Aims

The primary aim of this study was to report the radiological outcomes of patients with a dorsally displaced distal radius fracture who were randomized to a moulded cast or surgical fixation with wires following manipulation and closed reduction of their fracture. The secondary aim was to correlate radiological outcomes with patient-reported outcome measures (PROMs) in the year following injury.

Methods

Participants were recruited as part of DRAFFT2, a UK multicentre clinical trial. Participants were aged 16 years or over with a dorsally displaced distal radius fracture, and were eligible for the trial if they needed a manipulation of their fracture, as recommended by their treating surgeon. Participants were randomly allocated on a 1:1 ratio to moulded cast or Kirschner wires after manipulation of the fracture in the operating theatre. Standard posteroanterior and lateral radiographs were performed in the radiology department of participating centres at the time of the patient’s initial assessment in the emergency department and six weeks postoperatively. Intraoperative fluoroscopic images taken at the time of fracture reduction were also assessed.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 139 - 139
1 Feb 2003
O’Shea K McCarthy T Moore D Dowling F Fogarty E
Full Access

Neonatal septic arthritis is a true orthopaedic emergency posing significant threat to life and limb. Objective: To examine the clinical presentation, diagnosis, treatment and outcome of children presenting with septic arthritis in the neonatal period. Design: Retrospective review of clinical notes and radiographs of children presenting over a 20 year period (1977–97). Subjects: 34 patients with septic arthritis in a total of 36 joints. Outcome measures: Clinical outcome was classified as satisfactory or unsatisfactory as per Morrey et al. Radiological outcome was graded I–IV as per Choi et al. Joint instability, destruction, limb length discrepancy and angular deformity were assessed. Results: The hip joint was affected in 24 of the 34 cases. Pseudoparalysis was the most reliable clinical finding occurring in 29 out of 34 cases. Staph Aureus was isolated as the infecting pathogen in 22/34 patients. Sequelae occurred in 16 hips and 1 knee. Poor prognostic indicators were delayed diagnosis (p< 0.05) and the hip as site of infection (p< 0.01). Clinical outcome was unsatisfactory in 15 patients and satisfactory in 17 patients. Radiological outcome was Choi I or IIA (good) in 12 hips and Choi II to IV in 13 hips (poor). Multiple further reconstructive procedures were required in 15 cases. Conclusions: Despite optimum treatment, neonatal septic arthritis results in significant long-term morbidity for a high proportion of cases


Bone & Joint Open
Vol. 2, Issue 3 | Pages 191 - 197
1 Mar 2021
Kazarian GS Barrack RL Barrack TN Lawrie CM Nunley RM

Aims

The purpose of this study was to compare the radiological outcomes of manual versus robotic-assisted medial unicompartmental knee arthroplasty (UKA).

Methods

Postoperative radiological outcomes from 86 consecutive robotic-assisted UKAs (RAUKA group) from a single academic centre were retrospectively reviewed and compared to 253 manual UKAs (MUKA group) drawn from a prior study at our institution. Femoral coronal and sagittal angles (FCA, FSA), tibial coronal and sagittal angles (TCA, TSA), and implant overhang were radiologically measured to identify outliers.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 269 - 269
1 Jul 2008
LECUIRE F JALOUL K RUBINI J BASSO M BENAREAU I
Full Access

Purpose of the study: The Alpina unicompartimen-tal knee prosthesis (Biomet) is an anatomic prosthesis inserted with a femoral cut, a tibial base plate made of titanium and a flat modular polyethylene insert. Cemented and non-cemented versions are available with hydroxyapatite ceramic (HAC) coating. Material and methods: We retrospectively reviewed the radiological outcome at more than five years (fie to eight years follow-up) in a consecutive series of patients who had an Alpina HAC prosthesis with tibial fixation completed with a titanium screw. Clinical and radiological findings were recorded. Radiologically: pre- and postoperative angles, implant position, reliability of the instrument set. At last follow-up, we studied the presence of lucent lines, polyethylene wear easily measured on the flat insert, and bone remodeling around the tibial fixation screw. Results: At last follow-up (5 to 8 years), three patients were lost to follow-up and three had died. Radiological outcome was thus assessed for 44 implants (41 medial and 3 lateral). One patient required an early total knee prosthesis (diagnostic error). Three patients underwent revision at 5–7 years (for rupture of the polyethylene insert in two very active patients, and for significant polyethylene wear in the third). Two had a revision procedure for a partial knee prosthesis and the third for a total knee prosthesis. For the 40 other patients, the following observations were made: partial lucent line along the tibial polyethylene plate with no functional impact (n=1), polyethylene wear visible but measuring less than 1 mm (n=12), remodeling around the tibial fixation screw probably corresponding to a granuloma but not threatening the implant (n=10). Discussion: The clinical results of partial knee prostheses are well known. Mid-term radiographic results of non-cemented unicompartmental prostheses with a flat tibial plateau producing a minimal contact surface has shown: good reliability of the instrument set, excellent bony integration of the HAC-coated implants, but measurable polyethylene wear on more than one quarter of the prostheses, with two ruptures of the polyethylene insert at 5 and 6 years. Conclusion: A study currently under way will examine finished pieces on a simulator to study wear and failure as a function of several parameters: polyethylene thickness, lateral restraint with a metal rim, presence of a basal stem fixing the polyethylene on the metal base, importance of the femur-polyethylene surface contact


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 10 - 10
7 Nov 2023
Arnolds D Marie-Hardy L Dunn R
Full Access

Adolescent idiopathic scoliosis is a three-dimensional deformity of the spine, affecting 1–3% of the population.

Most cases are treated conservatively. Curves exceeding 45° in the thoracic spine and 40° in the lumbar spine may require correction and fusion surgery, to limit the progression of the curve and prevent restrictive pulmonary insufficiency (curves above 70°). When fusion is required, it may be performed either by posterior or anterior approaches. Posterior is useful for thoracic (Lenke I) curves, notably to correct the thoracic hypokyphosis frequently observed in AIS. Anterior approaches by thoraco-lombotomies allow an effective correction of thoraco-lumbar and lumbar curves (Lenke V and VI), with fewer levels fused than with posterior approaches. However, the approach requires diaphragm splitting and one may be concerned about the long-term pulmonary consequences. The literature provides conflicting insight regarding the consequences of the approach in anterior scoliosis correction, the interpretation of the results being difficult knowing that the correction of the scoliosis itself may improve pulmonary function.

This is a retrospective observational study done at a Tertiary Institution. The HRQOL scores have been collected as a prospective cohort. Clinical and radiographic data was collected from patients charts and analysed by two senior surgeons

A cohort of 64 patients were operated in the given time period. 50 patients met the inclusion criteria. No major complications were reported. The Union rate was 100% and no post operative complications were noted. Pre and post SRS scores improved in all patients.

The Anterior approach for Lenke V AIS gives great surgical exposure and allows for excellent correction of Cobb angle with minimal risk to the patient.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 516 - 516
1 Oct 2010
Grabmeier G Berger C Engel A Newrkla S Seidl S
Full Access

Background: Patients with femoral head osteonecrosis usually tend to be younger and more active when compared with osteoarthritis patients. Second generation metal-on-metal THA was reintroduced to reduce poly-ethylene-induced wear debris, and therefore increase longevity of implants. The aim of this retrospective study was to compare full blood cobalt-chrome levels, patient activity, clinical/radiological outcome and implant survival in patients with osteonecrosis and osteoarthritis after a minimum follow up of 12 years. Methods: Full blood cobalt-chrome levels of a consecutive series of 125 patients, consisting of 40 patients (38 male, 2 female, average age 35 years, range 28 to 46 years) with osteonecrosis (ON group) and 85 patients (60 male, 25 female, average age 58 years, range 52 to 68 years) with osteoarthritis (OA group) as primary diagnosis were retrospectively compared. Patient activity level was assessed using UCLA Score and clinical outcome was evaluated using HHS. Radiological outcome and implant survival (Kaplan Meyer analysis) was determined in both groups. Results: Patients with osteonecrosis of the femoral head showed significant higher UCLA scores when compared to OA group (4 versus 7) (p < 0.05). Despite this higher patient activity no significant difference was found between cobalt-chrome full blood levels (2.1/1.6 μg/l, ON group, 1.9/1.8 μg/l OA group, respectively) (p > 0.05). No positive correlation between patient activity, acetabular cup abduction angle and cobalt-chrome levels was found (r. 2. < 0.01). Clinical and radiological outcome were equal in both groups. Harris hip score was 91 points in the OA and 92 in the ON group (p > 0.05). Average cup inclination angle was 47° (range 32° to 55°) and 44° (range 30° to 56°) respectively (p > 0.05). Implant survival at 12 years follow up was 96% in the OA and 97% in the ON group. Conclusion: After a minimum follow up of 12 years, we could not find increased metal levels in osteonecrosis patients when compared to the osteoartrithis group. Regarding our clinical and radiological outcome we cannot confirm previously published reports showing suboptimal results of THA in patients with osteonecrosis. Implant survival data did not differ among both group. Metal on metal THA seems to be an effective and safe treatment option for these patients


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 66 - 73
1 May 2024
Chaudhry F Daud A Greenberg A Braunstein D Safir OA Gross AE Kuzyk PR

Aims

Pelvic discontinuity is a challenging acetabular defect without a consensus on surgical management. Cup-cage reconstruction is an increasingly used treatment strategy. The present study evaluated implant survival, clinical and radiological outcomes, and complications associated with the cup-cage construct.

Methods

We included 53 cup-cage construct (51 patients) implants used for hip revision procedures for pelvic discontinuity between January 2003 and January 2022 in this retrospective review. Mean age at surgery was 71.8 years (50.0 to 92.0; SD 10.3), 43/53 (81.1%) were female, and mean follow-up was 6.4 years (0.02 to 20.0; SD 4.6). Patients were implanted with a Trabecular Metal Revision Shell with either a ZCA cage (n = 12) or a TMARS cage (n = 40, all Zimmer Biomet). Pelvic discontinuity was diagnosed on preoperative radiographs and/or intraoperatively. Kaplan-Meier survival analysis was performed, with failure defined as revision of the cup-cage reconstruction.


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims

This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA).

Methods

From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery.


Bone & Joint Open
Vol. 5, Issue 5 | Pages 374 - 384
1 May 2024
Bensa A Sangiorgio A Deabate L Illuminati A Pompa B Filardo G

Aims

Robotic-assisted unicompartmental knee arthroplasty (R-UKA) has been proposed as an approach to improve the results of the conventional manual UKA (C-UKA). The aim of this meta-analysis was to analyze the studies comparing R-UKA and C-UKA in terms of clinical outcomes, radiological results, operating time, complications, and revisions.

Methods

The literature search was conducted on three databases (PubMed, Cochrane, and Web of Science) on 20 February 2024 according to the guidelines for Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA). Inclusion criteria were comparative studies, written in the English language, with no time limitations, on the comparison of R-UKA and C-UKA. The quality of each article was assessed using the Downs and Black Checklist for Measuring Quality.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 668 - 678
1 Jun 2023
Friedman RJ Boettcher ML Grey S Flurin P Wright TW Zuckerman JD Eichinger JK Roche C

Aims

The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system.

Methods

We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217).


Bone & Joint Open
Vol. 5, Issue 5 | Pages 411 - 418
20 May 2024
Schneider P Bajammal S Leighton R Witges K Rondeau K Duffy P

Aims

Isolated fractures of the ulnar diaphysis are uncommon, occurring at a rate of 0.02 to 0.04 per 1,000 cases. Despite their infrequency, these fractures commonly give rise to complications, such as nonunion, limited forearm pronation and supination, restricted elbow range of motion, radioulnar synostosis, and prolonged pain. Treatment options for this injury remain a topic of debate, with limited research available and no consensus on the optimal approach. Therefore, this trial aims to compare clinical, radiological, and functional outcomes of two treatment methods: open reduction and internal fixation (ORIF) versus nonoperative treatment in patients with isolated ulnar diaphyseal fractures.

Methods

This will be a multicentre, open-label, parallel randomized clinical trial (under National Clinical Trial number NCT01123447), accompanied by a parallel prospective cohort group for patients who meet the inclusion criteria, but decline randomization. Eligible patients will be randomized to one of the two treatment groups: 1) nonoperative treatment with closed reduction and below-elbow casting; or 2) surgical treatment with ORIF utilizing a limited contact dynamic compression plate and screw construct. The primary outcome measured will be the Disabilities of the Arm, Shoulder and Hand questionnaire score at 12 months post-injury. Additionally, functional outcomes will be assessed using the 36-Item Short Form Health Survey and pain visual analogue scale, allowing for a comparison of outcomes between groups. Secondary outcome measures will encompass clinical outcomes such as range of motion and grip strength, radiological parameters including time to union, as well as economic outcomes assessed from enrolment to 12 months post-injury.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 50 - 50
1 Jan 2016
Moo IH Pagkaliwagan EH Poon KB
Full Access

Interest in minimal-incision total knee arthroplasty (TKA) has increased in recent years. The advantages of minimally invasive techniques (MIS) used for TKA are faster functional recovery, shorter hospital stay and better early knee range of motion. It is known that the long-term outcome after TKA is related to component position and ligament balance. The smaller incision in MIS might be associated with increased risk of malalignment of components due to limited visualisation. Malalignment of implants in TKA has been associated with implant failure and poor long-term functional results. There is a lack of evidence in the literature that MIS can achieve the same results as the standard TKR approach in terms of component alignment precision. Seventy patients scheduled for a primary TKA were prospectively evaluated postoperatively with coronal and sagittal radiographic long limb films. Mini-midvastus approach was used for all TKA. There were no complications and the radiographic evaluation found no implant or limb malalignment, or signs of early loosening. We did not observe wound healing problems, fractures or implant notching. The mini-midvastus approach can reproduces the same accuracy in component positioning as the standard medial parapatellar approach. A precise operation technique and adequate visualisation of anatomical landmarks during implantation are the key points of success in mini-midvastus approach.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 257 - 264
1 Feb 2022
Tahir M Mehta D Sandhu C Jones M Gardner A Mehta JS

Aims

The aim of this study was to compare the clinical and radiological outcomes of patients with early-onset scoliosis (EOS), who had undergone spinal fusion after distraction-based spinal growth modulation using either traditional growing rods (TGRs) or magnetically controlled growing rods (MCGRs).

Methods

We undertook a retrospective review of skeletally mature patients who had undergone fusion for an EOS, which had been previously treated using either TGRs or MCGRs. Measured outcomes included sequential coronal T1 to S1 height and major curve (Cobb) angle on plain radiographs and any complications requiring unplanned surgery before final fusion.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 88 - 88
1 Dec 2015
Weerwag L Schreurs B Rijnen W
Full Access

Prosthetic joint infection (PJI) is a severe complication of prosthetic joint implantation, with an estimated incidence of 2.18%. Most frequently used treatment strategy for PJI is a two-stage revision procedure. However there are specific patients with a new or persisting infection after primary or revision surgery where further surgical treatment is not attractive. This may be because of medical or local surgical conditions, or patient's refusal to undergo (further) surgical therapy. For these patients suppressive antibiotic therapy (SAT) may be an alternative treatment.

The aim of this study is to describe the clinical and radiological outcome of patients with a PJI of a hip arthroplasty, treated with SAT.

Twenty-four patients with a hip arthroplasty treated with suppressive antibiotic therapy for PJI between January 1, 2008 and December 31, 2013 were included. All patients had a proven prosthetic joint infection, either by ≥2 intraoperative cultures or joint aspiration. SAT was defined as treatment with antibiotic therapy for more than three months. Most used antibiotics were doxycycline in 15 patients and cotrimoxazole in six patients.

Patients were supposed to have a successful outcome when their prosthesis remained in situ and they had no relapse or new infection.

Suppressive antibiotic therapy was considered successful in 15 (62.5%) patients with a mean follow-up of 20.6 months. Two patients (8.3%) had to stop the antibiotic therapy due to adverse effects.

The mean duration of the SAT was 20.4 months (range 0.92–92.65 months).

Mean modified Oxford hip score of the successfully treated patients at the latest follow up was 35 (range 16–49) and mean Harris hip score 71 (range 40–93). The mean visual analogue scale (VAS) was 16 (range 0–70) in rest, 32 (range 0–85) during exercise and 65 (range 10–100) for satisfaction.

Of the 9 patients with an unsuccessful outcome, there was a radiological loosening of the cup in 4 patients. In the group of 15 patients that were considered successful, 2 patients had a radiological loosening of the cup and one patient loosening of the stem.

Suppressive antibiotic therapy can be an attractive alternative treatment in selected patients with a prosthetic joint infection of a hip arthroplasty who cannot or will not undergo (further) surgical therapy.

Further research with a larger number of patients is required. Also the optimal dosage and duration of suppressive antibiotic therapy and possible resistance to the antibiotic therapy is unknown.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1189 - 1195
1 Nov 2023
Kim JS Kim SH Kim SC Park JH Kim HG Lee SM Yoo JC

Aims

The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes.

Methods

This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group).


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 593 - 593
1 Oct 2010
Dornacher D Nelitz M Reichel H
Full Access

Reduction therapy in developmental dysplasia of the hip (DDH) is initialized in the newborn period. Harness treatment is continued until normal ultrasound-values are reached. Above the age of one year the assessment of DDH relies mainly on interpretation of plain radiographs of the pelvis. In order to rule out residual dysplasia after ultrasound controlled treatment radiological control is advised to the time children start walking. The purpose of this study is to evaluate the early radiological outcome after ultrasound controlled treatment of DDH and to examine whether there is a correlation between the initial severitiy of DDH, measured by ultrasound, and the severity of residual DDH on the radiograph at the time of the first follow-up.

A. p. pelvic radiographs of 90 children (72 girls, 18 boys, 180 hips) with DDH (29 unilateral, 61 bilateral) were reviewed retrospectively. To the beginning of the ultrasound surveilled therapy (mean age 7,2 weeks) the morphologic findings were staged according to the Graf classification. Ultrasound surveilled abduction treatment was continued until normal ultrasound findings were reached. To the time children started walking (mean age 14,8 months) an a. p. radiograph of the pelvis was performed. The acetabular index (AI) was measured and classified according to the normal values of the hip joint described by Tönnis. The initial ultrasound findings expressed by the Graf classification were compared with the AI in the radiographic follow-up and Tönnis’ normal values.

To simplify matters the 180 Graf-classified hips were distributed into 4 categories: Graf Ia/b=category 1, Graf IIa-D=category 2, Graf IIIa/b=category 3, Graf IV=category 4. The initially normal contralateral hips in ultrasound (n=29, category 1) presented in 37,9% a normal AI, in 41,4% with a mild dysplasia (between 1SD and 2SD) and in 20,7% with a severe dysplasia (beyond 2SD). The Graf type IIa-D hips (n=81, category 2) presented in 37% a normal AI, 32,1% showed a mild dysplasia and 30,9% a severe dysplasia. The Graf type III a/b hips (n=60, category 3) showed 35%, 30% and 35%, Graf type IV hips (n=10, category 4) 60%, 30% and 10%, respectively.

The mean AI in all four categories differed only marginally.

In our setting of patients different conclusions can be drawn:

Even after successful ultrasound guided therapy with a sonographically normal hip at the time bracing is finished there is a risk for residual dysplasia. Therefore radiological follow-up of every once treated hip is necessary.

To reduce the number of radiographs the time for the first radiographic follow up may be delayed to the age of two. We only see a minimal risk to miss a dislocated hip in time. In very rare cases the indication for an acetabuloplasty is generally seen before the age of two, in our patient population we saw no immediate indication for surgery.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 14 - 14
1 Mar 2012
Zhao G Yamamoto T Ikemura S Motomura G Nakashima Y Mawatari T Iwamoto Y
Full Access

Introduction

Transtrochanteric curved varus osteotomy is one of the effective joint-preserving operations for osteonecrosis (ON) of the femoral head. We correlated various factors with the radiological outcome of this procedure.

Methods

We reviewed 74 hips in 63 patients who had a minimum follow-up of 5 years after transtrochanteric curved varus osteotomy for the treatment of ON. There were 28 men and 35 women who had a mean age of 33 years (range, 15 to 68 years) at the time of surgery. Clinical assessment was made based on the Harris hip score (HHS). Radiographically, we investigated various factors; affected lesion, stage and type (localization of the necrotic lesion) of ON, varus degree, post-operative intact ratio, progression of collapse, and joint-space narrowing. On the basis of postoperative radiographs, the hips were divided into 2 groups (Group I: either the progression of collapse or joint-space narrowing, Group II: neither progression of collapse or joint-space narrowing). The related factors with radiological outcome were analyzed by using multivariate analysis (Stepwise discriminant analysis).


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 146 - 146
1 Apr 2005
McAllen C Eyres K
Full Access

Study Aims The purpose of this study is to determine whether the cement mantle produced when a suction cement technique is used leads improved radiological results in the medium term.

Methods 74 patients who had a cemented total knee replacement were prospectively studied. In 51 patients the cement was applied in a standard fashion. In 23 patients an intraosseous cannula was used to apply suction within the bone to improve cement penetration. The cannula was inserted into the medial femoral condyle and the medial tibial plateau prior to the bone preparation to vent both bones. Suction is applied to help dry the cancellous surface and draw the cement into the bone.

The radiological appearance of the tibial components were prospectively examined to for the appearance of bone lysis.

Conclusion This study shows that this technique produces superior radiological appearances in the medium term, which may lead to longer implant survival.

A previously published study has shown that if total knee replacement is performed without a tourniquet but using the suction cement technique an excellent cement mantle can reliably be produced.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 53 - 53
1 Feb 2017
Kawamoto T Iida S Suzuki C
Full Access

Background

Variability in component alignment continues to be a major in total knee arthroplasty(TKA). In the long term, coronal plane malalignment has been associated with an increased risk of loosening, insatability, and wear. Recently portable navigation system(PNS) in TKA have been introduced. The goal of PNS are to improve the accuracy of post operative alignment and eliminate outlier cases. The aim of this study is to evaluate clinical results and quantify the coronal plane alignment between a group of patients who underwent TKA using PNS versus CT-free large-console navigation system.

Patients and Method

An unselected consecutive series of ninety-four patients undergoing primary TKA using the cruciate retaining cemented total knee system between April 2012 and August 2015 were studied. Patients were included only if they were deemed to be candidates for a Cruciate retaining TKA. Patients were excluded if they had a flexion contracture greater than 40°, or severe valgus or varus deformity. Forty eight knees was operated a TKA with CT-free large-console navigation system(The OrthoPilot system; Aesculap, Tuttlingen, Germany). Subsequently forty six knees was received a TKA using portable navigation system (KneeAlign2TM). Postoperatively standing AP hip-to-ankle radiographs were obtained, from which the lower extremity mechanical axis, component angle were measured. The alignment goals were a neutral mechanical axis defined as a hip-to-ankle angle of 0°with the femoral and tibial components aligned perpendicular to the mechanical axis. The total operating time were quantified utilising an operating room database. The total operating time between TKAs performed with CT-free navigation system and those performed with portable navigation system was compared in each group. All patients postoperatively was evaluated of clinical results the Japan Orthopedics Association(JOA) Knee scores.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 81 - 81
1 Jan 2004
Moran M Soon YL Walmsley P Brenkel IJ
Full Access

Introduction: There is little published on the outcome of orthopaedic surgery performed by surgeons in training. The individual results of orthopaedic units and consultants are coming under increasing scrutiny. There may be concerns that trainee performed THR will negatively impact on these figures. This study compares the outcome of THR’s performed by consultants and supervised trainees.

Methods: Data was prospectively collected on 139 THR’s carried out by supervised specialist registrars (years 1 to 4) and 397 THR’s carried out by consultants. The Harris Hip Score (HHS) was used as the primary outcome measure and scores were taken at 7days pre-operatively, 6 and 18 months post-operatively. In addition data on co-morbidity, blood loss, transfusion requirements, re-operation, dislocation and death were recorded. Radiographs of 110 trainee and 110 consultant performed THR’s were compared at 6 months. Acetabular anteversion and abduction and femoral orientation were assessed on lateral and AP films. Cementation was judged using methods described by Hodgkinson and Barrack.

Results: Blood loss, transfusion requirement, dislocation, revision, deep infection and the HHS at 6 and 18 months showed no statistically significant difference between trainee and consultant (all p< 0.05). Component orientation and cementation quality again showed no significant difference (p< 0.05).

Discussion: This paper reveals no difference in the short term results of THR performed by consultants and supervised trainees. Our results show that quality can be maintained whilst training juniors to operate.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 360 - 365
1 Feb 2021
Mahendraraj KA Shields MV Grubhofer F Golenbock SW Jawa A

Aims

Existing literature indicates that inferiorly inclined glenoid baseplates following reverse total shoulder arthroplasty (RSA) produce better outcomes compared to superiorly inclined baseplates. We aim to compare clinical outcomes for RSAs with superiorly and neutrally/inferiorly inclined lateralized glenospheres.

Methods

We retrospectively reviewed 154 consecutive patients undergoing RSA between July 2015 and July 2017 by one single-fellowship trained surgeon (AJ). Two raters (KAM and MVS) independently measured glenoid inclination in preoperative and minimum two year follow-up radiographs (anteroposterior/Grashey) using the RSA angle. Inclination was then compared to patient-reported outcomes, range of motion (ROM), and independently assessed degree of scapular notching and staging of heterotopic ossification at two year follow-up.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 390 - 390
1 Jul 2011
Ball S Windley J Harnett P Nathwani D
Full Access

Computer navigation has the potential to revolutionise orthopaedic surgery. It is widely accepted that component malalignment and malrotation leads to early failure in knee arthroplasty. We aimed to assess the use and reliability of computer navigation in both total (TKR) and unicompartmental (UKR) knee replacement surgery.

We analysed 40 consecutive UKRs and 40 consecutive TKRs. All procedures were carried out with the Brain-LAB navigation system and all were carried out by one consultant orthopaedic surgeon. Preoperative aim was neutral tibial cuts with 3 degrees posterior slope. Coronal and sagittal alignment of tibial components were measured on postoperative radiographs. Patients were also scored clinically with regards to function and pain.

In the TKR group, mean tibial coronal alignment was 0° (range 1 to −2.) Mean sagittal alignment was 2° posterior slope (range 0 to 4.) In the UKR group, mean tibial coronal alignment was 0.55° (range 0 to −3.) Mean sagittal alignment was 2.1° posterior slope (range 0 to 4°.) Clinical outcome scores were very satisfactory for the majority of patients, with far superior functional scores in the UKR group.

Our results demonstrate very accurate placement of the prosthesis in both the TKR and UKR group with computer navigation. There is a very narrow range with no outliers, (all within +/−3 degrees of desired alignment.) Functional outcome scores are good. We advocate the use of computer navigation in unicompartmental as well as total knee replacment surgery, in order to minimise early failures.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 123 - 123
1 May 2011
Salvo D Holzer N Lübbeke A Hoffmeyer P Assal M
Full Access

Introduction: An ankle fracture represents the most frequent osseous injury in both the elderly and non-elderly population. To date, only a limited number of retrospective studies have addressed medium-term outcome following ankle Open Reduction and Internal Fixation (ORIF). The purpose of this study was to assess residual pain and functional outcome 10 to 20 years after operative treatment of ankle fractures and to evaluate the incidence of symptomatic and radiographic ankle osteoarthritis (OA).

Methods: We designed a retrospective study including all consecutive patients who underwent ankle ORIF between January 1988 and December 1997 in a University Hospital setting. Pilon and talus fracture as well as pediatric patients were excluded. Patients were seen by two senior residents 10–20 years after their index surgery. Residual pain was measured using the Visual Analog pain Scale. Function and general health status were assessed using the Olerud and Molander Ankle Score, the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score and the 12-item short-form health survey (SF-12). Ankle OA on standard radiographs was scored according to the revised Kellgren and Lawrence (K& L) scale.

Results: 374 patients (56% men) underwent ankle surgery during the defined period. 10% of the patients had a Weber A fracture, 57% a Weber B and 33% a Weber C fracture. Mean age at the time of operation was 42.9 years (+/− 17.1; range 16–86 years). 10–20 years after surgery, 47 patients had died, 126 had left the country and were lost to follow-up, 99 did not respond or refused to participate, and 102 patients were seen at the follow-up visit. These patients did not differ in terms of age, gender distribution, BMI and type of fracture from those who were not seen. The mean duration of follow up was 17.3 years (+/− 3.3). Advanced radiographic OA (K& L grade 3 and 4) was present in 34.3 % of the patients. Symptomatic OA was reported by 34.3 % of the patients (AOFAS pain score < 40). Both clinically symptomatic and radiographic ankle OA was found in 18 patients (17.6%). Function was good in 85% of the cases (total AOFAS hindfoot score between 80 and 100 points; mean total AOFAS hindfoot score 89.9, +/−14.6). The mean Olerud and Molander ankle score was 86.5 (+/−18.7). The general health status (SF-12) was similar to representative values of the general population with a similar mean age.

Conclusion: 10–20 years after operative treatment of an ankle fracture, the incidence of advanced radiographic post-traumatic ankle OA was 35%, symptomatic OA was present in one third of the patients and about one fifth had both. The majority of the patients reported good function.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 28 - 28
1 Jan 2011
Khurana A Guha A Mohanty K Ahuja S
Full Access

Sacroiliac joint (SIJ) is a diarthrodial joint and can often be a source of chronic low back pain complex. We present a percutaneous technique for SIJ fusion and the functional and radiological outcome following arthrodesis with HMA (Hollow modular anchorage; Aesculap Ltd, Tuttlingen) screws.

Fifteen consecutive patients operated for SIJ fusion between Sep 2004 and Aug 2007 were included in the study. The diagnosis was confirmed with MRI and diagnostic injections. Pre-operative and post-operative functional evaluation was performed using SF-36 questionnaire and Majeed’s scoring system. Postoperative radiological evaluation was performed using plain radiographs. The HMA screws packed with bone substitute were implanted percutaneous under fluoroscopic guidance.

The study group included 11 females and 4 males with a mean age of 48.7 years. Mean follow-up was 14 months. Mean SF-36 scores improved from 37 to 80 for physical function and from 53 to 86 for general health. The differences were statistically significant (Wilcoxon signed rank test; p < 0.05). Majeed’s score improved from mean 37 preoperative to mean 79 postoperative. The difference was statistically significant (student t test, p< 0.05). 13 had good to excellent results. The remaining 2 patients had improvement in SF-36 from mean 29 to 48. Persisting pain was potentially due to coexisting lumbar pathology. Intra-operative blood was minimal and there were no post-operative or radiological complications.

Percutaneous HMA screws are a satisfactory way to achieve sacroiliac stabilisation.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 535 - 535
1 Oct 2010
Daniilidis K Fischer F Skuginna A Skwara A Tibesku C
Full Access

Aim: Cementation of tibial implants in total knee arthroplasty is a gold-standard considering the high loosening rates of cementless implants. In contrast, only sparse data exist regarding unicondylar arthroplasty due to limited use. In this study, we compare cemented with cementless unicondylar knee arthroplasty and aim to define both clinical and radiological differences in treatment outcome.

Materials and Methods: In a retrospective study, 106 patients who had undergone a medial unicondylar replacement were examined after a mean postoperative period of 8 years. Of these, 42 patients (median age 81±7 years) had received a cemented and 64 (median age 73±7 years) a cementless knee arthroplasty by the same surgeon while 7 patients were deceased or could not be reached. Well-established clinical (VAS, HSS, KSS, UCLA, WOMAC) and quality of life (SF-36) scores were used to evaluate treatment outcome. X-rays were performed to evaluate periprosthetic loosening zones, according to Ewald’s criteria.

Results: The cementless patient group presented significantly better clinical scores (HSS, KSS, UCLA, WOMAC), except in the Visual Analogue Scale (VAS) for pain assessment. The quality of life was significantly better in the cementless group except in the subgroups concerning physical function, vitality and social role, which resembled normal population. Moreover, radiographic analysis using antero-posterior X-rays revealed significantly more and larger periprosthetic loosening areas in tibial zone 2 in the cementless group.

Conclusion: The inferior clinical results characterising the cemented group could be attributed to the higher mean age. Regarding the radiological loosening zones, we did not detect any differences in the techniques of fixation, although physical activity and mechanical stresses were higher in the cementless group.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_19 | Pages 23 - 23
1 Apr 2013
Iqbal S Iqbal HJ Hyder N
Full Access

Introduction

The distal radius is the most frequently fractured bone in the forearm with an annual fracture incidence in the UK of about 9–37 in 10,000. Restoration of normal anatomy is an important factor that dictates the final functional outcome. A number of operative options are available, including Kirschner wiring, bridging or non-bridging external fixation and open reduction and internal fixation by means of dorsal, radial or volar plates. We designed this study to analyse the clinical and radiological outcome of distal radial fracture fixation using volar plating.

Materials/Methods

Thirty-seven patients with distal radius fractures undergoing open reduction and internal fixation using volar plates were included. Tilt of the fractured distal radial fragment was recorded from the initial radiograph and classification of fractures was done using the Orthopaedic Trauma Association system. The QuickDASH questionnaire was used for evaluation of symptomatic and functional outcome six months to one year after surgery. The radiological outcome was assessed using measurements of radial inclination, ulnar variance and volar tilt. Of the thirty-seven patients, 13 were male and 24 were female. The mean age was 55.6 years (range 18–87 years). According to the AO classification, there were 8 cases each of C2 and C3 fractures, 6 cases of C1 fractures and 3 cases each of class A2, A3, B1 and B3 fractures. There were 2 patients with class B2 fracture.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 495 - 495
1 Sep 2009
Khurana A Guha A Howes J Jones A Davies P Mohanty K Ahuja A
Full Access

Introduction: Sacroiliac joint (SIJ) is a diarthrodial joint and can often be a source of chronic low back pain complex. We present a percutaneous technique for SIJ fusion and the functional and radiological outcome following the arthrodesis.

Aims and Objectives: To evaluate the functional and radiological outcome following percutaneous technique for SIJ fusion with HMA (Hollow modular anchor-age) screws.

Materials and Methods: 15 consecutive patients operated for SIJ fusion between Sep 2004 and Aug 2007 were included in the study. The diagnosis was confirmed with MRI and diagnostic injections. Pre-operative and post-operative functional evaluation was performed using SF-36 questionnaire and Majeed’s scoring system. Postoperative radiological evaluation was performed using plain radiographs. The Hollow modular anchorage (HMA) screws (Aesculap Ltd, Tuttlingen) packed with bone substitute were implanted percutaneous under fluoroscopic guidance

Results: The study group included 11 females and 4 males with a mean age of 48.7 years. Mean follow-up was 14 months. Mean SF-36 scores improved from 37 to 80 for physical function and from 53 to 86 for general health. The differences were statistically significant (Wilcoxon signed rank test; p < 0.05). Majeed’s score improved from mean 37 preoperative to mean 79 postoperative. The difference was statistically significant (student t test, p< 0.05). 13 had good to excellent results. The remaining 2 patients had improvement in SF-36 from mean 29 to 48. Persisting pain was potentially due to coexisting lumbar pathology. Intra-operative blood was minimal and there were no post operative or radiological complications in any patient.

Conclusion: Percutaneous HMA screws are a satisfactory way to achieve sacro-iliac stabilisation.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 29 - 30
1 Mar 2009
Biedermann R Donnan L Gabriel A Wachter R Krismer M Behensky H
Full Access

Periacetabular osteotomy (PAO) is a well established method to treat hip dysplasia in the adult. There are, however, a number of complications associated with this procedure as well as a time related deterioration in the grade of osteoarthritis that can influence the long term result. It is essential that patients are fully informed as to the effectiveness of PAO, the likelihood of complications and their influence on the subjective outcome prior to giving consent for surgery. Generic outcome measures offer the opportunity to determine treatment efficacy and the influence on the outcome by complications.

60 PAOs on 50 patients were investigated retrospectively after a mean follow up of 7.4 years. The patients’ self reported assessment of health and function was evaluated by the SF-36 and the WOMAC questionnaires at last follow-up. 40 healthy persons served as a control group.

The centre-edge angle improved from a mean of 8.7° to 31.5°. The weight bearing surface improved from a mean lateral opening of 8.7° to 4.2°. The degree of osteoarthritis improved in one case, remained unchanged in 20 and deteriorated in 17. There was a tendency of higher CE-angles towards a higher rate of deterioration, indicating that overcorrection may increase osteo-arthritic degeneration. 13 of the 60 interventions had no complications. Minor complications occurred in 25 (41%) interventions and in 22 (37%) at least one major complication occurred. SF-36 summary measure was 76.4 for PAO patients and 90.3 for the control group. Mean WOMAC score was 25.1. The severity of ectopic bone formation, incidence of postoperative peroneal nerve dysfunction and delayed wound closure did not influence the subjective result. Patients with major complications had a similar subjective outcome as patients with minor or no complications, but persistent dysesthesia due to lateral femoral cutaneous nerve dysfunction led to a worse subjective function as assessed with the WOMAC score.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 31 - 31
1 Sep 2014
Mughal A Kruger N
Full Access

Purpose of Study

Debate exists in the literature about the surgical management of sub-axial cervical burst fractures regarding the approach and types of fixation of these injuries. Our Acute Spinal Injury (ASCI) unit prefers anterior only cervical corpectomy and plate fixation in the management of these injuries. The objective of this study was to radiologically assess the long term outcomes (minimum 2 yrs) of our series.

Patients and Methods

Patients were identified using the Acute Spinal Injury Unit (ASCI) database that had had anterior only corpectomy and plate fixation for trauma as a standardised procedure between 2006 and 2009. Initial post-op radiological review included the sagittal alignment, hardware characteristics and surgical technique. Radiological review after a minimum of 24 months involved the union, sagittal alignment, hardware characteristics, graft incorporation and adjacent level degeneration at the site of injury.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 25 - 25
1 Jul 2012
Robb C Dixon J Parker L Baloch K Pynsent P
Full Access

Aims

The purpose of our study was three fold; firstly to assess the survival of closing wedge high tibial osteotomies (CWHTO), secondly to assess any clinical factors or radiological alignment which may affect survival and thirdly to assess the change in tibial inclination and patella height.

Methods

Details of 51 patients undergoing CWHTO for varus gonarthrosis between 1999 and 2007 were assessed for age, BMI, gender, range of movement, meniscal integrity and grade of arthritis. Radiological evaluation included pre and post-operative femoro-tibial axis, tibial slope and patella height. Outcome was also evaluated by Oxford knee score and UCLA activity score. Failure was considered as conversion to arthroplasty.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 142 - 142
1 Apr 2012
Dhir J Carpenter C Pande R Pyrovolou N Ahuja S
Full Access

We do know that the use of stand-alone cage with no plate is prone to subsidence and segmental kyphosis. Cage and plate construct are prone to adjacent level ossification. Zero P (Synthes, UK) cage combines the functionality of spacer and anterior plate.

Radiological evaluation of subsidence of cervical spine after anterior cervical interbody fusion using Zero P cage system.

Method: Retrospective review of radiographic records of patients undergoing surgery between June 2008- Oct 2009. We evaluated lateral cervical standing radiographs before, after, 6 weeks, 3, 6 months of surgery. We measured subsidence (using Total Intervertebral Height (TIH). All measurements were done using Web 1000 (Impax Agfa). Two level was treated as single segment. Subsidence > 3mm was considered significant.

20 patients (11 male: 9 female) with median age of 51 yrs (40-65) underwent one (n=10) or two level (n= 10) cervical fusion. Immediately post-op there was increase in TIH in one and two level group by 1.74mm (1.61 and 4.25mm (1.48 respectively, which at 6 months reduced to 1.05mm (0.24 (p< 0.003) and 1.32mm (1.29 (p< 0.085) at 6 months respectively. Subsidence was seen in all cases and was rapid in first 3 months and then tailed off. It was significant (> 3mm) only in 2/20 (2%) patients at 6 months.

Early results indicate that spine alignment is maintained radiologically with no associated complications as screw loosening, cage extrusion etc.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 368 - 368
1 May 2009
Patterson P Bonner T McKenna D Womack J Briggs P Siddique M
Full Access

Introduction: The Scarf osteotomy for the treatment of hallux valgus is achieving popularity, but no comparative study has proven the efficacy of this procedure over other first metatarsal osteotomies.

We present a retrospective comparative review of the radiological outcomes of Chevron and Scarf with Akin osteotomy in the treatment of hallux valgus.

Materials and Methods: The radiological outcomes of 40 first metatarsal osteotomies, 20 Chevron and 20 Scarf with Akin are presented. The radiological parameters studied included hallux valgus angle, hallux inter-phallangeus, intermetatarsal angle, sesamoid station and foot width.

Results: The mean post-operative hallux valgus angles (HVA’s) were: Chevron mean HVA 17.90, standard deviation 7.360, standard error 1.65. Scarf with Akin osteotomy mean HVA 9.550, standard deviation 6.60, standard error 1.4. The difference in postoperative HVA between the two operations was statistically significant (p< 0.001).

The mean post-operative intermetatarsal angles (IMA) were: Chevron mean 8.050, standard deviation 2.560, standard error 0.57. Scarf with Akin mean 7.220, standard deviation 2.56, standard error 0.57. The difference in postoperative IMA between the two groups did not achieve statistical significance.

The mean change in IMA for each was: Chevron mean increment 4.90 Standard deviation 2.290, standard error 0.51. Scarf with Akin mean increment 6.680, standard deviation 4.130, and standard error 0.88. The difference in alteration of IMA between the two groups did not achieve statistical significance.

Discussion and Conclusion: We conclude that as there was no difference in the distribution of post-op IMA for Scarf and Chevron osteotomies that the added affect of an Akin osteotomy may contribute to the Scarf to produce the better correction in hallux valgus angle.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 4 - 4
1 Mar 2009
bhadra A Raman A Rai A Casey A Crawford R
Full Access

AIM: To compare the outcomes between two different surgical techniques for cervical myelopathy (skip laminectomy vs laminoplasty).

METHODS: Cervical skip laminectomy is a new technique described by Japanese surgeons in 2000. The advantage of this procedure over the other conventional techniques is it addresses multilevel problem in a least traumatic way without need for instrumentation.

We are comparing the above two techniques with 25 patients in each group operated by 3 surgeons. The first group had conventional laminoplasty and the second group underwent the skip laminectomy. The groups were comparable in age, sex, pathology and clinical presentation. Both these group had clinical outcome measurements using SF 12 questionnaires, pre and postoperative clinical assessment with standard tools performed by independent surgeon and a specialist spinal physiotherapist. We also routinely performed pre and postoperative MRI scans to assess the adequacy of decompression.

RESULTS & CONCLUSION: There was no significant difference in the outcome of these patients in terms of the operative technique, hospital stay, clinical and radiological outcome. However skip laminectomy is relatively a easier procedure to perform, while the laminoplasty does need instrumentation.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 181 - 181
1 May 2011
Vasireddy A Navadgi B Deo S Satish V Lowdon I
Full Access

Purpose of study: With the increasing demand for arthroplasty surgery, it is important to maintain a high quality of care. We describe a clinical governance framework for a simple, easy to implement method of assessing and monitoring radiological outcome following total knee arthroplasty.

Methods: We completed a two-year prospective study (January 2006 to December 2007 inclusive) of all total knee arthroplasty operations. This included 1,295 procedures, the majority of which were undertaken by two Consultant Surgeons and up to eight independent middle grade surgeons. The two Consultant Knee Surgeons assessed component position on standard post-operative weight-bearing antero-posterior and lateral knee radiographs on a weekly basis. They were blinded to both the patient and surgeon details, and used our own simple grading system, whose weighted Kappa variance showed ‘moderate’ interobserver (K = 0.41) and intraobserver reliability (K = 0.51). Our system comprised of only three ordinal scores, which were good (score of 1), acceptable (score of 2) and poor (score of 3).

Results: We provided individual surgeons with their results on a six-monthly basis. The average score for all the surgeons was good. The scores of the independent middle-grade surgeons were analysed by the Consultants, and feedback was provided in the form of formal advice and supervised surgery sessions. Repeat proportional analysis of their radiological scores showed significant improvements for all the individual surgeons (Pearson-Chi Square p value < 0.05).

Conclusions: Clinical governance is an important facet of excellence in medical practice. Our system allows continued prospective assessment of radiological outcome following total knee arthroplasty. By utilising such systems and ensuring an atmosphere of clinical excellence, we are able to employ more surgeons and undertake an increased workload, whilst maintaining high standards. This assessment tool can also be used to assess and appraise trainees during their progression.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 238 - 239
1 Sep 2005
Wardlaw D Choudhary S Muthukumar T Gibson S
Full Access

Study Design: A prospective randomised controlled trial with blind radiological assessment.

Objective: To assess the radiological outcome of instrumented posterolateral lumbar fusion in a prospective randomised study comparing the use of allograft (fresh frozen human femoral head) to autologous bone (from the posterior iliac crest) using a validated method.

Methods: Sixty-nine patients having instrumented postero-lateral fusion using the Steffee plate were randomised to one of two groups, to receive either allograft bone or autologous bone. The same surgeon using the same surgical technique performed or supervised all cases. The radiological results of the two groups were assessed as well as the quality of fusion.

Outcome measures: The radiographs were assessed for fusion or non-fusion by three independent observers using the same criteria, and a second time by one of the observers. The Kappa scores for the inter-observer and intra-observer agreement were calculated. Some of these patients had fusion status verified by the gold standard of surgical exploration and the sensitivity and specificity calculated. The clinical outcome is the subject of a different paper.

Results: Both the inter-observer and intra-observer kappa scores (k) were 100%. The sensitivity of the method was 87.9% and the specificity was 100%. Thirty-seven patients received allograft and 32 patients received autograft. There was no significant difference in the fusion rate, or the quality and quantity of the graft between the groups.

Conclusions: There is no difference in the fusion rates comparing the use of autograft and allograft for postero-lateral instrumented lumbar fusion.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 23 - 23
1 Mar 2005
Wardlaw D Choudhary S Muthukumar T Gibson S
Full Access

To assess the radiological outcome of instrumented posterolateral lumbar fusion in a prospective randomised study comparing the use of allograft (fresh frozen human femoral head) to autologous bone (from the posterior iliac crest), using a validated method.

One hundred and twenty four radiographs of patients who had undergone instrumented posterolateral spinal fusion were assessed for fusion or non-fusion by three independent observers using the same criteria, and a second time by one of the observers. The Kappa scores for the inter-observer and intra-observer agreement were calculated. Thirty-three of these patients had fusion status verified by the gold randomised to one of two groups, to receive either allograft bone or autologous bone. The same surgeon using the same surgical technique performed or supervised all cases. The radiological results of the two groups were assessed as well as the quality of fusion.

Both the inter-observer and intra-observer kappa scores (k) were 100%. The sensitivity of the method was 87.9% and the specificity was 100%. Thirty-seven patients received allograft and 32 patients received autograft. There was no significant difference in the fusion rate, or the quality and quantity of the graft between the groups.

There is no difference in the fusion rates comparing the use of autograft and allograft for posterolateral instrumented lumbar fusion.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 589 - 589
1 Oct 2010
Penna S Nalla R Sharma R
Full Access

Aim: We report radiological outcome following percutaneous minimally invasive corrention of Hallux Valgus using K-wire fixation.

Methods: We followed 15 patients (11 bilateral operations) who had above procedure for Hallux Valgus deformity correction. All patients had pre operative and post operative x-rays assessed for Hallux Valgus angle, 1st Intermetatarsal angle and Distal Metatarsal Articular angle. We also collected clinical data including deformity correction and complications.

Results: Mean age of the patients was 55.47(SD 14.27). Of the 15 procedures 11 had bilateral operations and 4 had only one side operated (total 14 right sided 12 left sided operations). Mean duration of follow up was 85.47 days (range 29 to 259). The pre operative mean Hallux Valgus angle was 37.05(SD 6.49, range 28 to 49) where as post operative it was 11.32(SD 9.07, range 0 to 33). The pre operative mean 1st Intermetatarsal angle was 16.46(SD 2.74, range 11 to 21) where as post operative it was 5.48(SD 3.62, range 1 to 16). The pre operative mean Distal metatarsal articular angle was 35.36(SD 8.38, range 18 to 51) where as post operative it was 8.29(SD 9.13, range 0 to 38). Clinically one great toe had infection post operatively requiring early removal of K-wires resulting in residual deformity. One had mild bilateral recurrence, two had mild unilateral recurrence. These patients did not require any further surgery.

Conclusion: Above results indicate that Percutaneous Minimally invasive Hallux Valgus correction using K-wire fixation showed good radiological correction in various angles measured to quantify Hallux Valgus deformity.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 147 - 147
1 Feb 2003
du Toit G Vlok G
Full Access

Most spinal pedicle fixation systems used in this country are imported and expensive. They mostly employ rigid or semi-rigid screws with a known and significant rate of implant failure. Though they are often designed for ease of insertion, many are difficult to remove.

This study investigated the radiological outcome of a dynamic spinal fixation system developed in South Africa with the aims of reducing costs, improving ease of insertion and removal, reducing the rate of implant failure, and at the same time meeting international standards.

A University Ethics Committee approved this study of 439 patients in whom the device was used in spinal surgery between 1997 and 2002. Of these patients, 121 had follow-up radiographs taken more than one year after surgery. These radiographs were independently reviewed and form the basis of this study.

In 93.4% of patients, the fusion was radiographically solid. The state of fusion was uncertain in 4.1%, and fusion had failed in 2.5%. Screw breakage occurred in 0.3%. There were no rod breakages. In 1% of patients there was evidence of screw-bone loosening. There were no signs of screw-rod breakage or loosening.

The device produces a satisfactory rate of fusion with a very low rate of implant failure. Awarded ISO 9001:2001 certification and the CE mark, it meets international standards at considerably reduced cost.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages - 38
1 Mar 2002
Assi C Faline A Canovas F Bonnel F
Full Access

Purpose: A pre- and postoperative radiographic analysis of 50 total knee arthroplasties (TKA) was performed to determine the femorotibial correction angle and the tibial and femoral mechanical angles obtained as a function of the initial bony deformity. The preoperative angle beyond which correction was not achieved was determined.

Material and methods: This prospective single-centre study included 50 TKA (25 men and 25 women), mean age 69.1 years (range 53–83). Degenerative disease involved the right knee in 21 cases and the left knee in 29. A Wallaby I TKA (semi-restrained with preservation of the posterior cruciate ligament) was implanted in all cases. Three angles were calculated on the AP loaded knee: AFT (femorotibial angle), AFM (femoral mechanical angle), ATM (tibial mechanical angle). For each angle, statistic analysis was performed on four groups of patients: group I: overall population, group II: patients with normal axis (178°< AFT< 182°; 88°< AFM< 92°; 88)< ATM< 92°), group III: patients with varus (AFT> 182°; AFM> 92°; ATM> 92°), and group IV: patients with valus (AFT< 178°; AFM< 88°; ATM< 88°). Non-parametric tests (Spearman rank test and MacNemar symmetry test) were performed on SAS software for statistical analysis with p< 0.05 considered as significant.

Results: Pre- and postoperative AFT showed: significant improvement of the mean (> 3.44° in group I, > 6.87° in group III, and > 6.12° in group IV). There was no significant difference in group II. Pre- and postoperative AFM showed: constant but non-significant improvement in groups I and III (> 3°) and constant and significant improvement in groups III and IV (> 2.5°). Pre- and postoperative ATM showed: significant improvement in groups I and III (> 3°), constant but non-significant improvement in group IV (n=4). There was no group II. An ATM > 94° was the threshold angle beyond which correction was not obtained.

Discussion: Taken together, the results of this study confirm the reliability of the Wallaby I instrumentation for achieving a correct postoperative mechanical axis. These results are comparable with data in the literature (with or without preservation of the posterior cruciate ligament). However, the correction of the bony deformity obtained depended uniquely on the initial deformity of the tibia. Extreme deformity of the tibia should be corrected with osteotomy or with a more restrained prosthesis.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 437 - 437
1 Aug 2008
Freeman B Hussain N Watkins R Webb J
Full Access

Introduction: Patient questionnaires permit a direct measure of the value of care as perceived by the recipient. The Scoliosis Research Society outcomes questionnaire (SRS-22) has been validated as a tool for self-assessment. We investigated the correlation between SRS-22 and a detailed radiological outcome two years following anterior correction of Thoraco-Lumbar Adolescent Idiopathic Scoliosis (TL-AIS).

Methods: The SRS-22 questionnaire was completed by 30 patients two years following anterior correction of TL-AIS. Pre-operative, post-operative and two year follow-up radiographs of all 30 patients were assessed. The following parameters were measured at each time point:

Primary Cobb angle,

Secondary Cobb angle,

Coronal C7-midsacral plumb line,

Apical Vertebra Translation (AVT) of primary curve,

AVT of the secondary curve,

Upper instrumented vertebra (UIV) translation,

UIV tilt angle,

Lower instrumented vertebra (LIV), 8) LIV tilt angle

Apical Vertebra Rotation (AVR) of the primary curve,

Sagittal C7-posterior corner of sacrum plumb line

T5-T12 angle,

T12-S1 angle,

shoulder height difference.

The percentage improvements for each were noted. Correlation was sought between Total SRS score, each of the five individual domains and various radiographic parameters listed above by quantifying Pearson’s Correlation Coefficient (r).

Results: Percentage improvement in primary Cobb angle (r = 0.052), secondary Cobb angle (r = 0.165) and AVT of the primary curve (r = −0.353) showed little or no correlation with the SRS-22 total score or any of its five domains. Significant inverse correlation was found between the UIV tilt angle at two years and the SRS-22 (r = −0.516). Lateral radiographs however showed little or no correlation between thoracic kyphosis (r = 0.043) and SRS-22.

Conclusion: The SRS-22 outcomes questionnaire does not correlate with most of the radiographic parameters commonly used by clinicians to assess patient outcome.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 451 - 451
1 Aug 2008
Hussain N Freeman BJC Watkins R Webb JK
Full Access

Introduction: Patient questionnaires permit a direct measure of the value of care as perceived by the recipient. The Scoliosis Research Society outcomes questionnaire (SRS-22) has been validated as a tool for self-assessment. We investigated the correlation between SRS-22 and a detailed radiological outcome two-years following anterior correction of ThoracoLumbar Adolescent Idiopathic Scoliosis (TL-AIS).

Methods: The SRS-22 questionnaire was completed by 30 patients two-years following anterior correction of TL-AIS. Pre-operative, post-operative and two-year follow-up radiographs of all 30 patients were assessed. The following parameters were measured at each time point: 1) Primary Cobb angle, 2) Secondary Cobb angle, 3) Coronal C7-midsacral plumb line, 4) Apical Vertebra Translation (AVT) of primary curve, 5) AVT of the secondary curve, 6) Upper instrumented vertebra (UIV) translation, 7) UIV tilt angle, 8) Lower instrumented vertebra (LIV), 8) LIV tilt angle 9) Apical Vertebra Rotation (AVR) of the primary curve, 10) Sagittal C7-posterior corner of sacrum plumb line 11) T5–T12 angle, 12) T12-S1 angle, 13) shoulder height difference. The percentage improvements for each were noted. Correlation was sought between Total SRS score, each of the five individual domains and various radiographic parameters listed above by quantifying Pearson’s Correlation Coefficient (r).

Results: Percentage improvement in primary Cobb angle (r = 0.052), secondary Cobb angle (r = 0.165) and AVT of the primary curve (r = −0.353) showed little or no correlation with the SRS-22 total score or any of its five domains. Significant inverse correlation was found between the UIV tilt angle at two years and the SRS-22 (r = −0.516). Lateral radiographs however showed little or no correlation between thoracic kyphosis (r = 0.043) and SRS-22.

Conclusion: The SRS-22 outcomes questionnaire does not correlate with most of the radiographic parameters commonly used by clinicians to assess patient outcome.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 86 - 86
1 Mar 2006
Arora J Ogden A
Full Access

Aim: To assess the medium term survival and radiological outcome of primary cemented modular Freeman Samuelson total knee replacement at Dumfries and Galloway Royal Infirmary, UK

Material and methods: 115 patients (118 knees), who underwent primary cemented modular Freeman Samu-elson total knee replacement from 1991 to1998, were reviewed retrospectively. Proximal cementing technique was used ti fix the metal backed tibial implant. The follow-up x-rays were also reviewed and presence of osteolysis, aseptic loosening and polyethylene wear was noted. The Knee Society radiological evaluation was used to record the osteolysis and the WOMAC score was used to evaluate functional outcome.

Results: The operation was performed for osteoarthritis (87), rheumatoid arthritis (23), psoriasis (4), Pagets disease (2), avascular necrosis (1) and gout (1). The average follow-up was 7.25 yrs (range 5–13 yrs). At the latest review 25 patients had died and 14 had undergone revision surgery. The indications for revision were aseptic loosening and polyethylene wear (3), osteolysis (3), infection (6), instability (1) and loosening of patellar component (1). Patella was resurfaced in 80 patients using press fit uncemented all-polyethylene component. Two patients with unreplaced patella underwent re-operation for patellar resurfacing due to anterior knee pain. Cumulative survival of the implant at 10 years was 93.4% for revision due to aseptic loosening or osteolysis and 86.8% for revision due to any cause. Radiolucent lines were observed in 22 patients. In 4 of these patients, the radiolucent lines were progressive and 3mm or more in size. Osteolytic lesions were seen in 10 patients. None of the patients with osteolysis or radiolucent lines were symptomatic. There was no statistical association between thickness of polyethylene and presence of osteolysis or occurrence of aseptic loosening (chi squared test)

Conclusion: Freeman Samuelson knee replacement provided good and predictable medium term outcome in our patients with tricompartmental arthritis of knee. The results of uncemented press fit all-polyethylene patellar replacement were also excellent. However, the high incidence of osteolysis even though asymptomatic, at an average follow-up of 7.25 yrs is a matter of some concern. Proximal cementing technique may lead to increased incidence of osteolysis and should be avoided in the modular Freeman Samuelson total knee replacement


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 424 - 424
1 Jul 2010
Vasireddy A Navadgi B Deo S Satish V Lowdon I
Full Access

Purpose of study: With the increasing demand for arthroplasty surgery, it is important to maintain a high quality of care. We describe a clinical governance framework for a simple, easy to implement method of assessing and monitoring radiological outcome following total knee arthroplasty.

Methods: We completed a two-year prospective study (January 2006 to December 2007 inclusive) of all total knee arthroplasty operations. This included 1,295 procedures, the majority of which were undertaken by two Consultant Surgeons and up to eight independent middle grade surgeons. The two Consultant Knee Surgeons assessed component position on standard post-operative weight-bearing antero-posterior and lateral knee radiographs on a weekly basis. They were blinded to both the patient and surgeon details, and used our own simple grading system, whose weighted Kappa variance showed ‘moderate’ interobserver (K = 0.41) and intraobserver reliability (K = 0.51). Our system comprised of only three ordinal scores, which were good (score of 1), acceptable (score of 2) and poor (score of 3).

Results: We provided individual surgeons with their results on a six-monthly basis. The average score for all the surgeons was good. The scores of the independent middle-grade surgeons were analysed by the Consultants, and feedback was provided in the form of formal advice and supervised surgical sessions. Repeat proportional analysis of their radiological scores showed significant improvements for all the individual surgeons (Pearson-Chi Square p value < 0.05).

Conclusions: Clinical governance is an important facet of excellence in medical practice. Our system allows continued prospective assessment of radiological outcome following total knee arthroplasty. By utilising such systems and ensuring an atmosphere of clinical excellence, we are able to employ more surgeons and undertake an increased workload, whilst maintaining high standards. This assessment tool can also be used to assess and appraise trainees during their progression.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 369 - 369
1 Sep 2012
Rodriguez Vega V Cecilia D Suarez L Jorge A Auñon I Rojo M Blanco D Guimera V Bravo B Garcia L Resines C
Full Access

Introduction

Distal radius fractures are one of the most common injuries attended in hospitals. Throughout the years the treatment has change from simple cast to ORIF.

Objectives

To compare the functional and radiographic results in the treatment of the distal intrarticular radial fractures treated by volar buttress plate (T plate AO® Synthes, Oberdorf, Suiza) and fixed volar angle locking plate (DVR® Depuy, Warsaw, Indiana, USA).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 72 - 72
1 May 2012
Hadi M Walker C Sheriff R Attar F Attar G
Full Access

Background & aim

There have been many operations described for the treatment of hallux valgus deformities and b ette done separately with variable success rates. Our aim is to radiologically assess the outcome following simultaneous osteotomies to the 1st and 5th metatarsals in symptomatic patients with splay foot. To our knowledge, this procedure has not been described in the literature yet.

Materials & method

9 symptomatic patients (12 feet) were included in the study. The pre-operative and post-operative X-rays were assessed and the hallux valgus angles, 1st and 2nd intermetatarsal angles, distal metatarsal articular angles (DMAA), 4th and 5th intermetatarsal angles, maximum widths of the 1st and 5th metatarsal heads and the maximum distance between 1st and 5th metatarsals were calculated. The improvement in the angles and distances post-operatively were then assessed for statistical significance using Non-parametric paired T tests.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 110 - 110
1 Feb 2012
Hussain N Freeman B Watkins R He S Webb J
Full Access

Our prospective observational study of patients treated for Thoracolumbar Adolescent Idiopathic Scoliosis (AIS) by anterior instrumentation aimed at investigating the correlation between the radiographic outcome and the recently-developed scoliosis research society self-reported outcomes instrument (SRS-22) which has been validated as a tool for self-assessment in scoliosis patients. Previous patient based questionnaires demonstrated poor correlation with the radiological parameters.

Materials and Methods

Pre-operative, post-operative and two years follow-up radiographs of 30 patients were assessed. Thirteen radiographic parameters including Cobb angles and balance were recorded. The percentage improvements for each were noted. The SRS-22 questionnaire was completed by all patients at final follow-up. Correlation was sought between each radiographic parameter, total SRS score and each of the five domains by quantifying Pearson's Correlation Coefficient (r).

Results

Percentage improvement in primary Cobb angle (r = 0.052), secondary Cobb angle (r = 0.165), apical vertebra translation of the primary curve (r = -0.353), thoracic kyphosis (r = 0.043) and lumbar lordosis (r = 0.147) showed little or no correlation with the SRS-22 total score and its five individual domains. Significant inverse correlation was found between the upper instrumented vertebra angle and at follow-up and SRS-22 (r = -0.516). The same was true for Sagittal plumb line shift at final follow up (r = -0.447).


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 781 - 786
1 Jun 2010
Zhao G Yamamoto T Ikemura S Motomura G Mawatari T Nakashima Y Iwamoto Y

We investigated the factors related to the radiological outcome of a transtrochanteric curved varus osteotomy in patients with osteonecrosis of the hip. We reviewed 73 hips in 62 patients with a mean follow-up of 12.4 years (5 to 31.1). There were 28 men and 34 women, with a mean age of 33.3 years (15 to 68) at the time of surgery. The 73 hips were divided into two groups according to their radiological findings: group 1 showed progression of collapse and/or joint-space narrowing; group 2 had neither progressive collapse nor joint-space narrowing. Both of these factors and the radiological outcomes were analysed by a stepwise discriminant analysis. A total of 12 hips were categorised as group 1 and 61 as group 2. Both the post-operative intact ratio and the localisation of the necrotic lesion correlated with the radiological outcome. The cut-off point of the postoperative intact ratio to prevent the progression of collapse was 33.6%, and the cut-off point to prevent both the progression of collapse and joint-space narrowing was 41.9%.

The results of this study indicate that a post-operative intact ratio of 33.0% is necessary if a satisfactory outcome is to be achieved after this varus osteotomy.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 332 - 332
1 Jul 2011
De Man H Sendi P Maurer TB Zimmerli W Graber P Ilchmann T Ochsner P
Full Access

Introduction: In treatment for prosthetic hip joint infection (PHJI), the advantages of a 1-stage exchange over the classic 2-stage approach are the lower morbidity and earlier rehabilitation. Secondly, a recently published treatment algorithm for PHJI using well-defined selection criteria for 1-stage exchange had a 85–100% rate of cure for infection. Patient satisfaction after hip surgery is highly influenced by the functional result. We hypothesized that in our used algorithm the functional and radiological outcomes after a 1-stage exchange due to an implant-associated infection would be similar to a matched control group of 1-stage exchange due to aseptic loosening.

Material and Methods: Twenty-two cases (21 patients), with PHJI according to a well-defined definition, after 1-stage exchange of the prosthesis strictly according to the algorithm, with index-surgery between april 1996 and october 2004, were included in the studygroup. Case-matching was performed with aseptic revised cases for previous surgery, type of implant, use of transfemoral osteotomy, Charnley score, duration of follow-up, age, and sex. Outcome measures were perioperatively complications, functional results (Harris hip score, limping, and use of walking support) at two years, and the occurrence of revision for any reason and radiological loosening at latest follow-up. All outcomes were compared between both groups and with the results of the two stage revisions in our cohort. Finally, the eradication of infection was scored.

Results: In 86% of the 1-stage group (n = 19) there was an event-free follow-up for ≥ 2 years. The mean Harris hip score was 84, the incidence of limping 20% and 10% required two crutches. Two stems were revised due to aseptic loosening. Both functional and radiological outcomes were not different from the matched control group.

In the 2-stage group (n = 50) results were lower but not significantly, with 80, 30% and 28% respectively, and 2 stems and 1 cup were revised due to aseptic loosening.

One case (after one stage) developed an infection with a different pathogen and one case (after two stage exchange) had a relaps of infection.

Conclusion: By using the identical surgical technique in both septic and aseptic revision hip surgery, functional results are comparable between groups. These results indicate that 1-stage exchange according to a strict algorithm leads to a successful outcome in both maintaining functional mobility and eradicating infection.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 421 - 421
1 Nov 2011
Cazeneuve J Hasssan Y Hilaneh A Kermad F Brunel A
Full Access

Synthesis and hemi-prosthesis give well known radiological results for acute proximal complex humeral fractures in elderly population. We wanted to expose the radiological outcome of the reverse concept in this indication.

From 1993 to 2008, forty four DELTA III were implanted for thirty three three-part and four-part displacements and eleven fracture-dislocations, in 3 males for 41 females, with an average age of seventy five years. The results were estimated with AP and LAMY profile Xrays.

Because of ten deceases and three moving, thirty one cases were reviewed with a mean follow-up of 6.3 years, range 1 to 15. The radiographs showed : two 2-mm thick borders on the glenoid at four and eight years with a scapular notch at 11 years and an aseptic loosening of the base plate at 12 years with a broken polar inferior screw. The patient underwent an easy surgical revision because of a fair bone stock. There was no wear of the polyethylene.

According to the NEROT classification, nineteen inferior scapular notches were observed with a mean occurrence time of 4.6 years. The seven type-1 notches appeared at a mean of 2 years and the five type-2 notches at a mean of 4.3 years. We observed four type-3 notches which reached the inferior screw at 5,6,7 and 8 years, and three type-4 notches which extended beyond the inferior screw at 6,7 and 8 year follow-up, respectively. There seem to be two distinct patters of notches: mechanical, stable proximal humeral bone loss because of an impingement between the humeral component and the inferior scapular pillar and biological, progressive in size, evolving over time with proximal humeral bone loss because of polyethylene disease; the longer the follow-up, the more severe the notch. Fourteen inferior spurs, stable after emergence, were reported with a mean occurrence time of 2.5 years range 1 to 6 years. One joint ossification occurred at 6 months and was stable at 6 year follow-up. The humeral results consisted in five medial (5,6,710, and 11 years) proximal bone looses and three bone-cement interface medial borders on the two thirds of the height of the stem at a mean follow-up of 5 years. In these eight cases, there was a notch associated. We reported one case of septic humeral loosening at 2 year follow-up.

For acute proximal humeral complex fractures in elderly population, when re-fixation of the tubercles on the classical orthopaedics devices is impossible, the use of a DELTA III prosthesis shows, with a mean follow-up of 6.3 years, worrying images in 70% of the cases.

These images are on the glenoid in 70% of the cases, appeared before seven years in 86% and are progressive in 50% of the cases. But, we have only one re-intervention for an aseptic loosening of the base plate at a twelve year evolution. New developments in design and bearing surfaces and a more long term results will probably provide more durable utilization of the reverse concept in this indication.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 220 - 220
1 May 2006
Raman MA Rai MA Marshall DT Crawford MR
Full Access

There are numerous surgical techniques described for cervical decompression for multilevel cervical stenosis. Cervical skip laminectomy is a new technique described by Japanese surgeons in 2000. The advantage of this procedure over the other conventional techniques is it addresses multilevel problem in a least traumatic way without need for instrumentation. It is also described to have lesser incidence of post operative axial symptoms, range of motion and loss of cervical lordosis.

We are presenting our prospective case series of 23 patients who had this procedure in our institution between 2002 and 2004. Of these 16 patients are at least 6 months from their operation. We performed clinical outcome measurements using SF12 questionnaires, pre and postoperative clinical assessment performed by independent surgeon and a specialist spinal physiotherapist. We also routinely performed pre and postoperative MRI scans to assess the adequacy of decompression (Done by our musculoskeletal radiologist).

Our study showed a good clinical and radiological outcome with this relatively simple new procedure. This has become our standard operation for our patients with multilevel cervical stenosis with cervical myelopathy.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 26 - 27
1 Jan 2004
Yugue I. Shiba K Uezaki N
Full Access

Purpose: Cervical laminoplasty has been used for the treatment of cervical arthrosic myelopathy in Japan. The purpose of this work was to assess clinical and radiological outcome at more than two years follow-up.

Material: Thirty-one patients underwent laminoplasty of three levels or more for cervical arthrosic myelopathy and were reviewed more than two years after surgery.

Methods: The Japanese Orthopaedic Association score was used to assess function preoperatively and at last follow-up. Preoperative and last follow-up standard strict lateral and flexion and extension x-rays of the cervical spine were available for all patients. The curvature was assessed on the lateral view in the neutral position (C2–C7 Cobb angle). Overall mobility was assessed on the dynamic views.

Results: The mean preoperative score was 9.7, improving to 138 at last follow-up (p < 0.0001, paired t test). Mean relative gain was 52.9%. The mean Cobb angle was 17° preoperatively and 8.9° at last follow-up. Cervical spine curvature and overall mobility had no influence on the score at last follow-up. The postoperative Cobb score was only influenced by the preoperative angle (p < 0.0001). There were no reoperations for instability.

Discussion: Guigui has demonstrated that mean loss of cervical lordosis in a series of extended laminectomies was 14°. In our series, mean loss of cervical lordosis was 8.1°. Laminoplasty enables a better preservation of cervical lordosis than laminectomy. Guigui also reported three patients requiring reoperation because of an unstable spine after laminectomy. Inversely, we did not have any cases requiring reoperation. During laminoplasty, a gutter is fashioned in a medial quarter of the articular masses to open the lamina, producing their fusion. This unexpected fusion diminishes overall mobility but also has a less destabilising effect on the spine than laminectomy.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 402 - 402
1 Nov 2011
Bergschmidt P Lohmann C Bader R Lukas C Ruether W Mittelmeier W
Full Access

The objective of this prospective duo-center study was to evaluate the clinical and radiological outcome of the unconstrained Multigen Plus total knee system (Lima Lto, San Daniele, Italy) with the new BIOLOXÒ Delta ceramic femoral component.

40 patients underwent cemented total knee arthroplasty in two university hospitals. Clinical evaluations were undertaken preoperatively and at 3 as well as 12 months postoperatively using the HSS-Score, WOMAC-Score and SF-36-Score. The radiological investigations included ant-post. radiographs (whole leg in two leg stance and lateral view of the knee) and patella tangential radiographs (Merchant view).

During 12 months follow-up three patients underwent revision surgery. One patient had to be revised due to infection after postoperative opening of the knee joint due to direct trauma. One patient sustained an osteosynthetic procedure due to periprosthetic fracture after trauma. In one patient a retropatellar replacement was inserted one year postoperatively. Implant related complications were not found. The mean preoperative HSS-Score amounted to 57.8±11.7 points. At 3 and 12 month follow-up the mean HSS-Score was 76.0±12.3 and 83.3±11.9 points respectively.

Therefore HSS, as well as WOMAC and SF-36 Score improved significantly from preoperativly to both postoperative evaluations (Wilcoxon-Test p< 0.002). Radio-lucent lines around the femoral ceramic component were found in six cases.

However, subsequent long-term studies must be carried out in order to prove the good early clinical results and to clarify if progression of radiolucent lines may influence the clinical outcome of the presented newly ceramic total knee system.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 454 - 454
1 Aug 2008
Freeman BJC Hussain N McKenna P Yau YH Leung Y Hegarty J Kerslake RW
Full Access

Aim: The clinical and radiological outcomes of a prospective randomised controlled trial comparing Femoral Ring Allografts (FRA) to Titanium Cages (TC) for circumferential fusion are presented.

Methods: Eighty-three patients were recruited fulfilling strict entry requirements (> 6 months chronic discogenic Low Back Pain (LBP), failure of conservative treatment, one or two level discographically-proven discogenic pain). Five patients were excluded on technical infringements (unable to insert TC or FRA). From 78 patients randomised, 37 received FRA and 41 received TC. Posterior stabilisation was achieved with translaminar or pedicle screws. Patients completed the Oswestry Disability Index (ODI), Visual Analogue Scale (VAS) for back and leg pain, the Short-Form 36 (SF-36) pre-operatively and 6, 12 and 24 months post-operatively. Assessment of fusion was made by a panel of 6 individuals examining radiographs taken at the same specified time points.

Results: Clinical outcomes were available for all 83 patients (mean follow-up 28 months, range 24–75). Baseline demographic data showed no statistical difference between groups (p< 0.05). For patients receiving FRA, mean VAS (back pain) improved 2.0 points (p< 0.01), mean ODI improved 15 points (p=< 0.01), and mean SF-36 scores improved by > 11 points in 6 of 8 domains (p< 0.03). For patients receiving TC, mean VAS improved 1.1 points (p=0.004), mean ODI improved 6 points (p=0.01), and SF-36 improved significantly in only two of eight domains. Revision procedures and complications were similar in both groups. For the FRA group, 27 levels were fused from a total of 42 assessed (64.2%). For the TC group, 33 levels were fused from a total of 55 assessed (60%). This difference was not statistically significant p> 0.2.

Conclusion: The use of FRA in circumferential lumbar fusion was associated with superior clinical outcomes when compared to those observed following the use of TC. Both groups had similar fusion rates.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 529 - 535
1 May 2019
Jacobs CA Kusema ET Keeney BJ Moschetti WE

Aims

The hypothesis of this study was that thigh circumference, distinct from body mass index (BMI), may be associated with the positioning of components when undertaking total hip arthroplasty (THA) using the direct anterior approach (DAA), and that an increased circumference might increase the technical difficulty.

Patients and Methods

We performed a retrospective review of prospectively collected data involving 155 consecutive THAs among 148 patients undertaken using the DAA at an academic medical centre by a single fellowship-trained surgeon. Preoperatively, thigh circumference was measured at 10 cm, 20 cm, and 30 cm distal to the anterior superior iliac spine, in quartiles. Two blinded reviewers assessed the inclination and anteversion of the acetabular component, radiological leg-length discrepancy, and femoral offset. The radiological outcomes were considered as continuous and binary outcome variables based on Lewinnek’s ‘safe zone’.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 67 - 67
1 Mar 2006
Al Hussainy H Saldahna K Farhan M
Full Access

Hydroxyapatite-coated acetabular cup were used in revision hip arthroplasty without using bone grafts or bone substitutes to achieve osseointegration in 30 consecutive hips (29 patients). The mean age was 72.5 years (range 54 to 88). Primary prosthesis was 14 Charnley’s, 12 Capital 3M, one Furlong, one Exeter and one MacKee Farrar. Indication for revision was aseptic loosening in 20, recurrent dislocation in four, periprosthetic fracture in two, prosthesis fracture in one, and three infected hips.

Patients were assessed clinically using Harris Hip Score, satisfaction questionnaire and quality of life SF 36 questionnaire, and radiologically using DeLee and Charnley, Harris-Barrack, and Hodgkinson’s Engh’s classification, and Bassetlaw Digital Scoring System (BDSS) that we have devised. The acetabular defects were assessed preoperatively using the American Academy of Orthopaedic Surgeons (AAOS) classification.

Mean follow up was 38.7 months (range 18.5–76.4). Ninety present of acetabular cups had preoperative radiolucency in all DeLee and Charnley’s zones. 26 hips (87%) had no superior or lateral cup migration. Two hips had 3 mm superior migration at one year then remained stable. Mean improvement of Harris hip score was 42.2. 83.3% of hips had no or slight pain at final follow up.

Five patients had dislocations one of which was recurrent that required acetabular cup revision. Two patients had postoperative foot drop that recovered fully. Two patients had postoperative wound infection that healed with antibiotics apart from one who died due to multi-organ failure. Four patients died due to unrelated causes.

Postoperative radiographs showed stable fixation of all acetabular cups. 83.3% of hips had no or slight pain at final follow up.

Early results show that stable fixation in revision hip surgery can be obtained with HAC acetabular cups without bone grafts or bony substitute.


To assess the efficacy of a combined orthoplastic approach to the management of severe grade III fractures of the lower limb, we looked at the functional and radiological outcome of 100 consecutive fractures from a specialist centre.

A prospective analysis was performed on 100 consecutive open tibial fractures (98 patients). An early decision was made by a specialist multidisciplinary team as to whether the injured limb was reconstructable.

In the reconstruction group there were 84 Gustilo grade IIIB/C injuries. Definitive skeletal stabilisation was most commonly with a circular frame (60%) or intramedullary nail (20%). The mean time to union was 26 weeks for diaphyseal fractures, 20 weeks for metaphyseal fractures and 10 weeks for ankle fractures. There was one aseptic non-union which is still undergoing treatment. The anterolateral thigh free flap was the most common soft tissue reconstruction used (42%). There were minimal surgical complications and only one free flap failure. Mean time to follow-up was 24 months. The mean limb functional score (modified enneking) was 83% of that of the normal limb and was not influenced by the site of fracture or type of fixation. The mean SF-36 score was 75 and there was a high return to employment (70%).

In the primary amputation group there were 16 grade IIIB/C injuries. Mean time to follow-up was 38 months. The mean SF-36 score for the below knee amputees was 58 and there was again a high return to employment (58%).

In the reconstruction group there is a 99% limb salvage rate with infection-free union to date and no delayed amputations. A higher return to functional activity/employment was achieved in the reconstruction group compared to the primary amputation group. Our results demonstrate that by using a combined orthoplastic approach in a specialist centre excellent results can be achieved for all patients presenting with severe open lower limb injuries.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 448 - 448
1 Aug 2008
Raman A Bhadra A Singh A Rai A Casey A Crawford R
Full Access

Aim: To compare the outcomes between two different surgical techniques for cervical myelopathy (skip laminectomy vs laminoplasty).

Methods: Cervical skip laminectomy is a new technique described by Japanese surgeons in 2000. The advantage of this procedure over the other conventional techniques is it addresses multilevel problem in a least traumatic way without need for instrumentation.

We are comparing the above two techniques with 25 patients in each group operated by 3 surgeons. The first group had conventional laminoplasty and the second group underwent the skip laminectomy. The groups were comparable in age, sex, pathology and clinical presentation. Both these group had clinical outcome measurements using SF 12 questionnaires, pre and postoperative clinical assessment with standard tools performed by independent surgeon and a specialist spinal physiotherapist. We also routinely performed pre and postoperative MRI scans to assess the adequacy of decompression.

Results and Conclusion: here was no significant difference in the outcome of these patients in terms of the operative technique, hospital stay, clinical and radiological outcome. However skip laminectomy is relatively a easier procedure to perform, while the laminoplasty does need instrumentation.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 468 - 474
1 Apr 2018
Kirzner N Zotov P Goldbloom D Curry H Bedi H

Aims

The aim of this retrospective study was to compare the functional and radiological outcomes of bridge plating, screw fixation, and a combination of both methods for the treatment of Lisfranc fracture dislocations.

Patients and Methods

A total of 108 patients were treated for a Lisfranc fracture dislocation over a period of nine years. Of these, 38 underwent transarticular screw fixation, 45 dorsal bridge plating, and 25 a combination technique. Injuries were assessed preoperatively according to the Myerson classification system. The outcome measures included the American Orthopaedic Foot and Ankle Society (AOFAS) score, the validated Manchester Oxford Foot Questionnaire (MOXFQ) functional tool, and the radiological Wilppula classification of anatomical reduction.


Bone & Joint 360
Vol. 12, Issue 5 | Pages 39 - 42
1 Oct 2023

The October 2023 Oncology Roundup. 360. looks at: Are pathological fractures in patients with osteosarcoma associated with worse survival outcomes?; Spotting the difference: how secondary osteosarcoma manifests in retinoblastoma survivors versus conventional cases; Accuracy of MRI scans in predicting intra-articular joint involvement in high-grade sarcomas around the knee; Endoprosthetic reconstruction for lower extremity soft-tissue sarcomas with bone involvement; Local relapse of soft-tissue sarcoma of the extremities or trunk wall operated on with wide margins without radiation therapy; 3D-printed, custom-made prostheses in patients who had resection of tumours of the hand and foot; Long-term follow-up for low-grade chondrosarcoma; Evaluation of local recurrence and diagnostic discordance in chondrosarcoma patients undergoing preoperative biopsy; Radiological scoring and resection grade for intraosseous chondrosarcoma


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_4 | Pages 2 - 2
8 Feb 2024
Dixon JE Rankin IA Sciberras N Khan LAK Barker SL Cairns DA Kumar K
Full Access

In recent years, use of anatomic stemless total shoulder arthroplasty (AsTSA) has increased. Despite evidence to suggest good mid-term results at 2-year follow-up there is a paucity of evidence for longer term follow-up. This study aimed to investigate outcomes at a minimum of 5 years post-operatively following primary AsTSA. This study is a retrospective case series of all patients who underwent a Mathys Affinis AsTSA from July 2010 (first case) to August 2018 (to allow minimum 5-year follow-up). Clinical outcomes included revision rate, range of motion and patient reported outcomes (Oxford Shoulder Score and Numerical Satisfaction Score). Radiological outcome was assessment of radiolucent lines for Lazarus grading. A total of 105 stemless TSAs were implanted. Five patients underwent revision (4.8%). Seventy-five AsTSA's were included in the final study for analysis of 5-year outcomes. Median follow-up time was 6.1 years. Median age was 69 years old and 81% were female. Oxford shoulder score showed a range of 18 to 48, with a median score of 47. Satisfied or very Satisfied was selected in 94.37%. Median range of motion assessments showed forward elevation 160°, abduction 150°, external rotation 40°, and mode internal rotation was to the lumbar spine. No glenoid lucency was present in 79.7%. There were 9.5% with Lazarus Grade 1 lucency, 5.4% with Lazarus Grade 2, and 5.4% Lazarus Grade 3. No humeral lucency was observed. This cohort study demonstrates promising clinical and radiological outcomes for the Mathys Affinis Stemless TSA at minimum 5 years post-operatively


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 46 - 52
1 Jul 2021
McGoldrick NP Fischman D Nicol GM Kreviazuk C Grammatopoulos G Beaulé PE

Aims. The aim of this study was to radiologically evaluate the quality of cement mantle and alignment achieved with a polished tapered cemented femoral stem inserted through the anterior approach and compared with the posterior approach. Methods. A comparative retrospective study of 115 consecutive hybrid total hip arthroplasties or cemented hemiarthroplasties in 110 patients, performed through anterior (n = 58) or posterior approach (n = 57) using a collarless polished taper-slip femoral stem, was conducted. Cement mantle quality and thickness were assessed in both planes. Radiological outcomes were compared between groups. Results. No significant differences were identified between groups in Barrack grade on the anteroposterior (AP) (p = 0.640) or lateral views (p = 0.306), or for alignment on the AP (p = 0.603) or lateral views (p = 0.254). An adequate cement mantle (Barrack A or B) was achieved in 77.6% (anterior group, n = 45) and in 86% (posterior group, n = 49), respectively. Multivariate analysis revealed factors associated with unsatisfactory cement mantle (Barrack C or D) included higher BMI, left side, and Dorr Type C morphology. A mean cement mantle thickness of ≥ 2 mm was achieved in all Gruen zones for both approaches. The mean cement mantle was thicker in zone 7 (p < 0.001) and thinner in zone 9 for the anterior approach (p = 0.032). Incidence of cement mantle defects between groups was similar (6.9% (n = 4) vs 8.8% (n = 5), respectively; p = 0.489). Conclusion. An adequate cement mantle and good alignment can be achieved using a collarless polished tapered femoral component inserted through the anterior approach. Cite this article: Bone Joint J 2021;103-B(7 Supple B):46–52


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_27 | Pages 29 - 29
1 Jul 2013
Harrison W Harrison D
Full Access

Total disc replacement (TDR) is the gold standard for lumbar degenerative disc disease in selected patient groups. Traditional TDR designs benefit from a wealth of literature and use a polyethylene inlay pseudo-disc between two metal endplates. There is scarce literature for novel monomodular implants that form an artificial construct of woven annulus and central nucleus, providing physiological motion preservation. The aim was to compare the evolving changes to radiological position between monomodular and traditional implants and assess the relationship of migration with bone densitometry. This retrospective series of consecutive patients undergoing TDR under a single surgeon recorded demographics, co-morbidities, previous surgery and clinical outcomes. Measurements of endplate subsidence, lordosis and spondylolisthesis taken from weight-bearing erect x-rays at 0, 3, 6 and 12 months. Radiological outcomes were compared against CT bone densitometry. 33 monomodular and 13 traditional implants. Mean age 40 years. All patients had degenerative disc disease. Monomodular and traditional implants were as likely to develop lordosis (p=0.32), endplate subsidence (p=0.78) or spondylolisthesis (p=0.98). Comparison between endplate subsidence and low bone densitometry were insignificant (p=0.47). Developing lordosis in the monomodular implant was related to low bone density; mean 134vs.184mg/cm. 3. (p=0.018). Three monomodular implants developed a posterior hinge after migrating into lordosis. One traditional implant dislocated, requiring emergency fusion. Radiological outcomes are comparable between traditional and monomodular implants. The larger endplate-footprint of the monomodular implant did reduce subsidence. Monomodular implants pivoting on a posterior hinge may fail early. Bone densitometry may identify patients who will drift into lordosis


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 38 - 38
1 Apr 2019
Lazennec JY Rakover JP Rousseau MA
Full Access

INTRODUCTION. Lumbar total disc replacement (TDR) is an alternative treatment to avoid fusion related adverse events, specifically adjacent segment disease. New generation of elastomeric non-articulating devices have been developed to more effectively replicate the shock absorption and flexural stiffness of native disc. This study reports 5 years clinical and radiographic outcomes, range of motion and position of the center of rotation after a viscoelastic TDR. Material and methods. This prospective observational cohort study included 61 consecutive patients with monosegmental TDR. We selected patients with intermediate functional activity according to Baecke score. Hybrid constructs had been excluded. Only cases with complete clinical and radiological follow-up at 3, 6, 12, 24 and 60 months were included. Mean age at the time of surgery was 42.8 +7.7 years-old (27–60) and mean BMI was 24.2 kg/m² +3.4 (18–33). TDR level was L5-S1 in 39 cases and L4-L5 in 22 cases. The clinical evaluation was based on Visual Analog Scale (VAS) for pain, Oswestry Disability Index (ODI) score, Short Form-36 (SF36) including physical component summary (PCS) and mental component summary (MCS) and General Health Questionnaire GHQ28. The radiological outcomes were range of motion and position of the center of rotation at the index and the adjacent levels and the adjacent disc height changes. Results. There was a significant improvement in VAS (3.3±2.5 versus 6.6±1.7, p<0.001), in ODI (20±17.9 versus 51.2±14.6, p<0.001), GHQ28 (52.6±15.5 versus 64.2±15.6, p<0.001), SF 36 PCS (58.8±4.8 versus 32.4±3.4, p<0.001) and SF 36 MCS(60.7±6 versus 42.3±3.4, p<0.001). Additional surgeries were performed in 5 cases. 3 additional procedures were initially planified in the surgical program: one adjacent L3-L5 ligamentoplasty above a L5S1 TDR and two L5S1 TDR cases had additional laminectomies. Fusion at the index level was secondary performed in 2 L4L5 TDR cases but the secondary posterior fusion did not bring improvement. In the 56 remaining patients none experienced facet joint pain. One patient with sacroiliac pain needed local injections. Radiological outcomes were studied on 56 cases (exclusion of 5 cases with additional surgeries). The mean location centers of the index level and adjacent discs were comparable to those previously published in asymptomatic patients. According to the definition of Ziegler, all of our cases remained grade 0 for disc height (within 25% of normal). Discussion. The silent block design of LP-ESP provides an interesting specificity. It could be the key factor that makes the difference regarding facets problems and instability reported with other implants experimentally or clinically. Unfortunately no other comparative TDR series are available yet in the literature. Conclusion. This series reports significant improvement in mid-term follow up after TDR which is consistent with previously published studies but with a lower rate of revision surgery and no adjacent level disease pathologies. The radiographic assessment of the patients demonstrated the quality of functional reconstruction of the lumbar spine after LP ESP viscoelastic disc replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 58 - 60
1 Nov 2012
Munro JT Garbuz DS Masri BA Duncan CP

Tapered, fluted, modular, titanium stems have a long history in Europe and are increasing in popularity in North America. We have reviewed the results at our institution looking at stem survival and clinical outcomes. Radiological outcomes and quality of life assessments have been performed and compared to cylindrical non-modular cobalt chromium stems. Survival at five years was 94%. This fell to 85% at ten years due to stem breakage with older designs. Review of radiology showed maintenance or improvement of bone stock in 87% of cases. Outcome scores were superior in tapered stems despite worse pre-operative femoral deficiency. Tapered stems have proved to be a useful alternative in revision total hip arthroplasty across the spectrum of femoral bone deficiency


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 126 - 126
1 May 2016
Laky B Heuberer P Koelblinger R Kriegleder B Anderl W Pauzenberger L
Full Access

Hemi shoulder arthroplasty is a rather successful procedure although revision surgery due to secondary glenoid erosion is reported in more than 25%. The downside of common shoulder arthroplasty is that in a deltopectoral approach the subscapularis tendon needs to be detached for exposure of the humeral head. Refixation of subscapularis tendon is associated with a retear rate of 4%, furthermore with progressing fatty muscle infiltration and loss of function. In case of revision surgery a second subscapularis tendon detachment is even more associated with worse function. Thus, arthroscopic humeral head resurfacing is an expedient alternative for minimal invasive humeral head arthroplasty without compromising subscapularis function. The purpose of this study was to report first clinical and subjective results after arthroscopic-assisted resurfacing of the humeral head. For this prospective case series, 24 patients (7 females, 17 males; mean age 59 years, range 42–73 years) undergoing arthroscopic-assisted partial shoulder resurfacing with the partial eclipse prosthesis were included in the study. Clinical conditions and subjective assessments were evaluated before surgery and annually thereafter using the Constant score (CS), active range of motion (ROM), visual analog scale (VAS) for pain, and the American Shoulder and Elbow Surgeons scale (ASES). Radiological outcomes and major complications were monitored. The mean CS for all patients improved significantly from 51 points preoperatively to 83 points 12 months after surgery (p=0.005). Trends towards increasing ROMs were detected. Subjective scores significantly improved from baseline to the 1-year follow-up (VAS: from 6.4 to 2.5, p=0.010; ASES: from 47 to 76, p=0.026). The majority of patients (88%) stated that they would undergo the procedure again. Revisions were indicated in 17% due to progression of osteoarthritis. Arthroscopic-assisted partial humeral head resurfacing as a minimal invasive procedure with the advantages of bone stock preservation and intact subscapularis tendon allowed immediate postoperative active mobilization and provided significant improvements in subjective outcome. In case of revision surgery a primary situation was encountered with postoperative results comparable to primary arthroplasty


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 902 - 908
1 Jul 2022
Hsu P Lee C Lin S Kuo KN Wu K Wang T

Aims

The aim of this study was to compare outcomes of guided growth and varus osteotomy in treating Kalamchi type II avascular necrosis (AVN) after open reduction and Pemberton acetabuloplasty for developmental dysplasia of the hip (DDH).

Methods

This retrospective study reviewed patients undergoing guided growth or varus osteotomy for Kalamchi type II AVN between September 2009 and January 2019. All children who had undergone open reduction and Pemberton acetabuloplasty for DDH with a minimum two-year follow-up were enrolled in the study. Demographic and radiological data, which included the head-shaft angle (HSA), neck-shaft angle (NSA), articulotrochanteric distance (ATD), Sharp angle (SA), and lateral centre-edge angle (LCEA) at baseline, two years, and at the extended follow-up, were compared. Revision rates were evaluated. Clinical outcomes using the Harris Hip Score were assessed two years postoperatively.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 898 - 906
1 Sep 2024
Kayani B Wazir MUK Mancino F Plastow R Haddad FS

Aims

The primary objective of this study was to develop a validated classification system for assessing iatrogenic bone trauma and soft-tissue injury during total hip arthroplasty (THA). The secondary objective was to compare macroscopic bone trauma and soft-tissues injury in conventional THA (CO THA) versus robotic arm-assisted THA (RO THA) using this classification system.

Methods

This study included 30 CO THAs versus 30 RO THAs performed by a single surgeon. Intraoperative photographs of the osseous acetabulum and periacetabular soft-tissues were obtained prior to implantation of the acetabular component, which were used to develop the proposed classification system. Interobserver and intraobserver variabilities of the proposed classification system were assessed.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 72 - 81
1 Jan 2023
Stake IK Ræder BW Gregersen MG Molund M Wang J Madsen JE Husebye EE

Aims

The aim of this study was to compare the functional and radiological outcomes and the complication rate after nail and plate fixation of unstable fractures of the ankle in elderly patients.

Methods

In this multicentre study, 120 patients aged ≥ 60 years with an acute unstable AO/OTA type 44-B fracture of the ankle were randomized to fixation with either a nail or a plate and followed for 24 months after surgery. The primary outcome measure was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score. Secondary outcome measures were the Manchester-Oxford Foot Questionnaire, the Olerud and Molander Ankle score, the EuroQol five-dimension questionnaire, a visual analogue score for pain, complications, the quality of reduction of the fracture, nonunion, and the development of osteoarthritis.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_2 | Pages 17 - 17
1 Jan 2014
Perera A Beddard L Marudunayagam A
Full Access

Background:. The Chevron osteotomy is straightforward, requires less dissection and allows earlier rehabilitation than some other osteotomies. However it is generally perceived as unsuitable for severe deformities even though a 2012 meta-analysis and an earlier RCT failed to show any advantage of the scarf over the chevron. We aim to assess the correctability of severe HV comparing the correction, the clinical outcomes and complications of the Chevron osteotomy with other techniques employed in a consecutive series. Methodology:. We reviewed a series of 92 cases of severe hallux valgus (IMA >17° regardless of the HVA). The follow-up period varied from 1 to 4 years. Pre-operative x-rays and final post-operative weight-bearing x-rays were performed. Outcome scores (MOXFQ and AOFAS), IMA, HVA and foot width were collected. Complications were monitored. Results:. There were 97 cases of severe hallux valgus performed during the study period, 55 were treated with a large-shift modified Chevron osteotomy, 42 with a number of other techniques that included Ludloff, Basal or Scarf osteotomy and also fusion in the form of a Lapidus or 1. st. MTP. The average pre-operative measurements were IMA of 19.1°, HVA of 40°, osseous forefoot width of 93.2 mm and the forefoot: hindfoot ratio was 3.11. Post-operatively the measurements were IMA of 9.2 and HVA of 9.76, the osseous forefoot width was 82.8 mm and the forefoot: hindfoot ratio was 2.57. Radiological outcomes for the Chevrons were similar to the alternative techniques though the rate of recovery was better. There is an increase in the rate of screw removal after a large shift Chevron osteotomy, reasons for this are discussed. Conclusion:. The Chevron osteotomy is successful in the management of severe hallux valgus. It has the advantage of being a stable osteotomy that permits immediate weight-bearing and movement of the MTP joint


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 330 - 330
1 Mar 2013
Sim JA
Full Access

During the ligament balancing for the severe medial contracture in varus knee TKA, complete distal release of the medial collateral ligament (MCL) or medial epicondylar osteotomy can be necessary in a large amount of correction. This study reviewed retrospectively 8 cases of complete distal release of the MCL (group 1) and 11 cases of medial epicondylar osteotomy (group 2) which was used to correct the severe medial contracture. In the complete distal release of the MCL, we performed the repair and used the brace for medial stability. The mean ages were 71.1-year-old and 71.5-year-old, respectively. The mean follow-up periods were 41.1 months and 21.9 months, respectively. Clinical outcome measures included Knee Society score (KSS), Function scrore (FS), and range of motion (ROM) at final follow up. Radiological outcomes measured medial instability by valgus stress radiograph at 3 months after operation and final follow up. There were no significant differences in clinical results between both two groups, for KSS (95.1 vs 91.1), FS (82.5 vs 88.2), and ROM (114.4Ëš vs 118.8Ëš). However, the medial instability of group 1 was larger than that of group 2 in the valgus stress radiograph (Figure 1). In terms of the medial stability, medial epicondylar osteotomy might be better than complete distal release of the MCL in varus TKA. Even though some some stability was obtained by MCL repair and bracing in complete distal release of the MCL, the medial instability was still remained. However, medial epicondylar osteotomy could give constant medial stability overall


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 93 - 93
1 Sep 2012
Van Der Maas J Verdonk P Tampere T Almqvist F Verdonk R
Full Access

Background. There is growing evidence in literature that meniscal allograft transplantation performed with the right indications results in significant pain relief and functional improvement of the involved joint. Long-term data on clinical and radiological outcome are however scarce. Methods. We evaluated 89 transplants (53 lateral and 36 medial) in 87 patients. Mean time of follow-up was 15,5 ± 2,85 years (range 9,9–20,4), mean age at surgery was 35,2 years (range 22–50). Clinically, the patients were evaluated using a KOOS, SF-36, HSS, VAS, Tegner and Lysholm score. HSS scores were compared to pre-operative and mid-term follow-up data. Each patient received radiographs (AP, profile and Rosenberg view). Radiological outcome parameters were joint space width narrowing and Fairbank changes and were scored according to IKDC. Failures were defined as patients who were converted to an arthroplasty. Results. HSS-scores improved significantly from 119 ± 27pre-operatively to 160 ± 40 at long-term follow-up. Lysholm-score was 69 ± 22, which was defined as a fair result. Mean VAS-score was 3,4 ± 3, mean Tegner was 4 ± 2. There were no significant differences between following subgroups: left or right knee, medial or lateral allograft, combined procedure with a high tibial osteotomy and male or female. Nine (25%) of the thirty-six medial and ten (19%) of the fifty-three lateral grafts failed after a mean of 9,9 years. Conclusions. Transplantation of a viable meniscal allograft can significantly relieve pain and improve function of the knee joint. Survival analysis showed that this beneficial effect remained in approximately 70% of the patients at fifteen years. This study proves that meniscal allograft transplantation is a beneficial procedure to postpone total knee arthroplasty for more than 10 years in young active patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 23 - 23
1 Sep 2012
Lee P Smitesh P Hua J Gupta A Hashemi-Nejad A
Full Access

Introduction. Many patients who had previous proximal femoral osteotomies develop deformities that may not be amenable to total hip replacement (THR) with standard off-the-shelf femoral stems. Previous studies have shown high revision rates (18% at 5–10 years follow-up). Computer-assisted-design computer-assisted-manufacture (CAD-CAM) femoral stems are indicated but the results are not known. We assessed the clinical results of THR using CAD-CAM femoral stems specifically for this group of patients. Methods. We included patients with previous proximal femoral osteotomy and significant deformity who underwent THR with CAD-CAM femoral stem operated by the senior author (AHN) from 1997 with a minimum of 5 years follow-up. We noted revision rates, associated complications and functional outcome. Radiological outcomes include assessment for loosening defined as development of progressive radiolucent lines around implant or implant migration. Results. We included 54 patients (57 THRs) at a mean age of 32 years (range 19 to 49) with a mean follow-up of 9.1 years (range 5.9–12.8). There was 2 (3.5%) stem revision for loosening. Seven polyethylene liners were revised because of eccentric wear/osteolysis after a mean of 10 years (range 7–11.5) but there was no associated radiological stem loosening. Other associated complications include 2 (3.5%) intraoperative femur fractures, 1 (1.8%) infection treated with antibiotics and 1 (1.8%) greater trochanteric fracture non-union. At the last follow-up review, the mean Oxford hip score was 35 (11–48) and the mean UCLA activity score was 5.1 (3–10). Conclusion. In contrast to previous studies that have shown high revision rates for THR in patients with previous proximal femoral osteotomy and osteotomy, the use of CAD-CAM hip stems has shown good mid- to long-term clinical outcomes with a considerably lower revision rate


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 249 - 249
1 May 2009
Johnston D Al Yamani M Beaupre L Huckell JR
Full Access

We compared self-reported pain and function, complications and revision rates, and radiographic outcomes of hydroxylapatite(HA) or cemented tibial fixation in the first five years following primary total knee arthroplasty. This was a randomised clinical trial of eighty-one patients. Prospective, randomised clinical trial. Patients less than seventy years of age with non-inflammatory knee arthritis. Eighty-one patients were randomised at the time of surgery to receive HA or cemented tibial fixation. Subjects were evaluated preoperatively, six months, one and five years postoperatively by a physical therapist who was blinded to group allocation. X-rays were evaluated by an experienced arthroplasty surgeon who did not perform any of the surgeries. Self-reported pain and function, the primary outcomes, were measured by the Western Ontario McMaster (WOMAC) Osteoarthritis Index and the RAND 36-item Health Services Inventory (RAND-36). Complications and revision rates were determined through hospital record review and at each patient evaluation. The Knee Society Radiological Score was used to evaluate plain radiographs at each assessment. There was slightly more pain in HA group at six months as measured by both the WOMAC and RAND-36, a difference that disappeared by the one-year assessment. There were no differences in function, radiographic findings or complications at any time. Finally, no subjects required revision of the tibial prosthesis during the study. Overall, no significant differences were seen between groups. The initial difference in self-reported pain disappeared by twelve-months postoperatively. At five-years postoperatively, there is no advantage to HA tibial fixation over cemented tibial fixation


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 711 - 716
1 Jun 2023
Ali MS Khattak M Metcalfe D Perry DC

Aims

This study aimed to evaluate the relationship between hip shape and mid-term function in Perthes’ disease. It also explored whether the modified three-group Stulberg classification can offer similar prognostic information to the five-group system.

Methods

A total of 136 individuals aged 12 years or older who had Perthes’ disease in childhood completed the Patient-Reported Outcomes Measurement Information System (PROMIS) Mobility score (function), Nonarthritic Hip Score (NAHS) (function), EuroQol five-dimension five-level questionnaire (EQ-5D-5L) score (quality of life), and the numeric rating scale for pain (NRS). The Stulberg class of the participants’ hip radiographs were evaluated by three fellowship-trained paediatric orthopaedic surgeons. Hip shape and Stulberg class were compared to PROM scores.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 137 - 137
1 May 2011
Jayakumar P Tibrewal S Prime M Sriranganathan R Basu I Vemulapalli K Banan H
Full Access

Introduction: The proximal femoral nail antirotation (PFNA) system is a cephalomedullary device originally designed to contend with the challenge of unstable tro-chanteric femoral fractures with the novel helical blade component aimed at limiting femoral head limiting cutout. We demonstrate its use in a variety of cases. Methods: This is a prospective study of 370 consecutive patients treated with short and long PFNA systems at a single center with 1-year follow-up. The device was used for unstable trochanteric femoral fractures (AO-classification 31. A.2 and A.3), prophylactic and definitive fixation of pathological fractures and high energy femoral fractures for a wide age range (19–101 years). Clinical outcome involved assessment of general mobility & function, operative and post-operative parameters & complications. Radiological outcome involved assessment of blade tip-apex distance, nail tip-femoral scar distance and distal locking configurations. Results: 17% died within the follow-up period. 72% achieved their pre-trauma mobility status and nearly all fractures healed within 6 months including those in over 85 years. Of 18 problematic cases, serious complications included deep infection, loss of proximal reduction, ipsilateral femoral shaft fracture and periprosthetic supra-condylar fracture. There were no cases of acetabular penetration or blade cut-out. Short PFNA was associated with the majority of femoral shaft fractures and the only significant finding regarding instrumentation. Discussion: This study supports long PFNA design theory demonstrating adequate purchase in the femoral head-neck zone, shown by lack of cut-out. Positive results have been demonstrated in a variety of cases making it a useful option in fractures in all ages and indications alongside unstable trochanteric configurations


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 128 - 128
1 Dec 2013
Moon Y Lim H Ko KR Lee KH So S Seo J
Full Access

Background:. The safety implications of achieving high flexion after TKA and the use of high flexion prostheses remain issues of concern. It is possible that different designs have different clinical and radiological results and complications, such as, early aseptic loosening. However, little information is available on the clinical results of TKAs performed using single-radius, high-flex posterior stabilized design. Accordingly, this study was undertaken to document results of single-radius, high-flex posterior stabilized TKAs with minimum 7-year follow-up. Methods:. From April 2003 to February 2006, 308 patients (455 knees) underwent TKA using single-radius, high-flex posterior stabilized design and among those patients, 251 patients (388 knees) included in this study who were able to be followed up for a minimum 7 year. Clinical results were evaluated using Knee Society Knee scores (KSKS) and Knee Society Function scores (KSFS) at last follow-up. The passive knee flexion was measured using a goniometer before and after surgery. The survival rate of the implants and implant-specific complications such as osteolysis or loosening were investigated. The osteolysis or loosening around the components was recorded according to the Knee Society Radiological scoring System. Results:. Mean Knee Society Knee score improved from 48.2 preoperatively to 96.8 postoperatively and mean Function score improved from 49.7 preoperatively to 74.2 postoperatively, respectively. The average range of motion (ROM) improved from 112.7° preoperatively to 131.5° postoperatively. Postoperative mechanical axis deviation (MAD) was within −3° to 3°, in 316 knees (81.4%). Non-progressive osteolysis was observed at zone 4 of the femoral component in eight knees (2.06%), at zone 3 of the tibial component in one knee (0.26%), at zone 2 of the tibial component in two knees (0.52%), and at zone 1 of the tibial component in thirteen knees (3.35%) in anteroposterior view. Two cases were revised due to infection and recurrent hemarthrosis. However, no complications, like early aseptic loosening, that have been associated with high flexion designs were observed. Conclusions:. Clinical results for TKAs conducted using a single-radius, high-flex posterior stabilized design with a minimum 7-year follow-up were favorable. Furthermore, no high flexion implant-specific complications such as early aseptic loosening were encountered


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 160 - 160
1 Mar 2010
Sim JA Lee BK Yang SH
Full Access

The objective of this study was to compare the results between MCL complete detachment and medial epicondylar osteotomy for severe varus deformity in TKA. We reviewed 8 cases of MCL complete detachment (group I) and 11 cases of medial epicondylar osteotomy (group II) for severe varus deformity (from February 2001 to December 2006). In MCL complete detachment, we performed the reattachment of MCL and putting on the brace. Clinical outcome measures included Knee Society score (KSS), Function scrore (FS), and range of motion (ROM). Radiological outcomes were medial instability as determined by valgus stress radiograph, alignment by whole extremity radiograph. Group I had 4 neutral and 4 varus alignment and group II had 9 neutral, 1 varus and 1 valgus alignment. There were no significant differences in clinical results between both two groups, for KSS (95.1 vs 91.1), FS (82.5 vs 88.2), and ROM (0.6–115° vs 0–118.8°). However, there were significant differences in medial instability compared normal side. Group I had the differences of 4.1 degree at postoperative 3 months and 2.1 degree at final follow-up. Group II had 0.9 degree at postoperative 3 months and 0.4 degree at final follow-up. Medial epicondylar osteotomy for severe varus deformity in TKA could be useful technique for medial stability of the knee regardless of the alignment


Bone & Joint Open
Vol. 4, Issue 12 | Pages 964 - 969
19 Dec 2023
Berwin JT Duffy SDX Gargan MF Barnes JR

Aims

We assessed the long-term outcomes of a large cohort of patients who have undergone a periacetabular osteotomy (PAO), and sought to validate a patient satisfaction questionnaire for use in a PAO cohort.

Methods

All patients who had undergone a PAO from July 1998 to February 2013 were surveyed, with several patient-reported outcome measures (PROMs) and radiological measurements of preoperative acetabular dysplasia and postoperative correction also recorded. Patients were asked to rate their level of satisfaction with their operation in achieving pain relief, restoration of activities of daily living, ability to perform recreational activity, and their overall level of satisfaction with the procedure.


Bone & Joint Open
Vol. 3, Issue 11 | Pages 885 - 893
14 Nov 2022
Goshima K Sawaguchi T Horii T Shigemoto K Iwai S

Aims

To evaluate whether low-intensity pulsed ultrasound (LIPUS) accelerates bone healing at osteotomy sites and promotes functional recovery after open-wedge high tibial osteotomy (OWHTO).

Methods

Overall, 90 patients who underwent OWHTO without bone grafting were enrolled in this nonrandomized retrospective study, and 45 patients treated with LIPUS were compared with 45 patients without LIPUS treatment in terms of bone healing and functional recovery postoperatively. Clinical evaluations, including the pain visual analogue scale (VAS) and Japanese Orthopaedic Association (JOA) score, were performed preoperatively as well as six weeks and three, six, and 12 months postoperatively. The progression rate of gap filling was evaluated using anteroposterior radiographs at six weeks and three, six, and 12 months postoperatively.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 993 - 999
1 Sep 2023
van Delft EAK van Bruggen SGJ van Stralen KJ Bloemers FW Sosef NL Schep NWL Vermeulen J

Aims

There is no level I evidence dealing with the optimal period of immobilization for patients with a displaced distal radial fracture following closed reduction. A shorter period might lead to a better functional outcome due to less stiffness and pain. The aim of this study was to investigate whether this period could be safely reduced from six to four weeks.

Methods

This multicentre randomized controlled trial (RCT) included adult patients with a displaced distal radial fracture, who were randomized to be treated with immobilization in a cast for four or six weeks following closed reduction. The primary outcome measure was the Patient-Rated Wrist Evaluation (PRWE) score after follow-up at one year. Secondary outcomes were the abbreviated version of the Disability of Arm, Shoulder and Hand (QuickDASH) score after one year, the functional outcome at six weeks, 12 weeks, and six months, range of motion (ROM), the level of pain after removal of the cast, and complications.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 182 - 188
1 Feb 2024
Gallego JA Rotman D Watts AC

Aims

Acute and chronic injuries of the interosseus membrane can result in longitudinal instability of the forearm. Reconstruction of the central band of the interosseus membrane can help to restore biomechanical stability. Different methods have been used to reconstruct the central band, including tendon grafts, bone-ligament-bone grafts, and synthetic grafts. This Idea, Development, Exploration, Assessment, and Long-term (IDEAL) phase 1 study aims to review the clinical results of reconstruction using a synthetic braided cross-linked graft secured at either end with an Endobutton to restore the force balance between the bones of the forearm.

Methods

An independent retrospective review was conducted of a consecutive series of 21 patients with longitudinal instability injuries treated with anatomical central band reconstruction between February 2011 and July 2019. Patients with less than 12 months’ follow-up or who were treated acutely were excluded, leaving 18 patients in total. Preoperative clinical and radiological assessments were compared with prospectively gathered data using range of motion and the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) functional outcome score.


Bone & Joint 360
Vol. 11, Issue 5 | Pages 20 - 23
1 Oct 2022


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 475 - 481
1 May 2024
Lee M Lee G Lee K

Aims

The purpose of this study was to assess the success rate and functional outcomes of bone grafting for periprosthetic bone cysts following total ankle arthroplasty (TAA). Additionally, we evaluated the rate of graft incorporation and identified associated predisposing factors using CT scan.

Methods

We reviewed a total of 37 ankles (34 patients) that had undergone bone grafting for periprosthetic bone cysts. A CT scan was performed one year after bone grafting to check the status of graft incorporation. For accurate analysis of cyst volumes and their postoperative changes, 3D-reconstructed CT scan processed with 3D software was used. For functional outcomes, variables such as the Ankle Osteoarthritis Scale score and the visual analogue scale for pain were measured.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 29 - 34
1 Jan 2023
Fransen BL Bengoa FJ Neufeld ME Sheridan GA Garbuz DS Howard LC

Aims

Several short- and mid-term studies have shown minimal liner wear of highly cross-linked polyethylene (HXLPE) in total hip arthroplasty (THA), but the safety of using thinner HXLPE liners to maximize femoral head size remains uncertain. The objective of this study was to analyze clinical survival and radiological wear rates of patients with HXLPE liners, a 36 mm femoral head, and a small acetabular component with a minimum of ten years’ follow-up.

Methods

We retrospectively identified 55 patients who underwent primary THA performed at a single centre, using HXLPE liners with 36 mm cobalt-chrome heads in acetabular components with an outer diameter of 52 mm or smaller. Patient demographic details, implant details, death, and all-cause revisions were recorded. Cox regression and Kaplan-Meier survival was used to determine all-cause and liner-specific revision. Of these 55 patients, 22 had a minimum radiological follow-up of seven years and were assessed radiologically for linear and volumetric wear.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 705 - 712
1 Jul 2024
Karlsson T Försth P Öhagen P Michaëlsson K Sandén B

Aims

We compared decompression alone to decompression with fusion surgery for lumbar spinal stenosis, with or without degenerative spondylolisthesis (DS). The aim was to evaluate if five-year outcomes differed between the groups. The two-year results from the same trial revealed no differences.

Methods

The Swedish Spinal Stenosis Study was a multicentre randomized controlled trial with recruitment from September 2006 to February 2012. A total of 247 patients with one- or two-level central lumbar spinal stenosis, stratified by the presence of DS, were randomized to decompression alone or decompression with fusion. The five-year Oswestry Disability Index (ODI) was the primary outcome. Secondary outcomes were the EuroQol five-dimension questionnaire (EQ-5D), visual analogue scales for back and leg pain, and patient-reported satisfaction, decreased pain, and increased walking distance. The reoperation rate was recorded.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 125 - 132
1 May 2024
Carender CN Perry KI Sierra RJ Trousdale RT Berry DJ Abdel MP

Aims

Uncemented implants are now commonly used at reimplantation of a two-stage revision total hip arthoplasty (THA) following periprosthetic joint infection (PJI). However, there is a paucity of data on the performance of the most commonly used uncemented femoral implants – modular fluted tapered (MFT) femoral components – in this setting. This study evaluated implant survival, radiological results, and clinical outcomes in a large cohort of reimplantation THAs using MFT components.

Methods

We identified 236 reimplantation THAs from a single tertiary care academic institution from September 2000 to September 2020. Two designs of MFT femoral components were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years (SD 11), mean BMI was 32 kg/m2 (SD 7), and 46% (n = 109) were female. Mean follow-up was seven years (SD 4). A competing risk model accounting for death was used.


Bone & Joint Open
Vol. 3, Issue 10 | Pages 832 - 840
24 Oct 2022
Pearson NA Tutton E Joeris A Gwilym SE Grant R Keene DJ Haywood KL

Aims

To describe outcome reporting variation and trends in non-pharmacological randomized clinical trials (RCTs) of distal tibia and/or ankle fractures.

Methods

Five electronic databases and three clinical trial registries were searched (January 2000 to February 2022). Trials including patients with distal tibia and/or ankle fractures without concomitant injuries were included. One reviewer conducted all searches, screened titles and abstracts, assessed eligibility, and completed data extraction; a random 10% subset were independently assessed and extracted by a second reviewer at each stage. All extracted outcomes were mapped to a modified version of the International Classification of Functioning, Disability and Health framework. The quality of outcome reporting (reproducibility) was assessed.


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1025 - 1031
1 Sep 2022
Thummala AR Xi Y Middleton E Kohli A Chhabra A Wells J

Aims

Pelvic tilt is believed to affect the symptomology of osteoarthritis (OA) of the hip by alterations in joint movement, dysplasia of the hip by modification of acetabular cover, and femoroacetabular impingement by influencing the impingement-free range of motion. While the apparent role of pelvic tilt in hip pathology has been reported, the exact effects of many forms of treatment on pelvic tilt are unknown. The primary aim of this study was to investigate the effects of surgery on pelvic tilt in these three groups of patients.

Methods

The demographic, radiological, and outcome data for all patients operated on by the senior author between October 2016 and January 2020 were identified from a prospective registry, and all those who underwent surgery with a primary diagnosis of OA, dysplasia, or femoroacetabular impingement were considered for inclusion. Pelvic tilt was assessed on anteroposterior (AP) standing radiographs using the pre- and postoperative pubic symphysis to sacroiliac joint (PS-SI) distance, and the outcomes were assessed with the Hip Outcome Score (HOS), International Hip Outcome Tool (iHOT-12), and Harris Hip Score (HHS).


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 43 - 43
1 Mar 2010
Egan C Cummins F O Connor P Kenny P
Full Access

Aim: It is widely accepted that surgical skills improve with experience. Part of this experience comes from operating on patients while honing new skills. Total hip arthroplasty is one such procedure. This paper examines outcomes in relation to the primary surgeon. Methodology: All patients who had an Exeter femoral component implanted and 2 years follow-up in the hospital joint register had their X-Ray, outcome scores and complications reviewed. Complications are routinely recorded as part of the joint register and hospital computer discharge system. Radiological outcome measures were taken as recommended by Johnston et al. Procedures were recorded as either performed by consultant surgeon or registrar supervised by consultant surgeon. Results: Post operative WOMAC scores at six months and 2 years were similar in both groups (Consultant 19.6, registrar 22.32 at 6 months) SF-36 figures were similar at six months (Consultant performed 78.56, consultant supervised 75.39). There was a difference in SF-36 at 2 years (72.77 vs 63.11) but this was not statistically significant. Average abduction angle was lower in consultant supervised than consultant performed procedure. (36.75 vs 47 deg) Barrack cement grading was similar in both groups. Consultant inserted stems were more likely to be in neutral position compared to consultant supervised stems (84% vs 56%). Conclusion: In both goups the quality of life indexes do show a difference in outcome which relates to the primary surgeon.. However decreased abduction angle may lead to decreased range of motion post operatively and should be addressed intraoperatively


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 50 - 50
1 Mar 2010
Ali A Boran S Leonard M Cogley D
Full Access

Introduction: Distal radius metaphyseal fractures in children are not uncommon, but when they occur proximal to the insertion of the pronator quadratus muscle, reduction and maintenance of reduction can be challenging. The deforming forces at the fracture site result in pronation and shortening of the distal fragment. Manual manipulation of this fracture often results in tearing of the dorsal periosteum and hence renders this fracture highly unstable. Aim: We present a novel easily reproducible mini-open surgical technique and functionally and radiologically evaluate a series of eleven patients who have undergone this technique. Materials and Methods: The surgical technique consists of a mini-open intrafocal image intensifier guided reduction technique with percutaneous k-wiring fixation. Five males and six females with an average age of 8.8 years (range 5 to 13 years), who sustained a pronator quadratus distal radius fracture and subsequently underwent this surgical technique from 2005 to 2007, were evaluated both radiologically in terms of radial length, radial tilt and volar tilt compared with the contralateral limb and functionally using the Mayo Modified wrist score and the patient related wrist evaluation questionnaire. Results: Patients were followed up for an average of 18 months (range 2–31 months). All patients achieved clinical and radiological union. No patient required remanipulation for loss of reduction. Radiological outcome measures similar to contralateral limb with good functional scores. No complications were noted. All patients returned to preoperative level of function. Conclusion: This minimally invasive technique has been shown to be technically easy, reliable and reproducible with excellent results and low risk of displacement compared to other techniques used to treat this potentially challenging fracture


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 99 - 99
1 Mar 2010
Egan C Cummins F O Connor P Kenny P
Full Access

Aim: It is widely accepted that surgical skills improve with experience. Part of this experience comes from operating on patients while honing new skills. Total hip arthroplasty is one such procedure. This paper examines outcomes in relation to the primary surgeon. Methodology: All patients who had an Exeter femoral component implanted and 2 years follow-up in the hospital joint register had their X-Ray, outcome scores and complications reviewed. Complications are routinely recorded as part of the joint register and hospital computer discharge system. Radiological outcome measures were taken as recommended by Johnston et al. Procedures were recorded as either performed by consultant surgeon or registrar supervised by consultant surgeon. Results: Post operative WOMAC scores at six months and 2 years were similar in both groups (Consultant 19.6, registrar 22.32 at 6 months) SF-36 figures were similar at six months (Consultant performed 78.56, consultant supervised 75.39). There was a difference in SF-36 at 2 years (72.77 vs 63.11) but this was not statistically significant. Average abduction angle was lower in consultant supervised than consultant performed procedure. (36.75 vs 47 deg) Barrack cement grading was similar in both groups. Consultant inserted stems were more likely to be in neutral position compared to consultant supervised stems (84% vs 56%). Conclusion: In both goups the quality of life indexes do show a difference in outcome which relates to the primary surgeon. However decreased abduction angle may lead to decreased range of motion post operatively and should be addressed intraoperatively


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1343 - 1351
1 Dec 2022
Karlsson T Försth P Skorpil M Pazarlis K Öhagen P Michaëlsson K Sandén B

Aims

The aims of this study were first, to determine if adding fusion to a decompression of the lumbar spine for spinal stenosis decreases the rate of radiological restenosis and/or proximal adjacent level stenosis two years after surgery, and second, to evaluate the change in vertebral slip two years after surgery with and without fusion.

Methods

The Swedish Spinal Stenosis Study (SSSS) was conducted between 2006 and 2012 at five public and two private hospitals. Six centres participated in this two-year MRI follow-up. We randomized 222 patients with central lumbar spinal stenosis at one or two adjacent levels into two groups, decompression alone and decompression with fusion. The presence or absence of a preoperative spondylolisthesis was noted. A new stenosis on two-year MRI was used as the primary outcome, defined as a dural sac cross-sectional area ≤ 75 mm2 at the operated level (restenosis) and/or at the level above (proximal adjacent level stenosis).


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 252 - 253
1 Jul 2008
TRICLOT P
Full Access

Purpose of the study: The limitations of conventional polyethylene are well known (osteolysis). New bearing surfaces have been proposed for hip arthroplasty including new-generation polyethylene products. Material and methods: We compared four bearings including one metal-on-metal and one ceramic-on-ceramic bearing with results not available for analysis at this 4 years 8 month follow-up. The comparative randomized study included 102 first intention total hip arthroplasties comparing a single variable: the bearing. Common elements were: metal-back press-fit cup (Fitmore) and cemented anatomic stem (Emeraude). Variable elements were: alpha Sulène insert + 28 metal head (n=53) versus alpha Dursul insert + 28 metal head (n=49). Clinical outcome was assessed with the Postel-Merle-d’Aubigné score and the Harris score. Radiological outcome was assessed with: wear (EBRA, semiautomatic linear radiographic penetration), cup migration according to EBRA, and radiographic changes in zone 7. Results: After checking the validity of the files studied, clinical outcome was strictly the same for the two series: wear Sulène polyethylene 0.21 mm; Durasul polyethylene 0.1 mm. Cup migration was: Sulène polyethylene 0.13 mm; Durasul polyethylene 0.08 mm. Modifications of zone 7 were: Sulène polyethylene 17.8%; Durasul polyethylene 6.6%. Conclusion: With 4 years 8 months follow-up, several elements are in favor of the new-generation polyethylene inserts, confirming theoretical results with mathematical models. This length of follow-up is insufficient to draw formal conclusions concerning in vivo aging


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 64 - 64
1 Mar 2012
Gabr AK Withers DP Santini AS
Full Access

Introduction. The aim of this study was to compare the outcome between the first and second knee replacement in patients undergoing staged bilateral total knee arthroplasty. Methods. A prospective database of outcomes of knee replacements performed at Broadgreen Hospital was commenced in 2003. Data is collected pre operatively, 3 and 12 months post operatively and every two years thereafter. We identified 64 patients (26 male, 38 female) who had bilateral knee replacements and had at least one year post operative outcome studies. Data on pain scores, walking ability (score 1-6), use of walking aids (score 1-6), range of movement, instability, muscle strength, WOMAC scores, SF-12 scores, the Knee Society Radiological Score and length of hospital stay were identified. We compared data between the first and second knee operation. Results. Groups remained statistically comparable between the 1st and 2nd operation. Average score for post op walking ability was 4.83 (2. nd. knee) vs 4.51 (1. st. knee) (p=0.03). Average score for post op walking aid requirement was 5.73 (2. nd. knee) vs 5.46 (1. st. knee) (p=0.01). Patient's post op SF-12 scores were 54.26 (2. nd. knee) vs 52.45 (1. st. knee) (p=0.04). Average hospital stay was 4.73 (2. nd. Knee) vs 6.06 (1. st. knee) (p=0.05). All other data comparison was statistically insignificant. Conclusion. Patients have reduced hospital stay and continue to improve after the second procedure with regards to walking ability, use of walking aids and psychological well being. This may be because having the worst knee replaced first means improved walking ability and decreased need for walking aids after the second operation. Also patients have already experienced one knee replacement and therefore are less apprehensive and more familiar with the post operative physiotherapy and rehabilitation programme


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 148 - 148
1 Mar 2012
Morgan B Livingstone J MacFadyen I Jackson M Atkins R
Full Access

Introduction. The optimal management of intra-articular tibial plateau fractures with metaphyseal-diaphyseal dissociation remains challenging and controversial. We report results using the technique of limited open reduction with external fixation using a fine wire circular frame. Method. Between 1994 –2006, 83 eligible patients were identified. Case notes were reviewed; X-Rays and CT scans were examined and used to rank-order the severity of injury. ‘Musculoskeletal Functional Assessment’ (MFA) and ‘Knee Outcome Survey’ (KOS) questionnaires were completed and axial alignment X-Rays were taken to assess functional and radiological outcome. Results. 47 patients were available for follow-up at mean 57 months post injury. All fractures had united. There were 3 cases (6.39%) of pin site infection that necessitated debridement of superficial soft tissues. There were no cases of deep infection. Functional outcome. The mean MFA score was 24.7 points (range, 2 to 68 points). Leisure & recreation (51.06), mobility (37.02) and emotional score (33.22) were most affected. The mean KOS was 73.11 (range, 18.75 to 96.25). When compared to control population, our patient cohort still have significant persistent levels of disability. No correlation was found between severity of injury, nor any patient demographic factors and functional outcome. 26 patients (85.1%) had returned to employment, though 29.8% had either been forced to change occupation or were limited in their original occupation by their injury. Radiological outcome. Knee subluxation was found to have a significant association with poorer MFA (-0.323 p = 0.028) and KOS scores (0.304 p = 0.04). No other radiological measures correlated with functional outcome. Conclusion. Treatment of these severe injuries by circular frame and limited internal fixation is a safe and effective operative option. It offers early mobilisation and movement of the knee, with a low complication rate and functional outcome equivalent to other treatment modalities


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 895 - 904
1 Aug 2023
Smith TO Dainty J Loveday DT Toms A Goldberg AJ Watts L Pennington MW Dawson J van der Meulen J MacGregor AJ

Aims

The aim of this study was to capture 12-month outcomes from a representative multicentre cohort of patients undergoing total ankle arthroplasty (TAA), describe the pattern of patient-reported outcome measures (PROMs) at 12 months, and identify predictors of these outcome measures.

Methods

Patients listed for a primary TAA at 19 NHS hospitals between February 2016 and October 2017 were eligible. PROMs data were collected preoperatively and at six and 12 months including: Manchester-Oxford Foot and Ankle Questionnaire (MOXFQ (foot and ankle)) and the EuroQol five-dimension five-level questionnaire (EQ-5D-5L). Radiological pre- and postoperative data included Kellgren-Lawrence score and implant position measurement. This was supplemented by data from the National Joint Registry through record linkage to determine: American Society of Anesthesiologists (ASA) grade at index procedure; indication for surgery, index ankle previous fracture; tibial hind foot alignment; additional surgery at the time of TAA; and implant type. Multivariate regression models assessed outcomes, and the relationship between MOXFQ and EQ-5D-5L outcomes, with patient characteristics.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1168 - 1176
1 Nov 2023
Yüksel Y Koster LA Kaptein BL Nelissen RGHH den Hollander P

Aims

Conflicting clinical results are reported for the ATTUNE Total Knee Arthroplasty (TKA). This randomized controlled trial (RCT) evaluated five-year follow-up results comparing cemented ATTUNE and PFC-Sigma cruciate retaining TKAs, analyzing component migration as measured by radiostereometric analysis (RSA), clinical outcomes, patient-reported outcome measures (PROMs), and radiological outcomes.

Methods

A total of 74 primary TKAs were included in this single-blind RCT. RSA examinations were performed, and PROMs and clinical outcomes were collected immediate postoperatively, and at three, six, 12, 24, and 60 months’ follow-up. Radiolucent lines (RLLs) were measured in standard anteroposterior radiographs at six weeks, and 12 and 60 months postoperatively.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 242 - 248
1 Feb 2022
Smolle MA Fischerauer SF Zötsch S Kiegerl AV Sadoghi P Gruber G Leithner A Bernhardt GA

Aims

The aim of this prospective study was to assess the long-term clinical, radiological, functional, and quality of life (QoL)-related outcome of patients treated with the synthetic Ligament Advanced Reinforcement System (LARS) device for anterior cruciate ligament (ACL) rupture.

Methods

A total of 41 patients who underwent ACL reconstruction with the LARS device (mean age 39.8 years (SD 12.1 ); 32% females (n = 13)) were prospectively included between August 2001 and March 2005. MRI scans and radiographs were performed at a median follow-up of 2.0 years (interquartile range (IQR) 1.3 to 3.0; n = 40) and 12.8 years (IQR 12.1 to 13.8; n = 22). Functional and QoL-related outcome was assessed in 29 patients at a median follow-up of 12.8 years (IQR 12.0 to 14.0) and clinically reconfirmed at latest median follow-up of 16.5 years (IQR 15.5 to 17.9). International Knee Documentation Committee (IKDC) and Tegner scores were obtained pre- and postoperatively, and Lysholm score postoperatively only. At latest follow-up, range of motion, knee stability tests, 36-Item Short Form Health Survey (SF-36), and IKDC scores were ascertained. Complications and reoperations during follow-up were documented.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 324 - 335
1 Apr 2024
Fontalis A Kayani B Plastow R Giebaly DE Tahmassebi J Haddad IC Chambers A Mancino F Konan S Haddad FS

Aims

Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA.

Methods

This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 180 - 180
1 Feb 2004
Papas M Kaisidis A Megas P Zouboulis P Lambiris E
Full Access

Aim:Evaluate the results of primary cemented/cementless THA for the treatment of displaced femoral neck fractures. Material-Method:121 pts with femoral neck fractures underwent THA 2.1 days on average after their admission.The mean follow up period 4.1 y.112 pts had Garden III-IV fractures,9 pts had Garden II fractures.A cementless THA was applied in 75 pts (Group A,average age 61.4 y),46 pts were treated with cemented THA (Group B,72.4 y).Last follow up evaluation with Harris Hip Score (HHS) and radiological assessment with the Engh/Wixon scores was available in 92 pts.In 25 elderly pts a cementless THA was applied due to established impairment of their cardiopulmonary status. Results:The mean HHS was 82,3.Radiological score for the cementless THA:+5,8 for the cup and +6,4 for the stem according to Engh scale (satisfactory integration for the prosthesis Perfecta,Synergy) and a 74,8% liability of integration according to Wixon scale (Spotorno).Complications:Early dislocation 3,loosening 5,heterotopic ossification 8,periprosthetic fracture 1,femoral nerve paresis 1,wound infection 1.No systematic complications were noted in the elderly patients with cardiopulmonary disorders,possible due to selection of a cementless THA. Conclusions:THA (cemented/cementless) for the treatment of displaced femoral neck fractures give very good midterm results.Cementless THA is probably the choice of treatment in elderly pts with cardiopulmonary disorders