header advert
Results 1 - 66 of 66
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 29 - 29
23 Apr 2024
Ahmed T Upadhyay P Menawy ZE Kumar V Jayadeep J Chappell M Siddique A Shoaib A
Full Access

Introduction

Knee dislocations, vascular injuries and floating knee injuries can be initially managed by a external fixator. Fixator design constructs include the AO pattern and the Diamond pattern. However, these traditional constructs do not adhere to basic principles of external fixation. The Manchester pattern knee-spanning external fixator is a new construct pattern, which uses beam loading and multiplanar fixation. There is no data on any construct pattern. This study compares the stability of these designs.

Materials & Methods

Hoffman III (Stryker, USA) external fixation constructs were applied to articulated models of the lower limb, spanning the knee with a diamond pattern and a Manchester pattern. The stiffness was loaded both statically and cyclically with a Bose 3510 Electroforce mechanical testing jig (TA Instruments). A ramp to load test was performed initially and cyclical loading for measurement of stiffness over the test period. The results were analysed with a paired t-test and ANOVA.


Bone & Joint Open
Vol. 5, Issue 4 | Pages 286 - 293
9 Apr 2024
Upadhyay PK Kumar V Mirza SB Shah N

Aims

This study reports the results of 38 total hip arthroplasties (THAs) in 33 patients aged less than 50 years, using the JRI Furlong hydroxyapatite ceramic (HAC)-coated femoral component.

Methods

We describe the survival, radiological, and functional outcomes of 33 patients (38 THAs) at a mean follow-up of 27 years (25 to 32) between 1988 and 2018.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 29 - 29
1 Nov 2022
Khan S Kapoor L Kumar V
Full Access

Abstract

Background

Reconstruction following resection of sarcomas of the upper extremity with methods described in the prevalent literature may not be possible in few selected cases. We describe Surgical Phocomelia or Phoco-reduction as a method of limb salvage in such cases of extensive sarcomas of the upper limb with its functional and oncological outcomes.

Methods

Evaluation of functional and oncological outcomes was performed for 11 patients who underwent surgical phocomelia or phocoreduction for extensive sarcomas of the upper limb between 2010 and 2019.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 27 - 27
1 Nov 2022
Khan S Kapoor L Kumar V
Full Access

Abstract

Background

Conventional periacetabular pelvic resections are associated with poor functional outcomes. Resections through surgical corridors beyond the conventional margins may be helpful in retaining greater function without compromising the oncological margins.

Methods

The study included a retrospective review of 82 cases of pelvic resections for pelvic tumors. Outcomes of acetabulum preservation (Group A) were compared with complete acetabular resection (Group B). Also, we compared outcomes of Type I+half resections (Group 1) with Type I+II resections (Group 2), and Type III+half resections (Group 3) with Type II+III resections (Group 4).


Abstract

Background

Extracorporeal radiation therapy (ECRT) has been reported as an oncologically safe and effective reconstruction technique for limb salvage in diaphyseal sarcomas with promising functional results. Factors affecting the ECRT graft-host bone incorporation have not been fully investigated.

Methods

In our series of 51 patients of primary bone tumors treated with ECRT, we improvised this technique by using a modified V-shaped osteotomy, additional plates and intra-medullary fibula across the diaphyseal osteotomy in an attempt to increase the stability of fixation, augment graft strength and enhance union at the osteotomy sites. We analyzed our patients for various factors that affected union time and union rate at the osteotomy sites.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_3 | Pages 13 - 13
1 Apr 2019
Waliullah S Kumar V Rastogi D Srivastava RN
Full Access

Spinal tuberculosis is one of the most common presentations of skeletal tuberculosis. It is one of the major health issues of developing countries as it is associated with significant morbidity and mortality. Pott's paraplegia is a dreaded complication which can result in permanent neurological deficit, unless treated by timely intervention. We evaluated the efficacy of transpedicular decompression and functional recovery in patients of spinal tuberculosis with neurological deficit.

A cohort of 23 patients (15 males and 8 female) with diagnosed spinal tuberculosis and having an average age of 37.5±8.4 years, satisfying our inclusion and exclusion criteria's and giving written informed consent were recruited in our study. All patients were managed by transpedicular decompression and fusion with posterior instrumentation. All the patients were followed up clinically, radiologically and hematologically. Patients were followed up at every six weeks for 4 months and thereafter at three monthly intervals to assess the long term outcomes and complications. Neurological evaluation was done by Frankel grading. Functional outcome was assessed by Visual Analog Score (VAS) and Owestry Disability Index score (ODI score).

All the patients were followed for a minimum of 27 months. At the final follow-up, there was a statistically significant improvement in VAS score and ODI score. Out of 23 patients, all except three patients showed neurological recovery.

We observed that transpedicular decompression is safe and effective approach for management of spinal tuberculosis as it allows adequate decompression of spinal cord while pedicular instrumentation provides stable spinal fixation and helps in early rehabilitation.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 6 - 6
1 Nov 2017
Kumar V O'Dowd D Thiagarajah S Flowers M
Full Access

The accessory navicular (AN) is a separate ossification center for the tuberosity of the navicular that is present in approximately 5–14% of the general population. It produces a firm prominence on the plantar-medial aspect of the midfoot. There may be a co-existent flexible flatfoot, but there is no conclusive evidence of a cause-and-effect relationship between the two conditions. It is usually not symptomatic, and few cases necessitate operative intervention. When symptoms require surgical treatment, excision of the AN, with or without advancement of the posterior tibial tendon, usually is considered.

To describe new technique of AN excision and tibialis posterior tendon advancement (TPTA) using a bio-absorbable tenodesis screw and to investigate the outcome of this cohort in comparison to conventional simple excision.

Retrospective 2 Cohort study. Single surgeon series from single institution. All patients younger than 18 years from Jan 2000 to Aug 2012 undergoing simple excision (SE) or excision with TPTA were identified from the prospectively collected database. Case notes were reviewed and data regarding demographics, indications for surgery, presence of Pes Planus, time from presentation to surgery, length of follow-up, patient satisfaction and complications were recorded. Pain and functional outcome were measured using Visual Analogue Score (VAS) and patient reported outcome measure- Oxford Ankle Foot Questionnaire- Child and Teenager Version.

There were 6 patients in SE group. There were 3 males and 3 females. Mean age at surgery was 13.9 years. Surgical indication was painful swelling in all patients and in addition 1 had pes planus. There were 7 in SE & TPTA group. There were 3 males and 4 females. The mean age at surgery was 13.1 years. Surgical indication was painful swelling in all patients and in addition 1 had hind foot rigidity and 3 had pes planus. Postoperative protocol involved weight bearing with or without cast in SE group and non-weight bearing in cast for 6 weeks in TPA group. All patients reported excellent to good outcome. There were no complications and no reoperations after tendon advancement.

In conclusion, based on our study findings, we think AN excision and TP advancement is a safe and effective technique for symptomatic pain relief. It is a novel technique which achieved excellent to good outcome in our series.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 35 - 35
1 May 2017
Han F Lim J Lim C Tan B Shen L Kumar V
Full Access

Background

The traditional Kocher approach for lateral elbow exposure is often complicated by injury to the posterior interosseous nerve (PIN) and the lateral ulnar collateral ligamentous (LUCL). Kaplan approach is less commonly used, due to its known proximity to the PIN. Extensor Digitorum Communis (EDC) splitting approach allows possible wide surgical exposure and low risk of LUCL damage. The comparison of PIN injury during surgical dissection among these 3 common lateral approaches was not previously evaluated. We aim to determine the anatomical proximity of the PIN in these 3 common lateral elbow approaches and to define a safe zone of dissection for the surgical exposure.

Methods

Cadaveric dissections of 9 pairs of fresh frozen adult upper extremities were performed using EDC splitting, Kaplan and Kocher approach to the radial head sequentially in a randomised order. The radial head and PIN were exposed. A mark was made on the radial head upon the initial exposure during dissection. Measurements from the marked point of the radial head to the PIN were made. Study has been approved by the ethics committee.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1542 - 1547
1 Nov 2016
Sampath Kumar V Tyrrell PNM Singh J Gregory J Cribb GL Cool P

Aims

The purpose of this study was to determine if clinical and radiological surveillance of cartilage tumours with low biological activity is appropriate.

Patients and Methods

A total of 98 patients with an intramedullary cartilage neoplasm in a long bone met our inclusion criteria and were included in the study. These patients had undergone a total of 384 scans. Patients with radiological follow-up of more than three years (46 patients) were divided into two groups: an active group (11 patients) and a latent group (35 patients).


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 30 - 30
1 Dec 2014
Garg S Elzein I Lawrence T Charles E Kumar V Manning P Neumann L Wallace W
Full Access

Background

Nonsurgical treatment of Acromioclavicular joint dislocations is well established. Most patients treated conservatively do well, however, some of them develop persistent symptoms. We have used two different surgical reconstruction techniques for Chronic ACJ dislocation stabilization. The study evaluates the effectiveness of a braided polyester prosthetic ligament and modified Weaver-Dunn reconstruction methods.

Methods

55 patients (mean age 42) with Chronic Acromioclavicular joint dislocation were included in this study. They were treated either by a modified Weaver-Dunn method or a braided polyester prosthetic ligament. Patients were assessed using Oxford shoulder score preoperatively and a minimum of 12 months postoperatively.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1202 - 1206
1 Sep 2014
Kumar V Sharma S James J Hodgkinson JP Hemmady MV

Despite a lack of long-term follow-up, there is an increasing trend towards using femoral heads of large diameter in total hip replacement (THR), partly because of the perceived advantage of lower rates of dislocation. However, increasing the size of the femoral head is not the only way to reduce the rate of dislocation; optimal alignment of the components and repair of the posterior capsule could achieve a similar effect.

In this prospective study of 512 cemented unilateral THRs (Male:Female 230:282) performed between 2004 and 2011, we aimed to determine the rate of dislocation in patients who received a 22 mm head on a 9/10 Morse taper through a posterior approach with capsular repair and using the transverse acetabular ligament (TAL) as a guide for the alignment of the acetabular component. The mean age of the patients at operation was 67 years (35 to 89). The mean follow-up was 2.8 years (0.5 to 6.6). Pre- and post-operative assessment included Oxford hip, Short Form-12 and modified University of California Los Angeles and Merle D’Aubigne scores. The angles of inclination and anteversion of the acetabular components were measured using radiological software. There were four dislocations (0.78%), all of which were anterior.

In conclusion, THR with a 22 mm diameter head performed through a posterior approach with capsular repair and using the TAL as a guide for the alignment of the acetabular component was associated with a low rate of dislocation.

Cite this article: Bone Joint J 2014;96-B:1202–6.


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1106 - 1110
1 Aug 2014
Malhotra R Kiran Kumar GN K. Digge V Kumar V

Giant cell tumour is the most common aggressive benign tumour of the musculoskeletal system and has a high rate of local recurrence. When it occurs in proximity to the hip, reconstruction of the joint is a challenge. Options for reconstruction after wide resection include the use of a megaprosthesis or an allograft-prosthesis composite. We performed a clinical and radiological study to evaluate the functional results of a proximal femoral allograft-prosthesis composite in the treatment of proximal femoral giant cell tumour after wide resection. This was an observational study, between 2006 and 2012, of 18 patients with a mean age of 32 years (28 to 42) and a mean follow-up of 54 months (18 to 79). We achieved excellent outcomes using Harris Hip Score in 13 patients and a good outcome in five. All allografts united. There were no complications such as infection, failure, fracture or resorption of the graft, or recurrent tumour. Resection and reconstruction of giant cell tumours with proximal femoral allograft–prosthesis composite is a better option than using a prosthesis considering preservation of bone stock and excellent restoration of function.

A good result requires demanding bone banking techniques, effective measures to prevent infection and stability at the allograft-host junction.

Cite this article: Bone Joint J 2014; 96-B:1106–10.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 50 - 50
1 Jan 2013
Charles E Kumar V Blacknall J Edwards K Geoghegan J Manning P Wallace W
Full Access

Introduction

The Constant Score (CS) and the Oxford Shoulder Score (OSS) are shoulder scoring systems routinely used in the UK. Patients with Acromio-Clavicular Joint (ACJ) and Sterno-Clavicular Joint (SCJ) injuries and those with clavicle fractures tend to be younger and more active than those with other shoulder pathologies. While the CS takes into account the recreational outcomes for such patients the weighting is very small. We developed the Nottingham Clavicle Score (NCS) specifically for this group of patients.

Methods

We recruited 70 patients into a cohort study in which pre-operative and 6 month post-operative evaluations of outcome were reviewed using the CS, the OSS the Imatani Score (IS) and the EQ-5D scores which were compared with the NCS. Reliability was assessed using Cronbach's alpha. Reproducibility of the NCS was assessed using the test/re-test method. Each of the 10 items of the NCS was evaluated for their sensitivity and contribution to the total score of 100. Validity was examined by correlations between the NCS and the CS, OSS, IS and EQ-5D scores pre-operatively and post-operatively.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 167 - 167
1 Jan 2013
Morris C Kumar V Sharma S Morris M Raut V Kay P
Full Access

Financial impact and patient satisfaction with four different anticoagulants for hip and knee arthroplasty in patients with a previous history of VTE- A prospective randomised trial

Introduction

New generation oral anticoagulants (dabigatran/rivaroxaban) have recently become available for the prevention of venous thromboembolism (VTE) following hip and knee arthroplasty. Traditional therapies (warfarin/low molecular weight heparins) are less costly, but have several limitations.

The aim of this study was to evaluate the financial impact of substituting enoxaparin and warfarin with newer therapies dabigatran and rivaroxaban. A secondary objective was to investigate patient satisfaction with these treatments.

Methods

A randomised prospective study was conducted over a 12 month period. Patients with a history of VTE undergoing hip or knee replacement were randomised to receive one of four anticoagulants for five weeks post surgery. Information was gathered during the hospital stay and then post discharge, by telephone, for five weeks(35 days)to determine costs. The costs included cost of drug, nursing time, blood monitoring and transport costs. The patients were also asked to complete the Duke Anticoagulation Satisfaction Scale (DASS). The DASS is a 26 item questionnaire which has 7 responses for each question.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 42 - 42
1 Jan 2013
Serna S Kumar V Fairbairn K Wiltshire K Edwards K Wallace W
Full Access

Introduction

The conservative management of Sub-Acromial Impingement Syndrome (SAIS) of the shoulder includes both physiotherapy treatment and subacromial injection with local anaesthetic and steroids. The outcome from injection treatment has rarely been evaluated scientifically.

Methods

Patients attending a designated shoulder clinic and diagnosed by an experienced shoulder surgeon as having a SAIS between January 2009 and December 2011 were considered for inclusion in the study. 67 of 86 patients screened completed the study (3 did not meet inclusion criteria; 9 declined to participate; 3 lost to follow-up; 4 developed frozen shoulder syndrome). Each patient had a pre-injection Oxford Shoulder Score (OSS) and was given one subacromial injection of 10ml 0.25% levobupivacaine(Chirocaine) + 40 mg triamcinolone(Kenalog) through the posterior route. Radiograph imaging was also assessed. Follow-up was carried out at 6 to 12 weeks post injection when OSS was repeated. A 6 month follow-up assessment to assess if the patient's improvement in functionality and absence of symptoms indicated that a subacromial decompression operation was not necessary. The percentage of patients showing improvement in OSS was calculated and the difference in OSS pre- and post-injection assessed using a Wilcoxon Signed Rank test.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 88 - 88
1 Sep 2012
Kumar V Malhotra R Bhan S
Full Access

We retrospectively reviewed 54 patients (92 hips) who underwent cementless total hip arthroplasty for bony ankylosis in ankylosing spondylitis between September 1988 and 2002. Clinical assessment was done at follow-up, which envisages assessment of the pain, function, deformities and range of motion using the Harris Hip Score. Radiographic analysis was done. Kaplan-Meier survivorship analysis was done at 5 and 8.5 years using the revision for the removal of femoral component, acetabular component or both due to any cause as the end point.

The mean age of the patients was 25.5 years. The mean duration of follow up was 8.5 years. The average preoperative Harris Hip Score of 49.5 improved to 82.6 post operatively. Post operatively 10 hips had mild to moderate pain. Anterior dislocation occurred in four hips (4.3 %) and sciatic nerve palsy in one hip. Heterotopic ossification was seen in 12 patients, reankylosis rate was 0%. Thirteen arthroplasties were revised due to aseptic loosening. Kaplan-Meier survivorship analysis with revision as end point revealed 98.8% survival at 5 years and 85.8% survival at 8.5 years 11 follow up.

Cementless THA in osseous ankylosis in ankylosing spondylitis is a worthwhile surgical intervention in bony ankylosis. Newfound mobility, manoeuvrability and improved ability to sit comfortably were the outcomes, which alleviated the patients’ daunted morale. However, the technically demanding nature of the procedure should not be underestimated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 115 - 115
1 Sep 2012
Garg B Kumar V Malhotra R Kotwal P
Full Access

A prospective, randomized, controlled trial was performed to compare the outcome of treatment of unstable fractures of the proximal part of the femur with either a sliding hip screw or a short proximal femoral nail antirotation (PFNA-XS, Synthes).

Eighty one patients (April 2007 – May 2008) presenting with unstable fracture of the proximal part of the femur were randomized, at the time of admission, to fixation with use of either a short proximal femoral nail antirotation (n=42) or a sliding hip screw (n= 39). The primary outcome measure was reoperation within the first postoperative year and mortality at the end of one year. Operative time, fluoroscopy time, blood loss, and any intra-operative complication were recorded for each patient. Follow-up was undertaken at 3, 6, and 12 postoperative months and yearly thereafter. Plain AP and lateral radiographs were obtained at all visits. All changes in the position of the implant, complications, or fixation failure were recorded. Hip range of motion, pain about the hip and the thigh, walking ability score and return to work status were used to compare the outcomes.

There was no significant difference between 1 year mortality rates for the two groups. Mean Operative time was significantly less in PFNA group (Mean 25 min, range 19 – 56 min) than DHS group (Mean 38 min, range 28 – 70 min). Patients treated with a PFNA experienced a shorter fluoroscopy time and less blood loss. 6 patients in DHS group had implant failure as compared to none in PFNA group. The functional outcome was also better in PFNA group.

When compared to DHS, PFNA-XS provides better functional outcome for unstable trochanteric fractures with less operative time, less blood loss and less complications, however one year mortality rate remains the same.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 82 - 82
1 Sep 2012
Chandran P Patel K Kumar V Hamed Y Kay P Porter M
Full Access

Introduction

We aim to assess the functional outcome, patient perceived satisfaction and implant survival at a mean follow up of 13[10–16] years following revision knee replacement.

Patients and Methods

Between 1995 and 2001, 243 revision knee replacements were performed in 230 patients using Endolink [Link, Hamburg] or TC3 [Depuy, Leeds] prosthesis at Wrightington hospital, Wrightington, were consented to take part in this study. Data was collected prospectively which includes complications and functional assessment by Oxford knee score, WOMAC, HSS, UCLA, SF12 scores, and patient satisfaction questioner. The scores were obtained pre-operatively and post-operatively at 1 year, 5 years and at the latest follow-up. The mean age was 69 yrs, 51% were males, TC3 prosthesis as used in 175 and Endolink in 68, the revision was for Infection in 71[29%], 53 patients had intra-operative positive culture, 35 had 2 stage revision.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 70 - 70
1 Sep 2012
Kumar V Garg B Malhotra R
Full Access

A prospective, randomized, double-blind study was done on 50 patients undergoing primary cementless total hip arthroplasty to determine the effect of tranexamic acid on intra- and postoperative blood losses and on the transfusions requirements.

50 patients were randomized to tranexamic acid (15 mg/kg) given as a bolus intravenous injection or placebo (normal saline) given intravenously, 15 minutes before the incision.

The intraoperative and postoperative blood loss (at removal of the drain 24 hours after the operation) and the number of blood transfusions required were recorded. The patients were screened for deep venous thrombosis with bilateral compression Ultrasonography using Colour Doppler imaging on the tenth postoperative day. The Hemoglobin level was measured preoperatively and on the 3rd postoperative day. The D-dimer levels were measured preoperatively and 24 hrs postoperatively.

Patients receiving tranexamic acid had a mean intraoperative blood loss of 410 ml (range, 300–510 ml) versus 615 ml (range, 515–750ml) (p value<0.05) in patients receiving placebo, a postoperative blood loss of 210 ml(range, 150–325ml) versus 490 ml(range, 370–540ml) (p value<0.05), and a total need for 8 blood transfusions versus 30. Only 6 out 25 patients in tranexamic acid group required blood transfusion whereas 18 out of 25 patients in the placebo group required transfusion.

In the group receiving placebo the mean fall in hemoglobin was 2.9g/dl (range, 2.5–3.2) and in the group treated with tranexamic acid 1.6 g/dl (1.3–2) (p<0.05). At 24 hrs postoperatively, mean plasma D-dimer concentration in the Tranexamic group was half of that in the control group. No patient in either group had any evidence of deep vein thrombosis on bilateral compression Ultrasonography using Colour Doppler imaging done on the tenth postoperative day.

Tranexamic acid 15 mg/kg given as a single preoperative bolus dose reduces peroperative and postoperative and total blood loss, and transfusion requirements in primary cementless total hip replacement surgery without any increased risk of thrombus formation.


Background

We compared pain relief after total hip arthroplasty using periarticular intraoperative injection along with single dose post operative injection of local anesthetic (THA) with the well-established practice of epidural infusion.

Methods

70 patients undergoing elective THA under combined spinal anaesthesia were randomly assigned to receive either (1) continuous epidural infusion (group B) or (2) infiltration around the hip joint with a mixture of 100 ml of bupivacaine (2 mg/ml) + 1ml ketorolac (30mg/ml) and 0.5ml epinephrine (1mg/ml) at the conclusion of surgery combined with one postoperative intraarticular injection of 20 ml. of Bupivacaine 0.5% + 1ml ketorolac (30mg/ml)+ 0.5 ml. epinephrine (1mg/ml) through an intraarticular catheter (group A).

All patients received acetoaminophen 1gm 8 hourly for 72 hrs and injection ketoralac 30mg every 6 hourly IV(15mg if >65 yr 30mg if <65 yr). Breakthrough pain in any group (VAS >7) was treated by injection fentanyl 20 μg bolus at 10 min. interval till VAS reduced to < 4. If VAS 4–7 injection tramadol 50mg IV was given if VAS continued to be >4 after 15 min. then injection fentanyl 20 μg bolus was given at 10 min interval till VAS <4.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 75 - 75
1 Sep 2012
Garg B Kumar V Malhotra R Kotwal P
Full Access

Adequate exposure is a prerequisite for treatment of distal humeral fractures. In this study, we compared the clinico-radiological and functional outcome of TRAP approach with that of olecranon osteotomy for distal humerus fractures.

27 patients with distal humerus fractures were randomized into 2 groups: Group 1 (n=14, TRAP approach), Group 2 (n=13, Olecranon osteotomy). All patients were operated with bi-columnar fixation. All patients were mobilized from day 2. Follow-up evaluation was done at 1, 3, 6 and 12 months.

All patients achieved union. The mean surgical time was higher in group 1 (120 min) as compared to group 2 (100 min). The final ROM was higher in group 1 (1160) as compared to group 2 (850). Two patients in group 2 needed posterior release. 5 patients in group 2 had hardware complications related to olecranon osteotomy and needed removal. Two patients in Group 1 had transient ulnar nerve paraesthesias. There was no difference in triceps power in both groups.

Our results demonstrate that TRAP approach is extensile and safe enough in treating these complex fractures with better final ROM and fewer complications.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 237 - 237
1 Sep 2012
Chandran P Patel K Kumar V Hamed Y Kay P Porter M
Full Access

Introduction

We aim to assess the functional outcome, patient satisfaction and implant survival at a mean follow up of 13[10–16] years following revision for infected total knee replacement.

Patients and Methods

Between 1995 and 2001, 71 revision knee replacements were performed for infection, at Wrightington hospital, Wrightington. Data was collected prospectively which includes intra-operative cultures, complications and functional assessment by Oxford knee score, WOMAC, HSS, UCLA, SF12 scores, and patient satisfaction questioner. The scores were obtained pre-operatively and post-operatively at 1 year, 5 years and at the latest follow-up. Mean age was 69 yrs, 70% were Females, 31[44%] had 2 stage revisions and intra-operative culture was positive in 53 patients. Most common organism was staphylococcus aureus in 30% and staphylococcus epidermides in 18%.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 569 - 569
1 Sep 2012
Garg B Kumar V Malhotra R Kotwal P Soral A
Full Access

Introduction

Adequate exposure is a prerequisite for treatment of distal humeral fractures. In this study, we compared the clinico-radiological and functional outcome of TRAP approach with that of olecranon osteotomy for distal humerus fractures.

Material & Methods

27 patients with distal humerus fractures were randomized into 2 groups: Group 1 (n=14, TRAP approach), Group 2 (n=13, Olecranon osteotomy). All patients were operated with bi-columnar fixation. All patients were mobilized from day 2. Follow-up evaluation was done at 1, 3, 6 and 12 months.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 258 - 258
1 Sep 2012
Garg B Kumar V Malhotra R Kotwal P Madan M
Full Access

Introduction

Locking plates have been especially useful in the treatment of osteoporotic fractures. This study aimed to investigate the role of locking plate in femoral fractures in patients with osteogenesis imperfecta.

Material & Methods

6 male patients with osteogenesis imperfecta were operated for femoral fractures using locking compression plate. Their age ranged between 4 and 14 years. They were kept non weight bearing till the fracture united.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 525 - 525
1 Sep 2012
Kumar V Garg B Malhotra R
Full Access

Introduction

We compared standard NexGen Cruciate substituting-flex prosthesis with gender-specific NexGen Cruciate substituting flex prosthesis in patients undergoing bilateral total knee arthroplasty with regard to Coverage of the bone by femoral component, Clinical outcome, Radiographic outcome, Survival and complication rates, with special emphasis on patellofemoral complications.

Material & Methods

30 female patients with osteo-arthritis of the knees with similar deformity and preoperative range of motion were randomized to have one knee replaced with a gender non-specific Nexgen Cruciate substituting (Zimmer) prosthesis and the other with Gender Cruciate substituting (Zimmer) prosthesis. Follow-up clinical evaluation was done at 6, and 12 months postoperatively and then at yearly interval using “Knee Society” Recommendations. Clinical assessment of the patellofemoral joint of the replaced knees was done with the help of “Hospital for Special Surgery” patellar scoring system. The overall patient satisfaction after surgery was evaluated with use of the British Orthopaedic Association patient satisfaction score.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 526 - 526
1 Sep 2012
Kumar V Garg B Malhotra R
Full Access

Introduction

Tranexamic acid is an inhibitor of fibrinolysis that blocks the lysine-binding site of plasminogen to fibrin, and thereby decreases blood loss in patients undergoing surgery.

Aims and objectives

A prospective, randomized, double-blind study was done on 100 patients undergoing primary cemented Unilateral Total Knee Arthroplasty to determine the effect of tranexamic acid on intra- and postoperative blood losses and on the transfusions requirements.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 91 - 91
1 Sep 2012
Malhotra R Kumar V
Full Access

25 patients in age group (25–40yrs), 15 males, 10 females were implanted with a short metaphyseal cementless stem (‘Proxima’®, Depuy) and cementless acetabular cup. The average follow up was 2.3 years (1.4–2.5 yrs). Clinical evaluation using Harris Hip Score, Radiological evaluation and Bone Mineral Density were evaluated at 2weeks, 6 months, 12 months and yearly thereafter. a new zonal method suitable for short stem was used for radiological evaluation.

The mean Harris Hip score improved from 44 to 95 at final follow up. There was no evidence of any radiolucent lines or osteolysis around the stems. All the stems showed evidence of osseointegration at one year follow up. There was no decrease in bone mineral density around the stems.

The Short Metaphyseal cementless femoral stem is a bone conserving as well as bone preserving option for young patients especially in those in whom surface replacement is not an option.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 128 - 128
1 Sep 2012
Malhotra R Kumar V
Full Access

Twenty total hip arthroplasty were performed with use of a cementless cup in 17 patients and cemented cup in a cage in 3 patients for the treatment of posttraumatic osteoarthritis following acetabular fracture. The average age of the 4 women and 16 men was 49 (range, 26 to 86 years) at the time of the arthroplasty. The median interval between the time of injury and the total hip arthroplasty was 37 months (range, 8 to 144 months). The average operative time was 120 minutes and average intraoperative blood loss was 700 ml. Eight patients had previous open reduction and internal fixation of the acetabular fracture and twelve had been treated nonoperatively. Following total hip replacement, each patient was evaluated clinically and radiographically at six weeks, three months, six months and twelve months, and then yearly following total hip replacement. The average duration of clinical and radiographic follow-up was 40 months (range, 26 to 60 months).

At the time of final follow-up, of twenty acetabular components, 10 had no evidence of periacetabular radiolucency, 7 components had a partial radiolucency that was <1 mm wide, 2 had a complete radiolucency <1 mm wide and 1 component was surrounded by a complete radiolucency of >2 mm in width without showing component migration. According to Engh's criteria, 16 (80%) femoral stems had bony ingrowth and 4 (20%) stems had stable fibrous ingrowth. The average preoperative Harris hip score improved from 35 points to 78 points at the time of final followup.

Total hip arthroplasty for arthritis following acetabular fractures, technically difficult because of extensive scarring, heterotopic bone, retained internal fixation devices, and residual deformity of the acetabulum.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIV | Pages 5 - 5
1 Apr 2012
Kar M Kumar V Sharma U Deo S Shukla N Jagannathan N Datta Gupta S
Full Access

Aim

Grade is the most important predictor of the biological behaviour of soft tissue sarcomas. Assigning a pathologic grade is always a difficult task as discordance rate is 30-40% even among experienced sarcoma pathologists. Many of these tumours are heterogeneously large and only small fractions are sampled for biopsy. This emphasizes the need for an objective and accurate assessment of histology. Our aim is to evaluate the role of Choline as a tumour marker in (i) differentiating benign from malignant soft tissue tumour, (ii) to distinguish recurrent/residual tumours using in-vivo MR spectroscopy.

Methods

PMRS Study was performed at 1.5Tesla MRI machine of the lesions in 25 patients. Single-voxel (SVS) study has been done in 10 cases and chemical shift imaging (CSI) study characterised the heterogeneity of the tumour in 15 cases by using point – resolved spectroscopic sequence (PRESS) with echo time TR=2000/TE = 30, 135 & 270 msec. The choline peak, identified at 3.2 ppm in spectra was considered significant. MRS results and histopathologic findings were correlated and P < 0.001, considered being significant.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVI | Pages 10 - 10
1 Apr 2012
Kumar V Jani P Bagga T
Full Access

We conducted a retrospective study to compare the blood loss following Primary Total Knee Replacement (TKR) to see effectiveness of Tranexamic acid (TXA).v/s Cell Salvage.

This was a retrospective study conducted from Aug 2008 to Dec 2009. We compared two groups. Group A was given TXA IV (two doses – first dose before tourniquet release and second dose six hours post-operative) and in group B post op cell salvage was used. 84 knees were included in this study with 42 patients in each group. The surgical technique, implants used and post-operative Thromboprophylaxis care were same in both groups.

The corrected mean Hob drop in Group A was 1.76g/dl (Range-0.7 to 4.3) while that in Group B was 2.32g/dl (Range-0.7 to 5.3). Use of TXA lead to a 24.13% decrease in mean Hob drop and 3.7% fall in mean drain output following TKR in our study. Two thromboembolic events in the form of deep vein thrombosis (DVT) confirmed by Duplex US scan, were noted in each group. There was no difference in complication rate i.e. drain site infection and wound leaking in either group. Costs - The cost of two doses of TXA is £3.81 per patient and cost of bellovac drain was £85 per patient.

We found TXA was more effective and cheaper than autolougus blood transfusion and there was no increase in thromboembolic complications


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIV | Pages 4 - 4
1 Apr 2012
Kar M Kumar V Sharma U Deo S Shukla N Jagannathan N Datta Gupta S
Full Access

Aim

Grade is the most important predictor of the biological behaviour of soft tissue sarcomas. Assigning a pathologic grade is always a difficult task as discordance rate is 30-40% even among experienced sarcoma pathologists. Many of these tumours are heterogeneously large and only small fractions are sampled for biopsy. This emphasizes the need for an objective and accurate assessment of histology. Our aim is to evaluate the role of Choline as a tumour marker in (i) differentiating benign from malignant soft tissue tumour, (ii) to distinguish recurrent/residual tumours using in-vivo MR spectroscopy.

Methods

PMRS Study was performed at 1.5Tesla MRI machine of the lesions in 25 patients. Single-voxel (SVS) study has been done in 10 cases and chemical shift imaging (CSI) study characterised the heterogeneity of the tumour in 15 cases by using point – resolved spectroscopic sequence (PRESS) with echo time TR=2000/TE = 30, 135 & 270 msec. The choline peak, identified at 3.2 ppm in spectra was considered significant. MRS results and histopathologic findings were correlated and P < 0.001, considered being significant.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 115 - 115
1 Feb 2012
van Niekerk L Panagopoulos A Triantafyllopoulos I Kumar V
Full Access

Introduction

The purpose of this study is to evaluate the early functional outcome and activity level in athletes and soldiers with large full thickness cartilage defects of the knee that underwent either ‘classic’ autologous chondrocyte implantation using periosteal flap coverage (ACI-P) or 3-D matrix-assisted chondrocyte implantation (ACI-M).

Methods

Between April 2002 and January 2004, 19 patients (15 male, 4 female, average age 32.2 years) with 22 full-thickness cartilage defects in 19 knees were treated with ACI in our centre. The mean post-injury interval was 39.8 months whereas 17 (89.5%) patients had undergone at least one surgical procedure before ACI. The average defect size was 6.54 cm2 (located in MFC:7, LFC:7 or trochlear:2 while 3 patients had bifocal lesions in both LFC and TRC). Novocart¯ cultured chondrocytes with periosteal flap coverage were used in 11 patients and Novocart-3D¯ cell impregnated collagen patch in 8. The functional outcome was evaluated with IKDC form, Tegner activity scale and Lysholm score after a mean follow-up period of 26.5 months.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 3 - 3
1 Feb 2012
Maru M Akra G Kumar V Port A McMurtry I
Full Access

Objective

To compare clinical parameters associated with medial parapatellar and midvastus approaches for total knee arthroplasty in the early post-operative period.

Methods and results

We present a prospective observational study of 77 patients undergoing primary total knee arthroplasty using medial parapatellar(40) or midvastus approach(37). The prosthetic design and physical intervention was standardised in all the patents. The Oxford Knee Score, pain scale, knee flexion, unassisted straight leg raise, standing and walking were compared at 3rd, 5th and 7th day post-operatively, then at 6 weeks and at 3 months. The patients and physiotherapist were blinded to the type of approach used. The average age was 67 years (range 42 to 88). There were 42 women and 35 men. The average hospital stay was 7 days (range 2 to 15). There was statistically significant difference in duration of hospital stay, unassisted straight leg raise and standing at 3 days (p=0.001) and pain scale at 5 days, all in favour of midvastus approach. There was no statistically significant difference in Oxford Knee Scores and duration to achieving full flexion and walking. The average duration to achieving straight leg raise for the midvastus group was 5 days and for the medial parapatellar approach group was 8 days.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 28 - 28
1 Feb 2012
Kumar V Panagopoulos A Triantafyllopoulos J Fitzgerald S van Niekerk L
Full Access

Aim

The aim of this study was to compare the diagnostic accuracy of the Magnetic Resonance Imaging with that of Stress views of the ankle in testing the integrity of the lateral ankle ligaments. Arthroscopic diagnosis was used as the gold standard.

Methods

This was a prospective study involving 45 patients who had previous trauma to the ankle and reported symptoms of ankle instability. Our patients were recreational athletes or military patients. These patients had MRI evaluation prior to arthroscopic evaluation and treatment of the ankle. The diagnosis regarding the integrity of the Calcaneofibular ligament (CFL) and the Anterior Talo-fibular ligament (ATFL), as obtained from the MRI was compared against the assessment of integrity from the stress views. These were compared against the assessment made by direct visualisation of the ligaments during arthroscopy. The sensitivity, specificity, negative (NPV) and positive predictive values (PPV) and accuracy were then calculated.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 209 - 209
1 May 2011
Kumar V Garg B Malhotra R
Full Access

Background: Joint replacements are being performed on ever younger patients at a time when average expectancy of life is continuing to rise. Any reduction in the strength and mass of periprosthetic bone could threaten the longevity of implant by predisposing to loosening and migration of prosthesis, periprosthetic fracture and problems in revision arthroplasty.

Aims and Objectives: This study aims to analyse and compare prospectively the femoral periprosthetic stress-shielding around 4/5th and 1/3rd porous coated cementless femoral stems in patients undergoing unilateral cementless total hip replacement done using DEXA scan by quantifying the changes in bone mineral density around femoral component.

Material and Method: Femoral periprosthetic bone mineral density was measured in the seven Gruen Zones with DEXA scan at 2 weeks, 1 years and 2 years after surgery in 60 patients who had undergone unilateral cementless total hip replacement, of which 30 patients had been implanted with 4/5th porous coated stems and other 30 patients with 1/3rd porous coated stems.

Results: At both one and two years postoperatively, bone loss due to stress-shielding was seen in both stems with maximum loss in zone VII and minimum in zone III, IV, V. The maximum mean percentage bone mineral density loss in 4/5th porous coated stems in zone VII was 16.03% at one year and 22.42% at 2 years as compared to loss of 10.07% and 16.01% in 1/3rd porous coated stems. Increased bone loss was seen in patients who had larger diameter stem (> 13.0 mm) and in patients with low bone mineral density in the unoperated hip.

Conclusion: Bone loss as a result of stress-shielding is more pronounced in 4/5th porous coated stems as compared to 1/3rd porous coated stems.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 113 - 113
1 May 2011
Malhotra R Kumar V Eachempati K Bhan S
Full Access

Background: Durable long-term independent results with the Low Contact Stress rotating-platform (mobile-bearing) and the Insall Burstein-II (fixed-bearing) total knee prostheses have been reported, but no studies describing either the mid-term or long-term results and comparing the two prostheses are available, to our knowledge.

Methods: Thirty-two patients who had bilateral arthritis of the knee with similar deformity and preoperative range of motion on both sides and who agreed to have one knee replaced with a mobile-bearing total knee design and the other with a fixed-bearing design were prospectively evaluated. Comparative analysis of both designs was done at a mean follow-up period of six years, minimizing patient, surgeon, and observer-related bias. Clinical and radiographic outcome, survival, and complication rates were compared.

Results: Patients with osteoarthritis had better function scores and range of motion compared with patients with rheumatoid arthritis. However, with the numbers available, no benefit of mobile-bearing over fixed-bearing designs could be demonstrated with respect to Knee Society scores, range of flexion, subject preference, or patellofemoral complication rates. Radiographs showed no difference in prosthetic alignment. Two knees with a mobile-bearing prosthesis required a reoperation: one had an early revision because of bearing dislocation and another required conversion to an arthrodesis to treat a deep infection.

Conclusions: We found no advantage of the mobile-bearing arthroplasty over the fixed-bearing arthroplasty with regard to the clinical results at mid-term follow-up. The risk of bearing subluxation and dislocation in knees with the mobile-bearing prosthesis is a cause for concern and may necessitate early revision.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 210 - 210
1 May 2011
Malhotra R Eachempati K Kumar V
Full Access

Introduction: The occurrence of bony ankylosis in ankylosing spondylitis (AS) is not precisely known. Bony ankylosis, especially in stiff spine may present several exclusive challenges in its management. The current study is an endeavor to evaluate the clinical and the radiological results of cementless THA in patients with bony ankylosis of hip due to ankylosing spondylitis.

Materials and Methods: We retrospectively reviewed 54 patients (92 hips) who underwent cementless total hip arthroplasty for bony ankylosis in ankylosing spondylitis between September 1988 and 2002. Clinical assessment was done at follow-up, which envisages assessment of the pain, function, deformities and range of motion using the Harris Hip Score. Radiographic analysis was done. Kaplan-Meier survivorship analysis was done at 5 and 8.5 years using the revision for the removal of femoral component, acetabular component or both due to any cause as the end point

Results: The mean age of the patients was 25.5 years. The mean duration of follow up was 8.5 years. The average preoperative Harris Hip Score of 49.5 improved to 82.6 post operatively. Post operatively 10 hips had mild to moderate pain. Anterior dislocation occurred in four hips (4.3 %) and sciatic nerve palsy in one hip. Heterotopic ossification was seen in 12 patients, reankylosis rate was 0%. Thirteen arthroplasties were revised due to aseptic loosening. Kaplan-Meier survivorship analysis with revision as end point revealed 98.8% survival at 5 years and 85.8% survival at 8.5 years 11 follow up

Discussion: Cementless THA in osseous ankylosis in ankylosing spondylitis is a worthwhile surgical intervention in bony ankylosis. Newfound mobility, maneuverability and improved ability to sit comfortably were the outcomes, which alleviated the patients’ daunted morale. However, the technically demanding nature of the procedure should not be underestimated


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 207 - 207
1 May 2011
Malhotra R Kancherla R Kumar V Jayaswal A
Full Access

Introduction: Spine fractures are common manifestation of osteoporosis. After an acute osteoporotic vertebral compression fracture pain persisting even after 3 months and clinical tenderness should raise the suspicion of pseudarthrosis. Pseudarthrosis is not a rare complication of a benign osteoporotic vertebral collapse occurs in about 10% of cases after an acute collapse. Treatment plan needs to be individualized. Cement augmentation procedures such as kyphoplasty and vertebroplasty can be performed in the absence of neurological deficit, whereas decompression and stabilization is necessary in presence of neurological deficit.

Study Design: Prospective cohort study

Methods: 31 patients who were diagnosed to have an acute osteoporotic vertebral compression fracture were managed conservatively. Pain persisting after 3 months and clinical tenderness in 5 patients prompted further investigation, revealing pseudarthrosis. None of them had neurological deficit. Imaging of two patients revealed vacuum sign with intravertebral cleft on plain radiographs and on MRI. All of them were at the Dor-solumbar junction and of crush typeof VCF.

Results: The incidence of pseudoarthrosis after an oste-porotic VCF was found to be 16.12%. One patient was treated with kyphoplasty, one with vertebroplasty with good pain relief and restoration of functional ability, and rest three are awaiting kyphoplasty.

Conclusion: High suspicion of pseudarthrosis is to be kept in mind as it is not an uncommon complication of benign osteoporotic collapse. Vertebral augmentation procedures such as kyphoplasty and vertebroplasty are promising procedures for treatment in absence of neurological deficit.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 122 - 122
1 May 2011
Kumar V Nataraj A Garg B Malhotra R
Full Access

Chronic infection of bone with nonunion is traditionally treated by a 2-stage procedure involving initial debridement and antibiotic delivery and then definitive internal fixation. Alternatively, external fixators are used to provide stability. A technique with which single stage antibiotic cement-coated intramedullary nails are prepared in the operating room with the use of Kuntscher Nails and materials that generally are available is described herein. Although useful for all infected nonunions this technique is particularly useful for patients who are not ideal candidates for external fixation and for those who do not want to have an external fixator applied. We evaluated 10 cases treated with antibiotic cement-coated K nail with application of an additional unicortical plate in 7 cases. Autologous iliac crest bone grafting was done in all cases and additional bone substitutes used in 2 cases. 9 patients had stable union with complete control of infection. One patient had persistent infection at the time of last follow


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 552 - 552
1 Oct 2010
Kumar V Garg B Malhotra R
Full Access

Introduction: Factures of the acetabulum are the result of high-energy trauma. Long-term function of the hip joint is compromised in many cases as a result of imperfect reduction, chondral injuries to the acetabulum, femoral head lesion and post-traumatic avascular necrosis of the femoral head.Total hip arthroplasty is one of the treatment option for such patients who present with symptomatic post-traumatic arthritis or avascular necrosis with collapse of the femoral head following acetabular fractures

Materials and Methods: Twenty total hip arthroplasty were performed with use of a cementless cup in 17 patients and cemented cup in a cage in 3 patients for the treatment of posttraumatic osteoarthritis following acetabular fracture. The average age of the 4 women and 16 men was 49 (range, 26 to 86 years) at the time of the arthroplasty. The median interval between the time of injury and the total hip arthroplasty was 37 months (range, 8 to 144 months). The average operative time was 120 minutes and average intraoperative blood loss was 700 ml. Eight patients had previous open reduction and internal fixation of the acetabular fracture and twelve had been treated nonoperatively.Following total hip replacement,each patient was evaluated clinically and radiographically at six weeks, three months, six months and twelve months, and then yearly following total hip replacement. The average duration of clinical and radiographic follow-up was 40 months (range, 26 to 60 months).

Results: At the time of final follow-up, of twenty acetabular components, 10 had no evidence of periacetabular radiolucency, 7 components had a partial radiolucency that was < 1 mm wide,2 had a complete radiolucency < 1 mm wide and 1 component was surrounded by a complete radiolucency of > 2 mm in width without showing component migration. According to Engh’s criteria,16 (80%) femoral stems had bony ingrowth and 4 (20%) stems had stable fibrous ingrowth. The average preoperative Harris hip score improved from 35 points to 78 points at the time of final followup.

Conclusion: We conclude that total hip arthroplasty for degenerative arthritis following acetabular fractures,is a gratifying but often technically more difficult than a routine total hip arthroplasty because of extensive scarring, heterotopic bone, retained internal fixation devices, and residual deformity of the acetabulum.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 393 - 394
1 Jul 2010
Kumar V Malhotra R Bhan S
Full Access

Background: Joint replacements are being performed on ever younger patients at a time when average expectancy of life is continuing to rise. Any reduction in the strength and mass of periprosthetic bone could threaten the longevity of implant by predisposing to loosening and migration of prosthesis, periprosthetic fracture and problems in revision arthroplasty.

Aims & Objectives: This study aims to analyse and compare prospectively the femoral periprosthetic stress-shielding around 4/5th and 1/3rd porous coated cementless femoral stems in patients undergoing unilateral cementless total hip replacement done using DEXA scan by quantifying the changes in bone mineral density around femoral component.

Material & Method: Femoral periprosthetic bone mineral density was measured in the seven Gruen Zones with DEXA scan at 2 weeks, 1 years and 2 years after surgery in 60 patients who had undergone unilateral cementless total hip replacement, of which 30 patients had been implanted with 4/5th porous coated stems and other 30 patients with 1/3rd porous coated stems.

Results: At both one and two years postoperatively, bone loss due to stress-shielding was seen in both stems with maximum loss in zone VII and minimum in zone III, IV, V. The maximum mean percentage bone mineral density loss in 4/5th porous coated stems in zone VII was 16.03% at one year and 22.42% at 2 years as compared to loss of 10.07% and 16.01% in 1/3rd porous coated stems. Increased bone loss was seen in patients who had larger diameter stem (> 13.0 mm) and in patients with low bone mineral density in the unoperated hip.

Conclusion: Bone loss as a result of stress-shielding is more pronounced in 4/5th porous coated stems as compared to 1/3rd porous coated stems.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 447 - 447
1 Jul 2010
Kumar V Manish K Javed A Khan SA Yadav CS Rastogi S
Full Access

Ossyfying periarticular lipoma is a very rare entity. Lipomas undergo involutional changes like chondrification, calcification and very rarely ossification. These changes result in altered clinical, radiological and histopathological features leading to diagnostic challenge in differentiation from the soft tissue tumor like synovial sarcoma, liposarcoma and rhabdomyosarcoma.

We present a series of three cases of ossifying lipomas presenting as soft tissue tumor around the knee, shoulder and hip joints. All the tumors revealed calcification and ossification on plain X-rays and on MRI/CT Scans. Clinico-radiological evaluation lead to a similar diagnostic dilemma in our series and a confirmed diagnosis of ossifying lipoma became possible only after histopathology. All the three tumors were excised completely without any recurrence during last 3 1/2 years of follow-up.

We recommend the early imaging by MRI/CT scan with closed core biopsy to exclude the malignant pathology and complete excision of the tumor with early mobilization of the adjacent joint.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 393 - 393
1 Jul 2010
Malhotra R Kumar V
Full Access

Introduction: There has been an introduction of short femoral stems with the aim of conserving bone. We present the short term results of short metaphyseal cement-less stem(Proxima®, Depuy).

Material and methods: 25 patients in age group (25–40yrs), 15 males,10 females were implanted with a short metaphyseal cementless stem (Proxima®, Depuy) and cementless acetabular cup. The average follow up was 2.3 years (1.4–2.5 yrs). Clinical evaluation using Harris Hip Score, Radiological evaluation and Bone Mineral Density were evaluated at 2weeks, 6 months, 12 months and yearly thereafter. a new zonal method suitable for short stem was used for radiological evaluation.

Results: The mean Harris Hip score improved from 44 to 95 at final follow up. There was no evidence of any radiolucent lines or osteolysis around the stems. All the stems showed evidence of osseointegration at one year follow up. There was no decrease in bone mineral density around the stems.

Discussion: The Short Metaphyseal cementless femoral stem is a bone conserving as well as bone preserving option for young patients especially in those in whom surface replacement is not an option.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 304 - 304
1 May 2010
Kumar V Sharma L Malhotra R
Full Access

Background: Joint replacements are being performed on ever younger patients at a time when average expectancy of life is continuing to rise. Any reduction in the strength and mass of periprosthetic bone could threaten the longevity of implant by predisposing to loosening and migration of prosthesis, periprosthetic fracture and problems in revision arthroplasty.

Aims & Objectives: This study aims to analyse the femoral periprosthetic stress-shielding following unilateral cementless total hip replacement using DEXA scan by quantifying the changes in bone mineral density around femoral component.

Materials and Methods: Femoral periprosthetic bone mineral density was measured in the seven Gruen Zones with DEXA scan at 2 weeks, 1 year and 2 year after surgery in 60 patients who had undergone unilateral cementless total hip replacement, of which 30 patients had been implanted with 4/5th porous coated CoCr stems and other 30 patients with 1/3rd porous coated titanium alloy stems.

Results: At both one and two years postoperatively, bone loss due to stress-shielding was seen in both stems with maximum loss in zone VII and minimum in zone III, IV, V. The maximum mean percentage bone mineral density loss in 4/5th porous coated CoCr stems in zone VII was 16.03% at one year and 22.42% at 2 years as compared to loss of 10.07% and 16.01% in 1/3rd porous coated Ti alloy stems. Increased bone loss was seen in patients who had larger diameter stem (> 13.0 mm) and in patients with low bone mineral density in the unoperated hip.

Conclusion: Bone loss as a result of stress-shielding is more pronounced in 4/5th porous coated CoCr stems as compared to 1/3rd porous coated titanium alloy stems.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 142 - 142
1 Mar 2009
Kumar V Panagopoulos A Triantafyllopoulos I van Niekerk L
Full Access

Background: Stress radiography and more recently magnetic resonance imaging have been used to study the integrity of lateral ankle ligaments in chronic symptomatic instability after injury.

Aim: Our aim was to see if magnetic resonance imaging was as good as examination under anaesthesia and stress radiography, for diagnosing injury to the lateral ankle ligaments.

Study Design: Cross-over study.

Methods: Fifty eight patients, 47 men and 11 women, were included in the study. These were athletes or military personnel with symptomatic instability of the ankle after injury. This cohort of patients had MRI scans, stress radiographs and arthroscopic treatment of their ankle. Integrity of the calcaneo-fibular ligament (CFL) was recorded arthroscopically. The sensitivity, specificity, positive and negative predictive value of MRI and stress views, in assessing integrity of the CFL, were compared against the arthroscopic findings which was considered to be the gold standard.

Results: Stress radiography under anaesthesia and MRI has sensitivities of 94% and 47% and specificities of 98% and 83% for diagnosing injury to the CFL, respectively. Stress radiography has a higher accuracy in diagnosing CFL injuries as compared to MRI.

Conclusion: The results of this study casts doubt on the efficacy of MRI in the diagnosis of serious ankle ligament injuries.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 539 - 539
1 Aug 2008
Kumar V Malhotra R Bhan S
Full Access

Background: Joint replacements are being performed on ever younger patients at a time when average expectancy of life is continuing to rise. Any reduction in the strength and mass of periprosthetic bone could threaten the longevity of implant by predisposing to loosening and migration of prosthesis, periprosthetic fracture and problems in revision arthroplasty.

Aims & Objectives: This study aims to analyse the femoral periprosthetic stress-shielding following unilateral cementless total hip replacement using DEXA scan by quantifying the changes in bone mineral density around femoral component over a period of one year and identify the factors influencing the bone loss.

Material & Method: Femoral periprosthetic bone mineral density was measured in the seven Gruen Zones with DEXA scan at 2 weeks, 3 months and 1 year after surgery in 20 patients who had undergone unilateral cementless total hip replacement, of which 10 patients had been implanted with 4/5th porous coated CoCr stems and other 10 patients with 1/3rd porous coated titanium alloy stems.

Results: At both 3 months and one year postoperatively, bone loss due to stress-shielding was seen in both stems with maximum loss in zone VII and minimum in zone III, IV, V. The maximum mean percentage bone mineral density loss in 4/5th porous coated CoCr stems in zone VII was 16.03% at 3 month and 22.42% at 1 year as compared to loss of 10.07% and 16.01% in 1/3rd porous coated Ti alloy stems. Increased bone loss was seen in patients who had larger diameter stem (> 13.0 mm) and in patients with low bone mineral density in the unoperated hip.

Conclusion: Bone loss as a result of stress-shielding is more pronounced in 4/5th porous coated CoCr stems as compared to 1/3rd porous coated titanium alloy stems.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 321 - 321
1 Jul 2008
Patil S Kumar V Kamath V White L Dixon J Hui A
Full Access

Introduction: Poor proprioception and imbalance between quadriceps and hamstrings have been suggested as causes for anterior knee pain. The aim of our study was to compare the proprioception of patients with anterior knee pain to a normal population and to compare the activity of quadriceps and hamstrings using electromyography (EMG) in the 2 groups.

Methods: Patients and controls between the ages 11–25 yrs were recruited into the study. The proprioception (stability index) of the patients and controls was tested using the Biodex stability system. This computerised system tests the ability of a person to balance his/her own body on a platform that moves in various directions. Surface EMG was recorded from the quadriceps and hamstrings during this test. EMG was also recorded as the patients and controls stepped onto a 20cm step. EMG activity was normalised to levels elicited during maximal isometric contractions.

Results: 18 patients and 27 controls were recruited.

We found no significant difference between the groups in the EMG intensity of vastus lateralis relative to biceps femoris, or vastus medialis relative to vastus lateralis, during the balance test or during the step up task (Mann Whitney U test all p> 0.05). We did not find any difference in the proprioceptive abilities of the two groups

Conclusion: We found no significant difference between the groups in the intensity of muscle contraction of the hamstrings relative to the quadriceps, i.e. no evidence for an imbalance in the patients. However the temporal relation between the two needs further investigation.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 324 - 324
1 Jul 2008
Kumar V Panagoupolous A Triantafyllopoulos JK van Niekerk L
Full Access

Background & Aim: Recent studies have claimed good results after ACI in athletes. Our aim was to evaluate the early functional outcome and activity level after 2-stage ACI in professional athletes and soldiers.

Methods: Thirteen soldiers and five professional athletes (14 men and 4 women; average age 31 years), with 21 full thickness cartilage defects (ICRS grade-IV) of the knee were treated with 2-stage ACI. Mean interval between injury and surgery was 43.8 months. Average defect size was 6.03 cm2 and was located to the MFC in 7 cases, LFC in 7 cases and the femoral trochlea in one case. The functional outcome was evaluated with ICRS form, Tegner activity rating scale and Lysholm score after a mean follow up period of 23.4 (18–32) months.

Results: The ICRS and Lysholm scores were improved from 42.7 and 47.6 pre-operatively to 63.1 and 69.9 respectively. The average Tegner scale was 8.8 pre-injury, 3.7 prior to surgery and 6.4 at the final follow up. Nine patients (50%) underwent second-look arthroscopy for persistent mechanical symptoms. Periosteal flap overgrowth was identified in 6 cases with adequate graft integration while partial failure of the graft was noted in one case and was treated with microfracture.

Conclusions: The early results of ACI in high-performance athletes and professional soldiers are not as good as other studies suggest. Returning to pre-injury performance levels for athletes and military people is by no means assured in the first 24 months after ACI.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 230 - 231
1 Jul 2008
Kumar V Attar F Maru M Adedapo A
Full Access

Aim: Our aim was to measure plantar foot pressures in normal individuals and to compare them with variations in patients with metatarsalgia.

Methodology: We measured the plantar foot pressures in different parts of the foot in normal subjects of various ages and then compared this with foot pressures of patients with metatarsalgia. For measurement and statistical analysis, the plantar contact of the foot was divided into six anatomical divisions. The foot pressures were measured under the hallux, head of first metatarsal, over heads of second, third and fourth metatarsals, the fifth metatarsal, midfoot and hindfoot. This was measured using the FSCAN insole pedobarograph system (Tekscan, Inc, Boston, MA).

The foot pressures were measured in Kilopascals(Kpa). Independent T-tests was used to compare mean pressure distributions in the six anatomical divisions. We found the mean pressures through the 5th metatarsal head – 217(t=−2.32,p< 0.05) and midfoot 94(t=−3.17, p< 0.05), were significantly higher when compared to pressures in normal subjects (table 1).

Conclusion: We have demonstrated increased pressures transmitted through the outer aspect of the sole of the foot, in patients suffering from metatarsalgia. This can be used further to plan any foot- orthosis or surgery to distribute pressures more evenly across the sole of the foot.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 382 - 382
1 Jul 2008
Kumar V Kanabar P Owen P Rushton N
Full Access

Background: To analyse the effectiveness and complications of Less Invasive Stabilisation System (LISS plate) in the management of peri-prosthetic femoral fractures.

Materials and methods: We present a study of 18 peri-prosthetic femoral fractures around hip arthroplasty (16 females and 2 male patients) treated with LISS plate between September 2001 to February 2005. The average age of the patients was 81.6 years. Twelve patients had significant co-morbidities pre-operatively. All the fractures were classified according to the Vancouver classification for Peri-prosthetic fracture of femur. Ten were classified as type B1, two as type B2 and six as type C. Eleven fractures were around total hip replacement and seven were around hemi-arthroplasty (four cemented and 3 uncemented). Partial weight bearing started early post-operatively. Full weight bearing varied between 5-6 weeks depending on clinical and radiological status. The patients were followed up untill fracture union.

Results: Three patients died during the follow-up period owing to unrelated causes. The average follow up period was 11.7 months. All the remaining fifteen patients had satisfactory fracture union although one patient required further LISS plate following a fall 17 days postoperatively and another one patient developed low grade deep infection with a chronic sinus. It was noted that in one patient, plate had lifted off the bone at the proximal end with no loss of reduction of the fracture. Three patients were noted to have mild to moderate discomfort around the prominent implant. No implant breakage noted.

Conclusions: Even though LISS plate was originally designed for distal femoral fracture treatment, it appears to be very promising device in the treatment of peri-prosthetic femoral fractures (Type B1, Type C and medically unfit patients with Type B2 for stem- revision) with osteoporotic bone in elderly patients. Early mobilization is a key feature. This system involves minimally invasive approach, stable construct without need for primary bone grafting.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 323 - 323
1 Jul 2008
Kumar V Panagopoulos A Triantafyllopoulos JK van Niekerk L
Full Access

Background: The medial patellofemoral ligament (MPFL) is the principle medial stabilizer of the patella. It is damaged after traumatic patella dislocation. We describe a reproducible technique for MPFL reconstruction and our preliminary results at 12 months.

Material-methods: 25 patients (19 men, 6 women; average age 26.9 years-old) with post-traumatic patellar instability underwent MPFL reconstruction at a mean post-injury interval of 22.3 months. Five patients had evidence of generalized laxity, 3 had trochlear dysplasia and 16 (64%) more than two episodes of dislocation. Arthroscopic assessment revealed associated chondral lesions in 88% and marked lateralization. The reconstruction was performed using ipsilateral semitendinosus tendon. With the distal attachment preserved, the proximal end is passed through the medial intermuscular membrane and secured to the medial border of the patella. Clinical pre- and post-operative assessments included IKDC, Tegner, Lysholm and Kujala scores. ICRS documentation recorded the contribution of articular cartilage damage, whereas Merchant views and MRI scans documented the abnormal radiological parameters and the damaged structures of the medial retinaculum respectively.

Results: At a mean follow up period of 12 months (8–18 months) no cases of re-dislocation were recorded. The Tegner and IKDC scores averaged 4.2 and 46.9 pre-injury. Postoperatively they had improved to 7.7 and 86.5. The average postoperative Lyshom- and Kujala scores were 87 and 89 respectively. Re-operation was required in one patient after patellar fracture 8 weeks post reconstruction.

Conclusion: Our preliminary results suggest surgical reconstruction of the MPFL provide a favorable early outcome for the treatment of post-traumatic patellofemoral instability and will form the basis for longer follow up in a larger cohort.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 319 - 319
1 Jul 2008
Maru M Kumar V Akra G Port A
Full Access

Introduction: The commonest surgical approach for total knee arthroplasty is medial parapatellar approach. This involves splitting the quadriceps tendon, potentially destabilising the extensor mechanism. The midvastus approach involves splitting the vastus medialis muscle instead of entering the quadriceps tendon, therefore, minimising interruption of the extensor mechanism without compromising the exposure of the knee.

Objective: To compare clinical parameters associated with medial parapatellar and midvastus approaches for total knee arthroplasty in the early postoperative period.

Methods and results: We present a prospective observational study of 88 patients undergoing primary total knee arthroplasty using medial parapatellar or midvastus approach (44 in each group). The prosthetic design and physical intervention was standardised in all the patents. The Oxford Knee Score, pain scale, knee flexion, unassisted straight leg raise, standing and walking were compared at 3rd, 5th and 7th day postoperatively, then at 6 weeks and at 3 months. The patients and physiotherapist were blinded to the type of approach used. The average age was 67 years (range 42 to 88). There were 49 women and 39 men. The average hospital stay was 7 days (range 2 to 15). There was statistically significant difference in duration of hospital stay, unassisted straight leg raise and standing at 3 days (p=0.001) and pain scale at 5 days, all in favour of midvastus approach. There was no statistically significant difference in Oxford Knee Scores and duration to achieving full flexion and walking. The average duration to achieving straight leg raise for the midvastus group was 5 days and for the medial parapatellar approach group was 8 days

Conclusion: The study shows that total knee arthroplasty performed through the midvastus approach resulted in less postoperative pain, earlier unassisted straight leg raise and ambulation, therefore, shorter hospital stay as compared to medial parapatellar approach. This may be of benefit to the patients due to less discomfort after surgery, and to the healthcare system due to shorter hospital stay for patients.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 334 - 334
1 Jul 2008
Kumar V Hameed A Bhattacharya R Attar F McMurtry I
Full Access

Aim: 1. To assess the role of the CT scan in management of intra-articular fractures of the calcaneum. 2. Does the scan makes any difference to the management decision, obtained from assessing the plain radiograph?.

Methodology: This study involved 24 patients with intra-articular fracture of the calcaneum who had both a plain radiograph and a CT scan as a part of their assessment. Three consultants who were blinded to the actual management and names of the subjects were independently asked to grade the radiographs and CT scans, as operative or non-operative, on different occasions. The data was matched to the actual management and was subjected to statistical analysis.

Results: The data was non-parametric and related. The SIGN test was used to analyse the agreement between the three observers and if the decisions made in each of the groups were significantly different from the actual management. There was no statistically significant difference, between the management decision from the radiographs or CT and the actual management.

The change in management that the CT scan brought about was also assessed for each of the observers using the McNemars test. The CT scan did not make any significant difference to the decision made based on the plain radiographs, on whether to operate or not.

A Cochran Q test used to assess the variability of the decisions, showed that there was more inter-observer variability in decision making, using the CT based assessment (Q=9.50, p=0.009) as compared to plain radiographs (Q=3.84, p=0.14).

Conclusion: We conclude that, the CT scan should only be requested when a decision is made to operate on the fracture, based on plain radiographs. This may help with pre-operative planning of fracture fixation. It does not have to be obtained as a routine to assess all intra-articular fractures of the calcaneum.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 230 - 230
1 Jul 2008
Kumar V Bhattacharyam R Attar F Hameed A McMurty I
Full Access

CT- scan as an management tool is being used extensively in managing calcaneal fractures. We set out to see if a CT-scan makes any difference to the management plan as obtained by looking at the plain radiograph. We also looked at the correlation with the actual management.

Methodology: This was a retrospective study involving 24 patients with fracture of the calcaneum. These patients had both a plain radiograph and a CT- scan to help decide on management. The actual management that each of these patients had was documented. Three consultants who were blinded to the actual management and names of the subjects were independently asked to grade the radiographs, as operative or non-operative. They were then similarly, asked to decide on operation or no-operation based on blinded CT- scans. The data obtained from the three observers were compared to the actual management and were subjected to statistical analysis.

Results: As the data was categorical and matched, the Mcnemars test was used to test the association between the management plan obtained from the radiographs and the management plan obtained from the CT scans, for each consultant. They were also compared with the actual management. The statistical analysis showed that there was no statistically significant association between the management decision obtained from the radiographs and the CT san, for all three observers. Radiograph and CT scan based management decisions also did not correlate with the actual management.

Conclusion: The CT scan should only be done when a definite decision is made to operate on a patient, based on plain radiographs. Calcaneal fractures which are decided not to operate, based on X rays, should not have a CT scan as a routine as it provides no valuable additional information.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 406 - 406
1 Oct 2006
Kumar V Maru M Attar F Adedapo A
Full Access

Introduction Plantar foot pressure measurements using pressure distribution instruments is a standard tool for diagnostic and therapeutic interventions. Foot pressure studies have measured pressure distributions in patients with various conditions such as rheumatoid arthritis, diabetes and obesity . Pressure studies in metatarsalgia and Hallux rigidus, to our knowledge, has not been reported previously. Our aim was to measure plantar foot pressures in normal individuals and to compare them with variations in patients with metatarsalgia and Hallux rigidus. This data may enable us to identify areas of abnormal pressure distributions and thus plan foot-orthosis or surgical intervention.

Materials and Methods This was a case control study. We measured the plantar foot pressures in different parts of the foot in normal subjects of various ages and then compared this with foot pressures of patients with metatarsalgia and hallux rigidus. For measurement and statistical analysis, the plantar contact of the foot was divided into six anatomical divisions. The foot pressures were measured under the hallux, head of first metatarsal, over heads of second, third and fourth metatarsals, the fifth metatarsal, midfoot and hindfoot. This was measured using the FSCAN insole pedobarograph system (Tekscan, Inc, Boston, MA).

Results The foot pressures were measured in Kilopascals(Kpa). Independent T-tests was used to compare mean pressure distributions in the six anatomical divisions. Comparing normal with metatarsalgia, the mean pressures through the 5th metatarsal head 217(t=−2.32,p< 0.05) and midfoot 94(t=−3.17, p< 0.05), were significantly higher when compared to pressures in normal subjects. In patients with hallux rigidus, the mean pressures through the hallux 314 (t=−3.62, p< 0.01) and mid-foot 140 (t=-5.11, p< 0.01), were significantly higher, as compared to pressures in normal subjects.

Discussion Metatarsalgia is a condition that presents with pain under the region of the 2nd to 4th metatarsal heads. Hence, the normal response of the body would be to avoid putting increased pressure through this region, thus causing increased pressures to be transmitted through other parts of the foot. The foot pressures through the hallux and midfoot were higher in patients with hallux rigidus (compared to normal). This results in pressure imbalances and thus may contribute to pain, deformity and abnormal gait. Our study, confirms this, the mean plantar foot pressures were higher under the 5th metatarsal head and the midsole as compared to normal subjects. This could be explained by the tendency to walk on the outer aspect of the sole to avoid the painful area. Thus, any foot orthosis or surgery should aim to redistribute these forces.

Conclusion We have demonstrated increased pressures transmitted through the outer aspect of the sole of the foot, in patients suffering from metatarsalgia. The pressures through the Hallux and midfoot were higher in oatients with hallux rigidus. This information can be used further to plan any foot-orthosis or surgery to distribute pressures more evenly across the sole of the foot.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 275 - 276
1 May 2006
Kumar V Attar F Adedapo A
Full Access

Objective: Our aim was the record variation in foot pressures through parts of the foot, in normal subjects and compare with foot pressure distribution in patients with conditions of the foot such as symptomatic hallux rigidus and metatarsalgia.

Methodology: This was an observational study. We assessed the foot pressure distributions in 30 normal subjects, using the foot pressure pedobarograph system. The foot pressures were measured through the Hallux, 1st Metatarsal head, 2,3,4th metatarsal heads, 5 metatarsal head, midfoot and hindfoot. Foot pressure in patients with hallux rigidus and metatarsalgia were compared with the pressures in normal subjects, using statistical analysis.

Results: The foot pressures were measured in Kilopascals(Kpa). Independent T test was used to compare pressures. In patients with hallux rigidus, the mean pressures through the hallux 314 (t= −3.62, p< 0.01) and midfoot 140 (t=−5.11, p< 0.01), were significantly higher, as compared to pressures in normal subjects. In patients with metatarsalgia, the mean pressures through the 5th metatarsal head 217 (t=−2.32, p< 0.05) and midfoot 94 (t=−3.17, p< 0.01), was significantly higher when compared to pressures in normal subjects.

Conclusion: The foot pressures through the hallux and midfoot were higher in patients with hallux rigidus (compared to normal). Thus any foot orthosis or surgery should aim to relieve the pressure through these regions. Whereas, foot pressures through 5th metatarsal head and midfoot were higher in patients with metatarsalgia (compared to normal). This reflects the adaptation the foot develops to avoid the painful region and thus any orthosis or surgery should try to spread the foot pressures evenly across the foot.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 274 - 274
1 May 2006
Kumar V Hui AC
Full Access

Aim: This study compares the MRI scan with clinical diagnosis, and looks at the reliability of both these against the gold standard of arthroscopic diagnosis, in disorders of the knee.

Materials and methods: The patients were from the knee specialist unit of a tertiary referral centre seen and operated by the senior author , over a two year period. This is a retrospective study. The total number of patients in this study was 58(n=58) , with ages ranging from 18–63 years. The results were obtained using statistical formulae, which calculated the sensitivity , Specificity , accuracy and the positive and negative predictive values of the MRI scan and that of clinical diagnosis .

Results: The MRI scan was found to be significantly sensitive in diagnosis of medial meniscal lesions, 96% (95% Confidence interval 89–100), it was also found to be significantly specific in diagnosis of lateral meniscal, 90% ( 95% CI, 81–98) and ACL lesions 94% (95% CI,87–100). The MRI scan had poor sensitivity and specificity for articular cartilage lesions.

The sensitivity of clinical diagnosis for medial and lateral meniscus and ACL lesions was found to be less than 90%. Clinical impression was found to be significantly specific for lesions of ACL and the articular cartilage.

The negative predictive value of the MRI scan was found to be significantly high (> 95%), for lesions of the medial and lateral meniscus and the ACL.

Conclusion: The MRI had a poor diagnostic value in diagnosing and quantifying articular cartilage (chondral) lesions. Clinical diagnosis had a lower sensitivity as compared to MRI in diagnosis of medial meniscal lesions but was more specific in diagnosing cruciate and articular cartilage pathology. The reliability of a high negative predictive value for the MRI scan in ruling out medial meniscus, lateral meniscus and ACL lesion was demonstrated. Therefore, a ‘normal’ scan can be used to exclude lesions. thus sparing patients from expensive and unnecessary surgery and also freeing up valuable theatre time.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 251 - 251
1 May 2006
Bhattacharya R Kumar V Hui A
Full Access

Purpose of the study: To determine usefulness of skyline x-ray in diagnosis of patellofemoral osteoarthritis.

Materials and Methods: 50 patients scheduled to undergo knee surgery, had standard antero-posterior, lateral and skyline x-rays of their affected knee. At operation, their patellofemoral joints were graded into two groups according to presence or absence of osteoarthritis. Their lateral and skyline x-rays were also graded into the same two groups, according to presence or absence of patellofemoral osteoarthritis. The two x-ray views were then compared individually against operative findings.

Results: The skyline view had sensitivity of 79% (95% confidence intervals (C.I.) 66% to 93%) and specificity of 80% (95% C.I. 62% to 98%). The lateral view had sensitivity of 82% (95% C.I. 69% to 95%) and specificity of 65% (95% C.I. 44% to 86%).

Conclusion: There was no statistically significant difference between the two x-ray views in terms of sensitivity and specificity in the diagnosis of patellofemoral osteoarthritis of the knee joint. Hence, we cannot recommend the skyline view as a routine radiological investigation in all cases of suspected patellofemoral osteoarthritis.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 276 - 276
1 May 2006
Kumar V Attar F Savvidis P Anderson J
Full Access

Aim: Assessing Polyethylene wear is very important in following up patients after Total hip replacement (THR) and Livermore method (using callipers) is routinely used by clinicians in calculating this wear. Our aim was to assess if ‘Imagika’, a new computer software programme can accurately assess polyethylene wear(PE-wear). We also compared the computer software with the Livermore method in calculating wear.

Method: We used 15 different THR X rays of patients who had an ABG total hip replacement done. X rays that were included for the calculations were taken at different time intervals following the operation. Wear was calculated on each X ray by 3 clinicians using both the methods, on 3 separate occasions. We compared the Livermore method and the computer software for consistency of measurements and also calculated the inter and intra observer variability for both.

Results: There was a statistically significant difference (at the 5% level) between the measurements taken by the Imagika software and the Livermore method. F(1,88) = 5.38, p< 0.05. There was a statistically significant difference in the inter-observer measurements using the Livermore method. F(2,42) = 4.18, p< 0.05, but there was no significant inter-observer variation using the Imagika computer software. There was no statistically significant difference (at the 5%level) in the intra-observer variability of both groups.

Conclusion: The Imagika computer software proved to be better than the Livermore method in calculating wear with regards to inter-observer bias. There was also a significant difference between measurements taken using both methods. We conclude that the computer software may be a more accurate tool in the assessment of PE-wear in the future.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 602 - 603
1 Jul 1993
Fachartz O Kumar V al Hilou M

Schistosomiasis is a common parasitic infestation in Egypt. We describe the case of a 24-year-old Egyptian man who presented with the signs of acute septic arthritis of the hip and in whom biopsy subsequently revealed schistosome ova in the synovium.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 509 - 509
1 May 1993
Kumar V Satku K


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 150 - 151
1 Jan 1990
Satku K Chia J Kumar V


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 815 - 817
1 Nov 1988
Kumar V Satku K Helm R Pho R

Seven patients with segmental defects of both bones of the forearm had reconstruction operations using a vascularised fibular graft to bridge the radius. Reasonable forearm rotation was preserved with full elbow movements and satisfactory hand function.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 309 - 311
1 Mar 1987
Satku K Kumar V Pho R

Three women with osteoarthritis of the knee presented after sudden worsening of their symptoms. In each case this was found to be due to a stress fracture of the tibia. With treatment by rest and reduced activity, the fracture healed uneventfully in all three patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 458 - 461
1 May 1986
Satku K Kumar V Ngoi S

Untreated anterior cruciate ligament injuries in 97 knees of 87 patients were reviewed after a mean interval of six years. After their initial recovery 63% of the patients were able to return to their pre-injury sport, but six years later 27% of them had deteriorated to the extent that they could not cope with the same level of sport. Radiological deterioration was maximal in those that had had a meniscectomy more than five years before review. Knees with intact menisci were often radiologically normal despite continuing instability.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 5 | Pages 719 - 721
1 Nov 1985
Kumar V Balasubramaniam P

The role of atmospheric pressure in providing static stability of the shoulder was studied experimentally in 24 cadaveric shoulders. Atmospheric air was allowed to enter the joint after puncturing the capsule. Three types of experiment were performed: in the first, the capsule was punctured after sequential division of the muscles; in the second, atmospheric air was let in by percutaneous puncture of of the capsule without dividing the muscles; and in the third, air was first let into the joint by percutaneous puncture of the capsule and then the muscles of the shoulder were divided. It was found that the intact shoulder subluxated after percutaneous puncture even without division of the overlying muscles or the capsule. Our findings suggest that negative pressure and muscle tone are the main static stabilisers of the shoulder, rather than the joint capsule.