header advert
Results 51 - 100 of 128
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 4 - 4
1 Jan 2016
MacDonald D Clarkin-Wright G Parvizi J Lee G Klein G Rimnac C Gilbert J Kurtz S
Full Access

Introduction

In THA, fretting corrosion at the head-stem taper junction has emerged as a clinical concern that may result in adverse local tissue reactions, even in patients with a metal-on-polyethylene bearing [1]. Taper junctions that employ a ceramic head have demonstrated reduced corrosion at the interface [2]. However, during revision surgery with a well-fixed stem, a titanium sleeve is used in conjunction with a ceramic head to ensure proper fit of the head onto the stem and better stress distribution. In vitro testing has suggested that corrosion is not a concern in sleeved ceramic heads [3]; however, little is known about the in vivo fretting corrosion of the sleeves. The purpose of this study was to investigate fretting corrosion in sleeved ceramic heads.

Materials and Methods

Between 2001 and 2014, 35 sleeved ceramic heads were collected during revision surgery as part of a multi-center retrieval program. The sleeves were all fabricated from titanium alloy and manufactured by 4 companies (CeramTec (n=14), Smith & Nephew (Richards, n=11), Stryker (n=5), and Zimmer (n=5)). The femoral heads were made from 3 ceramics (Alumina (n=7), Zirconia (n=11), and Zirconia-toughened Alumina (n=17)). Sleeve dimensions (length and thickness) were measured using calibrated calipers. Fretting corrosion of the sleeves and available associated stems was scored using a 4-point, semi-quantitative scoring system [4], with 1 being little-to-no damage, and 4 corresponded to severe fretting corrosion. Five sleeves could not be extracted; thus the external surface was not scored.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 28 - 28
1 Jan 2016
Hanzlik J Day J Levine HB Klein GR Hartzband M Parvizi J Kraay M Rimnac C Kurtz S
Full Access

Introduction

A variety of porous coatings and substrates have been used to obtain fixation at the bone-implant interface. Clinical studies of porous tantalum, have shown radiographically well-fixed implants with limited cases of loosening. However, there has been limited retrieval analysis of porous tantalum hip implants. The purpose of this study was to investigate factors affecting bone ingrowth into porous tantalum hip implants.

Methods

126 porous tantalum acetabular shells and 7 femoral stems, were collected under an IRB-approved multicenter retrieval program. Acetabular shells that were grossly loose, cemented or complex revisions were excluded. Shells with visible bone on the surface were chosen. 20 acetabular shells (10 primary) and all femoral stems were dehydrated, embedded, sectioned, polished and bSEM imaged (Figure-1). Main shell revision reasons were infection (n=10,50%), femoral loosening (n=3,15%) and instability (n=3,15%). Analyzed implants were implanted for 2.3±1.7 years (shells) and 0.3±0.3 years (stems). Eight slices per shell and 5–7 slices per stem were analyzed. The analysis included bone area/pore area (BA/PA), BA/PA zonal depth analysis, extent of ingrowth and maximum depth of bone ingrowth. BA/PA zone depths were: Zone-1 (0–500um), Zone-2 (500–1000um) and Zone-3 (1000um-full depth). Nonparametric statistical tests investigated differences in bone measurements by location within an implant and implant type (Friedman's Variance and Kruskal-Wallis). Post-hoc Dunn tests were completed for subsequent pairwise comparisons. Spearman's rank correlation identified correlations between bone measurements and patient related variables (implantation time, age, height, weight, UCLA Activity Score). Statistical analyses were performed using PASW Statistics package.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 18 - 22
1 Jan 2016
Heller S Rezapoor M Parvizi J

The purpose of this article is to provide the reader with a seven-step checklist that could help in minimising the risk of PJI. The check list includes strategies that can be implemented pre-operatively such as medical optimisation, and reduction of the bioburden by effective skin preparation or actions taking during surgery such as administration of timely and appropriate antibiotics or blood conservation, and finally implementation of post-operative protocols such as efforts to minimise wound drainage and haematoma formation.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):18–22.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 132 - 132
1 Jan 2016
MacDonald D Kurtz SM Kocagoz S Hanzlik J Underwood RJ Gilbert J Lee G Mont M Kraay M Klein GR Parvizi J Day J Rimnac C
Full Access

Introduction

Recent implant design trends have renewed concerns regarding metal wear debris release from modular connections in THA. Previous studies regarding modular head-neck taper corrosion were largely based on cobalt chrome (CoCr) alloy femoral heads. Comparatively little is known about head-neck taper corrosion with ceramic femoral heads or about how taper angle clearance influences taper corrosion. This study addressed the following research questions: 1) Could ceramic heads mitigate electrochemical processes of taper corrosion compared to CoCr heads? 2) Which factors influence stem taper corrosion with ceramic heads? 3) What is the influence of taper angle clearance on taper corrosion in THA?

Methods

100 femoral head-stem pairs were analyzed for evidence of fretting and corrosion. A matched cohort design was employed in which 50 ceramic head-stem pairs were matched with 50 CoCr head-stem pairs based on implantation time, lateral offset, stem design and flexural rigidity. Fretting corrosion was assessed using a semi-quantitative scoring scale where a score of 1 was given for little to no damage and a score of 4 was given for severe fretting corrosion. The head and trunnion taper angles were measured using a roundness machine (Talyrond 585, Taylor Hobson, UK). Taper angle clearance is defined as the difference between the head and trunnion taper angles.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 26 - 26
1 Jan 2016
Arnholt C Kocagoz S MacDonald D Gilbert J Parvizi J Malkani AL Klein GR Kraay M Rimnac C Kurtz S
Full Access

Introduction

The release of metal debris and ions has raised concerns in joint arthroplasty. In THA metal debris and ions can be generated by wear of metal-on-metal bearing surfaces and corrosion at modular taper interfaces, currently understood to be mechanically assisted crevice corrosion (MACC) [1]. More recently, inflammatory-cell induced corrosion (ICIC) has been identified as a possible source of metal debris and/or ions [2]. Although MACC has been shown to occur at modular junctions in TKA, little is known about the prevalence of other sources. The purpose of this study was to determine the sources of metallic debris and ion release in long-term implanted (in vivo > 15y) TKA femoral components. Specific attention was paid to instances of ICIC as well as damage at the implant-bone interface.

Methods

1873 retrieved TKA components were collected from 2002–2013 as part of a multi-center, IRB-approved retrieval program. Of these, 52 CoCr femoral condyles were identified as long term TKA (Average: 17.9±2.8y). These components were predominantly revised for loosening, PE wear and instability. 40/52 of the components were primary surgeries. Components were examined using optical microscopy to confirm the presence of 5 damage mechanisms (polyethylene failure, MACC corrosion of modular tapers, corrosion damage between cement and backside, third-body wear, and ICIC). Third-body wear was evaluated using a semi-quantitative scoring method based on the percentage of damaged area. A score of 1 had minimal damage and a score of 4 corresponded to severe damage. Polyethylene components were scored using the Hood method and CoCr components were scored similarly to quantify metal wear. The total area damaged by ICIC was quantified using photogrammetry. Images were taken using a digital SLR with a calibrated ruler in the same focal plane. Using known pixel dimensions, the ICIC damaged area was calculated.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 53 - 53
1 Dec 2015
Tan T Manrique J Gomez M Chen A Parvizi J
Full Access

It is strongly recommended that tissue and synovial fluid culture samples be obtained during reimplantation performed as part of a two-stage exchange arthroplasty. The incidence of positive cultures during reimplantation and the influence of positive cultures on subsequent outcome are unknown. This aim of this study was to determine the incidence of positive cultures during reimplantation and to investigate the association between positive cultures at reimplantation and the subsequent outcome

A retrospective review was conducted on 267 patients that met the Musculoskeletal Infection Society (MSIS) criteria for PJI that completed both stages of two-stage exchange arthroplasty (Table 1). Intraoperative culture results from tissue and/or synovial fluid were obtained. Cultures were positive in 33 cases (12.4%) undergoing reimplantation surgery (Figure 1). Treatment failure was assessed based on the Delphi consensus definition. Logistic regression analysis was performed to assess the predictors of positive culture and risk factors for failure of two-stage exchange arthroplasty.

Treatment failure was 45.5% for those with a positive intraoperative culture and 20.9% in those with negative cultures at the time of reimplantation. When controlling for organism virulence, comorbidities, and other confounding factors, treatment failure was higher (odds ratio [OR]: 3.3; 95% confidence interval [CI]: 1.3–4.5) and occurred at an earlier time point (hazard ratio: 2.5; 95% CI: 1.3–4.5) in patients with a positive reimplantation culture. The treatment failure rate was not different between cases with two or more positive cultures (36.4%) and one positive culture (42.8%).

Positive intraoperative cultures during reimplantation, regardless of the number of positive samples were independently associated with two times the risk of subsequent infection and earlier treatment failure. Surgeons should be aware that a positive culture at the time of reimplantation independently increases the risk of subsequent failure and needs to be taken seriously. Given the significance of these findings, future studies are needed to evaluate the optimal management of positive cultures during reimplantation surgery.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 58 - 58
1 Dec 2015
Tan T Maltenfort M Chen A Shahi A Madden A Parvizi J
Full Access

Considerable efforts have been invested into identifying risk factors for periprosthetic joint infection (PJI) after total joint arthroplasty (TJA). Preoperative identification of risk factors for developing PJI is imperative for medical optimization and targeted prophylaxis. The purpose of this study was to create a preoperative risk calculator for PJI by assessing a patient's individual risks for developing PJI with resistant organisms and S.aureus.

A retrospective review of 27117 patients (43253 TJAs) from 1999 to 2014, including 1035 PJIs, was performed. A total of 41 risk factors including demographics, comorbidities (using the Elixhauser and Charlson Index), and the number of previous TJAs, were evaluated. Multivariate analysis was performed; coefficients of the models were scaled to produce useful integer scoring. Predictive model strength was assessed employing area under the curve (AUC) analysis.

Among the 41 assessed variables, the following were significant risk factors in descending order of significance: prior surgeries (p<0.0001), drug abuse (p=0.0003), revision surgery (p<0.0001), human immunodeficiency virus (p=0.0004), coagulopathy (p<0.0001), renal disease (p<0.0001), congestive heart-failure (p<0.0001), psychoses (p=0.0024), rheumatological disease (p<0.0001), knee involvement (p<0.0001), diabetes (p<0.0001), anemia (p<0.0001), males (p<0.0001), liver disease (p=0.0093), smoking (p=0.0268), and high BMI (p<0.0001). Furthermore, presence of heart-valve disease (p=0.0409), metastatic disease (p=0.0006), and pulmonary disease (p=0.0042) increased the resistant organism PJIs. Patients with metastatic disease were also more likely to be infected with S. aureus (p=0.0002). AUCs were 0.83 for any PJI, 0.86 for resistant PJI, and 0.84 for S.aureus PJI models.

This large-scale single-institutional study has determined various risk factors for PJI. Some factors are modifiable and need to be addressed before elective arthroplasty. It is imperative that surgeons are aware of these risk factors and implement all possible preventative measures, including targeted prophylaxis, in patients with high-risk of PJI. Continued efforts are needed to find novel and effective solutions to minimize the burden PJI.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 59 - 59
1 Dec 2015
Tan T Springer B Parvizi J Chen A
Full Access

Perioperative antibiotic prophylaxis remains one of the most important strategies for prevention of periprosthetic joint infection (PJI) with current guideline recommending a first or second generation cephalosporin. Penicillin (PCN) allergy is often reported by patients, which often results in avoidance of administration of cephalosporins due to fear of cross-reactivity. Alternative medications, such as vancomyin, are often used despite reduced antimicrobial coverage. The purpose of this study was to determine if PCN allergic patients who received vancomycin alone prior to elective primary total joint arthroplasty were at increased risk of developing a subsequent PJI.

A retrospective review of 7,602 primary total joint arthroplasties (TJAs) performed between 2005 and 2013 in two institutions were identified using a prospective institutional database. Patient reported PCN or cephalosporin allergy was electronically queried from the anesthesia note. Patients who recieved multiple prophylactic antibiotics, or had unavailable perioperative antibiotic information, or those who received medication other than cefazolin and vancomycin were excluded. PJI was determined using a cross-match with an institutional PJI database constructed from International Classification of Diseases (ICD)-9 codes. Logistic regression analysis was then performed to evaluate the risk of subsequent PJI.

The rate of PJI was 1.4% (32/2296) in patients with a reported PCN allergy that received vancomycin alone versus 1.1% (59/5306) in non-PCN allergic patients that received cefazolin alone. The multivariate analysis, with the given sample size, did not detect a statistically significant increased risk of PJI when vancomycin was administered alone (adjusted odds ratio: 1.23, 95% CI 0.6–3.1, p=0.35). While there was no significant differences in the organism profile between PJIs in both groups, the rate of PJI caused by resistant organisms was higher in patients who received vancomycin alone (11.9%, 7/59) compared to those who received cefazolin (3.1%, 1/32).

While administration of perioperative prophylactic vancomycin alone during elective primary arthroplasty does not seem to result in a higher rate of subsequent PJI, patients who received vancomycin alone and developed a PJI were more likely to develop an infection with an antibiotic resistant organism. Future studies are needed to determine the most appropriate prophylactic antibiotic for patients who undergo elective arthroplasty and report PCN allergy.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 56 - 56
1 Dec 2015
Shahi A Tan T Chen A Maltenfort M Parvizi J
Full Access

Periprosthetic joint infection (PJI) is one of the most devastating complications of total joint arthroplasty (TJA). Only a few studies have investigated PJI's impact on the most worrisome of all endpoints, mortality. The purpose of this study was to perform a large-scale study to determine the rates of PJI associated in-hospital mortality, and compare it to other surgical procedures.

The Nationwide Inpatient Sample was queried from 2002 to 2010 to assess the risk of mortality for patients undergoing revision for PJI or aseptic failures. Elixhauser comorbidity index and ICD-9 codes were used to obtain patients’ medical conditions and identify PJI. Multiple logistic-regression analyses were used to determine the associated variables with mortality. In-hospital mortality was compared to the followings: coronary-artery bypass graft, mastectomy, prostatectomy, appendectomy, kidney transplant, carotid surgery, cholecystectomy, and coronary interventional procedures.

PJI was associated with an increased risk (odds ratio 2.04) of in-hospital mortality (0.77%) compared to aseptic revisions (0.38%). The in-hospital mortality of revision THAs done for PJI (1.38%, 95%CI, 1.12–1.64%) was comparable to or higher than interventional coronary procedure (1.22%, 95%CI, 1.20–1.24%), cholecystectomy (1.13%, 95%CI, 1.11–1.15%), kidney transplantation (0.70%, 95%CI, 0.61%–0.79%) and carotid surgery (0.89%, 95%CI, 0.86%–0.93%) (Figure 1). The following comorbidities were independent risk factors for in-hospital mortality after TJA: liver disease, metastatic disease, fluid and electrolyte disorders, coagulopathy, weight loss and malnutrition, congestive heart failure, pulmonary circulation disorder, renal failure, and peripheral vascular disease.

PJI is associated with a two-fold increase in mortality and have mortality rates comparable to kidney transplantation and carotid surgery. Considering the fact that patients with PJI often require multiple surgical procedures, the rate of actual in-hospital mortality for patients with PJI may be considerably higher. Surgeons should be cognizant of the potentially fatal outcome of PJI and must emphasize the importance of infection control to reduce the risk of mortality.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 55 - 55
1 Dec 2015
Gomez M Manrique J Tan T Chen A Parvizi J
Full Access

Failure of a two-stage exchange arthroplasty for management of periprosthetic joint infection (PJI) poses a major clinical challenge. There is a paucity of information regarding the outcome of further surgical intervention in these patients. Thus, we aim to report the clinical outcomes of subsequent surgical intervention following a failed prior two-stage exchange.

Our institutional database was used to identify 60 patients (42 knees and 18 hips) with a failed prior two-stage exchange from infection, who underwent further surgical intervention between 1998 and 2012 and had a minimum of two years follow-up. A retrospective review was performed to extract relevant clinical information, such as mortality, microbiology, and subsequent surgeries. Musculoskeletal Infection Society criteria were used to define PJI, and treatment success was defined using the Delphi criteria as previously reported.

Irrigation and debridement (I&D) was performed after a failed two-stage exchange in 61.7% (37/60) patients. The failure rate of I&D in this cohort was 51.3% (19/37). Two patients underwent amputation after I&D due to uncontrolled infection. A total of 40 patients underwent an intended a second two-stage exchange. Reimplantation occurred in only 65% of cases (26/40), and infection was controlled in 61.6% (16/26) of patients. An interim spacer exchange was required in 15% (6/40) of the cases. Of the 14 cases that did not undergo a second stage reimplantation, 5 required amputation, 6 had retained spacers, 1 underwent arthrodesis, and 2 patients died.

Further surgical intervention after a failed prior two-stage exchange has poor outcomes. I&D has a high failure rate and many of the patients who are deemed candidates for a second two-stage exchange either do not undergo reimplantation for various reasons or fail after reimplantation. The management of PJI clearly remains imperfect, and there is a dire need for further innovations that may improve the care of these PJI patients.


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 20 - 29
1 Oct 2015
Gehrke T Alijanipour P Parvizi J

Periprosthetic joint infection (PJI) is one of the most feared and challenging complications following total knee arthroplasty. We provide a detailed description of our current understanding regarding the management of PJI of the knee, including diagnostic aids, pre-operative planning, surgical treatment, and outcome.

Cite this article: Bone Joint J 2015;97-B(10 Suppl A):20–9.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1157 - 1158
1 Sep 2015
Parvizi J Haddad FS


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 116 - 116
1 Feb 2015
Parvizi J
Full Access

Periprosthetic joint infection (PJI) is one the most devastating complications of joint arthroplasty. Although PJI is an infrequent complication (the reported incidence is 1%-2% in the United States), it is the most common indication for revision total knee arthroplasty in the Medicare population and the third most frequent indication for revision total hip arthroplasty. Moreover, the prevalence of PJI appears to be on the rise, with a projected number exceeding 60,000 to 70,000 cases in the United States by 2023.

It is estimated that more than 25% of revision procedures annually are attributed to PJI and this number is expected to increase in the upcoming years. The increase in the prevalence of obesity, diabetes, and other comorbidities among the patient population and the emergence of resistant infecting organisms are some of the reasons for the expected rise in the number of infections that medical community will witness.

The challenges that PJI presents to the orthopaedic community are on many fronts. Prevention of PJI has proven to be a difficult task indeed. Effective strategies for prevention of PJI are being refined. The Center for Disease Control will be publishing its updated Surgical Site Prevention Guidelines in the next few months that consists of specific recommendations for prevention of PJI. In recent years, strides are made in introducing novel molecular techniques for diagnosis of PJI, which may stand to change our practices. The current surgical technique for management of PJI, besides the immense cost, fall short of delivering high success to the patients. The major problem in eradication of infection relates to formation of biofilm, on the implant surface and internalization of the organisms by affected cells. Biofilm is a sophisticated structure comprising of organisms embedded in multiple layers of glycoccalyx that allows the organisms to evade host immunity and is impenetrable to antibiotics. These organisms are capable or communicating through molecular mechanisms such as quorum sensing that affords them advantage for survival in the host environment. In recent years strategies to prevent colonization of the implant surface, an essential first step in formation of biofilm, or biofilm disruption techniques have been introduced. A recent International Consensus meeting on PJI that assembled more than 350 experts identified some of the best practices in this field and identified areas in need of future research. Moving into the future, the field of orthopaedics in general and PJI in particular stand to benefit from the discoveries in the field of molecular diagnostics, metabolomics and epigenetics.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 107 - 107
1 Feb 2015
Parvizi J
Full Access

Introduction:

The safety of simultaneous bilateral knee replacement (BTKA) remains controversial. Some studies have proposed a higher incidence of serious complications, even death, following BTKA whilst others refute the latter. The objective of this meta-analysis was to evaluate the safety of BTKA.

Methods:

A computerised literature search was conducted to identify all citations, between 1966 to 2005, concerning BTKA. All the English-language abstracts were obtained. A multistage assessment was then used to identify articles fulfilling the inclusion criteria for the study. All randomised, prospective studies reporting the outcome of BTKA were included. Details of any reported data were extracted and extensive analysis of relevant variables carried out.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 45 - 49
1 Jan 2015
Tokarski AT Novack TA Parvizi J

We hypothesised that the use of tantalum (Ta) acetabular components in revision total hip arthroplasty (THA) was protective against subsequent failure due to infection. We identified 966 patients (421 men, 545 women and 990 hips) who had undergone revision THA between 2000 and 2013. The mean follow up was 40.2 months (3 months to 13.1 years). The mean age of the men and women was 62.3 years (31 to 90) and 65.1 years (25 to 92), respectively.

Titanium (Ti) acetabular components were used in 536 hips while Ta components were used in 454 hips. In total, 73 (7.3%) hips experienced subsequent acetabular failure. The incidence of failure was lower in the Ta group at 4.4% (20/454) compared with 9.9% (53/536) in the Ti group (p < 0.001, odds ratio 2.38; 95% CI 1.37 to 4.27). Among the 144 hips (64 Ta, 80 Ti) for which revision had been performed because of infection, failure due to a subsequent infection was lower in the Ta group at 3.1% (2/64) compared with 17.5% (14/80) for the Ti group (p = 0.006).

Thus, the use of Ta acetabular components during revision THA was associated with a lower incidence of failure from all causes and Ta components were associated with a lower incidence of subsequent infection when used in patients with periprosthetic joint infection.

Cite this article: Bone Joint J 2015;97-B:45–9.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 154 - 154
1 Jul 2014
Kurtz S Zielinska O MacDonald D Cates H Mont M Malkani A Parvizi J Kraay M Rimnac C Klein G
Full Access

Summary Statement

This study assesses oxidation, mechanical behavior and revision reasons of 2nd generation HXLPE used in total hip and knee arthroplasty. While oxidation was low for both X3 and E1 HXLPEs, oxidative regional variations were detected in the sequentially annealed cohort.

Introduction

First generation highly crosslinked polyethylenes (HXPLEs) have proven successful in lowering both penetration and osteolysis rates. However, 1st generation annealing and remelting thermal stabilization have been associated with in vivo oxidation or reduced mechanical properties. Thus, 2nd generation HXLPEs were developed to improve oxidative stability while still maintaining material properties. Little is known about the in vivo clinical failure modes of these 2nd generation HLXPEs. The purpose of this study was to assess the revision reasons, wear, oxidative stability, and mechanical behavior of retrieved sequentially annealed Vitamin E diffused HXLPE in THA and TKA.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 145 - 145
1 Jul 2014
Kurtz S MacDonald D Higgs G Gilbert J Klein G Mont M Parvizi J Kraay M Rimnac C
Full Access

Summary Statement

Fretting and corrosion has been identified as a clinical problem in modular metal-on-metal THA, but remains poorly understood in modern THA devices with polyethylene bearings. This study investigates taper damage and if this damage is associated with polyethylene wear.

Introduction

Degradation of modular head-neck tapers was raised as a concern in the 1990s (Gilbert 1993). The incidence of fretting and corrosion among modern, metal-on-polyethylene and ceramic-on-polyethylene THA systems with 36+ mm femoral heads remains poorly understood. Additionally, it is unknown whether metal debris from modular tapers could increase wear rates of highly crosslinked PE (HXLPE) liners. The purpose of this study was to characterise the severity of fretting and corrosion at head-neck modular interfaces in retrieved conventional and HXLPE THA systems and its effect on penetration rates.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_12 | Pages 27 - 27
1 Jul 2014
Parvizi J
Full Access

Introduction

The safety of simultaneous bilateral knee replacement (BTKA) remains controversial. Some studies have proposed a higher incidence of serious complications, even death, following BTKA whilst others refute the latter. The objective of this meta-analysis was to evaluate the safety of BTKA.

Methods

A computerised literature search was conducted to identify all citations, between 1966 to 2005, concerning BTKA. All the English-language abstracts were obtained. A multistage assessment was then used to identify articles fulfilling the inclusion criteria for the study. All randomised, prospective studies reporting the outcome of BTKA were included. Details of any reported data were extracted and extensive analysis of relevant variables carried out.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_8 | Pages 29 - 29
1 May 2014
Parvizi J
Full Access

Developmental dysplasia of the hip (DDH) is relatively a common condition that can lead to early arthritis of the hip. Although total hip arthroplasty is the surgical treatment of choice for these patients with end stage arthritis, some patients afflicted with DDH may present early. Acetabular osteotomy, in particular Bernese or periacetabular osteotomy (PAO as described by Professor Ganz and Jeff Mast back in 1980s) may be an option with patients with symptomatic DDH who have joint space available. PAO has many advantages. First, it is performed through a single incision (modified Smith Peterson approach) without breaching the abductor mechanism. The periacetabular fragment has, hence, excellent blood supply and avascular necrosis of the acetabular portion is not an issue. In addition, the osteotomy is so versatile allowing for great mobility of the fragment to obtain coverage even in the worst of circumstances. The osteotomy does not affect the posterior column and hence allows for earlier weight bearing. Most joint preservation surgeons in North America and Europe prefer PAO to other types of osteotomy.

The indications for PAO are a patient with symptomatic DDH who has good joint space and a congruent joint. The congruency of the joint is usually determined by the abduction views (obtained at 30 degrees abduction and neutral rotation). Although the joint space may be measured on plain radiographs, in recent years some centers have been utilising cross sectional imaging, such as dGEMERIC for evaluation of the articular cartilage, which has been shown to be a good predictor of outcome for PAO.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 569 - 573
1 May 2014
Sullivan MP McHale KJ Parvizi J Mehta S

Nanotechnology is the study, production and controlled manipulation of materials with a grain size < 100 nm. At this level, the laws of classical mechanics fall away and those of quantum mechanics take over, resulting in unique behaviour of matter in terms of melting point, conductivity and reactivity. Additionally, and likely more significant, as grain size decreases, the ratio of surface area to volume drastically increases, allowing for greater interaction between implants and the surrounding cellular environment. This favourable increase in surface area plays an important role in mesenchymal cell differentiation and ultimately bone–implant interactions.

Basic science and translational research have revealed important potential applications for nanotechnology in orthopaedic surgery, particularly with regard to improving the interaction between implants and host bone. Nanophase materials more closely match the architecture of native trabecular bone, thereby greatly improving the osseo-integration of orthopaedic implants. Nanophase-coated prostheses can also reduce bacterial adhesion more than conventionally surfaced prostheses. Nanophase selenium has shown great promise when used for tumour reconstructions, as has nanophase silver in the management of traumatic wounds. Nanophase silver may significantly improve healing of peripheral nerve injuries, and nanophase gold has powerful anti-inflammatory effects on tendon inflammation.

Considerable advances must be made in our understanding of the potential health risks of production, implantation and wear patterns of nanophase devices before they are approved for clinical use. Their potential, however, is considerable, and is likely to benefit us all in the future.

Cite this article: Bone Joint J 2014; 96-B: 569–73.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 65 - 69
1 Jan 2014
Gutowski CJ Zmistowski BM Clyde CT Parvizi J

The rate of peri-prosthetic infection following total joint replacement continues to rise, and attempts to curb this trend have included the use of antibiotic-loaded bone cement at the time of primary surgery. We have investigated the clinical- and cost-effectiveness of the use of antibiotic-loaded cement for primary total knee replacement (TKR) by comparing the rate of infection in 3048 TKRs performed without loaded cement over a three-year period versus the incidence of infection after 4830 TKRs performed with tobramycin-loaded cement over a later period of time of a similar duration. In order to adjust for confounding factors, the rate of infection in 3347 and 4702 uncemented total hip replacements (THR) performed during the same time periods, respectively, was also examined. There were no significant differences in the characteristics of the patients in the different cohorts.

The absolute rate of infection increased when antibiotic-loaded cement was used in TKR. However, this rate of increase was less than the rate of increase in infection following uncemented THR during the same period. If the rise in the rate of infection observed in THR were extrapolated to the TKR cohort, 18 additional cases of infection would have been expected to occur in the cohort receiving antibiotic-loaded cement, compared with the number observed. Depending on the type of antibiotic-loaded cement that is used, its cost in all primary TKRs ranges between USD $2112.72 and USD $112 606.67 per case of infection that is prevented.

Cite this article: Bone Joint J 2014;96-B:65–9.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 386 - 386
1 Dec 2013
Kurtz S Zielinska O MacDonald D Cates H Mont M Malkani AL Parvizi J Rimnac C
Full Access

Introduction:

First generation highly crosslinked polyethylenes (HXPLEs) have proven successful in lowering both penetration and osteolysis rates. However, 1st generation annealing and remelting thermal stabilization have been associated with in vivo oxidation or reduced mechanical properties. Thus, 2nd generation HXLPEs were developed to improve oxidative stability while still maintaining material properties. Little is known about the in vivo clinical failure modes of these 2nd generation HLXPEs.

The purpose of this study was to assess the revision reasons, wear, oxidative stability, and mechanical behavior of retrieved sequentially annealed Vitamin E diffused HXLPE in THA and TKA.

Methods:

251 2nd Generation HXLPE hip and knee components were consecutively retrieved during revision surgeries and continuously analyzed in a prospective, IRB approved, multicenter study. 123 acetabular liners (Implanted 1.2y; Range 0–5.0y) and 117 tibial inserts (Implanted 1.6y; Range 0–5.8y) were highly crosslinked and annealed in 3 sequential steps (X3). Five acetabular liners (Implanted 0.6y; Range 0–2.0y) and six tibial inserts (Implanted 1.3y; Range 0.5–1.8y) were diffused with Vitamin E (E1). Patient information was collected from medical records (Table 1).

Linear penetration of liners was measured using a calibrated digital micrometer (accuracy: 0.001 mm). Surface damage of tibial components was assessed using the Hood method. Thin sections were taken from the acetabular liners (along the superior/inferior axis) and the tibial components (along the medial condyle and central spine) for oxidation analysis and analyzed according to ASTM 2102. Mechanical behavior was assessed via the small punch test (ASTM 2183).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 387 - 387
1 Dec 2013
Kurtz S MacDonald D Higgs G Gilbert J Klein GR Mont M Parvizi J Kraay M Rimnac C
Full Access

Introduction:

Degradation of modular head-neck tapers was raised as a concern in the 1990s (Gilbert 1993). The incidence of fretting and corrosion among modern, metal-on-polyethylene and ceramic-on-polyethylene THA systems with 36+ mm femoral heads remains poorly understood. Additionally, it is unknown whether metal debris from modular tapers could increase wear rates of highly crosslinked PE (HXLPE) liners.

The purpose of this study was to characterize the severity of fretting and corrosion at head-neck modular interfaces in retrieved conventional and HXLPE THA systems and its effect on penetration rates.

Patients & Methods:

386 CoCr alloy heads from 5 manufacturers were analyzed along with 166 stems (38 with ceramic femoral heads). Metal and ceramic components were cleaned and examined at the head taper and stem taper by two investigators. Scores ranging from 1 (mild) to 4 (severe) were assigned in accordance with the semi-quantitative method adapted from a previously published technique. Linear penetration of liners was measured using a calibrated digital micrometer (accuracy: 0.001 mm). Devices implanted less than 1 year were excluded from this analysis because in the short-term, creep dominates penetration of the head into the liner.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 110 - 110
1 Dec 2013
MacDonald D Kurtz S Kocagoz S Hanzlik J Underwood R Gilbert J Lee G Mont M Kraay M Klein GR Parvizi J Rimnac C
Full Access

Background:

Previous studies regarding modular head-neck taper corrosion were largely based on cobalt chrome (CoCr) alloy femoral heads. Less is known about head-neck taper corrosion with ceramic femoral heads.

Questions/purposes:

We asked (1) whether ceramic heads resulted in less taper corrosion than CoCr heads; (2) what device and patient factors influence taper fretting corrosion; and (3) whether the mechanism of taper fretting corrosion in ceramic heads differs from that in CoCr heads.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 45 - 45
1 Dec 2013
Deirmengian C Kardos K Kilmartin P Cameron A Chung D Booth R Parvizi J
Full Access

INTRODUCTION:

The diagnosis of periprosthetic joint infection (PJI) remains a serious challenge. Based on previous work, we believe that biomarkers will become the mainstay of diagnosing PJI in the future. We report on completion of our 8 year comprehensive biomarker program, evaluating the diagnostic profile of the 15 most promising synovial fluid biomarkers.

METHODS:

Synovial fluid was prospectively collected from 99 patients being evaluated for infection in the setting of revision hip or knee arthroplasty. All synovial fluid samples were tested by immunoassay for 15 putative biomarkers that were developed and optimized specifically for use in synovial fluid. Sensitivity, specificity and receiver operating Characteristic (ROC) curve analysis were performed for all biomarkers.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1450 - 1452
1 Nov 2013
Parvizi J Gehrke T Chen AF

Louis Pasteur once said that: “Fortune favours the prepared mind.” As one of the great scientists who contributed to the fight against infection, he emphasised the importance of being prepared at all times to recognise infection and deal with it. Despite the many scientific discoveries and technological advances, such as the advent of antibiotics and the use of sterile techniques, infection continues to be a problem that haunts orthopaedic surgeons and inflicts suffering on patients.

The medical community has implemented many practices with the intention of preventing infection and treating it effectively when it occurs. Although high-level evidence may support some of these practices, many are based on little to no scientific foundation. Thus, around the world, there is great variation in practices for the prevention and management of periprosthetic joint infection.

This paper summaries the instigation, conduct and findings of a recent International Consensus Meeting on Surgical Site and Periprosthetic Joint Infection.

Cite this article: Bone Joint J 2013;95-B:1450–2.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 133 - 134
1 Nov 2013
Parvizi J Diaz-Ledezma C

Total knee replacement (TKR) is an operation that can be performed with or without the use of a tourniquet. Meta-analyses of the available Level-1 studies have demonstrated that the use of a tourniquet leads to a significant reduction in blood loss. The opponents for use of a tourniquet cite development of complications such as skin bruising, neurovascular injury, and metabolic disturbance as drawbacks. Although there may certainly be reason for concern in arteriopathic patients, there is little evidence that routine use of a tourniquet during TKR results in any of the above complications. The use of a tourniquet, on the other hand, provides a bloodless field that allows the surgeon to perform the procedure with expediency and optimal visualisation. Blood conservation has gained great importance in recent years due to increased understanding of the problems associated with blood transfusion, such as increased surgical site infection (due to immunomodulation effect), increased length of hospital stay and increased cost. Based on the authors’ understanding of the available evidence, the routine use of a tourniquet during TKR is justified as good surgical practice.

Cite this article: Bone Joint J 2013;95-B, Supple A:133–4.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 893 - 899
1 Jul 2013
Diaz-Ledezma C Novack T Marin-Peña O Parvizi J

Orthopaedic surgeons have accepted various radiological signs to be representative of acetabular retroversion, which is the main characteristic of focal over-coverage in patients with femoroacetabular impingement (FAI). Using a validated method for radiological analysis, we assessed the relevance of these signs to predict intra-articular lesions in 93 patients undergoing surgery for FAI. A logistic regression model to predict chondral damage showed that an acetabular retroversion index (ARI) > 20%, a derivative of the well-known cross-over sign, was an independent predictor (p = 0.036). However, ARI was less significant than the Tönnis classification (p = 0.019) and age (p = 0.031) in the same model. ARI was unable to discriminate between grades of chondral lesions, while the type of cam lesion (p = 0.004) and age (p = 0.047) were able to. Other widely recognised signs of acetabular retroversion, such as the ischial spine sign, the posterior wall sign or the cross-over sign were irrelevant according to our analysis. Regardless of its secondary predictive role, an ARI > 20% appears to be the most clinically relevant radiological sign of acetabular retroversion in symptomatic patients with FAI.

Cite this article: Bone Joint J 2013;95-B:893–9.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 22 - 22
1 May 2013
Parvizi J
Full Access

Direct anterior approach (DAA) using the Hueter interval for total hip replacement (THA) provides an inter-nervous and inter-muscular access to the hip joint. Although it is technically demanding, the learning curve has been shown to be around 40 cases and 6 months in a high-volume joint surgeon's practice. A level-one study has demonstrated that DAA provides equal or better results and an equivalent rate of complications when compared to the highly utilized direct lateral approach. Using the available evidence to perform a multi-criteria decision analysis we demonstrated that DAA can be the most efficient approach to perform THA. From our standpoint, there is no reason to speculate a surgical approach with such advantages will be abandoned in the future. The DAA is here to stay, and may become the gold standard for THA.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 102 - 102
1 May 2013
Parvizi J
Full Access

Total knee arthroplasty is an operation that can be performed with or without the use of tourniquet. Two systematic reviews and meta-analyses of the available literature have demonstrated that the use of tourniquet leads to a reduction in blood loss and also shortens the operative time. The opponents for use of tourniquet cite development of complications such as skin bruising, neurovascular injury, and metabolic disturbances as a deterrent for the use of tourniquet. Although the latter may be true for some patients such as those with previous vascular grafts, there is little evidence that routine use of tourniquet during TKA results in any of the above complications. The use of tourniquet on the other hand provides a bloodless field that allows the surgeon to perform the procedure with expediency and optimised visualisation. Blood conservation has gained extreme importance in recent years because of increased understanding of problems associated with blood transfusion such as increased surgical site infection (due to immunomodulation effect), increased length of hospital stay, increased cost and so on. Based on our understanding of the available evidence, we believe that routine use of tourniquet during TKA is justified and a good surgical practice.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 280 - 280
1 Mar 2013
Nevelos J Boucher F Parvizi J Nessler JP Kolisek FR
Full Access

A novel cementless tapered wedge femoral hip implant has been designed at a reduced length and with a geometry optimized to better fit a wide array of bone types (Accolade II, Stryker, Mahwah, USA). In this study, finite element analysis (FEA) is used to compare the initial stability of the new proposed hip stem to predicate tapered wedge stem designs. A fit analysis was also conducted. The novel stem was compared to a predicate standard tapered stem and a shortened version of that same predicate stem.

Methods

The novel shortened tapered wedge stem geometry was designed based on a morphological study of 556 CT scans. We then selected 10 discrete femoral geometries of interest from the CT database, including champagne fluted and stove pipe femurs. The novel and the predicate stems were virtually implanted in the bones in ABAQUS CAE. A total of thirty FEA models were meshed with 4 nodes linear tetrahedral elements. Bone/implant interface properties was simulated with contact surface and a friction coefficient of 0.35. Initial stability of each stem/bone assembly was calculated using stair-climbing loading conditions. The overall initial stability of the HA coated surface was evaluated by comparing the mean rotational, vertical, gap-opening and total micromotion at the proximal bone/implant interface of the novel and predicate stem designs.

To characterize the fit of the stem designs we analyzed the ratio of a distal (60 mm below lesser trochanter) and a proximal (10 mm above lesser trochanter) cross section. A constant implantation height of 20 mm above the lesser trochanter was used. The fit of the stems was classified as Type 1 (proximal and distal engagement), Type 2 (proximal engagement only) and Type 3 (distal engagement only).

Results

The mean % micromotion of the HA coated surface greater than 50 mm was lowest at 40.2% (SD 11.5%) for the novel tapered wedge stem compared to the clinically successful predicate stem design (Accolade TMAZ, Stryker, Mahwah, USA) at 44.9% (SD 13.2%) and its shortened version at 48.5% (SD 9.0%) as shown in Figure 1. Improved initial stability of the new stem was also confirmed for rotational, vertical and gap-opening micromotion. However, there was no statistically significant difference.

The novel tapered stem design showed a well balanced proximal to distal ratio throughout the complete size range. The novel tapered stem design showed a reduced percentage of distal engagements (2.8%) compared to the predicate standard stem (17.2%). In the 40 to 60 year old male group the distal engagement for the standard stem increases (28.2%), whereas the distal engagements for the novel stem remains unchanged (1.3%).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 232 - 232
1 Mar 2013
Kurtz S MacDonald D Kocagoz S Tohfafarosh M Parvizi J Klein GR Lee G Marshall A Mont M Kraay M Stulberg B Rimnac C
Full Access

Introduction

Sequentially annealed highly crosslinked polyethylenes (HXLPEs) were introduced in total knee replacement (TKR) starting in 2005 to reduce wear and particle-induced osteolysis. Few studies have reported on the clinical performance of HXLPE knees. In this study, we hypothesized that due to the reduced free radicals, sequentially annealed HXLPE would have lower oxidation levels than gamma inert-sterilized controls.

Methods

145 tibial components were retrieved at consecutive revision surgeries at 7 different surgical centers. 74 components were identified as sequentially annealed HXLPE (X3, Stryker) while the remainder (n = 71) were conventional gamma inert sterilized polyethylene. The sterilization method was confirmed by tracing the lot numbers by the manufacturer. The conventional inserts were implanted for 1.7 years (Range: 0.0–9.3 years), while the X3 components were implanted 1.1 years (Range: 0.0–4.5 years). Surface damage was assessed using the Hood method. Oxidation analysis was performed in accordance with ASTM 2102 following submersion in boiling heptane for 6 hours to remove absorbed lipids. 30 of the conventional and 29 of the HXLPE inserts were available for oxidation analysis.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 108 - 108
1 Mar 2013
Higgs G Kurtz S Hanzlik J MacDonald D Kane WM Day J Klein GR Parvizi J Mont M Kraay M Martell J Gilbert J Rimnac C
Full Access

Introduction

Wear debris generation in metal-on-metal (MOM) total hip arthroplasty (THA) has emerged as a compelling issue. In the UK, clinically significant fretting corrosion was reported at head-taper junctions of MOM hip prostheses from a single manufacturer (Langton 2011). This study characterizes the prevalence of fretting and corrosion at various modular interfaces in retrieved MOM THA systems used in the United States.

Methods and Materials

106 MOM bearing systems were collected between 2003 and 2012 in an NIH-supported, multi-institutional retrieval program. From this collection, 88 modular MOM THA devices were identified, yielding 76 heads and 31 stems (22 modular necks) of 7 different bearing designs (5 manufacturers) for analysis. 10 modular CoCr acetabular liners and 5 corresponding acetabular shells were also examined. Mean age at implantation was 58 years (range, 30–85 years) and implantation time averaged 2.2 ± 1.8 years (range, 0–11.0 years). The predominant revision reason was loosening (n=52). Explants were cleaned and scored at the head taper, stem taper, proximal and distal neck tapers (for modular necks), liner, and shell interfaces in accordance with the semi-quantitative method of Goldberg et al. (2002).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 107 - 107
1 Mar 2013
Kurtz S MacDonald D Parvizi J Klein GR Lee G Marshall A Mont M Kraay M Stulberg B Malkani AL Rimnac C
Full Access

Introduction

The purpose of this multicenter study was to assess the oxidative stability, mechanical behavior, wear and reasons for revision of 2nd generation sequentially annealed HXLPE, X3, and compare it to 1st generation XLPE, Crossfire. We hypothesized that X3 would exhibit similar wear rates but lower oxidation than Crossfire.

Methods

182 hip liners were consecutively retrieved during revision surgeries at 7 surgical centers and continuously analyzed over the past 12 years in a prospective, multicenter study. 90 were highly crosslinked and annealed (Crossfire; Implanted 4.2±3.4 years, max: 11 years), and 92 were highly crosslinked and annealed in 3 sequential steps (X3; Implanted 1.2±1.5 years; max: 5 years). Oxidation was characterized in accordance with ASTM 2102 using transmission FTIR performed on thin sections (∼200μm) from the superior/inferior axis. Mechanical behavior was assessed via the small punch test (ASTM 2183).


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 4 - 9
1 Jan 2013
Goyal N Miller A Tripathi M Parvizi J

Staphylococcus aureus is one of the leading causes of surgical site infection (SSI). Over the past decade there has been an increase in methicillin-resistant S. aureus (MRSA). This is a subpopulation of the bacterium with unique resistance and virulence characteristics. Nasal colonisation with either S. aureus or MRSA has been demonstrated to be an important independent risk factor associated with the increasing incidence and severity of SSI after orthopaedic surgery. Furthermore, there is an economic burden related to SSI following orthopaedic surgery, with MRSA-associated SSI leading to longer hospital stays and increased hospital costs. Although there is some controversy about the effectiveness of screening and eradication programmes, the literature suggests that patients should be screened and MRSA-positive patients treated before surgical admission in order to reduce the risk of SSI.

Cite this article: Bone Joint J 2013;95-B:4–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 42 - 46
1 Nov 2012
Adeli B Parvizi J

Periprosthetic joint infection (PJI) is a devastating complication which can follow a total joint arthroplasty (TJA). Although rare, this ongoing threat undermines the success of TJA, a historically reputable procedure. It has haunted the orthopedic community for decades and several ongoing studies have provided insights and new approaches to effectively battle this multilayered problem.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 90 - 92
1 Nov 2012
Parvizi J Rasouli MR

In this paper, we will consider the current role of simultaneous-bilateral TKA. Based on available evidence, it is our opinion that simultaneous bilateral TKA carries a higher risk of morbidity and mortality and should be reserved for select few.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 206 - 206
1 Sep 2012
Cashman J MacKenzie J Parvizi J
Full Access

Background

The diagnosis of Periprosthetic Joint Infection (PJI) is a considerable challenge in total joint arthroplasty. The mainstay for diagnosis of PJI is a combination of serological markers, including C-reactive protein (CRP), along with joint aspirate for white cell count, differential and culture. The aim of this study was to examine the use of synovial fluid CRP in the diagnosis of PJI.

Material & Methods

Synovial fluid samples were collected prospectively from patients undergoing primary and revision knee arthroplasty. Samples were assessed for CRP, cell count and differential. Three groups were analyzed; those undergoing primary knee arthroplasty, aseptic knee arthroplasties and infected arthroplasties. Demographic data, along with associated medical co-morbidities, were collected,. Statistical analysis was performed. Synovial fluid CRP was correlated with serum CRP values. Sensitivity and specificity were calculated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 2 - 2
1 Sep 2012
Wuestemann T Bastian A Parvizi J Nessler J Kolisek F Nevelos J
Full Access

Introduction

The origins of the uncemented tapered wedge hip stem design currently offered by several orthopaedic device companies can be linked back to the cemented Straight Mueller type stem design first used in 1977. The design, a wedge shape with a taper angle of 6 degrees, maintains a single medial curvature for all sizes and increases laterally in the width to accommodate different size femurs. Although evolutionary improvements have been made over the years the basic body geometry of the stem has stayed mainly unchanged with excellent clinical survivorship. Over the past decade, the demographics of hip replacement have changed, with a large increase in younger male patients in the age range of 40 to 60 years. In this study the femoral fit of a novel tapered stem, designed to fit a wide array of patient types, is compared to a standard predicate tapered stem design.

Methods

A bone morphology study was performed on a patient population of 556 patients using three dimensional digital data from CT-scans. To characterize the fit of the stem designs we analyzed the ratio of a distal (60mm below lesser trochanter) and a proximal (10mm above lesser trochanter) cross section. The same measurements were taken with the standard tapered stem design and the novel tapered stem design, with a given constant implantation height of 20mm above the lesser trochanter. The fit of the stems was classified as Type 1, where there was both proximal and distal engagement, Type 2, proximal engagement only, Type 3, distal engagement only. The distal and proximal engagement, Type 1, was specified with a maximum engagement difference of 2mm proximal to distal.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 457 - 457
1 Nov 2011
Ketonis C Ayier A Barr S Adams CS Shapiro IM Hickok NJ Parvizi J
Full Access

Infection poses one of the greatest medical challenges, one further complicated by bacterial biofilm formation that renders the infection antibiotic insensitive. The goal of this investigation was to covalently link the antibiotic vancomycin (VAN) to a bone allograft so as to render the tissue inhospitable to bacterial colonization and the subsequent establishment of infection. We could achieve uniform tethering of the antibiotic to the allograft with minimal disruption of the underlying bone structure. The tethered VAN remained active against gram-positive organisms with no detectable S.aureus colonization. Additionally, the grafted VAN prevented biofilm formation, even in protected topographical niches. Attachment of the antibiotic to the allograft surface was robust-the stabilized VAN remained active for long time periods. Osteoblasts cultured on the VAN-allograft evidenced no changes in cellular phenotype. We opine that this new chimeric construct represents a superior transplantable substrate with a plethora of applications in medicine, dentistry and surgery.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 449 - 449
1 Nov 2011
Ketonis C Ayier A Shapiro I Parvizi J Hickok N
Full Access

Use of allograft bone has become standard for bridging defects unlikely to heal by simple fixation and routinely used in revision arthroplasties for implant stabilization. Unfortunately, this decellularized allograft provides an ideal surface for bacterial colonization, necessitating repeated surgeries, extensive debridement and lengthy antibiotic treatments. With up to 18% infection rate following allograft surgeries, a need for more effective means to prevent this process is evident. We describe a novel modification of native bone allografts that renders their surface bactericidal while increasing the effectiveness of systemic antibiotic treatments.

Allograft modification: Morselized human bone was washed extensively and sequentially coupled: 2X with Fmoc-aminoethoxyethoxyacetate (Fmoc-AEEA); deprotected with 20% piperidine in Dimethylformamide (DMF); and then coupled with vancomycin (VAN) for 12–16 hours. The VAN-bone was washed extensively with DMF and PBS for at least 1 day. VAN immuno-fluorescence: Control or VAN-bone was washed 5X with PBS, blocked with 10% FBS (1hr), incubated with rabbit anti-VAN IgG (4oC, 12h) followed by an Alexa-Fluor 488-coupled goat anti-rabbit IgG (1hr), and visualized by confocal laser microscopy. Antibiotic Activity. Equal dry weights of control and VANbone were sterilized with 70% ethanol, rinsed with PBS, and incubated with either Staphylococcus aureus (S. aureus) or Escherichia Coli (Ci=104 cfu) in TSB, 37oC, for 2, 5, 8 and 12 hrs. Antibiotic treatment: Clinical grade vancomycin was added to the solution with bacteria or following infection at a final concentration of 10μg/ml. Bacterial counts: Non-adherent bacteria were removed by washing and adherent bacteria suspended by sonication in 0.3% Tween-80 for 10mins followed by plating on 3M® Petrifilms. Bacterial visualization: Non-adherent bacteria were removed by washing extensively with PBS and adherent bacteria stained with the Live/Dead BacLight Kit (20mins, RT) to cause viable bacteria to fluoresce green. Samples were visualized by confocal microscopy.

In comparison to controls, VAN-bone consistently reduced the graft bacterial load by ~90% at all time points. After staining and visualization of adherent bacteria, biofilm formation was apparent on controls by 12 hrs and absent from VAN-bone. E.coli, a gramnegative organism that is not sensitive to VAN, readily colonized both control and VANbone, confirming retention of VAN specificity. We then evaluated VAN-bone activity in a system that modeled systemic antibiotic therapy and antibiotic prophylaxis. In the absence of solution antibiotics, VAN-bone exhibited a significant decrease in bacterial colonization as compared to controls. When 10 μg/ml VAN was added to the medium for the last 4 h (modeling systemic antibiotic therapy), colonization of control surfaces was reduced, while colonization of VAN-allograft was almost eliminated. When 10 μg/ml VAN was added concomitantly with S. aureus, VAN-bone colonization was undetectable, while colonization of control surfaces still occurred.

We have previously described an antibiotic-tethered allograft that resists bacterial colonization. In this abstract, we test this technology with an vitro model of bone implantation in the presence of solution antibiotics. In these models, solution antibiotics failed to prevent infection of control bone while completely clearing the bacteria on VAN-bone. Furthermore, VAN bone exhibited high activity against S. aureus, a gram positive organism, whereas it was ineffective against E. coli, a gram negative organism. The specificity of the tethered antibiotic supported the view that the antibacterial properties of the allograft were related to the tethered antibiotic and not to undefined aspects of the attachment chemistry. In terms of antibacterial activity, when challenged with 104 CFU S. aureus (with concentrations reaching > 107 CFU by 24 h), the antibiotic -modified allograft consistently decreased bacterial colonization by > 90%; S. aureus inocula < 102 CFU resulted in no detectable colonization of the VAN-allograft. Thus, development of these allografts may not only combat allograft colonization but increase the effectiveness of prophylactic antibiotics to ultimately result in a new therapy for allograft-associated infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1303 - 1307
1 Oct 2011
Jung KA Restrepo C Hellman M AbdelSalam H Morrison W Parvizi J

We performed a retrospective examination of the anteroposterior pelvic CT scout views of 419 randomly selected patients between April 2004 and August 2009 in order to determine the prevalence of cam-type femoroacetabular deformity in the asymptomatic population. The CT scans had all been undertaken for conditions unrelated to disorders of the hip. The frequency of cam-type femoroacetabular deformity was assessed by measuring the α-angle of each hip on the anteroposterior images. The α-angles were classified according to the Copenhagen Osteoarthritis Study. Among 215 male hips (108 patients) the mean α-angle was 59.12° (37.75° to 103.50°). Of these, a total of 30 hips (13.95%) were defined as pathological, 32 (14.88%) as borderline and 153 (71.16%) as normal. Among 540 female hips (272 patients) the mean α-angle was 45.47° (34.75° to 87.00°), with 30 hips (5.56%) defined as pathological, 33 (6.11%) as borderline and 477 (88.33%) as normal. It appears that the cam-type femoroacetabular deformity is not rare among the asymptomatic population. These anatomical abnormalities, as determined by an increased α-angle, appear to be twice as frequent in men as in women. Although an association between osteoarthritis and femoroacetabular impingement is believed to exist, a long-term epidemiological study is needed to determine the natural history of these anatomical abnormalities.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 262 - 262
1 Jul 2011
Resterpo C Parvizi J Sharkey PF Pour AE Haytmanek CT Roberts N Rothman RH
Full Access

Purpose: Recently an orthopedic manufacturer has introduced a gender specific knee design implying that there is a substantial anatomical difference between the genders. If such concept is true then TKA prosthesis implanted in the female population over the last decades, by definition, must have suboptimal outcome when compared to the male patients. The purpose of this study was to examine the functional outcome, the incidence of complications, and the need for revision between the two genders receiving the same knee design.

Method: The study selected a matched group of 150 men and 250 women undergoing TKA at our instituion. The patients were matched for age, BMI, pre-op diagnosis, comorbidities, race, mode of fixation, and the type of implant. Other demographic, surgical, and medical factors between the two genders were similar. Both pre-op and post-op functional scores were compared between the two groups. Pre-op and post-op radiographic images were assessed for implant fit.

Results: There was a significant improvement in functional outcome as measured by Knee Society score, WOMAC, and SF-36 for all patients. The improvement in functional outcome was not different between the two groups. The incidence of complications, reoperations, and need for revision between the two genders was also not significantly different.

Conclusion: Total knee arthroplasty continues to be an effective surgical procedure. Both genders appear to enjoy relief of pain and improvement of function equally. Based on this retrospective study the use of non-gender specific knee prosthesis did not seem to result in suboptimal outcome in female patients. There appears to be little merit in introduction of gender specific knee designs when previous non-gender specific prosthesis appeared to function well in both genders.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 251 - 251
1 Jul 2011
Parvizi J Bican O Bozic K Peters C
Full Access

Purpose: Hip arthroscopy has been used at an increasing frequency over the last few years. Majority of patients undergoing hip arthroscopy are young and active individuals who seek definitive therapy for a painful hip condition and wish to avoid undergoing a hip replacement. Although relatively successful, complications following hip arthroscopy occur. This multi-institutional study presents a worrisome and previously unrecognized complication of hip arthroscopy, namely chondrolysis that lead to accelerated development of end-stage arthritis.

Method: Using the computerized database in each institution, patients undergoing total hip arthroplasty between 1999–2008 who had received hip arthroscopy prior to arthroplasty were identified. 39 patients were identified to have undergone at least one hip arthroscopy on the affected hip prior to arthroplasty. There were 21 female and 18 male patients. The mean age of patients at the time of hip arthroscopy was 45.9 years. Data regarding demographics, comorbidities, preoperative diagnosis, number of previous procedures, and the details of the surgical procedure were compiled. Radiographs were evaluated.

Results: The median time from arthroscopy to arthroplasty was 14.8 months (range 2.2 months to 7 years). Fourteen patients (35%) underwent THA within 12 months of a previous hip arthroscopy and in nine of these patients the indication for hip arthroscopy was labral tear debridement. These patients despite having none to minimal arthritis at the time of arthroscopy developed accelerated arthritis within a year that necessitated hip replacement.

Conclusion: Hip arthroscopy can cause accelerated degenerative arthritis of the hip in some patients. We believe the subset of our patients who developed arthritis so early after hip arthroscopy may have suffered chondrolysis and/or chondral injury during the arthroscopy that resulted in progressive and aggressive arthritis of the hip within 12 months. Hip arthroscopy should be reserved for a select group of patients. All measures to minimize the possibility of chondrolysis and/or chondral injury should be exercised.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 250 - 250
1 Jul 2011
Parvizi J Pulido L Matar M Marchetto N Og B
Full Access

Purpose: Femoroacetabular impingement (FAI) is recognized as an etiological risk factor for hip arthritis. The potential for joint preserving surgical techniques that may delay the progression to early arthritis and retard the possibility of arthroplasty at a young age is promising. This study presents the outcome of surgical treatment of FAI through a less invasive technique performed through a modified Smith-Peterson approach without hip dislocation, or arthroscopy.

Method: Using an institutional database, a total of 72 patients (80 hips) with radiographic and clinical diagnosis of FAI who underwent direct anterior femoroacetabular osteoplasty (FAO) were identified. Preoperative and postoperative functional evaluation was performed on these patients. The operative findings were recorded in detail and evaluated with regard to outcome.

Results: Intraoperative diagnosis of labral tear and osteochondral lesions in the anterosuperior acetabulum was confirmed in all cases. The surgical approach provided adequate access to allow labral repair and osteoplasty of the femoral neck and the acetabulum, whenever needed. There were no intraoperative complications. All patients experienced a significant improvement in function as measured by modified Harris hip and SUSHI scores. Majority (85%) of the patients were satisfied with the outcome of the surgery. In addition, Health Survey SF-36 showed most patients felt their health had improved significantly. The predictors of poor outcome were previous hip scope, lack of labrum for repair, large chondral lesions, and workman’s compensation status.

Conclusion: This study presents the early results of a less invasive surgical treatment for femoroacetabular impingement. This ongoing study shows that the described technique seems to be a viable approach for treatment of this painful condition in the young.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 275 - 275
1 Jul 2011
Ghanem E Pawasarat I Restrepo C Azzam K May L Austin MS Parvizi J
Full Access

Purpose: The purpose of our study is to compare hips to knees in regards to the cost per increase in function, to determine the relationship of economic investment to improved quality of life.

Method: During the year 2005, a total of 23 TKA and 41 THA revisions were performed for aseptic mechanical failure. Patients were enrolled prospectively and quality of life questionnaires including the SF-36, WOMAC, Harris Hip Score (HHS), and Knee Society Score (KSS) were collected prior to and following their procedure at two year follow-up. The total cost of the procedure including the hospital, implant, and surgeon fee were implemented in a cost effectiveness model to calculate the mean cost per SF-36, WOMAC, and HHS or KSS point gained. Demographical variables and co-morbidities were collected to determine risk factors for low cost-effectiveness.

Results: The majority of patients had significant improvement in SF-36, WOMAC, HHS and KSS scales. Patients with THA revisions experience a cost per point increase for HHS of $3,000, and $500 per point SF-36 compared to knee patients who experienced a cost per point increase for KSS of $2,000, and $2,800 per point SF-36. The WOMAC exhibited similar cost effectiveness in the subscales of pain, stiffness and functioning.

Conclusion: There are few studies that have compared the cost effectiveness of total joint arthroplasty revision procedures. Given the increasing cost of health care expenditures, prioritization of funding for the different health practices will become necessary. This study demonstrates that revision THA and TKA are relatively cost effective procedures compared to other non-orthopaedic interventions.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 156 - 157
1 May 2011
Wuestemann T Bastian A Schmidt W Cedermark C Streicher R Parvizi J Rothman R
Full Access

Introduction: Clinical experience has shown that addressing variations in bone morphology is important in the development of successful hip implant designs. Numerous studies of femoral bone morphology have been published utilizing various techniques. This study has developed a method which consistently measures large quantities of 3-dimensional digital femura geometry segmented from computed tomography (CT) scans and can accurately make anatomical measurements from these images

Methods: CT images of left femora on five hundred fifty six left femura (57% male, 43% female), consisting of 69% Caucasian, 16% Asian and 14% unknown were analyzed. The average age was 66 years, ranging from 40 to 93 years. Segmentation of the outer cortical, inner cortical, and marrow boundaries were consistently performed over all CT scans. The positions identified on the reference bone are transformed to the equivalent position on the clinical bone images, from which the dimensional data is extracted and stored. The mediolateral width (MLW), medial offset (MO) and lateral offset (LO) were measured in 10mm increments, ranging from 20mm above the lesser trochanter (LT) to 130mm below the lesser trochanter. The canal flare index was defined as a ratio of the mediolateral width at a section 20mm above the lesser trochanter to the mediolateral width at the isthmus level.

Results: The mean mediolateral width at 20mm above the lesser trochanter was 47.0 ± 4.5 (35.1–61.8; n=556). Noble reported 45.4 ± 5.3 (31.0–60.0; n=200), Husmann reported in a neck oriented study 46.3 ± 6.9 (27.6–63.6; n=310) and Laine reported 47.1 ± 4.9 (n=50). The mean medial offset at a section 20mm above the lesser trochanter was 25.1 ± 2.9 (16.7–33.4). In the study by Husmann, a mean of 25.0 ± 5.2 (9.4–45.5) was reported. The mean canal flare index was 4.49 ±.8. Noble reported a mean canal flare index of 3.80 ±.074, Husmann 3.81 ±.83 and Laine 4.3 ±.93.

Discussion: In general, the study showed minor differences to published data of proximal bone morphology. However, this more powerful study has shown that there is a higher mean canal flare index than determined by Noble and a similar mean canal flare index as determined by Laine. As reported by Laine, the canal flare index varies significantly with the placement of measurements in the canal. In this study the measurements were performed in a plane oriented by the femoral neck as a hip stem would be placed. The CFI over the isthmus width showed a greater correlation than previously shown by Noble. The novel software tool allows for anatomical measurements that can be applied to an unlimited population size enabling further applications and studies.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 298 - 298
1 May 2009
Jaberi M Eslampour A Haytmanek C Parvizi J Ghanem E Purtill J
Full Access

Persistent wound drainage after total joint arthroplasty (TJA) has been associated with a higher incidence of superficial and deep periprosthetic infection but the predictors for prolonged drainage and its outcome have not been thoroughly studied.

A consecutive series of 7,153 TJA cases performed between 2000 and 2006 at our institute, were recruited into this study. There were 301 cases (4.2%) of persistent wound drainage, defined as discharge from the wound for > 48 hours. The cases were matched in a 2:1 ratio for type of surgery, joint replaced, and date of surgery.

This study identified higher BMI (p< 0.005), malnutrition as defined by serum albumin< 3.4g/dl (p< 0.04), longer operative time (p< 0.01), and higher medical comorbidities, in particular diabetes (p< 0.001) as important risk factors for persistent wound drainage. In addition, patients in the drainage group were more likely to have a peak INR of > 1.5 (p< 0.001) during their hospital stay. Patients with wound drainage had a significantly lower hemoglobin postoperatively (p< 0.01) that necessitated greater number of postoperative allogenic transfusions (p=0.004). The hospital length of stay for the drainage group was also significantly higher (p< 0.005). One of the major risk factors for development of deep infection was prolonged drainage (> 7 days). In the deep hematoma and periprosthetic subgroups, the mean of delay in treatment was 6 days in those with retention of the prosthesis and successful outcome, and 9.5 days for those with failure of incision and drainage leading to resection arthroplasty (p= 0.03).

72% of the patient were successfully treated by oral or intravenous antibiotics. 27% required at least one re-operation for deep hematoma and 13% developed deep periprosthetic infection, resulting in 6% rate of resection arthroplasty. 1.5% of those with drainage remained in girdlestone status.

This study suggests early surgery for persistent drainage and avoidance of aggressive anticoagulation.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 308 - 308
1 May 2009
Ghanem E Antoci V Sharkey P Barrack R Spangehl M Parvizi J
Full Access

Serological tests including erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) are frequently used in the preoperative workup to screen for periprosthetic infection (PPI) in total hip arthroplasty (THA). The cut-off points reported in the literature are arbitrarily chosen by investigators. Similarly, the values used in laboratories to distinguish elevated results vary from one institute to another. Therefore, we intended to define the appropriate cut-off points of ESR and CRP that can be used to differentiate infection from aseptic failure of THA.

A review of our joint registry database revealed that 515 THA revisions (131 infected cases) were performed during 2000–2005. Intraoperative samples for culture were taken in all cases. The criteria used for diagnosis of infection were a positive intraoperative culture on solid media, presence of an abscess or sinus tract that communicated with the joint, positive preoperative aspiration culture, and/or elevated fluid cell count and neutrophil differential of the aspirated fluid. Non-infected patients with confounding factors that can elevate ESR and CRP including collagen vascular disease, inflammatory arthropathy, malignancy, and urinary tract infection were excluded. Receiver operator curves were used to determine the ideal cut-off point for both ESR and CRP.

The mean value of ESR in the infected group (77mm/ hr) was significantly higher compared to that of the non-infected cohort (29mm/hr) (p=0.0001). Similarly, infected patients presented with a greater mean CRP (9.8 mg/dl) than their non-infected cohort (1.48 mg/ dl) (p=0.0001). The infection threshold for ESR was 45mm/hr with a sensitivity of 85% and specificity of 79%, while the optimal cut-off value for CRP was defined as 1.6 mg/dl which yielded a sensitivity of 86% and specificity of 83%.

The optimal threshold values we determined are higher than the arbitrarily chosen values cited in the literature for ESR (30mm/hr) and CRP (1mg/dl). Although it has been previously reported that the sensitivity and specificity of CRP are far greater than that of ESR, we found that the two tests have comparable diagnostic value.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 308 - 308
1 May 2009
Elie G Pulido L Restrepo C Houssock C Parvizi J
Full Access

Periprosthetic infection (PPI) remains the most dreaded and difficult complication of total joint arthroplasty. Although there is no definite diagnostic test for PPI, synovial leukocyte count and neutrophil percentage have been reported to have high sensitivity and specificity. However, leukocytes and neutrophils introduced into the joint during a traumatic aspiration can skew results and undermine the predictive value of this diagnostic test. This study intends to determine the diagnostic value of implementing a corrective formula frequently used in traumatic spinal taps to adjust for serum leukocytes introduced into the joint fluid during a bloody tap.

We conducted a review of all TKA aspirations of infected and non-infected patients performed at our institute from 2000 to 2005.

The following inclusion criteria were used:

(a) a red cell count (RBC) was performed on the aspirate, and

(b) a blood white cell count with differential was done within one week of aspiration.

Patients with inflammatory arthropathy or those who underwent reimplantation after PPI were excluded. Strict criteria for diagnosis of PPI were used. We previously determined at our institute the cut-off values for fluid leukocyte count (> 1760 cells/μl) and neutrophil percentage (> 73%).

The adjusted fluid leukocyte counts were calculated using the following formula:

Wadjusted = WBCobserved – [(WBCblood * RBC-fluid/RBCblood)] predicted.

A similar formula was implemented to calculate the adjusted absolute neutrophil counts.

Our cohort included 73 infected and 32 aseptic total knee arthroplasties that fulfilled the above criteria. After correcting for introduced red blood cells, cell counts of 3 infected patients dropped below the cut-off value, while the remaining 70 maintained a high cell count. However, the 3 infected patients had initial cell counts below our reported cut-offs. Of the 32 non-infected patients, 10 patients had false positive cell counts due to the presence of extremely high numbers of blood RBC. Five of the 10 false positive aspirates successfully corrected to levels below the thresholds used to diagnose infection. The aspirates that corrected had a greater number of introduced RBCs, an initial higher cell count, and 20 times more fluid WBC deducted from the initial cell count.

The corrective formula can safely adjust for RBC found in a traumatic tap and detect false positive results among non-infected TKA without compromising the diagnosis of infection. Adjusted aspirates of non-infected TKA can be expected to decrease below zero due to one of the following: adherence of the introduced systemic WBC to the joint synovium, greater rate of lysis of the introduced systemic WBC compared to the systemic RBC, laboratory errors in performing fluid cell counts.