Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 84 - 84
1 Dec 2016
Nyland M Lanting B Somerville L Vasarhelyi E Naudie D McAuley J McCalden R MacDonald S Howard J
Full Access

Infection following total hip arthroplasty (THA) represents a devastating complication and is one of the main causes for revision surgery. This complication may be treated by irrigation and debridement with head and polyethylene exchange (IDHPE) or a two-stage revision (2SR). Previous studies have reported on the eradication success rates but few have reported patient outcome scores. The purpose of this study was to report patient outcome scores for both IDHPE and 2SR and compare these to a non-infected matched cohort. We hypothesised that both cohorts would have worse outcomes than the control group, and that those who failed an initial IDHPE and required a 2SR would have a worse outcome than those treated initially with a 2SR.

A retrospective review identified 137 patients from our institutional arthroplasty database who had an infected primary THA between 1986–2013. We excluded patients with less than one-year follow-up. Mean follow-up was 60 months (12–187 months). A control cohort was identified and matched according to age and Charlton Comorbidity Index (CCI). Harris Hip Scores, Short Form 12 and WOMAC scores were compared between our control group and our infected cohort.

Sixty-eight patients were treated with a 2SR and 69 patients were treated with an IDHPE. There was a 59% success rate in eradicating the infection with an IDHPE. All of the 28 patients who failed an IDHPE later went on to a 2SR. Outcome scores for the 2SR cohort were significantly worse than the non-infected controls (p0.05). There was no difference in outcome scores when comparing our 2SR cohort to our failed IDHPE (p>0.05).

Previous studies have focused on eradication rates. However, it is important to consider patient outcome scores when deciding the best treatment. Infected patients treated with a successful IDHPE had similar outcomes to non-infected patients. Patients that failed IDHPE and went onto 2SR had similar outcomes to those that had a 2SR alone. IDHPE should still be considered in the treatment algorithm of infected THA.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 59 - 59
1 Dec 2016
Sisko Z Teeter M Lanting B Howard J McCalden R Naudie D MacDonald S Vasarhelyi E
Full Access

Previous retrieval studies demonstrate increased tibial baseplate roughness leads to higher polyethylene backside wear in total knee arthroplasty (TKA). Micromotion between the polyethylene backside and tibial baseplate is affected by the locking mechanism design and can further increase backside wear. The purpose of this study was to examine modern locking mechanisms, in the setting of both roughened and polished tibial baseplates, on backside tibial polyethylene wear.

Five TKA models were selected, all with different tibial baseplate and/or locking mechanism designs. Six retrieval tibial polyethylenes from each TKA model were matched based on time in vivo (TIV), age at TKA revision, BMI, gender, number of times revised, and revision reason. Two observers scored each polyethylene backside according to a visual damage score and individual damage modes. Primary outcomes were mean damage score and individual damage modes. Demographics were compared by one-way ANOVA. Damage scores and modes were analysed by the Kruskal-Wallis test and Dunn's multiple comparisons test.

There were no differences among the groups based on TIV (p=0.962), age (p=0.651), BMI (p=0.951), gender, revision number, or reason for revision. There was a significant difference across groups for mean total damage score (p=0.029). The polished tibial design with a partial peripheral capture locking mechanism and anterior constraint demonstrated a significantly lower score compared to one of the roughened tibial designs with a complete peripheral-rim locking mechanism (13.0 vs. 22.1, p=0.018). Otherwise, mean total damage scores were not significant between groups. As far as modes of wear, there were identifiable differences among the groups based on abrasions (p=0.005). The polished design with a tongue-in-groove locking mechanism demonstrated a significantly higher score compared to both groups with roughened tibial baseplates (5.83 vs. 0.83, p=0.024 and 5.83 vs. 0.92, p=0.033). Only the two designs with roughened tibial baseplates demonstrated dimpling (5.67 and 8.67) which was significant when compared against all other groups (p0.99). No other significant differences were identified when examining burnishing, cold flow, scratching, or pitting. No polyethylene components exhibited embedded debris or delamination.

Total damage scores were similar between all groups except when comparing one of the polished TKA design to one of the roughened designs. The other TKA model with a roughened tibial baseplate had similar damage scores to the polished designs, likely due to its updated locking mechanism. Dimpling wear patterns were specific for roughened tibial baseplates while abrasive wear patterns were identified in the design with a tongue-in-groove locking mechanism. Our study showed even in the setting of a roughened tibial baseplate, modern locking mechanisms decrease backside wear similar to that of other current generation TKA designs.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 59 - 59
1 Nov 2016
Goyal P Yuan X Teeter M McCalden R MacDonald S Vasarhelyi E McAuley J Naudie D Lanting B Howard J
Full Access

Studies that have previously examined the relationship between inclination angle and polyethylene wear have shown increased wear of conventional polyethylene with high inclination angles. To date, there have been no long term in vivo studies examining the correlation between cup position and polyethylene wear with highly crosslinked polyethylene.

An institutional arthroplasty database was used to identify patients who had metal-on-highly crosslinked polyethylene primary total hip arthroplasty (THA) using the same component design with a minimum follow up of 10 years ago. A modified RSA examination setup was utilised, recreating standard anteroposterior (AP) and cross-table lateral exams in a single biplane RSA acquisition. Three dimensional head penetration was measured using the centre index method. The same radiographs were used to measure inclination angle and anteversion. Spearman correlation was used to show an association between the parameters of acetabular position and wear rate.

A total of 43 hips were included for analysis in this study. Average follow-up was 12.3 ± 1.2 years. The average linear wear rate was calculated to be 0.066 ± 0.066 mm/year. Inclination angle was not correlated with polyethylene wear rate (p=0.82). Anteversion was also not correlated with polyethylene wear rate (p=0.11). There was no statistical difference between wear rates of hips within Lewinnek's “safe zone” and those outside this “safe zone” (p=0.11). Males had a higher wear rate of 0.094 ± 0.089 mm/year compared to females with a wear rate of 0.046 ± 0.032 mm/year (p=0.045).

At long term follow up of greater than 10 years, highly cross linked polyethylene has very low wear rates. This excellent tribology is independent of acetabular position, but gender did impact wear rates. Due to the low wear rates, follow-up of even longer term is suggested to examine variables affecting wear.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 87 - 87
1 Nov 2016
Matz J Morden D Teeter M McCalden R MacDonald S Vasarhelyi E McAuley J Naudie D Howard J Lanting B
Full Access

Complications involving the patellofemoral joint are a source of anterior knee pain, instability, and dysfunction following total knee arthroplasty. “Overstuffing” the patello-femoral joint refers to an increase in the thickness of the patellofemoral joint after a total knee replacement compared to the preoperative thickness. While biomechanical studies have indicated that overstuffing the patellofemoral joint may lead to adverse clinical outcomes, limited clinical evidence exists to support this notion. The purpose of this study is to evaluate the effect of changing the thickness of the patellafemoral joint on functional outcomes following total knee arthroplasty.

Our institutional arthroplasty database was used to identify 1347 patients who underwent a primary total knee arthroplasty between 2006 and 2012 with the same component design. Standard preoperative and postoperative anteroposterior, lateral, and skyline radiographs were collected and measured for patello-femoral overstuffing. These measurements included anterior patellar displacement, anterior femoral offset, and anteroposterior femoral size. These measurements were correlated with patient outcome data using WOMAC, KSS scores, and postoperative range of motion. Multiple linear regression analysis was used to assess the association between stuffing and functional outcomes.

A total of 1031 patients who underwent total knee arthroplasty were included. Increased anterior patellar displacement, a measure of patellofemoral joint thickness, was associated with decreased WOMAC scores (p=0.02). Anterior femoral offset (p=0.210) and anteroposterior femoral size (p=0.091) were not significantly associated with patient functional outcomes. Postoperative range of motion (ROM) was not associated with patellofemoral stuffing (p=0.190).

The current study demonstrated that functional outcomes are adversely affected by patellofemoral overstuffing. Based on these results, caution is encouraged against increasing the thickness of the patellofemoral joint, particularly on the patellar side of the joint.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 95 - 95
1 Nov 2016
Howard J Vijayashankar R Sogbein O Ganapathy S Johnston D Bryant D Lanting B Vasarhelyi E MacDonald S
Full Access

Pain immediately following total knee arthroplasty (TKA) is often severe and can inhibit patients' rehabilitation. Recently, adductor canal blocks have been shown to provide adequate analgesia and spare quadriceps muscle strength in the early postoperative period. We devised a single injection motor sparing knee block (MSB) by targeting the adductor canal and lateral femoral cutaneous nerve with a posterior knee infiltration under ultrasound. Our primary objective was to evaluate the analgesia duration of the MSB in comparison to a standard periarticular infiltration (PAI) analgesia using patients' first rescue analgesia as the end point. Secondary outcomes measured were quadriceps muscle strength and length of stay.

We randomised 82 patients scheduled for elective TKA to receive either the preoperative MSB (0.5% ropivacaine, 2.5ug/ml epinephrine, 10mg morphine, and 30mg ketorolac) or intraoperative periarticular infiltration (0.3% ropivacaine, 2.5ug/ml epinephrine, 10mg morphine, and 30mg ketorolac). Duration of analgesia, postoperative quadriceps power, and length of stay were evaluated postoperatively.

Analgesic duration was found to be significantly different between groups. The MSB had a mean duration of 18.06 ± 1.68 hours while the PAI group had a mean duration of 9.25 ± 1.68 hours for a mean difference of 8.8 hours (95% CI 3.98 to 13.62), p<0.01. There were no significant differences between groups in quadriceps muscle strength power at 20 minutes (p=0.91) or 6 hours (p=0.66) after block administration. Length of stay was also not significantly different between the groups (p=0.29).

Motor sparing blocks provide longer analgesia than patients receiving periarticular infiltration while not significantly reducing quadriceps muscle strength or increasing length of hospital stay.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 57 - 57
1 Nov 2016
Lanting B Tan S Lau A Teeter M Del Balso C McCalden R MacDonald S Vasarhelyi E McAuley J Naudie D Howard J
Full Access

Trunnionosis in modular hip arthroplasty has recently been recognised to be clinically important. Gaining an understanding of how the material interface at the head-trunnion affects the tribology at the modular junctions has current clinical implications as well as an implication on future implant selection and material choice. This matched-cohort study aims to compare tribocorrosion between ceramic and cobalt-chromium trunnions and to investigate other factors that contribute to the difference in tribocorrosion if present.

All hip prostheses retrieved between 1999 and 2015 at one centre were reviewed. Fifty two ceramic heads were retrieved, and these were matched to a cobalt-chromium cohort according to taper design, head size, neck length and implantation time in that order. The two cohorts were similar in male:female ratio (p=0.32) and body mass index (p=0.15) though the ceramic group was younger than the cobalt-chromium group (56.6 (+/−)13.5 years for ceramic group vs 66.3 (+/−14.4) years for cobalt-chromium group; p=0.001). There was no significant difference in the reasons for revision between the two groups (p=0.42). The femoral head trunnions were examined by two independent observers using a previously published 4-point scoring technique. The trunnions were divided into three zones: apex, middle and base. The observers were blinded to clinical and manufacturing data where possible.

Ceramic head trunnions demonstrated a lower median fretting and corrosion score at the base zone (p<0.001), middle zone (p<0.001) and in the combined score (p<0.001). In a subgroup analysis by head size, ceramic heads had a lower fretting and corrosion score at 28mm head diameter (p<0.001). Within the ceramic group, taper design had a significant effect on fretting and corrosion in the apex zone (p=0.04). Taper design also had a similar effect in the cobalt-chromium group in the apex zone (p=0.03). For the ceramic trunnions, the largest effect was contributed by the difference between the 11/13 taper and the 12/14 taper. For the cobalt-chromium trunnions, the largest effect was contributed by the difference between the 5 degree 38′ 37″ taper and type 1 taper.

Ceramic head trunnions showed a significantly lower fretting and corrosion score as compared to cobalt-chromium trunnions. Ceramic heads had a lower score than cobalt-chromium heads at 28mm head diameter. Taper design had an effect on fretting and corrosion within each cohort.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 62 - 62
1 Nov 2016
MacLean C Vasarhelyi E Lanting B Naudie D Somerville L McCalden R McAuley J MacDonald S Howard J Yuan X Teeter M
Full Access

The advent of highly cross-linked polyethylene has resulted in improved wear rates and reduced osteolysis with at least intermediate follow-up when compared to conventional polyethylene. However, the role of alternative femoral head bearing materials in decreasing wear is less clear. The purpose of this study was to determine in-vivo polyethylene wear rates across ceramic, Oxinium, and cobalt chrome femoral head articulations.

A review of our institutional database was performed to identify patients who underwent a total hip arthroplasty using either ceramic or oxidised zirconium (Oxinium) femoral head components on highly cross-linked polyethylene between 2008 and 2011. These patients were then matched on implant type, age, sex and BMI with patients who had a cobalt chrome bearing implant during the same time period. RSA analysis was performed using the centre index method to measure femoral head penetration (polyethylene wear). Secondary quality of life outcomes were collected using WOMAC and HHS Scores. Paired analyses were performed to detect differences in wear rate (mm/year) between the cobalt chrome cohorts and their matched ceramic and Oxinium cohorts. Additional independent group comparisons were performed by analysis of variance with the control groups collapsed to determine wear rate differences between all three cohorts.

A total of 68 patients underwent RSA analysis. Fifteen patients with a ceramic femoral head component and 14 patients with an Oxinium femoral head component along with the same number of matched patients with cobalt chrome femoral head component were included in the analysis. The time in vivo for the Oxinium (5.17 +/− 0.96 years), Oxinium matched cohort (5.13 +/− 0.72 years), ceramic (5.15 +/− 0.76 years) and ceramic matched cohort (5.36 +/− 0.63 years) were comparable. The demographics of all bearing surface cohorts were similar. The paired comparison between the Oxinium and cobalt chrome cohorts (0.33 vs. 0.29 mm/year, p=0.284) and ceramic vs cobalt chrome cohorts (0.26 vs. 0.20 mm/year, p=0.137) did not demonstrate a significant difference in wear rate. The independent groups analysis revealed a significantly higher wear rate of Oxinium (0.33 mm/year) compared to cobalt chrome (0.24 mm/year) (p = 0. 038). There were no differences in HHS and WOMAC scores between the Oxinium and cobalt chrome cohorts (HHS: p = 0.71, WOMAC: p=0.08) or the ceramic and cobalt chrome cohorts (HHS: p=0.15, WOMAC: p=023).

This study presents evidence of a greater wear rate (mm/year) of the Oxinium femoral head component compared to a cobalt chrome femoral head component. This difference was not demonstrated in the ceramic femoral head component. Despite this difference, there were no clinical differences as measured by the HHS and WOMAC. Future research should focus on factors that may contribute to the higher wear rate seen in the Oxinium cohort.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 58 - 58
1 Nov 2016
Neely S Berta D Ralley F Lanting B Vasarhelyi E McAuley J McCalden R MacDonald S Naudie D Howard J
Full Access

Total joint arthroplasty is commonly associated with post-operative anemia. Blood conservation programs have been developed to optimise patients prior to surgery. Epoetin Alfa (Eprex) or intravenous (IV) iron transfusions are two modalities that can be used pre-operatively to optimise hemoglobin and ferritin levels. There are, however, potential complications and increased costs associated with their use. Oral iron is a less costly option for those undergoing surgery but requires more time to take effect. There are no studies to date that examine the effects of an early screening program utilising oral iron supplementation prior to total joint arthroplasty. The purpose of this study is to evaluate the effect of implementing early pre-operative oral iron supplementation on patients prior total joint arthroplasty.

A retrospective review of patients undergoing total joint arthroplasty was performed using our institution clinical informatics database. We identified all patients seen in pre-admission clinic (PAC) between Jan 1, 2009 and March 31, 2010 representing our control group. We then identified all patients seen in PAC between October 1, 2012 and December 31, 2013. Patients in this cohort received screening blood work when booked for surgery, and oral iron supplementation was given to patients with hemoglobin of less than 135g/L or ferritin less than 100ug/L, thus representing our treatment group. Patients undergoing revision, uni-compartment knee arthroplasty and bilateral arthroplasties were excluded from the study. Pearson Chi-Square tests were used to calculate significance between groups with main outcomes including pre-admission hemoglobin, and pre-operative requirements for Eprex or IV iron.

In our control group, we identified 354 patients (25.6%) with hemoglobin less than 130 g/L at time of pre-admission clinic. In our treatment group, this number dropped significantly to only 16.4% of patients (p<0.005).

Implementation of an early screening program using oral iron supplementation resulted in a decrease in the number of patients with hemoglobin lower than 130 g/L at the time of pre-admission clinic. There was also a significant decrease in the use of Eprex and IV iron pre-operatively in the patients in the early screening program. These results encourage the use of early oral iron supplementation for patients with hemoglobin less than 135 g/L or ferritin less than 100ug/L in order to optimise patients prior to total joint arthroplasty.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 63 - 63
1 Nov 2016
Akindolire J Marsh J Howard J Lanting B Somerville L Vasarhelyi E
Full Access

Total hip arthroplasty (THA) has become one of the most commonly performed elective procedures. Today, there are nearly 50 000 annual hospitalisations for hip replacement surgery in Canada. This number is projected to increase significantly with the aging population. Periprosthetic joint infection (PJI) is the 3rd leading cause of failure following THA and is reported to occur at an incidence of 1–3%. A two-stage re-vision THA is the current gold standard treatment and this has a tremendous economic impact on the healthcare system. The purpose of this study is to create an accurate cost estimate of two-stage revision THA and, in turn, evaluate the economic burden of PJI as it compares to primary THA in a Canadian healthcare context.

We conducted a retrospective review of primary THA cases and two-stage revision THA for PJI at our institution. Patients were matched for age and BMI. We recorded all costs associated with each procedure, including: OR time, equipment, length of hospital stay, readmission rates, and any other inpatient resource use. Unit costs were obtained using administrative data from the case costing department at London Health Sciences Centre. Billing fees associated with the procedure were obtained from the Ontario Schedule of Benefits. Descriptive statistics were used to summarise the demographic characteristics of patients, hospital costs and resource use data. Patients with PJI were compared to the matched cohort of primary THA using the t-test (for continuous variables), and the chi-square test (for categorical variables).

Twenty consecutive cases of revision THA were matched to 20 patients who underwent uncomplicated primary THA between 2006 and 2014. Periprosthetic infection was associated with a significant increase in hospital stay (26.5 vs. 2.0; p<0.001), clinic visits (9.5 vs. 3.8; p<0.001), readmission rates (12 vs. 1; p<0.001) and overall cost ($39 953 vs. $7 460; p<0.001) in comparison to the primary arthroplasty cohort.

Two-stage revision for infected THA is a significant economic burden to the healthcare system. Our data suggests a 5-fold increase in healthcare cost when compared to primary THA. This may be an important consideration when distributing resources among Canadian tertiary care centres.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 100 - 100
1 Nov 2016
Petis S Vasarhelyi E Lanting B Jones I Birmingham T Howard J
Full Access

Total hip arthroplasty (THA) is the most effective treatment modality for severe arthritis of the hip. Patients report excellent clinical and functional outcomes following THA, including subjective improvement in gait mechanics. However, few studies in the literature have outlined the impact of surgical approach on gait kinetics and kinematics. The purpose of this study was to determine the impact of surgical approach for THA on quantitative gait analysis.

Thirty patients undergoing THA for primary osteoarthritis of the hip were assigned to one of three surgical approaches (10 anterior, 10 posterior, and 10 lateral). A single surgeon performed each individual approach. Each patient received standardised implants at the time of surgery (cementless stem and acetabular component, cobalt chrome femoral head, highly cross-linked liner). Patients underwent 3D gait analysis pre-operatively, and at 6- and 12-weeks following the procedure. At each time point, temporal gait parameters, kinetics, and kinematics were compared. Statistical analysis was performed using one-way analysis of variance.

All three groups were similar with respect to age (p=0.27), body mass index (p=0.16), and the Charlson Comorbidity Index (p=0.66). Temporal parameters including step length, stride length, gait velocity, and percent stance and swing phase were similar between the groups at all time points. The lateral cohort had higher pelvic tilt during stance on the affected leg than the anterior cohort at 6-weeks (p=0.033). Affected leg ipsilateral trunk lean during stance was higher in the lateral group at 6-weeks (p=0.006) and 12-weeks (p=0.037) compared to the other cohorts. The anterior and posterior groups demonstrated an increased external rotation moment at 6-weeks (p=0.001) and 12-weeks (p=0.005) compared to the lateral group.

Although temporal parameters were similar across all groups, some differences in gait kinematics and kinetics exist following THA using different surgical approaches. However, the clinical relevance based on the small magnitude of the differences remains in question.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 104 - 104
1 May 2016
Petis S Howard J Lanting B Marsh J Vasarhelyi E
Full Access

Introduction

Total hip arthroplasty (THA) is a commonly performed surgical procedure for the treatment of hip arthritis. Approximately 50,000 THAs are performed annually in Canada. The costs incurred to the healthcare system are tremendous, amounting to anywhere between 4.3 and 7.3 billion dollars each year. Despite the substantial financial burden of THA to the Canadian healthcare system, few studies have provided accurate cost estimations of this procedure.

Purpose

To determine the impact of surgical approach on costs of THA from a hospital perspective, and provide an updated cost estimation of THA within a publically funded healthcare system.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 94 - 94
1 Jan 2016
Teeter M Lanting B Vasarhelyi E Ivanov T Vandekerckhove P Howard J Naudie D
Full Access

Increased modularity of total hip arthroplasty components has occurred, with theoretical advantages and disadvantages. Recent literature indicates the potential for elevated revision rates of modular neck systems and the potential for metallosis and ALVAL (Aseptic Lymphocyte dominated Vasculitis Associated Lesion) formation at the modular neck/stem site. Retrieval analysis of one modular neck implant design including SEM (Scanning Electron Microscopy) assessment was done and correlated to FEA (Finite Element Analysis) as well as clinical features of patient demographics, implant and laboratory analysis. Correlation of the consistent corrosion locations to FEA indicates that the material and design features of this system may result in a biomechanical reason for failure. The stem aspect of the modular neck/stem junction may be at particular risk.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 96 - 96
1 Jan 2016
Vasarhelyi E Vijayashankar RS Lanting B Howard J Armstrong K Ganapathy S
Full Access

Introduction

Fast track arthroplasty regimens require preservation of motor power to perform early rehabilitation and ensure early discharge (1). Commonly performed nerve blocks like femoral and Sciatic nerve blocks results in motor weakness thereby interfering with early rehabilitation and may also predispose to patient falls (2, 3). Hence, targeting the terminal branches of the femoral and sciatic nerves around the knee joint under ultrasound is an attractive strategy. The nerve supply of interest for knee analgesia are the terminal branches of the femoral nerve, the genicular branches of the lateral cutaneous nerve of thigh, obturator and sciatic nerves (4).

Methods

We modified the performance of the adductor canal block and combined it with US guided posterior pericapsular injection and lateral femoral cutaneous nerve block to provide analgesia around the knee joint. The femoral artery is first traced under the sartorius muscle until the origin of descending geniculate artery and the block is performed proximal to its origin. A needle is inserted in-plane between the Sartorius and rectus femoris above the fascia lata and 5 ml of 0.5% ropivacaine (LA) is injected to block the intermediate cutaneous nerve of thigh. The needle is then redirected to enter the fascia of Sartorius to deliver an additional 5ml of LA to cover the medial cutaneous nerve of thigh following which it is further advanced till the needle tip is seen to lie adjacent to the femoral artery under the Sartorius to perform the adductor canal block with an additional 15–20 ml of LA to cover nerve to vastus medialis, saphenous nerve and posterior division of the obturator nerve (Fig 1). The lateral cutaneous nerve of thigh is optionally blocked with 10 ml of LA near the anterior superior iliac spine between the origin of Sartorius and tensor fascia lata (Fig 2). The terminal branches of sciatic nerve to the knee joint is blocked by depositing 25 ml of local anesthetic solution between the popliteal artery and femur bone at the level of femoral epicondyles (Fig 3).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 47 - 47
1 Oct 2012
Vasarhelyi E Kunz M Rudan J
Full Access

The purpose of this study was to compare the accuracy and precision of acetabular component placement in cadavers using conventional techniques and CT-based individualised guides by both orthopaedic trainees and surgeons.

Seven cadaveric pelvises underwent a computerised tomography (CT) scan and a three-dimensional virtual model was created. Based on this model, cup orientation was planned for 40 degrees of inclination and 20 degrees of anteversion and an individualised guide was designed. A physical model of the individualised guide was created using a Rapid Prototyping machine (dimension SST, Stratasys, Inc., USA).

The pelvises were mounted in the lateral position and covered with a soft tissue envelope exposing only the acetabulum as would be visualised during a lateral approach to the hip. A total of 26 participants (16 orthopaedic surgery residents, 10 orthopaedic surgeons) were asked to use an acetabular cup impactor to place the cup in 40 degrees of inclination and 20 degrees of anteversion. This was first completed for all seven pelvises using conventional placement. Each participant was then instructed on how to use the individualised guide. They were provided with the guide and an individualised acetabular model to practice placement. Once they were comfortable with the system they were then asked to use the individualised guides in each of the seven pelvises.

An optoelectronic navigation system was used to evaluate the accuracy of the placement of the acetabular cup. An Optotrak Certus Motion Tracking System (Northern Digital Inc., Waterloo, Canada) was used. An optoelectronic marker was attached to the acetabulum and a combined pair-point and surface matching was performed. After the guide was placed in the acetabulum, a tracked axial pointing device was aligned inside the guidance cylinder and its three-dimensional orientation stored. The angle deviation between the achieved position and the planned cup orientation was calculated.

There were no statistically significant differences between trainees and surgeons in either conventional placement or use of the individualised guides. There were no statistically significant differences in anteversion between the groups. The individualised guide showed statistical improvement in the absolute deviation from planned inclination compared to conventional placement (4.2° vs. 9.1°, p< 0.001) as well as a reduction in standard deviation (3.3 vs. 5.9, p< 0.001).

The use of individualised guides can improve the accuracy and precision in the placement of acetabular component positioning. The current guide design controls well for inclination, which is a key factor in the function of a total hip arthroplasty. Based on this data, we will implement design changes to better address version of the component. Future work will likely include comparison to computer-assisted cup placement as well.