Understanding lumbar facet joint involvement and biomechanical changes post spinal fusion is limited. This study aimed to establish an in vitro model assessing mechanical effects of fusion on human lumbar facet joints, employing synchronized motion, pressure, and stiffness analysis. Seven human lumbar spinal units (age 54 to 92, ethics 15/YH/0096) underwent fusion via a partial nucleotomy model mimicking a lateral cage approach with PMMA cement injection. Mechanical testing pre and post-fusion included measuring compressive displacement and load, local motion capture, and pressure mapping at the facet joints. pQCT imaging (82 microns isotropic) was carried out at each stage to assess the integrity of the vertebral endplates and quantify the amount of cement injected. Before fusion, relative facet joint displacement (6.5 ± 4.1 mm) at maximum load (1.1 kN) exceeded crosshead displacement (3.9 ± 1.5 mm), with loads transferred across both facet joints. After fusion, facet displacement (2.0 ± 1.2 mm) reduced compared to pre-fusion, as was the crosshead displacement (2.2 ± 0.6 mm). Post-fusion loads (71.4 ± 73.2 N) transferred were reduced compared to pre-fusion levels (194.5 ± 125.4 N). Analysis of CT images showed no endplate damage post-fusion, whilst the IVD tissue: cement volume ratio did not correlate with the post-fusion behaviour of the specimens.Objectives
Methods and Results
Osteoporosis can cause significant disability and cost to health services globally. We aim to compare risk fractures for both osteoporosis and fractures at the L1-L4 vertebrae (LV) and the neck of femurs (NOFs) in patients referred for DEXA scan in the North-West of England. Data was obtained from 31546 patients referred for DEXA scan in the North-West of England between 2004 and 2011. Demographic data was retrospectively analysed using STATA, utilising chi-squared and t-tests. Logistical models were used to report odds ratios for risk factors included in the FRAX tool looking for differences between osteoporosis and fracture risk at the LV and NOFs. In a study involving 2530 cases of LV fractures and 1363 of NOF fractures, age was significantly linked to fractures and osteoporosis at both sites, with a higher risk of osteoporosis at NOFs compared to LV. Height provided protection against fractures and osteoporosis at both sites, with a more pronounced protective effect against osteoporosis at NOFs. Weight was more protective for NOF fractures, while smoking increased osteoporosis risk with no site-specific difference. Steroids were unexpectedly protective for fractures at both sites, with no significant difference, while alcohol consumption was protective against osteoporosis at both sites and associated with increased LV fracture risk. Rheumatoid arthritis increased osteoporosis risk in NOFs and implied a higher fracture risk, though not statistically significant compared to LV. Results summarised in Table 1. Our study reveals that established osteoporosis and fracture risk factors impact distinct bony sites differently. Age and rheumatoid arthritis increase osteoporosis risk more at NOFs than LV, while height and steroids provide greater protection at NOFs. Height significantly protects LV fractures, with alcohol predicting them. Further research is needed to explore risk factors’ impact on additional bony sites and understand the observed differences’ pathophysiology. For any figures or tables, please contact the authors directly.
Up to 19% of patients who undergo surgery for an acute hip fracture are readmitted to the hospital within three months of the index operation. We aimed to identify risk factors for unplanned clinic attendance, readmission, and mortality within the first 12 months postoperatively and subsequently determine if there is a role for routine follow-up. Patients greater than 65 years old who underwent hip hemiarthroplasty using an uncemented Thompson implant for treatment of a traumatic non-pathological hip fracture were identified from a prospectively maintained database at a single institution between August 2007 and February 2011. Patient demographics, comorbidities, place of residence, mobility status, unplanned attendance to an orthopaedic clinic with symptoms relating to the respective limb, readmission, and mortality were recorded.Abstract
Objectives
Methods
Iliopsoas pathology is a relatively uncommon cause of pain following total hip arthroplasty (THA), typically presenting with symptoms of groin pain on active flexion and/or extension of the hip. A variety of conservative and surgical treatment options have been reported. In this retrospective cohort study, we report the incidence of iliopsoas pathology and treatment outcomes. A retrospective review of 1,000 patients who underwent THA over a five-year period was conducted, to determine the incidence of patients diagnosed with iliopsoas pathology. Outcome following non-surgical and surgical management was assessed.Aims
Methods
Hip fractures in young adults are rare but represent an important cohort of patients, of which relatively limited data exists. The aim of this study was to evaluate this distinct subgroup of hip fractures from an epidemiological perspective and assess their subsequent outcomes. Patients aged 18–50 were identified across an 8 year period from a total of 5326 hip fractures. 46 hip fractures met the inclusion criteria and a retrospective case series analysis was conducted. 25/46 (54%) of fractures were intracapsular and 21/46 (46%) were extracapsular. Only 15/46 (33%) of fractures were sustained from a high energy mechanism and 31/46 (67%) low energy. The low energy cohort was significantly more comorbid with a mean Elixhauser comorbidity score of 1.5 compared to the high energy cohort 0.3 (p<0.0005, unpaired t-test). Alcohol excess was the most prevalent comorbidity present in 24% of patients and was a positive predictor in complication (p=0.006, binary regression). Failure of fixation (non-union/avascular necrosis) in displaced intracapsular fractures sustained following low energy trauma managed by internal fixation 5/11 (45%) was markedly higher than the high energy cohort 0/6 (0%). 5 year mortality was 9% for all hip fractures, six times higher than an aged matched cohort of non-hip fractures (p=0.007, Wilcoxon test). Representing only 0.86% of all hip fractures in the study period, hip fractures in young adults are rare. A clear sub-division of patients is observed between patients with a low and high energy mechanism, both in terms of level of comorbidity and surgical outcome.
We evaluated an operative technique, described
by the Exeter Hip Unit, to assist accurate introduction of the femoral
component. We assessed whether it led to a reduction in the rate
of leg-length discrepancy after total hip arthroplasty (THA). A total of 100 patients undergoing THA were studied retrospectively;
50 were undertaken using the test method and 50 using conventional
methods as a control group. The groups were matched with respect
to patient demographics and the grade of surgeon. Three observers
measured the depth of placement of the femoral component on post-operative
radiographs and measured the length of the legs. There was a strong correlation between the depth of insertion
of the femoral component and the templated depth in the test group
(R = 0.92), suggesting accuracy of the technique. The mean leg-length
discrepancy was 5.1 mm (0.6 to 21.4) pre-operatively and 1.3 mm
(0.2 to 9.3) post-operatively. There was no difference between Consultants
and Registrars as primary surgeons. Agreement between the templated
and post-operative depth of insertion was associated with reduced
post-operative leg-length discrepancy. The intra-class coefficient
was R ≥ 0.88 for all measurements, indicating high observer agreement.
The post-operative leg-length discrepancy was significantly lower
in the test group (1.3 mm) compared with the control group (6.3
mm, p <
0.001). The Exeter technique is reproducible and leads to a lower incidence
of leg-length discrepancy after THA. Cite this article:
The aim of our study was to assess the outcome of caudal epidural injection for patients with low back pain in relation to fatty infiltration of spinal muscle. This is a prospective study. The spinal muscles were graded on sagittal section T1 MRI at the lower border of lumber 4 vertebra from 3 to 12 depending on the severity of fatty infiltration. The outcome of the intervention was assessed by improvement in pre and post intervention oswestry disability index score as well as visual analog pain score. Patients with significant fatty changes don't respond well to the caudal epidural injection.
Early stabilization has the potential to expedite early return to function and reduce hospital stay thus reducing cost to health care. A clinical audit was performed to test the hypothesis that early surgical stabilization lowers the rate of soft tissue complications and is not influenced by choice of distal fibular implants used for stabilization of ankle fractures. All surgically treated adult patients with isolated unstable ankle fracture were included from April 2012 to April 2013 at a MTC in UK. Patients with poly-trauma were excluded. All patients underwent a standard surgical protocol: aim for early definitive surgical fixation (ORIF) within 24 hours however if significantly swollen than temporary stabilization with an external fixation followed by a staged definitive fixation.Introduction:
Methods:
The ideal treatment for traumatic anterior dislocation
of the shoulder in the skeletally immature patient is controversial.
The aim of this study is to evaluate the outcomes after either conservative
and/or surgical treatment using the Latarjet technique. A retrospective
series of 49 out of 80 patients were reviewed. We found no significant differences
between either treatment method regarding functional scores and
pain levels. Although not statistically significant, post-surgical
patients showed better signs of shoulder stability than others who
have a higher rate of recurrence. Further, 92% of the post-surgical
group had returned to the same level of activity Cite this article:
There has been a recent surge in the interest of the role of vitamin D in chronic musculoskeletal pain however there are limited studies that have investigated the link of vitamin D hypovitaminosis with low back pain. The aim of our study was to determine the prevalence of low vitamin D levels in patients who present with low back pain in an outpatient setting in the UK. Data was collected retrospectively from computerised databases of all patients who presented with low back pain from a single spinal consultant's outpatient clinic and have had serum levels of 25-hydroxycholecalciferol (25-OH vitamin D) requested. Data of these patients were collected from hospital electronic and paper records and analysed against their serum 25-OH vitamin D levels.Introduction
Methods
Leg length discrepancy (LLD) can adversely affect functional outcome and patient satisfaction after total hip arthroplasty. We describe a novel intraoperative technique for femoral component insertion. We aimed to determine if this technique resulted in the desired femoral placement, as templated, and if this was associated with a reduced LLD. A series of fifty consecutive primary total hip replacements were studied. Preoperative digital templating was performed on standardised PA radiographs of the hips by the senior surgeon. The preoperative LLD was calculated and the distance from the superior tip of the greater trochanter to the predicted shoulder of the stem was calculated (GT-S). Intraoperatively, this length was marked on the rasp handle and the stem inserted to the predetermined level by the surgeon. This level corresponded to the tip of the greater trochanter and formed a continuous line to the mark on the rasp handle. Three independent blinded observers measured the GT-S on the postoperative radiographs. We assessed the relationship between the senior author's GT-S (preoperative) and the observers' GT-S (postoperative) using a Person correlation. The observers also measured the preoperative and postoperative LLD, and the inter-observer variability was calculated as the intra-class correlation coefficient. There was a strong correlation of preoperative and postoperative GT-S (R=0.87), suggesting that the stem was inserted as planned. The mean preoperative and postoperative LLD were −4.3 mm (−21.4–4) and −0.9 mm (−9.8–8.6), respectively (p<0.001). This technique consistently minimised LLD in this series. This technique is quick, non-invasive and does not require supplementary equipment.
The advantages of metal on metal (MOM) hip replacement are decreased wear rate, preservation of bone stock, anatomical restoration and enhanced stability. Large amounts of metal wear particles and metal ions are released which may induce adverse reactions including local soft tissue toxicity, hypersensitivity reactions, bone loss and risk of carcinogenesis. Aseptic loosening can be the result of a peri prosthetic osteolysis generated as a result of a biological response to particulate wear debris. Our aim in this study was to determine whether a steeply inclined acetabular component would give rise to a higher concentration of metal ions. Between April 2003 and June 2006, 22 patients had MOM hip replacement for osteoarthritis by a single Surgeon. There were 12 male and 10 female patients. The average age at the time of surgery was 56 years (Range: 44–69 years). We divided the 22 patients into 2 groups, one group (A) of 11 patients with the acetabular inclination angle more than 50 degrees and the other group (B) of 11 patients with the angle less than 50 degrees. The inclination of the acetabular cup was measured using a standard AP radiograph of the pelvis. The patients had metal ion levels (blood chromium and serum cobalt) measured at an average follow up of 3.2 years (Range 2.4 to 5 years).Introduction
Patients and methods
The advantages of large diameter metal on metal total hip arthroplasty (MoM THA) and hip resurfacing arthroplasty are decreased wear rate, preservation of bone stock, anatomical restoration and enhanced stability. Large amounts of metal wear particles and metal ions are released which may induce adverse reactions including local soft tissue toxicity, hypersensitivity reactions, bone loss and risk of carcinogenesis. Aseptic loosening can be the result of a peri-prosthetic osteolysis generated as a result of a biological response to particulate wear debris. No reports in the literature exist as to whether circulating levels of Chromium (Cr) and Cobalt (Co) decrease upon removal of a symptomatic large diameter MoM implant or whether levels remain high due to the effect of metal ions debris left behind in the soft tissues after revision surgery. Between June 2006 and June 2009 we undertook 44 revision surgeries of both large head MoM THAs (femoral head diameter 38mm) and metal-on-metal hip resurfacings for suspected metallosis. Mean time from original implant to revision was 4 years, 8 months (1yr 4mo–7yr 9mo). The mean follow up evaluation was 2 years and 2 months (1yr 2mo–4 years). Blood samples were taken for whole blood Cr and serum Co according to a recognised protocol and compared with reference levels indicated by the Medicines and Healthcare Regulatory Agency recommendation of less than 7ppb for Cr (130nM/L) and Co (119nM/L).INTRODUCTION
PATIENTS AND METHODS
Bioreactors used in tissue engineering are mostly batch-fed with media added and removed periodically. Continuous flow bioreactors help increase ECM accumulation and cell proliferation, due to continuous flow of fresh media, thus, maintaining a steady extracellular nutrient environment. In previous work, we found chondrocytes cultured in continuous flow bioreactors with 20mM HEPES, accumulated considerably more matrix than static cultures. Hence, the objective of this study is to determine if NaHCO3 helps maintain a more physiological extracellular pH in the bioreactor, thus, enhancing ECM accumulation. Cartilaginous tissue constructs were generated from isolated chondrocytes harvested from the metacarpal joints of 12-18 month old calves. Cells were seeded in high-density 3D cultures (2 million cells/construct). Constructs were cultivated in a continuous flow bioreactor, with and without 14 mM NaHCO3 supplemented media, for 5 weeks, at 37 degrees Celsius, 95% relative humidity and 5% CO2. After 5 weeks of culture the tissue weight, thickness, pH and ECM deposition were determined. From the results obtained (Table 1), it is evident that chondrocytes cultured in the continuous flow bioreactor with 14mM NaHCO3 and 20mM HEPES, proliferated more extensively and produced more ECM than chondrocytes cultured in only 20mM HEPES. Additionally, the NaHCO3 constructs accumulated ECM in both the vertical (thickness) and horizontal (outgrowth) planes. The question then arises, are the effects mediated by improved buffering, or by addition of NaHCO3 itself. There was a significant difference between the pH of media with (pH 7.41) and without NaHCO3 (pH 6.95) supplementation, with no exposure to cells or tissue; when allowed to equilibrate with 5% CO2 at 37 degrees Celsius. However, there was little difference between the media after exposure to cells; after five weeks of culture in the bioreactor (Table 1). Thus, in the bioreactor with bicarbonate present, because of increased cell number and activity, the pH fell 0.54 pH units during the 7 hour residence time in comparison to the bioreactor with no bicarbonate supplementation. With no NaHCO3 supplementation, the extracellular pH of the medium fed to the cells was never above pH 7.0 (Table 1); low pH could account, at least in part, for lower ECM and cell numbers.
In revision hip surgery, Type IIIB femurs have presented the greatest historical challenge to achieving stable fixation and osseous integration. This study evaluated the intermediate term outcome of a modular, tapered, distal fixation revision femoral component used in a consecutive revision hip series with special attention to its performance in the defective Type IIIB femur. Between February 2002 and January 2005, 51 consecutive revision hip arthroplasties were performed using modular, tapered, distal fixation femoral components. The femoral defects at the time of revision surgery were classified using a system previously described by Paprosky. The most recent radiographs were reviewed and clinic notes examined to assess femoral component stability.Purpose
Methods
Patients with peripheral primary bone tumours are often identified and referred at an early stage to a regional tumour service according to established guidelines. In patients with primary bone tumours of the spine, however, the definitive management or outcome of such patients is being prejudiced by preliminary intervention from non-specialist services prior to their referral. Objective: To audit the standards of management of patients with primary bone tumours of the spine referred to a regional tumour service. Retrospective review of case notes and radiology. Subjects: Patients with primary bone tumour of the spine managed at the Orthopaedic Spine Unit with the Regional Bone Tumour Service in Newcastle Upon Tyne Hospitals NHS Trust. Referral to tumour service, prior intervention, operative treatment, survival, factors affecting definitive management 31 of 39 (16 benign, 23 malignant) patients were initially referred from primary care to services These tumours present complex issues regarding their definitive management to optimise outcome. Closer links between departments are required to enable the multidisciplinary management of primary bone tumours of the spine. Prior surgical intervention may compromise cure. Those involved in their management should be encouraged to liaise with their regional bone tumour service to improve outcome.
The mean age of the patients was 11.04 years (range between 4–16). Mean follow up time for the patients after they had undergone the procedure was 16.2 months (range 3 – 34). The Mean correction achieved − 21.52 degrees (range 5 – 40). Mean correction per month − 2.05 degrees. A paired ‘t’ test showed the correction was found to be highly statistically significant (p value <
0.001).
An online survey has been carried out to evaluate the compliance with the OCAP learning tools, and the availability of clinical experience to early years’ trainees in Trauma and Orthopaedics in 2007–8. Three surveys were planned over the year, and we present the results from the first two surveys. Over the initial eight month period, 335 trainees in Trauma and Orthopaedic posts responded. There was considerable variation in the proportion of responses from different deaneries, and it was felt this reflected differences in the use of the two logbooks available (FHI or ISCP). Respondents were FTSTAs (50%), ST1s (11%) and ST2s (29%). The respondents reported their operative experience was poor with low numbers of index procedures – the median values being 2 DHS, 1 Hemiarthroplasty and 0 for Ankle ORIFs performed as the lead surgeon in the first 4 months, rising to 3, 1 and 1 respectively in the second. As an assistant the numbers were 3, 4 and 3. FTSTAs had done more procedures as lead surgeon. It is not clear whether this reflects motivation, or whether they are trainees who were unable to secure training posts due to seniority and were already more experienced. Many posts were entirely ward based. Improvements in meetings with Assigned Educational Supervisors were noted, as was the use of the learning agreements, and with registration rates with the ISCP. There was considerable variation between posts, hospitals and deaneries, and a tool was developed to summarise this data to be post-, trainee-, and duration-specific. Summaries of each post were distributed to Training Program Directors, Heads of School, and the SAC. Although some improvement has occurred, further rounds of the survey are necessary to ensure that this continues. The next round will commence in September 2008 to complete twelve months of data.
There are no long-term published results on the survival of a third-generation cemented total shoulder replacement. We describe a clinical and radiological study of the Aequalis total shoulder replacement for a minimum of ten years. Between September 1996 and May 1998, 39 consecutive patients underwent a primary cemented total shoulder replacement using this prosthesis. Data were collected prospectively on all patients each year, for a minimum of ten years, or until death or failure of the prosthesis. At a follow-up of at least ten years, 12 patients had died with the prosthesis intact and two had emigrated, leaving 25 available for clinical review. Of these, 13 had rheumatoid arthritis and 12 osteoarthritis. One refused radiological review leaving 24 with fresh radiographs. Survivorship at ten years was 100% for the humeral component and 92% for the glenoid component. The incidence of lucent lines was low. No humeral component was thought to be at risk and only two glenoid components. The osteoarthritic group gained a mean 65° in forward flexion and their Constant score improved by a mean 41.4 points (13 to 55). The rheumatoid group gained a mean of 24° in flexion and their Constant score improved by 29.4 points. This difference may have been due to failure of the rotator cuff in 75% of the patients with rheumatoid arthritis. Thus a third-generation total shoulder replacement gives an excellent result in patients with osteoarthritis and an intact rotator cuff. Patients with rheumatoid arthritis have a 75% risk of failure of the rotator cuff at ten years.
This is a prospective study to determine if we could identify patients who may benefit from preoperative catheterisation in lower limb arthroplasty. 211 consecutive patients undergoing total hip and knee arthroplasty were recruited. There were 131 female (62%) and 80 male (32%), the mean age (+−1 S.D.) was 68+−12 years old. Patients’ demographic details and pre-operative urinary symptoms were recorded. Previous urological surgery and past history of urinary catherisation were also documented. The anaesthetist who was blinded from the study selected the type of anaesthesia and the post-operative analgesia regime. All patients were required to produce mid-stream urine sample before surgery and at post-operation. Urine tract infection was confirmed on a positive microbiological culture. Regression analysis was used to assess various co-variables to identify the high-risk groups. 35 female (56%) and 27 male (44%) were catheterised, the mean age (+−1 S.D.) was 72+/−14 years old. The frequency of catheterisation was unrelated to the surgical procedure, the type of anaesthesia or the postoperative pain control regime. Age over 65 years old and nocturia were significant indicators for urinary catheterisation (p<
0.05). Patients with urinary incontinence and nocturia were strong determinant for urinary catheterisation (p<
0.03). Males over the age 65 years with a past history of urinary catheterisation (p=0.037) were more likely to be catheterised than females of the same group (p=0.947). This has become more evidential if patients have coexisting urinary incontinence and nocturia (p=0.005). Females over the age of 65 years with urinary incontinence were also significant (p=0.013). The sensitivity for urinary catheterisation in patients over the age of 65 years with previous history of catheterisation, urinary incontinence or nocturia was 89.7%. This group of patients would benefit from pre-operative urinary catheterisation.
While the early period of distraction osteogenesis has been extensively investigated, there are very few data describing the long-term morphology of the regenerate. We performed magnetic resonance scans in ten adults (men age 35+− 11 yr), seven of whom had bone transport for an iatrogenic osseous defect while further three had tibial lengthening for limb length discrepancy. Follow-up ranged between 14 and 43 months (mean : 28 + − 10 months) following the removal of the external fixator. The perimeter, cross- sectional area, volume and the mean signal intensity was calculated from the obtained T1 weighted axial images. Values were compared with the contralateral tibia that acted as control. All cases that had bone transport increased the volume of the tibia from 15.3% up to 50.8%. The regenerated segment was noted to have expanded significantly (p<
0.0001) in all cases. Mean signal intensity in the regenerate decreased in seven cases significantly (p<
0.0001) suggesting increase content of unhydrated tissue such as bone and collagen. The cross-sectional surface of the transported segment was increased in all cases (p<
0.008). Finally in cases that underwent bone transport, the docking site was noted to be obstructed by unhydrated tissue. Contrary to previous claims, the post-distraction osteogenesis tibia is far from normal, consisting of areas with potentially different biomechanical properties. Recognition of these changes is essential not only for appropriate pre-operative counselling but also for considering treatment modalities in case of a fracture.
We present our technique for arthrodesis of the failed Keller’s excisional arthroplasty and the results of postoperative follow-up in a series of eight patients [nine feet]. Arthrodesis of the first metatarsophalangeal joint was performed with a tricortical interposition bone graft stabilised between the first metatarsal and proximal phalanx with a mini dental plate. In all cases the indication for the procedure was for chronic pain at the first meta-tarsophalangeal joint and transfer metatarsalgia of the lateral rays. Post-operative follow-up ranged from 13– 70 months and patients were evaluated using a custom-made satisfaction questionnaire, clinical examination and evaluation of pre-and post-operative x-rays. All patients were female. The mean age of the patients was 53.2 years [range 32–69]. The post- operative questionnaire revealed that five patients [six cases] were highly satisfied with the surgery. However, we do report complications associated with the procedure including one case of deep infection and four cases in total of radiological non-union of the graft. The majority of patients were highly satisfied with the surgery, but this technique for the revision of failed Keller’s procedures has a significant risk of complications, so patients should receive appropriate counselling pre-operatively. Although the mini dental plate was low profile, its decreased rigidity may have been responsible for the four cases of non-union.
We determined the effect of the surgical approach on perfusion of the femoral head during hip resurfacing arthroplasty by measuring the concentration of cefuroxime in bone samples from the femoral head. A total of 20 operations were performed through either a transgluteal or an extended posterolateral approach. The concentration of cefuroxime in bone was significantly greater when using the transgluteal approach (mean 15.7 mg/kg; 95% confidence interval 12.3 to 19.1) compared with that using the posterolateral approach (mean 5.6 mg/kg; 95% confidence interval 3.5 to 7.8; p <
0.001). In one patient, who had the operation through a posterolateral approach, cefuroxime was undetectable. Using cefuroxime as an indirect measure of blood flow, the posterolateral approach was found to be associated with a significant reduction in the blood supply to the femoral head during resurfacing arthroplasty compared with the transgluteal approach.
The degree of spinal canal encroachment was determined from coronal sections of the CT scan by measuring the antero- posterior diameter (APD) and the surface area (Area). (APD 18.84% – 80.62%, Area 9.5% – 81.29%). Average period of follow up was 24.8 months. All Frankel Group C improved to Frankel D and six out of the 13 Frankel D patients improved to Frankel E. The other seven Frankel D patients out of the 13 patients also had improvement in motor scores but did not change Frankel grade.
The meniscal repairs were carried out by a single surgeon over a period of 4 years. 30 patients ( 1st set) had isolated meniscal repairs. 9 patients ( 2nd set) had meniscal repairs and ACL reconstruction at the same time. 11 patients (3rd set) had meniscal repair followed by ACL reconstruction few months later. The patients were seen in the clinic at 2, 6, 24 weeks post surgery and then kept under surveillance.
There was only 1 failure in the 2nd set who needed partial menisectomy 19 months post repair. This gives it a failure rate of 11.1%. In the 3rd set, there were 2 failures out of whom one needed partial menisectomy and other needed re-repair using the arrows at 3 and 7 months respectively post repair at the time of ACL reconstruction, a failure rate of 18.8%.
Repair of distal biceps tendon rupture is a subject that has received increasing attention in the past decade. In the active individual who desires as close to normal function as possible, repair of biceps tendon is recommended. The author describes a tehnique with a single anterior incision and fixation with superanchors. This method was successfully used in 25 patients with excellent functional results. There were no failures and no complications of neurological injury. The single anterior incision approach in which superanchors are used is recommended as an alternative to the traditional two-incision method. The Biceps brachii is an important flexor of the elbow and is the main supinator of the forearm. Avulsion of its distal tendon insertion is rare injury that mostly affects middle-aged men. It represents only 3% of all biceps tendon ruptures. There is an average of 1.24 spontaneous complete distal biceps ruptures per 100,000 people per year. The decline in the number of distal biceps tendon ruptures with increasing age correlates with a decrease in at-risk activities after the fourth decade of life. Decreased vascularity, tendon impingement, degenerative changes of the distal biceps tendon and the use of anabolic steroids have been postulated to predispose to tendon rupture. Our study shows that repair of distal biceps tendon ruptures using superanchors is safe and gives clinically objective and functional results similar to bone tunnel fixation. We had no major complications, no suture anchor failures and no occurrence of synostosis and neurological injuries. We recommend the use of superanchors for the treatment of distal biceps tendon ruptures.
Do patients’ recollections of disease severity following joint replacement surgery accurately reflect their pre-operative disability? Oxford Knee score questionnaires were sent to 100 patients who had undergone primary knee replacement surgery between January 1998 and July 2000.They were asked to complete these in a manner reflecting their pre-operative disability. The results were then compared with actual scores completed by the same group of patients prior to their surgery. The response rate was 78%.The mean pre-operative score was 45 compared to the recall score of 46.9. The difference was not significant (p=0.77).We believe that recall of disability using a simple knee score is a reliable method of assessing pre-operative disability.
There is a legal and ethical obligation to gain informed consent before treatment commences. A number of bodies have issued guidelines for obtaining consent and these include the Department of Health, the GMC, The Royal College Surgeons of England, and the B.O.A. For a patient to give their informed consent to surgery they must receive sufficient information about their illness, proposed treatment and its prognosis. There are no specific guidelines regarding joint replacement. With this in mind a retrospective case note study was undertaken involving 100 patients who had undergone a hip replacement. Noting the documented discussion at all stages of patient contact.Fifty percent of patients had been seen and listed in the Outpatients by a Consultant, 25% were discussed with the Consultant responsible and the remainder were listed without Consultant input. In only 33 % of cases were any specific risks recorded. This had fallen to 4% on their visit to pre operative assessment clinic. All the consent forms were completed at the time of admission for surgery. Forty percent of these on the day of surgery. The majority were completed by SHOs (58%), while only 4% were completed by consultants. None of the forms noted the lead surgeon. All the consent forms noted some frequently occurring risks. However there was a large variance in the details recorded. The study highlights that the majority of complications are only documented on the consent form, with little note of the dialogue leading up to it. It is also apparent that there is no agreement as to what represents a significant or frequent complication. This review raises a number of important issues. There needs to be a national standardisation of the process of consent. We propose the introduction of a specific consent form for hip replacements that provide improved documentation of the standardised risks involved. This should also include guidelines regarding prosthesis choice, surgical approach and the extent of trainee involvement. In addition we would also suggest there is a need to improve sequential documented discussion up to the point of surgery and introduce specific training for juniors carrying out consent.
We explored the association of post-operative pyrexia following hip arthroplasty and the development of deep infection
The metabolic response of trauma may mimic infection and the reliability of serological parameters for diagnosing infection may be questionable. We prospectively assessed the changes in the acute inflammatory markers, febrile response and the immune profiles of 101 patients following primary hip arthroplasty and their association with infection.
Pyrexia in the post-operative setting has often been associated with a possible systemic or wound infection. We assessed whether there is any justification for our concern regarding post-operative pyrexia following hip arthroplasty and subsequent deep prosthetic infection. We undertook an assessment of the clinical outcome of 97 sequential patients who underwent 103 primary hip arthroplasty for primary osteoarthritis replacements. Daily temperature and systemic complications in the post-operative period were recorded. Clinical outcome was measured using an Oxford hip questionnaire. Patients had a mean follow-up of 5.2 years (range 3.5–7.2years) We reviewed the postoperative temperature records of 80 patients who had undergone primary total hip replacement. Thirty-one patients had required revision surgery at a mean time interval of 37.2 months (range 5–74 months) for confirmed deep prosthetic infection. The remaining Forty-nine patients were asymptomatic at a mean follow-up of 31.5 months. Study 1 Post-operative pyrexia of 38 degrees Celsius was present in 51% of patients undergoing primary hip replacement in the first post-operative week but in 21.1% no etiological cause could be identified. Clinical outcome measured by an Oxford hip questionnaire was not influenced by the post-operative temperature pattern. Study 2 The mean peak temperature on the first post-operative day was significantly lower in patients with deep prosthetic infection then patients with a clinically normal outcome (p=0.01). Post-operative pyrexia is clearly not uncommon following primary arthroplasty and its presence should not be regarded as detrimental. Pyrexia in the postoperative setting is a component of the acute phase response to trauma and study 2 demonstrates patients who develop a low-grade infection following arthroplasty may have a diminished febrile response to surgical trauma which may be an indirect representation of a diminished immune response to surgical trauma or infection
Fatal pulmonary embolism (PE) after total hip replacement (THR) is a major concern to all orthopaedic surgeons. Our intention was to ascertain death rates and deaths due to PE following total hip replacement where chemical thromboprophylaxis was not used routinely. We determined retrospectively, the postoperative mortality and fatal pulmonary embolism rates in 1671 consecutive primary total hop replacements in 1547 patients performed as staged procedures between January 1997 and April 2000 at an orthopaedic hospital. The minimum follow-up period was six weeks period after surgery at an orthopaedic hospital. Patients were traced by questionnaires, outpatient appointments and by telephone. Post-mortem records were used to verify cause of death. Follow-up was 100%. The death rate from PE was 0. 12% (CI 0. 03% – 0. 44%) and the all-cause mortality rate was 0. 36% (CI 0. 16% – 0. 78%). All deaths were within the first 10 days during the initial hospital stay. The patient mortality was compared with the population mortality for England and Wales, using standardised mortality ratios (SMRs). The SMR for both sexes combined was 0. 81. We observed a lower mortality in females (SMR=0. 43) but a higher mortality in males (SMR=1. 44) during the first 42 postoperative days compared to the general population. Fatal PE after THR without routine chemical thromboprophylaxis is very uncommon. The death rate in patients undergoing THR appears to be lower than that in the general population.
Cross match practice for patients with femoral neck fractures continue to cause concern due to a failure of compliance to the existing protocols. We addressed this issue by conducting a number of studies over three years and we report the summation of the studies and demonstrate the reasons for the poor compliance. We provide a simple and effective protocol that has helped reduce preoperative cross matching of femoral neck fractures from 71% to 16.7% two years after its introduction.
Retrospective review of the cross-match practice for 240 femoral neck fractures and reviewed the changes in pre-operative and post-operative haemoglobin levels and association with surgical procedure.
Postal questionnaire of 129 anaesthetic and orthopaedic trainees assessing the perceived cross-match requirements of patients with femoral neck fractures based on preoperative haemoglobin values between 8–13g/dl. In addition reviewed the source of trainees perceptions and practice Study 3 Review of the efficiency of the cross-match protocol two years after its introduction Results
71% patients with femoral neck fractures were cross-matched at admission but only 29% of the patients were subsequently transfused. From the 384 units of blood ordered at admission 230 were returned unused. Inter-trochanteric fractures had a mean blood loss of 3.1g/dl (range 1.5–7.2g/dl) following surgery in comparison to a mean loss of 1.7g/dl (0.9–3.4g/dl) for patients with displaced subcapital fractures
Orthopaedic trainees at all levels of training requested more blood then their anaesthetic counterparts for patients with femoral neck fractures. There was misconceptions regarding blood loss following surgery amongst all trainees and only 14.3% trainees used existing literature to guide their cross-match practice where as 53.4% devised protocols based on their own or colleagues’ experience.
Cross-match protocol was working effectively. Only 16.7% of the patients with femoral neck fractures were cross-matched on admission. Conclusion Cross-match recommendations fail to influence trainees. In order to address this we produced a protocol that does not rely on orthopaedic trainees. The haematology MLSO provides the appropriate amount of preoperative blood for the patient based on our finding of blood loss of different fracture patterns and the patients’ preoperative haemoglobin level. Our results show our protocol is still effective two years following its introduction despite numerous changes in trainees during this period.
This study was performed to evaluate the pre-operative concerns of patients undergoing total knee or hip replacement surgery. A cross-sectional study of 370 patients was performed. The patients completed a postal questionnaire on 29 concerns, each rated on a scale of 1 (not concerned) to 4 (very concerned). SF-12 and Oxford knee or hip scores were also calculated. Analysis was carried out using chi-squared test. 217 questionnaires were returned. The results showed that the greatest concern for patients was cancellation of their operation. This was followed by failure of the operation to reduce pain, loss of a limb and joint infection. Concerns regarding scar problems, nursing care and preoperative tests were the lowest. Women showed statistically significant greater concerns in 9 areas. Younger patients (age<
65) showed increased concerns in 8 areas. Patients who had previously undergone joint replacement were less concerned than those who had not had previous lower limb joint replacements for 6 responses. They showed increased concern in 2 areas, nursing care and hospital food. Those undergoing total hip replacement were more concerned about dislocation, dressing and returning to work (all p<
0.05). The mean Oxford Knee or Hip Score was 42.96 and 45.12 respectively (scale 12–60, 60 being most severe symptoms). The mean SF-12 scores were 41.14 for the mental component and 28.70 for the physical component score (scale 0–100, 100 representing greatest level of good health). The mean level of concern is low at 1.9 (scale 1 to 4). It is encouraging that patients who have had a previous joint replacement are generally less concerned. Possible reasons for increased concerns amongst women and younger patients are discussed. SF-12 and Oxford Knee/Hip Scores are comparable with other studies. In conclusion, this study provides useful information for the preoperative counselling of patients and the production of pre-operative literature.