header advert
Results 41 - 60 of 62
Results per page:
Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 189 - 189
1 Mar 2008
Watanabe T Tomita T Yamazaki T Fujii M Sugamoto K Yoshikawa H
Full Access

The current study aimed to analyze in vivo kinematics during deep knee bending motion by subjects with fully congruent designed mobile-bearing total knee arthroplasty (TKA) allowing axial rotation and anterior/posterior (AP) gliding.

Twelve subjects were implanted with Dual Bearing-Knee (DBK, slot type: Finsbury, UK) prostheses. These implants include a mobile-bearing insert that is fully congruent with the femoral component throughout flex-ion and allows axial rotation and a 4–6 mm limited AP translation. Sequential fluoroscopic images were taken in the sagittal plane during loaded knee bending motion. In vivo kinematics of knee prostheses were computed accurately using a 2D/3D registration technique, which uses computer-assisted design models to reproduce the spatial position of metallic femoral and tibial components from calibrated single-view fluoroscopic images.

The average femoral component demonstrated 13.4° external axial rotation for 0° to 120° flexion. On average, the medial condyle moved anteriorly 6.2 mm for 0° to 100° flexion, then posteriorly 4.0 mm for 100° to 120° flexion. On average, the lateral condyle moved anteriorly 1.0 mm for0° to 40° flexion, then posteriorly 8.7 mm for 40° to 120° flexion. The average subject experienced a lateral pivot pattern from −5° to 60° flexion, a central pivot pattern from 60° to 100° flexion, and a rollback pattern which bilateral condyles moved backward from 100° to 120° of knee flexion.

Subjects with DBK mobile-bearing TKA in some-degree reproduced femoral external rotation during increasing knee flexion and bicondylar posterior rollback during terminal flexion, due to surrounding soft tissue structures. The geometry of replaced articular surfaces and mobility of the mobile-bearing insert produced lateral-to-central pivoting motions during the flexion cycle, a phenomenon not typically observed in normal knees. Using the current technique, we characterized the unique kinematics of fully congruent designed DBK mobile-bearing knee prostheses.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 752 - 760
1 Jun 2007
Yamada Y Toritsuka Y Horibe S Sugamoto K Yoshikawa H Shino K

We used three-dimensional movement analysis by computer modelling of knee flexion from 0° to 50° in 14 knees in 12 patients with recurrent patellar dislocation and in 15 knees in ten normal control subjects to compare the in vivo three-dimensional movement of the patella. Flexion, tilt and spin of the patella were described in terms of rotation angles from 0°. The location of the patella and the tibial tubercle were evaluated using parameters expressed as percentage patellar shift and percentage tubercle shift. Patellar inclination to the femur was also measured and patellofemoral contact was qualitatively and quantitatively analysed.

The patients had greater values of spin from 20° to 50°, while there were no statistically significant differences in flexion and tilt. The patients also had greater percentage patellar shift from 0° to 50°, percentage tubercle shift at 0° and 10° and patellar inclination from 0° to 50° with a smaller oval-shaped contact area from 20° to 50° moving downwards on the lateral facet.

Patellar movement analysis using a three-dimensional computer model is useful to clearly demonstrate differences between patients with recurrent dislocation of the patella and normal control subjects.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 746 - 751
1 Jun 2007
Yamada Y Toritsuka Y Yoshikawa H Sugamoto K Horibe S Shino K

We investigated the three-dimensional morphological differences of the articular surface of the femoral trochlea in patients with recurrent dislocation of the patella and a normal control group using three-dimensional computer models.

There were 12 patients (12 knees) and ten control subjects (ten knees). Three-dimensional computer models of the femur, including the articular cartilage, were created. Evaluation was performed on the shape of the articular surface, focused on its convexity, and the proximal and mediolateral distribution of the articular cartilage of the femoral trochlea. The extent of any convexity, and the proximal distribution of the articular cartilage, expressed as the height, were shown by the angles about the transepicondylar axis. The mediolateral distribution of the articular cartilage was assessed by the location of the medial and lateral borders of the articular cartilage.

The mean extent of convexity was 24.9° sd 6.7° for patients and 11.9° sd 3.6° for the control group (p < 0.001). The mean height of the articular cartilage was 91.3° sd 8.3° for the patients and 83.3° sd 7.7° for the control group (p = 0.03), suggesting a wider convex trochlea in the patients with recurrent dislocation of the patella caused by the proximally-extended convex area. The lateral border of the articular cartilage of the trochlea in the patients was more laterally located than in the control group.

Our findings therefore quantitatively demonstrated differences in the shape and distribution of the articular cartilage on the femoral trochlea between patients with dislocation of the patella and normal subjects.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 490 - 494
1 Apr 2007
Arimitsu S Murase T Hashimoto J Oka K Sugamoto K Yoshikawa H Moritomo H

We have measured the three-dimensional patterns of carpal deformity in 20 wrists in 20 rheumatoid patients in which the carpal bones were shifted ulnarwards on plain radiography. Three-dimensional bone models of the carpus and radius were created by computerised tomography with the wrist in the neutral position. The location of the centroids and rotational angle of each carpal bone relative to the radius were calculated and compared with those of ten normal wrists.

In the radiocarpal joint, the proximal row was flexed and the centroids of all carpal bones translocated in an ulnar, proximal and volar direction with loss of congruity. In the midcarpal joint, the distal row was extended and congruity generally well preserved. These findings may facilitate more positive use of radiocarpal fusion alone for the deformed rheumatoid wrist.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 455 - 460
1 Apr 2007
Sugano N Nishii T Miki H Yoshikawa H Sato Y Tamura S

We have developed a CT-based navigation system using infrared light-emitting diode markers and an optical camera. We used this system to perform cementless total hip replacement using a ceramic-on-ceramic bearing couple in 53 patients (60 hips) between 1998 and 2001. We reviewed 52 patients (59 hips) at a mean of six years (5 to 8) postoperatively. The mid-term results of total hip replacement using navigation were compared with those of 91 patients (111 hips) who underwent this procedure using the same implants, during the same period, without navigation. There were no significant differences in age, gender, diagnosis, height, weight, body mass index, or pre-operative clinical score between the two groups. The operation time was significantly longer where navigation was used, but there was no significant difference in blood loss or navigation-related complications. With navigation, the acetabular components were placed within the safe zone defined by Lewinnek, while without, 31 of the 111 components were placed outside this zone. There was no significant difference in the Merle d’Aubigne and Postel hip score at the final follow-up. However, hips treated without navigation had a higher rate of dislocation. Revision was performed in two cases undertaken without navigation, one for aseptic acetabular loosening and one for fracture of a ceramic liner, both of which showed evidence of neck impingement on the liner. A further five cases undertaken without navigation showed erosion of the posterior aspect of the neck of the femoral component on the lateral radiographs. These seven impingement-related mechanical problems correlated with malorientation of the acetabular component. There were no such mechanical problems in the navigated group.

We conclude that CT-based navigation increased the precision of orientation of the acetabular component and control of limb length in total hip replacement, without navigation-related complications. It also reduced the rate of dislocation and mechanical problems related to impingement.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 209 - 209
1 May 2006
Kuriyama K Hashimoto J Fujii M Murase T Tsuboi H Myoui A Yoshikawa H
Full Access

Background: Juxta-articular intraosseous cystic lesions (JAICL) are common lesion in patients with rheumatoid arthritis (RA) and could cause spontaneous pathological fractures and extensive joint destruction. Although surgical treatment is well indicated for benign bone tumour such as solitary bone cyst, RA induced JAICL have been rarely treated surgically because of following reasons. The first is the possible re-absorption of grafted bone due to disease progression. The second is donor site problem of iliac bone autografting. The third is limitation of autograft for possible operations in the future. The fourth is the lack of bone graft substitutes with good osteoconductivity. We have developed the interconnected porous calcium hydroxyapatite ceramic (IP-CHA) with excellent osteoconductivity. The IP-CHA achieved major incorporation with host bone much more rapid than the other porous calcium hydroxyapatite ceramics. We evaluated the feasibility and effectiveness of curettage and packing with the IP-CHA for the treatment of JAICL in RA patients.

Methods: Nine JAICL in 7 RA patients were treated by curettage and packing with IP-CHA. Eight lesions were impending pathological fractures. Two were male and five were female, the average age of operation was 57.8 years (range, forty-nine to seventy-two years). Follow-up assessment was based on final radiography at an average of 10.9 months after surgery (range, five to seventeen months). The expansion of the cystic lesions around the implanted IP-CHA and the re-absorption of the IP-CHA itself, which means erosion or increasing porosity of implanted IP-CHA, were assessed on the basis of the radiographies at just after operation and final follow up.

Results: The locations were as follows: distal radius, 6 lesions; distal ulna, 1; proximal tibia, 1; distal fibula, 1. No lesions showed the re-absorption of implanted IP-CHA itself. One of 9 lesions showed out-expansion of radiolucent area around the implanted IP-CHA without re-absoption of IP-CHA itself at the final follow-up. There were no postoperative fractures as complication.

Conclusions: These results suggested that surgical intervention with the IP-CHA could be useful for prevention of pathological fractures due to arthritis related JAICL. The efficacies of this technique might be augmented by amelioration of disease activity with concomitant drug therapy including biologics, since there was one case with out-expansion of cystic lesions in RA patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 719 - 725
1 Jul 2004
Matsumine A Myoui A Kusuzaki K Araki N Seto M Yoshikawa H Uchida A

We reviewed the results of 51 patients with benign bone tumours treated by curettage and implantation of calcium hydroxyapatite ceramic (CHA). The mean follow-up was 11.4 years (10 to 15.5). Post-operative fractures occurred in two patients and three had local recurrences; three had slightly limited movement of the adjacent joint and one had mild osteoarthritis. There were no allergic or neoplastic complications. In all cases, radiographs showed that the CHA was well incorporated into the host bone.

Statistical analysis showed that absorption of the implanted CHA was greater in males (odds ratio, 6.2; 95% CI, 1.6 to 23.7) and younger patients (odds ratio, 0.6 for increase in age of 10 years; 95% CI, 0.91 to 0.99). However, the implanted CHA was not completely absorbed in any patient.

We conclude that CHA is a useful and safe bone substitute for the treatment of benign bone tumours.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 607 - 612
1 May 2004
Asano N Yamakazi T Seto M Matsumine A Yoshikawa H Uchida A

We investigated the rates of expression of bone morphogenetic protein-2 (BMP-2) in 29 adult patients with high-grade malignant fibrous histiocytoma of soft tissue, using the BMP-2-specific monoclonal antibody, AbH3b2/17, and found that they ranged from 1.9% to 78.9%. The survival at five years of the groups expressing high (≥30%) and low (< 30%) levels of BMP-2 was 85.7% and 36.3%, respectively. Multivariable analysis showed that only BMP-2 had prognostic significance for continuous disease-free survival and for overall survival (p < 0.05). Our findings indicate that over-expression of BMP-2 in malignant fibrous histiocytoma of soft tissue is the most reliable prognostic indicator of the parameters assessed.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 409 - 409
1 Apr 2004
Sakai T Sugano N Ohzono K Lee S Nishii T Miki H Haraguchi K Yoshikawa H
Full Access

Introduction: The purpose of this study is to evaluate the clinical and radiogra phic outcome of patients with secondary osteoarthritis of the hip, who underwent custom-made cementless THA.

Methods: Between January 1994 and June 1997, 98 prim ary cementless custom-made THA’s were performed in 76 patients with secondary osteoarthritis and reviewed at mean 6 years follow-up (range: 4 – 7.5 years). Nine patients had a previous femoral osteotomy. There were 69 females and seven males. The mean age at operation was 54 years (40 – 73 years). Custom-made, 125 mm-long, titanium femoral components with blasted surface were fabricated based on the computerized tomography.

Results: The mean Harris Hip Score improved from 43 to 95 points. 97 patients (99%) had more than 80 points for total score, and 2 patients (2%) had thigh pain at the latest follow-up. Radiographically, 86 hips (87%) showed obviously extensive bone ongrowth onto the middle part of the stem while 8 hips (9%) showed stable fibrous fixation. Four hips (4%) were unstable: more than 2 mm subsidence in 2 hips and more than 2 degrees varus migration in 2 hips. Of these 4 hips, 2 had intraoperative cracks of the poximal femur and 2 had varus positioning of the stem.

Discussion and conclusion: Cementless THA has been advocated to enhance fit and fill of variable hip geometry. However, some clinical studies failed to show that custom implants significantly improve clinical success or implant longevity because their surface finish was not optimal. Custom-made titanium femoral components with blasted surface showed good clinical results. The reasons for radiolographical failures were because of intraoperative technical errors and these might be derived from 125 mm-long stem with maximum canal fill. A shorter stem may be an option because it may improve the feasibility of stem insertion and the distal fill.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 185 - 189
1 Mar 2004
Kishida Y Sugano N Nishii T Miki H Yamaguchi K Yoshikawa H

We investigated the effect of the Birmingham hip resurfacing (BHR) arthroplasty on the bone mineral density (BMD) of the femur. A comparative study was carried out on 26 hips in 25 patients. Group A consisted of 13 patients (13 hips) who had undergone resurfacing hip arthroplasty with the BHR system and group B of 12 patients (13 hips) who had had cementless total hip arthroplasty with a proximal circumferential plasma-spray titanium-coated anatomic Ti6A14V stem. Patients were matched for gender, state of disease and age at the time of surgery. The periprosthetic BMD of the femur was measured using dual-energy x-ray absorptiomentry of the Gruen zones at two years in patients in groups A and B.

The median values of the BMD in zones 1 and 7 were 99% and 111%, respectively. The post-operative loss of the BMD in the proximal femur was significantly greater in group B than in group A. These findings show that the BHR system preserves the bone stock of the proximal femur after surgery.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 148 - 148
1 Feb 2004
Nishii T Sugano N Miki H Takao M Koyama T Nakamura N Yoshikawa H
Full Access

Introduction: Progression of collapse in osteonecrosis of the femoral head (ONFH) is greatly influenced by repair reactions, especially bone resorptive activity. This study was performed to test if systemic alendronate treatment, a potent inhibitor of osteoclast activity, can prevent the development of collapse in ONFH.

Materials and Methods: Daily administration of oral alendronate (5mg/day) was started in 14 hips in 11 patients with ONFH (Alendronate group). At the beginning of the study (3, 6, 12 months), plain radiographs, T1-weighted MR imaging, and biochemical makers of osteoclast activity (N-telopeptide of type-I collagen) and osteoblast activity (Bone-specific alkaline phosphatase), were examined. At 12 months, MR imaging was repeated. Eleven hips in 6 patients with ONFH who did not receive alendronate administration were considered as the control group.

Results: There was no significant difference with respect to gender distribution, etiology factors, initial ARCO stages, and extent of necrosis in the two groups. In the alendronate group, there was an early decrease of osteoclast activity at 3 months, with a decrease to 62% at 12 months, while the decrease of osteoblast activity was smaller with 80% at 12 months. Development of collapse was observed in 4 of the 11 hips (36%) in the control group, and in none of the 14 hips in the alendronate group. There was a significant difference of collapse development between the two groups (p=0.026, Mann-Whitney U-test). Signal change on serial MR images was observed in 5 of 9 hips (56%) in the control group, with only one of 9 hips (11%) in the alendronate group.

Discussion: The low incidence of signal change on serial MR images may reflect the decrease of repair activity in the alendronate group. The present study was the first clinical trial to show that alendronate has a significant preventive effect of collapse development in patients with osteonecrosis of the femoral head.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 145 - 145
1 Feb 2004
Sakai T Ohzono K Lee S Sugano N Nishii T Miki H Takao M Koyama T Morimoto D Yoshikawa H
Full Access

Introduction: In order to investigate the relationship between the degeneration of the acetabular cartilage and the radiological staging of osteonecrosis of the femoral head, the following study was performed.

Materials and Methods: Acetabular cartilage with sub-chondral bone was taken from the superior dome from 34 hips from 30 patients undergoing total hip arthroplasty due to osteonecrosis of the femoral head. The specimens were stained with hematoxylineosin and safranin-O, and were evaluated as to the thinning of cartilage, fibrillation, clefts, and proliferation of chondrocytes. There were 18 females and 12 males with an average age of 49 years. We used the radiological staging system proposed by the working group of the Specific Disease Investigation Committee under the auspices of the Japanese Ministry of Health, Labor and Welfare. There were eight hips in stage IIIA disease (collapse of the femoral head less than 3 mm), 19 hips in stage IIIB disease (collapse 3 mm or greater), and seven stage IV disease hips.

Results: All 34 specimens showed histological abnormalities. In eight stage IIIA hips, six hips were mild and two were moderate histological degeneration. In 19 stage IIIB hips, five hips were mild, six were moderate, and eight had severe arthrosis. Seven stage IV hips had severe arthrosis.

Discussion: Although the radiographs cannot demonstrate early degeneration of cartilage, degenerative changes were present in all stage III hips. Histological degenerative changes in stage IIIB hips were more severe than those in stage IIIA hips. These findings should be kept in mind in treating patients with osteonecrosis of the femoral head.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 145 - 145
1 Feb 2004
Takao M Sugano N Nishii T Masumoto J Miki H Sato Y Tamura S Yoshikawa H
Full Access

Introduction: There is controversy over whether the lesions of osteonecrosis of the femoral head (ONFH) will spontaneously decrease. This study reports a longitudinal study of lesion volume using high-resolution serial MRI and recently developed techniques for image registration to realign serial images.

Materials and Methods: Baseline and follow-up (minimum one year later) MRI scans were carried out on 15 patients (18 hips). Accurate subvoxel registration was performed and subtraction images were produced to reveal areas of regional necrotic lesion change. Volume-to-femoral head ratio (VFR) was calculated to normalize the measured volume to the total femoral head volume.

Results: Three of 18 hips showed spontaneous reductions in the size of the lesions. They were all related to steroid use and were within one year after initial steroid treatment The mean volume decrease of these 3 hips was 3.4 ± 2.0 cm3 (SD) and its VFR was 6.8 ± 3.1 % (SD). Mean necrotic lesion volumes at baseline of decreasing lesions and unchanged lesions were 4.6 ± 2.5 cm3 (VFR, 9.1 ± 3.9 %) and 7.5 ± 5.5 cm3 (VFR, 16.7 ± 12.4 %), respectively.

There was no statistically significant difference in baseline lesion volume between decreasing lesions and unchanged lesions.

Discussion: In conclusion, some early lesions within one year after onset can decrease in size on MRI, regardless their size at baseline.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 80 - 80
1 Jan 2003
Owaki H Hashimoto J Hayashida K Hashimoto H Ochi T Yoshikawa H
Full Access

[Objectives] Hallux valgus, dorsal sublaxation or dislocation of metatarsophalangeal joints and clawing of the lateral toes are seen frequently in patients with rheumatoid arthritis (RA). Resection arthroplasty of the metatarsophalangeal joints (MTP joints) are widely used to correct these forefoot deformities and the clinical results are almost good. However lateral toes tend to displace dorsally and painful callosity tends to recur. We used the metatarsal shortening offset osteotomy for shortening and dorsal/medial displacement of the prominent metatarsal head. In this report, we introduce the surgical techniques of shortening offset osteotomy and postoperative changes of plantar pressure measured with F-scan system (Tekscan, Inc. ), and review the short term result during 1 to 4 year follow-up.

[Materials and Methods] This study involved 26 feet of 18 patients with RA which were performed with the metatarsal osteotomy for lateral toes and followed more than 1 year (average follow-up 29 months, range 14–46 months). The average age of the 17 women and 1 man was 61 years (range, 51–77 years). The mean duration from the onset of RA to operation on the forefoot was 17 years (range, 7–42 years). Skin incision was placed on the dorsum of the foot and the extensor digitorum brevis and longus were severed (or elongated). After reposition of MTP joint, transverse osteotomy of distal fifth of the lateral metatarsal bone was performed with resection of few millimeters length metaphysial bone. Cortical bone of the distal end of the proximal stump was chiseled into a small rod between two ditches with rongeur and then the rod was put into medullary canal mortise of distal stump. This procedure make offset shift of metatarsal head medially or dorsally. Swanson implant arthroplasty, distal osteotomy was performed on the great toe. Postoperative clinical and radiological results were evaluated with AOFAS rating system. We measured dynamic plantar pressure before and one year after operation in one representative case.

[Results] At the time of follow-up, the mean AOFAS score was 80 points (59–95) and the mean pain score was 36 points. The recurrence of painful callosity was one case. Nevertheless, the range of motion of the MTP joint remained low: 30 degrees and less in 16 feet (62%) including 3 bony ankylosis of MTP joints. There was no nonunion case. [Discussion]

Resection arthroplasty has been accepted as the treatment of choice for forefoot deformities in RA patients. Recent advance of drug therapy against RA encouraged us to preserve the joint in correction of forefoot deformities. Our technique aimed at preservation of the function of the MTP joints and is suitable for mild deformities in which only one or two rays are involved. Furthermore it is easy to correct the deformity of spray foot and reduce the plantar prominence of metatarsal head. This study revealed the good clinical result in short term follow-up. Although the long term result must to be waited, this method is one of recommendable options for RA patients with forefoot deformities.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 28 - 28
1 Jan 2003
Shimada K Saito M Nakashima T Wigderowitz C Rowley D Namba J Akita S Yoshikawa H
Full Access

We developed a new type of bioactive bone cement, CAP (Hydroxyapatite composite resin; composed of 77% w/w hydroxyapatite granules and bisphenol-A glycidyl methacrylate-based resin) for bony defect filling. Elastic modulus of CAP is similar to a cortical bone, while it is injectable before hardening and physiologically bonding with bone in 4 to 8 weeks. We present a new method of treatment for unstable Colles’ fracture with this material in clinical use.

Experimental comminuted Colles’ fracture was produced in three fresh frozen cadavara. Fracture was reduced and fixed percutaneously with K-wires. 4.5mm drill hole was opened on the radial cortex 3cm proximal to the fracture site. Comminuted fragments were pushed-up to the subchondral area with a blunt rod and CAP was injected through the same way. After cement hardening, K-wires were removed. X-ray photos were examined before fracture, after fracture and after reconstruction with CAP, in order to evaluate the shape of the radius. CT was examined to evaluate the placement of CAP.

Radiographic parameters of radii were well recovered after reconstruction with CAP. Over correction of the radial length was observed in one bone but good reduction was generally achieved (Table). This means realignment of the distal radioulnar joint, which results in good outcome clinically. In transverse section of CT, 41 to 69% (average 55%) of subchondral area was filled with CAP. Filling of CAP was better in an osteoporotic bone. These results show the usefulness of this material for treatment of unstable Colles’ fracture especially in osteoporotic patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 996 - 1000
1 Sep 2001
Haraguchi K Sugano N Nishii T Miki H Oka K Yoshikawa H

We report two cases of surface deterioration of a zirconia ceramic femoral head associated with phase transformation after total hip arthroplasty. One head was retrieved at revision due to recurrent dislocation after six years and the other because of failure of the locking mechanism of the polyethylene liner after three years. The monoclinic content of the zirconia ceramics rose from 1% to about 30% on the surface of the heads. SEM revealed numerous craters indicating extraction of the zirconia ceramics at the surface. Surface roughness increased from an initial value of 0.006 3m up to 0.12 3m. This is the first report to show that phase transformation of zirconia ceramics causes deterioration of the surface roughness of the head in vivo after total hip arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 659 - 662
1 Jul 2001
Kudawara I Yoshikawa H Araki N Ueda T

We present three cases of intramuscular haemangioma adjacent to bone in the lower limb. All patients had local pain during the third decade. Plain radiographs showed an irregular or hypertrophic periosteal reaction on the shaft of the fibula and an intramuscular mass adjacent to the bone with inhomogenous high signal intensity on MRI. These lesions mimic periosteal or parosteal tumours.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 548 - 552
1 Jul 1997
Yoshikawa H Ueda T Mori S Araki N Kuratsu S Uchida A Ochi T

We reviewed 277 patients with soft-tissue sarcoma (STS) treated between 1975 and 1995 to study the incidence, distribution, time of appearance, and radiological findings of skeletal metastases. Of these, 28 (10.1%) had metastases within a mean period of 18.6 months after admission.

The incidence of skeletal metastases differed among the histological subtypes of sarcoma; alveolar soft-part sarcoma, dedifferentiated liposarcoma, angiosarcoma, and rhabdomyosarcoma tended to show higher incidences. The regional bones close to the primary tumour were affected in 13 (46.4%) of the 28 patients, and the axial bones in 18 (64.3%). Radiologically, the metastatic bony lesions predominantly showed osteolytic changes, and there were pathological fractures in 21 of 44 lesions.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 553 - 557
1 Jul 1997
Ueda T Yoshikawa H Mori S Araki N Myoui A Kuratsu S Uchida A

We have investigated the significance of local recurrence on survival in 173 patients with localised soft-tissue sarcomas of the limbs and of the trunk.

The overall survival rates at five and ten years were 75.2% and 68.0%, respectively. After definitive surgery at our hospitals, there was local recurrence in 25 patients (14.5%). After inadequate operations elsewhere, there was a higher incidence of late local recurrence (28.3%), in comparison with those with primary tumours treated by us (9.0%), or patients referred to us immediately after inadequate surgery elsewhere (10.2%). Because of small numbers these differences in the survival rates were not statistically significantly different.

Univariate survival analysis showed that local recurrence after definitive surgery (p = 0.006) together with the histological grade (p = 0.0002), the size of the tumour (p = 0.002), its depth in relation to deep fascia (p = 0.003), and the surgical margin (p = 0.0001) were the significant prognostic factors. Local recurrence at the initial presentation did not affect survival. Multivariate analysis showed that local recurrence after definitive surgery also lost its apparent prognostic significance.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 2 | Pages 266 - 269
1 Mar 1993
Shinto Y Uchida A Yoshikawa H Araki N Kato T Ono K

We report the case of a 19-year-old man with inguinal lymphadenopathy caused by metallic debris from the loosening of a prosthesis inserted after tumour resection. Large amounts of wear debris may be released from such massive replacements, and surgeons should be aware of the range of possible adverse effects.