header advert
Results 51 - 100 of 176
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 14 - 14
1 Mar 2013
Hart A Matthies A Racasan R Bills P Panagiotidou A Blunt L Blunn G Skinner J
Full Access

It has been speculated that high wear at the head-stem taper may contribute to the high failure rates reported for stemmed large head metal-on-metal (LH-MOM) hips. In this study of 53 retrieved LH-MOM hip replacements, we sought to determine the relative contributions of the bearing and taper surfaces to the total wear volume. Prior to revision, we recorded the relevant clinical variables, including whole blood cobalt and chromium levels. Volumetric wear of the bearing surfaces was measured using a coordinate measuring machine and of the taper surfaces using a roundness measuring machine. The mean taper wear volume was lower than the combined bearing surface wear volume (p = 0.015). On average the taper contributed 32.9% of the total wear volume, and in only 28% cases was the taper wear volume greater than the bearing surface wear volume. Despite contributing less to the total material loss than the bearing surfaces, the head-stem taper junction remains an important source of implant-derived wear debris. Furthermore, material loss at the taper is likely to involve corrosion and it is possible that the material released may be more biologically active than that from the bearing surface.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_12 | Pages 2 - 2
1 Mar 2013
Hexter A Panagiotidou A Singh J Skinner J Hart A
Full Access

The articulating surface replacement (ASR) XL stemmed total hip replacement and ASR resurfacing hip systems were recalled by DePuy due to a high prevalence of early failure. The ASR XL has a greater failure rate than the ASR resurfacing, which has been increasingly attributed to wear and corrosion at the taper interface between the female taper surface of the femoral head and the male taper (trunnion) of the femoral stem. The aim of this study was to quantify the prevalence and severity of taper corrosion in retrieved ASR XL hip components.

A peer-reviewed subjective corrosion scoring system was used to quantify corrosion in a consecutive series of the 50 ASR XL hip components (head components – n=44; femoral stems – n=6) at our retrieval centre. Bearing surface wear (femoral head and acetabular cup combined) was quantified and a value of <5 microns was defined as low-wearing. Subsequent profilometry analysis was undertaken in the low-wearing hips to quantify material loss from the taper interface.

90% of components showed evidence of corrosion, with at least moderate corrosion observed in 58%. There were 17 low-wearing hips which had a median material loss from the taper interface of 3.51mm3 (range: 0.612–9.443). The median linear depth of material loss was 33μm (range: 8.5–78.0). No relationship was observed between taper corrosion and serum cobalt (r=0.204, p=0.2712) or chromium (r=0.146, p=0.432) metal ions.

Wear and material loss from metal-on-metal (MoM) hips is associated with pseudotumour formation and adverse soft-tissue reactions. We have shown that taper corrosion is extremely common in failed ASR XL hips and that wear occurs in the same degree of magnitude as at the bearing surface also occurs at the taper interface. Therefore our findings support the emerging concept of ‘taper failure’, whereby the taper is the predominate reason for failure of MoM hips. Future work must determine the relative contributions of the bearing surface and the taper interface to serum cobalt and chromium metal ion levels.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_12 | Pages 3 - 3
1 Mar 2013
Hexter A Panagiotidou A Singh J Skinner J Hart A
Full Access

Corrosion at the taper interface between the femoral head and the femoral stem is well described in metal-on-polyethylene (MoP) hips but previously was undetermined in large diameter head metal-on-metal (LHMoM) hips. The high failure rate of the articulating surface replacement (ASR) XL hip system has been partly attributed to susceptibility to corrosive damage at the taper interface. It was not known if other hip manufacturers are liable to taper corrosion. Therefore the aim of this study was to quantify the prevalence and severity of taper corrosion in LHMoM hips and compare corrosion across five different current generation manufacturers.

Taper corrosion was analysed in a consecutive series of the five most common hip types at our retrieval centre: ASR XL, DePuy (n=49); Birmingham hip resurfacing, Smith & Nephew (n=33), Durom, Zimmer (n=31), M2a Magnum, Biomet (n=14) and Cormet, Stryker (n=10). A four-scale peer-reviewed qualitative corrosion scoring system was used to quantify corrosion (none, mild, moderate and severe).

Evidence of corrosion was observed in 86% of components, with at least moderate corrosion observed in 61%. No difference in corrosion was observed between the ASR XL and the other manufacturers (p=0.202). There was still no difference seen when all manufacturers were compared individually (p=0.363). A positive correlation was observed between corrosion and femoral head diameter (r=0.224, p=0.021). However no relationship was observed with implantation time (r=0.163, p=0.118).

Our study indicates that taper corrosion is common in LHMoM hips and affects all hip types equally. The clinical significance of this finding is that all hip types will be susceptible to the complications of corrosion, such as third body wear and osteolysis. Furthermore recent reports indicate that corrosive debris released from the taper interface may play a role in the formation of pseudotumours and adverse soft-tissue reactions. We found that larger femoral head sizes showed greater corrosion, which suggests that high torque increases fretting corrosion of the taper interface. Future work must determine the optimum femoral head size and investigate the chemical composition of the corrosive debris.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_12 | Pages 4 - 4
1 Mar 2013
Hexter A Panagiotidou A Singh J Skinner J Hart A
Full Access

In metal-on-metal (MoM) total hip arthroplasty, the taper interface is where the femoral head (female taper surface) attaches to the trunnion (male taper) of the femoral stem. Corrosion is well reported in metal-on-polyethylene hips but little is known about taper corrosion in MoM devices. The aim of this study was to quantify corrosion in modern-generation stemmed MoM hip systems and gain insight into the nature of the underlying corrosive attack.

Taper corrosion was quantified in 161 failed MoM components (head components n=128; femoral stem n=33) from nine hip types with the use of a qualitative subjective scoring system. An unanticipated finding on preliminary inspection of the hips was a region on the female taper surface that contained ridges that directly corresponded with the ridged microthread on the trunnion. The ridges were not present on unimplanted (control) female taper surfaces and therefore a novel four-scale subjective scoring system was devised to quantify the prevalence and severity of this ‘imprinting’ phenomenon.

Evidence of corrosion was observed in 81% (131/161) of components, with at least moderate corrosion observed in 58% (94/161). Corrosion was greater on the female taper surface than on the male taper (p=0.034) and the two scores were associated (r=0.784, p=0.001). Imprinting affected all manufacturers and was observed in 64% (82/128) of head components. The corrosion and imprinting scores were strongly correlated (r=0.694, p=0.001). Corrosion was largely confined to the area of the female taper interface where imprinting had occurred i.e. the region that had been in contact with the trunnion microthread. Scanning electron microscopy showed evidence of fretting corrosion and substantial mechanical wear within the ridged region on the female taper surface.

Our study indicates that MoM hips are susceptible to taper corrosion. We believe it occurs by a process of “mechanically-assisted crevice corrosion,” involving the following sequence of events: joint fluid enters the taper junction as a result of pumping of fluid along the machined microthread of the trunnion. This results in galvanic corrosion of the anodic surface (the cobalt-chromium femoral head or taper sleeve). The pattern of corrosion of the head taper is determined by the surface profile of the screw thread of the trunnion, thus leaving an imprinted appearance. Historically the ridged microthread was introduced to trunnions to minimise the risk of burst fracture of ceramic heads. However this study indicates that the ridges are detrimental in MoM hips by causing extensive mechanical wear. Thus the possibility that cobalt-chrome and ceramic femoral head components require different trunnion designs needs urgent investigation.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 21 - 21
1 Mar 2013
RAHMAN J KAYANI B GILLOTT E BENTLEY G SKINNER J MILES J CARRINGTON R BRIGGS T
Full Access

The Royal National Orthopaedic Hospital has completed an extensive trial of ACI versus MACI in the treatment of symptomatic osteochondral defects of the knee. A new technique has now been proposed which is quicker and easier to perform. This is the Gel-Type Autologous Chondrocyte Transplantation, CHONDRONTM. At Stanmore CHONDRON has been used for the past 17 months. Our aim was to assess the short term functional outcome of patients who have undergone CHONDRONTM using validated outcome scoring questionnaires. We retrospectively reviewed the notes of 43 patients that had undergone CHONDRONTM over one year ago and scored them using the Modified Cincinnati Score, the Visual Analogue Score and the Benltey Stanmore Functional Rating Score.

RESULTS

The mean pre-operative Modified Cincinnati Score was 39.9, which improved to a mean of 59.8 post-operatively. The mean Visual Analogue Score improved from 6.7 to 5.1 post-operatively. The median Bentley Functional Rating Score was 3 pre-operatively and 2 post-operatively.

CONCLUSIONS

These early results show that 76% of the patients who were treated with CHONDRONTM experienced a reduction in pain and improvement in post-operative function. In the patients in whom the symptoms were worse, the deterioration in score could be partly explained by numerous previous procedures on the same site, presence of early osteoarthritis or the presence of multiple osteochondral lesions. This highlights the importance of careful patient selection in order to gain maximum benefit from the procedure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_7 | Pages 7 - 7
1 Feb 2013
Sewell M Carrington R Pollock R Skinner J Cannon S Briggs T
Full Access

Patients with skeletal dysplasia are prone to developing advanced degenerative knee disease requiring total knee replacement (TKR) at a younger age than the general population. TKR in this unique group of patients is a technically demanding procedure due to the bone deformity, flexion contracture, generalised hypotonia and ligamentous laxity. We set out to retrospectively review the outcome of 11 TKR's performed in eight patients with skeletal dysplasia at our institution using the SMILES custom-made rotating-hinge total knee system. There were 3 males and 5 females with mean age 57 years (range, 41–79 years), mean height 138 cm (range, 122–155 cm) and mean weight 56 kg (range, 40–102 kg). Preoperative diagnoses included achondroplasia, spondyloepiphyseal dysplasia, pseudoachondroplasia, multiple epiphyseal dysplasia, morquio syndrome, diastrophic dysplasia and Larson's Syndrome. Patients were followed clinically and radiographically for a mean of 7 years (range, 3–11.5 years). Knee pain and function improved in all 11 joints. Mean Knee Society clinical and function scores improved from 24 (range, 14–36) and 20 points (range, 5–40) preoperatively to 68 (range, 28–80) and 50 points (range, 22–74) respectively at final follow-up. Four complications were recorded (36%), including a patellar fracture following a fall, a tibial periprosthetic fracture, persistent anterior knee pain and a femoral component revision for aseptic loosening. Our results suggest that custom rotating-hinge TKR in patients with skeletal dysplasia is effective at relieving pain, optimising movement and improving function. It compensates for bony deformity and ligament deficiency and reduces the need for corrective osteotomy. Patellofemoral joint complications are frequent and functional outcome is worse than primary TKR in the general population.

Submission endorsed by Mr Peter Calder, Consultant Orthopaedic Surgeon and Society member


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 142 - 142
1 Jan 2013
Matthies A Suarez A Karbach L Isamailly S Henckel J Skinner J Noble P Hart A
Full Access

Introduction

Edge loading is a common wear mechanism in Metal-on-Metal (MOM) hip resurfacing and is associated with higher wear rates and the incidence of pseudotumour. The purpose of this study was to develop a method to investigate the contributions of patient, surgical and implant design variables on the risk of edge loading.

Method

We created a mathematical model to calculate the distance from the head-cup contact patch to the rim of the cup and used this to investigate the effect of component position, specific design features and patient activity on the risk of edge loading. We then used this method to calculate the contact patch to rim distance (CPRD) for 160 patients having undergone revision of their MOM hip resurfacing in order to identify any possible associations.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 31 - 31
1 Jan 2013
Dhinsa B Gallagher K Dawson-Bowling S Mohan A Miles J Carrington R Skinner J Briggs T
Full Access

Introduction

The aim of this study was to see if the evaluation of the initial postoperative radiograph following primary knee and hip arthroplasty correlated with clinical outcome at five years postoperatively.

Methodology

Using our institution database we identified forty-nine hip replacements and fifty-two knee replacements performed between 2000 and 2006. All the patients underwent postoperative radiographs one day after surgery and clinical evaluation up to at least five years postoperatively. A consultant radiologist evaluated the radiographs for alignment and component position. The hip arthroplasty patients were assessed clinically using the Harris hip score, Oxford hip score, and the Western Ontario and McMaster Universities Osteoarthritis index (WOMAC). The knee arthroplasty patients were assessed using the Knee Society score, Oxford knee score, and the WOMAC score.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 73 - 73
1 Jan 2013
Gillott E Sun SNM Carrington R Skinner J Briggs T Miles J
Full Access

Background

The Enhanced Recovery Programme (ERP) is an evidence based initiative aimed at speeding up patient recovery after major surgery and improving their outcomes. The Royal National Orthopaedic Hospital, Stanmore (RNOH) is a specialist orthopaedic and implemented an ERP for primary knee arthroplasties from October 2010.

Aims

To analyse the initial results of patients participating in our ERP for primary knee arthroplasty to identify what factors predict their Length of Stay (LoS) and establish where changes can be made to improve outcomes further.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 140 - 140
1 Jan 2013
Matthies A Chan N Jones H Isamailly S Skinner J Noble P Hart A
Full Access

Introduction

It has been speculated that impact deformation of thin 1-piece cups used for modern metal-on-metal hip replacement may contribute to early failure. The purpose of this study was to reproduce typical impact deformation and quantify the effect of this on the frictional torque generated at the hip.

Methods

We tested nine hip couples of three designs (the ASR, BHR and Durom) and three sizes (42mm, 46mm and 50mm). A custom compression device was designed to replicate the in vivo forces and impact deformation of 1-piece metal cups reported in the literature. Each cup was mounted in the device, which itself was mounted on a mechanical testing machine. The cups were compressed with incremental loads up to a maximum of 2000N. At each increment we measured cup deformation, and then the head component was seated into the cup. The hip was lubricated and the head component rotated 60 degrees axially within the cup and the axial torque was measured.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 115 - 115
1 Sep 2012
Gillott E Kahane S Aston W Briggs T Skinner J Pollock R
Full Access

Aims

Present the outcomes of those patients diagnosed with Ewing's Sarcoma of the foot within the past 10 years and treated at the Royal National Orthopaedic Hospital's Bone Tumour Unit, Stanmore.

Methods

Retrospective study of the cases identified from the pathology database. Notes reviewed for presentation, treatment and follow up. TESS (Toronto Extremity Salvage Score) and MSTS (Musculoskeletal tumour score) were calculated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 85 - 85
1 Sep 2012
Stammers J Kahane S Malek S Aston W Miles J Pollock R Carrington R Briggs T Skinner J
Full Access

Infection after knee arthroplasty is a devastating complication. Our aim is to present our outcomes of treating infected knee replacements at a tertiary referral centre.

We performed a consecutive, retrospective case series of all revision knee arthroplasty for infection between January 2006 and December 2008. Case notes were reviewed and data collated on the date and institution of primary arthroplasty, procedures undertaken at our institution, microbiology and bone loss post first stage, serological markers (C-reactive protein, ESR) prior to second stage and outcome.

During this three year period we performed 430 knee revision operations. 51 were in the presence of deep chronic infection. 90% were referred from other hospitals. Overall infection was successfully eradicated in 69%.

Nineteen patients underwent repeat two-stage and overall eleven (58%) patients had successful eradication of infection with multiple two-stages. Of these 47% had F3/T3, the highest grading of Anderson Orthopaedic Research Institute bone loss indicating no metaphyseal bone. A further 12% had bicondylar deficiency on the tibia and no femoral metaphyseal bone (F3/T2b).

Multidrug resistance present in 69% and 47% were infected with multiple organisms. All members of the unsuccessful outcome group had at least one multidrug resistant organism compared to 43% in the successful cohort (P=0.0002). Multiple organisms are associated with an unsuccessful outcome (P=0.056).

Serological markers were not significantly different between the successful and unsuccessful outcome groups.

Where the referring hospital had attempted revision and failed, the chance of eradicating infection dropped from 75% to 58% and the rate of above knee amputation was twelve times higher (3% vs. 36%).

Custom constrained, rotating hinge prostheses enable aggressive soft tissue debridement including ligaments. Successful two-stage requires a multidisciplinary approach including tissue viability nurses, microbiologists and plastic surgeons. Where units lack revision expertise this series suggests early referral increases the chance of limb salvage.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 22 - 22
1 Sep 2012
Sandiford N Muirhead-Allwood S Skinner J Hua J Peter W
Full Access

Introduction

Optimal results from uncemented total hip arthroplasty (THA) requires the prosthesis to obtain initial stability, restoration of biomechanics, bone contact along the ingrowth surface and uniform stress transfer to the proximal femur. Anatomic variation within the population makes this difficult to reproduce in every patient. To achieve optimal fit and fill of the proximal femur, options are reshaping the canal or creating an implant which precisely fits the patient's anatomy. The former increases bone loss and risks weakening the supporting bone, creating areas of stress concentration or shielding. Computer assisted design-computer assisted manufacture (CAD-CAM) femoral components were designed to overcome these issues. We present the long term results of CAD-CAM femoral components used in primary THA.

Methods

This was a prospective study looking at a consecutive, single surgeon series of THA's. Patients were reviewed pre operatively then at 6 weeks, 3 and 12 months post operatively and then yearly. Clinical as well as radiological review was performed at each visit and Harris Hip Score (HHS), Oxford Hip Score (OHS) and Western Ontario McMaster's (WOMAC) scores were calculated. Kaplan-Meier survival analysis was performed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 110 - 110
1 Sep 2012
Perera J Griffiths D Gikas P Perera J Donaldson J Aston W Pollock R Skinner J Cannon S Briggs T
Full Access

Sixty eight consecutive patients underwent proximal humeral replacement with a fixed fulcrum massive endoprosthesis, for tumour, between 1997 and 2007. The mean age was 46 years, (7–87). Ten patients were lost to follow up and 16 patients died. The 42 surviving patients were assessed using the Musculoskeletal Tumour Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS). The mean MSTS score was 72.3% and the mean TESS was 77.2%.

Four of 42 patients received a new constrained humeral liner to reduce the risk of dislocation. This sub group of 4 patients had a mean MSTS score of 77.7% and a mean TESS of 80.0%.

Endoprosthetic replacement for tumour of the proximal humerus using this prosthesis is a reliable operation yielding good functional results without the documented problems of unconstrained prostheses. The performance of this prosthesis is expected to improve further with the new constrained humeral liner.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 321 - 321
1 Sep 2012
Jalgaonkar A Mohan A Pollock R Skinner J Cannon S Briggs T Aston W
Full Access

Percutaneous biopsies can lead to seeding of tumour cells along the biopsy tract.

Correct surgical management requires preoperative identification and excision of the biopsy tract at time of surgery. These tracts become increasingly difficult to identify with time, leading to risk of inadequate excision of the biopsy tract and recurrence of the tumour at the biopsy site. We conducted a prospective study involving 45 patients who had tissue biopsies for bone and soft tissue tumours between February and May 2008. All the biopsies were performed by consultant radiologist under ultrasound or CT guidance. Case note analysis, patient history and examination at the time of surgery were used to collect data. 23 of 45 patients had accurate identification of the biopsy tract by the surgeon at the time of excision. The mean time between biopsy and excision was 52 days (range 6–140). 22 of 45 patients had unidentifiable biopsy site, with the mean time between biopsy and excision being 98 days(range 13–164) p=0.0004(paired t test). All 4 patients who received post-biopsy radiotherapy had unidentifiable biopsy site tract (mean duration 104 days) and 11 of the 18 patients who underwent neoadjuvant chemotherapy had an unidentifiable biopsy tract (mean duration 108 days). We concluded that identification of biopsy site was more difficult after 50 days, especially in patients who underwent radiotherapy and chemotherapy.

Following this study, all the patients who had biopsies of tumours had the site marked with India ink tattoo. We, then prospectively reviewed 36 patients between July and September 2010 who underwent excision of bone and soft tissue tumours and had their biopsy sites marked with India ink tattoo. After needle biopsy, one drop of the dye was applied at the site of the biopsy. This was taken up by capillary action beneath the dermis and remained present until the patient returned for their definitive surgery. The biopsy site was easily identifiable by the patients and the operating surgeon in all 36 patients. The mean time between biopsy and surgery was 77 days (range 10–299 days). Tattooing of the skin enabled the surgeon to accurately excise the biopsy tract along with the tumour. We recommend this technique of tattooing of the biopsy site with India ink, as it is safe, easily recognisable and permits accurate excision of the tract (including the tattoo), therefore preventing biopsy tract recurrence.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 90 - 90
1 Sep 2012
Nawaz S Gallagher K Dhinsa B Carrington R Skinner J Briggs T Bentley G
Full Access

Chondral injuries of the knee are extremely common and present a unique therapeutic challenge due to the poor intrinsic healing of articular cartilage. These injuries can lead to significant functional impairment. There are several treatment modalities for articular osteochondral defects, one of which is autologous chondrocyte implantation. Our study evaluates the mid to long term functional outcomes in a cohort of 828 patients who have undergone an autologous chondrocyte implantation procedure (either ACI or MACI), identifying retrospectively factors that may influence their outcome.

The influence of factors including age, sex, presence of osteoarthritis and size and site of lesion have been assessed individually and with multivariate analysis. All patients were assessed using the Bentley Functional Score, Visual Analogue Score and the Cincinnati Functional Score. Assessment were performed pre-operatively and of their status in 2010.

The longest follow-up was 12 years (range 24 to 153 months) with a mean age of 34 years at time of procedure. The mean defect size was 409 mm2 (range 64 to 2075 mm2). The distribution of lesions was 51% Medial Femoral Condyle, 12.5% Lateral Femoral Condyle, 18% Patella (single facet), 5% Patella (Multifacet) and 6% Trochlea. 4% had cartilage transplant to multiple sites.

High failure rates were noted in those with previous cartilage regenerative procedures or evidence of early osteoarthritis and those with transplantation to multiple sites.

Autologous chondrocyte implantation is an effective method of decreasing pain and increasing function, however patient selection plays clear role in the success of such procedure.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 116 - 116
1 Sep 2012
Dawson-Bowling S Berber O Jalgaonkar A Miles J Aston W Pollock R Skinner J Briggs T
Full Access

Bizarre parosteal osteochondromatous proliferation (BPOP), or Nora's lesion, is a rare condition characterised by the formation of surface-based osteocartilaginous lesions typically affecting the hands and feet. 22 cases were identified from the records of a regional bone tumour unit, dating from 1985 to 2009. Of 22 cases, 9 lesions involved the long bones of the hand, 7 the long bones of the feet, 1 case originated from a sesamoid bone of the foot and 5 from long bones (radius, ulna, femur [2] and tibia). Age ranged from 6 to 66 (mean: 31.8) and male to female ratio was 1.8:1. Diagnosis was based on combined radiological and histological features, and initial surgical treatment was excision in 21 cases, and 1 amputation. Follow-up ranged from 12–162 months (mean 32). Recurrence occurred in 6 patients (27%), with mean time to recurrence 49 months (range 10–120). 2 of 8 patients with complete resection margins developed recurrence (25%), versus 4 of 14 with marginal or incomplete resection (28%). Given the potential surgical morbidity inherent in resection, our data suggest that there may be a role for a relatively tissue-conserving approach to the excision of these lesions.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 26 - 26
1 Sep 2012
Sandiford N Muirhead-Allwood S Skinner J Hua J Peter W
Full Access

Introduction

The variability of the endosteal geometry after removal of the femoral component can make proximal fit difficult to achieve with an ‘off the shelf’ prosthesis. Whatever the anatomy of the proximal femur, it is important to achieve immediate stability, preserve bone stock and protect the femur from cortical defects which can lead to subsequent fracture. In revision Total Hip Arthroplasty (THA) this requires a large inventory of modular components. The use of custom computer-assisted design-computer-assisted manufacture (CAD-CAM) components negates this need. Little has been published on the use of custom-made components in revision THA. We report the results of a cohort of patients who underwent revision THA using CAD-CAM femoral components.

Methods

A prospective study was performed between 1991 and 1998. A consecutive series of patients who had revision THA using custom components were assessed clinically and radiologically. The design of the femoral components was governed by the existing femoral bone stock. Patients were reviewed pre operatively then at 6 weeks, 3months and 12 months postoperatively and then annually. Radiographs were assessed at each visit and Oxford, Harris and WOMAC hip scores were calculated


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 28 - 28
1 Sep 2012
Sandiford N Muirhead-Allwood S Skinner J
Full Access

Introduction

Metal on metal hip resurfacing arthroplasty (MoM HR) has the highest revision rates according to the UK National Joint Registry. Revisions for lesions associated with soft tissue necrosis (pseudotumors) have been associated with poor outcomes. There is a relative paucity of information on early revision of painful HR prostheses. We present the results of a series of patients who underwent early revision of painful MoM HR procedures.

Methods

This prospective study involved a consecutive series of patients undergoing revision of HR to THA. The diagnoses leading to revision are discussed. Clinical and radiological assessments were performed pre operatively as well as 6 weeks, 12 months postoperatively and yearly thereafter. Pre and post operative Harris Hip Score, Oxford Hip Score and WOMAC scores were calculated. Patient satisfaction was assessed using a visual analogue scale.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 15 - 15
1 Sep 2012
Holleyman R Gikas P Tyler P Coward P Carrington R Skinner J Briggs T Miles J
Full Access

Background

It is known that excessive varus alignment of the femoral stem in total hip replacement (THR) creates a sub-optimal biomechanical environment which is associated with increased rates of revision surgery and component wear. Little is known regarding the effect of femoral stem alignment on patient functional outcome.

Methods

A retrospective study of patients undergoing primary THR at the RNOH. Alignment of the femoral stem component in-situ was measured subjectively by a consultant musculoskeletal radiologist in both coronal and sagittal planes using post-operative anterior-posterior and lateral pelvic radiographs. Each THR was grouped into valgus, minor-valgus, neutral, minor-varus or varus coronal plane alignment and posterior, minor-posterior, neutral, minor-anterior or anterior sagittal plane alignment. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires after a minimum follow-up of 11 months. Maximum range of passive hip flexion, abduction, adduction, external and internal rotation were measured in clinic. A factorial linear regression model was used to analyse data.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 232 - 232
1 Sep 2012
Sandiford N Muirhead-Allwood S Skinner J
Full Access

Introduction

There is no consensus on the ideal management of young, active patients with disabling coxarthrosis. Within this group, patients with femoral head defects secondary to cysts or avascular necrosis pose particular challenges. Resurfacing arthroplasty is contraindicated and the results of traditional total hip arthroplasty are suboptimal in this group. The BMHR was designed to offer a bone conserving option for these patients. We report the outcome of this device in the short term.

Methods

This prospective study examines the clinical and radiological outcome of a consecutive series of patients treated with the BMHR arthroplasty. All patients had femoral head defects and disabling hip pain. Patients were reviewed pre operatively and then at 6 weeks, 12 weeks, and 1year post operatively and then yearly. Oxford, Harris and WOMAC hip scores were calculated at each review. Radiological assessment was also performed at each follow up.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 571 - 571
1 Sep 2012
Nawaz S Bentley G Briggs T Carrington R Skinner J Gallager K Dhinsa B
Full Access

Chondral injuries of the knee are extremely common and present a unique therapeutic challenge due to the poor intrinsic healing of articular cartilage. These injuries can lead to significant functional impairment. There are several treatment modalities for articular osteochondral defects, one of which is autologous chondrocyte implantation. Our study evaluates the mid to long term functional outcomes in a cohort of 828 patients who have undergone an autologous chondrocyte implantation procedure (either ACI or MACI), identifying retrospectively factors that may influence their outcome.

The influence of factors including age, sex, presence of osteoarthritis and size and site of lesion have been assessed individually and with multivariate analysis. All patients were assessed using the Bentley Functional Score, Visual Analogue Score and the Cincinnati Functional Score. Assessment were performed pre-operatively and of their status in 2010. The majority of patients had several interim scores performed at varying intervals.

The longest follow-up was 12 years (range 24 to 153 months) with a mean age of 34 years at time of procedure. The mean defect size was 486 mm2 (range 64 to 2075 mm2). The distribution of lesions was 51% Medial Femoral Condyle, 12.5% Lateral Femoral Condyle, 18% Patella (single facet), 5% Patella (Multifacet) and 6% Trochlea. 4% had cartilage transplant to multiple sites. 30% failed following this procedure at a mean time of 72 months. 52% patients stated a marked improvement in their functional outcomes within the first two years. 49% stated an excellent result following their procedure.

High failure rate was noted in those with previous cartilage regenerative procedures, transplants occurring on the patella, particularly if involving multifacets. Multiple site cartilage transplantation was also associated with a high failure rate.

Autologous chondrocyte implantation is an effective method of decreasing pain and increasing function, however patient selection plays clear role in the success of such procedure.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 110 - 110
1 Sep 2012
Al-Hadithy N Gikas P Perera J Aston W Pollock R Skinner J Lotzof K Cannon S Briggs T
Full Access

The surgical treatment of bone tumours can result in large perioperative blood loss due to their large sizes and hypervascularity. Preoperative embolisation has been successfully used to downgrade vascularity, thus reducing perioperative blood loss and its associated complications. Prior to embolization era, blood loss as high as 18,500mL have been reported peri-opratively.

Twenty-six patients with a variety of bone tumours (average size 10.5×7.5×5.5cm), who underwent pre-operative embolisation between 2005 and 2009, were retrospectively studied. The group comprised of 17 females and 9 males. Their mean age was 38 years old. All patients underwent surgical resection within 48 hours of embolization. Mean blood loss was 796mL and required on average 1.1units of blood. We experienced no complications.

Pre-operative arterial embolisation of large, richly vascular bone tumours in anatomically difficult positions, is a safe and effective method of downstaging vascularity and reducing blood loss.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 231 - 231
1 Sep 2012
Matthews D Bhamra J Gupta A Ranawat V Miles J Skinner J Carrington R
Full Access

Aims

Revision total hip arthroplasty is a common operation. The MP Link (Waldemar Link, Hamburg, Germany) system is a distally loading, modular, tapered femoral stem component for revision hip surgery. MP Link in revision total hip arthoplasty was investigated clinically, radiologically and with Oxford hip scores.

Methods

A prospective study was conducted of 43 patients undergoing revision total hip arthroplasty with MP Link prostheses between 2004 and 2010. The patients were operated upon by one of the senior authors (JM, JS, RC). Outcome data was collected in clinic and via patient questionnaires.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 69 - 69
1 Aug 2012
Picardo N Nawaz Z Gallagher K Whittingham-Jones P Parratt T Briggs T Carrington R Skinner J Bentley G
Full Access

The aim of this study was to determine whether the clinical outcome of autologous chondrocyte transplantation was dependent on the timing of a high tibial osteotomy in tibio-femoral mal-aligned knees. Between 2000 and 2005, forty-eight patients underwent autologous chondrocyte implantation with HTO performed at varying times relative to the second stage autologous chondrocyte implantation procedure. 24 patients had HTO performed simultaneously with their second stage cartilage transplantation, (the HTO Simultaneous Group). 5 patients had HTO prior to their cartilage procedure, (the HTO pre-ACI Group) and 19 had HTO performed between 1 to 4 years after their second stage cartilage implantation, (the HTO post-ACI Group). There were 29 men and 19 women with a mean age of 37 years (Range 28 to 50) at the time of their second stage procedure.

With average follow-up of 72 months we have demonstrated a significant functional benefit in performing the HTO either prior to or simultaneously with the ACI procedure in the mal-aligned knee. The failure rate in the Post-ACI group was 45% compared to the Pre-ACI and Simultaneous group, with failure rates of 20% and 25%, respectively.

An HTO performed prior to or simultaneously with an autologous chondrocyte implantation procedure in the mal-aligned knee, provides a significant protective effect by reducing the failure rate by approximately 50%.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 120 - 120
1 Aug 2012
Holleyman R Gikas P Tyler P Coward P Carrington R Skinner J Briggs T Miles J
Full Access

Background

The position of the hip-joint centre of rotation (HJC) within the pelvis is known to influence functional outcome of total hip replacement (THR). Superior, lateral and posterior relocations of the HJC from anatomical position have been shown to be associated with greater joint reaction forces and a higher incidence of aseptic loosening. In biomechanical models, the maximum force, moment-generating capacity and the range of motion of the major hip muscle groups have been shown to be sensitive to HJC displacement. This clinical study investigated the effect of HJC displacement and acetabular cup inclination angle on functional performance in patients undergoing primary THR.

Methods

Retrospective study of primary THR patients at the RNOH. HJC displacement from anatomical position in horizontal and vertical planes was measured relative to radiological landmarks using post-operative, calibrated, anterior-posterior pelvic radiographs. Acetabular cup inclination angle was measured relative to the inter-teardrop line. Maximum range of passive hip flexion, abduction, adduction, external and internal rotation were measured in clinic. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires. Data analysed using a linear regression model.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 40 - 40
1 Aug 2012
Dhinsa B Nawaz S Gallagher K Carrington R Briggs T Skinner J Bentley G
Full Access

Introduction

Autologous chondrocyte implantation (ACI) is contra-indicated in a joint rendered unstable by a ruptured anterior cruciate ligament (ACL). We present our experience of ACI repair with ACL reconstruction

Methods

Patients underwent arthroscopic examination and cartilage harvesting of the knee. A second operation was undertaken approximately six weeks later to repair the ruptured ACL with hamstring graft or Bone patella-Bone (BPB) and to implant the chondrocytes via formal arthrotomy. Three groups were assessed: Group 1: Simultaneous ACL Reconstruction and ACI; Group 2: Previous ACL Reconstruction with subsequent ACI repair; Group 3: Previously proven partial or complete ACL rupture, deemed stable and not treated with reconstruction with ACI procedure subsequently. Patients then underwent a graduated rehabilitation program and were reviewed using three functional measurements: Bentley functional scale, the modified Cincinnati rating system, and pain measured on a visual analogue scale. All patients also underwent formal clinical examination at review.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 111 - 111
1 Aug 2012
Holleyman R Gikas P Tyler P Coward P Carrington R Skinner J Briggs T Miles J
Full Access

It is known that excessive varus alignment of the femoral stem in total hip replacement (THR) creates a sub-optimal biomechanical environment which is associated with increased rates of revision surgery and component wear. Little is known regarding the effect of femoral stem alignment on patient functional outcome.

Methods

Retrospective study of primary THR patients at the RNOH. Alignment of the femoral stem component in-situ was measured subjectively by a consultant musculoskeletal radiologist in both coronal and sagittal planes using post-operative anterior-posterior and lateral pelvic radiographs. Each THR was grouped into valgus, minor-valgus, neutral, minor-varus or varus coronal plane alignment and posterior, minor-posterior, neutral, minor-anterior or anterior sagittal plane alignment. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires. Data analysed using a linear regression model.

Results

90 THRs were studied in 87 patients (55 Female). Mean age at THR=62 (22-86). Mean follow-up=17 months (11-39 months). Median OHS=16, WOMAC=8. Coronal plane alignment of the femoral stem was not associated with any change in OHS (p>0.05) or WOMAC score (p>0.05). Sagittal plane alignment of the femoral stem was not associated with any change in OHS (p>0.05) or WOMAC score (p>0.05).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 12 - 12
1 Aug 2012
Shekkeris A Perera J Bentley G Flanagan A Miles J Carrington R Skinner J Briggs T
Full Access

Articular cartilage implantation (ACI) and associated procedures (MACI = Matrix-assisted cartilage implantation) are now established treatments for osteochondral defects in the knee. The quality of repair in terms of histological appearance is frequently not known, whilst the correlation of histology results with functional outcomes remains undefined. Histological data of the quality of the repair tissue is sparse and a precise classification proved difficult.

This was a single-centre, prospective study. Over 12 years (1998-2010) 406 patients that underwent articular cartilage implantation procedures at our institution (ACI = 170, MACI = 205) had biopsies taken at the 1-2 year interval, in order to assess whether these contained ‘hyaline-like’ cartilage, ‘mixed hyaline-like with fibrocartilage’, fibrocartilage or fibrous tissue alone.

Histological sections of the biopsies were prepared and stained with haematoxylin, eosin and proteoglycan stains and viewed under polarised light. All biopsies were studied by a single histopathologist in a specialist, dedicated musculoskeletal laboratory.

All patients were assessed by the Cincinnati, Bentley and Visual Analogue scores both pre-operatively and at the time of the review.

The findings revealed that 56 patients healed with ‘hyaline-like’ cartilage (14.9%), 103 with ‘mixed’ (27.5%), 179 with fibrocartilage (47.7%) and 37 with fibrous tissue (9.9%).

These findings showed that 42.4% of defects were filled with ‘hyaline-like’ or ‘mixed’ cartilage, with 70% of these achieving a ‘fair’ to ‘excellent’ functional outcome. This was also observed in the fibrocartilage group, where 72% achieved similar results. Predictably 89% of the patients that healed by fibrous tissue had a poor functional outcome.

This study shows that 71% of patients whose osteochondral defects healed by either ‘hyaline-like’, ‘mixed’ or fibrocartilage experienced an improvement in the function. In contrast, only 11% of the patients whose defects filled with fibrous tissue, showed some functional improvement. Additionally, this data indicates the advantage of biopsies in assessing the overall results of cartilage implantation procedures.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 17 - 17
1 Jul 2012
Picardo N Blunn G Shekkeris A Aston W Pollock R Meswania J Cannon S Skinner J Briggs T
Full Access

Introduction

Following bone tumour resection, lower limb reconstruction results in leg-length discrepancy in skeletally immature patients. Previously, minimally invasive endoprostheses have been associated with a high risk of complications including joint stiffness, nerve injury, aseptic loosening and infection. The purpose of this study was to examine the outcome of the Stanmore non-invasive extendible endoprostheses used in our institution between 2002 and 2009 and compare them with implants used in the past.

Methods

Fifty-five children with a mean age of 11.4 years (5 to 16) underwent limb reconstruction with thirty-three distal femoral, two total femoral, eight proximal femoral and twelve proximal tibial implants. Forty-six endoprostheses were lengthened in clinic without anaesthesia using the principle of electromagnetic induction. Patients were assessed using the Musculoskeletal Tumour Society Score (MSTS) and the Toronto Extremity Salvage Score (TESS).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 40 - 40
1 Jul 2012
Sabharwal S Datta G Berber O Aston W Pollock R Skinner J Cannon S Briggs T
Full Access

Introduction

The proximity of the superior tibiofibular articulation to neurovascular structures makes the management of extraosseous tumours of the proximal fibula challenging in bone tumour surgery. The aim of study is to establish whether the recurrence rates are higher in this anatomical area compared to data that already exists in publication for bone tumours throughout the appendicular skeleton.

Method

A retrospective study of all patients treated for Ewing's tumours and osteosarcoma at a regional bone tumour unit between January 1995 and December 2009 was conducted.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 6 - 6
1 Jul 2012
Shekkeris A Pollock R Aston W Cannon S Blunn G Skinner J Briggs T
Full Access

Introduction

Primary bone tumours of the distal radius are rare, while it remains the third commonest site for primary lesions and recurrences of Giant Cell Tumours (GCT). The functional demands on the hand make reconstruction of the wrist joint following the excision of distal radius, particularly challenging.

Methods

A single-centre retrospective study, reporting the functional and oncological outcomes of six patients (4 males, 2 females - mean age of 53 (22 to 79)) who underwent a custom-made endoprosthetic replacement of the distal radius with arthrodesis at our institution, during 1999 - 2010. Five patients were diagnosed with primary bone sarcoma of the distal radius (4 GCTs, 1 osteosarcoma) and another had a metastatic lesion from a primary renal cell carcinoma. The diagnosis was confirmed by needle biopsy in all cases.

We assessed the patients' functional outcomes using the Musculoskeletal Tumour Society scoring system (MSTS) and the Toronto Extremity Salvage Score (TESS).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 16 - 16
1 Jul 2012
Perera J Gikas P Griffiths D Donaldson J Aston W Pollock R Skinner J Cannon S Briggs T
Full Access

Sixty eight consecutive patients underwent proximal humeral replacement with a fixed fulcrum massive endoprosthesis for tumour between 1997 and 2007. The mean age was 46 years (7-87). Ten patients were lost to follow up and 16 patients died. The 42 surviving patients were assessed using the Musculoskeletal Tumour Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS). The mean MSTS score was 72.3 % and the mean TESS was 77.2 %.

Four of 42 patients received a new constrained humeral liner to reduce the risk of dislocation. This sub group of 4 patients had a mean MSTS score of 77.7 % and a mean TESS of 80.0%.

Endoprosthetic replacement for tumour of the proximal humerus using this prosthesis is a reliable operation yielding good functional results without the documented problems of unconstrained prostheses. The performance of this prosthesis is expected to improve further with the new constrained humeral liner.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 88 - 88
1 Jun 2012
Hart A Satchithananda K Henckel J Cobb J Sabah S Skinner J Mitchell A
Full Access

Introduction

Metal Artefact Reduction Sequence (MARS) MRI is being increasingly used to detect soft tissue inflammatory reactions surrounding metal-on-metal hip replacements. The UK MHRA safety alert announced in April 2010 recommended cross-sectional imaging such as MRI for all patients with painful MOM hips. The terms used to describe the findings include bursae, cystic lesions and solid masses. A recently used term, pseudotumour, incorporates all of these lesions. We aimed to correlate the pattern of abnormalities on MRI with clinical symptoms.

Method

Following our experience with over 160 MARS MRI scans of patients with MOM hips we recognized patterns of lesions according to their: wall thickness, T1/T2 signal, shape, and location. We categorised the 79 lesions from 159 MARS MRI scans of into our novel classification scheme of 1, 2a, 2b and 3. There were two groups of patients: well functioning and painful.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 43 - 43
1 Jun 2012
Dhinsa B Jalgaonkar A Nawaz Z Briggs T Muirhead-Allwood S Carrington R Skinner J Bentley G Miles J
Full Access

Patients with osteochondrodysplasia frequently require Total Hip Arthroplasty at a younger age, as a result of early degenerative disease of the hip joint. The outcome of Modular Total Hip Arthroplasty in this group of patients has been reported previously. In this retrospective study we evaluated the outcome of custom made (CADCAM) Total Hip Arthroplasty in patients with osteochondrodysplasia.

Between 1974 and 2009, twenty one CADCAM Total Hip Arthroplasty procedures were performed in fourteen patients in our institution. There were eight female and six male patients, with the mean age at time of surgery of 40.95 years (20 to 78). The patients were followed up clinically and with the Harris hip score for a mean of 7.12 years (0.5 to 17 years).

Four of the twenty-one hips (23.8%) required revision surgery at a mean of 11.54 years (6.5 to 17 years); one required it for aseptic loosening of the femoral component; one required complete revision of the acetabular component; one required exchange of acetabular liner; and one was for symptomatic non-union of a lesser trochanter avulsion.

This study shows encouraging clinical outcomes of custom made (CADCAM) Total Hip Arthroplasty in patients with osteochondrodysplasia,


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 211 - 211
1 Jun 2012
Sheeraz A Picardo N Mann B Skinner J
Full Access

Introduction

Melorheostosis is a rare bone dysplasia characterized by its classic radiographic appearance resembling dripping candle wax. The condition was originally described by Leri and Joanny in 1922. Its etiology is not fully known and treatment in most instances has been symptomatic. There are nearly 350 reported cases on melorheostosis, joint replacement has been successfully attempted in the shoulder and knee joint. We describe a case of severe melorheostosis affecting the left hip causing secondary osteo-arthritis, which was treated with a total hip replacement (THR). To the best of our knowledge this is the first reported case of its kind in the World literature.

Case history

A 52-year-old male of Indian origin with known melorheostosis of the left leg for over 30 years, presented with symptoms suggestive of severe osteo-arthritis of the left hip. Previously he had been treated for melorheostosis of the knee joint (fig 1a & 1b) with excisions and decompression of the medial femoral condyle. His left hip became more painful over the last few years. He had a fixed flexion deformity of 20° of the hip, severe muscle wasting and the affected leg was 3 cm longer than the right leg. Radiographs (fig 2a & 2b) confirmed the presence of sclerotic new bone in the acetabulum eroding the femoral head. He had the classical dripping candle wax appearance along the medial border of the neck and shaft of the femur. He underwent a THR using a Corail-Pinnacle un-cemented prosthesis using ceramic on polyethylene bearing surfaces (fig 3a & 3b). Post operatively he made a quick recovery and there was a marked improvement in his symptoms and functional outcome scores at 6 weeks.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 95 - 95
1 Jun 2012
Hua J Muirhead-Allwood S Sandiford A Skinner J Walker P
Full Access

Total hip replacements have shown great benefits to patients through relief of pain and restoration of function. However, because of the extensive variation in the size and shape of the femoral canal, especially for the situation encountered in the revision hip arthroplasty, standard uncemented hip systems with a limited number of sizes are unable to provide an accurate fit in every case. This study showed clinical results of 112 primary total hip replacements and 158 revision total hip replacements, using custom made CAD-CAM (Computer Aided Design-Computer Aided Manufactured) hip prostheses inserted between 1992 and 1998.

For primary hip replacements, the implants were designed to produce proximal line-to-line fit with the femoral bone and to provide optimal biomechanical environment of the hip. The stem was HA coated, 53 males and 58 females were included. Mean age was 46.2 years (range 24.6yrs - 62.2 yrs). The average duration of the follow up was 24 years (10 – 17 years). The mean Harris Hip Score (HHS) was improved from 42.4 to 90.3, mean Oxford Hip Score (OHS) was improved from 43.1 to 18.2 and the mean WOMAC hip score was improved from 57.0 to 11.9. There was 1 revision due to failure of the acetabular components but there were no failures of the femoral components. In the whole follow-up period, the survival of the femoral stem alone was 100%.

For revision hip replacements, the implants were designed using our design strategies of graduate approach to different revision situation based on Paprosky's classification of femoral bone defect. The implants were HA coated; some of them had distal cutting flutes. A total of 158 patients (97 males and 61 females) who had operation between 1991 and 1998 were followed up, among them 138 cases were due to aseptic loosening, 6 cases were periprosthetic fractures and 14 cases were infection. The average age was 63.1 years (range 34.6 – 85.9 years). The minimum follow up was 10 years (range 10 – 12 years). The mean Harris Hip Score was improved from 44.2 to 89.3, mean Oxford Hip Score was improved from 41.1 to 18.2 and the mean WOMAC hip score was improved from 52.4 to 12.3 respectively. 6 cases required further revision surgery, among them 3 were due to aseptic implant loosening, the overall survivorship at ten years was 97%.

The CAD-CAM hip stems are able to provide optimal implant fixation and restore hip function for every patient regardless their original femoral shape, bone condition and biomechanics of the hip. The excellent medium to long term clinical results justifies the use of CAD-CAM custom hip stems.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 89 - 89
1 Jun 2012
Hart A Quinn P Nolan J Tucker K Skinner J Powell J Lali F Mosselmans F
Full Access

Summary

We report the first use of synchrotron xray spectroscopy to characterize and compare the chemical form and distribution of metals found in tissues surrounding patients with metal-on-metal hip replacements that failed with (Ultima hips) or without (current generation, large diameter hips) corrosion.

Introduction

The commonest clinical category of failure of metal-on-metal (MOM) hip replacements is “unexplained” and commonly involved a soft tissue inflammatory response. The mechanism of failure of the Ultima MOM total hip replacement includes severe corrosion of the metal stem and was severe enough to be removed from clinical use. Corrosion is not a feature that we have found in the currently used MOM bearings. To better understand the biological response to MOM wear debris we hypothesized that tissue from failed hips with implant corrosion contained a different type of metal species when compared to those without corrosion.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 76 - 76
1 Jun 2012
Gokaraju K Miles J Blunn G Unwin P Pollock R Skinner J Tillman R Jeys L Abudi A Briggs T
Full Access

Non-invasive expandable prostheses for limb salvage tumour surgery were first used in 2002. These implants allow ongoing lengthening of the operated limb to maintain limb-length equality and function while avoiding unnecessary repeat surgeries and the phenomenon of anniversary operations.

A large series of skeletally immature patients have been treated with these implants at the two leading orthopaedic oncology centres in England (Royal National Orthopaedic Hospital, Stanmore, and Royal Orthopaedic Hospital, Birmingham).

An up to date review of these patients has been made, documenting the relevant diagnoses, sites of tumour and types of implant used. 87 patients were assessed, with an age range of 5 to 17 years and follow up range of up to 88 months.

Primary diagnosis was osteosarcoma, followed by Ewing's sarcoma. We implanted distal femoral, proximal femoral, total femoral and proximal tibial prostheses. All implants involving the knee joint used a rotating hinge knee. 6 implants reached maximum length and were revised. 8 implants had issues with lengthening but only 4 of these were identified as being due to failure of the lengthening mechanism and were revised successfully. Deep infection was limited to 5% of patients.

Overall satisfaction was high with the patients avoiding operative lengthening and tolerating the non-invasive lengthenings well. Combined with satisfactory survivorship and functional outcome, we commend its use in the immature population of long bone tumour cases.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 103 - 103
1 Jun 2012
Jalgaonkar A Mohan A Park D Dawson-Bowling S Aston W Cannon S Skinner J Briggs T
Full Access

There is very limited literature available on the use of prosthetic replacement in the treatment of primary and secondary tumours of the radius. In the past these were treated with vascularised and non-vascularised autografts which had associated donor site morbidity, problems of non union, graft or junctional fractures and delayed return to function. Our study is a mid to long term follow-up of implant survivorship and the functional outcome of metal prosthetic replacement used for primary and metastatic lesions of radius. We had 15 patients (8 males:7 females) with a mean age of 53 years. 8 patients underwent proximal radial replacement, 2 with mid-shaft radial replacement and 6 patients had distal radial replacements with wrist arthrodesis. The indications for replacement included metastatic lesions from renal cell carcinoma, primary giant cell tumours, ewings' sarcoma, chondroblastoma, radio-ulnar synostosis and benign fibrous histiocytoma. The average follow up was 5 years and 6 months (range 3 months - 18 years). Four patients died as a result of dissemination of renal cell carcinoma and two patients were lost to follow-up. There were no complications with the prosthesis or infection. Clinically and radiographically there was no loosening demonstrated at 18 years with secure fixation of implants. Two patients developed interossoeus nerve palsies which partially recovered. Functional outcomes of the elbow were assessed using the Mayo performance score with patients achieving a mean score of 85 postoperatively (range 65-95). All but one patient had full range of motion of the elbow. The patient with radio-ulnar synostosis had a 25 degree fixed flexion pot-operatively. Although the distal radial replacements had decreased range of movements of the wrist due to arthrodesis, they had excellent functional outcomes. Only one patient required revision surgery due to post-traumatic loosening of the implant. Our results of the use of endoprosthetic replacement of radius in the treatment of tumours are encouraging with regards to survivorship of the implant and functional outcome. This type of treatment results in an early return to daily routine activties, good functional outcome and patient satisfaction.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 44 - 44
1 Jun 2012
Dhinsa B Nawaz Z Gallagher K Carrington R Skinner J Briggs T Bentley G
Full Access

Purpose

The rate of arthroplasty or osteotomy in patients who had undergone autologous chondrocyte implantation (ACI) for osteochondral defects in the knee was determined. Furthermore, we investigated whether any radiographic evidence of osteoarthritis (OA) prior to ACI was associated with poorer outcome following surgery.

Methods

We retrospectively reviewed the medical notes and radiographs of 236 patients (mean age 34.9) who underwent ACI from 1998 to 2005 at our institution. Knee function was assessed according to the Modified Cincinnati Score (MCS) pre-operatively and at a mean of 64.3 months postoperatively (range 12 – 130). Radiographic changes were graded according to the Stanmore grading system.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 131 - 131
1 Jun 2012
Macmull S Bartlett W Miles J Blunn G Pollock R Carrington R Skinner J Cannon S Briggs T
Full Access

Polymethyl methacrylate spacers are commonly used during staged revision knee arthroplasty for infection. In cases with extensive bone loss and ligament instability, such spacers may not preserve limb length, joint stability and motion.

We report a retrospective case series of 19 consecutive patients using a custom-made cobalt chrome hinged spacer with antibiotic-loaded cement. The “SMILES spacer” was used at first-stage revision knee arthroplasty for chronic infection associated with a significant bone loss due to failed revision total knee replacement in 11 patients (58%), tumour endoprosthesis in four patients (21%), primary knee replacement in two patients (11%) and infected metalwork following fracture or osteotomy in a further two patients (11%). Mean follow-up was 38 months (range 24–70). In 12 (63%) patients, infection was eradicated, three patients (16%) had persistent infection and four (21%) developed further infection after initially successful second-stage surgery. Above knee amputation for persistent infection was performed in two patients.

In this particularly difficult to treat population, the SMILES spacer two-stage technique has demonstrated encouraging results and presents an attractive alternative to arthrodesis or amputation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 65 - 65
1 May 2012
Hart A Lloyd G Sabah S Sampson B Underwood R Cann P Henckel J Cobb PJ Lewis A Porter M Muirhead-Allwood S Skinner J
Full Access

SUMMARY

We report a prospective study of clinical data collected pre, intra and post operation to remove both cup and head components of 118 failed, current generation metal on metal (MOM) hips. Whilst component position was important, the majority were unexplained failures and of these the majority (63%) had cup inclination angles of less than 55 degrees. Poor biocompatibility of the wear debris may explain many of the failures.

BACKGROUND

Morlock et al reported a retrospective analysis of 267 MOM hips but only 34 head and cup couples (ie most were femoral neck fractures) and without data necessary to define cause of failure. The commonest cause of failure in the National Joint Registry (NJR) is unexplained.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 50 - 50
1 May 2012
Underwood RJ Cann PM Skinner J Hart A
Full Access

SUMMARY

The relationship between component position, wear rate and edge loading was investigated for 115 explanted current generation Metal-on-Metal (MoM) hips. Edge wear was detected in: 63% of all hips; and 48% of those with cups positioned within Lewinnek's box.

BACKGROUND

The link between steeply inclined cups (>55 degrees) and edge loading is known for all common hip bearing couples. Edge loading is associated with high rates of wear, and has been linked to premature failure of hips.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 28 - 28
1 May 2012
Masters J Sandison A Diss T Lali F Skinner J Hart A
Full Access

Metal-on-metal (MOM) hip resurfacings release chromium and cobalt wear debris into the surrounding joint. The hip tissue taken from failed MOM hips shows specific histological features including a subsurface band-like infiltrate of macrophages with particulate inclusions, perivascular lymphocytic infiltrate and fibrin exudation. This tissue response has been called Aseptic Lymphocytic Vasculitis Associated Lesion (ALVAL).

There is a recognised carcinogenic potential associated with hexavalent chromium and epidemiological data from first generation MOM arthroplasties may suggest an increased incidence of haematological malignancy. The ALVAL type reaction includes a marked proliferation of lymphocytes in the perivascular space and thorough investigation of this lymphocytic response is warranted.

This study aims to further characterise the lymphocytic infiltrate using immunohistochemistry and to test clonality using polymerase chain reaction (PCR).

Tissues from revised all cause failed MOM hip arthroplasties (n=77) were collected and analysed initially using routine H&E staining. Those that met the diagnostic criteria of ALVAL described above (n=34) were further stained with a panel of immunohistochemical markers (CD3, CD4, CD8 (T-cell markers) and CD20 (B-cell marker)). 10 representative ALVAL cases were selected and sent for gene rearrangement studies using PCR to determine whether the lymphocytes were polyclonal or monoclonal in nature.

The analysis of the lymphocytic aggregates in ALVAL, showed a mixed population of B and T cells. Within the aggregates, there was a predominance of B cells (CD20) over T cells (CD3). Of the 10 cases which were analysed by PCR, 7 were suitable for interpretation. None of these cases showed evidence of monoclonal lymphocyte proliferation.

The carcinogenic potential of wear debris from MOM hips, particularly affecting the haematopoietic system should be investigated. This study has shown a predominantly B-lymphocyte response in tissues surrounding MOM hips which is polyclonal. Although the numbers are small, the study suggests an immune mediated response in MOM hip tissue and excludes a neoplastic proliferation.

However, long term follow up of patients with MOM hips may be prudent.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 131 - 131
1 Mar 2012
Jaiswal P Park D Carrington R Skinner J Briggs T Flanagan A Bentley G
Full Access

Introduction

We report the initial 2 and 3 year follow-up results of this randomised controlled trial of autologous chondrocyte implantation (ACI) using porcine-derived collagen membrane as a cover (ACI-C) versus matrix-carried autologous chondrocyte implantation (MACI) for the treatment of osteochondral defects of the knee.

Methods

217 patients were randomised to have either ACI (92 patients) or MACI (125 patients). The mean age in each group was 35.1 and 33 years respectively. There were equal proportion of males and females and there was no difference in the size of lesions in each of the treatment groups. One year following surgery, patients underwent check arthroscopy (with or without biopsy) to assess the graft. Functional assessment was performed yearly by using the Modified Cincinatti Knee score, the SF-36 score, the Bentley Functional Rating Score and the Visual Analogue Score.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 155 - 155
1 Feb 2012
Krishnan S Skinner J Jaggiello J Carrington R Flanagan A Briggs T Bentley G
Full Access

Aims

To investigate (1) The relationship between macroscopic grading and durability of cartilage repair following collagen-covered autologous chondrocyte implantation (ACI-C) in the knee; (2) The influence of histology on durability of cartilage repair; (3) The relationship between macroscopic appearance and histology of repair tissue.

Patients and methods

The modified Cincinnati scores (MCRS) of eighty-six patients were evaluated prospectively at one year and at the latest follow-up (mean follow-up = 4.7yrs. Range = 4 to 7 years). Needle biopsies of their cartilage repair site were stained with Haematoxylin and Eosin and some with Safranin O and the neo-cartilage was graded as hyaline-like (n=32, 37.2%), mixed fibro-hyaline (n=19, 22%) and fibro-cartilagenous tissue (n=35, 40.7%). Macroscopic grading of the repair tissue using the international cartilage repair society grading system (ICRS) was available for fifty-six patients in the study cohort. Statistical analyses were performed to investigate the significance of histology and ICRS grading on MCRS at 1 year and at the latest follow-up.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 83 - 83
1 Feb 2012
Hart A Hester T Goodship A Powell J Pele L Fersht N Skinner J
Full Access

It is thought that metal ions from metal on metal bearing hip replacements cause DNA damage and immune dysfunction in the form of T cell mediated hypersensitivity. To explore the hypothesis that there is a relationship between metal ion levels and DNA damage and immune dysfunction in matched patient groups of hip resurfacings and standard hip replacements reflected in the levels of lymphocyte subtypes (CD3+ T cells, CD4+ T helper cells, CD8 +T cytotoxic/suppressor cells, CD16 +Natural Killer and CD19+ B cells) in peripheral blood samples, we analysed peripheral blood samples from 68 patients: 34 in the hip resurfacing group and 34 in the standard hip arthroplasty group. Samples were analysed for counts of each sub-group of lymphocyte and cytokine production. Whole blood cobalt and chromium ion levels were measured using inductively-coupled mass spectrometry. All hip components were well fixed.

Cobalt and chromium levels were significantly elevated in the resurfacing group compared to the hybrid group (p<0.001). There was a statistically significant decrease in the resurfacing group's level of CD8+ cells (T cytotoxic/suppressor) (p=0.010). No other subgroup of lymphocytes was significantly affected. Gamma interferon levels post antigen challenge were severely depressed in the hip resurfacing group.

A threshold level of blood cobalt and chromium ions for depression of CD8+ T cells was observed. Hip resurfacing patients have levels above this threshold whilst standard hip replacements fall below it. The patients all had normal levels of CD16 +Natural Killer and CD19+ B cells suggesting that this is not a bone marrow toxic effect. Cytokine analysis confirmed that some aspects of T cell function in hip resurfacing patients are severely depressed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 153 - 153
1 Feb 2012
Park D Krishnan S Skinner J Carrington R Flanagan A Briggs T Bentley G
Full Access

Purpose

We report on minimum 2 year follow-up results of 71 patients randomised to autologous chondrocyte implantation (ACI) using porcine-derived collagen membrane as a cover (ACI-C) and matrix-induced autologous chondrocyte implantation (MACI) for the treatment of osteochondral defects of the knee.

Introduction

ACI is used widely as a treatment for symptomatic chondral and osteochondral defects of the knee. Variations of the original periosteum-cover technique include the use of porcine-derived type I/type III collagen as a cover (ACI-C) and matrix-induced autologous chondrocyte implantation (MACI) using a collagen bilayer seeded with chondrocytes.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 154 - 154
1 Feb 2012
Rogers B Jagiello J Carrington S Skinner J Briggs T
Full Access

Introduction

The treatment of distal femoral cartilage defects using autologous chondrocyte implantation (ACI) and matrix-guided autologous chondrocyte implantation (MACI) is become increasingly common. This prospective 7-year study reviews and compares the clinical outcome of ACI and MACI.

Methods

We present the clinical outcomes of 159 knees (156 patients) that have undergone autologous chondrocyte implantation from July 1998. One surgeon performed all operations with patients subsequently assessed on a yearly basis using 7 independent validated clinical, functional and satisfaction rating scores.