header advert
Results 21 - 40 of 60
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 205 - 211
1 Feb 2020
Shao X Shi LL Bluman EM Wang S Xu X Chen X Wang J

Aims

To evaluate the donor site morbidity and tendon morphology after harvesting whole length, full-thickness peroneus longus tendon (PLT) proximal to the lateral malleolus for ligament reconstructions or tendon transfer.

Methods

A total of 21 eligible patients (mean age 34.0 years (standard deviation (SD) 11.2); mean follow-up period 31.8 months (SD 7.7), and 12 healthy controls (mean age, 26.8 years (SD 5.9) were included. For patients, clinical evaluation of the donor ankle was performed preoperatively and postoperatively. Square hop test, ankle strength assessment, and MRI of distal calf were assessed bilaterally in the final follow-up. The morphological symmetry of peroneal tendons bilaterally was evaluated by MRI in healthy controls.


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1489 - 1497
1 Dec 2019
Wang J Ma H Chou TA Tsai S Chen C Wu P Chen W

Aims

The aim of this meta-analysis was to compare the outcome of total elbow arthroplasty (TEA) undertaken for rheumatoid arthritis (RA) with TEA performed for post-traumatic conditions with regard to implant failure, functional outcome, and perioperative complications.

Materials and Methods

We completed a comprehensive literature search on PubMed, Web of Science, Embase, and the Cochrane Library and conducted a systematic review and meta-analysis. Nine cohort studies investigated the outcome of TEA between RA and post-traumatic conditions. The preferred reporting items for systematic reviews and meta-analysis (Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)) guidelines and Newcastle-Ottawa scale were applied to assess the quality of the included studies. We assessed three major outcome domains: implant failures (including aseptic loosening, septic loosening, bushing wear, axle failure, component disassembly, or component fracture); functional outcomes (including arc of range of movement, Mayo Elbow Performance Score (MEPS), and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire), and perioperative complications (including deep infection, intraoperative fracture, postoperative fracture, and ulnar neuropathy).


Bone & Joint Research
Vol. 8, Issue 11 | Pages 526 - 534
1 Nov 2019
Yang C Wang J Yin Z Wang Q Zhang X Jiang Y Shen H

Objectives

The optimal protocol for antibiotic loading in the articulating cement spacers for the treatment of prosthetic joint infection (PJI) remains controversial. The objective of the present study was to investigate the effectiveness of articulating cement spacers loaded with a new combination of antibiotics.

Methods

A retrospective cohort study involving 114 PJI cases treated with implantation of an articulating cement spacer between 2005 and 2016 was performed. The treatment outcomes of the conventional protocol (i.e. gentamicin and vancomycin (GV protocol)) were compared with those reported using the sophisticated antibiotic-loading protocol (i.e. vancomycin, meropenem, and amphotericin (VMA protocol)).


Bone & Joint Research
Vol. 8, Issue 11 | Pages 526 - 534
1 Nov 2019
Yang C Wang J Yin Z Wang Q Zhang X Jiang Y Shen H

Objectives

The optimal protocol for antibiotic loading in the articulating cement spacers for the treatment of prosthetic joint infection (PJI) remains controversial. The objective of the present study was to investigate the effectiveness of articulating cement spacers loaded with a new combination of antibiotics.

Methods

A retrospective cohort study involving 114 PJI cases treated with implantation of an articulating cement spacer between 2005 and 2016 was performed. The treatment outcomes of the conventional protocol (i.e. gentamicin and vancomycin (GV protocol)) were compared with those reported using the sophisticated antibiotic-loading protocol (i.e. vancomycin, meropenem, and amphotericin (VMA protocol)).


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1107 - 1114
1 Sep 2019
Uy M Wang J Horner NS Bedi A Leroux T Alolabi B Khan M

Aims

The aim of this study was to evaluate the differences in revision and complication rates, functional outcomes, and radiological outcomes between cemented and press-fit humeral stems in primary anatomical total shoulder arthroplasty (TSA).

Materials and Methods

A comprehensive systematic review and meta-analysis was conducted searching for studies that included patients who underwent primary anatomical TSA for primary osteoarthritis or rheumatoid arthritis.


Objectives

Adult mice lacking the transcription factor NFAT1 exhibit osteoarthritis (OA). The precise molecular mechanism for NFAT1 deficiency-induced osteoarthritic cartilage degradation remains to be clarified. This study aimed to investigate if NFAT1 protects articular cartilage (AC) against OA by directly regulating the transcription of specific catabolic and anabolic genes in articular chondrocytes.

Methods

Through a combined approach of gene expression analysis and web-based searching of NFAT1 binding sequences, 25 candidate target genes that displayed aberrant expression in Nfat1-/- AC at the initiation stage of OA, and possessed at least four NFAT1 binding sites in the promoter of each gene, were selected and tested for NFAT1 transcriptional activities by chromatin immunoprecipitation (ChIP) and promoter luciferase reporter assays using chondrocytes isolated from the AC of three- to four-month-old wild-type mice or Nfat1-/- mice with early OA phenotype.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 102 - 102
1 Feb 2017
Dong N Wang J Chen C Wang A Zhou Y
Full Access

Introduction

Self tapping bone screw has been widely used in the fixation of Arthroplasty implants and bone graft. But the unwanted screw or driver breakage can be a direct result of excessive driving torque due to the thread cutting resistance. Previous studies showed that bone drill bit cutting rake angle was a critical factor and was inversely related to the bone cutting efficiency.1, 2, 3, 4 (Figure 1) However to date there was no data for how the rake angle could influence the performance of self tapping bone screw. The purpose of this study was to investigate the torque generated by the self tapping cortical screw in simulated bone insertion as a function of the screw tip cutting flute rake angle.

Methods

Two 5 mm thick BM5166 polyurethane block were stacked together and drilled through with 2.5mm diameter holes. Five 30mm long 3.5 mm diameter Ti6AL4V alloy self tapping cortical screws with 0°rake angle cutting flutes (Figure 2) were inserted in the holes and driven by the spanner attached to the test machine (Z5.0TN/TC-A-10) with a displacement control of 3 revolutions/min and 30N constant axial loading. The screws were driven into the stacked polyurethane block for 8mm depth. The maximum driving torque was recorded. Procedure was repeated for five same screws but with 7° rake angle cutting flutes. (Figure 2) The driving torqueses were compared. Student t test was performed with confidence level of 95% was assumed.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 34 - 34
1 Jan 2017
Kuo M Hong S Lu T Wang J
Full Access

Posterior cruciate ligament deficiency (PCLD) leads to structural and proprioceptive impairments of the knee, affecting the performance of daily activities including obstacle-crossing. Therefore, identifying the biomechanical deficits and/or strategies during this motor task would be helpful for rehabilitative and clinical management of such patients. A safe and successful obstacle-crossing requires stability of the body and sufficient foot clearance of the swing limb. Patients with PCLD may face demands different from normal when negotiating obstacles of different heights. The objective of this study was thus to identify the biomechanical deviations/strategies of the lower limbs in unilateral PCLD during obstacle-crossing using motion analysis techniques.

Twelve patients with unilateral PCLD and twelve healthy controls participated in the current study with informed written consent. They were asked to walk and cross obstacles of heights of 10%, 20% and 30% of their leg lengths at self-selected speeds. The PCLD group was asked to cross the obstacles with each of the affected and unaffected limb as the leading limb, denoted as PCLD-A and PCLD-U, respectively. The kinematic and kinetic data were measured with a 7-camera motion analysis system (Vicon, Oxford Metrics, U.K.) and two force plates (AMTI, U.S.A.). The angles of the stance and swing limbs (crossing angles) and the moments of the stance limbs (crossing moments) for each joint in the sagittal plane when the leading limb was above the obstacle were calculated for statistical analysis. A 3 by 2, 2-way mixed-model analysis of variance with one between-subject factor (PCLD-A vs. Control, and PCLD-U vs. Control) and one within-subject factor (obstacle height) was performed (α=0.05). Paired t-test was used to compare the variables between PCLD-A and PCLD-U (α=0.05). SAS version 9.2 was used for all statistical analysis.

When the leading toe was above the obstacle, the PCLD group showed significantly greater hip flexion in the swing limb but decreased dorsiflexion in the stance limb, both in PCLD-A and PCLD-U (P<0.05). Greater knee flexion and greater ankle dorsiflexion were found in the leading limb in PCLD-A (P<0.05). Meanwhile, the PCLD group showed significantly decreased ankle plantarflexor but increased knee extensor crossing moments in the stance limb compared with the Control (P<0.05). None of the calculated variables were found to be significantly different between PCLD-A and PCLD-U (P>0.05).

When crossing the obstacle, patients with PCLD reduced ankle plantarflexor moments that were mainly produced by the gastrocnemius. This may help reduce the posterior instability of the affected knee. Greater knee extensor crossing moments may also help reduce the posterior instability of the standing knee when the leading toe was above the obstacle.

The changed joint kinetics as a result of PCLD were not only seen on the affected side but also on the unaffected side during obstacle-crossing. This symmetrical pattern may be necessary in performing functional activities that may require either the affected side or the unaffected side leading. These results suggest that rehabilitative intervention, including muscular strengthening, on both affected and unaffected sides are necessary in patients with unilateral PCLD.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 149 - 149
1 May 2016
Lee B Wang J Kim G
Full Access

Introduction

Medial open wedge high tibial osteotomy (HTO) is a generally accepted surgical method for medial unicompartmental osteoarthritis with varus malalignment of the lower extremity. However, several authors have suggested the possibility of unintentional secondary changes during open wedge HTO, which include posterior tibial slope angle (PTS) change, tibial rotation change and medial–lateral slope change of the knee joint line, may influence knee kinematics and produce poor clinical outcomes. We sought to analyze postoperative changes in three-dimensional planes using a virtual wedge osteotomy 3D model. Pre- and post-operative changes in the medial proximal tibial angle (MPTA) in the coronal plane, posterior tibial slope (PTS) in the sagittal plane, and axial tibial rotation were measured as dependent variables. And this study was attempted to determine their mutual relationships and to clarify which independent variables, including hinge axis angle and gap ratio, affect tibial rotation change and PTS change by applying the identified hinge position.

Method

A total of 17 patients with 19 knees underwent HTO and were evaluated with 3D-CT before and after surgery. A 3D model was constructed by applying reverse engineering software.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 121 - 121
1 May 2016
Dong N Wang J Chen C Wang A Zhou Y
Full Access

Objective

The purpose of this study was to investigate how rim poly locking scallop cutting depth could affect the rigidity of acetabular cup.

Materials and Methods

(11) generic FEA models including (5) 50mm OD Ti6Al4VELI hemispherical acetabular shells with thicknesses of 3.0, 3.5, 4.0, 4.5 and 5.0mm, and (6) 4mm thick hemispherical shells with standard rim poly indexing scallops varied in cutting depths from inner diameter of the cup in 1.0, 1.5, 2.0, 2.5, 3.0 and 3.5mm. All cups were analyzed in ANSYS® Workbench™ FEA software with a loading condition of 2000N applied to the cup rim per V15 ISO/TC 150/SC 4 N. Verification was carried out by the physical test of a same generic Ti6Al4VELI 50mmOD and 5mm thick solid hemispherical shell under 2000N rim directed load. The cup deformation was compared with FEA results. The maximum deformation of FEA scalloped cups were compared with that of solid hemispherical cups with different shell thickness.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 672 - 678
1 May 2016
Zhang X Zhang Z Wang J Lu M Hu W Wang Y Wang Y

Aims

The aim of this study is to introduce and investigate the efficacy and feasibility of a new vertebral osteotomy technique, vertebral column decancellation (VCD), for rigid thoracolumbar kyphotic deformity (TLKD) secondary to ankylosing spondylitis (AS).

Patients and Methods

We took 39 patients from between January 2009 and January 2013 (26 male, 13 female, mean age 37.4 years, 28 to 54) with AS and a TLKD who underwent VCD (VCD group) and compared their outcome with 45 patients (31 male, 14 female, mean age 34.8 years, 23 to 47) with AS and TLKD, who underwent pedicle subtraction osteotomy (PSO group), according to the same selection criteria. The technique of VCD was performed at single vertebral level in the thoracolumbar region of AS patients according to classification of AS kyphotic deformity. Pre- and post-operative chin-brow vertical angle (CBVA), sagittal vertical axis (SVA) and sagittal Cobb angle in the thoracolumbar region were reviewed in the VCD and PSO groups. Intra- , post-operative and general complications were analysed in both group.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 116 - 116
1 Jan 2016
Chou W Chien A Wang J
Full Access

PEEK rods construct has been proposed to allow better load sharing among spinal components when compared to the more traditional Titanium rods constructs. However, such proposal has largely derived from single-load in-vitro testing and the biomechanical differences between the two constructs when subjected to fatigue loading remain unknown. Current study comparatively analyzed the in-vitro biomechanical performance of PEEK and Titanium rod constructs as spinal implants through a 5 hour fatigue loading test. The disc height and intradiscal pressure of the instrumented and adjacent levels pre- and post-loading were recorded for analysis. The stress levels on the rods and bone stress near the screw-bone interface were also collected to investigate the likely failure rates of the two constructs. The results showed that the Titanium rods construct demonstrated a minimum amount of loss of disc height and intradiscal pressure at the instrumented level, however, a significant loss of the disc height and intradiscal pressure at adjacent levels compared to the intact spine were identified. In contrast, the disc height and intradiscal pressure of the PEEK rods were found to be comparable to those of the intact spine for all levels. The PEEK rods group also showed significantly less bone stress near the screw-bone interface compared to the Titanium rods group. Current study has demonstrated the potential benefits of the PEEK rods construct in reducing the risks of adjacent segment disease and implant failure rates when compared to the more traditional Titanium rods construct.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 905 - 910
1 Jul 2015
Hsu C Lin P Kuo F Wang J

Tranexamic acid (TXA), an inhibitor of fibrinolysis, reduces blood loss after total knee arthroplasty. However, its effect on minimally invasive total hip arthroplasty (THA) is not clear. We performed a prospective, randomised double-blind study to evaluate the effect of two intravenous injections of TXA on blood loss in patients undergoing minimally invasive THA.

In total, 60 patients (35 women and 25 men with a mean age of 58.1 years; 17 to 84) who underwent unilateral minimally invasive uncemented THA were randomly divided into the study group (30 patients, 20 women and ten men with a mean age of 56.5 years; 17 to 79) that received two intravenous injections 1 g of TXA pre- and post-operatively (TXA group), and a placebo group (30 patients, 15 women and 15 men with a mean age of 59.5 years; 23 to 84). We compared the peri-operative blood loss of the two groups. Actual blood loss was calculated from the maximum reduction in the level of haemoglobin. All patients were followed clinically for the presence of venous thromboembolism.

The TXA group had a lower mean intra-operative blood loss of 441 ml (150 to 800) versus 615 ml (50 to 1580) in the placebo (p = 0.044), lower mean post-operative blood loss (285 ml (120 to 570) versus 392 ml (126 to 660) (p = 0.002), lower mean total blood loss (1070 ml (688 to 1478) versus 1337 ml (495 to 2238) (p = 0.004) and lower requirement for transfusion (p = 0.021). No patients in either group had symptoms of venous thromboembolism or wound complications.

This prospective, randomised controlled study showed that a regimen of two intravenous injections of 1 g TXA is effective for blood conservation after minimally invasive THA.

Cite this article: Bone Joint J 2015;97-B:905–10.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 43 - 43
1 Jul 2014
Li R Patel H Perriman D Wang J Smith P
Full Access

Summary Statement

Using the latest Next Generation Sequencing technologies, we have investigated miRNA expression profiles in human trabecular bone from total hip replacement (THR) revision surgery where wear particle associated osteolysis was evident.

Introduction

A major problem in orthopaedic surgery is aseptic loosening of prosthetic implants caused by wear particle associated osteolysis. Wear debris is known to impact on a variety of cellular responses and genes in multiple pathways associated with the development of the periprosthetic osteolysis. MicroRNAs (miRNAs) act as negative regulators of gene expression and the importance of miRNAs in joint pathologies has only recently been addressed. However, miRNA profiles in osteolytic bone are largely unknown. Using the latest Next Generation Sequencing technologies, we have investigated miRNA expression profiles in human trabecular bone sourced from bone discarded during total hip replacement (THR) revision surgery where wear particle associated osteolysis was evident.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 72 - 72
1 Aug 2013
Lin H Wang J
Full Access

Objectives

Femoral shaft fracture treatment often results in mal-alignment and the high dosage of radiation exposure. The objective of this study is to develop a Parallel Manipulator Robot (PMR) on traction table to overcome these difficulties so as achieve better alignment for the fractured femur and reduce radiation to both patients and physicians.

Methods

The distal platform of PMR is attached to the central pole on standard traction table by the boot adaptor. A leg model with soft tissue made by Pacific Research Laboratory, Inc. is flexed at the knee with patella on the top. A 2/3 circular ring, with 1/3 open circle down, fixed to the fractured distal femur with one trans-wire and one self-tapping screw, acting as adaptable stirrup fixing scheme. To secure proximal femur, an adapter is assembled on the traction table and fixed on the proximal femur. The distal femur is fixed to the 2/3 circular ring platform of PMR. Surgical planning is performed by first acquiring the bi-planar images from the C-Arm X-ray machine. After simulated fracture on 3-D femoral model is made, proximal and distal segments of the model will be superimposed with background bi-planar images. Finally the pre-fractured length and mechanical axis of 3-D femoral model will be restored. Afterwards, a table of schedule for length adjustments of six struts of PMR is generated. This length adjustment schedule is used to drive the PMR for fractured femur alignment and reduction. When reduction completed, a special designed device is used to fix the reduced femur. Then the PMR is removed from the traction table and the patient can be removed from the traction table.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 57 - 57
1 Aug 2013
Wang J Hu L Zhao C Su Y Wang T Wang M
Full Access

Objectives

Percutaneous iliosacral screw placement is a standard, stabilization technique for pelvic fractures. The purpose of this study was to assess the effectiveness of a novel biplanar robot navigation aiming system for percutaneous iliosacral screw placement in a human cadaver model.

Methods

A novel biplanar robot navigation aiming system was used in 16 intact human cadaveric pelvises for percutaneous iliosacral screw insertion. The number of successful screw placements and mean time for this insertion and intra-operative fluoroscopy per screw-pair were recorded respectively to evaluate the procedure. The accuracy of the aiming process was evaluated by computed tomography.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 111 - 111
1 Aug 2013
Lin H Wang J
Full Access

Objective

Femoral shaft fracture treatment often results in mal-alignment and the high dosage of radiation exposure. The objective of this study is to develop a Parallel Manipulator Robot (PMR) on traction table to overcome these difficulties so as achieve better alignment for the fractured femur and reduce radiation to both patients and physicians.

Method

The distal platform of PMR is attached to the central pole on standard traction table by the boot adaptor. A leg model with soft tissue made by Pacific Research Laboratory, Inc. is flexed at the knee with patella on the top. A 2/3 circular ring, with 1/3 open circle down, fixed to the fractured distal femur with one trans-wire and one self-tapping screw, acting as adaptable stirrup fixing scheme. To secure proximal femur, an adapter is assembled on the traction table and fixed on the proximal femur. The distal femur is fixed to the 2/3 circular ring platform of PMR. Surgical planning is performed by first acquiring the bi-planar images from the C-Arm X-ray machine. After simulated fracture on 3-D femoral model is made, proximal and distal segments of the model will be superimposed with background bi-planar images. Finally the pre-fractured length and mechanical axis of 3-D femoral model will be restored. Afterwards, a table of schedule for length adjustments of six struts of PMR is generated. This length adjustment schedule is used to drive the PMR for fractured femur alignment and reduction. When reduction completed, a special designed device is used to fix the reduced femur. Then the PMR is removed from the traction table and the patient can be removed from the traction table.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 643 - 648
1 May 2013
Wang J Hsu C Huang C Lin P Chen W

Structural allografts may be used to manage uncontained bone defects in revision total knee replacement (TKR). However, the availability of cadaver grafts is limited in some areas of Asia. The aim of this study was to evaluate the mid-term outcome of the use of femoral head allografts for the reconstruction of uncontained defects in revision TKR, focusing on complications related to the graft.

We retrospectively reviewed 28 patients (30 TKRs) with Anderson Orthopaedic Research Institute (AORI) type 3 bone defects, who underwent revision using femoral head allografts and stemmed components. The mean number of femoral heads used was 1.7 (1 to 3). The allograft–host junctions were packed with cancellous autograft.

At a mean follow-up of 76 months (38 to 136) the mean American Knee Society knee score improved from 37.2 (17 to 60) pre-operatively to 90 (83 to 100) (p < 0.001). The mean function score improved from 26.5 (0 to 50) pre-operatively to 81 (60 to 100) (p < 0.001). All the grafts healed to the host bone. The mean time to healing of the graft was 6.6 months (4 to 16). There have been no complications of collapse of the graft, nonunion, infection or implant loosening. No revision surgery was required.

The use of femoral head allografts in conjunction with a stemmed component and autogenous bone graft in revision TKR in patients with uncontained bone defects resulted in a high rate of healing of the graft with minimal complications and a satisfactory outcome. Longer follow-up is needed to observe the evolution of the graft.

Cite this article: Bone Joint J 2013;95-B:643–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 932 - 936
1 Jul 2012
Lin P Hsu C Huang C Chen W Wang J

Tranexamic acid (TEA), an inhibitor of fibrinolysis, reduces blood loss after routine total knee replacement (TKR). However, controversy persists regarding the dosage and timing of administration of this drug during surgery. We performed a prospective randomised controlled study to examine the optimum blood-saving effect of TEA in minimally invasive TKR.

We randomly assigned 151 patients who underwent unilateral minimally invasive TKR to three groups: 1) a placebo group (50 patients); 2) a one-dose TEA group (52 patients), who received one injection of TEA (10 mg/kg) intra-operatively on deflation of the tourniquet; and 3) a two-dose TEA group (49 patients), who received two injections of TEA (10 mg/kg) given pre-operatively and intra-operatively. Total blood loss was calculated from the maximum loss of haemoglobin. All patients were followed clinically for the presence of venous thromboembolism (VTE).

The mean total blood loss was significantly higher in the placebo group than in the other two groups (1222 ml (845 to 2043) versus 1035 ml (397 to 1934) and 986 ml (542 to 1811), respectively (both p < 0.0001)). The mean blood loss was not significantly different between the one- and two-TEA groups (p = 0.148). The mean transfusion rate was higher in the placebo group than in the other two groups (22% versus 3.8% (p = 0.006) and 6.1% (p = 0.041), respectively) and there was no statistically significant difference in the mean transfusion rate between the one- and two-TEA groups (p = 0.672). Only one patient, in the two-dose group, had a radiologically confirmed deep venous thrombosis.

Our prospective randomised controlled study showed that one intra-operative injection of TEA is effective for blood conservation after minimally invasive TKR.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1392 - 1396
1 Oct 2010
Wang J Chen W Lin P Hsu C Wang C

Intra-articular resection of bone with soft-tissue balancing and total knee replacement (TKR) has been described for the treatment of patients with severe osteoarthritis of the knee associated with an ipsilateral malunited femoral fracture. However, the extent to which deformity in the sagittal plane can be corrected has not been addressed. We treated 12 patients with severe arthritis of the knee and an extra-articular malunion of the femur by TKR with intra-articular resection of bone and soft-tissue balancing. The femora had a mean varus deformity of 16° (8° to 23°) in the coronal plane. There were seven recurvatum deformities with a mean angulation of 11° (6° to 15°) and five antecurvatum deformities with a mean angulation of 12° (6° to 15°).

The mean follow-up was 93 months (30 to 155). The median Knee Society knee and function scores improved from 18.7 (0 to 49) and 24.5 (10 to 50) points pre-operatively to 93 (83 to 100) and 90 (70 to 100) points at the time of the last follow-up, respectively. The mean mechanical axis of the knee improved from 22.6° of varus (15° to 27° pre-operatively to 1.5° of varus (3° of varus to 2° of valgus) at the last follow-up. The recurvatum deformities improved from a mean of 11° (6° to 15°) pre-operatively to 3° (0° to 6°) at the last follow-up. The antecurvatum deformities in the sagittal plane improved from a mean of 12° (6° to 16°) pre-operatively to 4.4° (0° to 8°) at the last follow-up.

Apart from varus deformities, TKR with intra-articular bone resection effectively corrected the extra-articular deformity of the femur in the presence of antecurvatum of up to 16° and recurvatum of up to 15°.