header advert
Results 21 - 40 of 51
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 150 - 150
1 Jan 2016
Garcia-Rey E Garcia-Cimbrelo E
Full Access

Background

Cup migration and bone graft resorption are some of the limitations after acetabular impaction bone grafting (IBG) technique in revision hip surgery when used for large segmental defects. We asked whether the use of a metallic mesh may decrease the appearance of this complication. We compared the appearance of loosening in patients with a bone defect 3A or 3B according to Paprosky.

Materials and Methods

We assessed 204 hips operated with IBG and a cemented cup according to Slooff et al between 1997 and 2004. There were 100 hips with a preoperative bone defect of 3A and 104 with a 3B. We used 142 medial and/or rim metallic meshes for uncontained defects. The mean follow-up for unrevised cups was 10.4 years. We detemined postoperative radiological cup position and acetabular reconstruction of the hip center according to Ranawat in both groups. We assessed the appearance of radiological loosening and resorption of the graft.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 152 - 152
1 Jan 2016
Garcia-Rey E Garcia-Cimbrelo E
Full Access

Introduction

Dislocation is one of the most important complications after primary total hip replacement (THR). The low incidence of this finding makes it difficult to analyse the possible risk factors. The surgical technique can also influence this rate through cup position or an adequate reconstruction of the hip.

We assessed the demographic data and radiological reconstruction of the hip related to the appearance of dislocation after primary THR.

Material and Methods

1414 uncemented THRs were recorded from our Local Joint Registry. The mean age of the patients was 60.1 years old (range, 14 to 95), and the mean weight was 73.3 kg (42 to 121). There were 733 men and 974 patients were classified with an activity level of 4 or 5 according to Devane. The most frequent diagnosis was primary osteoarthritis, 795 hips, followed by avascular necrosis 207 hips. An alumina-on-alumina THR was implanted in 703 hips and a metal-on-polyethylene THR in 711 hips. A femoral head size of 28 mm was used in 708 hips and 32 mm in 704. Radiological cup position was assessed using the acetabular abduction angle, the height of the center of the hip, and the horizontal distance of the cup. Cup anteversion was measured according to Widmer and the reconstruction of the center of rotation of the hip according to Ranawat. The radiographic reconstruction of the abductor mechanism was measured using two variables: the lever arm and the height of the greater trochanter.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 326 - 332
1 Mar 2013
García-Rey E García-Cimbrelo E Cruz-Pardos A

Between 1999 and 2001, 90 patients underwent total hip replacement using the same uncemented acetabular and femoral components with a 28 mm metallic femoral head but with prospective randomisation of the acetabular liner to either Durasul highly cross-linked polyethylene or nitrogen-sterilised Sulene polyethylene. We assessed 83 patients at a minimum follow-up of ten years. Linear penetration of the femoral head was estimated at six weeks, six and 12 months and annually thereafter, using the Dorr method, given the non-spherical shape of the acetabular component.

There was no loosening of any component; only one hip in the Sulene group showed proximal femoral osteolysis. The mean penetration of the femoral head at six weeks was 0.08 mm (0.02 to 0.15) for the Durasul group and 0.16 mm (0.05 to 0.28) for the Sulene group (p = 0.001). The mean yearly linear penetration was 64.8% lower for the Durasul group at 0.05 mm/year (sd 0.035) for the Sulene group and 0.02 mm/year (sd 0.016) for the Durasul (p < 0.001). Mean linear femoral head penetration at ten years was 61% less in the Durasul than Sulene group. Highly cross-linked polyethylene gives excellent results at ten years.

Cite this article: Bone Joint J 2013;95-B:326–32.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 243 - 243
1 Sep 2012
Bragdon C Malchau H Greene M Doerner M Emerson R Gebuhr P Huddleston J Cimbrelo E
Full Access

Introduction

Proper cup positioning is a critical component in the success of total hip arthroplasty surgery. A multicenter study has been initiated to study a new type of highly cross-linked polyethylene. This study provides a unique opportunity to a review the acetabular cup placement of over 500 patients implanted in the past 2 years from 13 medical centers from the U.S., Mexico, and Europe.

Methods

482 patients have received primary total hip arthroplasty using components from a single manufacturer in 5 centers in the US and Mexico and 7 centers in Europe. The acetabular anteversion and inclination were measured in post-operative radiographs. An acceptable window of cup position is defined at 5–25° of anteversion and 30–45° of inclination.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1457 - 1464
1 Nov 2011
Garcia-Cimbrelo E Garcia-Rey E Cruz-Pardos A

We report the results of 79 patients (81 hips) who underwent impaction grafting at revision hip replacement using the Exeter femoral stem. Their mean age was 64 years (31 to 83). According to the Endoklinik classification, 20 hips had a type 2 bone defect, 40 had type 3, and 21 had type 4. The mean follow-up for unrevised stems was 10.4 years (5 to 17).

There were 12 re-operations due to intra- and post-operative fractures, infection (one hip) and aseptic loosening (one hip). All re-operations affected type 3 (6 hips) and 4 (6 hips) bone defects. The survival rate for re-operation for any cause was 100% for type 2, 81.2% (95% confidence interval (CI) 67.1 to 95.3) for type 3, and 70.8% (95% CI 51.1 to 90.5) for type 4 defects at 14 years. The survival rate with further revision for aseptic loosening as the end point was 98.6% (95% CI 95.8 to 100). The final clinical score was higher for patients with type 2 bone defects than type 4 regarding pain, function and range of movement. Limp was most frequent in the type 4 group (p < 0.001). The mean subsidence of the stem was 2.3 mm (sd 3.7) for hips with a type 2 defect, 4.3 mm (sd 7.2) for type 3 and 9.6 mm (sd 10.8) for type 4 (p = 0.022).

The impacted bone grafting technique has good clinical results in femoral revision. However, major bone defects affect clinical outcome and also result in more operative complications.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 129 - 129
1 May 2011
García-Rey E Garcia-Cimbrelo E Cruz-Pardos A
Full Access

Acetabular bone structure is not the same in all patients and can be defined by the radiolucent triangle superior to the acetabulum. We ask if the acetabular anatomy determines the initial cup fixation and screws use.

We have assessed 205 hips in which a Cerafit cementless cup was implanted. According to Dorr et al., acetabulae were classified as type A, in which the radiolucent triangle had an isosceles shape (86 hips), type B, in which the triangle extended into the teardrop (90 hips), and type C which had a right-angle triangle (29 hips). The use of screws was decided at the time of surgery and according to cup stability, not acetabular anatomy.

Avascular necrosis and inflammatory arthritis were the most frequent diagnoses in type A hips, osteoarthritis in type B, and dysplasia in type C. Women were more frequent in types A and C (p< 0.001). The use of screws was more frequent in women (p< 0.001) and in type A (34.9%) and type C hips (62.1%) than in type B hips (20.0%) (p< 0.001). The multivariate logistic regression model showed the acetabular type (p=0.11) and gender (p=0.003) as independent factors. Acetabular types A (OR=1.98, 95% CI: 0.922–4.208, p=0.075) and C (OR=5.09, 95% CI: 1.74–14.9, p=0.003) increase the risk for screw use. Men have a lower risk for screw use (OR=0.329, 95% CI: 0.16–0.68, p=0.003).

Acetabular anatomy and gender determine the use of screws in cementless cups. Continued follow-up is necessary to determine if screws results in less loosening and osteolysis.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 183 - 184
1 May 2011
Vallés G Vilaboa N Munuera L García-Cimbrelo E
Full Access

The biological response to implant-derived wear particles is recognized as one of the main factors involved in the development of periprosthetic osteolysis. Wear particles induce a foreign-body inflammatory response that results in the formation of a periprosthetic membrane and progresses over time to aseptic loosening and implant failure. Upon exposure to particles, macrophages and other cell types release inflammatory cytokines to the periprosthetic milieu such as inter-leukin-1 beta (IL-1 beta, tumor necrosis factor-alpha (TNF-alpha) and interleukin-6 (IL-6) which contribute to bone resorption. Heat shock proteins (HSP) are intra-cellular proteins involved in the maintenance of cellular homeostasis. The stress inducible form of the Hsp70 family protein, Hsp72, has been detected in circulation, acting as a factor capable of regulating pro-inflammatory cytokines secretion and it has been demonstrated that induces the production of pro-inflammatory cytokines via the CD14 and Toll-like receptor-mediated signal transduction pathway.

We hypothesized that Hsp72 could be involved in the inflammatory response to wear particles. To this aim, we investigated Hsp72 and its receptor, CD14, in interfacial membrane specimens obtained from patients undergoing revision surgery for aseptic loosening of uncemented acetabular cups (n=7). Distribution of both proteins was assessed by immunofluorescence and examined by confocal laser scanning microscopy. Hsp72 was detected in the periprostehetic membranes, colocalizing with CD14. Explants of membranes were cultured in vitro and levels of Hsp72 and IL-6 were determined by ELISA after 24, 48 and 72 h (n=9). Cultured membranes released IL-6 to culture medium in a time-dependent manner (p< 0.05), while Hsp72 levels decreased during same observation period (p< 0.05). These data suggest that, rather than being produced by the periprosthetic tissue, Hsp72 might be recruited by CD14+ cells from extracellular fluids. In this regard, preliminary data indicated that soluble Hsp72 levels in sera from patients undergoing revision surgery due to aseptic loosening were significantly lower than those from age-matched control subjects (n=6; p< 0.001). To investigate the involvement of Hsp72 in the inflammatory response to wear particles, we used a cell culture model of THP-1 cells driven to the monocyte/macrophage differentiation pathway. These cells were exposed to titanium particles of phagocytosable sizes, either in the presence or absence of exogenously added Hsp72. results obtained to date indicate that Hsp72 is able to modulate the titanium-induced TNF-alpha, IL-1 beta and IL-6 secretion (p< 0.05). Altogether, our data suggest that Hsp72 could be a novel mediator involved in wear particles-induced osteolysis and prosthetic failure.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 515 - 515
1 Oct 2010
Garcia-Cimbrelo E Cruz-Pardos A Garcia-Rey E
Full Access

Introduction: Severe stress shielding and radiographic cortical changes in the proximal femur are frequent after extensively porous-coated stem in revision surgery. We have analyzed the evolution of the femoral cortex at different levels and related factors.

Material and Methods: We assessed 95 extensively porous-coated stems in revision surgery with a minimum 5-year follow-up (Mean 10.2 years). 77 hips were revised due to aseptic loosening and 18 due to periprosthetic fractures. Extended osteotomy was used in 29 hips. No cortical struts were used. Preoperative and postoperative osteoporosis was graded according to Moreland and bone defect according to Paprosky. Femoral cortex width was measured at different levels in the immediate postoperative radiograph, at 3, 6 and 12 months and at the last follow-up.

Results: There were 2 re-revisions for aseptic loosening. Radiographic ingrowth fixation was more frequent in minor intraoperative bone defects (p=0.011). Preoperative osteoporosis was related to the width of the medial and lateral cortex. Medial cortical thickness increased at different levels with a mean increase of 13.4% (p< 0.001) and the lateral cortical thickness showed a mean decrease of 2.7% at the proximal level. The femoral medial cortex tended to show a higher slope trend in periprosthetic fractures (p=0.015). The outside femoral diameter increased more rapidaly with an extended trochanteric osteotomy (p=0.007). The slope trend of the lateral and medial cortex was significantly higher at proximal levels in hips with a 10-inch stem (p=0.015).

Conclusions: Although without clinical relevance at the end of follow-up, femoral medial cortical thickness increased while frequently lateral cortical thickness decreased over time after an extensively porous -coated stem in revision hip surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1363 - 1369
1 Oct 2010
Garcia-Cimbrelo E Garcia-Rey E Cruz-Pardos A Madero R

Revision surgery of the hip was performed on 114 hips using an extensively porous-coated femoral component. Of these, 95 hips (94 patients) had a mean follow-up of 10.2 years (5 to 17). No cortical struts were used and the cortical index and the femoral cortical width were measured at different levels.

There were two revisions for aseptic loosening. Survivorship at 12 years for all causes of failure was 96.9% (95% confidence interval 93.5 to 100) in the best-case scenario. Fibrous or unstable fixation was associated with major bone defects. The cortical index (p = 0.045) and the lateral cortical thickness (p = 0.008) decreased at the proximal level over time while the medial cortex increased (p = 0.001) at the proximal and distal levels. An increase in the proximal medial cortex was found in patients with an extended transtrochanteric osteotomy (p = 0.026) and in those with components shorter than 25 cm (p = 0.008).

The use of the extensively porous-coated femoral component can provide a solution for difficult cases in revision surgery. Radiological bony ingrowth is common. Although without clinical relevance at the end of follow-up, the thickness of the medial femoral cortex often increased while that of the lateral cortex decreased. In cases in which a shorter component was used and in those undertaken using an extended trochanteric osteotomy, there was a greater increase in thickness of the femoral cortex over time.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 605 - 605
1 Oct 2010
Cordero-Ampuero J Esteban J Garcia-Cimbrelo E Hernandez A Noreña I
Full Access

Introduction: Papers about high-virulence infections are not usual, results contradictory, and orthopaedic outcomes not described.

Purpose: to compare infectious and orthopaedic results after late arthroplasty infections by single vs. polymicrobial isolates, low vs. high-virulence, and Gram-positive vs. Gram-negative organisms, when treated by exchange surgery plus long cycles of combined oral antibiotics.

Patients and Methods: A late arthroplasty infection was diagnosed in 68 consecutive patients (48 female) of 72.2(+/−10.2) years (37 hips/31 knees).

Cultures were polymicrobial in 22 cases and by Gram-positive in 55 (80.9%). Highly-resistant organisms: methicillin-resistant Staphylococcus (36 patients) and ESBL-producing Enterobacteriaceae (2 patients). “Problematic-treatment”: Enterococcus (6 patients), Pseudomonas (3 patients), non-fermenting Gram-negative (2), moulds (1).

Oral antibiotic selection: according to bacterial sensitivity, biofilm and intracellular effectiveness. Protocolized surgery: two-stage exchange. Average follow-up: 4.7+/−2.7 years (1–11).

Healing of infection is diagnosed if absence of clinical, serological and radiological signs of infection during the whole follow-up. Orthopaedic outcome is evaluated by HHS for hips and by KSCRS for knees.

Results: Surgery was not possible in 7 infections (rejected by patients), and reimplantation in 17 additional cases (patients died shortly after first surgery, rejected 2nd surgery, or was contraindicated because of medical reasons).

Healing of infection: 59/68 patients (86.8%), 32/37 hips (86.5%) and 27/31 knees (87.1%). Infection not healed: 7/68 cases (10.3%) (4/37 hips, 3/31 knees) (5 by highly-resistant and 1 by “problematic-treatment” bacteria). There are no differences between hips and knees (p=0.55).

Orthopaedic Results: HHS averages 80.5+/−16.2 (81+/−16 in healed infection, 56+/−23.5 in persistent infection). KSCRS averages 77.2/58.1 +/− 19.8/24.5 in healed infections, 32.6/0+/−25.8/0 in persistent infections. Infective and orthopaedic results present a strong statistical correlation in hips (p=0.016) and knees (p=0.0001).

Statistically significant differences are not found when comparing subgroups according to Gram stain (p=0.43), multiple vs single bacteria (p=0.47 infective, p=0.71 orthopaedic), highly-resistant bacteria (p=0.2 infective, p=0.1/0.5 orthopaedic), or “problematic-treatment” (p=0.68).

Conclusions:

A strong statistical correlation appears between infective and orthopedic results after late arthroplasty infections.

With the number of cases presented significant differences in infective or in orthopaedic results are not found when comparing single vs. polymicrobial, gram-negative vs. gram-positive, high vs. low antimicrobial resistance and “problematic-treatment” infections.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 82 - 82
1 Mar 2010
García-Rey E Pardos AC García-Cimbrelo E
Full Access

Introduction and Objectives: We compared the clinical and radiographic results of patients with JRA and primary arthritis using a non-cemented THR with an alumina-alumina THA.

Materials and Methods: We studied 29 THR (Cerafit cup and Multicone stem) implanted in 19 patients with JRA in group 1 and 135 with primary arthritis in group 2. Mean follow-up was 59.0 months. It was seen that 13 hips in group 1 had moderate-severe acetabular protrusion and allograft was used in 12 hips. The center of rotation was determined pre and postoperatively in group 1 according to Ranawat.

Results: In group 1 age (p< 0.001), weight (p< 0.001), and level of activity (p< 0.001) were less. Type A acetabulum (p=0.014) and a cylindrical femur (p< 0.01), according to Dorr, were more frequent in group 1. There was no noise or alumina breakage. There were two intraoperative femur fractures in group 1. There was a revision of 1 cup in group 1 and infection of 1 stem in group 2. In most of the group 1 cases anatomical position was recovered (p< 0.001). The preoperative center of rotation of the hip with acetabular protrusion was 23.2 mm and in the postoperative X-ray 5.6 mm.

Discussion and Conclusions: In spite of the differences, THR with alumina-alumina allows similar results to be obtained in the medium term in patients with JRA. The use of an allograft in those patients with severe acetabular protrusion makes it possible to reconstruct the center of rotation of the hip.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 79 - 79
1 Mar 2010
García-Rey E Pardos AC García-Cimbrelo E
Full Access

Introduction and Objectives: We compared the clinical and radiological results in patients under and over 40 years of age who had received a non-cemented alumina-alumina hip replacement.

Materials and Methods: We studied 337 Cerafit acetabular cups implanted in 4 hospitals in association with Multicone-Hydroxyapatite stems with alumina-alumina bearing surfaces. Group 1 consisted of 63 patients under 40 years of age and group 2 of 274 patients over 40 years of age. Mean follow-up was 59.0 months. Demographic data and clinical and radiological results of both groups were compared.

Results: There were no cases of primary arthritis in group 1, however severe hip dysplasia and juvenile rheumatoid arthritis were frequent (p< 0.001). Weight (p< 0.001) and degree of activity (p=0.003) were greater in group 2. Preoperative function (p=0.03) and mobility (p< 0.001) were worse in group 1. There were 3 cup revisions in group 1 and 4 (including an alumina breakage) in group 2. Survival with no revision due to any cause was 91.4+5.1% in group 1 and 97.0+ 1.1 in group 2 (p=0.4007). There were no noises. Clinical and radiological results were similar in both groups.

Discussion and Conclusions: Diagnoses were different in both groups, the younger patients were in worse conditions. In spite of these differences, the alumina-alumina prosthesis showed similar results in both groups in the medium term. Long-term follow-ups are necessary to confirm these results.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 318 - 318
1 May 2009
Garcia-Rey E García-Cimbrelo E Cruz A Ortega-Chamarro J
Full Access

Introduction and purpose: Highly cross-linked polyethylenes (HXLPE) sterilized in an air-free environment have been used to prevent osteolysis and loosening of implants. This prospective randomized study analyzes the results of a series in which one single type of prosthesis but made with one of two different kinds of polyethylene (PE) has been used.

Materials and methods: We assessed 45 Allofit cups with a Sulene-PE liner (sterilized in nitrogen) and 45 with Durasul-PE liner (highly cross-linked) associated with an Alloclassic stem (femoral head: 28 mm) with a minimum follow-up of 5 years (mean 66.3 months). Femoral head penetration was analyzed by means of a digital program at 6 weeks, and at 6 and 12 months and once a year, using the Dorr method given the non-spherical shape of the cups.

Results: All assessed hips had good outcomes determined clinically and by x-rays. There was no loosening of any component. There were no radiolucent lines or osteolysis. Femoral head penetration at 6 weeks was 47.4% less in the Durasul group (0.19+0.06 mm for the Sulene-PE and 0.09+0.03 for the Durasul-PE [p< 0.0001]). Mean annual penetration was 20% less in the Durasul group (0.04+0.02 and 0.008+0.008 [p< 0.0001] respectively. The differences increased by the third year. Mean penetration at 5 years was 39.1% less in the Durasul group (p< 0.0001).

Conclusions: There was significant femoral reduction in the Durasul-PE group. Long term results are necessary to confirm that these prostheses lead to a lower rate of osteolysis.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 318 - 318
1 May 2009
García-Cimbrelo E Murcia A Blanco A Marti E
Full Access

Introduction and purpose: Different bearing surfaces have been used to prevent osteolysis, such as alumina-alumina. We present here an analysis of the results of a prospective multi-center study of complications related to the use of alumina-alumina bearings.

Materials and methods: In 4 hospitals 319 cups with hydroxyapatite stems and alumina-alumina bearing surfaces were implanted with a mean follow-up of 5.6 years (range: 3–8). The mean age of the patients was 52.7 (range: 14–70). Alumina wear was calculated by means of a special program.

Results: Revision was performed of 5 cups and 2 stems. In one hip with a horizontal acetabular angle (35°) and a thin alumina liner (size 50/32), an acetabular liner fracture occurred 36 months after surgery. The probability of not undergoing revision due to any cause was 96.9% (CI 95%:94.7–99.1%). None of the patients reported any type of noise. All the non-revised cases showed good results both on clinical and X-ray exam at the end of the follow-up. The difference between the center of the head of the femur and the center of the head of the cup at 6 weeks after surgery was −2.45+0.53 mm, with no further changes seen during the follow-up.

Conclusions: These data suggest that the prosthetic alumina-alumina bearing surface has excellent results over 5 years and that alumina fractures are infrequent. No changes were seen in terms of the penetration of the femoral head in any case. Longer follow-ups are necessary to determine if the reduction of wear translates into less osteolysis and loosening.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 327 - 332
1 Mar 2009
García-Rey E García-Cimbrelo E Cordero-Ampuero J

We reviewed 111 hemispherical Duraloc series-500 acetabular components with a minimum follow-up of 12 years. The mean clinical and radiological follow-up was 13.4 years (12 to 15). A Profile hydroxyapatite-coated anatomical femoral component was used in each case. Six patients had a late dislocation, for whom the polyethylene liner was exchanged. Each acetabular component was well fixed and all femoral components showed signs of bone ingrowth. The mean rate of femoral head penetration was 0.10 mm/year (0.021 to 0.481). The probability of not developing femoral cortical hypertrophy and proximal osteopenia by 12 years was 80.2% (95% confidence interval, 72.7 to 87.6) and 77.5% (95% confidence interval, 69.7 to 85.2), respectively. Despite these good clinical results, further follow-up is needed to determine whether these prostheses will loosen with time.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 65 - 65
1 Mar 2009
Garcia-Rey E Garcia-Cimbrelo E Ortega-Chamarro J Cruz-Pardos A Sanchez J
Full Access

Introdution. Gamma sterilisation in air produces free radicals in the polyethylene (PE) with the result of degrading its mechanical properties, increasing wear and debris, and producing osteolysis and loosening. PE sterilized in the absence of air and high cross-linked polyethylene (HXLPE) have been used to avoid osteolysis and loosening. This prospective randomized study has assessed results in a series using two different poly-ethylenes associated with the same prosthetic design.

Methods: We assessed 45 Allofit cups with Sulene-PE liner (sterilized with nitrogen) and 45 Allofit cups with Durasul-PE liner (HXLPE), both associated with an Alloclassic stem (28-mm femoral head) (Zimmer). The minimum follow-up is 5 years and the mean follow-up 66.3 months. The linear femoral head penetration was estimated at 6 weeks, at 6 and 12 months and annually thereafter, using a software package employing the Dorr method, given the nonspherical cup shape.

Results All assessed hips had good clinical and radiographic results. There was no loosening of any prosthetic component. There were no radiolucent lines or osteolysis. Femoral head penetration in the early postoperative radiographs was 47.4% less in the Durasul group (0.09+0.03 mm) than the Selene-PE group (0.19+0.06 mm)(p< 0.0001). The mean yearly linear femoral head penetration was 20% lower in the Durasul group (0.008+0.008) than the Sulene-PE group (0.04+0.02)(p< 0.0001). Differences increase after the third year. Mean linear femoral head penetration at 5 years was 39.1% less in the Durasul group (p< 0.0001).

Conclusions: Although the digitized method used is not totally accurate and is used only for a general estimate, there is a significant reduction in yearly linear femoral head penetration with Durasul-PE. Longer-term results are needed to confirm that this polyethylene generates less osteolysis.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 112 - 113
1 Mar 2009
Ojeda-Thies C Moracia-Ochagavia I Rubio-Suarez J Alonso-Biarge J Garcia-Cimbrelo E
Full Access

Introduction: There are protocols on the management of polytrauma in obstetric patients. However, there is little information about osteo-articular injuries sustained in these patients. The object of this study is to review the management of these patients and to suggest a guideline.

Material and method: Inclusion criteria: Pregnant patients treated during the last 6 years, treated as inpatients in our center during pregnancy due to osteo-articular injuries.

Variables studied: Gestational age, mechanism of injury, fracture type, management, termination of pregnancy and sequelae.

Results: We treated 13 patients with 21 fractures in our center, with an incidenc of 2,13 fractures/10.000 births. The mechanism of injury was low degree trauma in 6 cases (60% 3rd trimester) and high-degree in 7 (83% 1st and 2nd trimester). There was a predominance of lower extremity fractures, especially tibia and fibula (7 cases) and pelvis (3 cases).

Gestational age was 1st trimester (3 cases), 2nd trimester (5 cases), 3rd trimester (5 cases). 10 women were treated surgically, 8 before finishing gestation. Gestation ended as and induced abortion (3 cases, 1 due to fetal death and 2 due to teratogenic risk), and birth (10 cases, all alive, 50% eutocic). Only 3 babies needed type II or type III neonatal reanimation.

CONCLUSIONS: Pregnant women can get injured by low-energy trauma, especially during the third trimester. Pregnancy does not necessarily compromise surgical management of fractures. We review diagnostic and therapeutic management strategies for these patients.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 88 - 88
1 Mar 2009
Garcia-Cimbrelo E Murcia-Mazon A Blanco-Pozo A Marti E
Full Access

Introduction. Alternative bearing surfaces to polyethylene have been introduced to avoid the appearance of osteolysis in THR. The aim of this study has been to perform prospective analysis of the data from a multi-center clinical trial for assessing the incidence of early alumina-specific-complications.

Material and Methods. We analysed 310 Cerafit cups associated with a Multicone-HA stem using alumina-on-alumina bearings implanted in four institutions from 1999 to 2003, with a mean follow-up of 4.7 years. Patients’ mean age was 52.8+13.4 years. Linear femoral head penetration was analysed using a software package.

Results. There were 4 revisions: 2 revisions due to dislocations resulting poor surgical technique (1 cup and 1 stem) and 2 revisions after a trauma (1cup and 1 stem). There was 1 alumina liner fracture 36 months after implant in a hip with a horizontal acetabular angle (35°) and a thin alumina liner (size 50/32). The other cases showed good clinical and radiographic results at the end of follow-up. The radiographic difference between the femoral head and cup centres at 6 weeks postsurgery was 2.48+0.60 mm, without changes in the course of the follow-up. The mean linear femoral head penetration was unreliable (0.00186+0.0032 mm/year) because it was below the mean error for the measurement system.

Conclusions. These data demonstrate that Cerafit Alumina-on-Alumina prostheses show excellent results after 5 years. Liner fractures are uncommon. Despite the blurred alumina images, the digitized method, although not totally accurate and used only for a general estimate, allows us to measure the approximate distance between the centre of the cup and the centre of the femoral head. Changes in linear femoral head penetration were not seen in any hip. Continued follow-up should determine if reduction in wear among the alumina-on alumina bearings results in less osteolysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 149 - 153
1 Feb 2008
García-Rey E García-Cimbrelo E Cruz-Pardos A Ortega-Chamarro J

Ultra-high-molecular-weight polyethylene sterilised in the absence of air and highly cross-linked polyethylene have been used to avoid osteolysis and loosening in total hip replacement. Our prospective randomised study has assessed the results using two different polyethylenes associated with the same prosthetic design. We assessed 45 Allofit acetabular components with a Sulene-polyethylene liner of conventional polyethylene gamma sterilised with nitrogen and 45 Allofit acetabular components with a Durasul-polyethylene liner sterilised in ethylene oxide, both matched with an Alloclassic stem with a 28 mm modular femoral head. The prostheses were implanted between May 1999 and December 2001. The mean follow-up was for 66.3 months (60 to 92). The linear penetration of the femoral head was estimated at 6 weeks, at 6 and 12 months and annually thereafter from standardised digitised radiographs using image-analysis software.

There was no loosening of any prosthetic component. There were no radiolucent lines or osteolysis. The mean rate of penetration calculated from regression analysis during the first five years was 38 μm/year (sd 2) for the Sulene group and 6 μm/year (sd 1) for the Durasul group (p = 0.00002). The rate of penetration of the Durasul group was 15.7% of that of the Sulene group.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 44 - 44
1 Mar 2006
García-Rey E Garcia-Cimbrelo E Cruz-Pardos A De La Cerda J
Full Access

Aim: We assessed prospectively clinical and radiographic results of two different polyethylenes (PE) associated with the same prosthetic design (Zimmer-Centerpulse).

Material and Methods: We assessed 56 Allofit cups with Sulene-PE liner (sterilized in nitrogen) and 45 with Durasul-PE liner (highly cross-linked) associated with an Alloclassic stem (28-mm femoral head) implanted between 1999–2002. The mean follow-up was 29.4 months for the Sulene-PE and 25.3 for Durasul-PE. The radiologic study according to Johnston et al. and the PE wear estimated according to a software package (AutoCAD R14), were analysed at 6 weeks (zero position), at 6 and 12 months and annually thereafter.

Results: There were 3 dislocations which were excluded from the follow-up study. There were no infections. All assessed hips had good clinical and radiographic results. There was no loosening of any prosthetic component. There were no radiolucent lines, osteolysis, cortical hypertrophy, or femoral osteopenia. The distances between the acetabular shell and the femoral head centres taken in the early postoperative radiographs (zero position or bedding-in) were 0.30+0.094 mm for the Sulene-PE group and 0.20+0.074 for the Durasul-PE (p=0.029). The mean wear related with the zero position was 0.1035+0.0686 and 0.0819+0.078 (p=0.108) respectively.

Conclusions: Despite the measurement error of PE wear being higher in the Allofit cup, a higher zero position (bedding-in) was found in the Sulene-PE group than in the Durasul-PE. Although the mean wear was higher in the Sulene-PE than in the Durasul-PE, with the number of hips available, differences were not significant after 3 years