Aims. Cephalomedullary nails (CMNs) are commonly used for the treatment of intertrochanteric hip fractures. Total hip arthroplasty (THA) may be used as a salvage procedure when fixation fails in these patients. The aim of this study was to analyze the complications of THA following failed intertrochanteric
Objectives. Fractures of the proximal femur are a common clinical problem, and a number of orthopaedic devices are available for the treatment of such fractures. The objective of this study was to assess the rotational stability, a common failure predictor, of three different rotational control design philosophies: a screw, a helical blade and a deployable crucifix. Methods. Devices were compared in terms of the mechanical work (W) required to rotate the implant by 6° in a bone substitute material. The substitute material used was Sawbones polyurethane foam of three different densities (0.08 g/cm. 3. , 0.16 g/cm. 3. and 0.24 g/cm. 3. ). Each torsion test comprised a steady ramp of 1°/minute up to an angular displacement of 10°. Results. The deployable crucifix design (X-Bolt), was more torsionally stable, compared to both the dynamic hip screw (DHS, p = 0.008) and helical blade (DHS Blade, p= 0.008) designs in bone substitute material representative of osteoporotic bone (0.16 g/cm. 3. polyurethane foam). In 0.08 g/cm. 3. density substrate, the crucifix design (X-Bolt) had a higher resistance to torsion than the screw (DHS, p = 0.008). There were no significant differences (p = 0.101) between the implants in 0.24 g/cm. 3. density bone substitute. Conclusions. Our findings indicate that the clinical standard proximal fracture fixator design, the screw (DHS), was the least effective at resisting torsional load, and a novel crucifix design (X-Bolt), was the most effective design in resisting torsional load in bone substitute material with density representative of osteoporotic bone. At other densities the torsional stability was also higher for the X-Bolt, although not consistently significant by statistical analysis. Cite this article: J. D. Gosiewski, T. P. Holsgrove, H. S. Gill. The efficacy of rotational control designs in promoting torsional stability of
A fluoroscopic based computer enhancement system was designed for accurate insertion of guide wires for
Aims. To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture. Methods. This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty). Results. Eight female (29%) and 20 male trainees (71%), mean age 29.4 years, performed 317 DHS operations and 243 hemiarthroplasties during ten months of follow-up. Primary analysis was a random effect model with surgeon-level fixed effects of patient condition, patient age, and surgeon experience, with a random intercept for surgeon. Under the intention-to-treat principle, for hemiarthroplasty there was better implant position in favour of cadaveric training, measured by leg length discrepancy ≤ 10 mm (odds ratio (OR) 4.08 (95% confidence interval (CI) 1.17 to 14.22); p = 0.027). There were significantly fewer postoperative blood transfusions required in patients undergoing hemiarthroplasty by cadaveric-trained compared to standard-trained surgeons (OR 6.00 (95% CI 1.83 to 19.69); p = 0.003). For DHS, there was no significant between-group difference in implant position as measured by tip-apex distance ≤ 25 mm (OR 6.47 (95% CI 0.97 to 43.05); p = 0.053). No between-group differences were observed for any secondary clinical outcomes. Conclusion. Trainees randomized to additional cadaveric training performed
Intra-operative Tip-Apex Distance (TAD) estimation optimises dynamic hip screw (DHS) placement during
Aim: To compare the acute haemoglobin level drop following
Internal fixation of pertrochanteric fractures is evolving as newer implants are being developed. Proximal Femoral Nail Antirotation (PFNA) is a recently introduced implant from AO/ASIF designed to compact the cancellous bone and may be particularly useful in unstable and osteoporotic hip fractures. This study is a single and independent centre experience of this implant used in management of acute hip fractures. 68 patients involving 68 PFNA nailing procedures done over a period of 2 years (2007–09) were included in the study. Average follow-up period of patients was 1 year. AO classification for trochanteric fractures was used to classify all the fractures. Radiological parameters including tip-apex distance and neck shaft angle measurement were assessed.Introduction
Methods
Majority of osteoporosis related fractures are treated surgically using metallic fixation devices. Anchorage of fixation devices is sometimes challenging due to poor osteoporotic bone quality that can lead to failure of the fracture fixation. Using a rat osteoporosis model, we employed neutron tomography and histology to study the biological effects of implant augmentation using an isothermally setting calcium sulphate/hydroxyapatite (CaS/HA) biomaterial with synthetic HA particles as recruiting moiety for systemically administered bisphosphonates. Using an osteoporotic sawbones model, we then provide a standardized method for the delivery of the CaS/HA biomaterial at the bone-implant interface for improved mechanical anchorage of a lag-screw commonly used for
Solid organ transplant (SOT) recipients present an increased medical risk; however, few studies analyze the outcomes of these patients undergoing hip fracture surgery. This study aimes to determine the incidence of hip fracture in SOT patients and to compare the outcomes of SOT patients with matched non-SOT controls after
Appropriate surgical management of hip fractures has major clinical and economic consequences. Recently IMN use has increased compared to SHS constructs, despite no clear evidence demonstrating superiority of outcome. We therefore set out to provide further evidence about the clinical and economic implications of implant choice when considering
Thru purpose of this study was to evaluate the clinical outcomes of a consecutive series of conversion total hip arthroplasty (cTHA) following previous hip fractures. A retrospective chart review of patients who underwent cTHAs from 2008–2017 at an urban academic teaching institution was performed. Eighty-eight patients were included in this study. The mean age at the cTHA was 66 years (range 27 to 89). 67% of the patients wre women. The mean BMI was 28 kg/m. 2. (range 17 to 41). The mean Charlson Comorbidity Index was 3 (range 0 to 9). The mean follow-up was 49 months (range 24 to 131). The mean duration from the
Debate continues about the best treatment for patients over 65 years with non-displaced subcapital
Intracapsular neck of femur fractures may be treated with fixation or arthroplasty, depending on fracture characteristics and patient factors. Two common methods of fixation are the sliding hip screw, with or without a de-rotation screw, and cannulated screws. Each has its merits, and to date there is controversy around which method is superior, with either method thought to risk avascular necrosis of the femoral head (AVN) rates in the region of 10–20%. Fixation with cannulated screws may be performed in various ways, with current paucity of evidence to show an optimum technique. There are a multitude of factors which are likely to affect patient outcomes: technique, screw configuration, fracture characteristics and patient factors. We present a retrospective case series analysis of 65 patients who underwent cannulated screw fixation of a hip fracture. Electronic operative records were searched from July 2014 until July 2019 for all patients with a neck of femur fracture fixed with cannulated screws: 68 were found. Three patients were excluded on the basis of them having a pathological fracture secondary to malignancy, cases were followed up for 2 years post-operatively. Electronic patient records and X-rays were reviewed for all included patients. All X-rays were examined by each team member twice, with a time interval of two weeks to improve inter-observer reliability. 65 patients were included with 2:1 female to male ratio and average age of 72 years. 36 patients sustained displaced fractures and 29 undisplaced. Ten patients sustained a high-energy injury, none of which developed AVN. Average time to surgery was 40 hours and 57 patients mobilised on day one post-operatively. All cases used either 7 or 7.3mm partially threaded screws in the following configurations: 2 in triangle apex superior, 39 triangle apex inferior, 22 rhomboid and 2 other, with 9 cases using washers. All reductions were performed closed. Five (8%) of our patients were lost to follow-up as they moved out of area, 48 (74%) had no surgical complications, seven (11%) had mild complications, three (5%) moderate and two (3%) developed AVN. Both of these sustained displaced fractures with low mechanism of injury, were female, ASA 2 and both ex-smokers. One received three screws in apex inferior configuration and one rhomboid, neither fixed with washers. Our AVN rate following intracapsular
The aim of this study was to examine perioperative blood transfusion practice, and associations with clinical outcomes, in a national cohort of hip fracture patients. A retrospective cohort study was undertaken using linked data from the Scottish Hip Fracture Audit and the Scottish National Blood Transfusion Service between May 2016 and December 2020. All patients aged ≥ 50 years admitted to a Scottish hospital with a hip fracture were included. Assessment of the factors independently associated with red blood cell transfusion (RBCT) during admission was performed, alongside determination of the association between RBCT and hip fracture outcomes.Aims
Methods
To identify variables independently associated with same-day discharge (SDD) of patients following revision total knee arthroplasty (rTKA) and to develop machine learning algorithms to predict suitable candidates for outpatient rTKA. Data were obtained from the American College of Surgeons National Quality Improvement Programme (ACS-NSQIP) database from the years 2018 to 2020. Patients with elective, unilateral rTKA procedures and a total hospital length of stay between zero and four days were included. Demographic, preoperative, and intraoperative variables were analyzed. A multivariable logistic regression (MLR) model and various machine learning techniques were compared using area under the curve (AUC), calibration, and decision curve analysis. Important and significant variables were identified from the models.Aims
Methods
Total hip arthroplasty (THA) is considered the preferred treatment for displaced proximal femoral neck fractures. However, in many countries this option is economically unviable. To improve outcomes in financially disadvantaged populations, we studied the technique of concomitant valgus hip osteotomy and operative fixation (VOOF). This prospective serial study compares two treatment groups: VOOF versus operative fixation alone with cannulated compression screws (CCSs). In the first series, 98 hip fixation procedures were performed using CCS. After fluoroscopic reduction of the fracture, three CCSs were placed. In the second series, 105 VOOF procedures were performed using a closing wedge intertrochanteric osteotomy with a compression lag screw and lateral femoral plate. The alignment goal was to create a modified Pauwel’s fracture angle of 30°. After fluoroscopic reduction of fracture, lag screw was placed to achieve the calculated correction angle, followed by inter-trochanteric osteotomy and placement of barrel plate. Patients were followed for a minimum of two years.Aims
Methods
Ankle fracture fixation is commonly performed by junior trainees. Simulation training using cadavers may shorten the learning curve and result in a technically superior surgical performance. We undertook a preliminary, pragmatic, single-blinded, multicentre, randomized controlled trial of cadaveric simulation versus standard training. Primary outcome was fracture reduction on postoperative radiographs.Aims
Methods
This study aimed to describe practice variation in the use of total hip arthroplasty (THA) for older patients with femoral neck fracture and to determine the association between patient, surgeon, and institution factors and treatment with THA. We performed a cross-sectional analysis of 49,597 patients aged 60 years and older from Ontario, Canada, who underwent hemiarthroplasty or THA for femoral neck fracture between 2002 and 2017. This population-based study used routinely collected healthcare databases linked through ICES (formerly known as the Institute for Clinical Evaluative Sciences). Multilevel logistic regression modelling was used to quantify the association between patient, surgeon, and institution-level variables and whether patients were treated with THA. Variance partition coefficient and median odds ratios were used to estimate the variation attributable to higher-level variables and the magnitude of effect of higher-level variables, respectively.Aims
Methods