General Orthopaedics

JOINT LINE ELEVATION IS ASSOCIATED WITH INCREASED POLYETHYLENE WEAR IN CRUCIATE-RETAINING TKR

The International Society for Technology in Arthroplasty (ISTA), 29th Annual Congress, October 2016. PART 3.



Abstract

Introduction

Wear debris from polyethylene tibial inserts has been associated with limited longevity of total knee replacements (TKRs). While material factors were studied extensively and considerable progress has been made, there is little knowledge about surgical factors, particularly on how the wear rate is related to implant positioning.

It was the purpose of this study to determine the combined effect of patient and implant positioning factors on the volumetric wear rate of TKRs. Our hypothesis was that implant alignment has a significant impact on the wear rate when controlled for other patient factors.

Methods

This study included 59 tibial inserts of a cruciate retaining TKR design (Nexgen, Zimmer Inc.). The patients' age, sex, weight, height, and implant size were obtained. All implants were scanned with a coordinate measuring machine. Volumetric wear was determined using an autonomous mathematical reconstruction method (Figure 1). Radiographs were used to determine the anatomic lateral distal femoral angle (aLDFA), anatomic medial proximal tibial angle (aMPTA), femoral tilt angle (FTA) and posterior tibial slope (PTS). Also, the patella position was assessed using the Blackburne-Peel Index (BPI) and the Insall-Salvati Ratio (Figure 2). General linear modeling (SPSS) was conducted in order to determine the most significant patient and implant positioning factors on wear rate.

Results

After adjustment for creep, the mean volumetric wear rate was 11.6 mm3/yr (Figure 2). According to the linear regression model wear increased with younger age (p=0.0014) and male sex (p<0.001). The wear rate was independent of patient weight (p=0.17). From the multiple positioning factors only BPI and tibial slope were significant and inversely correlated with wear (p=0.009 and 0.026, respectively). The average ISR was normal before and after surgery, whereas the BPI was only in the normal range prior to surgery, and dropped postop into pseudo-baja (p<0.001, Figure 3).

Discussion

The effect of male sex on wear volume can partially be explained by a larger average implant size; however, other unknown confounding factors may play a role too. The effect of younger age is likely related to higher patient activity. Based on previous gait analysis, we speculate that increasing tibial slope results in larger AP translations of the knee joint and thus more wear. Interestingly, BPI remained a highly significant factor when controlled for all other factors. The average BPI clearly dropped post-operatively, whereas the average ISR did not, indicating that not true patella baja, but a joint line elevation occurred due to the reconstruction. Joint line elevation may affect the quadriceps mechanism leading to higher contact forces and subsequent higher wear. Post-operative joint line elevation can be explained by the intention to keep bone loss at a minimum, while using thick polyethylene inserts. Further studies are needed to determine the trade-offs between bone conservation and reduction of wear rate. However, this study has revealed the importance of surgical factors regarding polyethylene wear reduction in TKR.

Acknowledgements

This study was funded by NIH grant R01AR059843.