Advertisement for orthosearch.org.uk
Results 1 - 89 of 89
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 172 - 172
1 Dec 2013
Simon P Diaz M Schwartz D Santoni B Frankle M
Full Access

Introduction:. The complex 3D geometry of the scapula and the variability among individuals makes it difficult to precisely quantify its morphometric features. Recently, the scapular neck has been recognized as an important morphometric parameter particularly due to the role it plays in scapular notching, which occurs when the humeral component of a reverse shoulder arthroplasty (RSA) prosthesis engages the posterior column of the scapula causing mechanical impingement and osseous wear. Prosthetic design and positioning of the glenoid component have been accepted as two major factors associated with the onset of notching in the RSA patient population. The present image-based study aimed to develop an objective 3D approach of measuring scapular neck, which when measured pre-operatively, may identify individuals at risk for notching. Materials and Methods:. A group of 81 subjects (41 M, 69.7 ± 8.9 yrs.; 40 F, 70.9 ± 8.1 yrs.) treated with RSA were evaluated in this study. The 3D point-cloud of the scapular geometry was obtained from pre-operative computed tomography (CT) scans and rendered in Mimics. Subsequently, a subject-specific glenoid coordinate system was established, using the extracted glenoid surface of each scapula as a coordinate reference. The principal component analysis approach was used to establish three orthogonal coordinate axes in the geometric center of the glenoid. Utilization of glenoid-specific reference planes (glenoid, major axis, and minor axis plane) were selected in order to remove subjectivity in assessing “true” anterior/posterior and profile views of the scapula. The scapular neck length was defined as the orthogonal distance between the glenoid surface and the point on the posterior column with the significant change of curvature (Fig. 1). In addition, the angle between the glenoid plane, area center of the glenoid, and the point of significant change of the curvature were assessed (Fig. 2). This new parameter was developed to serve as a predictive critical value for the occurrence of notching. The incidence of notching increases as the value of the notching angle decreases. In order to evaluate relationships between glenoid and scapular neck, the glenoid width and height was also measured at the glenoid plane. Results:. Glenoid neck length and notching angle within the population were normally distributed with mean values of 7.8 ± 2.3 mm and 19.6 ± 4.8°, respectively (Fig. 3). No gender difference was found (p = 0.676). In one subject, a glenoid neck length of less than 1 mm was measured with the notching angle less than 2.5°. No association between glenoid neck length and glenoid size were identified (vs. glen. height r. 2. = 0.001, and vs. glen. width r. 2. = 0.05). Conclusion:. The present study reported on the scapular neck length and notching angle as measureable morphometric parameters that follow a normal distribution throughout the population and that are not correlated to the subject's glenoid size. Pre-operative acquisition of these novel and unique CT-based measurements may promote more appropriate RSA prosthesis selection to account for subject-specific anatomy in an effort to avoid scapular notching. Inferior placement of a baseplate or lateralization of glenoid component center of rotation (either biologically or mechanically) both serves to theoretically increase the notching angle


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims. This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA). Methods. From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery. Results. There were no significant differences in demographic data and preoperative characteristics between the two groups. Both groups showed significant improvements in patient-reported outcome measures (visual analogue scale for pain, visual analogue scale for function, American Shoulder and Elbow Surgeons, Constant, and Simple Shoulder Test scores) from preoperative to final assessment (p < 0.001). However, AGB showed no additional benefit. Notably, within range of motion, Group B showed significant postoperative decrease in both external rotation and internal rotation, unlike Group A (p = 0.028 and 0.003, respectively). Both groups demonstrated a significant correction of superior-inclination after surgery, while patients in Group B exhibited a significant decrease in LHO postoperatively (p = 0.001). Regarding complications, Group A experienced more acromial stress fractures (3 cases; 12.5%), whereas Group B had a higher occurrence of scapular notching (24 cases; 33.3%) (p = 0.008). Conclusion. Both eccentric reaming with STB and off-axis reaming with AGB are effective methods for addressing superior glenoid wear in RSA, leading to improved clinical outcomes. However, it is important to be aware of the potential risks associated with eccentric reaming, which include excessive bone loss leading to reduced rotation and scapular notching. Cite this article: Bone Joint J 2024;106-B(3):268–276


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 91 - 96
1 Jan 2022
Modi A Haque A Deore V Singh HP Pandey R

Aims

Long-term outcomes following the use of human dermal allografts in the treatment of symptomatic irreparable rotator cuff tears are not known. The aim of this study was to evaluate these outcomes, and to investigate whether this would be a good form of treatment in young patients in whom a reverse shoulder arthroplasty should ideally be avoided.

Methods

This prospective study included 47 shoulders in 45 patients who underwent an open reconstruction of the rotator cuff using an interposition GraftJacket allograft to bridge irreparable cuff tears, between January 2007 and November 2011. The Oxford Shoulder Score (OSS), pain score, and range of motion (ROM) were recorded preoperatively and at one year and a mean of 9.1 years (7.0 to 12.5) postoperatively.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1189 - 1195
1 Nov 2023
Kim JS Kim SH Kim SC Park JH Kim HG Lee SM Yoo JC

Aims. The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes. Methods. This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group). Results. Perforation of the vault of the glenoid (p = 0.018) and size mismatch in height (p < 0.001) and width (p = 0.013) were significantly more frequent in the ST group than in the SM group. There was no significant difference in the clinical scores and ROM in the two groups, two years postoperatively (all p > 0.05). In subgroup analysis, the VP group had significantly less inferior overhang (p = 0.009), more scapular notching (p = 0.018), and more size mismatch in height (p < 0.001) and width (p = 0.025) than the VNP group. Conclusion. In Asian patients with a small glenoid, using a 29.5 mm small baseplate at the time of RSA was more effective in reducing size mismatch between the glenoid and the baseplate, decreasing the incidence of perforation of the glenoid vault, and achieving optimal positioning of the baseplate compared with the use of a 33.8 mm standard baseplate. However, longer follow-up is required to assess the impact of these findings on the clinical outcomes. Cite this article: Bone Joint J 2023;105-B(11):1189–1195


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 957 - 963
1 Sep 2024
Baek CH Kim JG Kim BT

Aims. Favourable short-term outcomes have been reported following latissimus dorsi tendon transfer for patients with an irreparable subscapularis (SSC) tendon tear. The aim of this study was to investigate the long-term outcomes of this transfer in these patients. Methods. This was a retrospective study involving 30 patients with an irreparable SSC tear and those with a SSC tear combined with a reparable supraspinatus tear, who underwent a latissimus dorsi tendon transfer. Clinical scores and active range of motion (aROM), SSC-specific physical examination and the rate of return to work were assessed. Radiological assessment included recording the acromiohumeral distance (AHD), the Hamada grade of cuff tear arthropathy and the integrity of the transferred tendon. Statistical analysis compared preoperative, short-term (two years), and final follow-up at a mean of 8.7 years (7 to 10). Results. There were significant improvements in clinical scores, in the range and strength of internal rotation and aROM compared with the preoperative values in the 26 patients (87%) who were available for long-term follow-up. These improvements were maintained between short- and long-term follow-ups. Although there was a decreased mean AHD of 7.3 mm (SD 1.5) and an increased mean Hamada grade of 1.7 (SD 0.5) at final follow-up, the rate of progression of cuff tear arthropathy remained low-grade. Comparison between the isolated SSC and combined SSC and reparable supraspinatus tear groups showed no significant differences. At final follow-up, one patient (3.8%) had undergone revision surgery to a reverse shoulder arthroplasty (RSA). No neurological complications were associated with the procedure. Conclusion. Latissimus dorsi transfer for an irreparable SSC tendon tear resulted in a significant clinical improvement, particularly in pain, range and strength of internal rotation and aROM, which were maintained over a mean of 8.7 years following surgery. Given that this was a long-term outcome study, there was a low-grade progression in the rate of cuff tear arthropathy. Thus, the long-term clinical efficacy of latissimus dorsi tendon transfer in patients with irreparable SSC was confirmed as a joint-preserving procedure for these patients, suggesting it as an effective alternative to RSA in young, active patients without degenerative changes of the glenohumeral joint. Cite this article: Bone Joint J 2024;106-B(9):957–963


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 461 - 469
1 Apr 2019
Lädermann A Schwitzguebel AJ Edwards TB Godeneche A Favard L Walch G Sirveaux F Boileau P Gerber C

Aims. The aim of this study was to report the outcomes of different treatment options for glenoid loosening following reverse shoulder arthroplasty (RSA) at a minimum follow-up of two years. Patients and Methods. We retrospectively studied the records of 79 patients (19 men, 60 women; 84 shoulders) aged 70.4 years (21 to 87) treated for aseptic loosening of the glenosphere following RSA. Clinical evaluation included pre- and post-treatment active anterior elevation (AAE), external rotation, and Constant score. Results. From the original cohort, 29 shoulders (35%) were treated conservatively, 27 shoulders (32%) were revised by revision of the glenosphere, and 28 shoulders (33%) were converted to hemiarthroplasty. At last follow-up, conservative treatment and glenoid revision significantly improved AAE, total Constant score, and pain, while hemiarthroplasty did not improve range of movement or clinical scores. Multivariable analysis confirmed that conservative treatment and glenoid revision achieved similar improvements in pain (glenoid revision vs conservative, beta 0.44; p = 0.834) but that outcomes were significantly worse following hemiarthroplasty (beta -5.00; p = 0.029). Conclusion. When possible, glenoid loosening after RSA should first be treated conservatively, then by glenosphere revision if necessary, and last by salvage hemiarthroplasty. Cite this article: Bone Joint J 2019;101-B:461–469


Bone & Joint Open
Vol. 1, Issue 12 | Pages 731 - 736
1 Dec 2020
Packer TW Sabharwal S Griffiths D Reilly P

Aims. The purpose of this study was to evaluate the cost of reverse shoulder arthroplasty (RSA) for patients with a proximal humerus fracture, using time-driven activity based costing (TDABC), and to compare treatment costs with reimbursement under the Healthcare Resource Groups (HRGs). Methods. TDABC analysis based on the principles outlined by Kaplan and a clinical pathway that has previously been validated for this institution was used. Staffing cost, consumables, implants, and overheads were updated to reflect 2019/2020 costs. This was compared with the HRG reimbursements. Results. The mean cost of a RSA is £7,007.46 (£6,130.67 to £8,824.67). Implants and staffing costs were the primary cost drivers, with implants (£2,824.80) making up 40% of the costs. Staffing costs made up £1,367.78 (19%) of overall costs. The total tariff, accounting for market force factors and high comorbidities, reimburses £4,629. If maximum cost and minimum reimbursement is applied the losses to the trust are £4,828.67. Conclusion. RSA may be an effective and appropriate surgical option in the treatment of proximal humerus fractures; however, a cost analysis at our centre has demonstrated the financial burden of this surgery. Given its increasing use in trauma, there is a need to work towards generating an HRG that adequately reimburses providers. Cite this article: Bone Jt Open 2020;1-12:731–736


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1609 - 1617
1 Dec 2018
Malhas AM Granville-Chapman J Robinson PM Brookes-Fazakerley S Walton M Monga P Bale S Trail I

Aims. We present our experience of using a metal-backed prosthesis and autologous bone graft to treat gross glenoid bone deficiency. Patients and Methods. A prospective cohort study of the first 45 shoulder arthroplasties using the SMR Axioma Trabecular Titanium (TT) metal-backed glenoid with autologous bone graft. Between May 2013 and December 2014, 45 shoulder arthroplasties were carried out in 44 patients with a mean age of 64 years (35 to 89). The indications were 23 complex primary arthroplasties, 12 to revise a hemiarthroplasty or resurfacing, five for aseptic loosening of the glenoid, and five for infection. Results. Of the 45 patients, 16 had anatomical shoulder arthroplasties (ASA) and 29 had reverse shoulder arthroplasties (RSA). Postoperatively, 43/45 patients had a CT scan. In 41 of 43 patients (95%), the glenoid peg achieved > 50% integration. In 40 of 43 cases (93%), the graft was fully or partially integrated. There were seven revisions (16%) but only four (9%) required a change of baseplate. Four (25%) of the 16 ASAs were revised for instability or cuff failure. At two-year radiological follow-up, five of the 41 cases (11%) showed some evidence of lucent lines. Conclusion. The use of a metal baseplate with a trabecular titanium surface in conjunction with autologous bone graft is a reliable method of addressing glenoid bone defects in primary and revision RSA setting in the short term. ASAs have a higher rate of complications with this technique


Bone & Joint Research
Vol. 8, Issue 8 | Pages 357 - 366
1 Aug 2019
Lädermann A Tay E Collin P Piotton S Chiu C Michelet A Charbonnier C

Objectives. To date, no study has considered the impact of acromial morphology on shoulder range of movement (ROM). The purpose of our study was to evaluate the effects of lateralization of the centre of rotation (COR) and neck-shaft angle (NSA) on shoulder ROM after reverse shoulder arthroplasty (RSA) in patients with different scapular morphologies. Methods. 3D computer models were constructed from CT scans of 12 patients with a critical shoulder angle (CSA) of 25°, 30°, 35°, and 40°. For each model, shoulder ROM was evaluated at a NSA of 135° and 145°, and lateralization of 0 mm, 5 mm, and 10 mm for seven standardized movements: glenohumeral abduction, adduction, forward flexion, extension, internal rotation with the arm at 90° of abduction, as well as external rotation with the arm at 10° and 90° of abduction. Results. CSA did not seem to influence ROM in any of the models, but greater lateralization achieved greater ROM for all movements in all configurations. Internal and external rotation at 90° of abduction were impossible in most configurations, except in models with a CSA of 25°. Conclusion. Postoperative ROM following RSA depends on multiple patient and surgical factors. This study, based on computer simulation, suggests that CSA has no influence on ROM after RSA, while lateralization increases ROM in all configurations. Furthermore, increasing subacromial space is important to grant sufficient rotation at 90° of abduction. In summary, increased lateralization of the COR and increased subacromial space improve ROM in all CSA configurations. Cite this article: A. Lädermann, E. Tay, P. Collin, S. Piotton, C-H Chiu, A. Michelet, C. Charbonnier. Effect of critical shoulder angle, glenoid lateralization, and humeral inclination on range of movement in reverse shoulder arthroplasty. Bone Joint Res 2019;8:378–386. DOI: 10.1302/2046-3758.88.BJR-2018-0293.R1


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 964 - 970
1 May 2021
Ling DI Schneider B Ode G Lai EY Gulotta LV

Aims. To investigate the impact of the Charlson and Elixhauser comorbidity indices on patient-reported outcomes measures (PROMs) following shoulder arthroplasty. Methods. Patients undergoing total shoulder arthroplasty (TSA), reverse shoulder arthroplasty (RSA), or hemiarthroplasty (HA) from 2016 to 2018 were identified, along with the Charlson and Elixhauser comorbidities listed as their secondary diagnoses in the electronic medical records. Patients were matched to our institution’s registry to obtain their PROMs, including shoulder-specific (American Shoulder and Elbow Society (ASES) and Shoulder Activity Scale (SAS)) and general health scales (12-Item Short Form Survey (SF-12) and Patient-Reported Outcomes Measurement Information System-Pain Interference). Linear regression models adjusting for age and sex were used to evaluate the association between increasing number of comorbidities and PROM scores. A total of 1,817 shoulder arthroplasties were performed: 1,017 (56%) TSA, 726 (40%) RSA, and 74 (4%) HA. The mean age was 67 years (SD 10), and 936 (52%) of the patients were female. Results. The most common comorbidities were obesity (1,256, 69%) and hypertension (990, 55%). Patients with more comorbidities had lower ASES and SAS scores at baseline (p < 0.001). Elixhauser comorbidities continued to negatively impact ASES and SAS scores at one year (p = 0.002) and two-year follow-up (p = 0.002). Patients with more comorbidities reported greater pain interference on PROMIS at baseline (p = 0.007), but not at two years. Higher number of Charlson comorbidities were associated with lower scores on the SF-12 mental component at baseline (p < 0.001) and two years (p = 0.020). Higher number of Elixhauser comorbidities were associated with lower SF-12 physical component scores at baseline (p < 0.001) and two years (p = 0.004). Conclusion. Higher number of comorbidities was associated with lower baseline scores and worse outcomes on both shoulder-specific and general health PROMs. The presence of specific comorbidities may be used during shared decision-making to manage expectations for patients undergoing shoulder arthroplasty. Cite this article: Bone Joint J 2021;103-B(5):964–970


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1555 - 1559
1 Nov 2020
Sebastia-Forcada E Lizaur-Utrilla A Mahiques-Segura G Ruiz-Lozano M Lopez-Prats FA Alonso-Montero C

Aims. The purpose of this study was to determine whether there were long-term differences in outcomes of reverse shoulder arthroplasty (RSA) undertaken for acute proximal humeral fracture versus rotator cuff deficiency with a minimum follow-up of five years. Methods. This was a prospective cohort study comparing 67 patients with acute complex proximal humeral fracture and 64 patients with irreparable rotator cuff deficiency who underwent primary RSA. In the fracture group, there were 52 (77.6%) females and 15 (22.4%) males, with a mean age of 73.5 years (51 to 85), while in the arthropathy group, there were 43 (67.1%) females and 21 (32.9%) males, with a mean age of 70.6 years (50 to 84). Patients were assessed by the Constant score, University of California Los Angeles shoulder score (UCLA), short version of the Disability of the Arm Shoulder and Hand score (QuickDASH), and visual analogue scales (VAS) for pain and satisfaction. Radiological evaluation was also performed. Results. Mean follow-up was 8.4 years (5 to 11). There were no significant differences in mean absolute (p = 0.125) or adjusted (p = 0.569) Constant, UCLA (p = 0.088), QuickDASH (p = 0.135), VAS-pain (p = 0.062), or range of movement at the final follow-up. However, patient satisfaction was significantly lower in the fracture group (p = 0.002). The complication rate was 1.5% (one patient) versus 9.3% (six patients), and the revision rate was 1.5% (one patient) versus 7.8% (five patients) in the fracture and arthropathy groups, respectively. The ten-year arthroplasty survival was not significantly different (p = 0.221). Conclusion. RSA may be used not only for patients with irreparable rotator cuff deficiencies, but also for those with acute complex proximal humeral fractures. We found that RSA provided similar functional outcomes and a low revision rate for both indications at long-term. However, satisfaction is lower in patients with an acute fracture. Cite this article: Bone Joint J 2020;102-B(11):1555–1559


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 63 - 67
1 Jan 2019
Erickson BJ Ling D Wong A Eno JJ Dines JS Dines DM Gulotta LV

Aims. The number of rotator cuff repairs that are undertaken is increasing. Reverse shoulder arthroplasty (RSA) is the procedure of choice for patients with rotator cuff arthropathy. We sought to determine whether patients who underwent rotator cuff repair and subsequent RSA had different outcomes compared with a matched control group who underwent RSA without a previous rotator cuff repair. Patients and Methods. All patients with a history of rotator cuff repair who underwent RSA between 2000 and 2015 with a minimum follow-up of two years were eligible for inclusion as the study group. Outcomes, including the American Shoulder and Elbow Surgeons (ASES) scores, were compared with a matched control group of patients who underwent RSA without having previously undergone rotator cuff repair. Results. The study group included 45 patients. Their mean age was 69 years (. sd. 8.6) and 27 patients (60%) were women. The mean ASES score improved from 43.1 to 76.6 two years postoperatively, and to 66.9 five years postoperatively. There was no significant difference between the outcomes at two years in the two groups (all p ≥ 0.05), although there was significantly more improvement in ASES scores in the control group (44.5 vs 33.4; p = 0.01). However, there was no significant difference between ASES scores at two and five years when baseline ASES scores were matched in the two groups (p = 0.42 at two years; p = 0.35 at five years). Conclusion. Significant improvements in ASES scores were seen following RSA in patients who had previously undergone rotator cuff repair. They had higher baseline ASES scores than those who had not previously undergone this surgery. However, there was no significant difference in outcomes between the two groups, two years postoperatively. Previous rotator cuff repair does not appear to affect the early outcome after RSA adversely


Abstract. Reverse shoulder arthroplasty (RSA) is being increasingly used for complex, displaced fractures of the proximal humerus. The main goal of the current study was to evaluate the functional and radiographic results after primary RSA of three or four-part fractures of the proximal humerus in elderly patients. Between 2012 and 2020, 70 consecutive patients with a recent three- or four-part fracture of the proximal humerus were treated with an RSA. There were 41 women and 29 men, with a mean age of 76 years. The dominant arm was involved in 42 patients (60%). All surgeries were carried out within 21 days. Displaced three-part fracture sustained in 16 patients, 24 had fracture dislocation and 30 sustained a four-part fracture of the proximal humerus. Patients were followed up for a mean of 26 months. The mean postoperative OSS at the end of the follow-up period was 32.4. The mean DASH score was 44.3. Tuberosity non-union occurred in 18 patients (12.6%), malunion in 7 patients (4.9%), heterotopic ossification in 4 patients (2.8%) and scapular notching in one patient. Anatomical reconstruction was achieved in 25 patients (17.5%), the influence of greater tuberosity healing on shoulder function could not be demonstrated. Heterotopic ossification seems to affect OSS and QDASH, we found statistically significant relation between HO and clinical outcomes. Patients with heterotopic ossification had significantly lower postoperative scores on DASH and OSS (P = .0527). Despite expecting good functional outcome with low complication rate after RSA, the functional outcome was irrespective of healing of the tuberosities


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 30 - 30
1 Dec 2022
Lohre R Lobo A Bois A Pollock J Lapner P Athwal G Goel D
Full Access

Glenoid baseplate orientation in reverse shoulder arthroplasty (RSA) influences clinical outcomes, complications, and failure rates. Novel technologies have been produced to decrease performance heterogeneity of low and high-volume surgeons. This study aimed to determine novice and experienced shoulder surgeon's ability to accurately characterise glenoid component orientation in an intra-operative scenario. Glenoid baseplates were implanted in eight fresh frozen cadavers by novice surgical trainees. Glenoid baseplate version, inclination, augment rotation, and superior-inferior centre of rotation (COR) offset were then measured using in-person visual assessments by novice and experienced shoulder surgeons immediately after implantation. Glenoid orientation parameters were then measured using 3D CT scans with digitally reconstructed radiographs (DRRs) by two independent observers. Bland-Altman plots were produced to determine the accuracy of glenoid orientation using standard intraoperative assessment compared to postoperative 3D CT scan results. Visual assessment of glenoid baseplate orientation showed “poor” to “fair” correlation to 3D CT DRR measurements for both novice and experienced surgeon groups for all measured parameters. There was a clinically relevant, large discrepancy between intra-operative visual assessments and 3D CT DRR measurements for all parameters. Errors in visual assessment of up to 19.2 degrees of inclination and 8mm supero-inferior COR offset occurred. Experienced surgeons had greater measurement error than novices for all measured parameters. Intra-operative measurement errors in glenoid placement may reach unacceptable clinical limits. Kinesthetic input during implantation likely improves orientation understanding and has implications for hands-on learning


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 2 - 2
7 Nov 2023
du Plessis JG Koch O le Roux T O'Connor M
Full Access

In reverse shoulder arthroplasty (RSA), a high complication rate is noted in the international literature (24.7%), and limited local literature is available. The complications in our developing health system, with high HIV, tuberculosis and metabolic syndrome prevalence may be different from that in developed health systems where the literature largely emanates from. The aim of this study is to describe the complications and complication rate following RSA in a South African cohort. An analytical, cross-sectional study was done where all patients’ who received RSA over an 11 year period at a tertiary hospital were evaluated. One-hundred-and-twenty-six primary RSA patients met the inclusion criteria and a detailed retrospective evaluation of their demographics, clinical variables and complication associated with their shoulder arthroplasty were assessed. All fracture, revision and tumour resection arthroplasties were excluded, and a minimum of 6 months follow up was required. A primary RSA complication rate of 19.0% (24/126) was noted, with the most complications occurring after 90 days at 54.2% (13/24). Instability was the predominant delayed complication at 61.5% (8/13) and sepsis being the most common in the early days at 45.5% (5/11). Haematoma formation, hardware failure and axillary nerve injury were also noted at 4.2% each (1/24). Keeping in mind the immense difference in socioeconomical status and patient demographics in a third world country the RSA complication rate in this study correlates with the known international consensus. This also proves that RSA is still a suitable option for rotator cuff arthropathy and glenohumeral osteoarthritis even in an economically constrained environment like South Africa


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 103 - 103
23 Feb 2023
Gupta V Van Niekerk M Hirner M
Full Access

Scapular notching is a common problem following reverse shoulder arthroplasty (RSA). This is due to impingement between the humeral polyethylene cup and scapular neck in adduction and external rotation. Various glenoid component strategies have been described to combat scapular notching and enhance impingement-free range of motion (ROM). There is limited data available detailing optimal glenosphere position in RSA with an onlay configuration. The purpose of this study was to determine which glenosphere configurations would maximise impingement free ROM using an onlay RSA prosthesis. A three-dimensional (3D) computed tomography (CT) scan of a shoulder with Walch A1, Favard E0 glenoid morphology was segmented using validated software. An onlay RSA prosthesis was implanted and a computer model simulated external rotation and adduction motion of the virtual RSA prosthesis. Four glenosphere parameters were tested; diameter (36mm, 41mm), lateralization (0mm, 3mm, 6mm), inferior tilt (neutral, 5 degrees, 10 degrees), and inferior eccentric positioning (0.5mm, 1.5mm. 2.5mm, 3.5mm, 4.5mm). Eighty-four combinations were simulated. For each simulation, the humeral neck-shaft angle was 147 degrees and retroversion was 30 degrees. The largest increase in impingement-free range of motion resulted from increasing inferior eccentric positioning, gaining 15.0 degrees for external rotation and 18.8 degrees for adduction. Glenosphere lateralization increased external rotation motion by 13. 6 degrees and adduction by 4.3 degrees. Implanting larger diameter glenospheres increased external rotation and adduction by 9.4 and 10.1 degrees respectively. Glenosphere tilt had a negligible effect on impingement-free ROM. Maximizing inferior glenosphere eccentricity, lateralizing the glenosphere, and implanting larger glenosphere diameters improves impingement-free range of motion, in particular external rotation, of an onlay RSA prosthesis. Surgeons’ awareness of these trends can help optimize glenoid component position to maximise impingement-free ROM for RSA. Further studies are required to validate these findings in the context of scapulothoracic motion and soft tissue constraints


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 627 - 634
1 Jun 2019
King JJ Dalton SS Gulotta LV Wright TW Schoch BS

Aims. Acromial fractures following reverse shoulder arthroplasty (RSA) have a wide range of incidences in reported case series. This study evaluates their incidence following RSA by systematically reviewing the current literature. Materials and Methods. A systematic review using the search terms “reverse shoulder”, “reverse total shoulder”, or “inverted shoulder” was performed using PubMed, Web of Science, and Cochrane databases between 1 January 2010 and 31 March 2018. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used. Studies were included if they reported on RSA outcomes and the incidence rate of acromial and/or scapular spine fractures. The rate of these fractures was evaluated for primary RSA, revision RSA, RSA indications, and RSA implant design. Results. The review included 90 articles out of 686 identified after exclusions. The incidence rate of acromial and/or scapular spine fractures was 2.8% (253/9048 RSAs). The fracture rate was similar for primary and revision RSA (2.8% vs 2.1%; p = 0.4). Acromial fractures were most common after RSA for inflammatory arthritis (10.9%) and massive rotator cuff tears (3.8%). The incidence was lowest in RSA for post-traumatic arthritis (2.1%) and acute proximal humerus fractures (0%). Lateralized glenosphere design had a significantly higher rate of acromial fractures compared with medial glenosphere designs. Conclusion. Based on current English literature, acromial and/or scapular spine fractures occur at a rate of 2.8% after RSA. The incidence is slightly more common after primary compared with revision arthroplasty. Also, higher rates of acromial fractures are reported in RSA performed for inflammatory arthritis and in the lateralized glenoid design. Cite this article: Bone Joint J 2019;101-B:627–634


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 50 - 50
1 Dec 2021
Mehta S Mahajan U Sathyamoorthy P
Full Access

Abstract. Background. The influence of diagnosis on outcomes after reverse shoulder arthroplasty (RSA) is not completely understood. The purpose of this study was to compare clinical outcomes of different pathologies. Methods. A total of 78 RSAs were performed for the following diagnoses: (1) rotator cuff tear arthropathy(RCA), (2) massive cuff tear(MCT) with osteoarthritis(OA), (3) MCT without OA, (4) arthritis, (5) acute proximal humerus fracture. Mean follow up 36 months (upto 5 years) Range of motion, Oxford Shoulder Score were obtained preoperatively and postoperatively. Results. Mean OSS was 30. The RCA, MCT-with-OA, MCT-without-OA, and arthritis groups all exhibited significant improvements in all outcome scores and in all planes of motion. After adjustment for age and compared with RCA, those with OA had significantly better abduction (P < .05), and those with fractures had significantly worse patient satisfaction (P < .05). Among male patients, those with MCTs without OA had significantly worse satisfaction (P < .05). Conclusion. RSA reliably provides improvement regardless of preoperative diagnosis. Although subtle differences exist between male and female patients, improvements in clinical outcome scores were apparent after RSA


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1520 - 1525
1 Dec 2019
Clark NJ Samuelsen BT Alentorn-Geli E Assenmacher AT Cofield RH Sperling JW Sánchez-Sotelo J

Aims. Reverse shoulder arthroplasty (RSA) reliably improves shoulder pain and function for a variety of indications. However, the safety and efficacy of RSA in elderly patients is largely unknown. The purpose of this study was to report the mortality, morbidity, complications, reoperations, and outcomes of primary RSA in patients aged > 80 years. Patients and Methods. Between 2004 and 2013, 242 consecutive primary RSAs were performed in patients aged > 80 years (mean 83.3 years (. sd. 3.1)). Of these, 53 were lost to follow-up before two years and ten had died within two years of surgery, leaving 179 for analysis of survivorship, pain, motion, and strength at a minimum of two years or until revision surgery. All 242 patients were considered for the analysis of 90-day, one-year, and overall mortality, medical complications (90-day and overall), surgical complications, and reoperations. The indications for surgery included rotator cuff arthropathy, osteoarthritis, fracture, the sequela of trauma, avascular necrosis, and rheumatoid arthritis. A retrospective review of the medical records was performed to collect all variables. Survivorship free of revision surgery was calculated at two and five years. Results. One patient (0.4%) died within the first 90 days. A total of 45 patients (19%) were known to have died at the time of the final follow-up, with a median time to death of 67.7 months (interquartile range 40.4 to 94.7) postoperatively. Medical complications occurred in six patients (3%) and surgical complications occurred in 21/179 patients (12%). Survivorship free from revision was 98.9% at two years and 98.3% at five years; survivorship free from loosening was 99.5% at final follow-up. The presence of peripheral vascular disease correlated with a higher complication rate. Conclusion. Primary RSA was safe and effective in patients aged > 80 years, with a relatively low rate of medical and surgical complications. Thus, age alone should not be a contraindication to primary RSA in patients aged > 80 years. However, a careful evaluation of comorbidities is required in this age group when considering primary RSA. Cite this article: Bone Joint J 2019;101-B:1520–1525


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 35 - 35
1 Dec 2022
Torkan L Bartlett K Nguyen K Bryant T Bicknell R Ploeg H
Full Access

Reverse shoulder arthroplasty (RSA) is commonly used to treat patients with rotator cuff tear arthropathy. Loosening of the glenoid component remains one of the principal modes of failure and is the main complication leading to revision. For optimal RSA implant osseointegration to occur, the micromotion between the baseplate and the bone must not exceed a threshold of 150 µm. Excess micromotion contributes to glenoid loosening. This study assessed the effects of various factors on glenoid baseplate micromotion for primary fixation of RSA. A half-fractional factorial experiment design (2k-1) was used to assess four factors: central element type (central peg or screw), central element cortical engagement according to length (13.5 or 23.5 mm), anterior-posterior (A-P) peripheral screw type (nonlocking or locking), and bone surrogate density (10 or 25 pounds per cubic foot [pcf]). This created eight unique conditions, each repeated five times for 40 total runs. Glenoid baseplates were implanted into high- or low-density Sawbones™ rigid polyurethane (PU) foam blocks and cyclically loaded at 60 degrees for 1000 cycles (500 N compressive force range) using a custom designed loading apparatus. Micromotion at the four peripheral screw positions was recorded using linear variable displacement transducers (LVDTs). Maximum micromotion was quantified as the displacement range at the implant-PU interface, averaged over the last 10 cycles of loading. Baseplates with short central elements that lacked cortical bone engagement generated 373% greater maximum micromotion at all peripheral screw positions compared to those with long central elements (p < 0.001). Central peg fixation generated 360% greater maximum micromotion than central screw fixation (p < 0.001). No significant effects were observed when varying A-P peripheral screw type or bone surrogate density. There were significant interactions between central element length and type (p < 0.001). An interaction existed between central element type and level of cortical engagement. A central screw and a long central element that engaged cortical bone reduced RSA baseplate micromotion. These findings serve to inform surgical decision-making regarding baseplate fixation elements to minimize the risk of glenoid loosening and thus, the need for revision surgery


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1493 - 1498
1 Nov 2018
Wagner ER Hevesi M Houdek MT Cofield RH Sperling JW Sanchez-Sotelo J

Aims. Patients with a failed reverse shoulder arthroplasty (RSA) have limited salvage options. The aim of this study was to determine the outcome of revision RSA when used as a salvage procedure for a failed primary RSA. Patients and Methods. We reviewed all revision RSAs performed for a failed primary RSA between 2006 and 2012, excluding patients with a follow-up of less than two years. A total of 27 revision RSAs were included in the study. The mean age of the patients at the time of revision was 70 years (58 to 82). Of the 27 patients, 14 (52% were female). The mean follow-up was 4.4 years (2 to 10). Results. Six patients (22%) developed complications requiring further revision surgery, at a mean of 1.7 years (0.1 to 5.3) postoperatively. The indication for further revision was dislocation in two, glenoid loosening in one, fracture of the humeral component in one, disassociation of the glenosphere in one, and infection in one. The five-year survival free of further revision was 85%. Five additional RSAs developed complications that did not need surgery, including dislocation in three and periprosthetic fracture in two. Overall, patients who did not require further revision had excellent pain relief, and significant improvements in elevation and external rotation of the shoulder (p < 0.01). The mean postoperative American Shoulder and Elbow Surgeons (ASES), and simple shoulder test (SST) scores were 66 and 7, respectively. Radiological results were available in 26 patients (96.3%) at a mean of 4.3 years (1.5 to 9.5). At the most recent follow-up, six patients (23%) had glenoid lucency, which were classified as grade III or higher in three (12%). Smokers had a significantly increased risk of glenoid lucency (p < 0.01). Conclusion. Revision RSA, when used to salvage a failed primary RSA, can be a successful procedure. At intermediate follow-up, survival rates are reasonable, but dislocation and glenoid lucency remain a concern, particularly in smokers. Cite this article: Bone Joint J 2018;100-B:1493–98


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 18 - 18
1 Nov 2021
Troiano E Facchini A Meglio MD Peri G Aiuto P Mondanelli N Giannotti S
Full Access

Introduction and Objective. In recent years, along with the extending longevity of patients and the increase in their functional demands, the number of annually performed RSA and the incidence of complications are also increasing. When a complication occurs, the patient often needs multiple surgeries to restore the function of the upper limb. Revision implants are directly responsible for the critical reduction of the bone stock, especially in the shoulder. The purpose of this paper is to report the use of allograft bone to restore the bone stock of the glenoid in the treatment of an aseptic glenoid component loosening after a reverse shoulder arthroplasty (RSA). Materials and Methods. An 86-years-old man came to our attention for aseptic glenoid component loosening after RSA. Plain radiographs showed a complete dislocation of the glenoid component with 2 broken screws in the neck of glenoid. CT scans confirmed the severe reduction of the glenoid bone stock and critical bone resorption and were used for the preoperative planning. To our opinion, given the critical bone defect, the only viable option was revision surgery with restoration of bone stock. We planned to use a bone graft harvested from distal bone bank femur as component augmentation. During the revision procedure the baseplate with a long central peg was implanted “on table” on the allograft and an appropriate osteotomy was made to customize the allograft on the glenoid defect according to the CT-based preoperative planning. The Bio-component was implanted with stable screws fixation on residual scapula. We decided not to replace the humeral component since it was stable and showed no signs of mobilization. Results. The new bio-implant was stable, and the patient gained a complete functional recovery of the shoulder. The scheduled radiological assessments up to 12 months showed no signs of bone resorption or mobilization of the glenoid component. Conclusions. The use of bone allograft in revision surgery after a RSA is a versatile and effective technique to treat severe glenoid bone loss and to improve the global stability of the implant. Furthermore, it represents a viable alternative to autologous graft since it requires shorter operative times and reduces graft site complications. There are very few data available regarding the use of allografts and, although the first studies are encouraging, further investigation is needed to determine the biological capabilities of the transplant and its validity in complex revisions after RSA


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1662 - 1667
1 Dec 2015
Weber-Spickschen TS Alfke D Agneskirchner JD

If a modular convertible total shoulder system is used as a primary implant for an anatomical total shoulder arthroplasty, failure of the prosthesis or the rotator cuff can be addressed by converting it to a reverse shoulder arthroplasty (RSA), with retention of the humeral stem and glenoid baseplate. This has the potential to reduce morbidity and improve the results. . In a retrospective study of 14 patients (15 shoulders) with a mean age of 70 years (47 to 83) we reviewed the clinical and radiological outcome of converting an anatomical shoulder arthroplasty (ASA) to a RSA using a convertible prosthetic system (SMR system, Lima, San Daniele, Italy). . The mean operating time was 64 minutes (45 to 75). All humeral stems and glenoid baseplates were found to be well-fixed and could be retained. There were no intra-operative or early post-operative complications and no post-operative infection. The mean follow-up was 43 months (21 to 83), by which time the mean visual analogue scale for pain had decreased from 8 pre-operatively to 1, the mean American Shoulder and Elbow Surgeons Score from 12 to 76, the mean Oxford shoulder score from 3 to 39, the mean Western Ontario Osteoarthritis of the Shoulder Score from 1618 to 418 and the mean Subjective shoulder value from 15 to 61. On radiological review, one patient had a lucency around the humeral stem, two had stress shielding. There were no fatigue fractures of the acromion but four cases of grade 1 scapular notching. . The use of a convertible prosthetic system to revise a failed ASA reduces morbidity and minimises the rate of complications. The mid-term clinical and radiological results of this technique are promising. Cite this article: Bone Joint J 2015;97-B:1662–7


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 2 - 2
1 Feb 2021
Pizzamiglio C Fattori A Rovere F Poon P Pressacco M
Full Access

Background. Stemless prostheses are recognized to be an effective solution for anatomic total shoulder arthroplasty (TSA) while providing bone preservation and shortest operating time. Reverse shoulder arthroplasty (RSA) with stemless has not showed the same effectiveness, as clinical and biomechanical performances strongly depend on the design. The main concern is related to stability and bone response due to the changed biomechanical conditions; few studies have analyzed these effects in anatomic designs through Finite Element Analysis (FEA), however there is currently no study analyzing the reverse configuration. Additionally, most of the studies do not consider the effect of changing the neck-shaft angle (NSA) resection of the humerus nor the proper assignment of spatial bone properties to the bone models used in the simulations. The aim of this FEA study is to analyze bone response and primary stability of the SMR Stemless prosthesis in reverse with two different NSA cuts and two different reverse angled liners, in bone models with properties assigned using a quantitative computed tomography (QCT) methodology. Methods. Sixteen fresh-frozen cadaveric humeri were modelled using the QCT-based finite element methodology. The humeri were CT-scanned with a hydroxyapatite phantom to allow spatial bone properties assignment [Fig. 1]. Two implanted SMR stemless reverse configurations were considered for each humerus: a 150°-NSA cut with a 0° liner and a 135°-NSA cut with a 7° sloped liner [Fig. 2]. A 105° abduction loading condition was simulated on both the implanted reverse models and the intact (anatomic) humerus; load components were derived from previous dynamic biomechanical simulations on RSA implants for the implanted stemless models and from the OrthoLoad database for the intact humeri. The postoperative bone volume expected to resorb or remodel [Fig. 3a] in the implanted humeri were compared with their intact models in sixteen metaphyseal regions of interest (four 5-mm thick layers parallel to the resection and four anatomical quadrants) by means of a three-way repeated measures ANOVA followed by post hoc tests with Bonferroni correction. In order to evaluate primary stability, micromotions at the bone-Trabecular Titanium interface [Fig. 3b] were compared between the two configurations using a Wilcoxon matched-pairs signed-rank test. The significance level α was set to 0.05. Results. With the exception of the most proximal layer (0.0 – 5.0 mm), the 150°-NSA configuration showed overall a statistically significant lower bone volume expected to resorb (p = 0.011). In terms of bone remodelling, the 150°-NSA configuration had again a better response, but fewer statistically significant differences were found. Regarding micromotions, there was a median decrease (Mdn = 3.2 μm) for the 135°-NSA configuration (Mdn = 40.3 μm) with respect to the 150°-NSA configuration (Mdn = 43.5 μm) but this difference was non-significant (p = 0.464). Conclusions. For the analyzed SMR Stemless configurations, these results suggest a reduction in the risk of bone resorption when a 0° liner is implanted with the humerus cut at 150°. The used QCT-based methodology will allow further investigation, as this study was limited to one single design and load case. For any figures or tables, please contact the authors directly


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 610 - 614
1 May 2019
Aibinder WR Bartels DW Sperling JW Sanchez-Sotelo J

Aims. Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in anatomical (TSA) and reverse shoulder arthroplasty (RSA). Patients and Methods. A total of 100 shoulder arthroplasties (35 TSA and 65 RSA) were evaluated at a mean of 3.8 years (3 to 8.3). The mean age at the time of surgery was 68 years (31 to 90). The mean body mass index was 32.7 kg/m. 2. (17.3 to 66.4). Results. Greater tuberosity stress shielding was noted in 14 shoulders (two TSA and 12 RSA) and was graded as mild in nine, moderate in two, and severe in three. Medial calcar resorption was noted in 23 shoulders (seven TSA and 16 RSA), and was graded as mild in 21 and moderate in two. No humeral components were revised for loosening or considered to be loose radiologically. Nine shoulders underwent reoperation for infection (n = 3), fracture of the humeral tray (n = 2), aseptic glenoid loosening (n = 1), and instability (n = 3). No periprosthetic fractures occurred. Conclusion. Implantation of this particular short cementless humeral component at the time of TSA or RSA was associated with a low rate of adverse radiological findings on the humeral side at mid-term follow-up. Our data do not raise any concerns regarding the use of a short stem in TSA or RSA. Cite this article: Bone Joint J 2019;101-B:610–614


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1182 - 1186
1 Sep 2018
Werner BS Chaoui J Walch G

Aims. Scapular notching is a frequently observed radiographic phenomenon in reverse shoulder arthroplasty (RSA), signifying impingement of components. The purposes of this study were to evaluate the effect of glenoid component size and glenosphere type on impingement-free range of movement (ROM) for extension and internal and external rotation in a virtual RSA model, and to determine the optimal configuration to reduce the incidence of friction-type scapular notching. Materials and Methods. Preoperative CT scans obtained in 21 patients (three male, 18 female) with primary osteoarthritis were analyzed using modelling software. Two concurrent factors were tested for impingement-free ROM and translation of the centre of rotation: glenosphere diameter (36 mm vs 39 mm) and type (centred, 2 mm inferior eccentric offset, 10° inferior tilt). Results. Glenosphere size was most predictive of increased extension and external rotation, whereas lateralization of the centre of rotation was the most predictive factor for internal rotation. A larger diameter of glenosphere combined with a 10° tilted configuration demonstrated superior values for extension and external rotation, whereas the eccentric component improved internal rotation by a mean 8.9° (standard deviation 2.7°) compared with a standard concentric glenosphere. Conclusion. Glenosphere configuration can be modified to increase range of movement in RSA. Friction-type scapular notching was most effectively reduced by use of a large-diameter glenosphere with 10° inferior tilt. Cite this article: Bone Joint J 2018;100-B:1182–6


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 10 - 10
1 Nov 2015
Burkhead W
Full Access

Management of bone loss on both sides of the glenohumeral joint has been made much easier by the introduction of the reverse shoulder arthroplasty (RSA). While traditional posterior bone grafting and newer augmented glenoid components are still being used for Walch type B2 glenoids, there is movement and the trend towards using the reverse prosthesis with Bone Ingrowth Offset (BIO-RSA) techniques. Bone loss on the humeral side can be managed by the prosthesis itself, fresh matched or frozen proximal humerus allografts, femoral shaft allografts, or tibial strut allografts. Several cases will be shown to illustrate each technique


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 15 - 15
1 Aug 2020
Ehrlich J Bryant T Rainbow M Bicknell R
Full Access

The purpose of this study is to quantify the distribution of bone density in the scapulae of patients undergoing reverse shoulder arthroplasty (RSA) to guide optimal screw placement. To achieve this aim, we compared bone density in regions around the glenoid that are targeted for screw placement, as well as bone density variations medial to lateral within the glenoid. Specimen included twelve scapula in 12 patients with a mean age of 74 years (standard deviation = 9.2 years). Each scapula underwent a computed tomography (CT) scan with a Lightspeed+ XCR 16-Slice CT scanner (General Electric, Milwaukee, USA). Three-dimensional (three-D) surface mesh models and masks of the scapulae containing three-D voxel locations along with the relative Hounsfield Units (HU) were created. Regions of interest (ROI) were selected based on their potential glenoid baseplate screw positioning in RSA surgery. These included the base of coracoid inferior and lateral to the suprascapular notch, an anterior and posterior portion of the scapular spine, and an anterosuperior and inferior portion of the lateral border. Five additional regions resembling a clock face, on the glenoid articular surface were then selected to analyze medial to lateral variations in bone density including twelve, three, six, and nine-o'clock positions as well as a central region. Analysis of Variance (ANOVA) tests were used to examine statistical differences in bone density between each region of interest (p < 0 .05). For the regional evaluation, the coracoid lateral to the suprascapular notch was significantly less dense than the inferior portion of the lateral border (mean difference = 85.6 HU, p=0.03), anterosuperior portion of the lateral border (mean difference = 82.7 HU, p=0.04), posterior spine (mean difference = 97.6 HU, p=0.007), and anterior spine (mean difference = 99.3 HU, p=0.006). For the medial to lateral evaluation, preliminary findings indicate a “U” pattern with the densest regions of bone in the glenoid most medially and most laterally with a region of less dense bone in-between. The results from this study utilizing clinical patient CT scans, showed similar results to those found in our previous cadaveric study where the coracoid region was significantly less dense than regions around the lateral scapular border and scapular spine. We also have found for medial to lateral bone density, a “U” distribution with the densest regions of bone most medially and most laterally in the glenoid, with a region of less dense bone between most medial and most lateral. Clinical applications for our results include a carefully planned trajectory when placing screws in the scapula, potentially avoiding the base of coracoid. Additionally, surgeons may choose variable screw lengths depending on the region of bone and its variation of density medial to lateral, and that screws that pass beyond the most lateral (subchondral) bone, will only achieve further purchase if they enter the denser bone more medially. We suspect that if surgeons strategically aim screw placement for the regions of higher bone density, they may be able to decrease micromotion in baseplate fixation and increase the longevity of RSA


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 76 - 76
1 Aug 2020
Habis A Bicknell R Mei X
Full Access

Reverse shoulder arthroplasty (RSA) has an increasing effective use in the treatment of patients with a variety of diagnoses, including rotator cuff deficiency, inflammatory arthritis, or failed shoulder prostheses. Glenoid bone loss is not uncommonly encountered in these cases due to the significant wear. Severe bone loss can compromise glenoid baseplate positioning and fixation, consequently increasing the risk for early component loosening, instability, and scapular notching. To manage severe glenoid bone deficiencies, bone grafts are commonly used. Although, many studies report outcome of bone grafting in revision RSA, the literature on humeral head autograft for glenoid bone loss in primary RSA is less robust. The purpose of this study is to evaluate the clinical and radiographic outcomes of primary RSA with humeral head autograft for glenoid bone loss at our institution. Institutional review board approval was obtained to retrospectively review the records of 22 consecutive primary RTSA surgeries in 21 patients with humeral head autograft for glenoid bone loss between January 2008 and December 2016. Five patients died during follow-up, three were unable to be contacted and one refused to participate, leaving a final study cohort of 12 patients with 13 shoulders that underwent RSA. All patients had a clinical evaluation including detailed ROM and clinical evaluation using the American Shoulder and Elbow Surgeons (ASES) Score, Constant Score, Western Ontario Osteoarthritis of the Shoulder Index (WOOS), and Short Form-12 (SF-12) questionnaires. Preoperative and postoperative plain radiographs and CT scans were assessed for component position, loosening, scapular notching, as well as graft incorporation, resorption, or collapse. There were 6 males and 6 females, with an average age of 74 ± 6.8 years. The average BMI was 31.7 ± 5.3, and the median ASA score was 3. Average follow-up was 3.4 ± 1.1 years. The average postoperative range of motion measurements for the operative arm are: flexion = 120 ± 37, abduction = 106 ± 23, external rotation = 14 ± 12, internal rotation at 90 degrees of abduction = 49 ± 7, external rotation at 90 degrees of abduction = 50 ± 28. Average functional scores are: ASES: 76.9 ± 19.2, WOOS: 456 ± 347, SF12 physical: 34.2 ± 8.2, SF12 mental: 54.1 ± 10.2, Constant Score: 64.6 ± 14. No evidence of hardware loosening or evidence of bone graft resorption were encountered. On CT, the average of pre operative B-angle was 79.3 ± 9.3 while the pre operative reverse shoulder angle was 101.4 ± 28. Glenoid retroversion average on CT was 13.3 ± 16.6. Post operative baseplate inclination average was 82 ± 7.4 while the baseplate version 7.8 ±10. The operative technique was able to achieve up to 30 degrees of inclination correction and up to 50 degrees of version correction. In conclusion, primary reverse shoulder arthroplasty with humeral head autograft for glenoid bone loss provides excellent ROM and functional outcomes at mid-term follow-up. This technique has a high rate of bone incorporation and small risk of bone resorption at mid term follow up


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 66 - 66
1 Dec 2017
Sabesan V Petersen-Fitts GR Lombardo DJ Liou W
Full Access

Manufacturers of reverse shoulder arthroplasty (RSA) implants have recently designed innovative implants to optimise performance in rotator cuff deficient shoulders. These advancements are not without tradeoff and can have negative biomechanical effects. The objective of this study was to develop an integrated FEA kinematic model to compare the muscle forces and joint reaction force (JRF) of 3 different RSA designs. A kinematic model of a normal shoulder joint was adapted from the Delft model and integrated with the OpenSim shoulder model. Static optimisations then allowed for calculation of the individual muscle forces, moment arms and JRF relative to net joint moments. Three dimensional computer models of humeral lateralised design (HLD), glenoid lateral design (GLD), and Grammont design (GD) RSA were integrated and parametric studies were performed. Overall there were decreases in deltoid and rotator cuff muscle forces for all 3 RSA designs. These decreases were greatest in the middle deltoid of the HLD model for abduction and flexion and in the rotator cuff muscles under both internal and external rotation. The joint reactive forces in abduction and flexion decreased similarly for all RSA designs compared to the normal shoulder model, with the greatest decrease seen in the HLD model. These findings demonstrate that the design characteristics implicit in these modified RSA prostheses result in kinematic differences most prominently seen in the deltoid muscle and overall joint reactive forces. Further research utilising this novel integrated model can help guide continued optimisation of RSA design and clinical outcomes


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 15 - 15
1 Apr 2019
Ramirez-Martinez I Smith S Joyce T
Full Access

INTRODUCTION. Shoulder joint prostheses have become the most commonly replaced after knee and hip artificial implants. Reverse shoulder arthroplasty (RSA) is the treatment option for patients with severe osteoarthritis, rotator cuff arthropathy or a massive rotator cuff tear with pseudoparalysis. Though successful, the long-term survival of such implants are limited by wear of the materials in contact [1, 2]. The aim of this study was to investigate RSA wear in vitro using a clinically relevant activities of daily living (ADLs). MATERIALS AND METHODS. Four new JRI Orthopaedics Reverse Shoulder 42 mm diameter VAIOS with cobalt-chromium (CoCr) glenospheres and ultra-high molecular weight polyethylene (UHMWPE) humeral components were tested. A five million cycles wear test was undertaken using the unique Newcastle Shoulder Wear Simulator with dilute bovine serum as a lubricant. “Mug to mouth” was performed as the ADL to the test prostheses in intervals of 100 cycles, following by 5 seconds of high load (450N) with no motion simulating an ADL such as “lifting an object”. This combined load cycle was then repeated. A fifth reverse shoulder prosthesis was subject to dynamic loading only in a soak control station. Wear was assessed gravimetrically and roughness (Sa) of the articulating surfaces was measured with a non-contacting profilometer. RESULTS AND DISCUSSION. The mean wear rate and standard deviation of the UHMWPE components was 11.4±3.7 mm. 3. /million cycles, while the CoCr components showed minimal wear over the test duration of 0.01± 0.02 mm. 3. /million cycles (Fig.1). Wear rates are comparable with Kohut et al. (14.1 mm. 3. /million cycles) [3] and Smith et al. (14.3±1.6 mm. 3. /million cycles) [4]. The CoCr glenospheres roughness was unchanged, from 32±8 nm Sa to 28±8 nm Sa over the 5 million cycles of the test (p=0.017), while the UHMWPE humeral components became smoother, from 692±123 nm Sa to 42±29 nm Sa (Fig.2), showing a statically significant change (p<0.001). CONCLUSION. The present study is the first wear test of artificial shoulder joints using a Motion-Load-Motion configuration as a clinically relevant physiological pattern of motion and load. Results are comparable with those found in the literature for in vitro testing of reverse shoulder replacements. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 41 - 41
1 Feb 2020
Studders C Saliken D Shirzadi H Athwal G Giles J
Full Access

INTRODUCTION. Reverse shoulder arthroplasty (RSA) provides an effective alternative to anatomic shoulder replacements for individuals with cuff tear arthropathy, but certain osteoarthritic glenoid deformities make it challenging to achieve sufficient long term fixation. To compensate for bone loss, increase available bone stock, and lateralize the glenohumeral joint center of rotation, bony increased offset RSA (BIO-RSA) uses a cancellous autograft for baseplate augmentation that is harvested prior to humeral head resection. The motivations for this computational study are twofold: finite element (FE) studies of BIO-RSA are absent from the literature, and guidance in the literature on screw orientations that achieve optimal fixation varies. This study computationally evaluates how screw configuration affects BIO-RSA graft micromotion relative to the implant baseplate and glenoid. METHODS. A senior shoulder specialist (GSA) selected a scapula with a Walch Type B2 deformity from patient CT scans. DICOM images were converted to a 3D model, which underwent simulated BIO-RSA with three screw configurations: 2 divergent superior & inferior locking screws with 2 convergent anterior & posterior compression screws (SILS); 2 convergent anterior & posterior locking screws and 2 superior & inferior compression screws parallel to the baseplate central peg (APLS); and 2 divergent superior & inferior locking screws and 2 divergent anterior & posterior compression screws (AD). The scapula was assigned heterogeneous bone material properties based on the DICOM images’ Hounsfield unit (HU) values, and other components were assigned homogenous properties. Models were then imported into an FE program for analysis. Anterior-posterior and superior-inferior point loads and a lateral-medial distributed load simulated physiologic loading. Micromotion data between the RSA baseplate and bone graft as well as between the bone graft and glenoid were sub-divided into four quadrants. RESULTS. In all but 1 quadrant, APLS performed the worst with the graft having an average micromotion of 347.1µm & 355.9 µm relative to the glenoid and baseplate, respectively. The SILS configuration ranked second, having 211.2 µm & 274.4 µm relative to the glenoid and baseplate. AD performed best, allowing 247.4 µm & 225.4 µm of graft micromotion relative to the glenoid and baseplate. DISCUSSION. Both APLS and SILS techniques are described in the literature for BIO-RSA fixation; however, the data indicate that AD is superior in its ability to reduce graft micromotion, and thus some revision to common practices may be necessary. While these micromotion data are larger than data in the extant RSA literature, there are several factors that account for this. First, to properly model the difference between locking and compression screws, we simulated friction between the compression screw heads and baseplate rather than a tied constraint as done in other studies, resulting in larger micromotion. Second, the trabecular bone graft is at greater risk of deforming than metallic spacers used when studying micromotion with glenosphere lateralization, increasing graft deflection magnitude. Future work will investigate the effects of various BIO-RSA variables. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 54 - 54
1 Mar 2017
Levy J Kurowicki J Triplet J
Full Access

Background. Locked anterior shoulders (LAS) with static instability and anterior glenoid bone loss are challenging in the elderly population. Reverse shoulder arthroplasty (RSA) has been employed in treating these patients. No study has compared RSA for LAS to classically indicated RSA. Methods. A case-control study of patients treated with RSA for LAS with glenoid bone loss and static instability was performed using matched controls treated with primary RSA for classic indications. Twenty-four cases and 48 controls were evaluated. Average follow-up was 25.5 months and median age was 76. Motion, outcome assessments, and postoperative radiographs were compared. Results. Preoperatively, LAS had significantly less rotation and lower baseline outcome scores. Glenoid bone grafting was more common (p=0.05) in control group (26%) than LAS group (6.3%). Larger glenospheres were utilized more often (p=0.001) in LAS group (75%) than control group (29%). Both groups demonstrated significant improvements in pain, function, and outcome scores. Postoperatively, control group had significantly better elevation and functional outcome scores. With the exception of flexion and SST, effectiveness of treatment was similar between groups. Postoperative acromion stress fractures were seen in 21% of LAS and 9% of control (p=0.023) with a predominance of type 3 fractures in LAS. Two LAS patients remained dislocated. Conclusion. Treatment with RSA for LAS may anticipate improvements in pain and function using larger glenospheres often without the need for glenoid bone grafting. Worse postoperative motion, function, and a higher incidence of acromion stress fracture may be expected


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 92 - 92
1 Feb 2017
Levy J Rosas S Law T Kurowicki J Kalandiak S
Full Access

Background. Operative treatment of complex proximal humerus fractures remains controversial. The transition to value-based health care demands a better understanding of the costs associated with surgery. The purpose of this study was to examine the 90-day costs of three common surgical treatments for proximal humerus fractures and non-operative treatment and compare the costs associated with the initial-day and subsequent 89-days of care. Methods. A query of the Humana insurance claims database was performed through the PearlDiver Supercomputer (Warsaw, IN) from 2010 to 2014 using the diagnosis codes for proximal humerus fractures together with current procedural terminology codes (CPT) for hemiarthroplasties (HA), open reduction internal fixation (ORIF), reverse shoulder arthroplasty (RSA) and nonoperative treatment (NO). Reimbursement from the insurance claims database was used as a marker for costs. The same day, subsequent 89-day, and ninety day costs were analyzed trough the use of descriptive and comparative statistical analysis. Results. RSA was the most costly procedure for the same-day and 90-day costs (p<0.001) (Figure 1). Mean initial-day reimbursement costs were significantly different amongst treatment groups, with the highest costs seen with RSA ($16,151), followed by HA ($9,348), ORIF ($6,745) and lastly, NO ($1,932). Subsequent 89-day reimbursement costs were not significantly different for RSA, HA and ORIF (p=0.112) (Figure 1 and 2); however, NO treatment incurred significantly lower costs (p=0.008) (Figure 3). Conclusion. The 90-day costs for the surgical treatment of proximal humerus fractures are driven by the initial-day costs. RSA was associated with the highest cost, followed by HA and ORIF. NO management incurred the lowest costs


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 90 - 90
1 Feb 2017
Levy J Kurowicki J Law T Rosas S
Full Access

Background. Both anatomic (TSA) and reverse shoulder arthroplasty (RSA) are routinely performed for patients whom desire to continue to work or participate in sports. The purpose of this study is to analyze and compare the ability of patients to work and participate in sports based on responses to clinical outcome surveys. Methods. A retrospective review of 335 patients treated with TSA (179 patients) and RSA (156 patients) who completed questions 9 and 10 on the activity patient self-evaluation portion of the American Shoulder and Elbow Surgeons (ASES) Assessment Form was performed at average 30 months follow-up. Comparisons were made between TSA and RSA for the specific ASES score (rated 0–3) reported for usual work and sport, as well as ASES total score. Sports were subdivided based on those that predominantly use shoulder function. Results. Patients treated with TSA had a 32% greater ability to participate in sports (average specific ASES score 2.5 vs 1.9, p=0.001), with significantly higher scores for aquatic and sedentary sports (Figure 1). TSA patients demonstrated greater ability to participate in sports requiring shoulder function without difficulty, as 62% reported maximal scores (p=0.001) (Figure 2). TSA patients also demonstrated a 21% greater ability to perform work (average specific ASES score 2.6 vs. 2.1, p=0.001), with significantly higher scores for housework and gardening (Figure 3). Conclusion. Both TSA and RSA allow for participation in work and sport, with TSA patients reporting better overall ability to participate. For sports involving shoulder function, TSA patients more commonly report maximal ability to participate than RSA patients


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 78 - 78
1 Apr 2019
Fattori A Kontaxis A Chen X Vidoni G Castagna A Pressacco M
Full Access

Introduction. Reverse Shoulder Arthroplasty (RSA) is recognized to be an effective solution for rotator cuff deficient arthritic shoulders, but there are still concerns about impingement and range of motion (ROM). Several RSA biomechanical studies have shown that humeral lateralization can increase ROM in planar motions (e.g. abduction). However, there is still a debate whether humeral lateralization should be achieved with a larger sphere diameter or by lateralizing the center of rotation (COR). The latter has shown to decrease the deltoid moment arm and increase shear forces, where the former may pose challenges in implanting the device in small patients. The aim of this study was to evaluate how humeral lateralization achieved by varying COR lateral offset and glenosphere diameter in a reverse implant can affect impingement during activities of daily living (ADLs). Methods. Nine shoulder CT scans were obtained from healthy subjects. A reverse SMR implant (LimaCorporate, IT) was virtually implanted on the glenoid and humerus (neck-shaft angle 150°) as per surgical technique using Mimics software (Materialise NV). Implant positioning was assessed and approved by a senior surgeon. The 3D models were imported into a validated shoulder computational model (Newcastle Shoulder Model) to study the effects of humeral lateralization. The main design parameters considered were glenosphere diameter (concentric Ø36mm, Ø40mm, Ø44mm) and COR offset (standard, +2mm, +5mm), for a total of 9 combinations for each subject; −10°, 0° and 10° humeral components versions were analyzed. The model calculated the percentage of impingement (intra-articular, contact of cup with scapula neck and glenoid border; extra-articular, contact of humerus with acromion and coracoid) during 5 ADLs (hand to opposite shoulder, hand to back of head, hand to mouth, drink from mug and place object to head height). Results. On average, the Ø40mm and Ø44mm glenosphere resulted in significantly less impingement across ADLs compared to Ø36mm (−31% and −35% respectively). Humeral version and lateralization had no significant effect on impingement for the Ø44mm glenosphere. However, lateralization of +5 mm substantially reduced impingement on the Ø36mm glenosphere but the effect was significant only for the neutral 0° version (−42%) and 10° (−50%) anteversion. Discussion and Conclusions. The results of this study suggest that, for the SMR Reverse prosthesis, humeral lateralization through the increase of glenosphere diameter was the most efficient way to reduce impingement during ADLs compared to the lateralization of the COR. Humeral version can also affect the impact of lateralization on impingement during ADLs; in this study, the impingement for the Ø36mm glenosphere with 10° retroversion was not decreased through lateralization; this may be related to the combined effect of version and scapular morphology. Considering that using larger glenosphere diameter without offsetting the COR theoretically does not reduce overall deltoid lever arm nor increase the shear forces on the glenoid component, this should be the preferable option whenever possible. However, concerns over soft tissue over-tensioning may necessitate the use of a smaller diameter glenosphere in some patients


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 14 - 14
1 Nov 2015
Romeo A
Full Access

Total shoulder arthroplasty (TSA) and reverse shoulder arthroplasty (RSA) are excellent surgical options for individuals with shoulder arthritis, providing good to excellent results in the vast majority of patients. Complications are rare, but can be devastating for both the patient and surgeon. An uncommon, but extremely problematic complication following shoulder arthroplasty is shoulder stiffness. While substantial literature discussing post-arthroplasty stiffness is available for other joints such as the hip, knee, and elbow, there is a paucity of research available discussing this complication in the shoulder. As noted in multiple reviews, diminished range of motion following TSA or RSA may be due to a number of factors, including pre-operative diagnosis of proximal humerus fracture, inadequate post-operative rehabilitation, implant-related factors such as malpositioning and/or inappropriate-sized implants, and heterotopic ossification. Often, pathology leading to post-arthroplasty stiffness involves scarring of the long head of the biceps tendon, rotator cuff impingement, as well as cuff tendonitis. Periprosthetic joint infection (PJI) is also important to recognise, and may be difficult to diagnose, especially in cases of Propionibacterium acnes infections. Importantly, PJI may present with stiffness as well as instability, and thus a high index of suspicion with a low threshold to aspirate is necessary in these challenging patients. Treatment of patients with stiffness following arthroplasty is challenging, and may involve arthroscopic intervention with or without manipulation, as well as manipulation under anesthesia alone. This paper will discuss the etiology, work-up, and treatment of patients with shoulder stiffness following TSA and RSA


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 127 - 127
1 Mar 2017
Levy J Rosas S Law T Kalandiak S
Full Access

Purpose. The purpose of this study was to evaluate the effect of common medical comorbidities on the reimbursements of different shoulder arthroplasty procedures. Methods. We conducted a retrospective query of a private payer insurance claims database of prospectively collected data (PealDiver). Our search included the Current Procedural Terminology Codes (CPT) and International Classification of Disease (ICD) ninth edition codes for Total Shoulder Arthroplasty (TSA), Hemiarthroplasty (HA) and Reverse Shoulder Arthroplasty (RSA). Medical comorbidities were also searched for through ICD codes. The comorbidities selected for analysis were obesity, morbid obesity, hypertension, smoking, diabetes mellitus, hyperlipidemia, atrial fibrillation, chronic obstructive pulmonary disease (COPD), cirrhosis, depression and chronic kidney disease (CKD) (excluding end stage renal disease). The study period comprised claims from 2010 to 2014. The reimbursement charges of the day of surgery, 90-day global period and 90-day period excluding the initial surgical day of each comorbidity were analyzed and compared. Statistical analysis was conducted trough analysis of variance (ANOVA) when the data was normally distributed or through Kruskal-Wallis comparison when it was not. An alpha value of less than 0.05 was deemed as significant. Results. Comorbidities did not have a significant effect on same day reimbursements (Figure 1), but instead caused a significant effect on the 90-day global period reimbursements in the TSA and RSA cohorts (figure 2). For TSA and RSA the highest reimbursed patients at the 90-day period following surgery were the ones that had a diagnosis of Hepatitis C followed by atrial fibrillation and later COPD. For HA the same was true in the following order: Hepatitis C, Cirrhosis and atrial fibrillation (Figure 3). Conclusion. Shoulder arthroplasty reimbursements are significantly affected by comorbidities at time intervals following the initial surgical day. For figures/tables, please contact authors directly.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 47 - 47
1 Jan 2016
De Biase C Delcogliano M Borroni M Marotta D Ziveri G Pittalis G Castagna A
Full Access

Introduction. Reverse shoulder prosthesis has been developed to treat the clinical and pathological condition noted as cuff tear arthropathy (CTA). The current models of reverse shoulder arthroplasty (RSA) expose the procedure to the risk of scapular notching, possibly leading to loosening of the glenoid. Aim. The purpose of this study was to report updated results at a minimum follow-up of four years of 25 patients underwent reverse shoulder arthroplasty between 2006 and 2010 with an eccentric 36-mm glenoid component (SMR Lima). Methods. Clinical and radiographic evaluation was performed preoperatively and at every year of follow-up. All patients were evaluated with MRI or CT scan preoperatively and with X-ray examinations postoperatively to evaluate the presence of inferior scapular notching. To value the clinical outcome the Constant score and VAS score have been evaluated preoperatively and every year of follow up. Results. Since the last report the mean Constant remain stable (63.11±8.92) and the mean VAS score decreased to 1.75±2.38 (p<0.005). Radiographs showed one case of grade 1 inferior scapular notching at 7-year follow-up. Notching didn't have any influence on clinical outcome. In two patients radiolucent lines were visible around the central peg or screws. No patient had glenoid baseplate loosening or baseplate failure. Conclusion. Satisfactory results have been achieved in the treatment of cuff-deficient shoulder conditions with reverse shoulder arthroplasty using an eccentric glenosphere at medium follow up. The patients have maintained their improved function with durable clinical and radiographic results at a minimum of four years


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 85 - 85
1 Dec 2015
Gamba C Diez J Prieto D Fabrego A Verdie L Perez F Canovas C
Full Access

Successfully treatment of acute shoulder arthroplasty infections strongly depends on the timing of treatment. The objective of this study is to determine the normalization curve of C-reactive protein (CRP) after shoulder arthroplasty. Prospective study including 63 patients undergoing shoulder arthroplasty (46 reverse shoulder arthroplasty (RSA) and 17 total shoulder (TSA)). Mean age 74.1 years old. 25 cuff deficient shoulders, 14 acute fractures, 19 primary gleno-humeral arthritis and 5 fracture sequel were included. Blood samples to determine CRP were obtained before surgery the day of surgery, 24 and 48 hours after surgery and then 6, 8 and 14 days after surgery (data of blood samples was determined based on a previous limited study). Co-morbidities that could interfere CRP were also recorded. Normal value of CRP before surgery (mean 1.28) slightly increases 24 hours after surgery (mean 3.92), reach maximum value at 48 hours after surgery (mean 6.91) and then slowly decreases to normalize at 14 days (6th day mean 3.80, 8th day 2.33 and 14th day 1.08). Normalization curve is not affected by age, diagnosis or type of arthroplasty. CRP after shoulder arthroplasty reaches maximum value at 48h and then slowly decreases to become normal at 14 days. Any deviation from this normalization curve may help in diagnosis and early treatment of acute shoulder arthroplasty infections


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_12 | Pages 7 - 7
1 Jul 2014
Crosby L
Full Access

Reverse shoulder arthroplasty (RSA) was released into the United States market in 2004 for the indication of Rotator Cuff Tear Arthropathy. Since that time the indications have widened and now include massive rotator cuff tears that are not deemed to be surgically repairable. This diagnosis includes patients that are considered young in terms of shoulder replacement surgery. These patients do not have the radiographic changes of arthropathy, but most have undergone multiple surgical procedures in the past to attempt to repair the rotator cuff deficiency. These younger patients have a different post-op expectation than the patient with advanced arthropathy over the age of 70. The complication rate seen in this younger patient population is higher than seen in the older population undergoing RSA. The post-operative survey for satisfaction is also considerably lower in the younger population group. RSA for massive rotator cuff tears in a younger population under the age of 65 years gives a lower patient satisfaction result and a higher complication rate than age-matched patients older than 65 years. Although this is still the best procedure available for this difficult diagnosis, patients younger than 65 years should be consulted as to what their expectations are post-operatively. Pain relief is still the main reason to undergo an RSA


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 94 - 94
1 May 2016
Sabesan V Lombardo D Khan J Wiater J
Full Access

Purpose. With growing attention being paid to quality and cost effectiveness in healthcare, outcome evaluations are becoming increasingly important. This determination can be especially difficult in reverse shoulder arthroplasty (RSA) given the complex pathology and extensive disabilities in this patient population. Several different scoring systems have been developed and validated for use in various shoulder pathologies. The purpose of this study was to assess the use three outcome scores in a population of patients undergoing RSA. We aim to demonstrate the validity of three outcome scores in patients undergoing RSA, and to determine if one score or a combination of scores is superior to others. Methods. Using a database of patients treated with RSA, we assessed preoperative and postoperative Constant Scores, American Shoulder and Elbow Surgeons (ASES) scores, and subjective shoulder values (SSV) in 148 shoulders. The outcomes at each scoring period were described and the scores were compared to one another as well as to active range of motion using linear regression modeling. Results. There were no significant differences in the mean improvement of any of the scores. All of the outcome scales improvements were correlated with each other and improvement in forward elevation but not with external rotation. Using multivariate regression analysis all 3 outcome measures were able to predict 38.9% of the variation in improvement in functional outcomes (forward elevation). This was only slightly greater than that provided by improvements in the outcome variable CS alone (36.7%). Conclusion. The three shoulder outcome scores evaluated, regardless of whether they were patient reported or physician based, appear to appropriately reflect improvements after RSA with equal validity. The objective physician assessed Constant score had the strongest correlation with function of the arm, and use of a combination of all 3 outcome scores does not increase the ability to predict range of motion compared to using the Constant Score alone


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 319 - 319
1 Dec 2013
Galasso O Gasparini G Castricini R Mastroianni V
Full Access

BACKGROUND:. Few studies have evaluated at a medium-term follow-up the use of semiconstrained reverse shoulder arthroplasty (RSA) for primary glenohumeral osteoarthritis, massive rotator cuff tear, or cuff tear arthropathy excluding any other shoulder disease. Moreover, data on patients' quality of life after this surgery are lacking. METHODS:. In this prospective cohort study, 80 patients were evaluated after an RSA for either primary osteoarthritis, massive rotator cuff tear, or cuff tear arthropathy with the Constant-Murley score (CMS), ROM, and Short Form Health Survey (SF-36). A radiologic assessment was performed pre- and postoperatively. RESULTS:. At a mean 5-year follow-up, the cumulative survival rate was 97.3% and significant improvements in the CMS and ROM were observed when compared with the baseline values. The CMS was 93.2% of the sex- and age-matched normal values. The postoperative SF-36 scores showed no significant differences compared with normative data. Younger patients and subjects with worse preoperative conditions achieved the greatest benefit after RSA. A 70% scapular notching rate was noted and the length of follow-up was found to be associated with the severity of scapular notching. CONCLUSIONS:. This study introduces new predictors for surgical outcomes, and it shows that patients who had undergone RSA a mean of 5 years earlier exhibit similar functionality and health-related quality of life with respect to healthy controls


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 65 - 74
1 Jan 2016
Phadnis J Huang T Watts A Krishnan J Bain GI

Aims. To date, there is insufficient evidence available to compare the outcome of cemented and uncemented fixation of the humeral stem in reverse shoulder arthroplasty (RSA). . Methods. A systemic review comprising 41 clinical studies was performed to compare the functional outcome and rate of complications of cemented and uncemented stems in RSA. These included 1455 cemented and 329 uncemented shoulders. The clinical characteristics of the two groups were similar. Variables were compared using pooled frequency-weighted means and relative risk ratios (RR). Results. Uncemented stems had a significantly higher incidence of early humeral stem migration (p < 0.001, RR 18.1, 95% confidence interval (CI) 5.0 to 65.2) and non-progressive radiolucent lines (p < 0.001, RR 2.4, 95% CI 1.7 to 3.4), but a significantly lower incidence of post-operative fractures of the acromion compared with cemented stems (p = 0.004, RR 14.3, 95% CI 0.9 to 232.8). There was no difference in the risk of stem loosening or revision between the groups. The cemented stems had a greater relative risk of infection (RR 3.3, 95% CI 0.8 to 13.7), nerve injury (RR 5.7, 95% CI 0.7 to 41.5) and thromboembolism (RR 3.9, 95% CI 0.2 to 66.6). The functional outcome and range of movement were equivalent in the two groups. . Discussion. RSA performed with an uncemented stem gives them equivalent functional outcome and a better complication profile than with a cemented stem. The natural history and clinical relevance of early stem migration and radiolucent lines found with uncemented stems requires further long-term study. Take home message: This study demonstrates that uncemented stems have at least equivalent clinical and radiographic outcomes compared with cemented stems when used for reverse total shoulder arthroplasty. . Cite this article: Bone Joint J 2016;98-B:65–74


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 516 - 516
1 Dec 2013
Sabesan V Callanan M Sharma V Ghareeb G Moravek J Wiater JM
Full Access

Background. There has been increased focus on understanding the risk factors associated with scapular notching in reverse shoulder arthroplasty (RSA). The purpose of this study is to evaluate the effect of scapular morphology and surgical technique on the occurrence of scapular notching using the notching index as a comprehensive predictive tool. Methods. Ninety-one patients treated with a primary RSA were followed for a minimum of 24 months. Using a previously published notching index formula ((PSNA × 0.13) + (PGRD)), a notching index value for all patients was calculated. Radiographic assessment of patients were grouped by Nerot grade of scapular notching, group mean differences for prosthetic scapular neck angle (PSNA), peg glenoid rim distance (PGRD), preoperative scapular neck angle (SNA), notching index and clinical outcomes were compared. Results. Seventy-five (82%) of the ninety one shoulders in the study developed scapular notching. There was no significant difference in average notching index for group 1, 31.8 ± 4.4, and group 2, 33.1 ± 7.2. No significant difference was demonstrated between the groups for SNA (102.7° vs. 105.4°, p = 0.3), PSNA (125.8° vs. 124.5°, p = 0.82), PGRD (15.4 mm vs. 16.8 mm, p = 0.47) or in clinical outcomes between groups. Discussion. Our results demonstrated an overall low notch index that lacked specificity in predicting notching for this cohort. These results suggest that perhaps PSNA and prosthetic design are more significant contributors to notching with certain scapular morphology


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 283 - 283
1 Dec 2013
De Caro F De Biase C Ziveri G Delcogliano M Borroni M Castagna A
Full Access

Introduction:. Reverse shoulder arthroplasty (RSA) is a reasonable treatment modality in patients with Cuff Tear Arthropaty and massive irreparable cuff tears. RSA has been shown to increase patient function and decrease pain. The aim of this study is to evaluate the clinical and radiographic results of a 44 polyethylene glenosphere. Methods:. Since 2008 we treated 88 patients with cuff tear arthropaty and irreparable massive cuff tear, using an RSA. We selected 80 patients with minimum FU of 24 months in which we used an implant with polyethylene glenosphere and metal humeral insert. Size of the glenosphere used was 44. All patients were assessed with the Constant score and with VAS. The shoulder ROM was measured preoperatively and postoperatively. Results:. Average age of the patients was 71 years old. Average duration of FU was 34 months. All measures improved significantly (p < 0.0001). The mean Constant improved from 15.6 to 60.2. VAS improved from 6 to 2,5. Forward flexion increased from 40 ° to 126,4 °, abduction from 41 ° to 103 °, external rotation from 15.1 to 17.3 and internal rotation increased by two level. We report 22 cases of scapular notching without clinical influence and without implant mobilization. Conclusion:. This is the first report of the use of a polyethylene glenosphere. Data from this study suggest that RSA with a polyethylene glenosphere may be a viable treatment for patients with glenohumeral arthritis and a massive rotator cuff tear. Future studies will be necessary to determine the longevity of the implant and whether it will provide continued improvement in function


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 82 - 82
1 Aug 2013
Breckon C de Beer T Barrow A
Full Access

Reverse Shoulder Arthroplasty (RSA) has been widely accepted for the treatment of rotator cuff arthropathy. There are a number of other shoulder pathologies where the reverse shoulder prosthesis can salvage previously untreatable shoulder conditions and restore function to the shoulder. This is a series of cases where RSA has been used to treat shoulder fractures. Material. Our indications for the reverse prosthesis in fracture management were:. Revision of failed fracture fixation with a deficient rotator cuff – 2 patients;. Acute 3 and 4 part fractures in the elderly, osteoporotic – 1 patient;. Acute 4 part fracture dislocation in elderly, osteoporotic – 1 patient;. Revision of non-union and malunions – 5 patients;. Revision of hemiarthroplasties which were initially done for fracture management – 5 patients. Results. There were a total of 14 cases treated for fractures out of 123 reverse shoulder arthroplasties performed. The average age for the fracture cases was 68 years (range 47–87) and for non-fracture RSA cases 73 years (range 51–88). The average follow-up Constant Score was 53 for fracture cases and 67 for non-fracture RSA cases. Complications included 1 dislocation and 1 deep infection. The problem with treatment of complex cases is there is an increased risk of complications. Problems encountered in the use of reverse shoulder arthroplasty in complex diagnoses include: instability, notching of scapula, scapula fractures, sepsis, lack of bone stock, poor quality soft-tissue and deficient deltoid muscle due to numerous previous surgical procedures, distortion of anatomy due to trauma, subscapularis deficiency and problems encountered from metal implants in situ. Conclusion. RSA is a good salvage procedure for cuff deficient shoulder fracture cases


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 13 - 13
1 May 2016
Lombardo D Yang Y Liou W Frank C Sabesan V
Full Access

Introduction. Reverse Shoulder Arthroplasty (RSA) improves the mechanics of rotator cuff deficient shoulders. To optimize functional outcomes and minimize failures of the RSA manufacturers have recently made innovative design modifications with lateralized components. However, these innovations have their own set of biomechanical trade-offs, such as increased shear forces along the glenoid bone interface. The objective of this study was to develop an efficient musculoskeletal model to evaluate and compare both the muscle forces and joint reactive force of a normal shoulder to those implanted with varied RSA implant designs. We believe these findings will provide valuable insight into possible advantages or shortcomings of this new RSA design. Methods. A kinematic model of a normal shoulder joint was adapted from publically available musculoskeletal modeling software. Static optimizations then allowed for calculation of the individual muscle forces, moment arms and joint reactive forces relative to net joint moments. An accurate 3D computer models of humeral lateralized design (HLD) (Equinoxe, Exactech, Gainesville FL, USA), glenoid lateral design (GLD) (Encore, DJO Global, Vista CA, USA), and Grammont design (GD) (Aequalis, Tornier, Amsterdam, NV) reverse shoulder prostheses was also developed and parametric studies were performed based on the numerical simulation platform. Results. As expected, there were decreases in muscle forces in all RSA models (Table 1). These decreases were greatest in the middle deltoid of the HLD model for abduction and flexion (Figure 1) and in the rotator cuff muscles under both internal and external rotation (Figure 2). In all RSA models the muscle forces of the rotator cuff were diminished to near zero in all range of motions. The joint reactive forces in abduction and flexion decreased similarly for all RSA models compared to the normal shoulder model, with the greatest decrease again seen in the HLD model (Table 1). Conclusion. These findings demonstrate that the design characteristics implicit in these modified RSA prostheses result in kinematic differences most prominently seen in the deltoid muscle and overall joint reactive forces. These differences could have a profound effect on the ultimate clinical success and long term outcomes for RSA. These results can help guide continued optimization of RSA design and clinical outcomes. The developed innovative shoulder modeling simulation could serve as a prototype for testing of future implant design concepts


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 170 - 170
1 Sep 2012
Alami GB Rumian A Chuinard C Roussanne Y Boileau P
Full Access

Purpose. While reverse shoulder arthroplasty (RSA) corrects vertical muscle imbalance, it cannot restore the horizontal imbalance seen in cuff-deficient shoulders with combined loss of active elevation and external rotation (CLEER). We report the medium-term results of the modified latissimus dorsi/teres major tendon transfer (L'Episcopo procedure) associated with RSA, performed via a single deltopectoral approach. Method. Sixteen CLEER patients underwent the procedure and were followed up at a mean of 49 months (range, 36–70). All patients had lost spatial control of their arm, were unable to maintain neutral rotation, and had abnormal infraspinatus and teres minor muscles on imaging. Outcome measures included Constant score (CS), Subjective Shoulder Value (SSV), and ADLER score (activities of daily living requiring external rotation). Results. Fifteen patients were satisfied or very satisfied. There were significant improvements (p<0.05) in active elevation (72 degrees to 139 degrees), active external rotation (−24 degrees to 4 degrees), CS (27 to 64), ADLER score (5.0 to 23.8) and SSV (23% to 77%). Active internal rotation decreased from 6 to 3 points. Scapular notching was observed in 3 patients and spurs in 3 patients. One deep infection required two-stage revision of the prosthesis and the patient was disappointed with the result. One patient required reoperation (arthrolysis and acromioclavicular joint excision). Conclusion. Reverse shoulder arthroplasty combined with the modified L'Episcopo procedure improves shoulder function in patients with CLEER. Patients regain spatial control of their arm. The observed internal rotation loss has led us to modify the surgical technique by fixing the transferred tendons more posteriorly on the humerus


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 11 - 11
1 Dec 2016
Daalder M Venne G Rainbow M Bryant T Bicknell R
Full Access

While reverse shoulder arthroplasty (RSA) is a reliable treatment option for patients with rotator cuff deficiency, loss of glenoid baseplate fixation often occurs due to screw loosening. We questioned whether an analysis of the trabecular bone density distribution in the scapula would indicate more optimal sites for screw placement. As such, the purpose of this study was to determine the anatomic distribution of trabecular bone density in regions of the scapula available for screw placement in RSA. Seven cadaveric shoulders were computed tomography (CT) scanned, and then voxels of the scapulae were isolated from the CT volume (Mimics 15.0 Materialise, Leuven, Belgium). Analyses were conducted in a common, 3D coordinate system. Volumetric regions of interest (ROI) within the scapula were identified based on potential baseplate screw sites. ROIs included areas at the base of the coracoid process lateral and inferior to the suprascapular notch, in the posterior and anterior lateral spine and in the anterosuperior and posteroinferior lateral border. Hounsfield Units (HU) were extracted from voxels corresponding to trabecular bone within each ROI. Overall bone density was summarised as the frequency of HU values above 80% of the ROI's maximum density value. Paired, two-tailed t-tests assuming unequal variance were used for pairwise comparisons (P≤0.05). Intra-region analyses compared two ROIs within the same broad anatomical structure; inter-region analyses compared ROIs between anatomical structures. Areas of the spine and lateral border of the scapula appeared to be denser than the coracoid process. Intra-region comparisons indicated no significant differences within ROI: coracoid P=0.43, spine P=0.95, lateral border P=0.41. ROI inferior to the suprascapular notch were on average 3.78% (P=0.08) and 6% (P=0.04) less dense than the anterosuperior and posteroinferior lateral border and 7.59% (P=0.006) and 7.72% (P=0.01) less dense than the anterior and posterior lateral spine. ROI lateral to the suprascapular notch were 6% (P=0.05) and 8.21% (P=0.02) less dense than the anterosuperior and posteroinferior lateral border and 9.8% (P=0.006) and 9.94% (P=0.008) less dense than the anterior and posterior lateral spine. There was no significant difference between the anterior spine and anterosuperior and posteroinferior lateral border (P=0.12, P=0.58), nor between the posterior spine and anterosuperior and posteroinferior lateral border (P=0.14, P=0.57). Results from this study indicate that the spine and lateral border of the scapula contain denser trabecular bone relative to regions in the coracoid. The higher quality bone of the spine and lateral border should be favoured over the coracoid process when fixing the glenoid baseplate in RSA. Further research may support the redesign of the glenoid baseplate geometry to better integrate the anatomy of the scapula and improve implant survival


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 3 - 3
1 Dec 2013
Alta T de Toledo JM Loss JF Janssen TW Van der Scheer J Veeger D( Willems WJ
Full Access

Background:. It is not well known how different external loads influence shoulder kinematics and muscle activity in patients with shoulder prostheses. Study objective: define shoulder kinematics and determine the scapulothoracic contribution to total shoulder motion, in combination with shoulder muscle activity and the degree of co-contraction, of patients with total (TSA) and reverse shoulder arthroplasties (RSA) and healthy individuals during rehabilitation exercises using different loading conditions. Methods:. Shoulder motions (anteflexion and elevation in the scapular plane) of 17 patients (20 shoulders) with a TSA, 8 patients (9 shoulders) with a RSA and 15 healthy subjects were measured using anelectromagnetic tracking device. A force transducer recorded force signals during loaded conditions (without external load, 1 kg and elastic resistance). Electromyographic (EMG) activity of the deltoid (anterior, middle, posterior parts), latissimus dorsi, pectoralis major (clavicular and sternal parts), teres major and serratus anterior was recorded and the degree of co-contraction calculated. Results:. The scapula contributed more to movement of the arm in subjects with prostheses compared to healthy subjects and during loaded versus unloaded tasks. Glenohumeral elevation angles during anteflexion were significantly higher in the TSA than in the RSA group. Higher activity of the middle and posterior deltoid was found in the TSA group compared to healthy subjects and for the pectoralis major (sternal part) in the RSA group compared to TSA and healthy subjects. For all muscles, except the serratus anterior, activity was lower for unloaded tasks compared to 1 kg dumbbell and elastic band resistance. No main effect of group or load for degree of co-contraction was detected in both exercises. Conclusions:. Differences in contribution of the scapula to total shoulder motion between patients with different types of arthroplasties were not significant, but differed both compared to healthy subjects. Scapular kinematics of patients with shoulder arthroplasties were influenced by implementation of external loads, however, not by the type of load. There were no differences in muscle activity and degree of co-contraction between patient groups


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 55 - 55
1 Jan 2013
Ramasamy V Devadoss V
Full Access

Reverse shoulder arthroplasty (RSA) is increasingly performed recently. The patients seeking internet as a source of information may get misleading and a false sense of expectation. This study aimed at analysing patient information on internet and establish list of available quality websites to safely recommend to the patients. The study analysed 310 websites from 10 top search engines exploring the quality of patient information using an assessment tool. Search engines used were metasearch (Metacrawlers and Mamma), general search (Google, Altavista, Yahoo, MSN, AOL, Lycos) and health search engines (Medhunt and Excite Health). The study was undertaken by two independent researcher over a four-week period in November 2011. Each Website was evaluated according to RSA-specific content using a point value system with shoulder disease and surgery specific key words on an ordinal scale. Adequacy of the content was analysed in regard with description of diagnosis, procedure, alternate options, postoperative protocol, complications and prognosis. Excluding the repetitions 104 websites were analysed for accessibility, relevance, authenticity, adequacy of patient information and accountability. The median time since update was 12 months. More than 90% of the websites were found to be of poor quality. Only 25% sites targeted mainly people with shoulder problems. 8% of websites were from non profit organisations. Most of these websites were promoting either their service 80 (76%) or some product 12 (11%). The strength of association between two reviewers was very high (r = 0.899). Intra-rater reliability was significant (r = 0.955) with p level < 0.01. The reading level of most of websites were too high for average consumers. There is need for government organizations and professional societies to regulate the information provided by Internet. Until long-term data are available, patients should be warned when using the Internet as a source for health care information


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 43 - 43
1 May 2016
Bischoff J Wernle J Marra G Verborgt O
Full Access

Introduction. Good outcomes in reverse shoulder arthroplasty (RSA) rely in part on stability of the humeral component. Traditionally humeral components have been cemented, however there has been recent interest in press-fit fixation of humeral components in RSA. Lateralization of the head center in RSA can impart larger moments on the humeral component than for anatomic reconstructions, increasing the importance of distal humeral canal preparation for implant stability. To date, the primary stability of any type of press-fit humeral prosthesis has been largely unexplored. The goal of this study is to evaluate the effect of over-reaming the distal humeral canal in a press-fit humeral component in RSA. Methods. Computed tomography (CT) data of the shoulder were obtained from 55 shoulders. Images were segmented to produce digital models of the humerus. Humeral components for RSA (2mm diameter size increments) were sized and placed per the surgical technique, including preparation of the humerus with the appropriate reamers (1mm increments). Finite element models for each specimen were created with heterogeneous bone properties derived from the CT scan. Pressfit between the bone and stem was resolved to quantify the initial contact pressure on the stem; each stem was then loaded at 566N oriented 20° lateral and 45° anterior. Overall motion of the stem was measured, as well as interfacial micromotion in the porous coating region (Fig. 1). The effect of line-to-line (L2L) reaming and over-reaming by 1 mm was evaluated using an unpaired Student's t-test, with significance defined at p<0.05. Results. Across all specimens, stem sizes 8 (n=3), 10 (n=25), 12 (n=20), 14 (n=2), and 16 (n=1) were used. Stem motion ranged from approximately 250–750μm; micromotion remained under 300μm (Fig. 2). Stem motion was significantly less for L2L reaming as compared to over-reaming for both size 10 (p=.008) and size 12 (p=.002) stems; micromotion was significantly less for size 12 (p=.002) stems. L2L reaming to a larger diameter stem resulted in significantly reduced stem motion (average 390μm versus 530μm, p<.001) and micromotion (average 53μm versus 135μm, p=.001) than over-reaming and using a smaller diameter stem. Stem rotation following L2L reaming was generally below 0.5°, and exceeded 0.75° when over-reaming. Discussion and Conclusion. Reaming of the humeral canal directly impacts the stability of humeral stems in RSA. Even with satisfactory proximal press-fit, over-reaming enables increased rotation of the stem under functional loading prior to cortical engagement, and results in increased micromotion. In cases in which the reamer and stem offerings result in over-reaming, L2L reaming to the next larger stem significantly reduces stem motion and micromotion. However, reaming up also removes distal cortical bone, and thus the strength of the prepared humerus must be considered. In conclusion, line-to-line reaming significantly reduces the micromotion of humeral stems as compared to over-reaming


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 463 - 463
1 Nov 2011
Walker D Cleppe H Sahajpal D Wright T Banks S
Full Access

Reverse shoulder arthroplasty (RSA) is increasingly utilized to restore shoulder function in patients with osteoarthritis and rotator cuff deficiency. There is currently little known about shoulder function after RSA or if differences in surgical technique or implant design affect shoulder performance. The purpose of this study was to quantify scapulohumeral rhythm in patients with RSA during loaded and unloaded shoulder abduction. Eleven patients with RSA performed shoulder abduction (elevation and lowering) with and without a handheld 3kg weight during fluoroscopic imaging. Three RSA designs were included. We used model-image registration techniques to determine the 3D position and orientation of the implants. Cubic curves were fit to the humeral elevation as a function of the scapular elevation over the entire motion. The slope of this curve was used to determine the scapulohumeral rhythm (SHR). For abduction above 40°, shoulders with RSA exhibited an average SHR of 1.5:1. There was no significant difference in SHR between shoulder abduction with and without 3kg handheld weights (1.6±0.2 unweighted vs. 1.4±0.1 weighted), nor was there a significant difference between elevation and lowering. SHR was highly variable for abduction less than 40°, with SHR ranging from a low of 1 to greater than 10. For these very small groups, there was no apparent pattern of differences between implant designs having differing degrees of lateral offset. At arm elevation angles less than 40°, SHR in RSA shoulders is highly variable and the mean SHR (2–5) with RSA appears higher than SHR in normal shoulders (2–3). At higher elevation angles, SHR in shoulders with RSA (1.5–1.8) is much more consistent and appears lower than SHR in normal shoulders (2–4). With the small subject cohort, it was not possible to demonstrate differences between subjects with different implant designs. Ongoing analysis of reverse shoulder function with larger cohort sizes will allow us to refine our observations and determine if there are differences in shoulder function due to implant design, preoperative condition and rehabilitation protocols


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 221 - 221
1 Mar 2010
Young S Turner P Everts N Segal B Poon P
Full Access

Treatment of complex proximal humeral fractures remains controversial. In situations where accurate fracture reduction and fixation cannot be obtained, arthroplasty may be the preferred surgical option. The traditional operation of hemiarthroplasty in these situations is technically challenging, and a good functional outcome is dependent on reduction and healing of the tuberosities. Reverse Shoulder Arthroplasty (RSA) has been suggested as an alternative, and we sought to analyse and compare functional outcomes following the two procedures. Ten patients who underwent hemiarthroplasty for acute fracture of the proximal humerus between 1999 and 2003 were reviewed. All fractures were assessed intraoperatively for open reduction and internal fixation of the fracture, but deemed to be unsuitable for fixation. From 2003 our management in this clinical situation changed, and ten subsequent patients underwent reverse shoulder arthroplasty using the S.M.R. reverse shoulder prosthesis (Systema Multiplana Randell, Lima, Italy). Clinical and radiological follow up was carried out at a mean of 31 months (hemiarthroplasty patients) and 15 months (RSA patients) post operatively. Subjectively seven of 10 patients in the reverse group and seven of 10 patients in the hemiarthroplasty group rated their outcome as ‘very good’ or ‘excellent’. The mean ASES scores were 65 (range 40–88) in the reverse group and 67 (26–100) in the hemiarthroplasty group. The mean Oxford shoulder score was 29 (15–56) in the reverse group and 22 (12–34) in the hemiarthroplasty group. The mean active forward elevation in the hemiarthroplasty group was 108° (range 50–180) and in the reverse group 115° (45–40), and active external rotation 49° (5–105) and 48° (10–90) respectively. Differences in outcome scores between the two groups were not statistic ally significant (p value> 0.05). This study provides the first direct comparison between RSA and hemiarthroplasty for complex proximal humeral fractures. The expected functional gains with Reverse shoulder arthroplasty were not seen, suggesting its use as the primary treatment for acute fracture should remain guarded


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 22 - 22
1 Dec 2013
Frankle M Cabezas A Gutierrez S Teusink M Santoni B Schwartz D
Full Access

Background:. Currently, there are a variety of different reverse shoulder implant designs but few anatomic studies to support the optimal selection of prosthetic size. This study analyzed the glenohumeral relationships of patients who underwent reverse shoulder arthroplasty (RSA). Methods:. Ninety-two shoulders of patients undergoing primary RSA for a massive rotator cuff tear without bony deformity or deficiency and 10 shoulders of healthy volunteers (controls) were evaluated using three-dimensional CT reconstructions and computer aided design (CAD) software. Anatomic landmarks were used to define scapular and humeral planes in addition to articular centers. After aligning the humeral center of rotation with the glenoid center, multiple glenohumeral relationships were measured and evaluated for linearity and size stratification. The correction required to transform the shoulder from its existing state (CT scan) to a realigned image (CAD model) was compared between the RSA and control groups. Size stratification was verified for statistical significance between groups. Generalized linear modeling was used to investigate if glenoid height, coronal humeral head diameter and gender were predictive of greater tuberosity positions. Results:. All 92 shoulders were grouped into three different categories based on glenoid height. The humeral head size, glenoid size, lateral offset, and inferior offset all increased linearly (r. 2. > 0.95), but the rate of increase varied (slopes range from 0.59 to 1.9). Translations required to normalize the shoulder joint were similar between healthy and pathologic cases except for superior migration. Glenoid height, coronal humeral head diameter and gender predicted the greater tuberosity position within 1.09 ± 0.84 mm of actual position in ninety percent of the patient population. Morphometric measurements for each stratified group were all found to be statistically significant between groups (p ≥ 0.05). Conclusion:. Patients who undergo RSA with minimal bony deformity have superior subluxation of the glenohumeral joint. Predicting the anatomic position of the greater tuberosity is dependent on gender, glenoid height and coronal humeral head diameter. This anatomic data provides a guide to avoid inadvertent mismatch of prosthetic and patient shoulder size. If the surgeon is able to measure glenoid height and coronal humeral head diameter preoperatively, accurate planning of the position of the greater tuberosity can be accomplished


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 202 - 202
1 May 2011
Favard L Falaise V Levigne C
Full Access

Background: The orientation and the position of glenoid are two factors which have been pointed out as a cause of notch in case of reverse shoulder arthroplasty (RSA). Our hypothesis is that the notch is mostly depending on the relationship between the humerus and the glenoid. Material and method: The inclusion criteria of this prospective study were: RSA with a 2 years minimum follow up, pre and post op x-rays of good quality to allow accurate measurements, a minimum of 3 x-rays regularly separated in the first 2 years. On these x-rays, done at rest, we have analyzed: the vertical orientation of the glenoid, the degree of abduction of the humerus, the gleno-metaphyseal angle (GMA) which represents the relationship between glenoid and humerus. Sixty one shoulders in 60 patients (57 females, 7 males) have been included. The mean age was 74,6 y.o (56–82) and the mean body mass index (BMI) was 25,4 (16–36). Results: The patients with a notch had a significant correlation with a lower BMI (p< 0,001), a more upward pre op orientation of glenoid (p< 0,01), a less downward post op orientation of the glenoid, a lower degree of abduction of the humerus (p< 0,01), a lower GMA (p< 0,001) that means either that the humerus is less abducted or that the glenoid is orientated more upward or both. In addition we found a strongly correlation between the BMI and the degree of abduction of humerus which is lower if the BMI is low (p< 0,001). We studied the evolution of the angles and we noted that there was no difference during the first 3 months. After 3 months, the GMA stayed stable in patients without notch but was decreasing during the first year in those with a notch. Discussion: The occurrence of a notch is strongly increased in patients with a lower BMI because of a less degree of abduction of the humerus, mostly if the glenoid is orientated upward. So the relationship between humerus and glenoid is more important to analyse than position of glenoid alone. The BMI is another important factor to take into account in case of indication of RSA because the risk of occurrence of a notch is quite higher


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 184 - 184
1 Dec 2013
Frankle M Teusink M Otto R Cottrell B
Full Access

Background:. While reverse shoulder arthroplasty (RSA) has shown successful outcomes for a variety of shoulder pathologies, postoperative scapula fractures continue to be one of the most common complications limiting outcomes with rates reported between 0.8–7.2%. Previous literature has shown that postoperative scapula fractures have a deleterious effect on elevation and outcomes scores, however these studies were all performed at short-term follow-up from the fracture. It has also not been shown whether postoperative scapular fractures increases risk of revision surgery. The purpose of this study was to determine the effect of postoperative scapula fracture on the outcomes following RSA at minimum 1 year follow-up from the fracture. Methods:. A retrospective, case-control study of 25 nonoperatively treated postoperative scapula fractures following RSA in a single surgeon's practice was analyzed with minimum 2 year follow-up from surgery and 1 year follow-up from fracture. Patients with postoperative scapula fractures were matched 1: 4 to a control group for age, sex, total follow-up time, indication for surgery, and primary versus revision surgery. Outcome measures including revision surgery, ASES score, and change in range of motion were compared between fracture cases and controls. Radiographic features including fracture location (acromion vs. scapular spine) and healing of fracture was also analyzed with respect to outcome. Results:. The incidence of postoperative scapula fracture following RSA in this series was 3.1% (32/1018). Fractures occurred from 1–94 months postoperatively, at an average of 16 months. Revision rate was higher in the fracture group (8%, 2/25) than in controls (2%, 2/100) but did not reach statistical significance (p = 0.18). Patients with fractures had inferior clinical outcomes with a postoperative ASES score of 58.0 compared to 74.2 in controls (p = 0.001), but were clinically improved from preoperative scores with an average improvement of 21 points. Improvement in range of motion was also decreased in the fracture group with a mean gain of forward elevation of 26° compared to 76° in controls (p < 0.001). Fracture location (acromion versus scapular spine) (p = 0.54) or healing (p = 0.40) did not affect outcome. Conclusion:. Postoperative scapula fractures may occur at any point during the postoperative period therefore increasing incidence is likely as longer follow-up becomes available. This complication leads to inferior clinical results compared to controls, however patients show improvement compared to their preoperative measurements, even at longer term follow-up. Patients sustaining postoperative scapula fractures may have increased risk of revision surgery


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 343 - 343
1 May 2010
Boileau P
Full Access

Introduction: The reverse shoulder arthroplasty (RSA) is becoming increasingly common and the indications expanded. The objective of this study is to report the indications and results of RSA in a large multicenter study. Methodology: A retrospective, multicenter study was conducted including all RSA implanted between 1992 and 2002 in five centers in France. Of 457 patients involved in this study, 243 patients (53%) had cuff pathology: 149 had cuff tear arthropathy, 48 had massive cuff tears, and 45 had failed cuff surgery. Ninety-nine (22%) had revision of previous prostheses. Sixty (13%) had fracture-related problems. Twenty-six (6%) had osteoarthritis and two percent each had rheumatoid arthritis, tumors or other conditions. Three hundred and eighty-nine (85%) shoulders were available for review with greater than 2 years follow-up. The average age at review was 75.6 years (range, 22–92). The average follow-up was 43.5 months (range, 24–142). Results: Significant improvement was noted in Constant scores for pain (3.5 to 12.1), activity (5.8 to 15.1), mobility (12.1 to 24.5), and strength (1.3 to 6.1) (p< .0001). Active elevation improved, but active internal and external rotation did not. The results were dependent on the indication. Cuff tear arthropathy had the best results while revision procedures had the worst. Young age, preoperative stiffness, teres minor deficiency, tuberosity non-union and preoperative complaints of pain rather than loss of function tended to be associated with inferior results. The deltopectoral approach tended toward greater active elevation but greater risk of instability. Survivorship to the endpoints of revision and loosening was better for patients with rotator cuff problems than for patients with failed prior hemiarthroplasty. The functional results were noted to deteriorate progressively after six years in the cuff tear group, after five years in the revision hemiarthroplasty group, after three years in the osteoarthritis group, and after one year in the revision total shoulder arthroplasty group. Conclusions: The overall results of RSA are satisfactory and predictable. Functional results improved with improved active elevation, but no improvement in active internal and external rotation. However, results are dependent on the etiology


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 33 - 33
1 Mar 2010
Bicknell RT Chuinard C Boileau P
Full Access

Purpose: The reverse shoulder arthroplasty (RSA) is becoming increasingly common and the indications expanded. The objective of this study is to report the indications and results of RSA in a large multicenter study. Method: A retrospective, multicenter study was conducted including all RSA implanted between 1992 and 2002 in five centers in France. Of 457 patients involved in this study, 243 patients (53%) had cuff pathology: 149 had cuff tear arthropathy, 48 had massive cuff tears, and 45 had failed cuff surgery. Ninety-nine (22%) had revision of a previous arthroplasty. Sixty (13%) had fracture-related problems. Twenty-six (6%) had osteoarthritis and two percent each had rheumatoid arthritis, tumors or other conditions. Three hundred and eighty-nine (85%) shoulders were available for review at a mean follow-up of 44 months (range, 24–142). The average age at review was 76 years (range, 22–92). Results: Overall, significant improvement was noted in Constant scores for pain (3.5 to 12.1), activity (5.8 to 15.1), mobility (12.1 to 24.5) and strength (1.3 to 6.1) (p< 0.0001). Active elevation improved (p< 0.0001), but active internal and external rotation did not. The results were dependent on the indication. Cuff tear arthropathy had the best results while revision procedures had the worst. Young age, preoperative stiffness, teres minor deficiency, tuberosity non-union and preoperative complaints of pain rather than loss of function tended to be associated with inferior results. The deltopectoral approach tended toward greater active elevation but greater risk of instability. Survivorship to the endpoints of revision and loosening was better for patients with cuff tear pathology than for patients with failed prior hemiarthroplasty. The functional results were noted to deteriorate progressively after six years in the cuff tear pathology group, after five years in the revision hemiarthroplasty group, after three years in the osteoarthritis group, and after one year in the revision total shoulder arthroplasty group. Conclusion: Overall results of RSA are satisfactory and predictable. Functional results improved with improved active elevation, but no improvement in active internal and external rotation. However, results are dependent on etiology


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 34 - 34
1 Mar 2010
Bicknell RT Matsen F Walch G Nové-Josserand L
Full Access

Purpose: Reverse shoulder arthroplasty (RSA) is becoming increasingly common for a variety of indications. The most common postoperative complication is instability. The objectives of this study are to describe causes of RSA instability and preventive and treatment recommendations. Method: All members of the American Shoulder and Elbow Society were asked for cases of RSA instability. We retrospectively reviewed 52 cases in 52 patients, performed by 13 surgeons. The mean age was 67.5 years (range, 36–83). The mean follow-up was 32.7 months (range, 3–43). Results: The etiology included: cuff tear arthropathy (14 patients); revision arthroplasty (13 patients); fracture sequelae (6 patients); and other (6 patients). Twenty-four patients had previous shoulder surgery. All patients had a deltopectoral approach. Anterior deltoid deficiency was noted in 3 cases. Subscapularis insufficiency was noted in 27 cases. Humeral component dissociation occurred in 2 patients. The instability was: anterior (27 patients); posterior (5 patients); or inferior (3 patients). Instability occurred: in the first 48 hours (10 cases); between 2 to 30 days (13 cases); or after one month (12 cases). Causes of instability included: inadequate soft-tissue tension (23 patients); a large antero-inferior release (22 patients); subscapularis insufficiency (7 patients); hematoma (2 patients); trauma (2 patients), deltoid insufficiency (2 patients); glenosphere malposition (2 patients); acromion fracture (2 patients); and other (4 patients). Initial treatment included: non-operative (6 patients); closed reduction (23 patients); open reduction (3 patients); and revision arthroplasty (11 patients). Final outcomes included: persistent instability (7 patients); humeral revision (19 patients); glenoid revision (one patient); hemiarthroplasty (3 patients); and resection arthroplasty (2 patients). Conclusion: Main causes of RSA instability include inadequate soft tissue tension, large anteroinferior release and subscapularis insufficiency. Preventive measures include careful patient selection, restoration of humeral length, minimizing anteroinferior releases, maximizing soft-tissue tension, maintaining or restoring subscapularis integrity, immobilization in the case of subscapularis insufficiency and use of a postoperative drain. Treatment recommendations include restoration of humeral length, soft-tissue retensioning and prolonged immobilization


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 147 - 147
1 Dec 2013
Pappou MFI Virani N Clark R
Full Access

Background:. The rising number of morbidly obese patients may have significant consequences on the health care system. It may alter the effectiveness, safety as well as cost of certain surgical procedures. Reverse shoulder arthroplasty (RSA) is rapidly gaining in popularity. We investigated the effect of morbid obesity on outcomes, complications, disposition and cost in morbidly obese patients undergoing RSA in a 1: 3 case control series. Methods:. Our joint registry was searched for all patients undergoing primary RSA (excluding fractures) with a minimum of 24 months follow-up from 2003–2010; 21 patients with Body Mass Index (BMI) > 35 were identified (follow-up 45 ± 16 months, 17 females and 4 males, age 69 ± 7) and compared to 63 matched control patients with BMI<30 (follow-up 48 ± 20, 50 females, age 71 ± 6). Outcome data was obtained pre- and postoperatively. Patients' Charlson-Deyo comorbidity index (CDI), total comorbidities, operative time, blood loss (EBL), hospitalization length, disposition, cost and complications were recorded. Results:. There were significant (p < 0.05 for all) and comparable improvements in clinical outcomes, i.e. ASES 32→69 versus 40→78) and range-of-motion (i.e. elevation 61°→140° versus 74°→153°). Obese patients had less notching (1/21 versus 5/63, p = 0.007). Obese patients had more total comorbidities excluding obesity (6 versus 4, p = 0.001), higher CDI (2 versus 1, p = 0.025) and higher rates of obstructive sleep apnea (48% versus 3%, p = 0.0001). They had longer operative time by 13 minutes (p = 0.014) and higher EBL by 40 ml (p = 0.008). Length of stay was similar (3.1 versus 2.6 days, p = 0.21) but a 6-fold higher rate of discharge to facilities (6/21 versus 3/63, p = 0.007) and a higher readmission rate (2 versus 0, p = 0.06) was seen in obese patients. Hospital cost was higher by $2,958.00 (p = 0.02). Major (n = 4 versus 8) and minor complication rates (n = 3 versus 14) were similar (p = 0.479 and 0.440, respectively). No intraoperative complications or mechanical device failures were noted in either group. Conclusions:. RSA was as safe and effective in morbidly obese patients, but an increased cost, disposition to facilities and needs after discharge was observed


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 59 - 59
1 Dec 2013
Schwartz D Cottrell B Teusink M Clark R Downes K Frankle M
Full Access

Introduction:. Reverse shoulder arthroplasty (RSA) has proven to be a useful tool to manage a variety of pathologic conditions. However, inconsistent improvement in motion occurs in patients who have undergone RSA for revision shoulder arthroplasty, proximal humeral fracture sequelae, and treatment of infection. Additional factors that have been suggested to produce poor postoperative range of motion (ROM) may be associated with patient's factors such as poor preoperative range of motion and surgical factors such as inability to lengthen the arm. The purpose of this study was to analyze multiple factors which may be responsible in predicting motion after RSA. It is our hypothesis that intraoperative ROM is most predictive of postoperative ROM. Methods:. Between February 2003 and April 2011 566 patients (225 male and 341 female) treated with a RSA for 1) acute proximal humeral fracture (11), 2) Sequeala of proximal humeral fractures (31), 3) cuff tear arthropathy (278), 4) massive cuff tear without arthritis (78), 5) failed shoulder arthroplasty (168) and 6) infection (29) were evaluated with preoperative range of motion, intraoperative range of motion and range of motion at a minimum of 2-year postoperative follow up. A single observer recorded intraoperative flexion (IFF) in 30° increments. Preoperative and postoperative ROM was recorded by patient video or a previously validated patient performed outcome measure. Preoperative diagnosis was confirmed by radiographic and intraoperative information. 477 patients had preoperative and postoperative radiographs available for analysis of acromial-greater tuberosity distance change (AGT) which was utilized to calculate arm lengthening. A regression analysis was then performed to determine which factors were most influential in predicting postoperative active range of motion. Results:. IFF was the strongest predictor of final postoperative ROM, followed by gender and preoperative ROM. Age, AGT and treatment for the purposes of revision, infection or massive cuff tear were not significant independent predictors of postoperative ROM. Compared to patients with intraoperative forward elevation of ≤60 degrees, patients with intraoperative elevation of 90 degrees gained 16° in postoperative forward elevation (p = 0.029), patients with intraoperative elevation of 120 degrees gained roughly 38° in postoperative forward elevation (p < 0.001) and patients with intraoperative elevation of 150 degrees gained roughly 49 degrees in postoperative forward elevation (p < 0.001). Patients with 120° or more intraoperative elevation were nine times more likely (OR = 9.04, 95%CI: 4.96–16.47) than patients with 90° or less intraoperative elevation to have postoperative forward elevation of 150° or more (top 25% of postoperative results). Conclusions:. Intraoperative forward flexion is strongest predictor postoperative ROM. Surgeons are able to use intraoperative motion as a powerful tool in decision making regarding soft tissue tension in reverse shoulder arthroplasty, therefore by maximizing intraoperative motion, patients have a much greater likelihood of improvement in their final active motion


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 265 - 265
1 Mar 2013
Miyoshi N Suenaga N Oizumi N Taniguchi N Ito H
Full Access

Introduction. In recently, Reverse shoulder arthroplasty (RSA) in patients with irreparable rotator cuff tear has been worldwidely performed. Many studies on RSA reported a good improvement in flexion of the sholulder, however, no improvement in external rotation (ER)and internal rotation motion (IR). Additionally, RSA has some risks to perform especially in younger patients, because high rates of complications such as deltoid stretching and loosening, infection, neurologic injury, dislocation, acromial fracture, and breakage of the prosthesis after long-term use were reported. Favard et al noted a 72% survival with a Constant-Murley score of <30 at 10 years with a marked break occurring at 8 years. Boileau et al noted caution is required, as such patients are often younger, and informed consent must obviously cover the high complication rate in this group, as well as the unknown longer-term outcome. Its use should be limited to elderly patients, arguably those aged over 70 years, with poor function and severe pain related to cuff deficiency. We developed a novel strategy in 2001, in which we used the humeral head to close the cuff defect and move the center of rotation medially and distally to increase the lever arm of the deltoid muscle. Aim. The aim of this study was to investigate clinical outcome of our strategy for younger patients with an irreparable rotator cuff tear. Materials and Methods. Eighteen shoulders (9 of male patients, 9 of female patients) of patients under 70 years old with an irreparable cuff tears and who were treated with Humeral Head Replacement (HHR) and cuff reconstruction were followed up for more than 12 months. The average age was 63.9 years (range, 58–69 years). The average follow-up period was 27.3 months (range, 12–76 months). The cuff defect was successfully closed in 8 shoulders, whereas 8 shoulders required a Latissimus Dorsi transfer; one other shoulder required a Pectralis Major transfer, and one required both Latissimus dorsi and pectoralis major transfers. Range of motion (flexion, ER), the shoulder score of Japanese Orthopaedic Association (JOA score), and complications were evaluated. Results. Shoulder pain decreased in all patients after surgery. JOA score was improved from 41.1 to 82.6 points after surgery, Flexion motion improved from 72.5 to 145.6 degrees postoperatively and ER increased from 17.5 to 37.8 degrees postoperatively. There were no complications. Conclusion. In our study, HHR using the small head of the humerus and cuff reconstruction for patients under 70 years old with an irreparable rotator cuff tear yielded favorable results as compared to RSA, especially in terms of the ER Furthermore, the advantages of our strategy is able to keep bone stock of the glenoid after surgery. If revision surgery is required, RSA can be performed. Since the patients included in our study were relatively active, long-term follow-up will be required to assess their progress


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 246 - 246
1 May 2009
Bicknell R Boileau P Chuinard C Garaud P Neyton L
Full Access

The purpose was to evaluate the results of reverse shoulder arthroplasty (RSA) in proximal humerus fracture sequelae (FS). Multicenter retrospective series of forty-five consecutive patients operated between 1995 and 2003. Types of FS included: cephalic collapse and necrosis (n=8), chronic locked dislocation (n=5), surgical neck nonunion (n=7), severe malunion (twenty), and isolated greater tuberosity malunion (n=3). Twenty-six patients had surgical treatment of the initial fracture and seventeen had non-surgical treatment; thirty-three Delta and ten Aequalis reverse prosthesis were implanted. Mean age at surgery was seventy-three years (range, fifty-seven to eighty-six). Forty-three patients were available for clinical and radiologic evaluation with a mean follow-up of thirty-nine months (range, twenty-four to ninety-five). Nine re-operations (21%) and ten complications (23%) were encountered, including four infections (leading to two resection-arthroplasties), two instabilities, one glenoid fracture (converted to hemiarthroplasty) and one axillary nerve palsy. Thirty-six patients (83%) were satisfied or very satisfied with their result. The adjusted Constant score improved from 29% preoperatively to 75% postoperatively (p< 0.0001), the Constant score for pain from fou to twelve points (p< 0.0001), and active anterior elevation from 59° to 114° (p< 0.0001). Active rotations were limited. A positive postoperative hornblower test negatively influenced Constant score (forty-two points compared to 61.5 points, p=0.004) and external rotation (−6° compared to 15°, p=0.004). The lowest functional results were observed in surgical neck nonunions (with five complications) and isolated greater tuberosity malunions. In type four fracture sequelae, patients who had an osteotomy or resection of the GT (n=9) had better forward flexion (140° compared to 110°, p=0.026) and better Constant score (sixty-three points compared to forty-six points, p=0.07). RSA can be a surgical option in elderly patients with FS, specifically for those with severe malunion (type four fracture sequelae) where hemiarthroplasty gives poor results. By contrast, surgical neck nonunions (type three) and isolated greater tuberosity malunions are at risk for low functional results. The surgical technique and the remaining cuff muscles (teres minor) are important prognostic factors. Functional results are lower and complications/reoperations rates are higher than those reported for RSA in cuff tear arthritis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 147 - 147
1 Sep 2012
Alami GB Boileau P
Full Access

Purpose. While treating fracture sequelae (FS) with unconstrained prostheses has been shown to give inferior or unpredictable outcomes, the literature is still scant regarding their treatment with reverse shoulder arthroplasty (RSA). This study was performed to determine the suitability of RSA as a solution for FS with severe tuberosity malunion/nonunion and rotator cuff dysfunction, and to identify any useful preoperative prognostic factors. Method. Between 1997 and 2007, RSA was performed in 26 cases for FS of type 4 according to the classification of Boileau et al., previously treated either operatively or nonoperatively. Prior treatment with hemiarthroplasty was an exclusion criteria, as was follow-up of less than two years, leaving 20 patients who had undergone an average of one surgery prior to the index RSA (range, 1–3) and were followed up for a mean of 4.8 years. Preoperatively, the mean global fatty degeneration index (GFDI) was 1.8 (range, 0.7–2.9), and almost half the patients had an atrophic or ruptured teres minor. The mean age at surgery was 70 years (range, 50–91). Clinical evaluation was performed by two independent observers with the help of the Constant score (CS) and Subjective Shoulder Value (SSV). Results. Three patients (15%) had five complications, all of which were treated with reoperation. No infections and only one case of instability occurred. Overall, 82% were satisfied or very satisfied, and the mean relative CS improved by 45% (from 35% to 80%). The best range-of-motion gains were made in active anterior elevation, which improved by 53 (from 62 to 115), although gains were generally variable. Teres minor and subscapularis insufficiency was observed in many patients. Worse clinical outcomes were associated with these preoperative variables: prior surgical treatment, medical comorbidity, a lack of active external rotation, and a GFDI of 2.0 or more. However, the numbers available did not produce statistically significant correlations. Radiographic humeral-component loosening was seen in one patient (5%), and either the humeral or the glenoid component was considered at-risk in three patients (15%), although no revisions were performed for loosening. Conclusion. These results show that in the medium term, RSA is a very good treatment option for elderly patients with severe FS and rotator cuff dysfunction. They are better than previously published results of RSA performed for FS but not as good as those of RSA for CTA. High satisfaction rates may be related to the severity of preoperative disability and good patient education. The association of prior surgical treatment with worse results may be related to the negative effect of surgery on the rotator cuff and anterior deltoid. Much can be learned from the reported complications, and outcomes will probably improve with improved prosthetic design and surgical techniques, as well as with better surgeon and patient awareness of the surgical pitfalls and variable clinical gains, especially in rotation


Bone & Joint Open
Vol. 4, Issue 8 | Pages 567 - 572
3 Aug 2023
Pasache Lozano RDP Valencia Ramón EA Johnston DG Trenholm JAI

Aims

The aim of this study is to evaluate the change in incidence rate of shoulder arthroplasty, indications, and surgeon volume trends associated with these procedures between January 2003 and April 2021 in the province of Nova Scotia, Canada.

Methods

A total of 1,545 patients between 2005 and 2021 were analyzed. Patients operated on between 2003 and 2004 were excluded due to a lack of electronic records. Overall, 84.1% of the surgeries (n = 1,299) were performed by two fellowship-trained upper limb surgeons, with the remainder performed by one of the 14 orthopaedic surgeons working in the province.


Bone & Joint 360
Vol. 12, Issue 3 | Pages 27 - 30
1 Jun 2023

The June 2023 Shoulder & Elbow Roundup360 looks at: Proximal humerus fractures: what does the literature say now?; Infection risk of steroid injections and subsequent reverse shoulder arthroplasty; Surgical versus non-surgical management of humeral shaft fractures; Core outcome set needed for elbow arthroplasty; Minimally invasive approaches to locating radial nerve in the posterior humeral approach; Predictors of bone loss in anterior glenohumeral instability; Does the addition of motor control or strengthening exercises improve rotator cuff-related shoulder pain?; Terminology and diagnostic criteria used in patients with subacromial pain syndrome.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 970 - 977
1 Sep 2024
De Rus Aznar I Ávila Lafuente JL Hachem A Díaz Heredia J Kany J Elhassan B Ruiz Ibán MÁ

Rotator cuff pathology is the main cause of shoulder pain and dysfunction in older adults. When a rotator cuff tear involves the subscapularis tendon, the symptoms are usually more severe and the prognosis after surgery must be guarded. Isolated subscapularis tears represent 18% of all rotator cuff tears and arthroscopic repair is a good alternative primary treatment. However, when the tendon is deemed irreparable, tendon transfers are the only option for younger or high-functioning patients. The aim of this review is to describe the indications, biomechanical principles, and outcomes which have been reported for tendon transfers, which are available for the treatment of irreparable subscapularis tears.

The best tendon to be transferred remains controversial. Pectoralis major transfer was described more than 30 years ago to treat patients with failed surgery for instability of the shoulder. It has subsequently been used extensively to manage irreparable subscapularis tendon tears in many clinical settings. Although pectoralis major reproduces the position and orientation of the subscapularis in the coronal plane, its position in the axial plane – anterior to the rib cage – is clearly different and does not allow it to function as an ideal transfer. Consistent relief of pain and moderate recovery of strength and function have been reported following the use of this transfer. In an attempt to improve on these results, latissimus dorsi tendon transfer was proposed as an alternative and the technique has evolved from an open to an arthroscopic procedure. Satisfactory relief of pain and improvements in functional shoulder scores have recently been reported following its use. Both pectoralis minor and upper trapezius transfers have also been used in these patients, but the outcomes that have been reported do not support their widespread use.

Cite this article: Bone Joint J 2024;106-B(9):970–977.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 3 - 5
1 Jan 2022
Rajasekaran RB Ashford R Stevenson JD Pollock R Rankin KS Patton JT Gupta S Cosker TDA


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 150 - 156
1 Jan 2022
Leino OK Lehtimäki KK Mäkelä K Äärimaa V Ekman E

Aims

Proximal humeral fractures (PHFs) are common. There is increasing evidence that most of these fractures should be treated conservatively. However, recent studies have shown an increase in use of operative treatment. The aim of this study was to identify the trends in the incidence and methods of treatment of PHFs in Finland.

Methods

The study included all Finnish inhabitants aged ≥ 16 years between 1997 and 2019. All records, including diagnostic codes for PHFs and all surgical procedure codes for these fractures, were identified from two national registers. Data exclusion criteria were implemented in order to identify only acute PHFs, and the operations performed to treat them.


Bone & Joint Open
Vol. 2, Issue 7 | Pages 552 - 561
28 Jul 2021
Werthel J Boux de Casson F Burdin V Athwal GS Favard L Chaoui J Walch G

Aims

The aim of this study was to describe a quantitative 3D CT method to measure rotator cuff muscle volume, atrophy, and balance in healthy controls and in three pathological shoulder cohorts.

Methods

In all, 102 CT scans were included in the analysis: 46 healthy, 21 cuff tear arthropathy (CTA), 18 irreparable rotator cuff tear (IRCT), and 17 primary osteoarthritis (OA). The four rotator cuff muscles were manually segmented and their volume, including intramuscular fat, was calculated. The normalized volume (NV) of each muscle was calculated by dividing muscle volume to the patient’s scapular bone volume. Muscle volume and percentage of muscle atrophy were compared between muscles and between cohorts.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1491 - 1492
1 Nov 2018
Wagner ER Hevesi M Houdek MT Cofield RH Sperling JW Sanchez-Sotelo J


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 702 - 707
1 Jun 2019
Moeini S Rasmussen JV Salomonsson B Domeij-Arverud E Fenstad AM Hole R Jensen SL Brorson S

Aims

The aim of this study was to use national registry database information to estimate cumulative rates and relative risk of revision due to infection after reverse shoulder arthroplasty.

Patients and Methods

We included 17 730 primary shoulder arthroplasties recorded between 2004 and 2013 in The Nordic Arthroplasty Register Association (NARA) data set. With the Kaplan–Meier method, we illustrated the ten-year cumulative rates of revision due to infection and with the Cox regression model, we reported the hazard ratios as a measure of the relative risk of revision due to infection.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1272 - 1279
1 Oct 2019
Nowak LL Hall J McKee MD Schemitsch EH

Aims

To compare complication-related reoperation rates following primary arthroplasty for proximal humerus fractures (PHFs) versus secondary arthroplasty for failed open reduction and internal fixation (ORIF).

Patients and Methods

We identified patients aged 50 years and over, who sustained a PHF between 2004 and 2015, from linkable datasets. We used intervention codes to identify patients treated with initial ORIF or arthroplasty, and those treated with ORIF who returned for revision arthroplasty within two years. We used multilevel logistic regression to compare reoperations between groups.


Bone & Joint 360
Vol. 9, Issue 2 | Pages 46 - 48
1 Apr 2020
Evans JT Whitehouse MR


Bone & Joint 360
Vol. 7, Issue 5 | Pages 21 - 24
1 Oct 2018


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 365 - 370
1 Mar 2020
Min KS Fox HM Bedi A Walch G Warner JJP

Aims

Patient-specific instrumentation has been shown to increase a surgeon’s precision and accuracy in placing the glenoid component in shoulder arthroplasty. There is, however, little available information about the use of patient-specific planning (PSP) tools for this operation. It is not known how these tools alter the decision-making patterns of shoulder surgeons. The aim of this study was to investigate whether PSP, when compared with the use of plain radiographs or select static CT images, influences the understanding of glenoid pathology and surgical planning.

Methods

A case-based survey presented surgeons with a patient’s history, physical examination, and, sequentially, radiographs, select static CT images, and PSP with a 3D imaging program. For each imaging modality, the surgeons were asked to identify the Walch classification of the glenoid and to propose the surgical treatment. The participating surgeons were grouped according to the annual volume of shoulder arthroplasties that they undertook, and responses were compared with the recommendations of two experts.


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 454 - 460
1 Apr 2019
Lapner PLC Rollins MD Netting C Tuna M Bader Eddeen A van Walraven C

Aims

Few studies have compared survivorship of total shoulder arthroplasty (TSA) with hemiarthroplasty (HA). This observational study compared survivorship of TSA with HA while controlling for important covariables and accounting for death as a competing risk.

Patients and Methods

All patients who underwent shoulder arthroplasty in Ontario, Canada between April 2002 and March 2012 were identified using population-based health administrative data. We used the Fine–Gray sub-distribution hazard model to measure the association of arthroplasty type with time to revision surgery (accounting for death as a competing risk) controlling for age, gender, Charlson Comorbidity Index, income quintile, diagnosis, and surgeon factors.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 318 - 323
1 Mar 2018
Raiss P Alami G Bruckner T Magosch P Habermeyer P Boileau P Walch G

Aims

The aim of this study was to analyze the results of reverse shoulder arthroplasty (RSA) in patients with type 1 sequelae of a fracture of the proximal humerus in association with rotator cuff deficiency or severe stiffness of the shoulder.

Patients and Methods

A total of 38 patients were included: 28 women and ten men. Their mean age at the time of arthroplasty was 73 years (54 to 91). Before the RSA, 18 patients had been treated with open reduction and internal fixation following a fracture. A total of 22 patients had a rotator cuff tear and 11 had severe stiffness of the shoulder with < 0° of external rotation. The mean follow-up was 4.3 years (1.5 to 10). The Constant score and the range of movement of the shoulder were recorded preoperatively and at final follow-up.

Preoperatively, radiographs in two planes were performed, as well as CT or arthro-CT scans; radiographs were also performed at final follow-up.


Bone & Joint 360
Vol. 7, Issue 2 | Pages 2 - 7
1 Apr 2018
Das A Giddie J Ollivere B


Bone & Joint 360
Vol. 6, Issue 4 | Pages 2 - 7
1 Aug 2017
Titchener AG Tambe AA Clark DI


Bone & Joint 360
Vol. 5, Issue 5 | Pages 22 - 25
1 Oct 2016


Bone & Joint Research
Vol. 6, Issue 10 | Pages 590 - 599
1 Oct 2017
Jefferson L Brealey S Handoll H Keding A Kottam L Sbizzera I Rangan A

Objectives

To explore whether orthopaedic surgeons have adopted the Proximal Fracture of the Humerus: Evaluation by Randomisation (PROFHER) trial results routinely into clinical practice.

Methods

A questionnaire was piloted with six orthopaedic surgeons using a ‘think aloud’ process. The final questionnaire contained 29 items and was distributed online to surgeon members of the British Orthopaedic Association and British Elbow and Shoulder Society. Descriptive statistics summarised the sample characteristics and fracture treatment of respondents overall, and grouped them by whether they changed practice based on PROFHER trial findings. Free-text responses were analysed qualitatively for emerging themes using Framework Analysis principles.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1215 - 1221
1 Sep 2016
Verhofste B Decock T Van Tongel A De Wilde L

Aims

Heterotopic ossification (HO) occurs after arthroplasty, especially total hip arthroplasty. In this study we describe the incidence, evolution, morphology and clinical consequences of HO following reverse shoulder arthroplasty.

Patients and Methods

This is a single-centre retrospective study of 132 consecutive patients who received a Delta III or Delta Xtend reverse total shoulder arthroplasty between 2006 and 2013 for the treatment of cuff tear arthropathy. There were 96 women and 36 men. Their mean age at the time of surgery was 69 years (49 to 89) and the mean follow-up was 36 months (12 to 84). The incidence, evolution, morphology and clinical consequences of HO using the Constant-Murley score (CS) were analysed. A modified Brooker classification of HO of the hip was used.


Bone & Joint 360
Vol. 4, Issue 1 | Pages 22 - 24
1 Feb 2015

The February 2015 Shoulder & Elbow Roundup360 looks at: Proximal Humerus fractures a comprehensive review, Predicting complications in shoulder ORIF, The Coronoid Revisited, Remplissage and bankart repair for Hill-Sach’s lesions, Diabetes and elbow arthroplasty, Salvage surgery for failed bankart repair, Sternoclavicular Joint Reconstruction, Steroids effective in the short-term for tennis elbow


Bone & Joint 360
Vol. 2, Issue 5 | Pages 27 - 29
1 Oct 2013

The October 2013 Shoulder & Elbow Roundup360 looks at: Deltoid impairment not necessarily a contra-indication for shoulder arthroplasty; The tricky radiograph; Not so asymptomatic cuff tears; Total shoulder arthroplasty: kinder on the glenoid; Barbotage for calcific tendonitis; What happens to the arthritic glenoid?; Two screws a screw too few?; Sloppy hinge best for elbow arthroplasty.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 936 - 942
1 Jul 2014
Middleton C Uri O Phillips S Barmpagiannis K Higgs D Falworth M Bayley I Lambert S

Inherent disadvantages of reverse shoulder arthroplasty designs based on the Grammont concept have raised a renewed interest in less-medialised designs and techniques. The aim of this study was to evaluate the outcome of reverse shoulder arthroplasty (RSA) with the fully-constrained, less-medialised, Bayley–Walker prosthesis performed for the treatment of rotator-cuff-deficient shoulders with glenohumeral arthritis. A total of 97 arthroplasties in 92 patients (53 women and 44 men, mean age 67 years (standard deviation (sd) 10, (49 to 85)) were retrospectively reviewed at a mean follow-up of 50 months ((sd 25) (24 to 96)). The mean Oxford shoulder score and subjective shoulder value improved from 47 (sd 9) and 24 points (sd 18) respectively before surgery to 28 (sd 11) and 61 (sd 24) points after surgery (p <  0.001). The mean pain at rest decreased from 5.3 (sd 2.8) to 1.5 (sd 2.3) (p < 0.001). The mean active forward elevation and external rotation increased from 42°(sd 30) and 9° (sd 15) respectively pre-operatively to 78° (sd 39) and 24° (sd 17) post-operatively (p < 0.001). A total of 20 patients required further surgery for complications; 13 required revision of components. No patient developed scapular notching.

The Bayley–Walker prosthesis provides reliable pain relief and reasonable functional improvement for patients with symptomatic cuff-deficient shoulders. Compared with other designs of RSA, it offers a modest improvement in forward elevation, but restores external rotation to some extent and prevents scapular notching. A longer follow-up is required to assess the survival of the prosthesis and the clinical performance over time.

Cite this article: Bone Joint J 2014;96-B:936–42.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1106 - 1113
1 Aug 2013
Lädermann A Walch G Denard PJ Collin P Sirveaux F Favard L Edwards TB Kherad O Boileau P

The indications for reverse shoulder arthroplasty (RSA) continue to be expanded. Associated impairment of the deltoid muscle has been considered a contraindication to its use, as function of the RSA depends on the deltoid and impairment of the deltoid may increase the risk of dislocation. The aim of this retrospective study was to determine the functional outcome and risk of dislocation following the use of an RSA in patients with impaired deltoid function. Between 1999 and 2010, 49 patients (49 shoulders) with impairment of the deltoid underwent RSA and were reviewed at a mean of 38 months (12 to 142) post-operatively. There were nine post-operative complications (18%), including two dislocations. The mean forward elevation improved from 50° (sd 38; 0° to 150°) pre-operatively to 121° (sd 40; 0° to 170°) at final follow-up (p < 0.001). The mean Constant score improved from 24 (sd 12; 2 to 51) to 58 (sd 17; 16 to 83) (p < 0.001). The mean Single Assessment Numeric Evaluation score was 71 (sd 17; 10 to 95) and the rate of patient satisfaction was 98% (48 of 49) at final follow-up.

These results suggest that pre-operative deltoid impairment, in certain circumstances, is not an absolute contraindication to RSA. This form of treatment can yield reliable improvement in function without excessive risk of post-operative dislocation.

Cite this article: Bone Joint J 2013;95-B:1106–13.