header advert
Results 21 - 40 of 52
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 27 - 27
1 Mar 2012
Ikemura S Yamamoto T Nishida K Motomura G Iwamoto Y
Full Access

Introduction

The objective of this study was to investigate the incidence of steroid-induced osteonecrosis (ON) among male and female rabbits.

Methods

Forty-seven adult rabbits (male, n = 24; female, n = 23) were injected once intramuscularly into the right gluteus medius muscle with 20 mg/kg of methylprednisolone acetate. Hematological examinations were performed just before and at 1 and 2 weeks after the corticosteroid injection. Two weeks after the injection, both femora and humeri were histopathologically examined for the presence of ON, and the bone marrow fat cells were examined morphologically.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 7 - 7
1 Mar 2012
Ikemura S Yamamoto T Motomura G Nakashima Y Mawatari T Iwamoto Y
Full Access

Introduction

Subchondral insufficiency fracture (SIF) needs to be differentiated from osteonecrosis. The purpose of this study was to evaluate the imaging and histopathological findings of patients 60 years or older with radiological evidence of subchondral collapse of the femoral head.

Methods

We reviewed 77 consecutive hips in 56 patients aged 60 years or older, which showed subchondral collapse on radiographs. According to the shapes of low-intensity bands on T1-weighted images of magnetic resonance imaging (MRI), the patients were divided into 2 groups. Group A showed a concavity of the articular surface: characteristic appearances of osteonecrosis, and Group B showed an irregular convexity of the articular surface: characteristic appearances of SIF.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 56 - 61
1 Jan 2012
Kawahara S Matsuda S Fukagawa S Mitsuyasu H Nakahara H Higaki H Shimoto T Iwamoto Y

In posterior stabilised total knee replacement (TKR) a larger femoral component is sometimes selected to manage the increased flexion gap caused by resection of the posterior cruciate ligament. However, concerns remain regarding the adverse effect of the increased anteroposterior dimensions of the femoral component on the patellofemoral (PF) joint. Meanwhile, the gender-specific femoral component has a narrower and thinner anterior flange and is expected to reduce the PF contact force. PF contact forces were measured at 90°, 120°, 130° and 140° of flexion using the NexGen Legacy Posterior Stabilized (LPS)-Flex Fixed Bearing Knee system using Standard, Upsized and Gender femoral components during TKR. Increasing the size of the femoral component significantly increased mean PF forces at 120°, 130° and 140° of flexion (p = 0.005, p < 0.001 and p < 0.001, respectively). No difference was found in contact force between the Gender and the Standard components. Among the patients who had overhang of the Standard component, mean contact forces with the Gender component were slightly lower than those of the Standard component, but no statistical difference was found at 90°, 120°, 130° or 140° of flexion (p = 0.689, 0.615, 0.253 and 0.248, respectively).

Upsized femoral components would increase PF forces in deep knee flexion. Gender-specific implants would not reduce PF forces.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 462 - 462
1 Nov 2011
Matsuo A Jingushi S Nakashima Y Yamamoto T Mawatari T Noguchi Y Shuto T Iwamoto Y
Full Access

Transposition osteotomy of the acetabulum (TOA) was the first periacetabular osteotomy for the osteoarthritis hips due to acetabular dysplasia, in which the acetabulum was transposed with articular cartilage. TOA improves coverage of the femoral head to restore congruity and stability, and also prevent further osteoarthritis deterioration and induce regeneration of the joint. Many good clinical outcomes have been reported for such periacetabular osteotomies for osteoarthritis of the hips at an early stage. In contrast, the clinical outcome is controversial for those hips at an advanced stage, in which the joint space has partly disappeared. The purpose of this study was to investigate whether TOA is an appropriate option for treatment of osteoarthritis of the hips at the advanced stage by comparing with matched control hips at the early stage.

Between 1998 and 2001, TOA was performed in 104 hips of 98 patients.

Sixteen of 17 hips (94%) with osteoarthritis at the advanced stage were examined and compared with 37 matched control hips at the early stage. The mean age at the operation was 48(38–56) and the mean follow-up period was 88 (65–107) months. TOA corrected the acetabular dysplasia and significantly improved containment of the femoral head.

No hips had secondary operations including THA. Clinical scores were also significantly improved in both of the groups. In the advanced osteoarthritis cases, there was a tendency for abduction congruity before transposition osteotomy of the acetabulum to reflect the clinical outcome.

TOA is a promising treatment option for the advanced osteoarthritis of the hips as well as for those patients at the early stage when preoperative radiographs show good congruity or containment of the joint.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 453 - 453
1 Nov 2011
Nakanishi Y Takashima T Higaki H Kamiyama E Miura H Iwamoto Y Touge M Umeno T Shimoto K
Full Access

An artificial articular cartilage is being investigated for use in joint replacement. The low elastic modulus lining on the bearing surface is used to promote a continuous lubricant film between the articulating surfaces and hence reduce both friction and wear.

Polyvinyl formal (PVF) as an artificial articular cartilage was proposed to prolong the service life of joint replacement. The major raw material of the PVF was a polyvinyl alcohol (PVA) hydrogel, which was one of the few polymers with hydrophilic properties. It is anticipated to realize a wide range of clinical applications due to its high water-holding capacity and high biocompatibility. However, a major problem with PVA hydrogel is its low wear resistance. The PVF was made by performing a chemical cross-linking reaction in PVA, and its pore diameter, porosity, and beam density could be controlled by varying the concentrations of cross-linking agent (formaldehyde) and catalyst (sulfuric acid).

The knee joint simulator was used for investigating the wear performance of the PVF. The load and motion cycles were taken from ISO 14243-3. The peak load was 2.6 kN, and the walking cycle was 1.0 seconds. The lower PVF specimen represented the flat tibial component of the joint, and the femoral component was artificial knee joint which made from Co-Cr-Mo alloy. The lubricant was a waterbased liquid containing the principal constituents of synovial fluid.

The PVF survived for more than 1.0 million cycles. Enlargement of the PVF creep deformation by prolongation of simulating time was not obvious. Although the tribological property in fatigue wear produced by ploughing friction was inadequate, it was obvious that the PVF was a potential material for developing a load bearing system with hydration lubrication.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1449 - 1456
1 Nov 2011
Fujii M Nakashima Y Yamamoto T Mawatari T Motomura G Iwamoto Y Noguchi Y

In order to clarify how intra-articular lesions influence the survival of a periacetabular osteotomy in patients with dysplasia of the hip, we performed an observational study of 121 patients (121 hips) who underwent a transposition osteotomy of the acetabulum combined with an arthroscopy. Their mean age was 40.2 years (13 to 64) and the mean follow-up was 9.9 years (2 to 18). Labral and cartilage degeneration tended to originate from the anterosuperior part of the acetabulum, followed by the femoral side. In all, eight hips (6.6%) had post-operative progression to Kellgren–Lawrence grade 4 changes, and these hips were associated with the following factors: moderate osteoarthritis, decreased width of the joint space, joint incongruity, and advanced intra-articular lesions (subchondral bone exposure in the cartilage and a full-thickness labral tear). Multivariate analysis indicated subchondral bone exposure on the femoral head as an independent risk factor for progression of osteoarthritis (p = 0.003). In hips with early stage osteoarthritis, femoral subchondral bone exposure was a risk factor for progression of the grade of osteoarthritis.

Although the outcome of transposition osteotomy of the acetabulum was satisfactory, post-operative progression of osteoarthritis occurred at a high rate in hips with advanced intra-articular lesions, particularly in those where the degenerative process had reached the point of femoral subchondral bone exposure.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 436 - 436
1 Nov 2011
Matsuda S Mizu-uchi H Miura H Iwamoto Y
Full Access

Total knee arthroplasty (TKA) has become one of the most successful procedures in orthopedics, and its survival rates are reportedly greater than 90% after 15 years.

Malpositioning of the component, however, can lead to various failures, such as aseptic loosening, instability, polyethylene wear, and patellar dislocation. Navigation systems for TKA have been developed to improve postoperative alignment. Many clinical and experimental studies of these navigation systems have shown that the accuracy of implanted components has improved.

We have compared the alignment of 150 total knee replacements implanted using a computed tomography-based navigation system and using the conventional alignment guide system when performed by a single surgeon. The knees were evaluated using full-length weight-bearing anteroposterior radiographs and computed tomography scans. For the navigated group, the average hip-knee-ankle angle, the femoral component angle to the femoral mechanical axis, and the tibial component angle to the mechanical tibial axis were 179.5, 89.4 and 89.7 degrees. The rotational femoral and tibial component angles to the planning axis were 0.6 and 0.3 degrees. The ideal angles of all alignments in the navigated group were obtained at significantly higher rates than in the conventional group. Our results demonstrated significant improvements in component positioning with CT-based navigation system, especially with respect to rotational alignment.

Recently, we established a new method for 3D reconstruction from postoperative CT images in order to accurately measure the alignment of the component relative to any designed plane. The results showed that the discrepancy between the two-dimensional and three-dimensional evaluations was 0.3 ± 1.8 (−2.7–3.4) degrees.

The coronal femoral angle for 36 knees (97.3%) and the coronal tibial angle for all the 37 knees (100%) were obtained within 3 degrees from the optimal angle. It is possible to measure the postoperative alignment for TKA more accurately on the basis of the defining plane. Three-dimensional analysis is necessary to evaluate the accuracy of the navigation system.

We conclude that navigation system is a very useful tool for achieving proper postoperative alignment. Controversy still exists regarding accuracy in rotational alignment with image-free navigation, but our results showed that CT-based system significantly improved accuracy of rotational alignment. We should keep using and improving the systems to establish more simplified and accurate systems.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1210 - 1216
1 Sep 2011
Mitsuyasu H Matsuda S Fukagawa S Okazaki K Tashiro Y Kawahara S Nakahara H Iwamoto Y

We investigated whether the extension gap in total knee replacement (TKR) would be changed when the femoral component was inserted. The extension gap was measured with and without the femoral component in place in 80 patients with varus osteoarthritis undergoing posterior-stabilised TKR. The effect of a post-operative increase in the size of the femoral posterior condyles was also evaluated. The results showed that placement of the femoral component significantly reduced the medial and lateral extension gaps by means of 1.0 mm and 0.9 mm, respectively (p < 0.0001). The extension gap was reduced when a larger femoral component was selected relative to the thickness of the resected posterior condyle. When the post-operative posterior lateral condyle was larger than that pre-operatively, 17 of 41 knees (41%) showed a decrease in the extension gap of > 2.0 mm. When a specially made femoral trial component with a posterior condyle enlarged by 4 mm was tested, the medial and lateral extension gaps decreased further by means of 2.1 mm and 2.8 mm, respectively.

If the thickness of the posterior condyle is expected to be larger than that pre-operatively, it should be recognised that the extension gap is likely to be altered. This should be taken into consideration when preparing the extension gap.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 184 - 187
1 Feb 2011
Motomura G Yamamoto T Yamaguchi R Ikemura S Nakashima Y Mawatari T Iwamoto Y

In order to investigate the mechanisms of collapse in osteonecrosis of the femoral head, we examined which part of the femoral head was the key point of a collapse and whether a collapsed region was associated with the size of the necrotic lesion. Using 30 consecutive surgically removed femoral heads we retrospectively analysed whole serial cut sections, specimen photographs, specimen radiographs and histological sections.

In all of the femoral heads, collapse consistently involved a fracture at the lateral boundary of the necrotic lesion. Histologically, the fractures occurred at the junction between the thickened trabeculae of the reparative zone and the necrotic bone trabeculae. When the medial boundary of the necrotic lesion was located lateral to the fovea of the femoral head, 18 of 19 femoral heads collapsed in the subchondral region. By contrast, when the medial boundary was located medial to the fovea, collapse in the subchondral region was observed in four of 11 femoral heads (p = 0.0011). We found that collapse began at the lateral boundary of the necrotic lesion and that the size of the necrotic lesion seemed to contribute to its distribution.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 781 - 786
1 Jun 2010
Zhao G Yamamoto T Ikemura S Motomura G Mawatari T Nakashima Y Iwamoto Y

We investigated the factors related to the radiological outcome of a transtrochanteric curved varus osteotomy in patients with osteonecrosis of the hip. We reviewed 73 hips in 62 patients with a mean follow-up of 12.4 years (5 to 31.1). There were 28 men and 34 women, with a mean age of 33.3 years (15 to 68) at the time of surgery. The 73 hips were divided into two groups according to their radiological findings: group 1 showed progression of collapse and/or joint-space narrowing; group 2 had neither progressive collapse nor joint-space narrowing. Both of these factors and the radiological outcomes were analysed by a stepwise discriminant analysis. A total of 12 hips were categorised as group 1 and 61 as group 2. Both the post-operative intact ratio and the localisation of the necrotic lesion correlated with the radiological outcome. The cut-off point of the postoperative intact ratio to prevent the progression of collapse was 33.6%, and the cut-off point to prevent both the progression of collapse and joint-space narrowing was 41.9%.

The results of this study indicate that a post-operative intact ratio of 33.0% is necessary if a satisfactory outcome is to be achieved after this varus osteotomy.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 141 - 141
1 Mar 2010
Matsushita A Nakashima Y Yamamoto T Mawatari T Motomura G Fujii M Iwamoto Y
Full Access

Combined anteversion (CA) is defined as the sum of the anteversions of acetabular and femoral components. In this study, we determined the appropriate CA in a variety of femoral versions using a total hip arthroplasty model. In addition, we also examined the usefulness of a changeable neck to improve range of hip motion in these cases.

Using a THA model, the range of motion (ROM) was tested in various CA values obtained by changing the anteversion of a cup in six increments after setting the femoral anteversion to 20° or 60° anteversion and 20° retroversion. The angle of the changeable neck was changed in 11 increments of 5°. To evaluate stability, the range of internal rotation at 90° flexion, the external rotation at 0° extension, and the range flexion was measured when any impingement occurred prior to dislocation. We defined the required ROM that met 40° internal rotation, 30° external rotation, and 110° flexion.

In normal 20° anteversion group, the required ROM was achieved with CA between 30° and 50° without using any changeable necks. In excessive anteversion 60° group, the range of external rotation was less than 10° even when the acetabular component was set 10° retroverted, because of the bone impingement between the greater trochanter and the posterior acetabulum. When 25° retroverted changeable neck was used, ROM improved to 30° external rotation and satisfied the required ROM. In 20° retroversion group, the internal rotation angle was 31° even when the acetabular component was opened 35° anteverted, because of anterior neck-liner impingement. When 25° anteverted changeable neck was used, ROM improved to 39° internal rotation and 130° flexion.

In cases with normal anteversions, the required ROM can be achived by adjusting CA. In cases with excessive anteversion or retroversion, there was a limitation of the CA adjustment. The use of changeable necks allows for further improvement of ROM by compensating femoral anteversions.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 142 - 142
1 Mar 2010
Jingushi S Murata D Nakashima Y Yamamoto T Mawatari T Iwamoto Y
Full Access

Treating Crowe type 3 or 4 of hips tends to be technically difficult when performing total hip arthroplasty (THA) due to the severely dysplastic acetabulum and proximal femur in addition to a high dislocation of the hip. Since the socket is limited to being placed at the original hip center, a femoral shortening osteotomy is often required in order to prevent neurovascular problems. This osteotomy will need the stability of the femoral stem with both the proximal and the distal femoral bones. We used the modular S-ROM stem, which has a valuable proximal structure and a distal flute structure to stabilize the stem with the proximal and distal femoral fragments. The purpose of this study was to report the clinical and radiographic results of the primary THA with a shortening osteotomy while also using the S-ROM prosthesis.

Between 1994 and 2004, primary THA using the S-ROM prosthesis was performed on 7 hips in 6 cases (1 male, 5 females). Crowe type 3 or 4 was observed in one and 6 hips, respectively. The mean age at operation was 56 years old (range 51~60). The mean follow-up period was 41 months (range 24~56 months). Four hips had previously undergone a subtrochanteric valgus osteotomy. All hips underwent a step-cut femoral osteotomy at the proximal metaphysis for the shortening and/or correction of angulations with on-lay chip bone grafts. All of the used stems were straight type. The clinical outcome was evaluated using the clinical scoring system of hip joints established by the Japanese Orthopaedic Association (JOA). According to a 100 point scale, pain was determined to be 40, ROM was 20, gait was 20 and ADL was 20.

No hips had undergone any revision surgery as of the most recent follow-up. Union was achieved at the osteotomy site in all hips. Neither osteolysis nor a loosening of the implant was radiographically observed. The mean JOA score before THA and at the last follow-up was 41 (31–48) and 81 (62–91) points, respectively. The mean postoperative days to start full weight bearing was 53 days (range 49~70). In two cases (28%), a procedure using circular wiring was performed to treat a crack in the proximal femur.

The S-ROM prosthesis was thus found to be useful for primary THA with a shortening metaphyseal femoral osteotomy for hips in patients with Crowe type 3 or 4 developmental dysplasia.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1180 - 1185
1 Sep 2008
Hamai S Miura H Higaki H Shimoto T Matsuda S Iwamoto Y

Mechanical failure because of wear or fracture of the polyethylene tibial post in posteriorly-stabilised total knee replacements has been extensively described. In this study of 12 patients with a clinically and radiologically successful NexGen LPS posteriorly-stabilised prosthesis impingement of the anterior tibial post was evaluated in vivo in three dimensions during gait using radiologically-based image-matching techniques.

Impingement was observed in all images of the patients during the stance phase, although the NexGen LPS was designed to accommodate 14° of hyperextension of the component before impingement occurred. Impingement arises as a result of posterior translation of the femur during the stance phase. Further attention must therefore be given to the configuration of the anterior portion of the femoral component and the polyethylene post when designing posteriorly-stabilised total knee replacements.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1025 - 1031
1 Aug 2008
Mizu-uchi H Matsuda S Miura H Okazaki K Akasaki Y Iwamoto Y

We compared the alignment of 39 total knee replacements implanted using the conventional alignment guide system with 37 implanted using a CT-based navigation system, performed by a single surgeon. The knees were evaluated using full-length weight-bearing anteroposterior radiographs, lateral radiographs and CT scans.

The mean hip-knee-ankle angle, coronal femoral component angle and coronal tibial component angle were 181.8° (174.2° to 188.3°), 88.5° (84.0° to 91.8°) and 89.7° (86.3° to 95.1°), respectively for the conventional group and 180.8° (178.2° to 185.1°), 89.3° (85.8° to 92.0°) and 89.9° (88.0° to 93.0°), respectively for the navigated group.

The mean sagittal femoral component angle was 85.5° (80.6° to 92.8°) for the conventional group and 89.6° (85.5° to 94.0°) for the navigated group.

The mean rotational femoral and tibial component angles were −0.7° (−8.8° to 9.8°) and −3.3° (−16.8° to 5.8°) for the conventional group and −0.6° (−3.5° to 3.0°) and 0.3° (−5.3° to 7.7°) for the navigated group.

The ideal angles of all alignments in the navigated group were obtained at significantly higher rates than in the conventional group. Our results demonstrated significant improvements in component positioning with a CT-based navigation system, especially with respect to rotational alignment.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 179 - 179
1 Mar 2008
Okazaki K Miura H Matsuda S Mawatari T Takeuchi N Iwamoto Y
Full Access

It is recommended in the TKA operation to balance the tension of soft tissues to make the rectangular gap in both flexion and extension because significant imbalance may result in eccentric stress on the polyethylene insert. However, no intensive research has been done on the medial and lateral laxity of the normal knee

X-ray of 50 normal knees were taken under the varus or valgus stress in both extension and flexion at 80 degrees. The angle of lines on the femoral condyles and tibia plateau was measured. The same methods were also done for the 20 osteoarthritis knees.

In extension of the normal knees, the mean angle was 5.06 degrees in varus stress and was 2.46 degrees in valgus stress. In flexion of the normal knees, the mean angle was 5.04 degrees in varus stress and was 1.82 degrees in valgus stress. Therefore, the lateral laxity was significantly larger than the medial laxity in both extension and flexion (p< 0.0001). The lateral laxity was significantly larger also in osteoarthritis knees (p< 0.0001).

There are some arguments about the priority to make the perfect rectangular gaps. The methods to measure the tension of soft tissues during the operation are not accurate and does not always reflect the post-operative tensions. Furthermore, the tension during the operation may be different from dynamic phase such as walking and standing. The present study showed that the mediolateral laxity was asymmetrical in the normal knees. This imbalance may be necessary for the medial pivot movement of the normal knee. These results suggest that a slight lateral laxity is acceptable during TKA operation and may be beneficial to achieve the normal kinematics especially for the cruciate retaining prosthesis.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 176 - 176
1 Mar 2008
Miura H Matsuda S Okazaki K Iwamoto Y
Full Access

Minimally invasive surgery (MIS) for unicompartmental knee arthroplasty (UKA) has become increasingly popular. However, wound problems may be encountered with longitudinal skin incisions. This probably occurs because the skin is under excessively high tension during MIS. We have been using transverse incisions for MIS-UKA. We describe the surgical technique and an experimental study for assessing blood flow in the skin around the knee.

A 5–7 cm transverse skin incision was made from the medial edge of the patella at the level of 1–2 cm proximal to the joint line. The capsule was incised along the medial parapatellar up to the proximal two-thirds of the patella, and a few cm were also cut along the distal end of the vastus medialis. Because skin on the anterior aspect of the knee is more flexible in the longitudinal direction, exposure is easy even with a small incision.

Experimental study: We measured the direction of blood flow on the anterior aspect of the knee using laser flowmetry. Nine normal subjects were examined. A probe was attached to the skin on the medial parapatellar region, and two 7 cm long parallel depressors were applied bilaterally on the sides of the probe. The depressors were placed longitudinally or transversely under 30N of compression force, and then blood flow was recorded.

Blood flow was markedly increased due to congestion when the depressor was placed longitudinally. On the contrary, changes in blood flow were significantly lower when the depressor was placed transversely.

Transverse incision can lead to better exposure and permit an smaller incision. Moreover, transverse incisions are less invasive to the skin’s circulation and leave less distinctive scars than longitudinal incisions.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 176 - 177
1 Mar 2008
Miura H Matsuda S Okazaki K Higaki H Iwamoto Y
Full Access

Kinematics of mobile bearing TKA has been evaluated by fluoroscopic studies. However, these studies focused on the relative motion between the femoral component and the tibial tray. The purpose of this study was to investigate the kinematics of the polyethylene insert in mobile bearing TKA under dynamic conditions using a custom-made 6-DOF kneesimulator.

The mobile bearing TKA used in this study had a ågstopåh on the tibial tray, allowing rotation and translation. The implants were mounted on the knee simulator. Vertical load and 5-DOF motions were regulated according to the kinematic data from the literature. The knee simulating test was conducted under three different conditions including a static condition and dynamic conditions of 0.5 Hz and 1.0 Hz. Four metal balls mounted on the insert were observed with two cameras, and position of the insert was calculated. Contact pressure on the insert was also measured using a tactile sensor.

Under the static condition, the femoral component kept almostfull contact with the insert. However, the insert shifted posteriorly with impingement to the stop under the 0.5 Hz condition. Under the 1.0 Hzcondition, antero-posterior translation of the insert was larger with impingement to the stop in both directions and contact pressure was greater.

To our knowledge, no study on the motion of the insert of the mobile bearing TKA has been reported. In the present study, the insert showed different motion and contact stress according to the given condition, in spite of the same relative motion between the femoral component and the tibial tray.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 725 - 729
1 Jun 2007
Ikemura S Yamamoto T Jingushi S Nakashima Y Mawatari T Iwamoto Y

Transtrochanteric curved varus osteotomy was designed to avoid some of the disadvantages of varus wedge osteotomy, such as post-operative leg-length discrepancy. In this retrospective study we investigated the leg-length discrepancy and clinical outcome after transtrochanteric curved varus osteotomy undertaken in patients with osteonecrosis of the femoral head. Between January 1993 and March 2004, this osteotomy was performed in 42 hips of 36 patients with osteonecrosis of the femoral head. There were 15 males and 21 females with a mean age at surgery of 34 years (15 to 68). The mean follow-up was 5.9 years (2.0 to 12.5). The mean pre-operative Harris hip score was 64.0 (43 to 85) points, which improved to a mean of 88.7 (58 to 100) points at final follow-up. The mean varus angulation post-operatively was 25° (12° to 38°) and the post-operative mean leg-length discrepancy was 13 mm (4 to 25). The post-operative leg-length discrepancy showed a strong correlation with varus angulation (Pearson’s correlation coefficient; r = 0.9530, p < 0.0001), which may be useful for predicting the leg-length discrepancy which can occur even after transtrochanteric curved varus osteotomy.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1643 - 1646
1 Dec 2005
Miura H Matsuda S Okazaki K Kawano T Kawamura H Iwamoto Y

We have previously developed a radiographic technique, the oblique posterior condylar view, for assessment of the posterior aspect of the femoral condyles after total knee arthroplasty. The purpose of this study was to confirm the validity of this radiographic view based upon intra-operative findings at revision total knee arthroplasty. Lateral and oblique posterior condylar views were performed for 11 knees prior to revision total knee arthroplasty, and radiolucent lines or osteolysis of the posterior aspect of the femoral condyles were identified. These findings were compared with the intra-operative appearance of the posterior aspects of the femoral condyles. Statistical analysis showed that sensitivity and efficacy were significantly better for the oblique posterior condylar than the lateral view. This method can, therefore, be considered as suitable for routine follow-up radiographs of the femoral component and in the pre-operative planning of revision surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 483 - 488
1 Apr 2005
Nakayama K Matsuda S Miura H Higaki H Otsuka K Iwamoto Y

We measured the contact areas and contact stresses at the post-cam mechanism of a posterior-stabilised total knee arthroplasty when a posterior force of 500 N was applied to the Kirschner Performance, Scorpio Superflex, NexGen LPS Flex Fixed, and NexGen LPS Flex Mobile knee systems. Measurements were made at 90°, 120°, and 150° of flexion both in neutral rotation and 10° of internal rotation of the tibial component. Peak contact stresses at 90°, 120°, and 150° were 24.0, 33.9, and 28.8 MPa, respectively, for the Kirschner; 26.0, 32.4, and 22.1 MPa, respectively, for the Scorpio; and 34.1, 31.5, and 32.5 MPa, respectively, for the NexGen LPS Flex Fixed. With an internally rotated tibia, the contact stress increased significantly with all the fixed-bearing arthroplasties but not with the NexGen LPS Flex Mobile arthroplasty. The post-cam design should be modified in order to provide a larger contact area whilst avoiding any impingement and edge loading.