Advertisement for orthosearch.org.uk
Results 1 - 20 of 880
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 746 - 754
1 Apr 2021
Schnetzke M El Barbari J Schüler S Swartman B Keil H Vetter S Gruetzner PA Franke J

Aims. Complex joint fractures of the lower extremity are often accompanied by soft-tissue swelling and are associated with prolonged hospitalization and soft-tissue complications. The aim of the study was to evaluate the effect of vascular impulse technology (VIT) on soft-tissue conditioning in comparison with conventional elevation. Methods. A total of 100 patients were included in this prospective, randomized, controlled monocentre study allocated to the three subgroups of dislocated ankle fracture (n = 40), pilon fracture (n = 20), and intra-articular calcaneal fracture (n = 40). Patients were randomized to the two study groups in a 1:1 ratio. The effectiveness of VIT (intervention) compared with elevation (control) was analyzed separately for the whole study population and for the three subgroups. The primary endpoint was the time from admission until operability (in days). Results. The mean length of time until operability was 8.2 days (SD 3.0) in the intervention group and 10.2 days (SD 3.7) in the control group across all three fractures groups combined (p = 0.004). An analysis of the subgroups revealed that a significant reduction in the time to operability was achieved in two of the three: with 8.6 days (SD 2.2) versus 10.6 days (SD 3.6) in ankle fractures (p = 0.043), 9.8 days (SD 4.1) versus 12.5 days (SD 5.1) in pilon fractures (p = 0.205), and 7.0 days (SD 2.6) versus 8.4 days (SD 1.5) in calcaneal fractures (p = 0.043). A lower length of stay (p = 0.007), a reduction in pain (p. preop. = 0.05; p. discharge. < 0.001) and need for narcotics (p. preop. = 0.064; p. postop. = 0.072), an increased reduction in swelling (p < 0.001), and a lower revision rate (p = 0.044) could also be seen, and a trend towards fewer complications (p = 0.216) became apparent. Conclusion. Compared with elevation, VIT results in a significant reduction in the time to achieve operability in complex joint fractures of the lower limb. Cite this article: Bone Joint J 2021;103-B(4):746–754


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1303 - 1313
1 Dec 2023
Trammell AP Hao KA Hones KM Wright JO Wright TW Vasilopoulos T Schoch BS King JJ

Aims. Both anatomical and reverse total shoulder arthroplasty (aTSA and rTSA) provide functional improvements. A reported benefit of aTSA is better range of motion (ROM). However, it is not clear which procedure provides better outcomes in patients with limited foward elevation (FE). The aim of this study was to compare the outcome of aTSA and rTSA in patients with glenohumeral osteoarthritis (OA), an intact rotator cuff, and limited FE. Methods. This was a retrospective review of a single institution’s prospectively collected shoulder arthroplasty database for TSAs undertaken between 2007 and 2020. A total of 344 aTSAs and 163 rTSAs, which were performed in patients with OA and an intact rotator cuff with a minimum follow-up of two years, were included. Using the definition of preoperative stiffness as passive FE ≤ 105°, three cohorts were matched 1:1 by age, sex, and follow-up: stiff aTSAs (85) to non-stiff aTSAs (85); stiff rTSAs (74) to non-stiff rTSAs (74); and stiff rTSAs (64) to stiff aTSAs (64). We the compared ROMs, outcome scores, and complication and revision rates. Results. Compared with non-stiff aTSAs, stiff aTSAs had poorer passive FE and active external rotation (ER), whereas there were no significant postoperative differences between stiff rTSAs and non-stiff rTSAs. There were no significant differences in preoperative function when comparing stiff aTSAs with stiff rTSAs. However, stiff rTSAs had significantly greater postoperative active and passive FE (p = 0.001 and 0.004, respectively), and active abduction (p = 0.001) compared with stiff aTSAs. The outcome scores were significantly more favourable in stiff rTSAs for the Shoulder Pain and Disability Index, Simple Shoulder Test, American Shoulder and Elbow Surgeons score, University of California, Los Angeles score, and the Constant score, compared with stiff aTSAs. When comparing the proportion of stiff aTSAs versus stiff rTSAs that exceeded the minimal clinically important difference and substantial clinical benefit, stiff rTSAs achieved both at greater rates for all measurements except active ER. The complication rate did not significantly differ between stiff aTSAs and stiff rTSAs, but there was a significantly higher rate of revision surgery in stiff aTSAs (p = 0.007). Conclusion. Postoperative overhead ROM, outcome scores, and rates of revision surgery favour the use of a rTSA rather than aTSA in patients with glenohumeral OA, an intact rotator cuff and limited FE, with similar rotational ROM in these two groups. Cite this article: Bone Joint J 2023;105-B(12):1303–1313


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 843 - 845
1 Sep 1990
Browne A Hoffmeyer P Tanaka S An K Morrey B

We studied the position and rotational changes associated with elevation of the glenohumeral joint, using a three-dimensional magnetic-field tracking system on nine fresh cadaveric shoulders. The plane of maximal arm elevation was shown to occur 23 degrees anterior to the plane of the scapula. Elevation in any plane anterior to the scapula required external humeral rotation, and maximal elevation was associated with approximately 35 degrees of external humeral rotation. Conversely, internal rotation was necessary for increased elevation posterior to the plane of the scapula. The observed effects of this rotation were to clear the humeral tuberosity from abutting beneath the acromion and to relax the inferior capsular ligamentous constraints. Measurement of the obligatory humeral rotation required for maximal elevation helps to explain the relationship of the limited elevation seen in adhesive capsulitis and after operations which limit external rotation


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 519 - 525
1 Apr 2016
Lees DA Penny JB Baker P

Aims. The aim of this study was to compare the pain caused by the application of a tourniquet after exsanguination of the upper limb with that occurring after simple elevation. . Patients and Methods. We used 26 healthy volunteers (52 arms), each of whom acted as their own matched control. The primary outcome measure was the total pain experienced by each volunteer while the tourniquet was inflated for 20 minutes. This was calculated as the area under the pain curve for each individual subject. Secondary outcomes were pain at each time point; the total pain experienced during the recovery phase; the ability to tolerate the tourniquet and the time for full recovery after deflation of the tourniquet. . Results. There was a significant difference in the area under the pain curves in favour of exsanguination (mean difference 8.4; 95% confidence interval (CI) 3.0 to 13.7, p = 0.004). There was no difference between the dominant and non-dominant arms (mean difference -0.2; 95% CI -23.2 to 22.8, p = 0.99). The area under both recovery curves were similar (mean difference 0.7; 95% CI -6.0 to 4.6, p = 0.78). There was no statistical difference in recovery time, the actual mean difference being 30 seconds longer in the elevation group (p = 0.06). Conclusion. Many orthopaedic and plastic surgery procedures are done under local anaesthetic or regional block where a bloodless field and a motionless patient are essential. Optimising patient comfort during surgery with the tourniquet inflated is thus a priority. This study is useful in that it compares two common methods of preparation of the upper limb prior to tourniquet inflation and which have not previously been compared in this context. Following on the results of this study, we can confidently conclude that exsanguinating the upper limb before inflating a tourniquet is more comfortable than simply elevating the arm for patients undergoing a procedure under local or regional block, both during the procedure and in the recovery phase. . Take home message: Exsanguination rather than elevation is recommended in order to minimise patient discomfort and optimise the surgical field. Cite this article: Bone Joint J 2016;98-B:519–25


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 41 - 41
1 Oct 2012
Song E Seon J Kang K Park C Yim J
Full Access

The elevation of the joint line is considered a possible cause of mid-flexion instability in total knee arthroplasty (TKA). The authors evaluated the effects of joint line change on mid-flexion stability in cruciate retaining TKA. Seventy-nine knees treated by cruciate retaining TKA using a modified balanced gap technique were included in this prospective study. After prosthesis insertion, valgus and varus stabilities were measured under valgus and varus stress using a navigation system at 0, 30, 60 and 90° of knee flexion. Changes of joint lines were measured preoperatively and postoperatively and compared. The knees were allocated to a “No change group (≤4mm, 62 patients)” or to an “Elevation group (>4mm, 17 patients)”. Medio-lateral stabilities (defined as the sums of valgus and varus stabilities measured intra-operatively) were compared in the two groups. The mean joint line elevation was 4.6mm in the no change group and 1.7mm in the elevation group. Mean medio-lateral stability at 30° of knee flexion was 4.8±2.3 mm in the no change group and 6.3±2.7 mm in the elevation group, and these values were significantly different (p = 0.02). However, no significant differences in medio-lateral stability were observed at other flexion angles (p>0.05). Knees with a < 5mm joint line elevation provide better mid-flexion stability after TKA. The results of this study suggest that a < 5mm elevation in joint line laxity is acceptable for cruciate retaining TKA


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 325 - 325
1 May 2006
Maroñas C Gutiérrez C Bas T Hernandez-Ayuso E
Full Access

Introduction: Most hospitals that treat patients with Pectus Excavatum use the pectus bar designed by D. Nuss. In essence, chest elevation is achieved by using a previously moulded steel bar. It is relatively safe since the introduction of thoracoscopy, although there is a risk of injury to the heart. Our group has attempted to diminish this risk by means of sternal traction using a clamp specially designed for use with a thorascope anchored in the cancellous tissue of the sternum. Materials and methods: We used a tailored clamp in three consecutive patients aged 8, 12 and 15 with Pectus Excavatum Haller index > 7. Procedure: Thorascopy was performed for a good assessment of the rib cage. Under direct vision, we inserted one arm of the clamp underneath the sternum at the deepest point of the defect about 5 cm to the right of the midline. With the other arm of the clamp we grasped the anterior side of the sternum percutaneously. When the clamp was closed, we could raise the sternum to increase the mediastinal space. Results: The sternal elevation was satisfactory. Using thorascopy during the procedure enhanced safety and the additional time was a few minutes. Conclusions: Correction of pectus excavatum is indicated for aesthetic purposes in many patients and the absence of severe complications is a goal. The sternal elevation described here (although it is only a preliminary study) is fast, economical and appears to make the Nuss procedure safer


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 93 - 93
1 Mar 2017
Pourzal R Cip J Rad E Laurent M Jacobs J Wimmer M
Full Access

Introduction. Wear debris from polyethylene tibial inserts has been associated with limited longevity of total knee replacements (TKRs). While material factors were studied extensively and considerable progress has been made, there is little knowledge about surgical factors, particularly on how the wear rate is related to implant positioning. It was the purpose of this study to determine the combined effect of patient and implant positioning factors on the volumetric wear rate of TKRs. Our hypothesis was that implant alignment has a significant impact on the wear rate when controlled for other patient factors. Methods. This study included 59 tibial inserts of a cruciate retaining TKR design (Nexgen, Zimmer Inc.). The patients' age, sex, weight, height, and implant size were obtained. All implants were scanned with a coordinate measuring machine. Volumetric wear was determined using an autonomous mathematical reconstruction method (Figure 1). Radiographs were used to determine the anatomic lateral distal femoral angle (aLDFA), anatomic medial proximal tibial angle (aMPTA), femoral tilt angle (FTA) and posterior tibial slope (PTS). Also, the patella position was assessed using the Blackburne-Peel Index (BPI) and the Insall-Salvati Ratio (Figure 2). General linear modeling (SPSS) was conducted in order to determine the most significant patient and implant positioning factors on wear rate. Results. After adjustment for creep, the mean volumetric wear rate was 11.6 mm. 3. /yr (Figure 2). According to the linear regression model wear increased with younger age (p=0.0014) and male sex (p<0.001). The wear rate was independent of patient weight (p=0.17). From the multiple positioning factors only BPI and tibial slope were significant and inversely correlated with wear (p=0.009 and 0.026, respectively). The average ISR was normal before and after surgery, whereas the BPI was only in the normal range prior to surgery, and dropped postop into pseudo-baja (p<0.001, Figure 3). Discussion. The effect of male sex on wear volume can partially be explained by a larger average implant size; however, other unknown confounding factors may play a role too. The effect of younger age is likely related to higher patient activity. Based on previous gait analysis, we speculate that increasing tibial slope results in larger AP translations of the knee joint and thus more wear. Interestingly, BPI remained a highly significant factor when controlled for all other factors. The average BPI clearly dropped post-operatively, whereas the average ISR did not, indicating that not true patella baja, but a joint line elevation occurred due to the reconstruction. Joint line elevation may affect the quadriceps mechanism leading to higher contact forces and subsequent higher wear. Post-operative joint line elevation can be explained by the intention to keep bone loss at a minimum, while using thick polyethylene inserts. Further studies are needed to determine the trade-offs between bone conservation and reduction of wear rate. However, this study has revealed the importance of surgical factors regarding polyethylene wear reduction in TKR. Acknowledgements. This study was funded by NIH grant R01AR059843. For figures/tables, please contact authors directly.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 12 - 12
1 Jan 2003
Gibbons C Reed M Partington P
Full Access

The aim of this study was to establish the ability of an invasive fibre-optic probe to measure intra-muscular pH, pCO. 2. , pO. 2. , HCO. 3. -. −. , ambient temperature, base excess and O. 2. saturation. The secondary aim was to determine the effect of elevation of the limb on these parameters. Fibre-optic probes were introduced into the anterior compartment muscle of the leg in five volunteers via 16G cannulae. After equilibration the limb was monitored for 11min with the volunteer supine on an examination couch. The limb was elevated to 22cm (Braun frame) and then 44cm for the same time. Subsequently the leg was returned to 22cm and supine. All volunteers followed this set protocol. Continuous recording of all indices was made throughout. Data was stored to a personal computer for analysis. Similar trends were observed across all subjects for all parameters. The mean pO. 2. when lying flat was 27mmHg (S.D.7.4). Elevation to 22cm increased muscle pO. 2. to 33 mmHg (S.D. 5.8). Further elevation to 44 cm resulted in a reduction in muscle pO. 2. to a level below that measured when supine. When the limb was returned to 22cm the pO2 trend reversed, the level improving. Returning to the supine position the pO. 2. returned to the level seen at the start of monitoring. This novel probe gives reproducible measures of pH, pCO. 2. , pO. 2. , HCO. 3. −. , ambient temperature, base excess and O. 2. saturation. Results indicate that elevation to 22cm improves muscle oxygenation; a height of 44cm seems detrimental. This technique may be applicable in surveillance for compartment syndromes and muscle ischaemia


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 50 - 50
1 Dec 2013
Dong N Heffernan C Nevelos J Ries M
Full Access

Introduction:. Acetabular revision Jumbo cups are used in revision hip surgeries to allow for large bone to implant contact and stability. However, jumbo cups may also result in hip center elevation and instability. They may also protrude through anterior wall leading to ilopsoas tendinitis. Methods:. The study was conducted using two methods:. Computer simulation study. 265 pelvic CT scans consisting of 158 males and 107 females were converted to virtual 3-dimensional bones. The average native acetabular diameter was 52.0 mm, SD = 4.0 mm (males in 52.4 mm, SD = 2.8 mm and 46.4 mm, SD = 2.6 mm in females). Images were analyzed by custom CT analytical software (SOMA™ V.3.2). 1. and over-sized reaming was simulated. Four distinct points, located in and around the acetabular margins, were used to determine the reamer sphere. Points 1, 2, 3 were located at the inferior and inferior-medial acetabular margins, and Point 4 was located superiorly and posteriorly in the acetabulum to simulate a bony defect in this location, Point 4 was placed at 10%, 20%, 30%, 40%, 50% and 60% of the distance from the superior – posterior margin of the acetabular rim to the sciatic notch to simulate bony defects of increasing size. (Figure 1). Radiographical study. Retrospective chart review of patient records for all cementless acetabular revisions utilizing jumbo cups between January 1, 1998 and March 30, 2012 at UCFS (98 patients with 57 men, 41 women). Jumbo cups: ≥66 mm in males; <62 mm in females. Reaming was directed inferiorly to the level of the obturator foramen to place the inferior edge of the jumbo cup at the inferior acetabulum. To determine the vertical position of the hip center, a circle was first made around both the jumbo and the contralateral acetabular surfaces using Phillips iSite PACS software. The center of this circle was assumed to correspond to the “hip center”. The height of the hip center was estimated by measuring the height of a perpendicular line arising from the interteardrop line (TL) and ending at the hip center. Results:. The computer simulation and radiographic analysis deomonstrated similar results. The computer simulation predicted that the hip center shifted superiorly and anteriorly as the reamer size increased. The hip center shifted 0.27 mm superiorly and 0.02 mm anteriorly for every millimeter in diameter increased for the reaming. (Figure 2) Anterior column bone removal was increased 0.86 mm for every 1 mm of reamer size increase. (Figure 3). Results of radiographical study is shown in Table bellow:. Discussion:. Use of a jumbo cup in revision THA results in elevation of the hip center. Therefore a longer femoral head may be needed to compensate for hip center elevation when a jumbo cup is used. Reaming for a jumbo cup can also result in loss of anterior bone stock and protrusion of the cup anteriorly which may cause iliopsoas tendonitis


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 9 - 9
1 Jun 2017
Wright J Calder P
Full Access

Background. Severe infantile Blount's disease can result in a multiplanar deformity of the proximal tibia with both intra-articular and metaphyseal components. Correction can represent a significant surgical challenge. We describe our results using the Taylor spatial frame for acute tibial hemiplateau elevation combined with gradual metaphyseal correction in patients with severe infantile blounts with an associated physeal bony bar. Methods. Eight patients (10 knees) underwent tibial hemiplateau elevation and metaphyseal correction with use of the Taylor Spatial Frame between 2012–2016. We undertook a retrospective case note and radiographic review of all patients to assess clinical and radiographic outcomes. Mean age at the time of surgery of was 11.7 years and mean length of follow up was 16.8 months. Results. At time of latest follow up all patients reported no hip, knee or ankle pain. All knees were clinically stable without lateral thrust during gait. Improvement in radiographic parameters was seen in all patients. The mean tibiofemoral angle improved from −28.3 to 5.9 degrees post operatively. The angle between femoral condyles and the tibial shaft improved from a mean of 56.3 degrees to 90.3 degrees. The joint depression angle was also seen to improve from mean 47.4 degrees to 9.8 degrees. No significant complications were seen. Conclusion. This technique has been shown to be an effective method of correction of the complex deformity encountered in severe infantile Blount's disease. Use of the Taylor spatial frame may provide certain advantages in comparison to previously described approaches. Level of Evidence: Level IV (Case Series)


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 100 - 100
1 Sep 2012
Labey L Chevalier Y Fukagawa S Innocenti B Okon T Bellemans J Kowalczewski J
Full Access

Introduction. Optimal knee joint function obviously requires a delicate balance between the osseous anatomy and the surrounding soft tissues, which is distorted in the case of joint line elevation (JLE). Although several studies have found no correlation between JLE and outcome, others have linked JLE to inferior results. The purpose of this in vitro investigation was to evaluate the effect of JLE on tibiofemoral kinematics and collateral ligament strains. Materials and Methods. Six cadaver knees were equipped with reflective markers on femur and tibia and CT scans were made. A total knee arthroplasty (TKA) was performed preserving the native joint level. The knees were then tested in passive flexion-extension and squatting in a knee kinematics simulator while marker positions were recorded with an optical system. During squatting quadriceps forces were measured as well as tibio-femoral contact pressures. Finally, a revision TKA was performed with JLE by 4 mm. The femoral component was downsized and a thicker insert was used. The knees were again tested as before. Based on the bony landmarks identified in the CT scans and the measured trajectories of the markers, relative tibiofemoral kinematics could be calculated as well as distance changes between insertions of the collateral ligaments. Statistical tests were carried out to detect significant differences in kinematic patterns, ligaments elongation, tibiofemoral contact pressures and quadriceps forces between the primary TKA and after JLE. Results. Tibiofemoral kinematics are shown in Figure 1. For both passive flexion and squatting, tibial external rotation and adduction were similar before and after JLE. In passive flexion, JLE decreased the posterior translation of the femoral medial and lateral condyle centres, especially beyond 40 degrees of flexion. A slight 5% anterior shift of both centres was noted after JLE during squatting, but this was not significant. Strains in the collateral ligaments are shown in Figure 2. The collateral ligament lengths remained constant during passive flexion and were unaffected by elevation of the joint line. During squatting, the sMCL stretched with flexion after primary TKA and this behaviour stayed constant when the joint line was elevated. The LCL showed a similar loosening trend in both TKA configurations. Also tibiofemoral joint kinetics were not affected by JLE: quadriceps force and contact pressures all remained essentially unchanged during squatting before and after JLE. Discussion and conclusion. Although clinical observations have indicated that JLE is associated with inferior clinical results, the effects of JLE on knee biomechanics which might explain these outcomes remain relatively unknown. In this study, we specifically evaluated those effects on tibiofemoral kinematics and kinetics, as well as elongation of the collateral ligaments. As our current study did not detect any effect of JLE in tibiofemoral kinematics, kinetics, and strains of collateral ligaments in revision TKA, it is possible that these effects may be limited to or triggered at the patello-femoral joint, and more significant with higher joint line elevations than the 4-mm level tested in the current study. This hypothesis needs to be further investigated in future in-vitro and in-vivo studies


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 3 | Pages 395 - 408
1 Aug 1972
Cavendish ME

1. One hundred cases of congenital elevation of the scapula are reviewed; thirty-four were treated by operation. 2. A method of grading of appearance is suggested to assist in selecting cases for operation. 3. In very mild cases operation does not confer worthwhile benefit. 4. Very severely affected patients cannot be made to look normal. 5. The appearance often deteriorates during a period of rapid growth of the neck, making continued observation and reassessment essential. 6. The primary aim of treatment is to improve appearance; improvement in function is uncertain. 7. Excision of the supero-medial part of the scapula, and of the omo-vertebral bone when present, is recommended in most cases requiring operation. It is safe and simple, with little risk of loss of function and with simple after-treatment


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_16 | Pages 7 - 7
1 Oct 2014
Ohl X Lagacé P Billuart F Hagemeister N Gagey O Skalli W
Full Access

Accurate and reproducible measurement of three-dimensional shoulder kinematics would contribute to better understanding shoulder mechanics, and therefore to better diagnosing and treating shoulder pathologies. Current techniques of 3D kinematics analysis use external markers (acromial cluster or scapula locator) or medical imaging (MRI or CT-Scan). However those methods present some drawbacks such as skin movements for external markers or cost and irradiation for imaging techniques. The EOS low dose biplanar X-Rays system can be used to track the scapula, humerus and thorax for different arm elevation positions. The aim of this study is to propose a novel method to study scapulo-thoracic kinematics from biplanar X-rays and to assess its reliability during abduction in the scapular plane. This study is based on the EOS™ system (EOS Imaging, Paris, France), which allows acquisition of 2 calibrated, low dose, orthogonal radiographs with the subject standing at 30 to 40° angle of coronal rotation to the plane of one of the X-ray beams, in order to limit superimposition with the ribcage and spine. Seven abduction positions in the scapular plane were maintained by the subjects for 10 seconds, during X-ray acquisition. Between two positions, the subjects returned at rest position. Arm elevations were approximately 0, 10, 20, 30, 60, 90 and 150° (position 1 to 7). Six subjects were enrolled to perform a reproducibility study based on the 3D reconstructions of 2 experienced observers three times each. For each subject, a personalised 3D reconstruction of the scapula was created. The observer digitises clearly visible anatomical landmarks on both stereoradiographs for each arm position. These landmarks are used to make a first adjustment of a parameterised 3D model of the scapula. This provides a pre-personalised model of the subject's scapula which is then rigidly registered on each pair of X-rays until its retroprojection fits best on the contours that are visible on the X-rays. The thorax coordinate system (CS) was built following the ISB (International Society of Biomechanics) recommendations. The CS associated to the scapula was a glenoid centred CS based on the ellipse which fit on the glenoid rim on the 3D model of scapula. Scapular CS orientation and translation in the thorax CS was calculated following a Y,X,Z angle sequence for each position. Each 3D reconstruction of the scapula was performed in approximately 30 minutes. The most reproducible rotation was upward/downward rotation (along X axis) with a 95% confidence interval (95% CI) from 2.71° to 3.61°. Internal/external rotation and anterior/posterior tilting were comprised respectively between 5.18° to 8.01° and 5.50° to 7.23° (CI 95%). The most reproducible translation was superior-inferior translation (along Y axis) with a 95% CI from 1.22mm to 2.46mm. Translation along X axis (antero-posterior) and Z axis (medio-lateral) were comprised respectively between 2.49mm to 4.26mm and 2.47mm to 3.30mm (CI 95%). We presented a new technique for 3D functional quantitative analysis of the scapulo-thoracic joint. This technique can be used with confidence; uncertainty of the measures seems acceptable compared to the literature. Main advantages of this technique are the very low dose irradiation compared to the CT-Scan and the possibility to study arm elevation above 120°


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 160 - 160
1 Feb 2003
Jones S Hosalkar H Hill R Hartley J
Full Access

We present the results of treatment for relapsed infantile Blounts disease using a technique of hemiplateau elevation with the Ilizarov frame. 7 patients with a mean age of 10 years 6 months were reviewed at 30 months following hemiplateau elevation with/without ipsilateral tibial lengthening. Preoperatively clinical photographs, long leg standing radiographs and 3D computed tomography images were acquired. The patients were evaluated clinically (presence of knee pain, range of knee motion, knee stability and leg length discrepancy) and radiologically. Schoeneckers objective assessment was undertaken. The results were analysed statistically. Clinically all the patients improved significantly. No patient had knee pain and the range of knee motion was from 0° to more than 100° of knee flexion. The radiological results and Schoeneckers grading are depicted below. The improvement in radiological measurements were statistically significant. Pin site infection was present in all but settled with antibiotics. The results of hemiplateau elevation for relapsed infantile Blounts disease are encouraging


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 201 - 201
1 Dec 2013
Watanabe H Hachiya Y Murata H Muramatsu K Taniguchi S Kondo M Tanaka K
Full Access

Introduction. Higher concentrations of metal ion levels after Metal-on-metal (MoM) THA are a cause for concern. Elevated cobalt (Co) and chromium (Cr) ion levels in the blood indicate metal wear, and may predict secondary soft-tissue damage (adverse reaction to metal debris; ARMD). Although, it is well known that concentrations of metal ion levels are elevated in the short term after MoM, the long-term consequences in ion concentration and risk factors for increased ion levels are not clarified. We sequentially investigated the postoperative Co and Cr ion levels after MoM THA and the relationship between the metal ion levels and several risk factors. Materials and Methods. We reviewed the data on one hundred and eighty six patients of two hundred ninety one MoM THA cases. The one hundred eighty six patients were measured at least three times after a MoM THA surgery over a five year (2005–2010) period in our institution. Serum cobalt and chromium levels were measured by inductor coupled plasma – mass spectrometry at several times in follow-up period, (measured at the preoperative period, the third month, the sixth month, the first year, the second year, and the fourth year after MoM THA). Furthermore, we investigated the correlation between the metal ion levels and various factors which might influence the release of metal ions, such as Body mass index (BMI), renal function, femoral head size, unilateral or bilateral THA, the cup position, and postoperative activity. The renal function was evaluated by measuring estimated glomerular filtration ratio (GFR) at preoperative examination. A postoperative activity was assessed with a pedometer measurement counting number of steps a day. A cup position was evaluated by lateral inclination measured by X-ray or computed tomography. Results. Average serum Co and Cr concentrations in preoperative period were 0.69 and 0.05 mg/ ml, respectively. Postoperative serum Co and Cr ion levels were significantly increased compared with preoperative value throughout the postoperative period. There was no significant correlation with regards to BMI, renal function, femoral head size tothe metal ion level measurement. In bilateral THA cases, Co and Cr ion concentrations were significantly increased compared with unilateral THA cases. In addition, in cases that its cup inclination was more than 50 degrees, Co and Cr ion concentration were significantly increased compared with cases less than 50 degrees in the first year after surgery. There was a trend for higher metal ion levels in the group of patients who walked more than 7000 steps a day, but this did not reach statistical significance. Conclusion. Metal ion concentrations of almost patients were increased after MoM THA surgery. Side effects related to elevation of serum Co or Cr concentration were currently not identified and overall clinical results were good. However, Longer follow-up would be necessary if the patients have overlapping risk factors, because those patients may experience elevation of the level in postoperative late stage


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 565 - 571
1 May 2003
Jones S Hosalkar HS Hill RA Hartley J

We have treated seven children with relapsed infantile Blount’s disease by elevation of the hemiplateau using the Ilizarov frame. Three boys and four girls with a mean age of 10.5 years were reviewed at a mean of 29 months after surgery. All had improved considerably and were pleased with the results. The improvements in radiological measurements were statistically significant (p < 0.001). Three-dimensional CT reconstruction was useful for planning surgery. There were no major complications. The advantages of this technique are that in addition to elevation of the hemiplateau, rotational deformities and limb-length discrepancies may be addressed


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 1 | Pages 59 - 63
1 Feb 1979
Banniza von Bazan U

Of forty-six patients with congenital elevation of the scapula, diastematomyelia was confirmed in four and was probably present in five others. Possible reasons for the previously unsuspected association are presented


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 220 - 226
1 Feb 2006
Krkovič M Kordaš M Tonin M Bošnjak R

Ulnar nerve function, during and after open reduction and internal fixation of fractures of the distal humerus with subperiosteal elevation of the nerve, was assessed by intra-operative neurophysiological monitoring. Intermittent recording of the compound muscle action potentials was taken from the hypothenar muscles in 18 neurologically asymptomatic patients. The mean amplitude of the compound muscle action potential after surgery was 98.1% (. sd. 17.6; −37% to +25%). The amplitude improved in six patients following surgery. Despite unremarkable recordings one patient had progressive paresis. Motor impairment is unlikely if the compound muscle action potential is continuously preserved and not reduced by more than 40% at the end of surgery. Temporary decreases in amplitude by up to 70% were tolerated without clinical consequences. However, repeated clinical examination is obligatory to recognise and treat early post-operative palsy


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 170 - 170
1 Sep 2012
Alami GB Rumian A Chuinard C Roussanne Y Boileau P
Full Access

Purpose. While reverse shoulder arthroplasty (RSA) corrects vertical muscle imbalance, it cannot restore the horizontal imbalance seen in cuff-deficient shoulders with combined loss of active elevation and external rotation (CLEER). We report the medium-term results of the modified latissimus dorsi/teres major tendon transfer (L'Episcopo procedure) associated with RSA, performed via a single deltopectoral approach. Method. Sixteen CLEER patients underwent the procedure and were followed up at a mean of 49 months (range, 36–70). All patients had lost spatial control of their arm, were unable to maintain neutral rotation, and had abnormal infraspinatus and teres minor muscles on imaging. Outcome measures included Constant score (CS), Subjective Shoulder Value (SSV), and ADLER score (activities of daily living requiring external rotation). Results. Fifteen patients were satisfied or very satisfied. There were significant improvements (p<0.05) in active elevation (72 degrees to 139 degrees), active external rotation (−24 degrees to 4 degrees), CS (27 to 64), ADLER score (5.0 to 23.8) and SSV (23% to 77%). Active internal rotation decreased from 6 to 3 points. Scapular notching was observed in 3 patients and spurs in 3 patients. One deep infection required two-stage revision of the prosthesis and the patient was disappointed with the result. One patient required reoperation (arthrolysis and acromioclavicular joint excision). Conclusion. Reverse shoulder arthroplasty combined with the modified L'Episcopo procedure improves shoulder function in patients with CLEER. Patients regain spatial control of their arm. The observed internal rotation loss has led us to modify the surgical technique by fixing the transferred tendons more posteriorly on the humerus


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 137 - 140
1 Jan 2002
Piska M Yang L Reed M Saleh M

An innovative Kirschner (K-) wire point was developed and compared in fresh pig femora in terms of drilling efficiency and temperature elevation with the trochar and diamond points currently used in clinical practice. The tips of thermal couples were machined to the defined geometry and the temperature measured during drilling. Using the same drill speed (rev/min) and feed rate, the new K-wire point produced the lowest thrust force and torque as measured by a Kistler dynamometer. Drill point temperatures were highest with the trochar geometry (129 ± 6°C), followed by the diamond (98 ± 7°C). The lowest temperatures were recorded with the Medin K-wire (66 ± 2°C). On repeated drilling it could be used for up to 30 holes before reaching the less satisfactory drill performance of the diamond tip. The new K-wire provides a better alternative as it requires less effort for insertion, generates less heat and may be re-used