header advert
Results 1 - 72 of 72
Results per page:

Aims. The aim of this study was to compare the mid-term patient-reported outcome, bone remodelling, and migration of a short stem (Collum Femoris Preserving; CFP) with a conventional uncemented stem (Corail). Methods. Of 81 patients who were initially enrolled, 71 were available at five years’ follow-up. The outcomes at two years have previously been reported. The primary outcome measure was the clinical result assessed using the Oxford Hip Score (OHS). Secondary outcomes were the migration of the stem, measured using radiostereometric analysis (RSA), change of bone mineral density (BMD) around the stem, the development of radiolucent lines, and additional patient-reported outcome measures (PROMs). Results. There were no statistically significant differences between the groups regarding PROMs (median OHS (CFP 45 (interquartile range (IQR) 35 to 48); Corail 45 (IQR 40 to 48); p = 0.568). RSA showed stable stems in both groups, with little or no further subsidence between two and five years. Resorption of the femoral neck was evident in nine patients in the CFP group and in none of the 15 Corail stems with a collar that could be studied. Dual X-ray absorbiometry showed a significantly higher loss of BMD in the proximal Gruen zones in the CFP group (mean changes in BMD: Gruen zone 1, CFP -9.5 (95% confidence interval (CI) -14.8 to -4.2), Corail 1.0 (95% CI 3.4 to 5.4); Gruen zone 7, CFP -23.0 (95% CI -29.4 to -16.6), Corail -7.2 (95% CI -15.9 to 1.4). Two CFP stems were revised before two years’ follow-up due to loosening, and one Corail stem was revised after two years due to chronic infection. Conclusion. The CFP stem has a similar clinical outcome and subsidence pattern when compared with the Corail stem. More pronounced proximal stress-shielding was seen with the CFP stem, suggesting diaphyseal fixation, and questioning its femoral neck-sparing properties in the long term. Cite this article: Bone Joint J 2022;104-B(5):581–588


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 395 - 395
1 Jul 2010
Bali N Leggetter P Sidaginamale R Pynsent P Dunlop D Pearson A
Full Access

Introduction: The Corail stem is a well proven femoral implant used for the past 22 years. It is the most common uncemented femoral stem used for total hip replacements in the UK. The stem was modified in 2004 with an increased neck taper to allow for an increased range of bearings and modular heads. This study reviews a series of primary total hip replacements using this recently modified Corail stem to assess if this implant is still performing to acceptable standards. Method: A prospective patient database collated by 2 arthroplasty surgeons recorded data at the time of operation and subsequent follow up. All intra-operative and post-operative complications were recorded. Pre and postoperative oxford hip scores were analysed. Results: 751 cases were reviewed. The average age was 63 with females accounting for 69%. The pinnacle cup was used in 83% of cases, with a polyethylene bearing in 48%. Survival of the stem at 3 years was 99.9% (1 periprosthetic fracture following a fall), the cup 99.6%, with overall survival of 99.5%. The most common intra operative complication was calcar fracture occurring in 0.9%. Dislocation occurred in 0.5%, subsidence in 0.3%, deep infection in 0.1% and leg length discrepancy requiring shoe raise in 0.1%. Average 3 year oxford hip score was 12. Discussion: 3 year survival of both the femoral stem and the total hip replacement are above the quoted rates in the National Joint Registry’s 4th annual report for corail and uncemented stems (98.8% and 98.1% respectively), and also exceeds that of cemented stems (99.1%). The same report quotes similar rates of calcar fractures (0.8%), although we recorded no other perioperative complications. We conclude the new generation of Corail stem has excellent 3 year performance


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 301 - 301
1 Nov 2002
Khatib Y Schwartz O Mendes D Said M
Full Access

Purpose: The purpose of this study is to present our imaging results of Corail stem implant after 11 years of follow-up. Material and Methods: 31 patients that underwent total hip arthroplasty between 1990–1996 in which Corail stem was implanted were included in this study. The imaging parameters that were collected from patient X-rays were: radiolucent line, osteolysis, subsidence, cortical hypertrophy, cortical thinning, undersizing, distal pod, rounded calcar, cupping and sagging. Results: Our of 31 patients, 21 were man and 10 were women, the mean age was 60.5 years (range 32–77y), 6 were bilateral, 3 patients had trochanteric osteotomy before surgery. The mean follow-up period was 8.2 years (range 5–11y). No sign of loosening were observed in any patient, 23 stems were implanted in neutral position, 2 stems in valgus and 6 in varus position. In 15 patients stem was undersized. In 23 patients distal pod was observed, 19 patients had trochanteric osteopenia, in 10 patients cupping was noticed and in 6 patients cortical thinning was observed. Five patients showed proximal osteopenia and in 5 patients sagging of few millimeters was noticed during the first years after surgery. No radiolucent line, osteolysis, subsidence and cortical hypertrophy were observed up to 11 years follow-up. Discussion: No signs of loosening were observed in all stems after 11 years of follow-up. Conclusion: In our opinion Corail stem for THA is a very reliable implant


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 32 - 32
1 Jun 2016
Sharma V Shamoon R Maheson M Jones SA
Full Access

Introduction. The Corail stem is a fully HA coated tapered implant that has demonstrated long-term success. On the NJR it has become one of the most commonly used implants in the UK. The aim of our study was to document our experience of the revision of this implant together highlighting some important technical considerations. Patients/Materials & Methods. A retrospective review of a consecutive case series of revision procedures where the Corail stem was extracted. We considered time since implantation, collared or uncollared design, indication for revision, Paprosky classification of femoral deficiency, endo-femoral reconstruction or extended approach/osteotomy, subsequent reconstruction either further primary type implant (cemented or cementless) or revision femoral implant. Results. 49 patients required extraction of Corial Stem as part of revision THA. Mean time to extraction 5.2 years (range 1.1 to 10.5 years). Indication for revision in 27 cases ARMD, 7 aseptic loosening, 7 PJI, 6 Peri-prosthetic fractures and 2 instability. The only cases that utilised an extended approach were those performed for peri-prosthetic fracture (5 B2 & 1 Type C fractures) all of which were reconstructed with a Modular Taper Fluted Stem. Of the remaining 43 cases revised for other reasons femoral bone stock was Paprosky Grade 2 in 21 cases, grade 3A in 22 cases. Stems were extracted with implant specific extraction device via endo-feomral route and subsequent reconstruction utilised a primary type femoral implant in 34% of cases. Discussion. All stems, apart from those revised for peri-prosthetic fracture were reconstructed via endo-femoral route. Safe implant extraction is key in this approach and the success of this method in our series emphasizes the major importance of the implant specific extraction instrumentation. Conclusion. As a result of safe implant extraction over 1/3. rd. of patients were able to have a primary implant inserted at the time of revision surgery


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 35 - 35
2 May 2024
Robinson M Wong ML Cassidy R Bryce L Lamb J Diamond O Beverland D
Full Access

The significance of periprosthetic fractures about a total hip arthroplasty (THA) is becoming increasingly important. Recent studies have demonstrated post-operative periprosthetic fracture rates are higher amongst cemented polished taper slip (PTS) stem designs compared to collared cementless (CC) designs.

However, in the National Joint Registry, the rate of intra-operative periprosthetic femoral fractures (IOPFF) with cementless implant systems remains higher (0.87% vs 0.42%. p <0.001) potentially leading to more post-operative complications.

This study identifies the incidence of IOPFF, the fracture subtype and compares functional outcomes and revision rates of CC femoral implants with an IOPFF to CC stems and PTS stems without a fracture.

5376 consecutive CC stem THA, carried out through a posterior approach were reviewed for IOPFF. Each fracture was subdivided into calcar fracture, greater trochanter (GT) fracture or shaft fracture.

1:1:1 matched analysis was carried out to compare Oxford scores at one year. Matching criteria included; sex (exact), age (± 1 year), American Society of Anaesthesiologists (ASA) grade (exact), and date of surgery (± 6 months).

Electronic records were used to review revision rates.

Following review of the CC stems, 44 (0.8%) were identified as having an IOPFF. Of these 30 (0.6%) were calcar fractures, 11 (0.2%) GT fractures and 3 (0.06%) were shaft fractures. There were no shaft penetrations.

Overall, no significant difference in Oxford scores at one year were observed when comparing the CC IOPFF, CC non-IOPFF and PTS groups.

There were no CC stems revised for any reason with either a calcar fracture or trochanteric fracture within the period of 8 years follow-up.

IOPFF do occur more frequently in cementless systems than cemented. The majority are calcar and GT fractures. These fractures, when identified and managed intra-operatively, do not have worse functional outcomes or revision rates compared to matched non-IOPFF cases.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 19 - 19
1 Aug 2018
van der Jagt DR Brekon A Mokete L Pietrzak J Nortje M Schepers A
Full Access

A longitudinal study was done assessing the latest radiographs available in a series of collarless Corail uncemented stems which have reported survival rates of 95% at 20 years. Parameters scored included the degree of “Ghosting” or delamination, the Gruen, the stem fit in the femoral canal and the degree of calcar resorption. Patient and implant demographics were noted. At 3 years the loosening rate was 23% reaching 64% at 6 years after the index procedure. It was present in all age groups, with a peak in the 24 to 49 year age group. Males and females had the same occurrence. When it was present this was always in zone 1. It was present in 6% of patients in zone 7, but then always associated with zone 1 changes. High and standard off-set stems had the same loosening rates. The looser fit of the stem the higher the incidence of loosening. There was no correlation to the type of bearing surface or the degree of calcar resorption. Those patients with a BMI of 25 – 35 had lower loosening rates compared to those with higher or lower BMI's. We postulate that cancellous bone on-growth onto the hydroxyapatite coating associated with loading flexural micro-motion leads to hydroxyapatite being pulled off the smooth stem substrate in zone 1. Progressive delamination of the hydroxyapatite then occurs. The triple-tapered design though imparts continued stability. We report high loosening rates in the Corail stem and suggest a mechanism for its development


Bone & Joint 360
Vol. 11, Issue 2 | Pages 52 - 54
1 Apr 2022
Evans JT Evans JP Whitehouse MR


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 14 - 14
1 Jan 2016
Grosser D Mercer G Wilson C Nilsson K Krishnan J
Full Access

Background

Safety and efficacy of novel prostheses relies on the determination of early implant migration and subsequent risk of loosening. Radiostereometric Analysis (RSA) has been used to evaluate the clinical failure risks of femoral stems by reporting distal migration, a measure of stem subsidence, when examining early migration characteristics. The migratory patterns of femoral stems, 24 months postoperatively, have provided a surrogate outcome measure to determine implant stabilisation and predict long-term performance and survivorship. RSA assessed femoral stem migration and provided comparison of the early migration characteristics with published data of a clinically established counterpart.

Methods

Twenty five patients undergoing primary total hip arthroplasty were implanted with a hydroxyapatite-coated femoral stem. The median age was 65 years (range, 43–75 years). During surgery tantalum markers were attached onto the distal tip and shoulder of the stem. Eight tantalum markers were inserted into the femur, four placed in each of the greater and lesser trochanter. RSA examinations were performed postoperatively at 4 to 5 days, 6, 12 and 24 months. Eleven patients who had complete RSA follow-up as well as the valid data from five patients were analysed to determine the movement of the femoral stem relative to the femur and were compared to the published data of a clinically established counterpart.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 28 - 28
10 Feb 2023
Faveere A Milne L Holder C Graves S
Full Access

Increasing femoral offset in total hip replacement (THR) has several benefits including improved hip abductor strength and enhanced range of motion. Biomechanical studies have suggested that this may negatively impact on stem stability. However, it is unclear whether this has a clinical impact. Using data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), the aim of this study was to determine the impact of stem offset and stem size for the three most common cementless THR prostheses revised for aseptic loosening. The study period was September 1999 to December 2020. The study population included all primary procedures for osteoarthritis with a cementless THR using the Corail, Quadra-H and Polarstem. Procedures were divided into small and large stem sizes and by standard and high stem offset for each stem system. Hazard ratios (HR) from Cox proportional hazards models, adjusting for age and gender, were performed to compare revision for aseptic loosening for offset and stem size for each of the three femoral stems. There were 55,194 Corail stems, 13,642 Quadra-H stem, and 13,736 Polarstem prostheses included in this study. For the Corail stem, offset had an impact only when small stems were used (sizes 8-11). Revision for aseptic loosening was increased for the high offset stem (HR=1.90;95% CI 1.53–2.37;p<0.001). There was also a higher revision risk for aseptic loosening for high offset small size Quadra-H stems (sizes 0-3). Similar to the Corail stem, offset did not impact on the revision risk for larger stems (Corail sizes 12-20, Quadra-H sizes 4-7). The Polarstem did not show any difference in aseptic loosening revision risk when high and standard offset stems were compared, and this was irrespective of stem size. High offset may be associated with increased revision for aseptic loosening, but this is both stem size and prosthesis specific


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 19 - 26
1 Jan 2022
Sevaldsen K Schnell Husby O Lian ØB Farran KM Schnell Husby V

Aims. Highly polished stems with force-closed design have shown satisfactory clinical results despite being related to relatively high early migration. It has been suggested that the minimal thickness of cement mantles surrounding the femoral stem should be 2 mm to 4 mm to avoid aseptic loosening. The line-to-line cementing technique of the femoral stem, designed to achieve stem press-fit, challenges this opinion. We compared the migration of a highly polished stem with force-closed design by standard and line-to-line cementing to investigate whether differences in early migration of the stems occur in a clinical study. Methods. In this single-blind, randomized controlled, clinical radiostereometric analysis (RSA) study, the migration pattern of the cemented Corail hip stem was compared between line-to-line and standard cementing in 48 arthroplasties. The primary outcome measure was femoral stem migration in terms of rotation and translation around and along with the X-, Y-, and Z- axes measured using model-based RSA at three, 12, and 24 months. A linear mixed-effects model was used for statistical analysis. Results. Results from mixed model analyses revealed a lower mean retroversion for line-to-line (0.72° (95% confidence interval (CI) 0.38° to 1.07°; p < 0.001), but no significant differences in subsidence between the techniques (-0.15 mm (95% CI -0.53 to 0.227; p = 0.429) at 24 months. Radiolucent lines measuring < 2 mm wide were found in three and five arthroplasties cemented by the standard and line-to-line method, respectively. Conclusion. The cemented Corail stem with a force-closed design seems to settle earlier and better with the line-to-line cementing method, although for subsidence the difference was not significant. However, the lower rate of migration into retroversion may reduce the wear and cement deformation, contributing to good long-term fixation and implant survival. Cite this article: Bone Joint J 2022;104-B(1):19–26


We evaluated an anatomical uncemented stem, SP-CL, (Static Physiologicus – CementLess) designed to facilitate insertion and to avoid stress concentration at solitary contact points in a randomized controlled trial, with use of the Corail stem as control. The SPÅ-Cl stem has been on the market since 2014 but is still not well documented. 79 patients (80 hips) were primarily recruited and 71 patients (72 hips, 36 SP-CL, 36 Corail) attended the last follow up at 2 years. The clinical evaluation included several types of PROMs with Oxford Hip Score (OHS) as primary outcome. In addition, repeated measurements of stem migration, changes in bone mineral density and development of radiolucencies were studied with RSA, DXA and conventional radiography. At two years the Oxford Hip Score did not differ between the SP-CL and Corail stem (estimated mean difference: −0.70 (95% CI: −4.28 – 2.89). In both groups Oxford hip score had almost doubled at 3 months, continued to increase up to 6 months and was about equal at 2 years (SP-CL; median 46 (17–48), Corail; median 47 (19–48)). At 2 years the SP-CL stems showed a median distal migration of −0.23 (−5.2 – 0.1) and the Corail stems of − 0.11 (−4.4 – 0.4). The SP-CL stems showed slightly more loss of bone mineral density in Gruen region 7 (p = 0.003). We found no difference in clinical results with use of either of the two stems. Bone mineral density loss tended to be higher with use of the SP-CL stem and the early subsidence tended to be more pronounced, which turned out to be compatible with about the same stem stability reached between 1 and 2 years. As a next step we think that the SP-CL stem should be studied in a multi-center setting, before accepted for general use


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1435 - 1441
1 Nov 2017
Buttaro MA Oñativia JI Slullitel PA Andreoli M Comba F Zanotti G Piccaluga F

Aims. The Corail stem has good long-term results. After four years of using this stem, we have detected a small group of patients who have presented with symptomatic metaphyseal debonding. The aim of this study was to quantify the incidence of this complication, to delineate the characteristics of patients presenting with this complication and to compare these patients with asymptomatic controls to determine any important predisposing factors. Patients and Methods. Of 855 Corail collarless cementless stems implanted for osteoarthritis, 18 presented with symptomatic metaphyseal debonding. A control group of 74 randomly selected patients was assembled. Clinical and radiological parameters were measured and a logistic regression model was created to evaluate factors associated with metaphyseal debonding. Results. The prevalence of this complication was 2.1% in our series. In the multivariable model, the presence of a Dorr B-type proximal femur was associated with metaphyseal debonding (odds ratio (OR) 10.73, 95% confidence interval (CI) 2.31 to 49.97, p = 0.002), as was a body mass index > 25 kg/m. 2. (OR 6.85, 95% CI 1.06 to 44.28, p = 0.04). Smaller stems and the use of a polyethylene acetabular liner appeared to be protective when compared with metal and ceramic setting hard-on-hard bearings. Conclusion. We have described an uncommon but important mode of failure of the Corail stem. Surgeons should be aware of this phenomenon; overweight patients with Dorr B-type femurs and in whom hard bearings are used appear to be particularly at risk. Cite this article: Bone Joint J 2017;99-B:1435–41


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 44 - 44
1 Dec 2022
Turgeon T Bohm E Gascoyne T Hedden D Burnell C
Full Access

This study used model-based radiostereometric analysis (MBRSA) to compare migration of a recently introduced cementless hip stem to an established hip stem of similar design. Novel design features of the newer hip stem included a greater thickness of hydroxyapatite coating and a blended compaction extraction femoral broach. Fifty-seven patients requiring primary total hip arthroplasty (THA) were enrolled at a single centre. Patients were randomized to receive either an Avenir collarless stem and Trilogy IT cup (ZimmerBiomet) or a Corail collarless stem and Pinnacle cup (DePuy Synthes) via a posterior or lateral approach. Both stems are broach-only femoral bone preparation. RSA beads (Halifax Biomedical) were inserted into the proximal femur during surgery. Patients underwent supine RSA imaging a 6 weeks (baseline), 6, 12, and 24 months following surgery. The primary study outcome was total subsidence of the hip stem from baseline to 24 months as well as progression of subsidence between 12 and 24 months. These values were compared against published migration thresholds for well-performing hip stems (0.5mm). The detection limit, or precision, of MBRSA was calculated based on duplicate examinations taken at baseline. Patient reported outcome measures were collected throughout the study and included the Oxford-12 Hip Score (OHS), EuroQoL EQ-5D-5L, Hip Osteoarthritis Score (HOOS) as well as visual analogue scales (VAS) for thigh pain and satisfaction. Analysis comprised of paired and unpaired t-tests with significance set at p≤0.05. Forty-eight patients (30 males) were included for analysis; 7 patients received a non-study hip stem intra-operatively, 1 patient suffered a traumatic dislocation within three weeks of surgery, and 1 patient died within 12 months post-surgery. RSA data was obtained for 45 patients as three patients did not receive RSA beads intra-operatively. Our patient cohort had a mean age of 65.9 years (±;7.2) at the time of surgery and body mass index of 30.5 kg/m2 (±;5.2). No statistical difference in total stem migration was found between the Avenir and Corail stems at 12 months (p=0.045, 95%CI: −0.046 to 0.088) and 24 months (p=0.936, 95% CI: −0.098 to 0.090). Progression of subsidence from 12-24 months was 0.011mm and 0.034mm for the Avenir and Corail groups which were not statistically different (p=0.163, 95%CI: −0.100 to 0.008) between groups and significantly less than the 0.5mm threshold (pNo statistically significant differences existed between study groups for any pre-operative function scores (p>0.05). All patients showed significant functional improvement from pre- to post-surgery and no outcome measures were different between study groups with exception of EQ-5D-5L health visual analogue scale at 12 months which showed marginally superior (p=0.036) scores in the Avenir group. This study was not powered to detect differences in clinical outcomes. This study has demonstrated no statistical difference in subsidence or patient-reported outcomes between the Corail hip stem and the more recently introduced Avenir hip stem. This result is predictable as both stems are of a triple-tapered design, are coated with hydroxyapatite, and utilize a broach-only bone preparation technique. Both stem designs demonstrate migration below 0.5mm suggesting both are low-risk for aseptic loosening in the long-term


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 13 - 13
23 Jun 2023
Furnes O Lygre SHL Hallan G Fenstad AM
Full Access

The Norwegian Arthroplasty Register (NAR) started collecting data on total hip arthroplasty (THA) in 1987. Very long-term results of implants for THA are scarce. We aimed to show long-term results for the three most used femoral stems, operated from 1987. We included the uncemented Corail femoral stem (n=66,309) and the cemented Exeter stem (n=35,050) both of which are currently in frequent use. In addition, we included the Charnley stem (n=32,578, in use until 2014). To ensure comparable conditions, stems fixated with low viscosity cement and stems revised due to infections were excluded. Differences in risk of revision (all reasons and stem revisions) were assessed with Kaplan-Meier and Cox regression analyses with adjustment for possible confounding from age, sex and diagnosis (OA, other). Stem revision was defined as a revision caused by loosening of the stem, dislocation, osteolysis in the femur, or periprosthetic femur fracture, and in which the femoral component was removed or exchanged. The median and max follow-up for Corail, Exeter and Charnley were 6.3 (33.1), 8.0 (34.2) and 13.1 (34.3) respectively. Thirty years survival estimates for Corail, Exeter and Charnley stems were 88.6% (CI:85.8–90.9%), 86.7% (83.7–89.2%) and 87.1% (85.4–88.5%) respectively with stem revision as endpoint, and 56.1% (CI:53.1–59.1%), 73.3% (70.5–76.1%) and 80.2% (78.4–82.0%) with all THA revisions as endpoint. Compared to the Corail, the Exeter (HRR=1.3, CI:1.2–1.4) and the Charnley (HRR=1.9, CI:1.7–2.1) had a significant higher risk of stem revision. Women 75 years and older had better results with the cemented stems. Analyses accounting for competing risk from other causes of revision did not alter the findings. The uncemented Corail stem performed well in terms of stem revisions for stem-related revision causes compared to two frequently used cemented stems with very long follow-up. The differences between the three stems were small


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1559 - 1564
1 Dec 2018
McConnell JS Saunders PRJ Young SK

Aims. Cementless femoral stems must be correctly sized and well-seated to obtain satisfactory biological fixation. The change in sound that occurs during impaction of the femoral broach is said to indicate good fit, but this has not been widely studied. We set out to find whether the presence or absence of these sound changes could predict correct sizing. Patients and Methods. We recorded the sound generated during femoral broaching for 105 cementless total hip arthroplasties using the Corail stem. Four cases were excluded, leaving 101 recordings for analysis. There were 36 male patients and 65 female patients, with a mean age of 69.9 years (. sd. 12.3) and median body mass index (BMI) of 29 kg/m. 2. (interquartile range (IQR) 26 to 32). The recordings were analyzed to identify the frequencies of the sounds produced during impaction of the femoral broach. Results. The emergence of a low-frequency band of sound in the 1 kHz range, during the final femoral broaching, was a strong predictor of a well-sized implant stem. The frequency was related to femoral length, supporting our hypothesis that the sound arose from the bone itself. Conclusion. The low-frequency sound generated during femoral broaching can be monitored spectrographically, its frequency can be predicted from femoral length, and it is a good predictor of appropriate stem sizing


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 50 - 50
1 Mar 2006
Hallan G Havelin L Furnes O
Full Access

Materials and methods: Based on data from the Norwegian Arthroplasty Register, we reviewed the results of uncemented femoral stems in Norway in the period 1987 to 1. April 2002. We compared these results to the results of the cemented Charnley monoblock stem, which still is the most commonly used femoral stem in Norway. Only prostheses used in more than one hundred hips were included. Based on these criteria, we identified a total of 7 856 primary total hip prostheses in fifteen different uncemented stems. With the Kaplan-Meier method, the survival of the primary prostheses were calculated and compared with each other and with the Charnley stem. The endpoint was revision in which the whole prostheses or the stem alone was removed or exchanged. The Cox regression analysis was used to adjust for differences in age, gender, diagnosis, former operations and profylactic antibiotics. Separate analyses for patients younger than 60 years and for stems with follow-up less than ten years were done. Reasons for revision in the uncemented Corail stem and the cemented Charnley stem was analysed. Results: The Corail stem, wich is the most commonly used uncemented stem in Norway (n=3590), had excellent long term results. 10 years survival in patients younger than 60 years was for the Corail 97,5% and for the Charnley 90,2% (p=0,001). Reasons for revision of the Corail were in most cases pain and repeated dislocations. Aseptic loosening was the dominant cause of failure of the Charnley stem. Several uncemented stems have results which are as good as or superior to the Charnley. The Femora, the Biofit, the Parhofer and the Harris Galante stems all had inferior results. Many uncemented stems with less than 10-years of follow-up have excellent 5 years survival. The 10 years survival of uncemented total hip arthroplasties, however was inferior to the all-cemented Charnley. Cup revisions due to aseptic loosening, and wear and/or osteolysis were the reasons for this. Discussion: The Corail stem has excellent long term results. Several newer stems have promising short- and medium term results. Due to inferior results of unce-mented cups, however, most Norwegian orthopaedic surgeons use cemented primary hip replacements


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 741 - 748
1 Jun 2015
Bonnin MP Neto CC Aitsiselmi T Murphy CG Bossard N Roche S

The aim of this study was to investigate the relationship between the geometry of the proximal femur and the incidence of intra-operative fracture during uncemented total hip arthroplasty (THA). We studied the pre-operative CT scans of 100 patients undergoing THA with an uncemented femoral component. We measured the anteroposterior and mediolateral dimensions at the level of division of the femoral neck to calculate the aspect ratio of the femur. Wide variations in the shape of the femur were observed, from round, to very narrow elliptic. The femurs of women were narrower than those of men (p < 0.0001) and small femurs were also narrower than large ones. Patients with an intra-operative fracture of the calcar had smaller and narrower femurs than those without a fracture (p < 0.05) and the implanted Corail stems were smaller in those with a fracture (mean size 9 vs 12, p < 0.0001). The variability of the shape of the femoral neck at the level of division contributes to the understanding of the causation of intra-operative fractures in uncemented THA. Cite this article: Bone Joint J 2015;97-B:741–8


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 299 - 305
1 Mar 2014
Bell KR Clement ND Jenkins PJ Keating JF

We performed a case–control study to compare the rates of further surgery, revision and complications, operating time and survival in patients who were treated with either an uncemented hydroxyapatite-coated Corail bipolar femoral stem or a cemented Exeter stem for a displaced intracapsular fracture of the hip. The mean age of the patients in the uncemented group was 82.5 years (53 to 97) and in the cemented group was 82.7 years (51 to 99) We used propensity score matching, adjusting for age, gender and the presence or absence of dementia and comorbidities, to produce a matched cohort receiving an Exeter stem (n = 69) with which to compare the outcome of patients receiving a Corail stem (n = 69). The Corail had a significantly lower all-cause rate of further surgery (p = 0.016; odds ratio (OR) 0.18, 95% CI 0.04 to 0.84) and number of hips undergoing major further surgery (p = 0.029; OR 0.13, 95% CI 0.01 to 1.09). The mean operating time was significantly less for the Corail group than for the cemented Exeter group (59 min [12 to 136] vs 70 min [40 to 175], p = 0.001). The Corail group also had a lower risk of a peri-prosthetic fracture (p = 0.042; OR 0.19, 95% CI 0.01 to 1.42) . There was no difference in the mortality rate between the groups. There were significantly fewer complications in the uncemented group, suggesting that the use of this stem would result in a decreased rate of morbidity in these frail patients. Whether this relates to an improved functional outcome remains unknown. Cite this article: Bone Joint J 2014;96-B:299–305


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 269 - 269
1 Sep 2005
Butt AJ Weeks G Curtin W Kaar K
Full Access

Introduction: Uncemented total hip arthroplasty has evolved significantly over the past two decades. During this period many implants with different shapes, designs and coatings have developed and are being used with variable results. We present a series of 100 uncemented hip arthroplasties using the Duraloc 100 series cup and Corail stems which have been in use at Merlin Park for the past 5 years and 1 year respectively. The CORAIL stem first introduced in 1986 has a triplanar wedge design for optimal metaphyseal fixation. The prosthesis is pointed in its distal part to allow centering in the medullary canal without cortical locking. The titanium stem is fully coated with a 150 micron thick layer of hydroyapatite. According to the Norwegian arthroplasty register the stem has 99.5% survival at 4.5 years (Havelin L1, Espheaug B, Vollset SE, Engesaeter LB). The Duraloc 100 series acetabular cups are hemispherical, porous-coated implants that are press fitted to a cavity reamed 2mm smaller than the cup diameter. Material and methods: Between January 2002 and September 2003 we carried out 100 uncemented THRs in 65 males and 35 female patients. Patients were deemed fit for uncemented hip replacement if they had good bone stock and had no co-morbid condition which might compromise bone quality. Preoperative work up was carried out to exclude any generalised diseases that might compromise bone quality, including bone density measurements where appropriate. Baseline WOMAC scores and Harris hip scores were performed pre-operatively and at latest follow up. Operative details were recorded along with post-operative complications. Patients were followed up clinically and radiologically for a period of 6 to 26 months. Results: There were 65 male patients and 35 female patients. Average age in men was 62.5 years (range 40 to 85 years) and in women was 65 years (range 48 to 86 years). Four patients had rheumatoid arthritis, the rest had osteoarthritis. The average post-op hospital stay was 12 days. The mean WOMAC score increased from 45 pre-op to 87 at the latest follow up. The average Harris hip score also increased from 52 pre-op to 92 at latest follow up. All procedures were either performed or directly supervised by the senior authors. Operations were performed through an antero-lateral approach, the femur was prepared first and a trial reamer was left in the femoral canal to minimise blood loss while the acetabulum was reamed. The average duration of surgery was 65 minutes (range 45 to 100 mins) and average intra-operative blood loss was 300mls (range 125 to 750mls). Intra-operative complications included 2 proximal femur stable split fractures, they were identified on table and fixed with circlage cables. Patients were allowed to mobilise partial weight bearing as tolerated. Complications included 4 deep venous thromboses, three superficial wound infections, one respiratory tract infection and one myocardial infarction. At the latest follow up there are no dislocations, no deep infections and no loosening of the cup or the stem. Discussion: When considering new implants and techniques in arthroplasty long term outcome of studies are necessary before any firm conclusions can be drawn regarding ultimate efficacy. This study however confirms that uncemented THRs using Duraloc cups and Corail stems is safe, involves minimal blood loss and gives good short term results. As there is no cement used, the duration of surgery is at least 15 to 20 mins less than an average cemented THR, which may be important when access to theatre is limited. The procedure is easy to learn and has well designed instrumentation. While there is no substitute for long term studies we feel that these early results are encouraging and justify continued work with the procedure in the context of a well designed prospective randomised trial comparing cemented and uncemented femoral components


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 77 - 77
1 Mar 2012
Vidalain J
Full Access

Introduction. Bio-active fixation has increasingly gained acceptance over the last two decades. However extent of the coating is still a subject of debate. We introduced in 1986, the concept of total osteointegration of a tapered stem with the hope that we could achieve durable biological fixation while preserving normal periprosthetic bone trophicity. Material and methods. Patients from our first clinical series using this stem are now eligible for 18-year follow up. Between July 1986 and December 1990, we performed 615 THA using the Corail stem (DePuy). Corail is a straight tapered stem totally coated with a 150 μ thick layer of HA following an atmospheric plasma-spray process. The mean age at surgery was 64.5 (range 16 to 95). 242 patients are now deceased (39%), 62 patients (10%) are lost to follow-up. The mean follow-up for 243 living patients on file is 17.7 years. Results. 89 THAs required component revisions: 72 cups, 9 stems, 8 “cups and stems”. 8 cups and 4 stems have been revised for aseptic loosening. Owing to the high incidence of wear-related revision, Kaplan-Meïer survivorship at 18-year follow-up, using component revision for any reason as an endpoint, was 80.7 ± 3.3 (95% confidence intervals). In contrast, Corail stem survivorship, using stem removal for any reason as an endpoint, was 95.0% ± 3.0 at 18-year follow-up, and considering aseptic loosening only, the survival probability of the stem is 98.9% ± 1.1 at 18 years. Discussion and conclusions. Therefore, despite wear and proximal osteolysis, the fixation achieved with this totally HA-coated stem remained durable through 18-year follow-up. Regarding the periprosthetic remodelling during this period, modifications of the bone pattern have been strictly limited: slight resorption at the calcar level, absence of cortical hypertrophy, anecdotic significant stress-shielding. The radiological silence is one of the paramount facts demonstrated by this prospective study


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 16 - 16
1 Jan 2011
Vidalain J
Full Access

Bio-active fixation has increasingly gained acceptance over the last two decades. However extent of the coating is still a subject of debate. We introduced in 1986, the concept of total osteointegration of a tapered stem with the hope that we could achieve durable biological fixation while preserving normal periprosthetic bone trophicity. Patients from our first clinical series using this stem are now eligible for 18-year follow up. Between July 1986 and December 1990, we performed 615 THA using the Corail stem (DePuy). Corail is a straight tapered stem totally coated with a 150 μthick layer of HA following an atmospheric plasma-spray process. The mean age at surgery was 64.5 (range 16 to 95). 242 patients are now deceased (39%), 62 patients (10%) are lost to follow-up. The mean follow-up for 243 living patients on file is 17.7 years. Eighty nine THA’s required component revisions: 72 cups, 9 stems, 8 “cups and stems”. 8 cups and 4 stems have been revised for aseptic loosening. Owing to the high incidence of wear-related revision, Kaplan-Meïer survivorship at 18-year follow-up, using component revision for any reason as an endpoint, was 80.7 ± 3.3 (95% confidence intervals). In contrast, Corail stem survivorship, using stem removal for any reason as an endpoint, was 95.0% ± 3.0 at 18-year follow-up, and considering aseptic loosening only, the survival probability of the stem is 98.9% ± 1.1 at 18 years. Therefore, despite wear and proximal osteolysis, the fixation achieved with this totally HA-coated stem remained durable through 18-year follow-up. Regarding the periprosthetic remodelling during this period, modifications of the bone pattern have been strictly limited: slight resorption at the calcar level, absence of cortical hypertrophy, anecdotic significant stress-shielding. The radiological silence is one of the paramount facts demonstrated by this prospective study


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 532 - 532
1 Oct 2010
Vidalain J
Full Access

Introduction : Bio-active fixation has increasingly gained acceptance over the last two decades. However extent of the coating is still a subject of debate. We introduced in 1986, the concept of total osteointegration of a tapered stem with the hope that we could achieve durable biological fixation while preserving normal periprosthetic bone trophicity. Material and methods: Patients from our first clinical series using this stem are now eligible for 18-year follow up. Between July 1986 and December 1990, we performed 615 THA using the Corail stem (DePuy). Corail is a straight tapered stem totally coated with a 150 μ thick layer of HA following an atmospheric plasma-spray process. The mean age at surgery was 64.5 (range 16 to 95). 242 patients are now deceased (39%), 62 patients (10%) are lost to follow-up. The mean follow-up for 243 living patients on file is 17.7 years. Results: 89 THA’s required component revisions: 72 cups, 9 stems, 8 “cups and stems”. 8 cups and 4 stems have been revised for aseptic loosening. Owing to the high incidence of wear-related revision, Kaplan-Meïer survivorship at 18-year follow-up, using component revision for any reason as an endpoint, was 80.7 ± 3.3 (95% confidence intervals). In contrast, Corail stem survivorship, using stem removal for any reason as an endpoint, was 95.0% ± 3.0 at 18-year follow-up, and considering aseptic loosening only, the survival probability of the stem is 98.9% ± 1.1 at 18 years. Discussion and Conclusions: Therefore, despite wear and proximal osteolysis, the fixation achieved with this totally HA-coated stem remained durable through 18-year follow-up. Regarding the periprosthetic remodelling during this period, modifications of the bone pattern have been strictly limited: slight resorption at the calcar level, absence of cortical hypertrophy, anecdotic significant stress-shielding. The radiological silence is one of the paramount facts demonstrated by this prospective study


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 1 - 1
1 Mar 2009
VIDALAIN J MACHENAUD A CARTILLIER J
Full Access

Bio-active fixation has increasingly gained acceptance over the last two decades. However extent of the coating is still a subject of debate. We introduced in 1986, the concept of total osteointegration of a tapered stem with the hope that we could achieve durable biological fixation while preserving a normal periprosthetic bone trophicity. Patients from our first clinical series using this stem are now eligible for 18-year follow up. Between July of 1986 and December of 1990 we performed 615 total hip arthroplasties using the Corail stem (DePuy). It is a straight tapered stem totally coated with a 150 μ thick layer of HA following an atmospheric plasma-spray process. The mean age at surgery was 64.5 (range 16 to 95 years) 242 patients are now deceased (39%), 62 (10%) patients are lost to follow-up. The mean follow-up for 243 living patients on file is 17.7years. 89 THAs required component revisions. 72 cup revisions were associated with wear and osteolysis. 8 cups and 4 stems have been revised for aseptic loosening. Owing to the high incidence of wear-related revision, Kaplan-Meïer survivorship at 18-year follow-up, using component revision for any reason as an endpoint, was 80.7±3.3 (95% confidence intervals). In contrast, Corail stem survivorship, using stem removal for any reason as an endpoint, was 95.0%±3.0 at 18-year follow-up, and considering aseptic loosening only, the survival probability of the stem is 98.9%±1.1 at 18 years. Therefore, despite wear and proximal osteolysis the fixation achieved with this totally HA-coated stem remained durable through 18-year follow-up. Regarding the periprosthetic remodelling during this period, modifications of the bone pattern have been strictly limited: slight resorption at the calcar level, absence of cortical hypertrophy, anecdotic significant stress-shielding. The radiological silence is one of the paramount facts demonstrated by this prospective study


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 49 - 49
23 Feb 2023
Sorial R Coffey S Callary S
Full Access

Roentgen Stereophotogrammetric Analysis (RSA) is the gold standard for measuring implant micromotion thereby predicting implant loosening. Early migration has been associated with the risk of long-term clinical failure. We used RSA to assess the stability of the Australian designed cementless hip stem (Paragon TM) and now report our 5-year results. Fifty-three patients were prospectively and consecutively enrolled to receive a Paragon hip replacement. Tantalum beads were inserted into the bone as per RSA protocol and in the implant. RSA x-rays were taken at baseline 1–4 days post-surgery, at 6 weeks, 6 months, 12 months, 2 years, and 5 years. RSA was completed by an experienced, independent assessor. We reported the 2-year results on 46 hips (ANZJS 91 (3) March 2021 p398) and now present the 5-year results on 27 hips. From the 2-year cohort 5 patients had died, 8 patients were uncontactable, 1 patient was too unwell to attend, 5 patients had relocated too far away and declined. At 5 years the mean axial subsidence of the stem was 0.66mm (0.05 to 2.96); the mean rotation into retroversion was 0.49˚ (−0.78˚ to 2.09˚), rotation of the stem into valgus was −0.23˚ (−0.627˚ to 1.56˚). There was no detectable increase in subsidence or rotation between 6 weeks and 5 years. We compared our data to that published for the Corail cementless stem and a similar pattern of migration was noted, however greater rotational stability was achieved with the Paragon stem over a comparable follow-up period. The RSA results confirm that any minor motion of the Paragon cementless stem occurs in the first 6 weeks after which there is sustained stability for the next 5 years. The combination of a bi-planar wedge and transverse rectangular geometry provide excellent implant stability that is comparable to or better than other leading cementless stems


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 34 - 34
1 Jun 2016
Magill P Blaney J Hill J Beverland D
Full Access

Introduction. The results of cementless total hip arthroplasty (THA) vary with data from the UK national Joint Registry being less favourable than that from the Australian registry. The senior author started using a fully cementless THA in 2005 and we aimed to gauge the performance of the implants based on their revision data. Patients and methods. Between August 2005 and March 2015, 4,802 primary THA (4,309 patients) were performed with a cementless Corail. ®. stem and a cementless Pinnacle. ®. cup. There were 2,086 (43.4%) males and 2,716 (56.6%) females with a median age of 70 years (IQR 13, Range 16–95). There were a number of changes to the surgical technique with respect to the Corail. ®. stem during the ten-year period, which we have categorised as phase 1 and phase 2. We compared the data in the two phases. Data were extracted from a prospectively maintained patient information database. Results. A total of 80 (1.67%) revisions have been performed to date (median follow-up 65.9 months, IQR 46.8, Range 0 to 121), which is equivalent to a cumulative revision risk of 2.5% at ten years. Revision rate was not significantly different in those less than 70 years old (1.63%) compared to those greater than or equal to 70 years old (1.76%, P=0.81). The leading causes of revision were instability (n=22, 0.46%), infection (n=20, 0.42%) and aseptic loosening of the stem (n=15, 0.31%). More collarless stems than collared stems have been revised. Phase 2 changes in surgical technique resulted in cessation of collarless stem use, a small but significant increase in mean stem size, and a paradoxical decrease in iatrogenic femoral fracture. Conclusions. The overall revision rates of the Corail. ®. stem and Pinnacle. ®. cup in this series are comparable to the best performing THA in equivalent registry data. Instability was the leading cause of revision but these data did not identify a causative factor. The changes in infection rate in this series are possibly influenced by changes in local antibiotic prophylaxis policy. There is a learning curve for the cementless stem as seen here by a reduction in revisions for aseptic loosening and iatrogenic femoral fracture during the ten-year period. We believe that collared stems, avoidance of undersizing and surgical technique focusing on primary stability are the key aspects


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 36 - 36
1 May 2019
Syed F Magra M Saunders P Ugwuoke A Young S
Full Access

Introduction. Primary fixation in uncemented Total Hip Replacement (THR) is achieved by implanting an appropriately sized stem. Last year, in our pilot study, we classified undersizing & reported the incidence of subsidence & radiolucent lines (RLL) in undersized uncemented stems. Now we report on a larger cohort of patients, reporting undersizing and its association with radiolucent lines and subsidence. Secondarily we report on the effect of using a collar, patients' BMI, and in a smaller group the five-year failure rate. Methods. A retrospective review of electronic records of 1337 cases who underwent THR using the Corail stem was carried out. 1204 (Collared 1042, Uncollared 162) had a minimum follow up of 1 year, 693 of those had a follow up of at least 5 years. Radiological review was carried out by 2 independent investigators. Results. 19.77% stems were undersized. There was significantly higher incidence of subsidence & RLL in undersized stems with more than 1 year follow up. There no significant increase in incidence of RLL in those with BMI greater than 30 (16.88% vs 18.81%). Analysis of undersized collared stems demonstrated that even in this sub group undersizing is associated with increased incidence of RLL (P 0.00001) & subsidence (P 0.0003). A five year follow up, the revision rate for aseptic loosening of stem was 3.09% in undersized stems & 0.29% in appropriately sized stems (P 0.06). Conclusions. Our study indicates undersizing of uncemented stems is associated with poorer radiological outcomes & there's a trend of higher revision rate at 5 year follow up. This reinforces the importance of implanting appropriately sized stem, as undersizing can potentially compromise stem survival in uncemented total hip arthroplasty


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 8 - 8
1 Apr 2019
Wilson C Critchely O Callary S Campbell D
Full Access

Introduction & aims. The magnitude and pattern of acceptable migration in clinically successful cementless stems is not well understood. Radiostereometric analysis (RSA) is a well-recognised method of assessing implant migration. Previous studies have reported long term RSA results for cemented stems. The aim of this study was to assess the long-term migration characteristics of the Corail hydroxyapatite-coated cementless stem at 10 years using RSA. Method. A prospective cohort of 30 patients undergoing primary total hip arthroplasty for primary hip osteoarthritis were enrolled into a study to characterise the migration behaviour of a cementless stem. Tantalum markers were attached to the stem and placed in the bone intraoperatively, allowing for RSA measurements to be taken in vivo. Previous 5-year results have been presented. A total of 14 patients (total 15 hips, one bilateral) with mean age 82 years (range, 69–92 years) underwent repeat long-term RSA radiographs at minimum 10 years post op. The mean time to follow up was 13.9 years (range, 13.3–14.4 years). The RSA radiographs were analysed to assess for implant rotation and translation. Results. None of the 14 patients (15 hips) followed up have been revised. The migration (rotation and translation) at 6 months, 1 year, 2 years, and 6 years has been described previously. No stems had additional subsidence of more than 0.25 mm between 6 months and 6 years. The resultant mean subsidence between 2 years and 6 years was 0.03 mm, which is below the limit measurable by RSA. The long-term, 10-year results, on implant rotation and translation will be presented. Conclusions. The Corail stem exhibited variable subsidence within the first 6 months after which there is persistent stabilisation through to 6 years. 10-year results on long-term migration show no further migration. These results can be used as a gold standard for other uncemented stems


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 6 - 6
1 Feb 2017
Al-Dirini R Huff D Taylor M
Full Access

Introduction. Successful designs of total hip replacement need to be robust to surgery-related variability. Until recently, only simple parametric studies have explored the influence of surgical variability [1]. This study presents a systematic method for quantifying the effect of variability in positioning on the primary stability of femoral stems using finite element (FE) models. Methods. Patient specific finite element models were generated of two femurs, one male and one female. An automated algorithm positioned and sized a Corail stem (DePuy Synthes, Warsaw) into each of the femurs to achieve maximum fill of the medullary canal without breaching into the cortical bone boundaries.. Peak joint contact and muscle forces associated with level gait were applied[2] and scaled to the body mass of each subject, whilst the distal femur was rigidly constrained. The space prone to surgical variation was defined by the “gap” between the stem and the inner boundary of the cortical bone. The anterior/posterior and the varus/valgus alignment of the stem within this “gap” was controlled by varying the location of the points defining the shaft axis. The points were taken at 20% and 80% of the stem length (Figure 1). The anteversion angle as well as the vertical and the medial position of the stem were controlled by changing the location of the head centre within the femoral head radius. The location of these points was varied using Latin Hypercube sampling to generate 200 models per femur, each with a unique stem position. The risk of failure was evaluated based on stem micromotion, equivalent strains, and percentage of the bone-prosthesis contact area experiencing more than 7000 µstrains [3]. Results. The range of positions covered in this study adhered to the anatomy of the subjects (Table 1) and none of the stem positions breached into the cortical bone of the femur. The 90th percentile peri-prosthetic strains were between 1770 – 4792 µstrains for the male subject, and 2710 – 11260µstrains for the female subject. The 90th percentile micromotion was between (15.6 – 47) µm for the male subject, and (42.4 – 102.4) µm for the female subject. The percentage of the contact area experiencing more than 7000 µstrains was between (0% – 0.33%) for the male subject, and (0% – 12%) for the female subject. Discussion. A systematic method for studying the effect of surgical-related variation on primary stability was presented its applicability demonstrated on two femurs. The study found that variation in stem position may result in large variation (up to 1.5 times the baseline position) in strains and micromotions. The magnitude Up to three times the magnitudes for the ideal stem position. This method can be applied to larger samples to understand the influence of different alignment parameters on the primary stability of femoral stems


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 10 - 10
1 Dec 2016
Callaghan J
Full Access

Three basic design concepts of cementless femoral fixation have emerged. They include: anatomic designs, straight stem designs, and tapered designs. In addition, there have been modular designs. The most successful have been designs that have a metaphyseal sleeve with a tapered stem. A more recent newer concept has been the double taper neck designs which have not performed well in general. Anatomic Stem Designs: The rationale for an anatomic stem design was to design a component that matched the sagittal plane bow of the femur. The APR (Centerpulse, Austin, Texas) and the PCA (Howmedica, Rutherford, New Jersey) were the initial designs. Although these designs provided excellent micromotion stability, they are not used in their present length today because they could not fit in to all femurs. Straight Stem Designs: The concept of a straight stem design was to machine the femur to accept the prosthesis. This was done with diaphyseal reaming, proximal broaching, and preparing a proximal triangle to accommodate the proximal metaphyseal portion of the stem. These had previously, and still do, come in proximally coated and distally coated designs. They have proven to be durable long term. The AML fully coated stem (DePuy, Warsaw, Indiana) was and still is the prototype device. Tapered Stem Designs: The most popular designs today are the tapered stems. They are inserted either by a broach only, or ream and broach technique. Some only taper in the ML plane and are flat in the AP plane. These are called ML taper or blade devices (Taperloc and Trilock). These are usually inserted broach only. Some have a double taper with proximal fill and include the Zweymuller stem (Zimmer, Warsaw, Indiana), the Omnifit stem (Stryker, Mahwah, New Jersey), the Summit stem, and the Corail stem (both DePuy, Warsaw, Indiana). Some are hydroxyapatite coated (Omnifit and Corail), some are porous coated (Summit), and some are only grit blasted (Zweymuller). Some are broach only including the Zweymuller and Corail, and some are broach and ream including the Omnifit and Summit. Some are tapered throughout, one of which is a Wagner type design, Trilogy (Zimmer, Warsaw, Indiana). These Wagner type devices are useful in abnormal anatomy (CDH and Perthes). Modular Stem and Dual Modular Neck Designs: Metaphyseal sleeve modular stem designs are extremely versatile and can be inserted press fit into just about any femoral anatomy. They are most commonly utilised in cases of hip dysplasia with marked femoral anteversion. The S-ROM device is the prototype design. The long term concern with these as well as the double neck tapered devices is fretting and corrosion at the extra modular junctions. Short Stem Designs: Short stem designs were developed to provide metaphyseal only fixation and to enable easy insertion through small incision techniques, especially those performed through anterior and antero-lateral approaches


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 79 - 79
1 Mar 2010
Balay B Vidalain J
Full Access

Introduction and Objectives: During 1986, we began working with the concept of osteointegration of a fully-coated stem in the hope of achieving a lasting fixation and preservation of normal trophic bone surrounding the prosthesis. Materials and Methods: Between July 1986 and December 1990, we implanted 615 Corail stems. Mean age of the patients was 64.5 years; 242 patients died (39%), 62 patients (10%) have been lost to follow-up. Mean follow-up of the 243 patients still alive was 17.7 years. Results: 89 revisions: 72 acetabular cups, 8 bipolar, 9 stems. If we consider the survival of the stem alone, the Kaplan curve is 95.0% +/− 3.0, if we take into account only aseptic loosening, the probability of stem survival at 18 years is 98.9 +/− 1. Discussion and Conclusions: At 18 years follow-up the fixation of a fully HA-COATED stem is still trustworthy. A major part of this prospective study was the lack of symptoms surrounding the prosthesis determined by X-ray imaging


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 548 - 554
1 Jun 2024
Ohyama Y Minoda Y Masuda S Sugama R Ohta Y Nakamura H

Aims

The aim of this study was to compare the pattern of initial fixation and changes in periprosthetic bone mineral density (BMD) between patients who underwent total hip arthroplasty (THA) using a traditional fully hydroxyapatite (HA)-coated stem (T-HA group) and those with a newly introduced fully HA-coated stem (N-HA group).

Methods

The study included 36 patients with T-HA stems and 30 with N-HA stems. Dual-energy X-ray absorptiometry was used to measure the change in periprosthetic BMD, one and two years postoperatively. The 3D contact between the stem and femoral cortical bone was evaluated using a density-mapping system, and clinical assessment, including patient-reported outcome measurements, was recorded.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 107 - 107
1 Sep 2012
Boldt J
Full Access

Femoral stress shielding in cementless THA is a potential complication commonly observed in cementless distally loading press-fit stems. Long-term metaphyseal fixation and proximal load transfer is desired. Is routine autologous metaphyseal bone impaction and proximal primary stability an answer to this goal?. This prospective study describes long-term femoral bone remodeling and load transfer in cementless THA at a mean of 17 years (range: 15 to 20 years) in 208 consecutive fully HA-coated stems (Corail). All primary THA were performed by one group of surgeons between 1986 and 1991. The concept of surgical technique included impaction of autologous metaphyseal bone using bland femoral broaches until primary stability was achieved without distal press-fit. Radiographic evaluation revealed a total of five (2.4%) stems with periprosthetic osteolysis, which were associated with eccentric polyethylene wear. They were either revised or awaiting revision. The remaining 97.6% stems revealed desired proximal load transfer in the metaphysis (52%) or in both metaphysis and diaphysis (48%). Distal stress shielding was not observed and was considered to be related to: impaction of metaphyseal bone, bland broaches, HA coating, and prosthetic design. Biological autologous bone impaction of the metaphysis provides both primary stem stability and successful longterm osteointegration with the Corail stem after 20 years. The surgical technique of proximal autologous bone impaction rather than extraction of cancellous bone material and the use of a fully HA coated stem without distal press-fit show encouraging longterm results in THA


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 34 - 34
1 Sep 2014
Schepers A v d Jagt D Breckon A
Full Access

Purpose Of Study. The study was started in 2004 to determine the best bearing surface in the long term, and to measure the metal ion levels generated by each of the bearing surfaces. We present the latest updated results. Material and methods. A prospective randomised study was started in 2004 to compare the wear characteristics of Ceramic on X linked Polyethylene (C.O.P.), Ceramic on Ceramic (C.O.C), Ceramic on Metal (C.O.M.) and Metal on Metal (M.O.M) bearings. The level of Cobalt and Chrome ions in red blood cells have been documented at serial intervals, using the ICP – MS method. Aside from the bearing surfaces the rest of the implant is standard, using a Pinnacle Cup, Corail Stem and 28mm heads. 256 Cases were enrolled on the study. To date 71 cases have been lost due to death (26), revision (9) and lost to follow up (36), leaving us with 185 for follow-up. An even spread of cases in each bearing surface are still available for follow up, viz. 46 C.O.P, 48 C.O.C., 44 C.O.M. and 47 M.O.M. Average follow up is currently 4.8 years, ranging up to 9 years. Results. To date no difference could be determined on the wear properties, with all bearings being acceptable. The only wear that could be measured was with C.O.P. bearings. Metal ion levels at no stage have been raised in the C.O.P. and C.O.C. bearings. Initially C.O.M. bearings had lower levels than M.O.M. bearings, but by 36 months were virtually the same with the mean below the 2ug/L level. At 60 month follow up values on almost half of the cases show markedly lower metal ions in the C.O.M. group. Outliers in both groups were associated with poorly placed cups, with the C.O.M. bearing being more forgiving that the M.O.M. group. Conclusion. To date the C.O.P. and C.O.M. bearings are performing the best of the 4 bearing combinations. NO DISCLOSURES


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 1 - 1
1 Mar 2009
Boldt J Cartillier J Machenaud A Vidalain J
Full Access

We present a prospective study focused on radiographic long-term outcomes and bone remodeling at a mean of 17.0 years (range: 15 to 20) in 208 cementless fully HA-coated femoral stems (Corail®, DePuy, Johnson & Johnson). Total hip replacements in this study were performed by three members of the surgeon design team (Artro Group) in France between 1986 and 1991. Radiographic evaluation focused on periprosthetic osteolysis, bone remodeling, osseous integration, subsidence, metaphyseal or diaphyseal load transfer, and femoral stress shielding. The radiographs were digitized and examined with contrast enhancing software (DICOM Anonymizer 1.1.2) for analysis of the trabecular architecture. Radiographic signs of aseptic stem loosening were visible in two cases (1%). Three stems (1.4%) showed metaphyseal periprosthetic osteolysis in two of seven Gruen zones associated with eccentric polyethylene wear awaiting metaphyseal bone grafting and cup liner exchange. One stem (0.5%) was revised due to infection. No stem altered in varus or valgus alignment more than two degrees and mean subsidence was 0.1 mm (range: 0 to 2) after a mean of 17.0 years. Five stems (2.4%) required or are awaiting revision surgery. Trabecular orientation and micro-anatomy suggested proximal load-transfer patterns in all except three cases (98.6%). Combined metaphyseal and diaphyseal osseo-integration and bone remodeling were visible in one hundred stems (48%). Diaphyseal stress shielding and cortical thickening were observed in three stems (1.4%). Other radiographic features are discussed in depth. This long-term study of 208 fully HA-coated Corail stems showed highly satisfactory osseo-integration and fixation in 97.6% after a mean of 17.0 years follow-up


Bone & Joint 360
Vol. 13, Issue 1 | Pages 13 - 16
1 Feb 2024

The February 2024 Hip & Pelvis Roundup360 looks at: Trial of vancomycin and cefazolin as surgical prophylaxis in arthroplasty; Is preoperative posterior femoral neck tilt a risk factor for fixation failure? Cemented versus uncemented hemiarthroplasty for displaced intracapsular fractures of the hip; Periprosthetic fractures in larger hydroxyapatite-coated stems: are collared stems a better alternative for total hip arthroplasty?; Postoperative periprosthetic fracture following hip arthroplasty with a polished taper slip versus composite beam stem; Is oral tranexamic acid as good as intravenous?; Stem design and the risk of early periprosthetic femur fractures following THA in elderly patients; Does powered femoral broaching compromise patient safety in total hip arthroplasty?


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 89 - 90
1 Mar 2009
Havelin L Hallan G Dybvik E
Full Access

There has been no general agreement about the use of uncemented hip prostheses in patients with rheumatoid arthritis (RA). In the present study we compared the results for the cemented and uncemented stem that most commonly had been used in RA patients in the Norwegian Arthroplasty Register. MATERIAL AND Methods: All hospitals in the country participate and report their primary and revision operations of RA patients to the register. This group constitutes 3.5% of the patients in the register. For the present study we included primary prosthesis operations in RA patients during 1987–2005, where either the Corail or the Charnley stem, the most commonly used uncemented and cemented stems, had been used. We calculated survival by the Kaplan-Meier method and by Cox multiple regression with adjustment for age and gender. Results: The 10 years survival of the total hip prostheses were 81 % in the uncemented group and 89 % in the cemented group. However, the revisions of the uncemented prostheses were mainly performed due to cup problems. With revision of stem for any reason as end-point, the 10-year survival was 98% for the fully HA-coated uncemented Corail stem and 91% for the cemented Charnley stem. In the Cox regression, the risk for revision of the Charnley stem was 3.4 times increased compared to the Corail (95% CI: 1.43–8.06. P< 0.006). Also revision due to aseptic stem loosening was statistically significant increased for the Charnley stem, whereas there was no significant difference concerning revision due to dislocation or periprosthetic fracture. Conclusions: Both stems had a 10-years survival better than 90%, and the uncemented stem had excellent results in RA patients. However, the uncemented total hip prostheses had inferior results compared to the cemented total hip prostheses due to problems with the uncemented cups that had been used in association with this uncemented stem


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 75 - 75
1 Sep 2012
Hansen KEP Maansson L Olsson M
Full Access

Background. It is unclear which form of anaesthesia is the most favourable in primary total hip replacement (THR) surgery. A recently published systematic review of modern anaesthesia techniques in primary THR surgery (Macfarlane 2009) was not able to show any convincing benefit of regional or general anaesthesia. One retrospective study that examined anaesthesia and leg length (Sathappan 2008), found an increased incidence of leg length difference > 5 mm in those patients who were operated with regional anaesthesia. Our department used a mini invasive approach in supine as standard procedure in THR. The type of anaesthesia that is chosen is up to the individual anaesthetist. Purpose. We wanted to see if there was any correlation between type of anaesthesia and leg length, total time spent in theatre and recovery room, postoperative hospital stay, blood loss or operating time in primary THR surgery with a mini invasive approach in supine. Materials and Methods. Our study was a retrospective study of 170 primary THR patients. All patients received an uncemented Corail stem and a cemented Marathon cup. Patients with abnormal anatomy, BMI > 46, simultaneous removal of internal fixation or incomplete data were excluded in the analysis. Radiograpic leg length was measured using the inter teardrop line and the lesser trochanter. Results. 99 patients were operated on with spinal anaesthesia and 71 with total intravenous anaesthesia (TIVA). There were 65% women in both groups. Average age was 74 years (32–95) in the spinal anaesthesia group and 67 years (38–93) in the TIVA group. We found no significant difference in the average operating time (spinal 65 min, TIVA 64 min), drop in haemoglobin to the first postoperative day (spinal 16%, TIVA 16%), postoperative hospital stay (Spinal 1.4 days, TIVA 1.4) or in transfusion rate (spinal 1%, TIVA 1.4%). We found a significant difference in the proportion of patients with a leg length difference of more than 7 mm (Spinal 22%, TIVA 6%, p = 0.02) and the average total time spent in theatre and post-operative department (spinal 325 min, TIVA 293 min, p < 001). Discussion. The study is retrospective and is therefore fettered by the limitations inherent in such a study. Our study seems to confirm the earlier findings that the type of anaesthesia can affect leg length in primary THR. It is speculated that spinal anaesthesia has a more unpredictable effect on muscular tension which could explain this


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 2 - 2
1 Mar 2009
HARDY D
Full Access

Osteointegration of HA coated devices is well demonstrated. An abundant experimental material exists, allowing to describe the various properties of HA (early osteointegration, sealing effect, gap healing effect, etc…). Various side-effects have been described (third body wear of HA debris, delamination of the proximal coating etc…). Thus controversy still exists, despite a more and more convincing clinical experience. The role of human retrievals is therefore crucial to determine the exact role of all these parameters in the natural life of the implant throughout the years. 49 human well-functioning explants have been retrieved during systemic autopsies in elderly patients previously operated for a displaced fracture of the neck with a Corail® implant. Delays of implantation vary from 5 days to 10 years. All these specimens have been processed for optical microscopy, electronic microscopy with backscattering. This constitutes the longest report on one single implant and the retrievals are evenly distributed over this ten-year period. Several histomorphometric parameters were measured in the different Gruen’s zones: cortical bone density, cortical bone thickness, density of endosteal bone. 3 steps are recognized:. Bone formation around the implant appears early after surgery. Multiple units of bone formation go to coalescence as soon as 6 weeks and develop thereafter, leading to osteointegration. Bone remodelling reorganizes the architecture of connecting trabeculae according to the mechanical stresses resulting from the presence of the implant. Compression areas are generally the seat of broad and interconnected trabeculae, whereas tensile stresses areas display the presence of long, thin, unconnected and often parallel trabeculae. Very broad and short trabeculae are often seen at the level of the corners. Coating resorption is seen in every specimen beyond one year of implantation, predominantly in the areas with less bone coverage. Release of HA particles in the joint cavities was never encountered. Some metallic particles, originating from the femoral ball are commonly seen in the polyethylene. HA particles (presumably scratched off the prosthesis during insertion?...) have never been identified in the heterotopic ossifications. We conclude that the osteointegration of the Corail stems is a reliable phenomenon with a reproducible sequence of events. It lasts even after the disappearance of the coating in a 5–10 years period. The presence of the stem provokes a remodelling of the cortices but the presence of a total coating and its longer duration at the level of the tip does not induce a disappearance of the proximal bone or a loose of the proximal fixation


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 313 - 313
1 May 2010
Varnum C Vester T Revald P Kjærsgaard-Andersen P
Full Access

Introduction: There are ongoing concerns regarding metal wear debris following the use of metal-on-metal (MonM) bearings for hip surface and total arthroplasty. A Type IV Hypersensitivity reaction to MonM articulations has previously been identified (aseptic lymphocyte dominated vasculitis associated lesion, ALVAL) but little is known of its incidence, diagnosis or management. Persisting groin pain in MonM patients may be undiagnosed ALVAL. At our single centre we have reviewed and compared three types of MonM articulations to examine the incidence of ALVAL and to identify trends. Methods: The resurfacing group comprised 250 patients with the ASR prosthesis. In the resurfacing hybrid total hip replacement (THR) group there were 86 patients implanted with an ASR head on a stem. The final group comprised of 625 patients with a MonM THR using a 36mm Pinnacle head. Both the S-ROM and the Corail stems were used in the THR groups. Patients with persisting and activity-restricting groin pain had tests for infection. Patients were counselled and revision was offered if ALVAL was suspected from the clinical picture, blood results and the aspiration result. Specimens for microbiological and histological analysis were taken at the time of revision. Results: We found 5 cases of histologically proven ALVAL in the absence of infection in 961 patients. The incidence was: 1.2% in the resurfacing group, 2.3% of Resurfacing Hybrid THR group and 0 in the 36 mm THR group. All 5 cases were in female patients. Only 1 case had any radiological abnormality. One patient was initially revised from a resurfacing to a 36mm MonM THR without clinical success. All patients have now been revised to ceramic-on-ceramic bearings with improvements in outcome. Discussion: ALVAL may be under-diagnosed. The 5 patients we describe showed good clinical recovery following their primary procedure. However, activity levels decreased and pain increased at 6–12 months post-op. All described non-specific systemic symptoms. On examination, a painful straight leg raise was a characteristic finding. This may result from the significant effusion found around the hip at each revision. Fluid aspirated from these hips was of a characteristic colour (green grey) and viscosity. The failure of the revision of a resurfacing to a smaller MonM bearing highlights the problem of sensitisation to the metal debris. Any subsequent revision to a MonM bearing is unlikely to improve clinical outcome. This finding is consistent with previous reports in the literature. Our results suggest the incidence of ALVAL may be higher that previously thought. We suggest all patients with significant groin pain should have inflammatory markers tests and a hip aspiration performed. In the absence of infection, revision to an alternative bearing surface may be indicated


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 301 - 302
1 May 2010
Jameson S Ramisetty N Langton D Webb J Logishetty R Nargol A
Full Access

Introduction: There are ongoing concerns regarding metal wear debris following the use of metal-on-metal (MonM) bearings for hip surface and total arthroplasty. A Type IV Hypersensitivity reaction to MonM articulations has previously been identified (aseptic lymphocyte dominated vasculitis associated lesion, ALVAL) but little is known of its incidence, diagnosis or management. Persisting groin pain in MonM patients may be undiagnosed ALVAL. At our single centre we have reviewed and compared three types of MonM articulations to examine the incidence of ALVAL and to identify trends. Methods: The resurfacing group comprised 250 patients with the ASR prosthesis. In the resurfacing hybrid total hip replacement (THR) group there were 86 patients implanted with an ASR head on a stem. The final group comprised of 625 patients with a MonM THR using a 36mm Pinnacle head. Both the S-ROM and the Corail stems were used in the THR groups. Patients with persisting and activity-restricting groin pain had tests for infection. Patients were counselled and revision was offered if ALVAL was suspected from the clinical picture, blood results and the aspiration result. Specimens for microbiological and histological analysis were taken at the time of revision. Results: We found 5 cases of histologically proven ALVAL in the absence of infection in 961 patients. The incidence was: 1.2% in the resurfacing group, 2.3% of Resurfacing Hybrid THR group and 0 in the 36 mm THR group. All 5 cases were in female patients. Only 1 case had any radiological abnormality. One patient was initially revised from a resurfacing to a 36mm MonM THR without clinical success. All patients have now been revised to ceramic-on-ceramic bearings with improvements in outcome. Discussion: ALVAL may be under-diagnosed. The 5 patients we describe showed good clinical recovery following their primary procedure. However, activity levels decreased and pain increased at 6–12 months post-op. All described non-specific systemic symptoms. On examination, a painful straight leg raise was a characteristic finding. This may result from the significant effusion found around the hip at each revision. Fluid aspirated from these hips was of a characteristic colour (green grey) and viscosity. The failure of the revision of a resurfacing to a smaller MonM bearing highlights the problem of sensitisation to the metal debris. Any subsequent revision to a MonM bearing is unlikely to improve clinical outcome. This finding is consistent with previous reports in the literature. Our results suggest the incidence of ALVAL may be higher that previously thought. We suggest all patients with significant groin pain should have inflammatory markers tests and a hip aspiration performed. In the absence of infection, revision to an alternative bearing surface may be indicated


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 13 - 13
1 Apr 2018
Moharamzadeh D Molisani D Piarulli G Noto G Andreoletti G
Full Access

Aim of the study was to analyse the modifications of the pre-op and post-op femoral off-set after cementless total hip replacement. During an 18-month period, from January 2015 to June 2016, we retrospectively analysed data of 79 (n = 81 hips) patients (M:F = 31:48), with an average age of 70.38 yrs ± 10.05, who consecutively affered to our Department and underwent cementless total hip replacement for primary osteoarthritis with Pinnacle Gription. TM. cup and Corail. TM. stem (Depuy). All cases of infections and revision surgery were excluded. Inclusion criteria: postero-lateral approach, 2 dedicated surgeons. All patients were clinically and radiographically evaluated at 4-months and 1-year postop. Preop and postop femoral off-set were calculated using Impax Agfa software. Average preop HHS was 46.7 ± 7.7; at 4-months post-op 86.4 ± 5.7; at 1-year post-op 90.0 ± 5 (the improvement had a statistically significant p-value). There was no statistical significant difference between the preop and postop off-set values obtained (t-student test). In 38 (46.9%) hips we increased the femoral off-set and we analysed using χ₂-test if there was a correlation with hip pain, HHS and dislocation. There was no statistical significance. Our overall results show good and excellent clinical results at 1 year follow-up in cementless total hip replacement. We believe that our pre-op digital planning of the implant and the offset obtained is a crucial step in determining these results


Bone & Joint Open
Vol. 2, Issue 5 | Pages 293 - 300
3 May 2021
Lewis PM Khan FJ Feathers JR Lewis MH Morris KH Waddell JP

Aims

“Get It Right First Time” (GIRFT) and NHS England’s Best Practice Tariff (BPT) have published directives advising that patients over the ages of 65 (GIRFT) and 69 years (BPT) receiving total hip arthroplasty (THA) should receive cemented implants and have brought in financial penalties if this policy is not observed. Despite this, worldwide, uncemented component use has increased, a situation described as a ‘paradox’. GIRFT and BPT do, however, acknowledge more data are required to support this edict with current policies based on the National Joint Registry survivorship and implant costs.

Methods

This study compares THA outcomes for over 1,000 uncemented Corail/Pinnacle constructs used in all age groups/patient frailty, under one surgeon, with identical pre- and postoperative pathways over a nine-year period with mean follow-up of five years and two months (range: nine months to nine years and nine months). Implant information, survivorship, and regular postoperative Oxford Hip Scores (OHS) were collected and two comparisons undertaken: a comparison of those aged over 65 years with those 65 and under and a second comparison of those aged 70 years and over with those aged under 70.


Bone & Joint Open
Vol. 2, Issue 9 | Pages 696 - 704
1 Sep 2021
Malhotra R Gautam D Gupta S Eachempati KK

Aims

Total hip arthroplasty (THA) in patients with post-polio residual paralysis (PPRP) is challenging. Despite relief in pain after THA, pre-existing muscle imbalance and altered gait may cause persistence of difficulty in walking. The associated soft tissue contractures not only imbalances the pelvis, but also poses the risk of dislocation, accelerated polyethylene liner wear, and early loosening.

Methods

In all, ten hips in ten patients with PPRP with fixed pelvic obliquity who underwent THA as per an algorithmic approach in two centres from January 2014 to March 2018 were followed-up for a minimum of two years (2 to 6). All patients required one or more additional soft tissue procedures in a pre-determined sequence to correct the pelvic obliquity. All were invited for the latest clinical and radiological assessment.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 110 - 114
1 Mar 2024
Yee AHF Chan VWK Fu H Chan P Chiu KY

Aims

The aim of this study was to evaluate the survival of a collarless, straight, hydroxyapatite-coated femoral stem in total hip arthroplasty (THA) at a minimum follow-up of 20 years.

Methods

We reviewed the results of 165 THAs using the Omnifit HA system in 138 patients, performed between August 1993 and December 1999. The mean age of the patients at the time of surgery was 46 years (20 to 77). Avascular necrosis was the most common indication for THA, followed by ankylosing spondylitis and primary osteoarthritis. The mean follow-up was 22 years (20 to 31). At 20 and 25 years, 113 THAs in 91 patients and 63 THAs in 55 patients were available for review, respectively, while others died or were lost to follow-up. Kaplan-Meier analysis was performed to evaluate the survival of the stem. Radiographs were reviewed regularly, and the stability of the stem was evaluated using the Engh classification.


Bone & Joint Research
Vol. 11, Issue 3 | Pages 180 - 188
1 Mar 2022
Rajpura A Asle SG Ait Si Selmi T Board T

Aims

Hip arthroplasty aims to accurately recreate joint biomechanics. Considerable attention has been paid to vertical and horizontal offset, but femoral head centre in the anteroposterior (AP) plane has received little attention. This study investigates the accuracy of restoration of joint centre of rotation in the AP plane.

Methods

Postoperative CT scans of 40 patients who underwent unilateral uncemented total hip arthroplasty were analyzed. Anteroposterior offset (APO) and femoral anteversion were measured on both the operated and non-operated sides. Sagittal tilt of the femoral stem was also measured. APO measured on axial slices was defined as the perpendicular distance between a line drawn from the anterior most point of the proximal femur (anterior reference line) to the centre of the femoral head. The anterior reference line was made parallel to the posterior condylar axis of the knee to correct for rotation.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1045 - 1051
1 Oct 2023
Turgeon TR Righolt CH Burnell CD Gascoyne TC Hedden DR Bohm ER

Aims

The primary aim of this trial was to compare the subsidence of two similar hydroxyapatite-coated titanium femoral components from different manufacturers. Secondary aims were to compare rotational migration (anteversion/retroversion and varus/valgus tilt) and patient-reported outcome measures between both femoral components.

Methods

Patients were randomized to receive one of the two femoral components (Avenir or Corail) during their primary total hip arthroplasty between August 2018 and September 2020. Radiostereometric analysis examinations at six, 12, and 24 months were used to assess the migration of each implanted femoral component compared to a baseline assessment. Patient-reported outcome measures were also recorded for these same timepoints. Overall, 50 patients were enrolled (62% male (n = 31), with a mean age of 65.7 years (SD 7.3), and mean BMI of 30.2 kg/m2 (SD 5.2)).


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 130 - 136
1 Mar 2024
Morlock M Perka C Melsheimer O Kirschbaum SM

Aims

Despite higher rates of revision after total hip arthroplasty (THA) being reported for uncemented stems in patients aged > 75 years, they are frequently used in this age group. Increased mortality after cemented fixation is often used as a justification, but recent data do not confirm this association. The aim of this study was to investigate the influence of the design of the stem and the type of fixation on the rate of revision and immediate postoperative mortality, focusing on the age and sex of the patients.

Methods

A total of 333,144 patients with primary osteoarthritis (OA) of the hip who underwent elective THA between November 2012 and September 2022, using uncemented acetabular components without reconstruction shells, from the German arthroplasty registry were included in the study. The revision rates three years postoperatively for four types of stem (uncemented, uncemented with collar, uncemented short, and cemented) were compared within four age groups: < 60 years (Young), between 61 and 70 years (Mid-I), between 71 and 80 years (Mid-II), and aged > 80 years (Old). A noninferiority analysis was performed on the most frequently used designs of stem.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 21 - 21
1 Jun 2017
Buttaro M Zanotti G Comba F Slullitel P Piccaluga F
Full Access

Femoral offset restoration is related to low rates of wear and dislocation. Replication of the native hip anatomy improves prosthesis survival, whereas increasing the femoral offset elevates the torque stresses, thus inducing a risk of suboptimal stem fixation. Although the Corail (DePuy Synthes, St Priest, France) uncemented stem has an excellent record of fixation, an unexpectedly number of aseptic loosenings has been noted in our institution. We sought to characterize the clinical parameters observed in a group of patients who have experienced metaphyseal aseptic loosenings with the collarless version of the Corail uncemented femoral component; describe the radiographic findings in this group of patients; expose the intraoperative findings in the cases that needed revision surgery and to calculate a possible frequency of this complication. We present a series of 15 metaphyseal debondings of the collarless version of the Corail uncemented stem in primary total hip arthroplasty. Eleven men and four woman with an average age of 60 years old (range: 42 to 81 years old) and a previous history of osteoarthritis presented with thigh pain and limping at an average of 33 months postoperative (range: 5 to 100 months). Seven cases presented a Dorr´s classification type A femur and 8 cases a type B femur. In 10 of the 15 cases a 36 mm ceramic on ceramic bearing surface was implanted and in 5 a 28 mm diameter ceramic on polyethylene pair. Radiographic assessment of the failures evidenced an increase in femoral offset of 6.2 mm in average (range: 0 to 17 mm). Nine of the 15 cases had a standard offset stem and 3 an extended offset stem. Leg length discrepancy was in average 2.4 mm (range: 0 to 8 mm). None of the failures presented a more than 2 mm subsidence. Alignment of these stems was in average 2.1 degrees of varus (range: 0 to 5 degrees). Six cases were revised to a long cemented or uncemented stem, 2 cases were lost and 7 cases are awaiting revision surgery. Although the incidence of this complication was low (15 failures in 855 cases in 10 years = 1.75%), we are concerned about the real magnitude of this problem, as this mode of failure was observed up to 8 years after implantation. Enhanced lateralization of the hip, independently of the type of stem, may have played a role in the infrequent early failures of this popular design. Routine use of “fine tunning” preoperative planning in order to avoid offset enhancement is strongly reccommended, as this was the only suspected factor that was present in almost all the failures we observed


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 100 - 100
1 Feb 2017
Bragdon C Donahue G Lindgren V Galea V Madanat R Muratoglu O Malchau H
Full Access

Introduction. Complication and revision rates have shown to be high for all metal-on-metal (MoM) bearings, especially for the ASR Hip System (ASR hip resurfacing arthroplasty (HRA) and ASR XL total hip arthroplasty (THA)). This prompted the global recall of the ASR Hip System in 2010. Many studies have previously explored the association between female gender and revision surgery MoM HRA implants; yet less research has been dedicated to exploring this relationship in MoM THA. The first purpose of this study was to assess the associations between gender and implant survival, as well as adverse local tissue reaction (ALTR), in patients with MoM THA. Secondly, we sought to report the differences between genders in metal ion levels and patient reported outcome measures (PROMs) in patients with MoM THA. Methods. The study population consisted of 729 ASR XL THA patients (820 hips) enrolled from September 2012 to June 2015 in a multicenter follow-up study at a mean of 6.4 (3–11) years from index surgery. The mean age at the time of index surgery was 60 (22–95) years and 338 were women (46%). All patients enrolled had complete patient and surgical demographic information, blood metal ion levels and PROMs obtained within 6 months, and a valid AP pelvis radiograph dating a maximum of 2 years prior to consent. Blood metal ion levels and PROMs were then obtained annually after enrollment. A sub-set of patients from a single center had annual metal artifact reduction sequence (MARS) MRI performed and were analyzed for the presence of moderate-to-severe ALTR. Results. Eighty-nine hips (11%) were revised during the study period. Forty-five of the 338 men underwent revision (13%), and 44 of the 391 women underwent revision (11%). The mean time from index surgery to revision was 7 years for both males and females. After controlling for confounding variables, the only variables found to be associated with revision surgery in patients with unilateral THA were VAS pain (hazard ratio [HR], 1.28; p < 0.001) and elevated cobalt metal ion levels (HR, 1.02; p < 0.001). Patients with bilateral arthroplasties with low HHS (HR, 0.96; p < 0.001) and high cobalt levels (HR, 1.02; p < 0.001) were at increased risk for revision. Moderate-to-severe ALTRs were identified in 48 of the 133 hips with MARS MRI (36%), 17 of which were in females (30% of females) and 31 in males (40% of males). The only variables found to be associated with the presence of moderate-to-severe ALTR were abduction angle (HR, 0.92; p = 0.004) and Corail AMT stem type (HR, 2.31; p = 0.012). Female gender did not influence the risk of revision or ALTR. Chromium concentrations were greater in female patients than males, while cobalt levels were similar between genders. Males reported higher HHS, EQ-5D and UCLA scores than females. Discussion and Conclusion. Both males and females with MoM THA implants should be followed with equal vigilance as gender does not appear to be associated with poor outcomes, such as revision surgery and presence of ALTR


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 12 - 12
1 May 2016
Al-Dirini R Taylor M O'Rourke D Huff D
Full Access

Introduction. Primary stability is essential for long-term performance of cementless femoral components. There is debate as to whether collars contribute to primary stability. The results from experimental studies and finite element (FE) analysis have been variable and contradictory. Subtle differences in performance are often swamped by variation between cadaveric specimens in vitro, whereas FE studies tend to be performed on a single femur. However, FE studies have the potential to make comparisons of implant designs within the same cohort of femurs, allowing for subtle performance differences to be identified if present. This study investigates the effect of a collar on primary stability of a femoral prosthesis across a representative cohort of femurs. Materials and Methods. FE models were generated from QCT scans of eight cadaveric femurs taken from the Melbourne Femur Collection (4 male and 4 female; BMI: 18.7 – 36.8 kg.m-2; age: 59 – 80 years) which were of joint replacement age. Heterogeneous bone material properties were assigned based on the CT greyscale information. Each femur was implanted with the collared and collarless version of Corail femoral stem (DePuy, Leeds, United Kingdom). The stems were sized and positioned so that the prosthesis filled the medullary canal with minimal gap between the prosthesis and the inner boundary of the cortical bone. The peak muscle and joint contact forces associated with level gait were applied and the distal femur was rigidly fixed. The forces were scaled based on the body weight for each subject. Micromotion, as well as microstrains at the bone-prosthesis interface were measured for each subject. Paired t-test was run to compare the micromotion and the microstrains measured for the collared and collarless prosthesis. Results. There were no significant differences in micromotion (p > 0.005) and microstrains (p » 0.005) between collared and collarless prostheses. The mean of the median micromotions for the collared and the collarless prostheses were 19.4 microns and 20.5 microns, respectively. The mean of the median equivalent strains at the bone-implant interface for the collared and the collarless prostheses were 828.5 microstrains and 824.3 microstrains, respectively. The mean percentage of the area at the contact interface that experienced equivalent strains lower than 2000 microstrains was 69.9% for the collared and 70.0% for the collarless designs. The mean percentage of the contact area at the bone-prosthesis interface that experience equivalent strains greater than 7000 microstrains, the yield strain, was only 9.9% for the collared and 5.7% for the collarless designs. Discussion and conclusions. There was considerable variation across the cohort of femurs, with a factor of two difference for both micromotion and interface strain While small differences were noted between the collared and collarless prostheses implanted in the same femur, these differences were minimal and were likely to have little affects on primary stability, at least for a level gait load case. More demanding load cases may result in greater differences between collared and collarless implants. The results suggest that the addition of a collar in routine cases may not enhance the primary stability of a cementless hip stem


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1654 - 1661
1 Dec 2020
Perelgut ME Polus JS Lanting BA Teeter MG

Aims

The direct anterior (DA) approach has been associated with rapid patient recovery after total hip arthroplasty (THA) but may be associated with more frequent femoral complications including implant loosening. The objective of this study was to determine whether the addition of a collar to the femoral stem affects implant migration, patient activity, and patient function following primary THA using the DA approach.

Methods

Patients were randomized to either a collared (n = 23) or collarless (n = 26) cementless femoral stem implanted using the DA approach. Canal fill ratio (CFR) was measured on the first postoperative radiographs. Patients underwent a supine radiostereometric analysis (RSA) exam postoperatively on the day of surgery and at two, four, six, 12, 26, and 52 weeks postoperatively. Patient-reported outcome measures (Western Ontario and McMaster Universities Osteoarthritis (WOMAC) Index, the 12-item Short Form Health Survey Mental and Physical Score, and University of California, Los Angeles (UCLA) Activity Score) were measured preoperatively and at each post-surgery clinic visit. Activity and function were also measured as the weekly average step count recorded by an activity tracker, and an instrumented timed up-and-go (TUG) test in clinic, respectively.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 39 - 39
1 Jan 2004
Chatelet J Setiey L
Full Access

Purpose: Exposure to polyethylene debris and bearing wear is a common feature of total hip prosthesis inserted with or without cement. Osteolysis depends on the number of particles involved and their size. This continuous series of total hip arthroplasties using a Corail prosthesis with 12 years follow-up was studied to assess the course of osteolysis around the prosthesis and the resistance of hydroxyapatite coated implants to the aggression of wear debris. Material and methods: One hundred fifteen patients underwent total hip arthroplasty in 1989 with a Corail prosthesis implanted by the same operator with a metal backed cup and a polyethylene insert. Mean age at implantation was 65 years. Review radiograms were available for 80 patients (38 women and 42 men). Twenty-seven patients had died, five answered a phone interview and three were lost to follow-up. The follow-up was 12 years and analysis was performed on the population with review data and x-rays. Results: There was no case with a loosened stem and none of the patients underwent revision. Twelve cups were however revised for loosening with granuloma. Polyethylene insert wear was seen in 62% of the cases. There was a relationship between the amount of wear debris and the extent of the gramulomas on the femur. These granulomas were basically observed in zones I and VII. Bone defects were curetted and filled with grafts for the 12 cup revisions. The cup bearing was changed in young patients. Good bone healing was a constant finding on follow-up x-rays. Discussion: Hydroxyapatite coated prostheses exhibit good long-term resistance to wear debris which causes osteolysis since none of the Corail femoral stems were destabilised. The granulomas remain localised in the proximal zone and do not descend along the stem or the cement as seen in cemented prostheses. The intimate contact between the recipient bone and the implant appears to form a barrier against migration of wear debris. It thus appears important to achieve good contact all along the stem and to use a totally hydroxyapatite coated implant. Conclusion: Total hip arthroplasty without cement is spared the problem of polyethylene wear debris, but debris must be limited to prevent osteolysis. This observation questions the long-term appropriateness of metal-backed cups with polyethylene inserts and suggests that low friction arthroplasty or use of a hard bearing couple (Cr-Co-Cr-Co or alumina-alumina) should be preferred


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1010 - 1017
1 Aug 2018
Jain S Magra M Dube B Veysi VT Whitwell GS Aderinto JB Emerton ME Stone MH Pandit HG

Aims

This study aimed to evaluate implant survival of reverse hybrid total hip arthroplasty (THA) at medium-term follow-up.

Patients and Methods

A consecutive series of 1082 THAs in 982 patients with mean follow-up of 7.9 years (5 to 11.3) is presented. Mean age was 69.2 years (21 to 94). Of these, 194 (17.9%) were in patients under 60 years, 663 (61.3%) in female patients and 348 (32.2%) performed by a trainee. Head size was 28 mm in 953 hips (88.1%) or 32 mm in 129 hips (11.9%). Survival analysis was performed and subgroups compared using log rank tests.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 779 - 786
1 Jul 2019
Lamb JN Baetz J Messer-Hannemann P Adekanmbi I van Duren BH Redmond A West RM Morlock MM Pandit HG

Aims

The aim of this study was to estimate the 90-day risk of revision for periprosthetic femoral fracture associated with design features of cementless femoral stems, and to investigate the effect of a collar on this risk using a biomechanical in vitro model.

Materials and Methods

A total of 337 647 primary total hip arthroplasties (THAs) from the United Kingdom National Joint Registry (NJR) were included in a multivariable survival and regression analysis to identify the adjusted hazard of revision for periprosthetic fracture following primary THA using a cementless stem. The effect of a collar in cementless THA on this risk was evaluated in an in vitro model using paired fresh frozen cadaveric femora.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 536 - 539
1 May 2019
Cassidy RS O hEireamhoin S Beverland DE

Aims

The aim of this retrospective audit was to determine the route of referral or presentation of patients requiring revision following primary total hip arthroplasty (THA).

Patients and Methods

A total of 4802 patients were implanted with an Orthopaedic Data Evaluation Panel (ODEP) 10A* cementless implant (Corail/Pinnacle) between 2005 and 2015; 80 patients with a mean age of 67.8 years (sd 10.8) underwent a subsequent revision. The primary outcome measure was route of referral for revision.


Bone & Joint 360
Vol. 6, Issue 2 | Pages 10 - 13
1 Apr 2017


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 33 - 41
1 Jan 2018
Matharu GS Hunt LP Murray DW Howard P Pandit HG Blom AW Bolland B Judge A

Aims

The aim of this study was to determine whether the rates of revision for metal-on-metal (MoM) total hip arthroplasties (THAs) with Pinnacle components varied according to the year of the initial operation, and compare these with the rates of revision for other designs of MoM THA.

Patients and Methods

Data from the National Joint Registry for England and Wales included 36 mm MoM THAs with Pinnacle acetabular components which were undertaken between 2003 and 2012 with follow-up for at least five years (n = 10 776) and a control group of other MoM THAs (n = 13 817). The effect of the year of the primary operation on all-cause rates of revision was assessed using Cox regression and interrupted time-series analysis.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1147 - 1152
1 Sep 2017
Lainiala O Reito A Jämsä P Eskelinen A

Aims

To determine whether there is any association between glomerular filtration rate (GFR) and blood cobalt (Co) and chromium (Cr) levels in patients with metal-on-metal (MoM) hip arthroplasty.

Patients and Methods

We identified 179 patients with a unilateral 36 mm diameter head as part of a stemmed Summit-Pinnacle MoM hip arthroplasty. GFR was calculated using the Modification of Diet in Renal Disease formula.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 94 - 99
1 Jan 2015
Grammatopoulos G Wilson HA Kendrick BJL Pulford EC Lippett J Deakin M Andrade AJ Kambouroglou G

National Institute of Clinical Excellence guidelines state that cemented stems with an Orthopaedic Data Evaluation Panel (ODEP) rating of > 3B should be used for hemiarthroplasty when treating an intracapsular fracture of the femoral neck. These recommendations are based on studies in which most, if not all stems, did not hold such a rating.

This case-control study compared the outcome of hemiarthroplasty using a cemented (Exeter) or uncemented (Corail) femoral stem. These are the two prostheses most commonly used in hip arthroplasty in the UK.

Data were obtained from two centres; most patients had undergone hemiarthroplasty using a cemented Exeter stem (n = 292/412). Patients were matched for all factors that have been shown to influence mortality after an intracapsular fracture of the neck of the femur. Outcome measures included: complications, re-operations and mortality rates at two, seven, 30 and 365 days post-operatively. Comparable outcomes for the two stems were seen.

There were more intra-operative complications in the uncemented group (13% vs 0%), but the cemented group had a greater mortality in the early post-operative period (n = 6). There was no overall difference in the rate of re-operation (5%) or death (365 days: 26%) between the two groups at any time post-operatively.

This study therefore supports the use of both cemented and uncemented stems of proven design, with an ODEP rating of 10A, in patients with an intracapsular fracture of the neck of the femur.

Cite this article: Bone Joint J 2015;97-B:94–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1574 - 1580
1 Dec 2007
Hallan G Lie SA Furnes O Engesaeter LB Vollset SE Havelin LI

Primary uncemented femoral stems reported to the Norwegian arthroplasty register between 1987 and 2005 were included in this prospective observational study. There were 11 516 hips (9679 patients) and 14 different designs of stem. Kaplan-Meier survival probabilities and Cox regression were used to analyse the data. With aseptic loosening as the end-point, all currently used designs performed excellently with survival of 96% to 100% at ten years. With the end-point as stem revision for any cause, the long-term results of the different designs varied from poor to excellent, with survival at 15 years ranging between 29% and 97%. Follow-up for longer than seven years was needed to identify some of the poorly-performing designs. There were differences between the stems; the Corail, used in 5456 hips, was the most frequently used stem with a survival of 97% at 15 years. Male gender was associated with an increased risk of revision of × 1.3 (95% confidence interval 1.05 to 1.52), but age and diagnosis had no influence on the results. Overall, modern uncemented femoral stems performed well. Moderate differences in survival between well-performing stems should be interpreted with caution since the differences may be caused by factors other than the stem itself


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 300 - 305
1 Mar 2015
Hill JC Diamond OJ O’Brien S Boldt JG Stevenson M Beverland DE

Ceramic-on-metal (CoM) is a relatively new bearing combination for total hip arthroplasty (THA) with few reported outcomes. A total of 287 CoM THAs were carried out in 271 patients (mean age 55.6 years (20 to 77), 150 THAs in female patients, 137 in male) under the care of a single surgeon between October 2007 and October 2009. With the issues surrounding metal-on-metal bearings the decision was taken to review these patients between March and November 2011, at a mean follow-up of 34 months (23 to 45) and to record pain, outcome scores, radiological analysis and blood ion levels. The mean Oxford Hip Score was 19.2 (12 to 53), 254 patients with 268 hips (95%) had mild/very mild/no pain, the mean angle of inclination of the acetabular component was 44.8o (28o to 63o), 82 stems (29%) had evidence of radiolucent lines of > 1 mm in at least one Gruen zone and the median levels of cobalt and chromium ions in the blood were 0.83 μg/L (0.24 μg/L to 27.56 μg/L) and 0.78 μg/L (0.21 μg/L to 8.84 μg/L), respectively. The five-year survival rate is 96.9% (95% confidence interval 94.7% to 99%).

Due to the presence of radiolucent lines and the higher than expected levels of metal ions in the blood, we would not recommend the use of CoM THA without further long-term follow-up. We plan to monitor all these patients regularly.

Cite this article: Bone Joint J 2015;97-B:300–5.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1538 - 1543
1 Nov 2013
Kendrick BJL Wilson HA Lippett JE McAndrew AR Andrade AJMD

The National Institute for Health and Clinical Excellence (NICE) guidelines from 2011 recommend the use of cemented hemi-arthroplasty for appropriate patients with an intracapsular hip fracture. In our institution all patients who were admitted with an intracapsular hip fracture and were suitable for a hemi-arthroplasty between April 2010 and July 2012 received an uncemented prosthesis according to our established departmental routine practice. A retrospective analysis of outcome was performed to establish whether the continued use of an uncemented stem was justified. Patient, surgical and outcome data were collected on the National Hip Fracture database. A total of 306 patients received a Cathcart modular head on a Corail uncemented stem as a hemi-arthroplasty. The mean age of the patients was 83.3 years (sd 7.56; 46.6 to 94) and 216 (70.6%) were women. The mortality rate at 30 days was 5.8%. A total of 46.5% of patients returned to their own home by 30 days, which increased to 73.2% by 120 days. The implant used as a hemi-arthroplasty for intracapsular hip fracture provided satisfactory results, with a good rate of return to pre-injury place of residence and an acceptable mortality rate. Surgery should be performed by those who are familiar with the design of the stem and understand what is required for successful implantation.

Cite this article: Bone Joint J 2013;95-B:1538–43.


The Bone & Joint Journal
Vol. 99-B, Issue 1_Supple_A | Pages 50 - 59
1 Jan 2017
Carli AV Negus JJ Haddad FS

Aims

Periprosthetic femoral fractures (PFF) following total hip arthroplasty (THA) are devastating complications that are associated with functional limitations and increased overall mortality. Although cementless implants have been associated with an increased risk of PFF, the precise contribution of implant geometry and design on the risk of both intra-operative and post-operative PFF remains poorly investigated. A systematic review was performed to aggregate all of the PFF literature with specific attention to the femoral implant used.

Patients and Methods

A systematic search strategy of several journal databases and recent proceedings from the American Academy of Orthopaedic Surgeons was performed. Clinical articles were included for analysis if sufficient implant description was provided. All articles were reviewed by two reviewers. A review of fundamental investigations of implant load-to-failure was performed, with the intent of identifying similar conclusions from the clinical and fundamental literature.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1011 - 1016
1 Aug 2011
Langton DJ Jameson SS Joyce TJ Gandhi JN Sidaginamale R Mereddy P Lord J Nargol AVF

There is widespread concern regarding the incidence of adverse soft-tissue reactions after metal-on-metal (MoM) hip replacement. Recent National Joint Registry data have shown clear differences in the rates of failure of different designs of hip resurfacing. Our aim was to update the failure rates related to metal debris for the Articular Surface Replacement (ASR). A total of 505 of these were implanted.

Kaplan-Meier analysis showed a failure rate of 25% at six years for the ASR resurfacing and of 48.8% for the ASR total hip replacement (THR). Of 257 patients with a minimum follow-up of two years, 67 (26.1%) had a serum cobalt concentration which was greater than 7 μg/l. Co-ordinate measuring machine analysis of revised components showed that all patients suffering adverse tissue reactions in the resurfacing group had abnormal wear of the bearing surfaces. Six THR patients had relatively low rates of articular wear, but were found to have considerable damage at the trunion-taper interface. Our results suggest that wear at the modular junction is an important factor in the development of adverse tissue reactions after implantation of a large-diameter MoM THR.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 445 - 450
1 Apr 2017
Marsh AG Nisar A El Refai M Patil S Meek RMD

Aims

The purpose of this study was to evaluate whether an innovative templating technique could predict the need for acetabular augmentation during primary total hip arthroplasty for patients with dysplastic hips.

Patients and Methods

We developed a simple templating technique to estimate acetabular component coverage at total hip arthroplasty, the True Cup: False Cup (TC:FC) ratio. We reviewed all patients with dysplastic hips who underwent primary total hip arthroplasty between 2005 and 2012. Traditional radiological methods of assessing the degree of acetabular dysplasia (Sharp’s angle, Tönnis angle, centre-edge angle) as well as the TC:FC ratio were measured from the pre-operative radiographs. A comparison of augmented and non-augmented hips was undertaken to determine any difference in pre-operative radiological indices between the two cohorts. The intra- and inter-observer reliability for all radiological indices used in the study were also calculated.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 595 - 602
1 May 2015
McCalden RW Korczak A Somerville L Yuan X Naudie DD

This was a randomised controlled trial studying the safety of a new short metaphyseal fixation (SMF) stem. We hypothesised that it would have similar early clinical results and micromovement to those of a standard-length tapered Synergy metaphyseal fixation stem. Using radiostereometric analysis (RSA) we compared the two stems in 43 patients. A short metaphyseal fixation stem was used in 22 patients and a Synergy stem in 21 patients. No difference was found in the clinical outcomes pre- or post-operatively between groups. RSA showed no significant differences two years post-operatively in mean micromovement between the two stems (except for varus/valgus tilt at p = 0.05) (subsidence 0.94 mm (sd 1.71) vs 0.32 mm (sd 0.45), p = 0.66; rotation 0.96° (sd 1.49) vs 1.41° (sd 2.95), p = 0.88; and total migration 1.09 mm (sd 1.74) vs 0.73 mm (sd 0.72), p = 0.51). A few stems (four SMF and three Synergy) had initial migration > 1.0 mm but stabilised by three to six months, with the exception of one SMF stem which required revision three years post-operatively. For most stems, total micromovement was very low at two years (subsidence < 0.5 mm, rotation < 1.0°, total migration < 0.5 mm), which was consistent with osseous ingrowth. The small sample makes it difficult to confirm the universal applicability of or elucidate the potential contraindications to the use of this particular new design of stem.

Cite this article: Bone Joint J 2015; 97-B:595–602.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 762 - 770
1 Jun 2015
Pennington MW Grieve R van der Meulen JH

There is little evidence on the cost effectiveness of different brands of hip prostheses. We compared lifetime cost effectiveness of frequently used brands within types of prosthesis including cemented (Exeter V40 Contemporary, Exeter V40 Duration and Exeter V40 Elite Plus Ogee), cementless (Corail Pinnacle, Accolade Trident, and Taperloc Exceed) and hybrid (Exeter V40 Trilogy, Exeter V40 Trident, and CPT Trilogy). We used data from three linked English national databases to estimate the lifetime risk of revision, quality-adjusted life years (QALYs) and cost.

For women with osteoarthritis aged 70 years, the Exeter V40 Elite Plus Ogee had the lowest risk of revision (5.9% revision risk, 9.0 QALYs) and the CPT Trilogy had the highest QALYs (10.9% revision risk, 9.3 QALYs). Compared with the Corail Pinnacle (9.3% revision risk, 9.22 QALYs), the most commonly used brand, and assuming a willingness-to-pay of £20 000 per QALY gain, the CPT Trilogy is most cost effective, with an incremental net monetary benefit of £876. Differences in cost effectiveness between the hybrid CPT Trilogy and Exeter V40 Trident and the cementless Corail Pinnacle and Taperloc Exceed were small, and a cautious interpretation is required, given the limitations of the available information.

However, it is unlikely that cemented brands are among the most cost effective. Similar patterns of results were observed for men and other ages. The gain in quality of life after total hip arthroplasty, rather than the risk of revision, was the main driver of cost effectiveness.

Cite this article: Bone Joint J 2015;97-B:762–70.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1610 - 1616
1 Dec 2013
Epinette J Asencio G Essig J Llagonne B Nourissat C

We report a multicentre prospective consecutive study assessing the long-term outcome of the proximally hydroxyapatite (HA)-coated ABG II monobloc femoral component in a series of 1148 hips in 1053 patients with a mean age at surgery of 64.77 years (22 to 80) at a mean follow-up of 10.84 years (10 to 15.25). At latest follow-up, the mean total Harris hip score was 94.7 points (sd; 6.87; 49 to 100), and the mean Merle d’Aubigné–Postel score was 17.6 points (sd 1.12; 7 to 18). The mean total Engh radiological score score was 21.54 (sd 5.77; 3.5 to 27), with 95.81% of ‘confirmed ingrowth’, according to Engh’s classification. With aseptic loosening or pain as endpoints, three AGB II stems (0.26%) failed, giving a 99.7% survival rate (se 0.002; 95% confidence interval (CI) 0.994 to 1) at 14 years’ follow-up. The survival of patients ≤ 50 years of age (99.0% (se 0.011; 95% CI 0.969 to 1)) did not differ significantly from those of patients aged > 50 years (99.8% (se 0.002; 95% CI 0.994 to 1)). This study confirmed the excellent long-term results currently achieved with the ABG II proximally HA-coated monobloc stem.

Cite this article: Bone Joint J 2013;95-B:1610–16.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 160 - 165
1 Feb 2013
McDonnell SM Boyce G Baré J Young D Shimmin AJ

Noise generation has been reported with ceramic-on-ceramic articulations in total hip replacement (THR). This study evaluated 208 consecutive Delta Motion THRs at a mean follow-up of 21 months (12 to 35). There were 141 women and 67 men with a mean age of 59 years (22 to 84). Patients were reviewed clinically and radiologically, and the incidence of noise was determined using a newly described assessment method. Noise production was examined against range of movement, ligamentous laxity, patient-reported outcome scores, activity level and orientation of the acetabular component. There were 143 silent hips (69%), 22 (11%) with noises other than squeaking, 17 (8%) with unreproducible squeaking and 26 (13%) with reproducible squeaking. Hips with reproducible squeaking had a greater mean range of movement (p < 0.001) and mean ligament laxity (p = 0.004), smaller median head size (p = 0.01) and decreased mean acetabular component inclination (p = 0.02) and anteversion angle (p = 0.02) compared with the other groups. There was no relationship between squeaking and age (p = 0.13), height (p = 0.263), weight (p = 0.333), body mass index (p = 0.643), gender (p = 0.07) or patient outcome score (p = 0.422). There were no revisions during follow-up. Despite the surprisingly high incidence of squeaking, all patients remain satisfied with their hip replacement.

Cite this article: Bone Joint J 2013;95-B:160–5.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1113 - 1119
1 Aug 2012
Gjertsen J Lie SA Vinje T Engesæter LB Hallan G Matre K Furnes O

Using data from the Norwegian Hip Fracture Register, 8639 cemented and 2477 uncemented primary hemiarthroplasties for displaced fractures of the femoral neck in patients aged > 70 years were included in a prospective observational study. A total of 218 re-operations were performed after cemented and 128 after uncemented procedures. Survival of the hemiarthroplasties was calculated using the Kaplan-Meier method and hazard rate ratios (HRR) for revision were calculated using Cox regression analyses. At five years the implant survival was 97% (95% confidence interval (CI) 97 to 97) for cemented and 91% (95% CI 87 to 94) for uncemented hemiarthroplasties. Uncemented hemiarthroplasties had a 2.1 times increased risk of revision compared with cemented prostheses (95% confidence interval 1.7 to 2.6, p < 0.001). The increased risk was mainly caused by revisions for peri-prosthetic fracture (HRR = 17), aseptic loosening (HRR = 17), haematoma formation (HRR = 5.3), superficial infection (HRR = 4.6) and dislocation (HRR = 1.8). More intra-operative complications, including intra-operative death, were reported for the cemented hemiarthroplasties. However, in a time-dependent analysis, the HRR for re-operation in both groups increased as follow-up increased.

This study showed that the risk for revision was higher for uncemented than for cemented hemiarthroplasties.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 747 - 757
1 Jun 2013
Jameson SS Baker PN Mason J Rymaszewska M Gregg PJ Deehan DJ Reed MR

The popularity of cementless total hip replacement (THR) has surpassed cemented THR in England and Wales. This retrospective cohort study records survival time to revision following primary cementless THR with the most common combination (accounting for almost a third of all cementless THRs), and explores risk factors independently associated with failure, using data from the National Joint Registry for England and Wales. Patients with osteoarthritis who had a DePuy Corail/Pinnacle THR implanted between the establishment of the registry in 2003 and 31 December 2010 were included within analyses. There were 35 386 procedures. Cox proportional hazard models were used to analyse the extent to which the risk of revision was related to patient, surgeon and implant covariates. The overall rate of revision at five years was 2.4% (99% confidence interval 2.02 to 2.79). In the final adjusted model, we found that the risk of revision was significantly higher in patients receiving metal-on-metal (MoM: hazard ratio (HR) 1.93, p < 0.001) and ceramic-on-ceramic bearings (CoC: HR 1.55, p = 0.003) compared with the best performing bearing (metal-on-polyethylene). The risk of revision was also greater for smaller femoral stems (sizes 8 to 10: HR 1.82, p < 0.001) compared with mid-range sizes. In a secondary analysis of only patients where body mass index (BMI) data were available (n = 17 166), BMI ≥ 30 kg/m2 significantly increased the risk of revision (HR 1.55, p = 0.002). The influence of the bearing on the risk of revision remained significant (MoM: HR 2.19, p < 0.001; CoC: HR 2.09, p = 0.001). The risk of revision was independent of age, gender, head size and offset, shell, liner and stem type, and surgeon characteristics.

We found significant differences in failure between bearing surfaces and femoral stem size after adjustment for a range of covariates in a large cohort of single-brand cementless THRs. In this study of procedures performed since 2003, hard bearings had significantly higher rates of revision, but we found no evidence that head size had an effect. Patient characteristics, such as BMI and American Society of Anesthesiologists grade, also influence the survival of cementless components.

Cite this article: Bone Joint J 2013;95-B:747–57.


Bone & Joint Research
Vol. 1, Issue 4 | Pages 56 - 63
1 Apr 2012
Langton DJ Sidaginamale R Lord JK Nargol AVF Joyce TJ

Objectives

An ongoing prospective study to investigate failing metal-on-metal hip prostheses was commenced at our centre in 2008. We report on the results of the analysis of the first consecutive 126 failed mated total hip prostheses from a single manufacturer.

Methods

Analysis was carried out using highly accurate coordinate measuring to calculate volumetric and linear rates of the articular bearing surfaces and also the surfaces of the taper junctions. The relationship between taper wear rates and a number of variables, including bearing diameter and orientation of the acetabular component, was investigated.