is that it compares two cohorts rather than two randomised groups. It is expected that UKA patients will have a better functional outcome. Our results suggest that for patients with less severe knee osteoarthritis, UKA may offer a better functional outcome than the more common surgical option of TKA. The recent advancements in computer assisted and robotic assisted knee arthroplasty has the possibility to improve the accuracy of UKA and therefore led to the increase in confidence and in usage in a procedure which has the potential to give patients a superior functional outcome


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 70 - 70
1 Mar 2012
Hossain FS Patel S Tahmassebi J Haddad FS
Full Access

Introduction. Unicondylar knee replacements (UKR) may be more effective compared to Total knee replacements (TKR) in unicompartmental arthritis. We report patient outcomes & satisfaction data in an age matched cohort of patients with either a UKR or TKR. Method. A single unit and single surgeon series of patients were recruited. Data was retrospectively collated for 68 patients with more than 24 months follow-up. UKR was undertaken in patients with isolated medial compartment osteoarthritis; stable ACL and less than grade 3 lateral patellar changes of the Outerbridge classification. TKR was undertaken for the rest. The patients were assessed with validated knee scores including the Total Knee Function Questionnaire (TKFQ) which focuses on recreational & sporting outcomes as well as activities of daily living (ADL). Patient satisfaction and perception of knee normality was measured on a visual analogue scale. Results. 34 patients with a TKR and 34 patients with a UKR were analysed. The average ages in the TKR and UKR groups were 69.25 and 67.26 years respectively. The patients were well matched for demographics and had equivalent preoperative morbidities and scores. The UKR group had better WOMAC (p=0.003), SF36 (physical: p<0.001 mental: p=0.25), Oxford knee (p<0.001) and Knee Society scores (p=0.002, function: p<0.001). The UKR group showed better outcomes in the TKFQ including exercise and sport (p= 0.02), movement and lifestyle (p=0.02) and the ADL (p=0.002). There was however no difference in patient satisfaction scores (p=0.41) and perception of how normal the knee felt between the two groups (p=0.99). Conclusions. A UKR procedure confers better functional outcome in terms of recreation and sport compared to TKR procedures. While UKR is an appropriate choice in the elderly yet active patient with unicompartmental knee arthritis, satisfaction is similar to that of patients with a TKR reflecting higher preoperative expectations. Further work is needed to assess this


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 326 - 326
1 Jul 2008
Dawson-Bowling S Chettiar K Hussein R East D Miles K Apthorp H Butler-Manuel P
Full Access

Introduction: Debate continues regarding the optimal timing of surgery for patients requiring bilateral knee arthroplasty; we reviewed the costs, clinical and functional outcomes of 116 patients undergoing simultaneous or staged bilateral surgery using 3 different prostheses. Method: Data were retrospectively collected from 116 consecutive patients undergoing 232 knee replacements over 10 years, either simultaneously or over 2 hospital admissions (staged). Post-operative complication rate, total cost of treatment (calculated from pros-theses, theatre time, days in hospital and number of clinic attendances) and functional (HSS) score at 1 year were the outcome measures. Results: 54 patients underwent Oxford unicondylar knee replacements, 41 simultaneously, 13 staged; respective mean total costs were £9890 and £13,553 (p< 0.001). 42 patients were treated with AGC prostheses; 14 simultaneously, 28 staged, with respective total costs of £12,187 and £16,920 (p< 0.001). 10 TMK patients had simultaneous surgery (mean total cost £14,812), 10 were staged (£20,191); p< 0.001. For all 3 prostheses, there was no significant difference in complication rate or 1 year functional outcome between simultaneous and staged groups. Discussion: Some authors advocate replacing both knees simultaneously as safe and cost-effective; others report significant increases in medical and surgical morbidity. Our series shows significant cost savings with no increase in complication rate


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 33 - 33
1 Dec 2013
Cobb J Andrews B Manning V Zannotto M Harris S
Full Access

Outcome measures are an essential element of our industry: comparing a novel procedure against an established one requires a reliable set of metrics that are comprehensible to both the technologist and the layman. We surmised that a detailed assessment of function before and after knee arthroplasty, combined with a detailed set of personal goals would enable us to test the hypothesis that less invasive joint and ligament preserving operations could be demonstrated to be more successful, and cost effective. We asked the simple question: how well can people walk following arthroplasty, and can we measure this?. Materials and methods. Using a treadmill, instrumented with force plates, we developed a regime of walking at increasing speeds and on varying inclines, both up and down hill. The data from the force plates was then extracted directly, without using the proprietary software that filtered it. Code was written in matlab script to ensure that missed steps were not mistakenly attributed to the wrong leg, automatically downloading of all the gait data at all speeds and inclines. The pattern of gait of both legs could then be compared over a range of activities. Results. Wide variation is seen in gait both before and after arthroplasty. The variables that are easiest to explain are these: . width of gait – this appears to be a pre-morbid variable, not easily correctible with surgery. (figure 1). top walking speed – total knee replacement is associated with 11% lower top speeds than uni knees or normals (p < 0.05). change in stride length with increasing speed: normal people increase their walking speed by increasing both their cadence and their stride length incrementally until a top stride length is reached. Patients with a total knee replacement do not increase their stride length at a normal rate, having to rely on increasing cadence to deliver speed increase. Patients with uni or bi-compartmental knee replacements increase speed like normal people. Downhill gait: as many as 40% of fit patients with ‘well functioning’ total knee replacements choose not to walk downhill at all, while all fit patients with ‘well functioning’ partial replacements are able to do this. Those who can manage, can only manage 90% of the normal speed, unlike unis which are indistinguishable from normal (p < 0.05). Conclusions. At higher speeds and on inclines, the presence of an intact cruciate ligament couple enables a near normal gait, following both Unicondylar knee arthroplasty and Uni + PFJ arthroplasty. Total knee arthroplasty, whether cruciate retaining or sacrificing, prevents normal gait at higher speed. An intact anterior cruciate may be an essential part of gait, playing a greater role in the swing through phase of gait. Resecting it as part of an arthroplasty may not be in the best interest of the patient's gait


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 89 - 89
1 Dec 2013
Puthumanapully PK Amis A Harris S Cobb J Jeffers J
Full Access

Introduction:. Varus alignment of the knee is common in patients undergoing unicondylar knee replacement. To measure the geometry and morphology of these knees is to know whether a single unicondylar knee implant design is suitable for all patients, i.e. for patients with varus deformity and those without. The aim of this study was to identify any significant differences between normal and varus knees that may influence unicondylar implant design for the latter group. Methodology:. 56 patients (31 varus, 25 normal) were evaluated through CT imaging. Images were segmented to create 3D models and aligned to a tri-spherical plane (centres of spheres fitted to the femoral head and the medial and lateral flexion facets). 30 key co-ordinates were recorded per specimen to define the important axes, angles and shapes (e.g. spheres to define flexion and extension facet surfaces) that describe the femoral condylar geometry using in-house software. The points were then projected in sagittal, coronal and transverse planes. Standardised distance and angular measurements were then carried out between the points and the differences between the morphology of normal and varus knee summarised. For the varus knee group, trends were investigated that could be related to the magnitude of varus deformity. Results:. Several significant differences between normal and varus knees were found, but most of these were small differences unlikely to be clinically significant or have an influence on implant design. However, two strong trends were observed. Firstly, the version of the femoral neck was significantly less for patients with varus knees (mean difference 9°; p < 0.05). The second trend was a significant difference in the sagittal morphology of the medial condyle. The kink angle, the angle formed by the intersection of the circles fitted to the flexion and extension facet surfaces, and their centres (Figure 1) was either absent or small in normal knees (mean 1°). An absent kink angle occurs when the circle defining the flexion facet surface lies within or makes a tangent to the circle defining the extension facet. However, for varus knees, the mean kink angle was 9°, with positive correlation with the angle of varus deformity (Figure 2). Discussion:. Varus knees have a significantly larger kink angle than normal knees, influencing the relative positions of the flexion and extension facet spheres that define the medial condylar geometry, contributing to the commonly observed ‘flattening’ of the medial condyle in the sagittal plane. Varus knees are also associated with significantly less anteversion of the femoral neck. It has been shown that reduced femoral neck anteversion causes increased loading of the medial condyle [1], and our results support this finding. The data generated in this study will feed further biomechanical testing to investigate the influence of kink angle and femoral neck version on the kinematics and load distribution in the varus knee


Aims

Total knee arthroplasty (TKA) may provoke ankle symptoms. The aim of this study was to validate the impact of the preoperative mechanical tibiofemoral angle (mTFA), the talar tilt (TT) on ankle symptoms after TKA, and assess changes in the range of motion (ROM) of the subtalar joint, foot posture, and ankle laxity.

Methods

Patients who underwent TKA from September 2020 to September 2021 were prospectively included. Inclusion criteria were primary end-stage osteoarthritis (Kellgren-Lawrence stage IV) of the knee. Exclusion criteria were missed follow-up visit, post-traumatic pathologies of the foot, and neurological disorders. Radiological angles measured included the mTFA, hindfoot alignment view angle, and TT. The Foot Function Index (FFI) score was assessed. Gait analyses were conducted to measure mediolateral changes of the gait line and ankle laxity was tested using an ankle arthrometer. All parameters were acquired one week pre- and three months postoperatively.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 19 - 19
1 Jan 2004
Cobb J Henckel J Harris S Jakopec M Baena FRY Gomes M Davies B
Full Access

The Acrobot®, an active constraint “hands-on” robotic system, gives navigation cues to the surgeon, and also assists him in the surgery, using active software constraints if he tries to depart from the preoperative plan. It has just entered clinical trials. We report the first 5 cases. The Acrobot® system for precision total knee arthroplasty comprises the following components:. 1. A CT-based planning system. 2. The limb positioning system. 3. The Acrobot’s hardware components:. a gross positioning device with separate brakes and encoders, locked off for safety during the procedure,. a fully back-driveable low force robot, and. a force control handle on the robot close to the high-speed milling tool. 4. The Acrobot’s software which:. imports the preoperative plan,. allows anatomic registration. provides navigation,. physically assists the surgeon perform his plan. Each patient’s knee scores were monitored and postoperative CT scan was compared with the preoperative plan. Seven robot assisted arthroplasties have been performed. No significant complications have been encountered. The Knee and Womac Scores show that the procedure is safe and comparable to conventional surgery in the early postoperative period. The envelope of error on postoperative CT scans has been within the accuracy of the method of measurement, at < 1 mm and < 10 without the outliers which haunt every clinical series. The Acrobot® system for total knee arthroplasty has completed its preliminary trial satisfactorily. It provides a handson operation but with robotic levels of accuracy. It is suitable for conventional open surgery, but its real place will be in the arena of minimally invasive unicondylar knee arthroplasty, hip arthroplasty and resurfacing, and in the spine, where active constraint will prevent potentially dangerous surgical errors


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 581 - 581
1 Aug 2008
Briffa N Sadiq S Cobb J
Full Access

Introduction: A subjective observation suggests that a significant percentage of patients offered a TKR could benefit from a relatively more conservative, less invasive unicompartmental knee arthroplasty. We set out to challenge this hypothesis. Materials & Methods: 1147 TKRs were performed between 2002 and 2005 at Ravenscourt Park Hospital. 50 consecutive knee x-rays of patients who underwent a TKR were reviewed by three independent observers. Medial and lateral articular cartilage height, varus angulation, and femero-tibial anteroposterior and mediolateral translation were measured on antero-posterior and lateral weight bearing radiographs. Skyline views were analysed for patellofemoral disease. The most appropriate procedure according to local radiological criteria was recorded for all three observers. Unicompartmental arthroplasty was considered when the following criteria was met 1) anteromedial disease with preservation of posterior slope, 2) preservation of the tibial spines, 3) no anteroposte-rior or mediolateral translation, 4) normal tibiofemoral alignment and 5) preservation of patellofemoral joint. Osteophytes were disregarded. Tricompartmental disease merited a TKR while isolated patellofemoral (PFJ) disease considered for PFJ replacement. Patients were not formally examined. Preoperative Knee Society Scores (KSS) and WOMAC scores were noted. Results: The three observers indicated that 26 (52%), 21 (42%) and 22 (44%) patients respectively could potentially benefit from a unicompartmental arthroplasty given the right clinical setting. Consensus was reached for unicompartmental replacement in 16 (31.2%) and for TKR in 18 (36%) of cases. There was no correlation between the operation performed and operation proposed (42% ± 8) suggesting that the surgeon’s preference is a dominating factor. Interestingly within the proposed unicompartmental group Knee Society Scores were higher (100 ± 22 vs 71 ± 26) giving an indication to the disease severity. Conclusion: The clinical benefit and economic value of opting for a unicondylar knee arthroplasty when indicated is considerable. None the less it was only considered by a minority of surgeons who undertake knee arthroplasty


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 166 - 166
1 Mar 2008
Harman M Schmitt S Roessing S Banks S Scharf H Hodge WA
Full Access

There is renewed interest in unicondylar knee replacements (UKR) to meet the increasing demand for less invasive surgical procedures for knee arthroplasty. UKR survivorship exceeds 85% at 10 years, with unconstrained (round-on-flat) designs showing significantly better survivorship than conforming designs. However, round-on-flat articulation shave the potential for poor wear performance and more conforming, mobile-bearing UKR designs have been advocated. The purpose of this study was to evaluate the wear performance of unconstrained UKR polyethylene bearings retrieved at revision knee arthroplasty. Forty-two UKR (eight designs) were retrieved from 26 female and 16 male patients. Patient age averaged 73+10 (45–89) years and time in-situ averaged 7+4 (1–19) years. Revision reasons included loosening (45%), progressive osteoarthritis (17%), polyethylene wear (14%), instability (5%), and other (19%). Retrospective radiographic review of radiolucent lines and component alignment was completed. Polyethylene damage (severity score, 0–3) and location were measured using optical microscopy and digital image analysis. 81% of the polyethylene inserts had a concave deformation located on the central or posterior third of the articular surface, consistent with damage due to femoral component articulation. Abrasive damage on 29 (69%) inserts was consistent with impingement between the polyethylene and extra-articular cement or bone. There was delamination in the central region of 7 (17%) inserts and on the extreme posterior rim of 3 (7%) inserts. Severity score averaged 2.0+1.2 for abrasion and 0.5+1.0 for delamination. Radiographic component position was correlated with abrasive polyethylene damage. Despite initial tibiofemoral incongruity and concerns of high contact stress, round-on-flat UKR offers a durable knee arthroplasty. Delamination was infrequent and did not correlate with time in-situ. Rather, polyethylene cold flow increased the contact area during in-vivo function. Rigorous attention to cement technique and component position may reduce the incidence of abrasive damage on UKR polyethylene inserts


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 74 - 74
1 Aug 2013
Jaramaz B Picard F Gregori A
Full Access

NavioPFS™ unicondylar knee replacement (UKR) system combines CT-free planning and navigation with robotically assisted bone preparation. In the planning procedure, all relevant anatomic information is collected under navigation, either directly with the point probe or by kinematic manipulation. In addition to key anatomic landmarks and the maps of the articulating surfaces of the femur and tibia, kinematic assessment of the joint laxity is performed. Relative positions of femur and tibia are collected through the flexion/extension range, with the pressure applied to fully stretch the collateral ligament on the operative side. The planning procedure involves three stages: (1) the implant sizing and initial placement,(2) balancing of the gap on the operative side and (3) evaluating the contact points for the recorded flexion data and the planned placement of implants. In the gap balancing stage, the implants are repositioned until they allow for a positive gap, preferably uniform, throughout the entire range of flexion. UKR was planned and prepared on six cadaver knees with the help of NavioPFS system. All knees were normal without any signs of osteoarthritis. Two surgeons have performed medial UKR (4+2), and the bones were prepared using the NavioPFS handheld robotic tool. Postoperatively, we have re-used the data collected during the planning procedure to compare the kinematic (gap balancing) performance of the used implant with three different commercial implant designs. All implants were placed in the orientation recommended by the respective manufacturer, sized to best fit the original bone geometry, and repositioned optimally balance the gap curve through the entire flexion range, without any negative gaps (overlaps). Since these were nonarthritic cadaver knees, the intent was to restore the original preoperative varus/valgus in neutral (zero) flexion. The three implant designs demonstrated variable degree of capability to uniformly balance the knee gap over the entire range of flexion. The first implant (A) required a gap larger than 2 mm in one case out of six, the second (B) was capable of producing the positive gap curve under 2mm of gap in all six cases, and the third (C) required a gap larger than 2 mm in 3 (50%) of cases. All three designs exhibit the reduced gap space in mid (30°–90°) flexion. Despite the best attempts, the artificial implants do not fully replicate the healthy knee kinematics. This is manifested by increased tightness in the mid flexion. In order to balance the gap in mid flexion, additional laxity has to be allowed in full flexion, extension, or both. NavioPFS allows for patient specific planning that takes into account this information, only available intraoperatively. This kind of evaluation on a patient specific basis is a very important planning tool and it allows the insight on the implant performance in mid flexion, typically not available using conventional planning techniques. It can also help in improving kinematic performance of future implant designs


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 151 - 151
1 Mar 2010
Nellans KW Yoon RS Kim AD Jacobs M Geller JA Macaulay W
Full Access

Introduction: Ranked as the second most common cause of long-term disability amongst American adults, osteoarthritis (OA) affects well over 60 million Americans per year. OA is one of the major contributors to health care-related economic cost in the US, which is generally considered unacceptably high when compared other Western industrialized nations. Methods: Three hundred and thirty-five patients undergoing primary unilateral or bilateral total hip arthroplasty (THA), metal-on-metal hip resurfacing (MOMHR), total knee arthroplasty (TKA), or unicondylar knee arthroplasty (UKA) were offered voluntary participation in an one-on-one preoperative education session with a pre-operative educator. Length of stay (LOS) and in-patient costs was collected for patients who received individual pre-operative education. This was then compared to patients who chose not to participate in the education sessions using linear regression models. Results: Patients who chose to participate enjoyed a significantly shorter LOS than those who did not receive education, controlling for age, sex, type of procedure, and number of co-morbid conditions (3.1 ± 1.1 vs. 4.5 ± 4.7; p< 0.01). THA patients participating in the preoperative education program exhibited a calculated cost savings of $861 per case over non-educated patients (p=0.06), while TKA patients participating in the program exhibited a statistically significant savings of $1,144 per case (p=0.02). This translated into a cost savings of $84,351 for 93 THA patients and $93,493 for 74 TKA patients at our institution, accounting for the cost of the patient educator. Of higher significant impact on cost savings was the number of co-morbid conditions for both THA (p=0.01) and TKA (p=0.01) patients. If applied in the national setting, national cost savings projections for a mean 0.84 day reduction in LOS for educated THA patients estimated a savings of nearly $800 million; a mean 0.56 day reduction for preoperatively educated TKA translated into a projected savings of $1.1 billion on the national scale. Conclusion: Preoperative education in the setting of hip and knee arthroplasty is an important cost-savings tool for hospitals, Medicare and third party payers in this era of rising health care costs


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 150 - 150
1 Apr 2005
Ramakrishnan M Sundaram R Parkinson R
Full Access

Aims: To determine the kneeling ability in 3 groups of patients who have undergone either Unicondylar, Primary, or Revision knee arthroplasty. Methods: A questionnaire was designed to determine the kneeling ability of patients who have undergone knee arthroplasty surgery. The ‘Kneeling’ questionnaire along with a Western Ontario and MacMaster Osteoarthritis Index (WOMAC) questionnaire was sent to 191 patients of whom, 27 have had Unicondylar, 105 had Primary and 59 Revision knee arthroplasty. Results: The mean follow-up time for assessment for each of the 3 groups of patients were; Unicondylar = 3.32 years, Primary = 5.30 years and Revision = 5.06 years. The mean total WOMAC scores for the 3 groups were; Unicondylar = 13.96, Primary = 22.10, and Revision = 38.67. The percentage of patients who underwent knee arthroplasty that found it impossible to kneel were; Unicondylar = 18%, Primary = 36% and Revision = 66%. The commonest reasons why patients found kneeling difficult were; pain and stiffness around the knee prosthesis, fear of harming the prosthesis and sensory deficit around the knee. Visual Analogue Pain scores for kneeling in the 3 patient groups were, Unicondylar = 5.6, Primary = 7.12, Revision = 9.18. A minimum of 30% of patients in each of the 3 groups reported their daily lives were moderately-severely affected due to their difficulty in kneeling following knee arthroplasty. At least 60% of the patients in each group reported they would like to have better kneeling ability. Conclusion: Unicondylar knee arthroplasty patients have better WOMAC scores and find kneeling easier than patients who have undergone Primary knee arthroplasty (p< 0.01). The Primary group have better WOMAC scores and find kneeling easier than the Revision group (p< 0.001). Kneeling is considered important in patients who have undergone knee arthroplasty. Poor kneeling ability in patients may restrict their daily activities


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 318 - 318
1 Dec 2013
Gardner A Angibaud L Stroud N
Full Access

Introduction. Ideally, a patient receiving a unicondylar knee replacement will have fully functional anterior and posterior cruciate ligaments. When at least one of the cruciate ligaments is not fully functional, femoral and tibial implant contact position can potentially increase along the anterior-posterior (AP) axis. Where unicondylar implant wear testing typically uses AP resistance assuming fully functional cruciate ligaments, the authors used reduced AP resistance intended to simulate deficient cruciate ligaments. Methods. Optetrak Logic® Uni (Exactech Inc, Gainesville, FL USA) unicondylar test specimens featuring an all-UHMWPE tibial component and a cobalt chromium femoral component were used in this study. The system has a semi-constrained articular geometry. Testing was conducted at an independent testing facility (EndoLab GMBH, Thansau, Rosenheim, Germany). A four-station knee simulator was used (EndoLab knee simulator) with two unicondylar knee implants per station, giving a total of eight test specimens. Two different tibial fixation designs (keeled and peg) with identical articulating surfaces were tested. Tibial test specimens were 6 mm in thickness. Unloaded soak controls were stored in distilled water at 37°C. The test was conducted according to ISO 14243–1: 2009 [1]. Test specimens were immersed in calf serum (PAA GmBH, Cölbe, LOT B00111-5126) with a protein content of 20 g/l. Custom polyurethane molds allowed for individual component measurement. Per the ISO 14243-1, a 7% medial offset was incorporated into the set-up. The unicondylar knee implants were set at neutral position in extension. Tibial rotational restraint was 0.36 Nm/° and zero when the test specimen was within ± 6° of the reference position. This test was conducted with an AP resistance of 9.3N/mm to maximize AP displacement and simulate deficient cruciate ligaments. Typical unicondylar knee wear testing is conducted with an AP resistance of 44N/mm, which assumes functional cruciate ligaments. Results. Wear data was separated by component design (keeled and peg) as well as for medial and lateral placement [Table 1]. There was no significant difference between lateral components but there was for medial components. This difference could be due to the small sample size. Contact area of the UHMWPE tibial components was elliptical, with the longer portion along the AP axis. Mean wear rates were comparable to historical unicondylar knee systems tested at the same laboratory using the standard AP resistance (i.e., 44 N/mm). Discussion/Conclusion. This study demonstrated using an AP resistance 9.3 N/mm to simulate the presence of deficient cruciate ligaments in a unicondylar knee wear test produced similar wear rates and greater AP displacement when compared to testing using an AP resistance of 44 N/mm, which assumes functioning ligaments. This being said, design and material information about historical unicondylar knee systems tested are not known, so a direct comparison cannot be made. Performing unicondylar knee wear tests with reduced AP resistance could provide realistic wear information for devices implanted in patients without fully functioning cruciate ligaments


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 608 - 608
1 Oct 2010
Nancoo T Al-Obaydi WK Modi C Nicholson J Pereira G Rampurada A
Full Access

In the UK, surveillance for surgical site infection is mandatory for orthopaedic surgery. NHS trusts must participate for at least one surveillance period (3 months) every year in at least one of four categories:- hip replacement, knee replacement, hip hemiarthroplasty or open reduction of long bone fractures. Surgical site infections (SSIs) are defined as infections related to a surgical procedure that affects the surgical wound or deeper tissues handled during the procedure. Since mandatory surveillance began in 2004, rates of SSIs have markedly decreased. This is postulated to be secondary to increased early detection. Shorter postoperative stays and underestimation are also likely to be influential factors. We reviewed 150 consecutive lower limb arthroplasties performed at a district general hospital from July to September 2007. All inpatient data were collected as part of the Health Protection Agencies mandatory surveillance. We reviewed this data and notes for recorded evidence of infections or complications for minimum of one year after surgery. We reviewed computer records for recorded microbiological evidence of infection preoperatively and postoperatively. The operations performed during the surveillance period were:- 60 primary total knee replacements (TKRs), 37 primary hip replacements (THRs), 25 hip resurfacings, 15 unicondylar knee replacements, 3 patello-femoral joint replacements, 6 revision TKRs and 4 revision THRs. No SSI’s were detected during the mandatory surveillance period (i.e the inpatient stay, mean 5.61 days, Range 2–44 days). Two SSI’s (1.33%) were detected in our follow up period. Both were superficial wound infections. The first, a 53 year old hip resurfacing patient who was discharged 3 days postoperatively and developed Staphyloccocal infection 5 days later. The other was a 76 year old who underwent THR surgery, was discharged at day 6 and presented on day 12 with Pseudomonas wound infection. Both cases were initially diagnosed and treated successfully with oral antibiotic by GPs. One 61 year old patient who underwent hip resurfacing presented at day 62 with pain. X-rays showed loosening. Deep infection was suspected but hip aspirate, and inflammatory markers were negative. He is being monitored in the outpatient department. Our analysis also revealed that 3 patients had urinary tract infections (Coliforms on MSU) on the day of surgery and none have had postoperative complications. Intraoperative soft tissue samples for one patient who underwent one stage revision TKR grew Haemolytic Streptoccocus but there has been no evidence of postoperative complications. Other complications seen were THR dislocations (n=3) for reasons other than infection, 2 were revised. Persistent pain (n=2), common peroneal nerve palsy (n=1). We conclude that detection of SSI during inpatient stay is almost impossible. Mandatory surveillance seems excessive and a waste of resources


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 95 - 96
1 Mar 2006
Harman M Schmitt S Roessing S Banks S Scharf H Hodge W
Full Access

There is renewed interest in unicondylar knee replacements (UKR) to meet the increasing demand for less invasive surgical procedures for knee arthroplasty. UKR survivorship exceeds 85% at 10 years, with unconstrained (round-on-flat) designs showing significantly better survivorship than conforming designs. However, round-on-flat articulations have the potential for poor wear performance and more conforming, mobile-bearing UKR designs have been advocated. This study evaluates the wear performance of unconstrained UKR polyethylene bearings retrieved at revision knee arthroplasty. Forty-two UKR with fixed polyethylene tibial bearings were retrieved. Patient age and time in-situ averaged 73 (45–89) years and 7 (1–19) years, respectively. All knees had intact cruciate ligaments at index surgery. Revision reasons included loosening (45%), progressive arthritis (17%), polyethylene wear (17%), instability (5%), and other (17%). Retrospective radiographic review of radiolucent lines and component alignment was completed using Knee Society guidelines. Polyethylene articular damage size (% of articular surface area), location and damage mode incidence were measured using microscopy and digital image analysis. Damage area was centrally located and averaged 65%+22%. The largest damage areas consisted of abrasion (19%) and scratching (17%). Revision for loosening or wear was significantly correlated with greater damage area (Spearman Correlation, p=0.049). The incidence of scratching, pitting and abrasion each exceeded 70%, including 29 inserts with peripheral abrasive damage consistent with impingement between the polyethylene and extra-articular cement or bone. Anterior damage location and abrasion were significantly correlated with component position (p< 0.001). Concave surface deformation due to femoral component contact was externally rotated (24 inserts), consistent with tibial external rotation relative to the femoral component, neutrally aligned (11 inserts), internally rotated (4 inserts), and indeterminate (3 inserts). Despite initial tibiofemoral incongruity and concerns of high contact stress, round-on-flat UKR offers a durable knee arthroplasty. The relatively unconstrained tibiofemoral articulations allowed freedom of placement on the resected bone surfaces and a range of tibio-femoral rotation during activity, as demonstrated by the rotated concave surface deformations. Such deformation may reduce polyethylene contact stresses by increasing the tibio-femoral contact area. However, similar to retrieved mobile bearing UKR which show a 63% incidence of impingement, abrasive damage on these fixed bearing UKR has consequences for polyethylene debris generation and the transmission of shear forces to the bone-implant interface. Rigorous attention to conventional and minimally invasive surgical technique, including cement fixation and component position, is needed to reduce the incidence of abrasive polyethylene damage


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 59 - 59
1 Oct 2012
Schkommodau E Coigny F Findeisen C Hirschmann M Ballweg C Jürgens P Thoranaghatte R Hemm S Knobel B
Full Access

Background. Currently existing optical navigation systems have ergonomic disadvantages such as size, the “line of sight” problem and extended registration procedures. The operation room becomes crowded by additional installations and competitive supporting devices around the patient. These points reduce and limit the acceptance of navigation systems for further applications. But especially for surgical quality management, navigation systems have a high potential as objective measurement systems. Method. A miniaturised measuring and navigation system, which is directly fixed at the surgical tool, could overcome these limitations and fulfil the requirements demanded by current and future operation rooms. Minimising the distance between situ and camera promises an increased accuracy, a reduced “line of sight problem,” intuitive handling and one coordinate transformation (Tool2DRB) less. However, such a setting reduces the navigation working space available, needs a sterile system, a new marker design and special requirements for the cameras. The developed prototypes were tested in vitro using Synbones™ and ex vivo at anatomical specimen. Following surgical pilot applications were defined and considered during the studies: maxillofacial restoration osteotomy, hip replacement and unicondylar knee replacements (UKR). Special emphasis was placed on measured and recorded accuracy and miniaturised hardware. Results. Several miniaturised measuring system prototypes with high resolution cameras mounted directly onto a surgical instrument have been developed and tested. One prototype includes a laser device which is used in combination with the cameras to register 3D surfaces like the rotational centre of an acetabular cup from a prosthetic hip joint. Other prototypes demonstrate the miniaturising aspect of this development and their ergonomic advantages. Corresponding algorithm and software developments include calibration, marker identification, network components and surgical planning modules. Hard and software components have been tested for UKR application in an ex vivo study. Clinical trials for maxillofacial restoration osteotomy are prepared at the University Hospital Basel. The accuracy of the presented systems was evaluated in vitro with two setups. After intrinsic and extrinsic camera calibration with a 3D calibration specimen, the accuracy (RMS) of a single point of the 3D point coordinates of the calibration specimen could be determined with 0,020 mm in z-axis and 0,010 mm in x/y-axis. In another setup the accuracy was measured in 3D with a fixed camera system and two markers rigidly fixed together. The marker system was moved around working space. The repeat accuracy of the distances between the two markers was 0,025 mm (RMS). Discussion. The total development of the miniaturised measuring system, consisting of a video system, an optional laser scanner, calibration, image processing algorithms and planning modules was successful. The current prototype has proved to be accurate and usable. Users (surgeons) and suppliers of surgical implants, who have been exposed to the system, have expressed their keen interest, as it opens up new applications and fulfils their needs for improved ergonomics and smarter, cost reducing work flows. But of course there is still potential for improvements. In the next iteration of the development process, the usability and accuracy of the system could still be improved. The currently used optics limit the possible accuracy because the aperture of F = 2.8 is too large for photogrammetric applications and its optics distortions are too large. Therefore it will be exchanged by an optimised solution. Another optimisation target is the camera electronics. The currently used ones cannot be synchronised, which limits the usability, respectively reduces the accuracy, if it is moved during a measurement shot


Bone & Joint Open
Vol. 4, Issue 8 | Pages 621 - 627
22 Aug 2023
Fishley WG Paice S Iqbal H Mowat S Kalson NS Reed M Partington P Petheram TG

Aims

The rate of day-case total knee arthroplasty (TKA) in the UK is currently approximately 0.5%. Reducing length of stay allows orthopaedic providers to improve efficiency, increase operative throughput, and tackle the rising demand for joint arthroplasty surgery and the COVID-19-related backlog. Here, we report safe delivery of day-case TKA in an NHS trust via inpatient wards with no additional resources.

Methods

Day-case TKAs, defined as patients discharged on the same calendar day as surgery, were retrospectively reviewed with a minimum follow-up of six months. Analysis of hospital and primary care records was performed to determine readmission and reattendance rates. Telephone interviews were conducted to determine patient satisfaction.


Bone & Joint Research
Vol. 11, Issue 11 | Pages 826 - 834
17 Nov 2022
Kawai T Nishitani K Okuzu Y Goto K Kuroda Y Kuriyama S Nakamura S Matsuda S

Aims

The preventive effects of bisphosphonates on articular cartilage in non-arthritic joints are unclear. This study aimed to investigate the effects of oral bisphosphonates on the rate of joint space narrowing in the non-arthritic hip.

Methods

We retrospectively reviewed standing whole-leg radiographs from patients who underwent knee arthroplasties from 2012 to 2020 at our institute. Patients with previous hip surgery, Kellgren–Lawrence grade ≥ II hip osteoarthritis, hip dysplasia, or rheumatoid arthritis were excluded. The rate of hip joint space narrowing was measured in 398 patients (796 hips), and the effects of the use of bisphosphonates were examined using the multivariate regression model and the propensity score matching (1:2) model.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 178 - 179
1 Jul 2002
Romagnoli S
Full Access

Mini-invasive technique relies on mini skin incision: 5–8 cm long, no tourniquet, no Hoffa’s fat pad, and patellar tendon stress. The incision has to allow the inspection in flexion of the contralateral compartments and the inspection–treatment of the patella in extension (osteophyte removal). During the procedure it is mandatory to check the proper position of the prosthesis components. In case of varus or valgus degeneration, we can perform a parapatellar medial or lateral minimally invasive approach. In my own experience, from 1984 to 1996, I performed 1067 unicondylar knee replacements (UKR) by the traditional approach. From 1997 to 2001, I operated using the mini-invasive technique on 1091 UKRs. The comparison between these two groups of patients has shown less postoperative pain, quicker recovery and shorter hospitalisation time in the mini-invasive group. There were no differences between groups for shortterm results. For long-term results, in March 2001 we evaluated 112 patients with a UKR (AllegrettoTM – Sulzer Medica) and a relative standard approach with 8–10 years follow-up. These implants were performed between November 1990 and March 1993, in 105 cases in the medial compartment and in seven cases in the lateral. The preoperative indications were: 98 arthritis, four HTO sequelae, four condyle osteonecrosis, three post-traumatic sequelae, three UKR revision, in eight cases the ACL had degenerated. At follow-up, seven patients were dead, 0 were lost, three revised and two submitted to an arthroscopy (lateral meniscus degeneration). The cause of three revisions (2.5%) was one femoro-patellar degeneration and two aseptic loosening, no septic revision. We think that these survival rates cannot be modified by a minimally invasive technique. Technically, the mini skin incision needs the observance of some basic rules. A preoperative plan is mandatory to address the thickness and slope of bone cuts as well as prosthesis size. Prosthesis instruments and hardware must be designed to be suitable for minimal bone exposure. With experience we can utilise free hand surgical technique; this technique reduces the operative time and invasiveness. Skin landmarks have to be easily recognised on the anatomical region to preserve the soft tissue around the approach. Skin incision is para-patellar medial or lateral. It starts proximally 1 cm below the superior margin of the patella. It ends distally within 1 cm below the joint line. To expose the femoral condyle it is not necessary to dislocate the patella, but it should be relatively subluxed. When the prosthesis is fitted, the mini-incision allows for a reliable check of stability, alignment, and prosthesis component relation. The mini-invasive technique permits faster surgery and is particularly suitable for one-stage bilateral UKR procedures and patients with systemic heart and vascular disease. Concerns may arise: the learning curve. The mini para-patella skin incision, among the superior and inferior geniculata arteries, allows a safe and straight approach to the knee


Bone & Joint Research
Vol. 11, Issue 2 | Pages 91 - 101
1 Feb 2022
Munford MJ Stoddart JC Liddle AD Cobb JP Jeffers JRT

Aims

Unicompartmental and total knee arthroplasty (UKA and TKA) are successful treatments for osteoarthritis, but the solid metal implants disrupt the natural distribution of stress and strain which can lead to bone loss over time. This generates problems if the implant needs to be revised. This study investigates whether titanium lattice UKA and TKA implants can maintain natural load transfer in the proximal tibia.

Methods

In a cadaveric model, UKA and TKA procedures were performed on eight fresh-frozen knee specimens, using conventional (solid) and titanium lattice tibial implants. Stress at the bone-implant interfaces were measured and compared to the native knee.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1555 - 1560
4 Oct 2021
Phillips JRA Tucker K

Aims

Knee arthroplasty surgery is a highly effective treatment for arthritis and disorders of the knee. There are a wide variety of implant brands and types of knee arthroplasty available to surgeons. As a result of a number of highly publicized failures, arthroplasty surgery is highly regulated in the UK and many other countries through national registries, introduced to monitor implant performance, surgeons, and hospitals. With time, the options available within many brand portfolios have grown, with alternative tibial or femoral components, tibial insert materials, or shapes and patella resurfacings. In this study we have investigated the effect of the expansion of implant brand portfolios and where there may be a lack of transparency around a brand name. We also aimed to establish the potential numbers of compatible implant construct combinations.

Methods

Hypothetical implant brand portfolios were proposed, and the number of compatible implant construct combinations was calculated.


Bone & Joint 360
Vol. 10, Issue 4 | Pages 49 - 51
1 Aug 2021
Evans JT Welch M Whitehouse MR


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1449 - 1456
1 Sep 2021
Kazarian GS Lieberman EG Hansen EJ Nunley RM Barrack RL

Aims

The goal of the current systematic review was to assess the impact of implant placement accuracy on outcomes following total knee arthroplasty (TKA).

Methods

A systematic review was performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines using the Ovid Medline, Embase, Cochrane Central, and Web of Science databases in order to assess the impact of the patient-reported outcomes measures (PROMs) and implant placement accuracy on outcomes following TKA. Studies assessing the impact of implant alignment, rotation, size, overhang, or condylar offset were included. Study quality was assessed, evidence was graded (one-star: no evidence, two-star: limited evidence, three-star: moderate evidence, four-star: strong evidence), and recommendations were made based on the available evidence.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 619 - 626
1 Apr 2021
Tolk JJ Janssen RPA Haanstra TM van der Steen MC Bierma-Zeinstra SMA Reijman M

Aims

Meeting preoperative expectations is known to be of major influence on postoperative satisfaction after total knee arthroplasty (TKA). Improved management of expectation, resulting in more realistic expectations can potentially lead to higher postoperative satisfaction. The objective of this study was to assess the effect of an additional preoperative education module, addressing realistic expectations for long-term functional recovery, on postoperative satisfaction and expectation fulfilment.

Methods

In total, 204 primary TKA patients with osteoarthritis were enrolled in this randomized controlled trial (RCT). Patients were allocated to either usual preoperative education (control group) or usual education plus an additional module on realistic expectations (intervention group). Primary outcome was being very satisfied (numerical rating scale for satisfaction ≥ 8) with the treatment result at 12 months' follow-up. Other outcomes were change in preoperative expectations and postoperative expectation fulfilment.


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 589 - 596
1 Mar 2021
Amin N Kraft J Fishlock A White A Holton C Kinsey S Feltbower R James B

Aims

Osteonecrosis (ON) can cause considerable morbidity in young people who undergo treatment for acute lymphoblastic leukaemia (ALL). The aims of this study were to determine the operations undertaken for ON in this population in the UK, along with the timing of these operations and any sequential procedures that are used in different joints. We also explored the outcomes of those patients treated by core decompression (CD), and compared this with conservative management, in both the pre- or post-collapse stages of ON.

Methods

UK treatment centres were contacted to obtain details regarding surgical interventions and long-term outcomes for patients who were treated for ALL and who developed ON in UKALL 2003 (the national leukaemia study which recruited patients aged 1 to 24 years at diagnosis of ALL between 2003 and 2011). Imaging of patients with ON affecting the femoral head was requested and was used to score all lesions, with subsequent imaging used to determine the final grade. Kaplan-Meier failure time plots were used to compare the use of CD with non surgical management.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 24 - 33
1 Jan 2019
Kayani B Konan S Tahmassebi J Rowan FE Haddad FS

Aims

The objectives of this study were to compare postoperative pain, analgesia requirements, inpatient functional rehabilitation, time to hospital discharge, and complications in patients undergoing conventional jig-based unicompartmental knee arthroplasty (UKA) versus robotic-arm assisted UKA.

Patients and Methods

This prospective cohort study included 146 patients with symptomatic medial compartment knee osteoarthritis undergoing primary UKA performed by a single surgeon. This included 73 consecutive patients undergoing conventional jig-based mobile bearing UKA, followed by 73 consecutive patients receiving robotic-arm assisted fixed bearing UKA. All surgical procedures were performed using the standard medial parapatellar approach for UKA, and all patients underwent the same postoperative rehabilitation programme. Postoperative pain scores on the numerical rating scale and opiate analgesia consumption were recorded until discharge. Time to attainment of predefined functional rehabilitation outcomes, hospital discharge, and postoperative complications were recorded by independent observers.