header advert
Results 41 - 60 of 83
Results per page:

We compared the ceiling effects of two patient-rating scores, the Disability of the Arm, Shoulder and Hand (DASH) and Patient-Rated Wrist Evaluation (PRWE), and a physician-rating score, the Modified Mayo Wrist Score (MMWS) in assessing the outcome of surgical treatment of an unstable distal radial fracture. A total of 77 women with a mean age of 64.2 years (50 to 88) who underwent fixation using a volar locking plate for an unstable distal radial fracture between 2011 and 2013 were enrolled in this study. All completed the DASH and PRWE questionnaires one year post-operatively and were assessed using the MMWS by the senior author. The ceiling effects in the outcome data assessed for each score were estimated.

The data assessed with both patient-rating scores, the DASH and PRWE, showed substantial ceiling effects, whereas the data assessed with MMWS showed no ceiling effect.

Researchers should be aware of a possible ceiling effect in the assessment of the outcome of the surgical treatment of distal radial fractures using patient-rating scores. It could also increase the likelihood of a type II error.

Cite this article: Bone Joint J 2015;97-B:1651–6.


Introduction

We describe a single stage arthroscopic procedure for the treatment of articular cartilage defects in the knee. The novel procedure involves microdrilling and application of atellocollagen and fibrin gel. The aim of the study was to evaluate the clinical outcomes at 4 years.

Materials and Methods

A prospective study of 30 patients with symptomatic ICRS grade III/IV chondral defects which were assessed clinically and radiologically. The lesions were located on the MFC, LFC, trochlea or patella, ranging from 2–8cm2. The surgical procedure involved debridement of the lesion, microdrilling and application of atellocollagen and fibrin gel under CO2 insufflation. Patients were clinically assessed using the Lysholm, IKDC and KOOS scores. Radiological assessment used the MOCART score.


We describe a novel single stage arthroscopic repair procedure for articular cartilage defect in the knee. The aim of the study was to evaluate the clinical and radiological outcomes at two years.

The pre-clinical study involved two groups of New Zealand rabbits, treated with microfracture alone and microfracture combined with fibrin gel and concentrated bone marrow aspirate cells (BMAC) application. New cartilage from both groups was studied with histological staining, immunohistochemistry and electron microscopy. The fibrin gel-BMAC group scored better than the microfracture group on all counts.

This is a prospective study of 30 patients with symptomatic ICRS grade III/IV chondral defects, ranging from 2–8 cm2, which were assessed clinically and radiologically. The surgical procedure involved debridement of the lesion, microfracture and arthroscopic application of concentrated BMAC with fibrin gel under CO2 insufflation. Patients underwent morphological MRI, quantitative T2*-mapping and d-GEMRIC scan. Clinical assessment was carried out using the Lysholm, IKDC and KOOS scores while radiological assessment used the MOCART score.

At 2 year follow-up, Lysholm score was 80.1, as compared to 50.8 pre-operatively (p < 0.05). KOOS (symptomatic) was 92.1, as compared to 65.7 pre-operatively. IKDC (subjective) was 83, up from 39 preoperatively. The mean T2* relaxation-times for the repair tissue and native cartilage were 29.1 and 29.9 respectively. Average MOCART score for all lesions was 72.

Our technique shows encouraging clinical and radiological results. The morphological MRI shows good cartilage defect filling and the biochemical MRI (T2*-mapping) suggests hyaline like repair tissue.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 10 - 10
1 Jul 2014
Kim S Hong J Yoon H Kwon B Lee I Kim H
Full Access

Summary Statement

Obovatol inhibits receptor activator of nuclear factor kappa B ligand (RANKL)-induced osteoclastogenesis and prevents inflammatory bone loss in mice

Introduction

Adult skeletal mass and integrity are maintained by balancing osteoclast-mediated bone resorption and osteoblast-induced bone formation during bone remodeling. Abnormal increases in osteoclastic bone resorption can lead to excessive bone destruction as observed in osteoporosis, rheumatoid arthritis, and metastatic cancers Therefore, Modulation of osteoclast formation and function is a promising strategy for the treatment of bone-destructive diseases. To search for compounds that inhibit osteoclast formation, we tested the effect of obovatol, a natural product isolated from the medicinal plant Magnolia obovata, on osteoclastogenesis and inflammatory bone loss.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 264 - 264
1 Dec 2013
Nam KW Choi S Nam U Seo K Kim S Kim HJ
Full Access

Introduction:

Whole blood metal ion level and clinical outcomes of ceramic-on-metal bearing were comparable to ceramic-on-ceramic THA in this prospective randomized controlled trial.

Methods:

We randomized 150 consecutive THA cases at one institution into two groups: Group I and Group II. Group I, 75 cases, received a THA using ceramic-on-metal couplings and Group II, 75 cases, received ceramic-on-ceramic bearing THA. The implant differed only in the bearing surfaces used. We compared the serum levels of cobalt (Co) and chromium (Cr) and functional outcome scores preoperatively, and at 2, 6, and 12 months postoperatively.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 377 - 377
1 Dec 2013
Ko KR Lee KH Kim S Lim S Moon Y
Full Access

Introduction:

The robot-assisted cementless total hip arthroplasty has theoretical advantages of providing better fit and mechanical stability of the stem. However, no previous study has been reported on a short stem implantation using surgical robot. We compared early clinical and radiographic results between robotic milling and manual rasping in short stem total hip arthroplasty.

Materials & Methods:

We designed a prospective randomized controlled trial to determine whether robot-assisted short stem total hip arthroplasty improves the implant position represented by stem alignment, leg length equality, and reduces the intraoperative and early postoperative complications. A total of 40 patients were enrolled with informed consents and randomly assigned to robotic milling group (20 hips) and manual rasping group (20 hips) by means of a computer-generated random number table. There were no statistically significant differences in the demographics of the patients between the two groups


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 399 - 399
1 Dec 2013
Lim S Lee KH Ko KR Kim S Moon Y Park Y
Full Access

Introduction:

Ceramic head with titanium-alloy sleeve offers a modular ceramic head solution for the damaged taper in revision total hip arthroplasty (THA). It can also be used in primary THA to reduce the risk of ceramic head fracture. The purpose of the present study was to report the intermediate-term outcomes of primary ceramic-on-ceramic THA with use of ceramic head with titanium-alloy sleeve.

Materials & Methods:

We evaluated 244 patients (271 hips) who had undergone primary ceramic-on-ceramic THA with use of BIOLOX® forte 32 mm ceramic head with titanium-alloy sleeve between November 2005 and August 2009. There were 158 males (175 hips) and 86 female (96 hips) patients with a mean age of 55.5 years. Clinical and radiographic evaluation was performed at a mean of 4.6 years (range, 2–7 years) postoperatively.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 396 - 396
1 Dec 2013
Lee KH Ko KR Kim S Lim S Moon Y Park Y
Full Access

Introduction:

The management strategy regarding optimally addressing polyethylene wear with a well-fixed acetabular shell remains controversial. The purpose of the present study was to document outcomes of cementation of a highly cross-linked polyethylene (PE) liner into a well-fixed acetabular metal shell in 36 hips

Materials & Methods:

We identified 37 patients (39 hips) who had undergone revision THA by cementation of a highly cross-linked PE liner into a well-fixed metal shell between June 2004 and April 2009. Of these patients, one (1 hip) died before the end of the 3-year evaluation and another was lost to follow-up. Thus, the study cohort consisted of 35 patients (36 hips). There were 23 males (24 hips) and 12 female (12 hips) patients with a mean age at time of revision surgery of 57.6 years (range, 38–79 years). All operations were performed by a single surgeon using only one type of liner. Clinical and radiographic evaluation was performed at a mean of 6.1 years (range, 3–8 years) postoperatively.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 578 - 582
1 May 2013
Kim S Postigo R Koo S Kim JH

The timing of total hip replacement (THR) in patients with active tuberculosis (TB) of the hip is controversial, because of the potential risk of reactivation of infection. There is little information about the outcome of THR in these patients. We conducted a systematic review of published studies that evaluated the outcome of THR in patients with active TB of the hip. A review of multiple databases referenced articles published between 1950 and 2012. A total of six articles were identified, comprising 65 patients. TB was confirmed histologically in all patients. The mean follow-up was 53.2 months (24 to 108). Antituberculosis treatment continued post-operatively for between six and 15 months, after debridement and THR. One non-compliant patient had reactivation of infection. At the final follow-up the mean Harris hip score was 91.7 (56 to 98). We conclude that THR in patients with active TB of the hip is a safe procedure, providing symptomatic relief and functional improvement if undertaken in association with extensive debridement and appropriate antituberculosis treatment.

Cite this article: Bone Joint J 2013;95-B:578–82.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 279 - 279
1 Mar 2013
Nam KW Choi S Nam U Kim S Kim HJ
Full Access

Melorheostosis is a very rare mesenchymal dysplasia of bone, characterized by sclerosing hyper-pigmentation appearances on the bone, may involve the adjacent soft tissues and lead to joint pain, limitation of joint motion and stiffness as a result of abnormal ossifications and soft tissue contractures, due to periarticular fibrosis. It is well known to tend to affect only one limb, but multifocal involvement, such as multiple limbs, spine and rib, has been extremely rarely reported. A variety of treatment options have been tried so far, none being specific surgical treatments.

Here we present a case of a 43-year-old man who sustained melorheostosis with multifocal involvement including the axial skeleton and a whole entire lower limb. He had painful swelling of his left lower limb and mainly complained of difficulty walking due to severe hip pain and knee stiffness, which persisted for 20 years and was aggravated during the last 5 years. Total hip arthropasty [Fig. 1] was done first, and then total knee arthroplasty [Fig. 2, 3] was performed. During operation, there were difficulties in bone cutting and implant insertion due to mixed pattern of hard sclerotic portion and osteoporotic portion despite complete synovectomy and sufficient soft tissue release. He was eventually free of pain during walking and able to walk without a crutch and joint motion of hip and knee was substantially improved after surgery.

We found that hip pain and contracture due to osteoarthritis and knee contracture secondary to multifocal melorheostosis could be successfully treated by total hip and knee arthroplasty. To the best of our knowledge, this is the first reporting the total joint arthroplasty performed in the patients with multifocal melorheostosis.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 268 - 268
1 Mar 2013
Moon Y Seo J Kim S Jang S Lee S
Full Access

Background and Purpose

Soft-tissue balancing is crucial in total knee arthroplasty, but proper release of medial collateral ligament is a challenging procedure. It has been well recognized that medial gap tends to be more tight than lateral gap in varus knees after surgery. The purpose of this study is to investigate the incidence and predictable factors of medial tibial bone remodeling following navigation-assisted total knee arthroplasty.

Materials and methods

One hundred and sixty-six consecutive patients (221 knees) who underwent navigation-assisted total knee arthroplasty and followed during a minimum of 1 year were included in this study. Radiographic examination including anteroposterior and lateral view of both knees were performed at a regular follow-up schedules of 6 weeks, 3 months, 6 months, 1 year and thereafter, annually after surgery. An independent investigator identified the presence of medial tibial bone remodeling at each follow-up. All information on potential factors affecting medial tibial remodeling were retrieved and classified into 2 types (patient- and surgery-related).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1499 - 1505
1 Nov 2012
Kim J Kasat NS Bae J Kim S Oh S Lim H

The purpose of this study was to measure the radiological parameters of femoral component alignment of the Oxford Phase 3 unicompartmental knee replacement (UKR), and evaluate their effect on clinical outcome. Multiple regression analysis was used to examine the relative contributions of the radiological assessment of femoral component alignment in 189 consecutive UKRs performed by a single surgeon. The American Knee Society scores were compared between groups, defined as being within or outside recommended tolerances of the position of the femoral component. For the flexion/extension position 21 UKRs (11.1%) lay outside the recommended limits, and for posterior overhang of the femoral component nine (4.8%) lay outside the range. The pre-operative hip/knee/ankle (HKA) angle, narrowest canal distance from the distal femoral entry point of the alignment jig and coronal entry-point position had significant effects on the flexion/extension position. Pre-operative HKA angle had a significant influence on posterior overhang of the femoral component. However, there was no significant difference in American Knee Society scores relative to the position of the femoral component.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 518 - 518
1 Sep 2012
Lee C Itoi E Kim S Lee J Jung K Lee S Suh K
Full Access

Introduction

Many literatures regarding more specific tests to diagnose the supraspinatus tendon injuries and the best rehabilitation methods to strengthen the supraspinatus have been published. However, conflicting results have been reported. 2-deoxy-2-[18F] fluoro-D-glucose (FDG) positron emission tomography (PET) has been recently used to assess skeletal muscle activities in various fields.

Purpose

To evaluate & compare the metabolic activities of deltoid & rotator cuff muscles after the full-can & empty-can exercises using PET-CT.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1071 - 1076
1 Aug 2012
Lim H Bae J Song S Kim S

Medium-term survivorship of the Oxford phase 3 unicompartmental knee replacement (UKR) has not yet been established in an Asian population. We prospectively evaluated the outcome of 400 phase 3 Oxford UKRs in 320 Korean patients with a mean age at the time of operation of 69 years (48 to 82). The mean follow-up was 5.2 years (1 to 10). Clinical and radiological assessment was carried out pre- and post-operatively. At five years, the mean Knee Society knee and functional scores had increased significantly from 56.2 (30 to 91) pre-operatively to 87.2 (59 to 98) (p = 0.034) and from 59.2 (30 to 93) to 88.3 (50 to 100) (p = 0.021), respectively. The Oxford knee score increased from a mean of 25.8 (12 to 39) pre-operatively to 39.8 (25 to 58) at five years (p = 0.038). The ten-year survival rate was 94% (95% confidence interval 90.1 to 98.0). A total of 14 UKRs (3.5%) required revision. The most common reason for revision was dislocation of the bearing in 12 (3%). Conversion to a total knee replacement was required in two patients who developed osteoarthritis of the lateral compartment.

This is the largest published series of UKR in Korean patients. It shows that the mid-term results after a minimally invasive Oxford phase 3 UKR can yield satisfactory clinical and functional results in this group of patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 128 - 133
1 Jan 2012
Kim S Agashe MV Song S Choi H Lee H Song H

Lengthening of the humerus is now an established technique. We compared the complications of humeral lengthening with those of femoral lengthening and investigated whether or not the callus formation in the humerus proceeds at a higher rate than that in the femur. A total of 24 humeral and 24 femoral lengthenings were performed on 12 patients with achondroplasia. We measured the pixel value ratio (PVR) of the lengthened area on radiographs and each radiograph was analysed for the shape, type and density of the callus. The quality of life (QOL) of the patients after humeral lengthening was compared with that prior to surgery. The complication rate per segment of humerus and femur was 0.87% and 1.37%, respectively. In the humerus the PVR was significantly higher than that of the femur. Lower limbs were associated with an increased incidence of concave, lateral and central callus shapes. Humeral lengthening had a lower complication rate than lower-limb lengthening, and QOL increased significantly after humeral lengthening. Callus formation in the humerus during the distraction period proceeded at a significantly higher rate than that in the femur.

These findings indicate that humeral lengthening has an important role in the management of patients with achondroplasia.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 446 - 446
1 Nov 2011
Oonishi H Kim S Oonishi H Kyomoto M Iwamoto M Ueno M
Full Access

In total hip arthroplasty (THA), one of concerned issues is osteolysis due to wear debris of ultra-high molecular weight polyethylene (PE) which often leads to aseptic loosening. Reduction of PE wear debris is essential to prevent osteolysis, and different bearing combination as well as improvement of the bearing material itself have been attempted. Hence alumina ceramics was introduced for THA, aiming to reduce PE wear debris. Ceramic on PE couple showed good results in clinical wear compared with metal on PE couples. Highly cross-linked PE (HXLPE) with gamma-ray or electron-beam irradiation followed by thermal treatment has also demonstrated a remarkably low wear in the previous in vitro studies. In in vivo studies, the wear of HXLPE acetabular cups against alumina ceramic femoral head was evaluated to compare with that of conventional PE cups against alumina ceramic femoral head.

The in vivo wear of 61 HXLPE cups (Aeonian; Kyocera Corp., Kyoto, Japan, currently Japan Medical Materials Corp., Osaka, Japan) against alumina ceramic femoral head of 28 mm in diameter with clinical use for 2.1–7.1 years (mean 5.6 years) and eight conventional PE cups against an alumina ceramic femoral head of 28 mm in diameter used for 18.7–23.3 years (mean 20.4 years) were examined by radiographic analysis with Vector Works 10.5. The in vivo wear of eight retrieved HXLPE cups with clinical use for 0.9–6.7 years (mean 2.9 years) and 14 retrieved conventional PE cups used for 16.0–28.0 years (mean 22.0 years) were examined by using a three-dimensional coordinate measuring machine. The worn surfaces of retrieved HXLPE and conventional PE cups were observed by a scanning electron microscope.

In the radiographic study, penetration rate of alumina head into HXLPE and conventional PE for the first 1 year were 0.24 mm/year and 0.34 mm/year respectively. One year later, the HXLPE showed significant lower penetration rate of 0.001 mm/year than the conventional PE penetration rate of 0.12 mm/year (p< 0.01). By the retrieval analysis, the mean penetration of retrieved HXLPE and conventional PE cups were 0.11 and 2.97 mm, and they were similar to the results by radiographic analysis. In the worn surface of the retrieved HXLPE cups used for around 1 year, machine marks were observed. In contrast, the worn surface of the retrieved HXLPE cups used for more than five years were smooth, and furthermore, in high magnification observation they had wear morphology different from conventional PE. These findings from this retrieval study suggest the penetration in the first 1 year detected by radiographic measurement was probably caused by creep deformation in bedding-in stage; and 1 year after, the penetration was probably caused mainly by wear.

By the radiographic analysis, HXLPE cups against alumina ceramic femoral head has a 99 % lower wear rate compared with conventional PE cups. Also, retrieved HXLPE cups against alumina ceramic femoral head exhibited lower wear compared with conventional PE cups. In conclusion, we expect that the HXLPE cup used with alumina ceramic femoral head has favorable wear properties in long-term clinical use.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 418 - 418
1 Nov 2011
Oonishi H Oonishi H Kim S Kyomoto M Iwamoto M Ueno M
Full Access

A consensus on total hip arthroplasty (THA) concluded that the major remaining issues of concern included the long-term fixation of the joint replacement, osteolysis due to poluethylene (PE) wear debris which often leads to aseptic loosening. Alumina ceramics had been extensively used in medicine, and we started using the alumina ceramic for THA bearing surface in hopes to reduce the PE debris. It was because alumina ceramics is advantageous for precision machining compared with metal materials, and its hardness is higher than that of metal materials. Also, to augment cement–bone bonding, we interposed hydroxyl apatite (HA) granules at the cement–bone interface, so called “Interface Bioactive Bone Cement (IBBC) technique”. HA granules (2–3 g) were smeared on the bone surface of the acetabulum and femur just before cementing. In this study, we evaluated 19–22 years clinical results of THA with alumina ceramic head combined with PE cup fixated IBBC technique.

Total 285 joints (212 patients) were implanted by one senior surgeon from January 1986 to December 1988, and 265 joints (192 patients) were traceable. Alumina ceramic femoral head of 28 mm in diameter and acetabular cup of the conventional PE sterilized with ethylene oxide gas were used in all patients. The PE cup and stem were fixed with IBBC technique in all cases. The presence of radiolucent line, loosening and osteolysis were observed using radiograph of the traceable cases. The locations of radiolucent lines were identified according to the zones described by DeLee and Charnley for acetabular cups and the zones described by Gruen et al. for femoral stems. The in vivo wear of 21 PE acetabular cups for 19.0–21.9 years (mean 20.3 years) was measured from the latest radiographs using computer assistant technique with Vector Works 10.5 software.

Features of the clinical radiograph images of the IBBC case were classified as follows: the radiolucent line represented “gap” between the HA layer and the cement; the loosening represented “opening” between the HA layer and the cement. For the quantitative analysis, we divided the surrounding bones of the THA into several zones as done in the previous studies. The “gap” appeared in zone 4 in three joints (1.4 %), in zone 3 in two joints (0.9 %) of acetabular cup. In femoral side, in zone 1 in four joints (1.8 %) in zone 7 in one joint (0.4 %). The “opening” appeared in three acetabular cup (1.4 %). Since no opening was appeared in zone 3 or zone 4, however, no re-operation was needed. Images of osteolysis were seen one in zone 1 (0.5 %), and one in zone 2 (0.5 %) in acetabular side and two in zone 1 (0.9 %) of the femur. The mean linear wear rate of PE acetabular cups was 0.13 mm/year.

The fixation to the bone by the IBBC technique has been maintained for long term. We think that the result was brought by the biological integration between bone and HA granules. In conclusion, this study has shown satisfactory results of the cemented THA with ceramic head combined with PE cup for 19–22 years.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 782 - 787
1 Jun 2011
Sun X Easwar TR Manesh S Ryu J Song S Kim S Song H

We compared the complications and outcome of tibial lengthening using the Ilizarov method with and without the use of a supplementary intramedullary nail. In a retrospective case-matched series assembled from 176 patients with tibial lengthening, we matched 52 patients (26 pairs, group A with nail and group B without) according to the following criteria in order of importance: 1) difference in amount of lengthening (± 2 cm); 2) percentage difference in lengthening (± 5%); 3) difference in patient’s age (± seven years); 4) aetiology of the shortening, and 5) level of difficulty in obtaining the correction. The outcome was evaluated using the external fixator index, the healing index and an outcome score according to the criteria of Paley. It was found that some complications were specific to group A or B respectively, but others were common to both groups.

The outcome was generally better in lengthenings with a nail, although there was a higher incidence of rectifiable equinus deformity in these patients.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 130 - 130
1 May 2011
Yoon S Kim J Kim S
Full Access

Background: Metal on metal articulation is known to reduce wear and subsequent development of osteolysis. However, long-term results of THA using metal on metal articulation is not well validated, especially in young patients.

Methods: Ninety-three THA were performed in 78 patients who were younger than 50 years of age at index surgery. The mean age of the patients was 37 years old. One patient (1 hip) had had a resection arthroplasty due to deep infection, 1 patient (1 hip) had performed stem revision because of periprosthetic fracture and 2 patients died before ten years follow-up and were excluded. Five patients (5 hips) were lost to follow-up before 10 years. Sixty-nine patients (84 hips) were available for complete clinical and radiographic analysis after minimum 10 years follow-up(range, 10 – 14 years).

Results: The mean preoperative Harris hip score of 49 points improved to 92 points at the time of last follow-up. Twenty hips(21.5%) showed variable degrees of osteolysis. Three patients underwent revision surgery because of focal pelvic osteolysis in one, aseptic loosening with extensive pelvic osteolysis of acetabular component in two. Three subsidence of femoral stem in other patients were identified.

Conclusions: At a minimum 10 years after THA using metal-on-metal articulation, it showed good results with regard to aseptic loosening in this group of young patients. However, relatively high rate of osteolysis in this articulation remains problematic and needs further investigation.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 139 - 139
1 Mar 2010
Lim Y Kwon S Sun D Kim S Kim H Kim Y
Full Access

The osseointegration of implants is related to the early interactions between osteoblastic cells and titanium surfaces. The behavior of osteoblast cells was compared on four different titanium surfaces in vitro and in vivo: machined, blasted, plasma spray and micro-arc oxidation.

X-ray diffraction and scanning electron microscope investigations were performed in order to assess the structure and morphology. Biologic and morphologic responses to the osteoblast cell lines (Saos-2) were then examined, using Promega proliferation assay, alkaline phosphatase activity, vβ3 integrin expression and cytoskeleton staining (Rhodamine-Phallodine). The analysis of gene expression for osteocalcin and collagen I was done through RT-PCR. In addition, differential histologic evaluation and interfacial strength at the bone-implant interfaces were then evaluated in the distal femur of four beagle dogs.