Abstract
Twenty total hip arthroplasty were performed with use of a cementless cup in 17 patients and cemented cup in a cage in 3 patients for the treatment of posttraumatic osteoarthritis following acetabular fracture. The average age of the 4 women and 16 men was 49 (range, 26 to 86 years) at the time of the arthroplasty. The median interval between the time of injury and the total hip arthroplasty was 37 months (range, 8 to 144 months). The average operative time was 120 minutes and average intraoperative blood loss was 700 ml. Eight patients had previous open reduction and internal fixation of the acetabular fracture and twelve had been treated nonoperatively. Following total hip replacement, each patient was evaluated clinically and radiographically at six weeks, three months, six months and twelve months, and then yearly following total hip replacement. The average duration of clinical and radiographic follow-up was 40 months (range, 26 to 60 months).
At the time of final follow-up, of twenty acetabular components, 10 had no evidence of periacetabular radiolucency, 7 components had a partial radiolucency that was <1 mm wide, 2 had a complete radiolucency <1 mm wide and 1 component was surrounded by a complete radiolucency of >2 mm in width without showing component migration. According to Engh's criteria, 16 (80%) femoral stems had bony ingrowth and 4 (20%) stems had stable fibrous ingrowth. The average preoperative Harris hip score improved from 35 points to 78 points at the time of final followup.
Total hip arthroplasty for arthritis following acetabular fractures, technically difficult because of extensive scarring, heterotopic bone, retained internal fixation devices, and residual deformity of the acetabulum.