Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 107 - 107
2 Jan 2024
Pastor T Zderic I Berk T Souleiman F Vögelin E Beeres F Gueorguiev B Pastor T
Full Access

Recently, a new generation of superior clavicle plates was developed featuring the variable-angle locking technology for enhanced screw positioning and optimized plate-to-bone fit design. On the other hand, mini-fragment plates used in dual plating mode have demonstrated promising clinical results. However, these two bone-implant constructs have not been investigated biomechanically in a human cadaveric model. Therefore, the aim of the current study was to compare the biomechanical competence of single superior plating using the new generation plate versus dual plating with low-profile mini-fragment plates.

Sixteen paired human cadaveric clavicles were assigned pairwise to two groups for instrumentation with either a 2.7 mm Variable Angle Locking Compression Plate placed superiorly (Group 1), or with one 2.5 mm anterior plate combined with one 2.0 mm superior matrix mandible plate (Group 2). An unstable clavicle shaft fracture AO/OTA15.2C was simulated by means of a 5 mm osteotomy gap. All specimens were cyclically tested to failure under craniocaudal cantilever bending, superimposed with bidirectional torsion around the shaft axis and monitored via motion tracking.

Initial stiffness was significantly higher in Group 2 (9.28±4.40 N/mm) compared to Group 1 (3.68±1.08 N/mm), p=0.003. The amplitudes of interfragmentary motions in terms of craniocaudal and shear displacement, fracture gap opening and torsion were significantly bigger over the course of 12500 cycles in Group 1 compared to Group 2; p≤0.038. Cycles to 2 mm shear displacement were significantly lower in Group 1 (22792±4346) compared to Group 2 (27437±1877), p=0.047.

From a biomechanical perspective, low-profile 2.5/2.0 dual plates demonstrated significantly higher initial stiffness, less interfragmentary movements, and higher resistance to failure compared to 2.7 single superior variable-angle locking plates and can therefore be considered as a useful alternative for diaphyseal clavicle fracture fixation especially in unstable fracture configurations.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 48 - 48
17 Apr 2023
Akhtar R
Full Access

To determine risk factors of infection in total knee arthroplasty

This descriptive study was conducted in the Department of Orthopedics for a duration of three years from January 2016 to January 2019. All patients undergoing primary total knee replacement were included in the study. Exclusion criteria were all patients operated in another hospital and revision total knee replacement. All patients were followed up at 2, 4, 8, 12 and 24 weeks post-operatively. Signs of inflammation and inflammatory markers such as total leukocyte count (TLC), C-reactive protein (CRP) and ESR were measured. Risk factors like age, body mass index (BMI), ASA, co-morbid conditions were also noted.

A total of 78 patients underwent primary unilateral Total Knee Replacement (TKR) during the study period. Of these, 30 (34.09%) were male and 48 (61.54%) female patients. Mean age of patients was 68.32 ± 8.54 years. Average BMI 25.89 Kg/m2 .Osteoarthritis was the pre-dominant cause of total knee replacement (94.87%). Among co-morbid factors 33.33% were diabetic, 28.20% having ischemic heart disease and 12.82% with chronic lung disease. Upon anaesthesia fitness pre-operatively, 91.02% patients had an American society of anaesthesiologist score (ASA) between 0–2 while 07 (8.97%) between 3- 5. Average duration of surgery was 85.62± 4.11 minutes. 6.41% cases got infected. In majority of the infected cases (60%), Staphylococcus aureus was the infective organism. Diabetes Mellitus (p=0.01) and Obesity (p=0.02) had a significant relation to post-operative infection.

Pre-operative risk evaluation and prevention strategies along with early recognition of infection and control can greatly reduce the risk of joint infection post-TKR which will not only improve the mobility of patient but also its morbidity and mortality as well.

Key Words:

C-reactive protein (CRP), Erythrocyte Sedimentation Rate (ESR), Staphylococcus aureus, Total Knee Arthroplasty (TKA)


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 10 - 10
2 Jan 2024
Martínez T Mariscal G Hevia E Barrios C
Full Access

The multimodal management of canal stenosis is increasing, and inhibitors of central sensitization are playing a crucial role in central sensitization processes. Pregabalin and gabapentin are antiepileptic drugs that reduce presynaptic excitability. The objective of this study was to investigate whether the use of pregabalin and gabapentin is effective in the symptomatic management of canal stenosis.

A literature search was conducted in four databases. The inclusion criteria were studies that compared pregabalin or gabapentin with a control group in lumbar canal stenosis. Randomized clinical trials and a comparative retrospective cohort study were included. The main clinical endpoints were VAS/NRS, ODI, and RDQ (Roland Morris Disability Questionnaire) at 2, 4, 8 weeks, and 3 months, adverse events, and walking distance were also collected. Data were combined using Review Manager 5.4 software.

Six studies and 392 patients were included. The mean age was 60.25. No significant differences were observed in VAS at 2, 4, and 8 weeks: (MD: 0.23; 95% CI: −0.63-1.09), (MD: −0.04; 95% CI: −0.64 to −0.57), and (MD: −0.6; 95% CI: −1.22 to 0.02). Significant differences were observed in favor of pregabalin with respect to VAS at three months: (MD: −2.97; 95% CI: −3.43 to −2.51). No significant differences were observed in ODI (MD: −3.47; 95% CI: −7.15 to −0.21). Adverse events were significantly higher in the pregabalin/gabapentin group (OR 5.88, 95%CI 1.28-27.05). Walking distance and RDQ could not be compared, although the results were controversial.

Gabapentinoids have not been shown to be superior to other drugs used in the treatment of LSS or to placebo. However, they have shown a higher incidence of adverse effects, improved results in VAS at 3 months, and a slight improvement in ambulation at 4 months in combination with NSAIDs compared to NSAIDs in monotherapy.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 104 - 104
11 Apr 2023
Vadgaonkar A Faymonville C Obertacke U
Full Access

Osteoarthritis (OA) is the most common disorder of the Sternoclavicular Joint (SCJ). In our case-control study, we evaluated the relationship between clavicular length and OA at the SCJ.

CT scans of adults presenting to the Emergency Department of our hospital were examined to look for OA, defined as the presence of osteophytes, subchondral cysts, or cortical sclerosis at the SCJ. Medial-most and lateral-most points of the clavicle were marked on the slices passing through the SC and AC joints respectively. Using x, y, and z-axis coordinates from the DICOM metadata, clavicular length was calculated as the distance between these two points with 3D geometry.

Preliminary data of 334 SCJs from 167 patients (64% males, 36% females) with a mean age of 48.5 ± 20.5 years were analysed. Multivariate regression models revealed that age and clavicular length were independent risk factors for OA while gender did not reach statistical significance. A 1mm increase in length was associated with 9% and 7% reduction in the odds of developing OA on the left and the right respectively. Comparing the mean clavicular length using t-test showed a significantly shorter clavicle in the group with OA (145.8 vs 152.7, p=0.0001, left and 144.2 vs 150.3, p=0.0007, right).

Our data suggest that the risk of developing OA at the SCJ is higher for shorter clavicles. This could be of clinical relevance in cases of clavicular fracture where clavicular shortening might lead to a higher risk of developing OA. Biomechanical studies are needed to find out the mechanism of this effect.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 113 - 113
2 Jan 2024
García-Rey E Gómez-Barrena E
Full Access

Pelvic bone defect in patients with severe congenital dysplasia of the hip (CDH) lead to abnormalities in lumbar spine and lower limb alignment that can determine total hip arthroplasty (THA) patients' outcome. These variables may be different in uni- or bilateral CDH.

We compared the clinical outcome and the spinopelvic and lower limb radiological changes over time in patients undergoing THA due to uni- or bilateral CHD at a minimum follow-up of five years.

Sixty-four patients (77 hips) undergoing THA due to severe CDH between 2006 and 2015 were analyzed: Group 1 consisted of 51 patients with unilateral CDH, and group 2, 113 patients (26 hips) with bilateral CDH. There were 32 females in group 1 and 18 in group 2 (p=0.6). The mean age was 41.6 years in group 1 and 53.6 in group 2 (p<0.001). We compared the hip, spine and knee clinical outcomes. The radiological analysis included the postoperative hip reconstruction, and the evolution of the coronal and sagittal spinopelvic parameters assessing the pelvic obliquity (PO) and the sacro-femoro-pubic (SFP) angles, and the knee mechanical axis evaluating the tibio-femoral angle (TFA).

At latest follow-up, the mean Harris Hip Score was 88.6 in group 1 and 90.7 in group 2 (p=0.025). Postoperative leg length discrepancy of more than 5 mm was more frequent in group 1 (p=0.028). Postoperative lumbar back pain was reported in 23.4% of the cases and knee pain in 20.8%, however, there were no differences between groups. One supracondylar femoral osteotomy and one total knee arthroplasty were required. The radiological reconstruction of the hip was similar in both groups. The PO angle improved more in group 1 (p=0.01) from the preoperative to 6-weeks postoperative and was constant at 5 years. The SFP angle improved in both groups but there were no differences between groups (p=0.5). 30 patients in group 1 showed a TFA less than 10º and 17 in group 2 (p=0.7).

Although the clinical outcome was better in terms of hip function in patients with bilateral CDH than those with unilateral CDH, the improvement in low back and knee pain was similar. Patients with unilateral dysplasia showed a better correction of the PO after THA. All spinopelvic and knee alignment parameters were corrected and maintained over time in most cases five years after THA.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 117 - 117
2 Jan 2024
Hankenson K
Full Access

Growth factors produced by inflammatory cells and mesenchymal progenitors are required for proper bone regeneration. Signaling pathways activated downstream of these proteins work in concert and synergistically to drive osteoblast and/or chondrocyte differentiation. While dysregulation can result in abnormal healing, activating these pathways in the correct spatiotemporal context can enhance healing. Bone morphogenetic protein (BMP) signaling is well-recognized as being required for bone regeneration, and BMP is used clinically to enhance bone healing. However, it is imperative to develop new therapeutics that can be used alone or in conjunction with BMP to drive even more robust healing. Notch signaling is another highly conserved signaling pathway involved in tissue development and regeneration. Our work has explored Notch signaling during osteoblastogenesis and bone healing using both in vitro studies with human primary mesenchymal progenitor cells and in vivo studies with genetically modified mouse models. Notch signaling is required and sufficient for osteoblast differentiation, and is required for proper bone regeneration. Indeed, intact Notch signaling through the Jagged-1 ligand is required for BMP induced bone formation. On-going work continues to explore the intersection between BMP and Notch signaling, and determining cell types that express Notch receptors and Notch ligands during bone healing. Our long-term objective is to develop Notch signaling as a clinical therapy to repair bone.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 57 - 57
17 Apr 2023
Bae T Baek H Kwak D
Full Access

It is still difficult to determine an appropriate hinge position to prevent fracture in the lateral cortex of tibia in the process of making an open wedge during biplane open wedge high tibial osteotomy. The objective of this study was to present a biomechanical basis for determining the hinge position as varus deformity.

T Three-dimensional lower extremity models were constructed using Mimics. The tibial wedge started at 40 mm distal to the medial tibial plateau, and osteotomy for three hinge positions was performed toward the head of the fibula, 5 mm proximal from the head of the fibula, and 5 mm distal from the head of the fibula. The three tibial models were made with varus deformity of 5, 10, 15 degrees with heterogeneous material properties. These properties were set to heterogeneous material properties which converted from Hounsfield's unit to Young's modulus by applying empirical equation in existing studies. For a loading condition, displacement at the posterior cut plane was applied referring to Hernigou's table considering varus deformity angle. All computational analyses were performed to calculate von-mises stresses on the tibial wedges.

The maximum stress increased to an average of 213±9% when the varus angle was 10 degrees compared to 5 degrees and increased to an average of 154±8.9% when the varus angle was 15 degrees compared to 10 degrees. In addition, the maximum stress of the distal position was 19 times higher than that of the mid position and 5 times higher than that of the proximal position on average.

Conclusion:

For varus deformity angles, the maximum stress of the tibial wedge tended to increase as the varus deformity angle increased. For hinge position of tibial wedge, maximum stress was the lowest in the mid position, while the highest in the distal position.

*This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (NRF-2022R1A2C1009995)


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 62 - 62
17 Apr 2023
Herren A Luczak A Amin A Hall A
Full Access

Early changes within articular cartilage during human idiopathic osteoarthritis are poorly understood. However alterations to chondrocyte morphology occur with the development of fine cytoplasmic processes and cell clusters, potentially playing a role in cartilage degeneration. The aggrecanase ADAMTS-4 (A disintegrin and metalloproteinase with thrombospondin motifs-4) has been implicated as an important factor in cartilage degradation, so we investigated the relationship between chondrocyte morphology and levels of ADAMTS-4 in both non-degenerate and mildly osteoarthritic human cartilage.

Human femoral heads were obtained following consent from patients undergoing hip arthroplasty following femoral neck fracture. Cartilage explants of normal (grade 0; G0) and mildly osteoarthritic (grade 1; G1) cartilage were labelled with the cytoplasmic dye CMFDA (5-chloromethylfluorescein-diacetate). Explants were cryosectioned (30μm sections), and labelled for ADAMTS-4 by fluorescence immunohistochemistry. Sections were imaged with confocal microscopy, allowing the semi-quantitative analysis of ADAMTS-4 and 3D visualisation of in situ cell morphology.

With cartilage degeneration from G0 to G1, there was a decrease in the proportion of chondrocytes with normal rounded morphology (P<0.001) but an increase in the proportion of cells with processes (P<0.01) and those in clusters (P<0.001;[4(1653)]; femoral heads:cells). Although average levels of ADAMTS-4 for all cells was the same between G0 and G1 (P>0.05), a change was evident in the distribution curves for cell-specific ADAMTS-4 labelling. Cell-by-cell analysis showed that ADAMTS-4 levels were higher in chondrocytes with cytoplasmic processes compared to normal cells (P=0.044) however cells in clusters had lower levels than normal cells (P=0.003;[3(436)]). Preliminary data suggested that ADAMTS-4 levels increased with larger chondrocyte clusters.

These results suggest complex heterogeneous changes to levels of cell-associated ADAMTS-4 with early cartilage degeneration – increasing in cells with processes and initially decreasing in clusters. Increased levels of ADAMTS-4 are likely to produce focal areas of matrix weakness potentially leading to early cartilage degeneration.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 66 - 66
2 Jan 2024
Nikody M Li J Koper D Balmayor E Habibovic P Moroni L
Full Access

Critical-sized bone defects remain challenging in the clinical setting. Autologous bone grafting remains preferred by clinicians. However, the use of autologous tissue is associated with donor-site morbidity and limited accessibility to the graft tissue. Advances in the development of synthetic bone substitutes focus on improving their osteoinductive properties. Whereas osteoinductivity has been demonstrated with ceramics, it is still a challenge in case of polymeric composites. One of the approaches to improve the regenerative properties of biomaterials, without changing their synthetic character, is the addition of inorganic ions with known osteogenic and angiogenic properties. We have previously reported that the use of a bioactive composite with high ceramic content composed of poly(ethyleneoxide terephthalate)/poly(butylene terephthalate) (1000PEOT70PBT30, PolyActive, PA) and 50% beta-tricalcium phosphate (β-TCP) with the addition of zinc in a form of a coating of the TCP particles can enhance the osteogenic differentiation of human mesenchymal stromal cells (hMSCs) (3). To further support the regenerative properties of these scaffolds, inorganic ions with known angiogenic properties, copper or cobalt, were added to the coating solution.

β-TCP particles were immersed in a zinc and copper or zinc and cobalt solution with a concentration of 15 or 45 mM. 3D porous scaffolds composed of 1000PEOT70PBT30 and pure or coated β-TCP were additively manufactured by 3D fibre deposition. The osteogenic and angiogenic properties of the fabricated scaffolds were tested in vitro through culture with hMSCs and human umbilical vein endothelial cells, respectively. The materials were further evaluated through ectopic implantation in an in vivo mini-pig model. The early expression of relevant osteogenic gene markers (collagen-1, osteocalcin) of hMSCs was upregulated in the presence of lower concentration of inorganic ions. Further analysis will focus on the evaluation of ectopic bone formation and vascularisation of these scaffolds after implantation in a mini-pig ectopic intramuscular model.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 127 - 127
2 Jan 2024
Moschini G
Full Access

Tendinopathy is the most common form of chronic tendon disorders, accounting for up 30% of all musculoskeletal clinic visits [1]. In tendon disease, the largely avascular tendon tissue often becomes hypervascularized and fibrotic [2]. As blood vessel growth and angiogenic signaling molecules are often induced by the lack of adequate nutrients and oxygen, hypoxic signaling is speculated to be a root cause of tendon neovascularization and tendinopathy [3,4,5]. However, how the vascular switch is initiated in tendons, and how vascularization contributes to tendon pathology remains unknown. In this talk, we provide evidence that HIF-1α is implicated in tendon disease and HIF-1α stabilization in human tendon cells induces vascular recruitment of endothelial cells via VEGFa secretion. More interesting, HIF-1α stabilization in tendon cells in vivo, seems to recapitulate all main features of fibrotic human tendon disease, including vascular ingrowth, matrix disorganization, changes in tissue mechanics, cell proliferation and innervation. Surprisingly, in vivo knock-out of VEGFa rescued angiogenesis in the tendon core but it did not affect tendon mechanical properties and tissue pathophysiological changes, suggesting that blood vessels ingrowth might not be a primary cause but a consequence of HIF-1α activation.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 65 - 65
17 Apr 2023
Tacchella C Lombardero SM Clutton E Chen Y Crichton M
Full Access

In this work, we propose a new quantitative way of evaluating acute compartment syndrome (ACS) by dynamic mechanical assessment of soft tissue changes. First, we have developed an animal model of ACS to replicate the physiological changes during the condition. Secondly, we have developed a mechanical assessment tool for quantitative pre-clinical assessment of ACS. Our hand-held indentation device provides an accurate method for investigations into the local dynamic mechanical properties of soft tissue and for in-situ non-invasive assessment and monitoring of ACS.

Our compartment syndrome model was developed on the cranial tibial and the peroneus tertius muscles of a pig's leg (postmortem). The compartment syndrome pressure values were obtained by injecting blood from the bone through the muscle.

To enable ACS assessment by a hand-held indentation device we combined three main components: a load cell, a linear actuator and a 3-axis accelerometer. Dynamic tests were performed at a frequency of 0.5 Hz and by applying an amplitude of 0.5 mm.

Another method used to observe the differences in the mechanical properties inside the leg was a 3D Digital Image Correlation (3D-DIC). Videos were taken from two different positions of the pig's leg at different pressure values: 0 mmHg, 15 mmHg and 40 mmHg. Two strains along the x axis (Exx) and y axis (Eyy) were measured.

Between the two pressure cases (15 mmHg and 40 mmHg) a clear deformation of the model is visible. In fact, the bigger the pressure, the more visible the increase in strain is.

In our animal model, local muscle pressures reached values higher than 40 mmHg, which correlate with observed human physiology in ACS. In our presentation we will share our dynamic indentation results on this model to demonstrate the sensitivity of our measurement techniques.

Compartment syndrome is recognised as needing improved clinical management tools. Our approach provides both a model that reflects physiological behaviour of ACS, and a method for in-situ non-invasive assessment and monitoring.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 129 - 129
2 Jan 2024
Gehwolf R
Full Access

Tendons are characterised by an inferior healing capacity when compared to other tissues, ultimately resulting in the formation of a pathologically altered extracellular matrix structure. Although our understanding of the underlying causes for the development and progression of tendinopathies remains incomplete, mounting evidence indicates a coordinated interplay between tendon-resident cells and the ECM is critical. Our recent results demonstrate that the matricellular protein SPARC (Secreted protein acidic and rich in cysteine) is essential for regulating tendon tissue homeostasis and maturation by modulating the tissue mechanical properties and aiding in collagen fibrillogenesis [1,2]. Consequently, we speculate that SPARC may also be relevant for tendon healing.

In a rat patellar tendon window defect model, we investigated whether the administration of recombinant SPARC protein can modulate tendon healing. Besides the increased mRNA expression of collagen type 1 and the downregulation of collagen type 3, a robust increase in the expression of pro-regenerative fibroblast markers in the repair tissue after a single treatment with rSPARC protein was observed. Additionally, pro-fibrotic markers were significantly decreased by the administration of rSPARC. Determination of structural characteristics was also assessed, indicating that the ECM structure can be improved by the application of rSPARC protein. Therefore, we believe that SPARC plays an important role for tendon healing and the application of recombinant SPARC to tendon defects has great potential to improve functional tendon repair.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 19 - 19
2 Jan 2024
Castagno S Birch M van der Schaar M McCaskie A
Full Access

Precision health aims to develop personalised and proactive strategies for predicting, preventing, and treating complex diseases such as osteoarthritis (OA). Due to OA heterogeneity, which makes developing effective treatments challenging, identifying patients at risk for accelerated disease progression is essential for efficient clinical trial design and new treatment target discovery and development.

To create a reliable and interpretable precision health tool that predicts rapid knee OA progression over a 2-year period from baseline patient characteristics using an advanced automated machine learning (autoML) framework, “Autoprognosis 2.0”.

All available 2-year follow-up periods of 600 patients from the FNIH OA Biomarker Consortium were analysed using “Autoprognosis 2.0” in two separate approaches, with distinct definitions of clinical outcomes: multi-class predictions (categorising disease progression into pain and/or radiographic progression) and binary predictions. Models were developed using a training set of 1352 instances and all available variables (including clinical, X-ray, MRI, and biochemical features), and validated through both stratified 10-fold cross-validation and hold-out validation on a testing set of 339 instances. Model performance was assessed using multiple evaluation metrics. Interpretability analyses were carried out to identify important predictors of progression.

Our final models yielded higher accuracy scores for multi-class predictions (AUC-ROC: 0.858, 95% CI: 0.856-0.860) compared to binary predictions (AUC-ROC: 0.717, 95% CI: 0.712-0.722). Important predictors of rapid disease progression included WOMAC scores and MRI features. Additionally, accurate ML models were developed for predicting OA progression in a subgroup of patients aged 65 or younger.

This study presents a reliable and interpretable precision health tool for predicting rapid knee OA progression. Our models provide accurate predictions and, importantly, allow specific predictors of rapid disease progression to be identified. Furthermore, the transparency and explainability of our methods may facilitate their acceptance by clinicians and patients, enabling effective translation to clinical practice.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 121 - 121
2 Jan 2024
Liepe K Baehr M
Full Access

After knee replacement, therapy resistant, chronic synovitis is common and leads to effusion and pain.

A cohort of 55 patients with 57 knee replacements and chronic synovitis underwent radiosynoviorthesis. In summary, 101 joints were treated using 182±9 MBq of 90Y-citrate. The number of radiosynoviorthesis ranged from 1 to 4 (53%, 21%, 23%, and 4%). Every patient received a 99mTc-MDP scintigraphy before and three months after every radiosynoviorthesis. Follow-up ranged from 5.7 to 86.7 months. For qualitative analysis, an four steps scoring was used (0 = no response or worsening, 1 = slight, 2 = good, 3 = excellent response). For quantification, the uptake was determined within the 99mTc-MDP scintigraphy soft tissue phase before and after therapy.

At the end of long-term follow-up 27% of patients have an excellent, 24% good, 30% slight and 20% no response. The duration of response was 7.5±8.3 months (maximum 27 months). In repeated treatment, the effect after the first therapy was lesser than in patients who received a single treatment in total. However, three months after the last radiosynoviorthesis, patients with repeated treatment showed a similar effectiveness than single treated patients. At the end of long-term follow-up, patients with repeated radiosynoviorthesis had a higher effectiveness at similar duration response. In the 99mTc-MDP scan 65% of patients showed a reduction of uptake. When comparing subjective and objective response 78% of patients showed a concordance in both, symptoms and scintigraphy. Pilot histological analysis revealed that the synovitis is triggered by small plastic particles.

Radiosynoviorthesis is effective in patients with knee replacement and chronic synovitis. It shows good subjective and objective response rates and long response duration. Repeated treatment leads to a stronger long-time response. The chronic synovitis is caused by plastic particles, which result from the abrasion of the polymeric inlay of endoprothesis.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 60 - 60
17 Apr 2023
Schiltenwolf M Neubauer E Videva M
Full Access

Chronic pain is recognised as a problem worldwide. Interdisciplinary multimodal pain therapy (MMPT) is currently the gold standard of treatment.

The aim of the present prospective observational study is to research whether chronic pain patients form an intention for lifestyle change during a 4-week-long treatment at the Outpatient Clinic for Pain Therapy and Conservative Orthopedics in Heidelberg, Germany, and how sustainable this change is after 3 months. In addition, we theorized a connection between standardised survey endpoints and the number of therapy units perceived as helpful (TPAH). Finally, the effect of socio-demographic factors on patient perceptions were put into perspective.

Clinical data was collected via 3-part-questionnaires from 95 German-speaking patients at 4 checkpoints between 05/2020 and 11/2021 at admission (T1), after 2 weeks (T2), at discharge (T3) and 3 months post-treatment (T4). The questionnaires consisted of already established scores for surveying chronic pain patients, such as the von Korff Chronification Scale, ODI, HADS, PSEQ/FESS, and FABQ, a grading scale for each therapy unit, and free answers.

Patients were most likely to implement Group Walking in their everyday lives. A higher number of TPAH neither lowered nor improved significantly the change in lifestyle, but both a higher number and bigger lifestyle changes improved significantly the scores across the standardised surveys. Furthermore, no significant change in intention happened between the second and the fourth week. Physical components were perceived throughout as more helpful.

The results of this research support the efficacy of MMPT in multi-faceted improving of the patient's well-being and lowering the possibility for pain chronification. A higher number of TPAH could be translated as having more available techniques to combat chronic pain in everyday life. The number of TPAH and the amount of lifestyle change both influence positively the survey scores, yet no connection between them was found. A third factor could be the reason for this constellation. The possibility that the more mental therapies are offered, the more likely it is for those to be perceived as helpful, cannot be excluded either. Further research is required on both topics.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 20 - 20
2 Jan 2024
Novais E Brown E Ottone O Tran V Lepore A Risbud M
Full Access

Despite the clinical relevance of back pain and intervertebral disc herniation, the lack of reliable models has strained their molecular understanding. We characterized the lumbar spinal phenotype of C57BL/6 and SM/J mice during aging. Interestingly, old SM/J lumbar discs evidenced accelerated degeneration, associated with high rates of disc herniation. SM/J AF's and degenerative human's AF transcriptomic profiles showed altered immune cell, inflammation, and p53 pathways. Old SM/J mice presented increased neuronal markers in herniated discs, thicker subchondral bone, and higher sensitization to pain. Dorsal root ganglia transcriptomic studies and spinal cord analysis exhibited increased pain and neuroinflammatory markers associated with altered extracellular matrix regulation. Immune system single-cell and tissue level analysis showed distinctive T-cell and B-cell modulation and negative correlation between mechanical allodynia and INF-α, IL-1β, IL2, and IL4, respectively. This study underscores the multisystemic network behind back pain and highlights the role of genetic background and the immune system in disc herniation disease.

Acknowledgments: This study is supported by grants from the National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS) R01AR055655, R01AR064733, R01AR074813 to MVR.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 65 - 65
2 Jan 2024
Callens S Burdis R Cihova M Kim J Lau Q Stevens MM
Full Access

Cells typically respond to a variety of geometrical cues in their environment, ranging from nanoscale surface topography to mesoscale surface curvature. The ability to control cellular organisation and fate by engineering the shape of the extracellular milieu offers exciting opportunities within tissue engineering. Despite great progress, however, many questions regarding geometry-driven tissue growth remain unanswered.

Here, we combine mathematical surface design, high-resolution microfabrication, in vitro cell culture, and image-based characterization to study spatiotemporal cell patterning and bone tissue formation in geometrically complex environments. Using concepts from differential geometry, we rationally designed a library of complex mesostructured substrates (101-103 µm). These substrates were accurately fabricated using a combination of two-photon polymerisation and replica moulding, followed by surface functionalisation. Subsequently, different cell types (preosteoblasts, fibroblasts, mesenchymal stromal cells) were cultured on the substrates for varying times and under varying osteogenic conditions. Using imaging-based methods, such as fluorescent confocal microscopy and second harmonic generation imaging, as well as quantitative image processing, we were able to study early-stage spatiotemporal cell patterning and late-stage extracellular matrix organisation. Our results demonstrate clear geometry-dependent cell patterning, with cells generally avoiding convex regions in favour of concave domains. Moreover, the formation of multicellular bridges and collective curvature-dependent cell orientation could be observed. At longer time points, we found clear and robust geometry-driven orientation of the collagenous extracellular matrix, which became apparent with second harmonic generation imaging after ∼2 weeks of culture.

Our results highlight a key role for geometry as a cue to guide spatiotemporal cell and tissue organisation, which is relevant for scaffold design in tissue engineering applications. Our ongoing work aims at understanding the underlying principles of geometry-driven tissue growth, with a focus on the interactions between substrate geometry and mechanical forces.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 115 - 115
11 Apr 2023
Tay M Carter M Bolam S Zeng N Young S
Full Access

Unicompartmental knee arthroplasty (UKA) has a higher risk of revision than total knee arthroplasty, particularly for low volume surgeons. The recent introduction of robotic-arm assisted systems has allowed for increased accuracy, however new systems typically have learning curves. The objective of this study was to determine the learning curve of a robotic-arm assisted system for UKA.

Methods A total of 152 consecutive robotic-arm assisted primary medial UKA were performed by five surgeons between 2017 and 2021. Operative times, implant positioning, reoperations and patient-reported outcome measures (PROMS; Oxford Knee Score, EuroQol-5D, and Forgotten Joint Score) were recorded.

There was a learning curve of 11 cases with the system that was associated with increased operative time (13 minutes, p<0.01) and improved insert sizing over time (p=0.03). There was no difference in implant survival (98.2%) between learning and proficiency phases (p = 0.15), and no difference in survivorship between ‘high’ and ‘low’ usage surgeons (p = 0.23) at 36 months. There were no differences in PROMS related to the learning curve. This suggested that the learning curve did not lead to early adverse effects in this patient cohort.

The introduction of a robotic-arm assisted UKA system led to learning curves for operative time and implant sizing, but there was no effect on patient outcomes at early follow- up. The short learning curve was independent of UKA usage and indicated that robotic-arm assisted UKA may be particularly useful for low-usage surgeons.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 23 - 23
2 Jan 2024
Dragonas C Waseem S Simpson A Leivadiotou D
Full Access

The advent of modular implants aims to minimise morbidity associated with revision of hemiarthroplasty or total shoulder arthroplasty (TSA) to reverse shoulder arthroplasty (RSR) by allowing retention of the humeral stem. This systematic review aimed to summarise outcomes following its use and reasons why modular humeral stems may be revised.

A systematic review of Pubmed, Medline and EMBASE was performed according to PRISMA guidelines of all patients undergoing revision of a modular hemiarthroplasty or TSA to RSR. Primary implants, glenoid revisions, surgical technique and opinion based reports were excluded. Collected data included demographics, outcomes and incidence of complications.

277 patients were included, with a mean age of 69.8 years (44-91) and 119 being female. Revisions were performed an average of 30 months (6-147) after the index procedure, with the most common reason for revision being cuff failure in 57 patients. 165 patients underwent modular conversion and 112 underwent stem revision. Of those that underwent humeral stem revision, 18 had the stem too proximal, in 15 the stem was loose, 10 was due to infection and 1 stem had significant retroversion. After a mean follow up of 37.6 months (12-91), the Constant score improved from a mean of 21.8 to 48.7. Stem revision was associated with a higher complication rate (OR 3.13, 95% CI 1.82-5.39).

The increased use of modular stems has reduced stem revision, however 40% of these implants still require revision due to intra-operative findings. Further large volume comparative studies between revised and maintained humeral stems post revision of modular implants can adequately inform implant innovation to further improve the stem revision rate.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 101 - 101
2 Jan 2024
Firth A Lee K van Duren B Berber R Matar H Bloch B
Full Access

Stiffness is reported in up to 16% of patients after total knee replacement (TKR)1. Treatment of stiffness after TKR remains a challenge. Manipulation under anaesthesia (MUA) accounts for between 6%-36% of readmissions following TKR2,3. The outcomes of MUA remain variable/unpredictable. Post-operative CPM is used as an adjuvant to MUA, potentially offering improved ROM, however, remains the subject of debate. We report a retrospective study comparing MUA with and without post-operative CPM.

In our institution patients undergoing MUA to receive CPM post-operatively. Owing to the COVID-19 pandemic hospital admissions were limited. During this period MUA procedures were undertaken without CPM. Two cohorts were included: 1) MUA + post-operative CPM 2) Daycase MUA. Patients’ demographics, pre-manipulation ROM, post-MUA ROM, and ROM at final follow-up were recorded.

Between 2017-2022 126 patients underwent MUA and were admitted for CPM and 42 had daycase MUA. The median Age was 66.5 and 64% were female. 57% had extension deficit (>5o), 70% had flexion deficit (< 90o), and 37% had both. The mean Pre-operative ROM was 72.3o(SD:18.3o) vs. 68.5o(19.0o), ROM at MUA was 95.5o(SD:20.7o) vs 108.3o(SD:14.1o) [p< 0.01], and at final follow-up 87.4o(SD:21.9o) vs. 92.1o(SD:18.2o) for daycase and CPM groups respectively. At final follow-up for the daycase and CPM groups respectively 10% vs. 7% improved, 29% vs. 13% maintained, and 57% vs. 79% regressed from the ROM achieved at MUA. The mean percentage of ROM gained at MUA maintained at final follow-up was 92%(SD:17) and 85%(SD:14)[p=0.03] for daycase and CPM groups respectively.

There was no significant difference in ROM achieved at final follow-up despite the significantly greater improvement in ROM achieved at MUA for the CPM group. The CPM group lost a greater ROM after MUA (15% vs. 8%). We conclude that post-operative CPM does not improve ROM achieved after MUA.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 41 - 41
17 Apr 2023
Hayward S Miles A Keogh P Gheduzzi S
Full Access

Lower back pain (LBP) is a global problem. Countless in vitro studies have attempted to understand LBP and inform treatment protocols such as disc replacement devices (DRDs). A common method of reporting results is applying a linear fit to load-displacement behaviour, reporting the gradient as the specimen stiffness in that axis. This is favoured for speed, simplicity and repeatability but neglects key aspects including stiffening and hysteresis. Other fits such as polynomials and double sigmoids better address these characteristics, but solution parameters lack physical representation. The aim of this study was to implement an automated method to fit spinal load-displacement behaviour using viscoelastic models.

Six porcine lumbar spinal motion segments were dissected to produce isolated disc specimens. These were potted in Wood's metal, ensuring the disc midplane remained horizontal, sprayed with 0.9% saline and wrapped in saline-soaked tissue and plastic wrap to prevent dehydration. Specimens were tested using the University of Bath spine simulator operating under position control with a 400N axial preload.

Specimens were approximated using representative viscoelastic elements. These models were constructed in MATLAB Simulink R2020b using the SimScape library. Solution coefficients were determined by minimizing the sum of squared errors cost function using a non-linear least squares optimization method.

The models matched experimental data well with a mean % difference in model and specimen enclosed area below 6% across all axes. This indicates the ability of the model to accurately represent energy dissipated. The final models demonstrated reduced RMSEs factors of 3.6, 1.1 and 9.5 smaller than the linear fits for anterior-posterior shear, mediolateral shear and axial rotation respectively.

These nonlinear viscoelastic models exhibit significantly increased qualities of fit to spinal load-displacement behaviour when compared to linear approximations. Furthermore, they have the advantage of solution parameters which are directly linked to physical elements: springs and dampers. The results from this study could be instrumental in improving the design of DRDs as a mechanism for treating LBP.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 3 - 3
2 Jan 2024
Workineh Z Muñoz-Moya E Wills C Noailly J
Full Access

Intervertebral discs (IVD) provide flexibility to the back and ensure functional distributions of the spinal loads. They are avascular, and internal diffusion-dependent metabolic transport is vital to supply nutrients to disc cells1, but interactions with personalized IVD shapes and mechanics remain poorly explored. Poromechanical finite element models of seven personalized lumbar IVD geometries, with mean heights ranging from 8 to 16 mm were coupled with a reactive oxygen, glucose and lactate transport model linked with tissue deformations and osmosis . In previous studies, reduced formulations of the divergence of the solute flux (∇ .J = ∇ . (DC) = ∇ D. ∇ C +D∇ 2C) ignored the dependence of the diffusion on the deformation gradients, ∇ D.C. We simulated this phenomenon to explore its significance in mechano-metabolic -transport couplings, in the different geometries, over 24h of simulated rest (8h) and physical activity (16h). ∇ D.C affected the daily variations of glucose concentrations in IVD thinner than 12 mm but with neglectable variation ranges, while not considering ∇ D. ∇ C in taller discs only slightly overestimated the glucose concentration. Most importantly, tall IVD had nearly 60% less glucose than thin IVD, with local drops below the concentration of 0.5 mM, considered to be critical for disc cells3, in the anterior nucleus pulposus. On the one hand, previous reduced formulations for mechanometabolic-transport models of the IVD seem acceptable, even for patient-specific modelling. On the other hand, tall IVD might suffer from unfortunate combinations of deformation-dependent solute diffusion and large diffusion distances, which may favor early

Acknowledgements: Catalan Government and European Commission (2020 BP 00282; ERC-2021-CoG-O-Health-101044828)


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 2 - 2
2 Jan 2024
Mariscal G Burgos J Antón-Rodrigálvarez L Hevia E Barrios C
Full Access

In healthy subjects, respiratory maximal volumes are highly dependent on the sagittal range of motion of the T7-T10 segment. In AIS, the abolition of T7-T10 dynamics related to the stiffness induced by the apex region in Lenke IA curves could harm ventilation during maximal breathing. The aim of this study was to analyze the dynamics of the thoracic spine during deep breathing in AIS patients and in healthy matched controls. This is a cross-sectional, case-control study. 20 AIS patients (18 girls, Cobb angle, 54.7±7.9°; Risser 1.35±1.2) and 15 healthy volunteers (11 girls) matched in age (12.5 versus 15.8 yr. mean age) were included. In AIS curves, the apex was located at T8 (14) and T9 (6). Conventional sagittal radiographs of the whole spine were performed at maximal inspiration and exhalation. The ROM of each spinal thoracic functional segment (T1-T7, T7-T10, T10-T12) and the global T1-T12 ROM were measured. In healthy subjects, the mean T1-T12 ROM during forced breathing was 16.7±3.8. AIS patients showed a T1-T12 ROM of 1.1±1.5 (p<0.05), indicating a sagittal stiffness of the thoracic spine. A wide T7-T10 ROM (15.3±3.0) was found in healthy controls (91.6% of the T1–T12 ROM). AIS patients showed only 0.4±1.4 ROM at T7-T10 (36.4% of the T1-T12 ROM) (p<0.001). There was a significant positive correlation between the magnitude of T7-T10 kyphosis in maximal exhalation and both FVC (% of predicted FVC) and FEV1. In conclusion, Lenke 1A AIS patients show a restriction of the thoracic spine motion with an almost complete abolition of T7-T10 ROM, a crucial segment for deep breathing. T7-T10 stiffness could explain the ventilatory limitations found in AIS patients.


Bone & Joint 360
Vol. 11, Issue 4 | Pages 21 - 25
1 Aug 2022


Bone & Joint 360
Vol. 11, Issue 6 | Pages 15 - 18
1 Dec 2022

The December 2022 Hip & Pelvis Roundup360 looks at: Fix and replace: simultaneous fracture fixation and hip arthroplasty for acetabular fractures in older patients; Is the revision rate for femoral neck fracture lower for total hip arthroplasty than for hemiarthroplasty?; Femoral periprosthetic fractures: data from the COMPOSE cohort study; Dual-mobility cups and fracture of the femur; What’s the deal with outcomes for hip and knee arthroplasty outcomes internationally?; Osteochondral lesions of the femoral head: is costal cartilage the answer?


Bone & Joint 360
Vol. 11, Issue 4 | Pages 48 - 48
1 Aug 2022


Bone & Joint 360
Vol. 11, Issue 5 | Pages 48 - 48
1 Oct 2022


Bone & Joint 360
Vol. 12, Issue 1 | Pages 48 - 48
1 Feb 2023


Bone & Joint 360
Vol. 12, Issue 2 | Pages 6 - 9
1 Apr 2023
O’Callaghan J Afolayan J Ochieng D Rocos B


Bone & Joint 360
Vol. 12, Issue 3 | Pages 30 - 32
1 Jun 2023

The June 2023 Spine Roundup360 looks at: Characteristics and comparative study of thoracolumbar spine injury and dislocation fracture due to tertiary trauma; Sublingual sufentanil for postoperative pain management after lumbar spinal fusion surgery; Minimally invasive bipolar technique for adult neuromuscular scoliosis; Predictive factors for degenerative lumbar spinal stenosis; Lumbosacral transitional vertebrae and lumbar fusion surgery at level L4/5; Does recall of preoperative scores contaminate trial outcomes? A randomized controlled trial; Vancomycin in fibrin glue for prevention of SSI; Perioperative nutritional supplementation decreases wound healing complications following elective lumbar spine surgery: a randomized controlled trial.


Bone & Joint 360
Vol. 12, Issue 1 | Pages 3 - 4
1 Feb 2023
Ollivere B


Bone & Joint 360
Vol. 11, Issue 5 | Pages 46 - 47
1 Oct 2022
Das A


Bone & Joint 360
Vol. 12, Issue 4 | Pages 26 - 29
1 Aug 2023

The August 2023 Shoulder & Elbow Roundup360 looks at: Motor control or strengthening exercises for rotator cuff-related shoulder pain? A multi-arm randomized controlled trial; Does the choice of antibiotic prophylaxis influence reoperation rate in primary shoulder arthroplasty?; Common shoulder injuries in sport: grading the evidence; The use of medial support screw was associated with axillary nerve injury after plate fixation of proximal humeral fracture using a minimally invasive deltoid-splitting approach; MRI predicts outcomes of conservative treatment in patients with lateral epicondylitis; Association between surgeon volume and patient outcomes after elective shoulder arthroplasty; Arthroscopic decompression of calcific tendinitis without cuff repair; Functional outcome after nonoperative management of minimally displaced greater tuberosity fractures and predictors of poorer patient experience.


Bone & Joint 360
Vol. 12, Issue 4 | Pages 30 - 32
1 Aug 2023

The August 2023 Spine Roundup360 looks at: Changes in paraspinal muscles correspond to the severity of degeneration in patients with lumbar stenosis; Steroid injections are not effective in the prevention of surgery for degenerative cervical myelopathy; A higher screw density is associated with fewer mechanical complications after surgery for adult spinal deformity; Methylprednisolone following minimally invasive lumbar decompression: a large prospective single-institution study; Occupancy rate of pedicle screw below 80% is a risk factor for upper instrumented vertebral fracture following adult spinal deformity surgery; Deterioration after surgery for degenerative cervical myelopathy: an observational study from the Canadian Spine Outcomes and Research Network.


Bone & Joint 360
Vol. 11, Issue 6 | Pages 37 - 40
1 Dec 2022

The December 2022 Trauma Roundup360 looks at: Anterior approach for acetabular fractures using anatomical plates; Masquelet–Ilizarov for the management of bone loss post debridement of infected tibial nonunion; Total hip arthroplasty – better results after low-energy displaced femoral neck fracture in young patients; Unreamed intramedullary nailing versus external fixation for the treatment of open tibial shaft fractures in Uganda: a randomized clinical trial; The Open-Fracture Patient Evaluation Nationwide (OPEN) study: the management of open fracture care in the UK; Cost-utility analysis of cemented hemiarthroplasty versus hydroxyapatite-coated uncemented hemiarthroplasty; Unstable ankle fractures: fibular nail fixation compared to open reduction and internal fixation; Long-term outcomes of randomized clinical trials: wrist and calcaneus; ‘HeFT’y follow-up of the UK Heel Fracture Trial.


Bone & Joint 360
Vol. 11, Issue 5 | Pages 18 - 19
1 Oct 2022


Bone & Joint 360
Vol. 12, Issue 4 | Pages 48 - 48
1 Aug 2023


Bone & Joint 360
Vol. 12, Issue 2 | Pages 45 - 46
1 Apr 2023
Evans JT Whitehouse MR


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_4 | Pages 4 - 4
8 Feb 2024
Oliver WM Bell KR Carter TH White TO Clement ND Duckworth AD Molyneux SG
Full Access

This single-centre prospective randomised trial aimed to assess the superiority of operative fixation compared with non-operative management for adults with an isolated, closed humeral shaft fracture.

70 patients were randomly allocated to either open reduction and internal fixation (51%, n=36/70) or functional bracing (49%, n=34/70). 7 patients did not receive their assigned treatment (operative n=5/32, non-operative n=2/32); results were analysed based upon intention-to-treat. The primary outcome measure was the DASH score at 3 months. Secondary outcomes included treatment complications, union/nonunion, shoulder/elbow range of motion, pain and health-related quality of life (HRQoL).

At 3 months, 66 patients (94%) were available for follow-up; the mean DASH favoured surgery (operative 24.5, non-operative 39.4; p=0.006) and the difference (14.9 points) exceeded the MCID. Surgery was also associated with a superior DASH at 6wks (operative 38.4, non-operative 53.1; p=0.005) but not at 6 months or 1yr. Brace-related dermatitis affected 7 patients (operative 3%, non-operative 18%; OR 7.8, p=0.049) but there were no differences in other complications. 8 patients (11%) developed a nonunion (operative 6%, non-operative 18%; OR 3.8, p=0.140). Surgery was associated with superior early shoulder/elbow range of motion, and pain, EuroQol and SF-12 Mental Component Summary scores. There were no other differences in outcomes between groups.

Surgery confers early advantages over bracing, in terms of upper limb function, shoulder/elbow range of motion, pain and HRQoL. However, these benefits should be considered in the context of potential operative risks and the absence of any difference in patient-reported outcomes at 1yr.


Bone & Joint 360
Vol. 12, Issue 5 | Pages 39 - 42
1 Oct 2023

The October 2023 Oncology Roundup360 looks at: Are pathological fractures in patients with osteosarcoma associated with worse survival outcomes?; Spotting the difference: how secondary osteosarcoma manifests in retinoblastoma survivors versus conventional cases; Accuracy of MRI scans in predicting intra-articular joint involvement in high-grade sarcomas around the knee; Endoprosthetic reconstruction for lower extremity soft-tissue sarcomas with bone involvement; Local relapse of soft-tissue sarcoma of the extremities or trunk wall operated on with wide margins without radiation therapy; 3D-printed, custom-made prostheses in patients who had resection of tumours of the hand and foot; Long-term follow-up for low-grade chondrosarcoma; Evaluation of local recurrence and diagnostic discordance in chondrosarcoma patients undergoing preoperative biopsy; Radiological scoring and resection grade for intraosseous chondrosarcoma.


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1279 - 1280
1 Dec 2022
Haddad FS


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 220 - 220
1 Feb 2023
Bowditch M Eastwood DM


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 583 - 583
1 May 2023
Jennison T Ukoumunne O Lamb S Sharpe I Goldberg AJ


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 10 - 10
8 May 2024
Nanavati N Davies M Blundell C Flowers M Chadwick C Davies H
Full Access

Introduction

The current treatment for Freiberg's osteochondrosis centres around either: simple debridement or debridement osteotomy. The main principle of the osteotomy is to rotate normal articular cartilage into the affected area. We recommend the use of CT scanning to delineate the amount of available, unaffected cartilage available to rotate into the affected space.

Methods

We retrospectively reviewed 32 CT scans of new Freiberg's diagnoses in Sheffield over a 10 year period using the PACS system. We identified the sagittal CT slice that displayed the widest portion of proximal articular margin of the proximal phalanx and measured the diseased segment of the corresponding metatarsal head as an arc (in degrees). This arc segment was divided by 360°. This gave a ratio of the affected arc in the sagittal plane.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 25 - 25
8 May 2024
Parsons A Parsons S
Full Access

Background

Whereas arthroscopic arthrodesis of the ankle is commonplace and of the subtalar joint is established, reports of arthroscopic talo-navicular fusion are a rarity.

Aim

To review a case series to establish if arthroscopic talo-navicular arthrodesis is a feasible surgical option.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 17 - 17
8 May 2024
Senthi S Miller D Hepple S Harries W Winson I
Full Access

Tendoscopy in the treatment of peroneal tendon disorders is becoming an increasingly safe, reliable, and reproducible technique. Peroneal tendoscopy can be used as both an isolated procedure and as an adjacent procedure with other surgical techniques. The aim of our study was to review all peroneal tendoscopy that was undertaken at the AOC, by the senior authors (IGW, SH), and to determine the safety and efficacy of this surgical technique.

Methods

From 2000 to 2017 a manual and electronic database search was undertaken of all procedures by the senior authors. Peroneal tendoscopy cases were identified and then prospectively analysed.

Results

51 patients (23 male, 28 female) were identified from 2004–2017 using a manual and electronic database search. The mean age at time of surgery was 41.5 years (range 16–83) with a mean follow-up time post operatively of 11.8 months (range 9–64 months). The main indications for surgery were lateral and/or postero-lateral ankle pain and lateral ankle swelling. The majority of cases showed unstable peroneal tendon tears that were debrided safely using tendoscopy. Of the 51 patients, 23 required an adjacent foot and ankle operation at the same time, 5 open and 17 arthroscopic (12 ankle, 5 subtalar). Open procedures included 2 first ray osteotomies, 2 open debridements of accessory tissue, one PL to PB transfer. One patient also had an endoscopic FHL transfer. Complication rates to date have been low: 2 superficial wound infections (4%) and one repeat tendoscopy for ongoing pain. A small proportion of patients with ongoing pain were treated with USS guided steroid injections with good results.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 22 - 22
8 May 2024
Brookes M Kakwani R Townshend D Murty A
Full Access

Background

Traditionally, the extended lateral approach (ELA) was the favoured approch for calcaneal fractures, but has been reported to have high incidence of wound complications. There has been a move amongst surgeons in the United Kingdom towards the sinus tarsi approach (STA) due to its minimally invasive nature, attempting to reduce such complications.

Aims

To evaluate outcomes of ELA and STA for all consecutive calcaneal fracture fixation in our institution over a 10yr period.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 1 - 1
8 May 2024
Wiewiorski M Barg A Valderrabano V
Full Access

Introduction

Autologous Matrix Induced Chondrogenesis (AMIC) for surgical treatment of osteochondral lesions of the talus (OCLT) has shown excellent clinical and radiological results at short term follow up two years after surgery. However, no mid-term follow up data is available.

Aim

1. To evaluate the clinical outcome after AMIC-aided reconstruction of osteochondral lesions of the talus at a minimum follow up time of five years. 2. To evaluate the morphology and quality of the regenerated cartilage by magnetic resonance imaging (MRI) at on at a minimum follow up time of five years.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 4 - 4
8 May 2024
Nurm T Ramaskandhan J Nicolas A Siddique M
Full Access

Introduction

Total ankle arthroplasty (TAA) is an increasingly popular treatment option for patients with end-stage ankle arthritis. However, for most implant systems, failure rates of 10–20% have been reported within the first 10 years after primary TAA. Pain is the primary symptom that indicates failure of TAA but cause of it can be difficult to establish.

Methods

All patients who underwent a primary TAA at our center were included in the study. The clinical outcomes were studied for patients requiring a further revision procedure following primary TAA. The reasons for revision surgery and outcomes of surgery were analyzed using appropriate inferential statistical tests.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 23 - 23
8 May 2024
Jayatilaka M Fisher A Fisher L Molloy A Mason L
Full Access

Introduction

The treatment of posterior malleolar fractures is developing. Mason and Molloy (Foot Ankle Int. 2017 Nov;38(11):1229-1235) identified only 49% of posterior malleolar rotational pilon type fractures had syndesmotic instabilities. This was against general thinking that fixation of such a fragment would stabilize the syndesmosis.

Methods

We examined 10 cadaveric lower limbs that had been preserved for dissection at the Human Anatomy and Resource Centre at Liverpool University in a solution of formaldehyde. The lower limbs were carefully dissected to identify the ligamentous structures on the posterior aspect of the ankle. To compare the size to the rotational pilon posterior malleolar fracture (Mason and Molloy 2A and B) we gathered information from our posterior malleolar fracture database. 3D CT imaging was analysed using our department PACS system.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 23 - 23
10 May 2024
Leary J Lynskey T Muller A
Full Access

Objective

Carpal tunnel release surgery is a commonly performed procedure for alleviating symptoms of median nerve compression and restoring hand function. With pressure on theatre time these procedures are now commonly performed in a step-down out-patient facility under local anaesthetic. The choice of suture for skin closure in this procedure can impact the quality of wound healing, patient outcomes and the follow-up required however the question of the best type of suture remains unanswered. The purpose of this study was to compare the outcomes of absorbable and non-absorbable sutures using a randomised control trial design.

Methods

Eighty patients diagnosed with bilateral carpal tunnel syndrome were enrolled and underwent outpatient carpal tunnel release surgery under local anaesthetic in a staged fashion. Random number generation was used to assign each hand to receive interrupted nylon or Vicryl Rapide sutures. Pre-operative data collection included patient demographics, ASA, inflammatory conditions, smoking status as well as a Boston Carpal Tunnel Questionnaire (BCTQ) for each hand. Patients were followed up at 2 and 6 weeks after each operation and the BCTQ was repeated along with the Patient and Observer Scar Assessment Scale and the VAS score for wound discomfort. This study has approval from the DHB ethics committee, Local Iwi, HDC and ANZ Clinical Trials:ACTRN12623000100695.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 26 - 26
10 May 2024
Mauiliu S
Full Access

Titanium Elastic Nails have been around for the last 40 years, but it has never been introduced properly in the Pacific especially in Samoa in the management of femoral & in severely displaced forearm fractures in the paediatric age group & also Adult upper limb Trauma.

This paper looks at the cases treated in TTM Hospital (Apia, Samoa) from June 2019- June 2023, looking at common injury patterns, indications for fixation and the cost benefit to the family and hospital, in terms of early rehabilitation and improving the length of stay in hospital pre-Tens nail era from 6–8 weeks to 1–2 weeks in hospital. 29 cases were treated with TENs concept during this period, 17 femoral fractures, 10 forearm fractures & 1 humerus fracture.

Lastly this is very useful skill and tool to have in every hospital in the Pacific Islands, through proper training to prevent long term complications.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 39 - 39
10 May 2024
Zhu M Taylor G Mayo C Young S Mutu-Grigg J Poutawera V
Full Access

Aims

Hip fracture is a common injury in the elderly. Recent studies in orthopaedic access have demonstrated inequities affecting Māori. This study aimed to compare the demographic differences between Māori and NZ Europeans with hip fractures, identify any deficiencies in initial, surgical and post op care and in outcomes.

Methods

All cases in New Zealand from 2018–2020 were included. Key outcomes included time to theatre from admission, change in walking status, residential status and survival at 120 days post fracture.

Univariate analysis compared differences in demographics, surgical and management factors between ethnicities. Key outcome comparisons were conducted using multivariate analysis to assess whether ethnicity was an independent risk factor for outcomes.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 40 - 40
10 May 2024
Zhang J Miller R Chuang T
Full Access

Introduction

Distal femur fractures have traditionally been stabilized with either lateral locking plate or retrograde intramedullary nail. Dual-plates and nail-plate combination fixation have the theoretical biomechanical advantage, faster union and allows patients to weight bear immediately.

The aim of this study is to compare single vs combination fixation, and evaluate outcomes and complications.

Method

We retrospectively reviewed all patients over 60, admitted to Christchurch Hospital, between 1st Jan 2016 and 31st Dec 2022, with an AO 33A/33B/33C distal femur fracture. Patient demographics, fracture characteristics, operation details, and follow up data were recorded.

Primary outcomes are union rate, ambulatory status at discharge, and surgical complications. Secondary outcomes include quality of reduction, operation time and rate of blood transfusions.


Introduction

The first VRAS TKA was performed in New Zealand in November 2020 using a Patient Specific Balanced Technique whereby VRAS enables very accurate collection of the bony anatomy and soft tissue envelope of the knee to plan and execute the optimal positioning for a balanced TKA

Method

The first 45 VRAS patients with idiopathic osteoarthritis of the knee was compared with 45 sequential patients who underwent the same TKA surgical technique using Brainlab 3 which the author has used exclusively in over 1500 patients. One and two year outcome data will be presented


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 2 - 2
10 May 2024
Chen W Tay ML Bolam S Rosser K Monk AP Young SW
Full Access

Introduction

A key outcome measured by national joint registries are revision events. This informs best practice and identifies poor-performing surgical devices. Although registry data often record reasons for revision arthroplasty, interpretation is limited by lack of standardised definitions of revision reasons and objective assessment of radiologic and laboratory parameters. Our study aim was to compare reasons for unicompartmental knee arthroplasty (UKA) revision reported to the New Zealand Joint Registry (NZJR) with reasons identified by independent clinical review.

Methods

A total of 2,272 patients undergoing primary medial and lateral UKA at four large tertiary hospitals between 2000 and 2017 were included. A total of 158 patients underwent subsequent revision with mean follow-up of 8 years. A systematic review of clinical findings, radiographs and operative data was performed to identify revision cases and to determine the reasons for revision using a standardised protocol. These were compared to reasons reported to the NZJR using Chi-squared and Fisher exact tests.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 9 - 9
10 May 2024
Owen D
Full Access

Background

Increasing evidence suggests a link between the bearing surface used in total hip arthroplasty (THA) and the occurrence of infection. It is postulated that polyethylene has immunomodulatory effects and may influence bacterial function and survival, thereby impacting the development of periprosthetic joint infection (PJI). This study aimed to investigate the association between polyethylene type and revision surgery for PJI in THA using data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR). We hypothesized that the use of XLPE would demonstrate a statistically significant reduction in revision rates due to PJI compared to N-XLPE.

Methods

Data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) spanning September 1, 1999, to December 31, 2021, were used to compare the infection revision rates between THA using N-XLPE and XLPE. We calculated the Cumulative Percentage Revision rate (CPR) and Hazard Ratio (HR) while controlling for factors like age, sex, body mass index (BMI), American Society of Anesthesiologists’ (ASA) grade, and head size.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 8 - 8
10 May 2024
Sim K Schluter D Sharp R
Full Access

Introduction

Acetabular component loosening with associated bone loss is a challenge in revision hip arthroplasty. Trabecular Metal (TM) by Zimmer Biomet has been shown to have greater implant survivorship for all-cause acetabular revision in small cohort retrospective studies. Our study aims to review outcomes of acetabular TM implants locally.

Method

This is a retrospective observational study using data from Auckland City and North Shore Hospitals from 1st of January 2010 to 31st of December 2020. Primary outcome is implant survivorship (re-revision acetabular surgery for any cause) demonstrated using Kaplan-Meier analysis. Secondary outcome is indication for index revision and re-revision surgery. Multivariate analysis used to identify statistically significant factors for re-revision surgery.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 18 - 18
10 May 2024
Joseph R Callon K Lin J Matthews B Irwin S Williams D Ashton N Crawford H Wen J Swift S Cornish J
Full Access

Introduction

Major trauma during military conflicts involve heavily contaminated open fractures. Staphylococcus aureus (S. aureus) commonly causes infection within a protective biofilm. Lactoferrin (Lf), a natural milk glycoprotein, chelates iron and releases bacteria from biofilms, complimenting antibiotics. This research developed a periprosthetic biofilm infection model in rodents to test an Lf based lavage/sustained local release formulation embedded in Stimulin beads.

Method

Surgery was performed on adult rats and received systemic Flucloxacillin (Flu). The craniomedial tibia was exposed, drilled, then inoculated with S. aureus biofilm. A metal pin was placed within the medullary cavity and treatments conducted. Lf in lavage solutions: The defect was subject to 2× 50 mL lavage with 4 treatment groups (saline only, Lf only, Bactisure with Lf, Bactisure with saline). Lf embedded in Stimulin beads: 4 bead types were introduced (Stimulin only, Lf only, Flu only, Lf with Flu). At day 7, rats are processed for bioluminescent and X-ray imaging, and tibial explants/pins collected for bacterial enumeration (CFU).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 29 - 29
10 May 2024
Stowers M Rahardja R Nicholson L Svirskis D Hannam J Young S
Full Access

Introduction

Day stay surgery for anterior cruciate ligament (ACL) reconstructions is an increasingly common practice and has driven clinicians to come up with postoperative pain regimes that allow same day mobilisation and a safe and timely discharge. There is a paucity of literature surrounding the use of intraosseous (IO) ropivacaine used as a Bier's block to provide both intraoperative and postoperative analgesia in lower limb surgery.

Methods

This patient blinded, pilot study randomised 15 patients undergoing ACL reconstruction to receive either IO ropivacaine 1.5 or 2.0 mg/kg; or 300 mg of ropivacaine as local infiltration (standard of care). Toxic plasma levels of ropivacaine have been defined in the literature and therefore the primary outcome for this study was arterial plasma concentration of ropivacaine as a means to determine its safety profile. Samples were taken via an arterial line at prespecified times after tourniquet deflation. Secondary outcomes that we were interested in included immediate postoperative pain scores using the visual analogue scale (VAS) and perioperative opioid equivalent consumption.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 31 - 31
10 May 2024
Clatworthy M Rahardja R Young S Love H
Full Access

Background

Anterior cruciate ligament (ACL) reconstruction with concomitant meniscal injury occurs frequently. Meniscal repair is associated with improved long-term outcomes compared to resection but is also associated with a higher reoperation rate. Knowledge of the risk factors for repair failure may be important in optimizing patient outcomes.

Purpose

This study aimed to identify the patient and surgical risk factors for meniscal repair failure, defined as a subsequent meniscectomy, following concurrent primary ACL reconstruction.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 36 - 36
10 May 2024
Bolam SM Matheson N Douglas M Anderson K Weggerty S Londahl M Gwynne-Jones D Navarre P
Full Access

Introduction

The Te Whatu Ora Southern catchment area covers the largest geographical region in New Zealand (over 62,000 km2) creating logistical challenges in providing timely access to emergency neck of femur (NOF) fracture surgery. Current Australian and New Zealand guidelines recommend that NoF surgery be performed within 48 hours of presentation. The purpose of this study was to compare the outcomes for patients with NoF fractures who present directly to a referral hospital (Southland Hospital) compared to those are transferred from rural peripheral centres.

Methods

A retrospective cohort study identified 79 patients with NoF who were transferred from rural peripheral centres to a referral hospital for operative management between January 2011 to December 2020. This cohort was matched 1:1 by age and sex to patients with NoF who presently directly to the referral hospital over the same period. The primary outcome was to compare time to surgery between the groups and secondary outcomes were to compare length of hospital stay, complication rates and mortality rates at 30-days and 1-year.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 12 - 12
10 May 2024
Sevic A Patel C Tomlinson M
Full Access

Introduction

Comparative studies examining Fixed-Bearing (FB) and Mobile-Bearing (MB) Total Ankle Replacement (TAR) designs have demonstrated similar results and successful long-term outcomes for both. To date there has been no study directly comparing FB and MB designs of the same prosthesis. We present the first prospective randomised trial comparing patient satisfaction, functional outcomes and radiographic results of the Salto Talaris Fixed-Bearing and the Salto Mobile-Bearing Total Ankle Replacement in the treatment of end-stage ankle arthritis.

Methods

A total of 108 adult patients with end-stage ankle arthritis were enrolled in the study between November 2014 and October 2021 with similar demographic comparison. Prospective patient-reported outcomes and standardised weightbearing ankle radiographs were performed preoperatively, at 6 weeks, 6 months and 12 months post-operatively, followed by yearly intervals. All surgeries were performed by a single non-design orthopaedic foot and ankle specialist with experience in over 200 Salto and Salto Talaris TAR prior to the study. Radiographs were examined independently by two clinicians. Complete patient data and radiographs were available for 103 patients with an average follow up of 2 years.


Bone & Joint 360
Vol. 13, Issue 1 | Pages 35 - 38
1 Feb 2024

The February 2024 Oncology Roundup360 looks at: Does primary tumour resection improve survival for patients with sarcomas of the pelvis with metastasis at diagnosis?; Proximal femur replacements for an oncologic indication offer a durable endoprosthetic reconstruction option: a 40-year experience; The importance of awaiting biopsy results in solitary pathological proximal femoral fractures: do we need to biopsy solitary pathological fractures?; Effect of radiotherapy on local recurrence, distant metastasis, and overall survival in 1,200 extremity soft-tissue sarcoma patients; What to choose in bone tumour resections? Patient-specific instrumentation versus surgical navigation; Optimal timing of re-excision in synovial sarcoma patients: immediate intervention versus waiting for local recurrence; Survival differences of patients with resected extraskeletal osteosarcoma receiving two different (neo) adjuvant chemotherapy regimens; Solitary versus multiple bone metastases in the appendicular skeleton: should the surgical treatment be different?.


Bone & Joint 360
Vol. 13, Issue 1 | Pages 38 - 41
1 Feb 2024

The February 2024 Children’s orthopaedics Roundup360 looks at: Hip impingement after in situ pinning causes decreased flexion and forced external rotation in flexion on 3D-CT; Triplane ankle fracture patterns in paediatric patients; Improved forearm rotation even after early conversion to below-elbow; Selective dorsal rhizotomy and cerebral palsy (CP) hip displacement; Abduction bracing following anterior open reduction for developmental dysplasia of the hip does not improve residual dysplasia or reduce secondary surgery; 40% risk of later total hip arthroplasty for in situ slipped capital femoral epiphysis (SCFE) pinning; Does brace treatment following closed reduction of developmental dysplasia of the hip improve acetabular coverage?; Waterproof hip spica casts for paediatric femur fractures.


Bone & Joint 360
Vol. 13, Issue 1 | Pages 46 - 46
1 Feb 2024


Bone & Joint 360
Vol. 12, Issue 3 | Pages 16 - 18
1 Jun 2023

The June 2023 Knee Roundup360 looks at: Cementless total knee arthroplasty is associated with early aseptic loosening in a large national database; Is cementless total knee arthroplasty safe in females aged over 75 years?; Could novel radiological findings help identify aseptic tibial loosening?; The Attune cementless versus LCS arthroplasty at introduction; Return to work following total knee arthroplasty and unicompartmental knee arthroplasty; Complications and downsides of the robotic total knee arthroplasty; Mid-flexion instability in kinematic alignment better with posterior-stabilized and medial-stabilized implants?; Patellar resurfacing does not improve outcomes in modern knees.


Bone & Joint 360
Vol. 12, Issue 6 | Pages 42 - 45
1 Dec 2023

The December 2023 Children’s orthopaedics Roundup360 looks at: A comprehensive nonoperative treatment protocol for developmental dysplasia of the hip in infants; How common are refractures in childhood?; Femoral nailing for paediatric femoral shaft fracture in children aged eight to ten years; Who benefits from allowing the physis to grow in slipped capital femoral epiphysis?; Paediatric patients with an extremity bone tumour: a secondary analysis of the PARITY trial data; Split tibial tendon transfers in cerebral palsy equinovarus foot deformities; Liposomal bupivacaine nerve block: an answer to opioid use?; Correction with distal femoral transphyseal screws in hemiepiphysiodesis for coronal-plane knee deformity.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 8 - 8
23 Apr 2024
Senan R Linkogel W Marwan Y Staniland T Sharma H
Full Access

Introduction

Knee arthrodesis is a useful limb salvage technique to maintain function in patients with complex and infected total knee arthroplasties (TKA). There are a number of commonly used external fixators, but no consensus on which of these are optimal.

The aim of this study was to synthesise the current literature to guide clinical decision making and improve patient outcomes. We systematically review the literature to compare outcomes of external fixators in arthrodesis following infected TKA.

Materials & Methods

A systematic review of the literature of primary research articles investigating the use of external fixators for knee arthrodesis after an infected TKA was conducted. Relevant articles were identified with a search strategy on online databases (EMBASE and Medline) and reviewed by two independent reviewers.

Clinical outcome measures were independently extracted by two reviewers which included union rate, infection eradication rate, complication rate, time to fusion, and time in frame.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 29 - 29
23 Apr 2024
Ahmed T Upadhyay P Menawy ZE Kumar V Jayadeep J Chappell M Siddique A Shoaib A
Full Access

Introduction

Knee dislocations, vascular injuries and floating knee injuries can be initially managed by a external fixator. Fixator design constructs include the AO pattern and the Diamond pattern. However, these traditional constructs do not adhere to basic principles of external fixation. The Manchester pattern knee-spanning external fixator is a new construct pattern, which uses beam loading and multiplanar fixation. There is no data on any construct pattern. This study compares the stability of these designs.

Materials & Methods

Hoffman III (Stryker, USA) external fixation constructs were applied to articulated models of the lower limb, spanning the knee with a diamond pattern and a Manchester pattern. The stiffness was loaded both statically and cyclically with a Bose 3510 Electroforce mechanical testing jig (TA Instruments). A ramp to load test was performed initially and cyclical loading for measurement of stiffness over the test period. The results were analysed with a paired t-test and ANOVA.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 27 - 27
23 Apr 2024
Howard A Harwood P Benton A Merrel C Culmer P Bolton W Stewart T
Full Access

Introduction

Ilizarov fixators are reliant on tensioned fine wires for stability. The tension in the wires is generated using specific tensioning devices. Loss of wire tension over time may lead of loss a stability and complications. A series of in vitro experiments were undertaken to explore wire tensioner accuracy, the impact of fixation bolt torque and initial tension on loss of tension in ilizarov constructs under static and dynamic loads.

Materials & Methods

Medical grade materials were applied to a synthetic bone analogue using surgical instruments in all experiments. Bolt torque was fixed at 6, 10 or 14 Nm using a torque limiting wrench. Wire tension was assessed using a strain measurement bridge. Wires were tensioned to 90, 110 and 130kg as measured by a commercial dynamometric tensioner. Static and dynamic testing was undertaken using an instron testing machine. Cyclical loads from 50–750N were applied for 5000 cycles.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 13 - 13
23 Apr 2024
Lister J McDaid C Hewitt C Leggett H James S Sharma H
Full Access

Introduction

There are concerns that patient-reported outcome measures (PROMs) currently used for adults requiring, undergoing or after undergoing lower limb reconstruction (LLR) are not adequately capturing the range of experiences important to these patients. The ‘Patient-Reported Outcome Measure for Lower Limb Reconstruction’ (PROLLIT) study developed a conceptual framework of outcomes identified as important and relevant by adult LLR patients. This review explored whether existing PROMs address these outcomes, and exhibit content validity in this population.

Materials & Methods

A range of key PROMs was selected (n=32). Systematic and hand-searches were employed to find studies assessing content validity of these PROMs in the adult LLR population, along with PROM content and development information. A systematic review of content validity of the measures was carried out following ‘COnsensus-based Standards for the selection of health Measurement Instruments’ (COSMIN) guidance, alongside conceptual mapping of the content of the PROMs against the PROLLIT conceptual framework.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 6 - 6
23 Apr 2024
Mistry D Rahman U Khatri C Carlos W Stephens A Riemer B Ward J
Full Access

Introduction

Continuous compression implants (CCIs) are small memory alloy bone staples that can provide continuous compression across a fracture site, which change shape due to temperature changes. Reviews of CCIs in orthopaedics have documented their use in mainly foot and ankle surgery, with very limited descriptions in trauma. They could be beneficial in the management of complex or open injuries due to their low profile and quick insertion time. The aim of this case series were to clarify the use of CCIs in modern day limb reconstruction practice.

Materials & Methods

This was a single centred study looking retrospectively at prospective data for patients who were treated for an acute fracture or non-union with a CCI between September 2019 and May 2023. Primary outcome was to determine the function and indication of the CCI as judged retrospectively and secondary outcomes investigated unplanned returns to theatre for infection or CCI failure.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 17 - 17
23 Apr 2024
Mackarel C Tunbridge R
Full Access

Introduction

Sheffield Children's Hospital specialises in limb lengthening for children. Soft tissue contracture and loss of range of motion at the knee and ankle are common complications. This review aims to look at therapeutic techniques used by the therapy team to manage these issues.

Materials & Methods

A retrospective case review of therapy notes was performed of femoral and tibial lengthening's over the last 3 years. Included were children having long bone lengthening with an iIntramedullary nail, circular frame or mono-lateral rail. Patients excluded were any external fixators crossing the knee/ankle joints.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 15 - 15
23 Apr 2024
Sharkey S Round J Britten S
Full Access

Introduction

Compartment syndrome can be a life changing consequence of injury to a limb. If not diagnosed and treated early it can lead to permanent disability. Neurovascular observations done on the ward by nursing staff, are often our early warning system to those developing compartment syndrome. But are these adequate for detecting the early signs of compartment syndrome? Our aim was to compare the quality and variability of charts across the UK major trauma network.

Materials & Methods

All major trauma centres in England and Scotland were invited to supply a copy of the neurovascular chart routinely used. We assessed how such charts record relevant information. Specific primary data points included were pain scores, analgesia requirements, pain on passive stretch and decreased sensation in the first web space specifically. As secondary objectives, we assessed how late signs were recorded, whether clear instructions were included, quantitative scores and the use of regional blocks recorded.


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1362 - 1368
1 Dec 2022
Rashid F Mahmood A Hawkes DH Harrison WJ

Aims

Prior to the availability of vaccines, mortality for hip fracture patients with concomitant COVID-19 infection was three times higher than pre-pandemic rates. The primary aim of this study was to determine the 30-day mortality rate of hip fracture patients in the post-vaccine era.

Methods

A multicentre observational study was carried out at 19 NHS Trusts in England. The study period for the data collection was 1 February 2021 until 28 February 2022, with mortality tracing until 28 March 2022. Data collection included demographic details, data points to calculate the Nottingham Hip Fracture Score, COVID-19 status, 30-day mortality, and vaccination status.


Bone & Joint 360
Vol. 13, Issue 1 | Pages 22 - 26
1 Feb 2024

The February 2024 Wrist & Hand Roundup360 looks at: Occupational therapy for thumb carpometacarpal osteoarthritis?; Age and patient-reported benefits from operative management of intra-articular distal radius fractures: a meta-regression analysis; Long-term outcomes of nonsurgical treatment of thumb carpometacarpal osteoarthritis: a cohort study; Semi-occlusive dressing versus surgery in fingertip injuries: a randomized controlled trial; Re-fracture in partial union of the scaphoid waist?; The WALANT distal radius fracture: a systematic review; Endoscopic carpal tunnel release with or without hand therapy?; Ten-year trends in the level of evidence in hand surgery.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 47 - 47
2 May 2024
Kolhe S Khanduja V Malviya A
Full Access

Hip arthroscopy (HA) is an effective treatment for various hip conditions but has a steep learning curve and its effect on long-term joint preservation is unclear. This study uses population-level data to assess (1) the 90-day complication rate, and (2) the frequency and timing of revision HA, total hip replacement (THR), and pelvic osteotomy (PO) following primary HA.

We performed a retrospective analysis of the National Hospital Episode Statistics database, examining all patients who underwent primary HA in NHS hospitals in England from 2010 to 2023 using relevant OPCS-4 codes. We evaluated patient demographics, 90-day complications, and reoperation rates for revision HA, THR, and PO. Descriptive statistical analyses were performed to calculate frequencies and average time to reoperations.

We included 22,401 HA procedures in the study. The mean LOS was 0.82±2.04 days. The 90-day readmission rate was 0.17% at a mean of 54.4±8.1 days. The most common reasons for readmission were reoperation (0.071%), followed by infection (0.031%), pulmonary embolism (0.027%), pain (0.022%), bleeding (0.018%), and deep vein thrombosis (0.004%). One patient died within 90 days.

Overall, 4942 patients (22.1%) required further surgery at a mean of 2.71±2.27 years. The rates of revision HA, conversion to THR, and PO were 6.94%, 14.6%, and 0.50% at a mean of 2.39±1.79, 2.87±2.46, and 2.26±1.80 years respectively. Female patients had higher rates of reoperation than males for conversion to THR (9.99% vs 4.63%), revision HA (4.92% vs 2.02%), and subsequent PO (0.43% vs. 0.06%) (p<0.001).

This study demonstrates a low short-term complication rate after primary HA, supporting existing literature. However, a large proportion of patients required further surgery, especially females. These findings highlight the need for careful patient selection and counselling before HA to optimise outcomes, as well as further research on factors influencing longer-term outcomes and cost-effectiveness.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 62 - 62
2 May 2024
Afzal S Sephton B Wilkinson H Hodhody G Ammori M Kennedy J Hoggett L Board T
Full Access

Total Hip Arthroplasty (THA) and Hip Hemiarthroplasties (HA) are successful, cost-effective procedures that improve quality of life. Dislocation is a well recognised complication with a significant health and economic burden. We aim to establish the current management practices across the United Kingdom (UK) for Prosthetic Hip Dislocations (PHD). Our definition of a PHD includes; THA, HA and revision THA.

This national study builds on our regional pilot study and records one of the largest datasets of Prosthetic Hip Dislocation management within the UK.

A trainee-led collaborative; the North West Orthopaedic Research Collaborative (NWORC). Conducted a retrospective audit, registered as Quality Improvement (QI) projects, collected data from 38 hospital trusts across the UK.

Data was collected on patient-related factors, inpatient management, and outpatient follow up of each PHD episode between January and July 2019. Primary outcome measured definitive management, in the form of revision surgery or the consideration for this through a referral pathway.

A total of 673 (THA 504, Revision THA 141, HA 28) patients were included with a total of 740 dislocation episodes. Mean age was 75.6 years with female to male ratio 2:1. The majority of PHDs were a result of a low energy mechanism (98.7%) and presented over 6 months post index procedure (80.5%). Over half (53.8%) attended with a first or second time dislocation. Only 29.9% patients received onward revision referral; whereas 70.1% followed diverse management patterns, including local non-arthroplasty and primary arthroplasty surgeon follow-ups. Revision THAs had higher rates of referral for revision (p<0.001) compared to primary THA and HA dislocations.

A high number of PHDs present across the UK, with under a third receiving definitive management plans. This variation increases the economical burden to the National Health Service, highlighting the need for national guidance to manage these complex patients.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 2 - 2
2 May 2024
Gunn C Thakker V Jones HW Barrow J
Full Access

Ceramic bearing fracture is a rare complication following implantation using modern day ceramic bearing materials. Revision bearing options in such cases is debated, with the choice between ceramic-on-ceramic and ceramic-on-polyethylene bearings. Revision to a hard on soft bearing raises concerns about potential catastrophic wear secondary to a third-body reaction caused by the fractured ceramic particles.

Data was collected retrospectively from the NJR, electronic patient records, revision database and picture archiving and communication system. Templating software was used to determine linear wear between first post-operative radiograph and the latest available follow up. Univariate analysis was used to examine patient demographics and the wear rates for revision of ceramic bearing fractures to ceramic on polyethylene components. The intra and inter-rater reliability of wear measurements was calculated.

There were twelve patients identified as meeting the inclusion criteria. The average age at revision was 62 years (54–72). There were 6 liner and 6 head fractures revised to delta ceramic heads and cross-linked polyethylene acetabular components. The most frequently used head size was 32mm. At mean follow up of 3.8 years (0.5 6.1 years), median 4.4 years, linear wear rate was calculated at 0.08± 0.06 mm/year. Both intra-rater and inter-rater reliability was excellent with ICC scores of 0.99 at all timepoints.

Revision to ceramic on polyethylene (CoP) bearings following ceramic fracture does not cause early catastrophic wear at early follow up. It appears safe to use this hard on soft bearing combination, given that wear rates are comparable to what is expected in a primary hip replacement setting. Longer follow up is required to establish if this trend persists.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 1 - 1
2 May 2024
Mayne A Saad A Botchu R Politis A Wall P McBryde C
Full Access

Radiological investigations are essential in the work-up of patients presenting with non-arthritic hip pain, to allow close review of the complex anatomy around the hip and proximal femur. The aim of this study is to quantify the radiation exposure associated with common radiological investigations performed in assessing young adult patients presenting with non-arthritic hip pain.

A retrospective review of our UK tertiary hip preservation centre institutional imaging database was performed. Data was obtained for antero-posterior, cross-table lateral and frog-lateral radiographs, along with data for the low dose CT hip protocol and the Mako CT Hip protocol. The radiation dose of each imaging technique was measured in terms of dose-area product (DAP) with units of mGycm2, and the effective doses (ED, mSv) calculated.

The mean effective radiation dose for hip radiographs was in the range 0.03 to 0.83mSv (mean DLP 126.7–156.2 mGycm2). The mean effective dose associated with the low-dose CT hip protocol was 3.04mSv (416.8 mGycm2) and for the Stryker Mako CT Hip protocol was 8.4mSv (1061 mGycm2). The radiation dose associated with use of CT imaging was significantly greater than plain radiographs (p<0.005)

Investigation of non-arthritic hip pain can lead to significant ionising radiation exposure for patients. In our institution, the routine protocol is to obtain an anteroposterior radiograph and then a specific hip sequence 3 Tesla MRI including anteversion views. This provides the necessary information in the majority of cases, with CT scanning reserved for more complex cases where we feel there is a specific indication. We would encourage the hip preservation community to carefully consider and review the use of ionising radiation investigations.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 43 - 43
2 May 2024
Martin R Fishley W Kingman A Carluke I Kramer D Partington P Reed M Petheram T
Full Access

Periprosthetic joint infection is a serious complication of primary total hip replacement (THR) with significant associated morbidity. In acute infection, Debridement, Antibiotics and Implant Retention (DAIR) may be considered. Current national guidelines recommend a DAIR should be performed by “an experienced arthroplasty surgeon┕ but do not specify the need for this to be a revision arthroplasty surgeon. We investigated outcomes in our NHS Trust of DAIR procedures performed by revision and non-revision arthroplasty surgeons.

Infection registry data and patient records were analysed for all DAIR procedures of infected primary THRs between 2017 and 2021. Data collected included details of the primary surgery, the presentation with infection, the DAIR procedure and any subsequent complications including return to theatre at any time point. Routinely collected pre- and post-operative patient reported outcome measures (PROMs) were reviewed.

54 periprosthetic joint infections of primary THRs received a DAIR procedure. 41 DAIRs were performed by a revision surgeon and 13 by non-revision surgeons. There was no significant difference in time from primary THR to presentation with infection, time from presentation to DAIR or pre-operative C-reactive protein between the two groups.

In 21 (38.9%) patients the DAIR procedure was classed as a treatment failure; 17 patients (31.5%) returned to theatre for further revision surgery, one (2.4%) died related to infection and three (5.6%) had persistent infection but did not receive further surgery. Treatment failure was significantly higher in the non-revision surgeon group (9/13 (69.2%)) than in the revision surgeon group (12/41 (29.3%)) (p = 0.02). Overall, improvement in PROMs after DAIR was seen at both six and 12 months.

The overall success rate of DAIR was 61.1% and there was a sustained improvement in PROMs after surgery. However, there was a significant difference in failure rates between revision surgeons and non-revision surgeons.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 52 - 52
2 May 2024
Bayram JM Wickramasinghe N Scott CE Clement ND
Full Access

The aims were to assess whether preoperative joint-specific function (JSF) and health-related quality of life (HRQoL) were associated with level of clinical frailty in patients waiting for a primary total hip arthroplasty (THA) or knee arthroplasty (KA).

Patients waiting for a THA (n=100) or KA (n=100) for more than six months were prospectively recruited from the study centre. Overall, 162 patients responded to the questionnaire (81 THA; 81 KA). Patient demographics, Oxford score, EuroQol five dimension (EQ-5D) score, EuroQol visual analogue score (EQ-VAS), Rockwood Clinical Frailty Score (CFS), and time spent on the waiting list were collected.

There was a significant correlation between CFS and the Oxford score (THA r=ˆ’0.838; p<0.001, KA r=ˆ’0.867; p<0.001), EQ-5D index (THA r=ˆ’0.663, p<0.001; KA r=ˆ’0.681; p< 0.001), and EQ-VAS (THA r=ˆ’0.414; p<0.001, KA r=ˆ’0.386; p<0.001). Confounding variables (demographics and waiting time) where adjusted for using multiple regression analysis. For each 8.5 (THA, 95% CI 7.1 to 10.0; p<0.001) and 9.9 (KA, 95% CI 8.4 to 11.4; p<0.001) point change in the Oxford score, there was an associated change in level of the CFS. For each 0.16 (THA, 95% CI 0.10 to 0.22; p<0.001) and 0.20 (KA, 95% CI 0.12 to 0.27; p<0.001) utility change in EQ-5D, there was an associated change in level of the CFS. EQ-VAS (THA, B=ˆ’11.5; p<0.001, KA B=ˆ’7.9; p=0.005) was also associated with CFS.

JSF and HRQoL in patients awaiting THA or KA for more than six months, were independently associated with level of clinical frailty. With further prospective studies, clinical frailty may prove to be a useful metric to assist in the prioritization of arthroplasty waiting lists.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 29 - 29
2 May 2024
Gibbs V Champaneria R Sandercock J Welton N Geneen L Brunskill S Doree C Kimber C Palmer A Estcourt L
Full Access

Preoperative anaemia and intraoperative blood loss result in ∼90% of individuals being anaemic following hip and knee arthroplasty. Reducing blood loss offers the opportunity to improve outcomes and reduce the risk of transfusion and costs. This review's aim was to determine the effectiveness of drugs for preventing blood loss, and identify optimal dose, route, and timing of administration.

Cochrane network meta-analysis of randomised controlled trials was conducted. Inclusion criteria: adults undergoing primary or revision elective hip or knee arthroplasty. Drugs studied: tranexamic acid (TXA), aprotinin, epsilon-aminocaproic acid, desmopressin, factor VIIa and XIII, fibrinogen, fibrin sealants, and non-fibrin sealants. Primary outcomes: need for allogenic blood transfusion, all• cause mortality (within 30 days). Secondary outcomes: mean number of transfusion episodes, re-operation, length of hospital stay and adverse events (DVT, PE, CVA, MI).

102 studies with 8418 participants. Trials included more women (63%). 47 studies (4398 participants) were included within the blood transfusion NMA. TXA given intra-articularly and orally at a total dose of greater than 3g pre-incision, intraoperatively and postoperatively ranked the highest, with anticipated absolute effect of 147 fewer transfusions per 1000 (53% chance ranking 1st) (relative risk(RR) 0.02, 95% credible interval(CrI) 0–0.31); moderate-certainty). Aprotinin (RR 0.59, 95%:CrI 0.36–0.86; low certainty evidence), fibrin (RR 0.86, CrI 0.25–2.93; very-low certainty) and EACA (RR 0.60, 95%:CrI 0.29–1.27; very-low certainty) were not shown to be as effective as TXA.

TXA was the most effective drug for preventing bleeding in lower limb arthroplasty. Aprotinin and EACA were not as effective. Currently, the optimal dose, route and timing of administration of TXA is unclear. However, TXA given at higher doses and via mixed routes ranked higher in the treatment hierarchy. Oral TXA may be as effective as intavenous. There was no evidence of harm associated with higher doses of TXA.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 30 - 30
2 May 2024
Dhesi E Salih S Tomlinson R Salih S
Full Access

Polymethylmethacrylate (PMMA) bone cement is strong in compression, however it tends to fail under torsion. Sufficient pressurisation and subsequent interdigitation between cement and bone are critical for the mechanical interlock of cemented orthopaedic implants, and an irregular surface on the acetabular cup is necessary for reasonable fixation at the cup-cement interface. There is limited literature investigating discrepancies in the failure mechanisms of cemented all-polyethylene acetabular cups with and without cement spacers, under torsional loading.

In vitro experimental comparison of three groups of polyethylene acetabular prosthesis (PAP) cemented into prepared sawbone hemipelvises:

* PAP without PMMA spacers maintaining an equal cement mantle circumferentially. (Group 1 n=3)

* PAP without PMMA spacers cemented deliberately ‘bottoming-out’ the implant within the acetabulum. (Group 2 n=3)

* PAP with PMMA spacers. (Group 3 n=3)

The constructs were tested to torstional failure on a custom designed setup, and statistical analysis done by a one-way ANOVA and Tukey-Welsh test.

Group 3 demonstrated superior torsional resistance with a statistically significant torque of 145Nm (SD±12Nm) at failure, compared to group 2 (109Nm, SD±7Nm) and group 1 (99Nm, SD±8Nm). Group 3 experienced failure predominantly at the bone-cement interface, in contrast, Groups 1 and 2 exhibited failure predominantly at the cup-cement interface. There was no significant difference between Group 1 and 2. Qualitative analysis of the failure mode indicates the efficient redistribution of stress throughout the cement mantle, consistent with the greater uniformity of cement.

PMMA spacers increase the resistance to torsional failure at the implant-cement interface. Acetabular components without spacers (Groups 1 and 2) failed at the implant-cement interface before the cement-bone interface, at a statistically significantly lower level of torque to failure. Although the PMMA spacers may reduce cement interdigitation at the cement-bone interface the torsional forces required to fail are likely supraphysiological.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 45 - 45
2 May 2024
Mahmoud MA Sharkawy E Kamel M Metwaly S Said H Noaman S
Full Access

The postoperative pain after hip arthroscopy remains a major challenge in the immediate postoperative period. Adequate postoperative analgesia has been associated with increased patient satisfaction and decreased consumption of opioids. We evaluated the efficacy of pericapsular nerve group block (PENG) versus fascia iliaca block (FIB) in reducing post-operative pain and analgesic consumption within the first 24 hours following arthroscopic management of femoroacetabular impingement (FAI).

Thirty-nine patients (17 females and 25 males, ages 18–42 years, mean ± SD (27.9 ± 6.2), and mean BMI of 25.13±5.08 kg/m2 were scheduled for primary arthroscopic management of FAI. Included patients were randomized into two groups according to the block used in each. Group (A) 19 patients were included and had FIB and group (B) 20 patients were included and received PENG block. The efficacy of both techniques was clinically and statistically valuated using VAS score and quadriceps muscle power.

There was a statically significance difference in the mean at rest between the two groups at all measured time points following surgery (6, 12, 18 and 24 h). Also, in dynamic pain scores (with hip flexion) scores were statistically significant at 24 hours post-operative (P = .001). Total opioid consumption in the first 24 hours postoperative was lower in the PENG group with significant difference of mean 16.5 ±9.9 mg for PENG group versus 27.5±9.6 mg for FIB group (P < .005). Five patients (26.31%) in FIB group had weaker quadriceps muscle power while none in PENG group patients had quadriceps weakness.

PENG block might be considered as an ideal regional anesthesia modality for hip arthroscopy. As an alternative to more conventional regional nerve blocks such as a fascia iliaca block. PENG block is easily performed in the preoperative setting, and appears to spare motor function while providing a prolonged sensory pain relief.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 16 - 16
2 May 2024
McCann C Brunt A Walmsley P Akhtar A
Full Access

There is an increasing demand worldwide for total hip arthroplasty in patients over 80 years old. This study is the largest of its kind reporting long term outcomes and clinical survivorship of patients over 80 years old undergoing THR.

13171 patients 80 years or older who underwent THR between 2000 and 2019 were included. Demographic and operative data was collected including age, sex, laterality, date of surgery and operative technique. Presence and date of complications were collected. Data was also collected for the same time period on 80910 patients aged 51–79 years undergoing THR for comparison.

4103 (31.2%) male and 9068 female (68.8%) patients were included in the 80year old cohort. Median age was 83 (IQR 81–83, range 80–98). 32682 (40.4%) male and 48227 (59.6%) females were included in the 50–79year old cohort. Median age was 68 (IQR 62–73, range 50–79).

The 80 cohort was more likely to sustain post operative complications in the 6 months following surgery including DVT (81/13171 vs 364/80910, P<0.05), myocardial infarction (177/13171 vs 341/80910, P<0.05), acute renal failure (371/12800 vs 812/80910 P<0.05).

The 50–79year old cohort was over twice as likely to undergo revision surgery than the 80 year old cohort (HR 2.55, 95% CI 2.216–2.932, p<0.001). Of those requiring revision surgery, the elderly cohort were more likely to undergo earlier revision surgery (378days, 95%CI 236–519d vs 1586days, 95%CI 1471–1700d, p<0.001). In those undergoing revision surgery, a higher proportion were done for infection in the 80 year old cohort (39/219 (17.8%) vs 215/2809 (7.7%), p<0.05.

This study demonstrates good outcomes in terms of medical complications and a low overall risk of requiring revision surgery in patients 80years old undergoing THR. Patients over the age of 80 should be counselled on the relatively increased risk of medical complications post operatively.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 21 - 21
2 May 2024
Palit A Kiraci E Seemala V Gupta V Williams M King R
Full Access

Ideally the hip arthroplasty should not be subject to bony or prosthetic impingement, in order to minimise complications and optimise outcomes. Modern 3d planning permits pre-operative simulation of the movements of the planned hip arthroplasty to check for such impingement. For this to be meaningful, however, it is necessary to know the range of movement (ROM) that should be simulated. Arbitrary “normal” values for hip ROM are of limited value in such simulations: it is well known that hip ROM is individualised for each patient. We have therefore developed a method to determine this individualised ROM using CT scans.

CT scans were performed on 14 cadaveric hips, and the images were segmented to create 3d virtual models. Using Matlab software, each virtual hip was moved in all potential directions to the point of bony impingement, thus defining an individualised impingement-free 3d ROM envelope. This was then compared with the actual ROM as directly measured from each cadaver using a high-resolution motion capture system.

For each hip, the ROM envelope free of bony impingement could be described from the CT and represented as a 3d shape. As expected, the directly measured ROM from the cadaver study for each hip was smaller than the CT-based prediction, owing to the presence of constraining soft tissues. However, for movements associated with hip dislocation (such as flexion with internal rotation), the cadaver measurements matched the CT prediction, to within 10°.

It is possible to determine an individual's range of clinically important hip movements from a CT scan. This method could therefore be used to create truly personalised movement simulation as part of pre-operative 3d surgical planning.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 7 - 7
16 May 2024
Matthews P Scammell B Ali A Nightingale J Coughlin T Khan T Ollivere B
Full Access

Background

Ankle fractures are extremely common but unfortunately, over 20% fail to obtain good to excellent recovery. For those requiring surgical fixation, usual-care post-surgery has included six-weeks cast immobilisation and non-weightbearing. Disuse atrophy and joint stiffness are detrimental sequelae of this management. While rehabilitation, starting at two-weeks post-surgery is viewed as safe, the literature contains methodological flaws and a lack of focus on early exercise, perpetuating the controversy over the effectiveness of early exercise interventions.

Objectives

Our objectives were to determine if following operative fixation for Weber B fracture, the physiotherapy intervention, early motion and directed exercise (EMADE), applied in the clinical setting, were superior to Usual-care at 12-weeks (primary outcome) and 24-weeks.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 10 - 10
16 May 2024
McMenemy L Nguyen A Ramasamy A Walsh M Calder J
Full Access

Autologous osteochondral transplantation (AOT) is an effective treatment for large Osteochondral Lesions of the Talus (OLT), however little is reported on an athletic population, who are likely to place higher demands on the reconstruction. The aim is to report the outcomes of large OLT (>150mm2) within an athletic population. The study population was limited to professional or amateur athletes (Tegner score >6) with an OLT of size 150mm2 or greater. The surgical intervention was AOT with a donor site from the lateral femoral condyle. Clinical outcomes at a minimum of 24 months included Return to Sport, VAS and FAOS Scores. In addition, graft incorporation was evaluated by MRI using MOCART scores at 12 months post-surgery. 38 athletes including 11 professional athletes were assessed. Mean follow-up was 46 months. Mean lesion size was 249mm2. 33 patients returned to sport at their previous level and one did not return to sport (mean return to play 8.2 months). Visual analogue scores improved from 4.53 pre-operatively to 0.63 post-operatively (p=0.002). FAOS Scores improved significantly in all domains (p< 0.001). Two patients developed knee donor site pain, and both had three osteochondral plugs harvested. Univariant analysis demonstrated no association between pre-operative patient or lesion characteristics and ability to return to sport. However, there was a strong correlation between MOCART scores and ability to return to sport (AUC=0.89). Our study suggests that AOT is a viable option in the management of large osteochondral talar defects in an athletic population, with favourable return to sport levels, patient satisfaction, and FAOS/VAS scores. The ability to return to sport is predicated upon good graft incorporation and further research is required to optimise this technique. Our data also suggests that patients should be aware of the increased risk of developing knee donor site pain when three osteochondral plugs are harvested.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 14 - 14
16 May 2024
Davey M Stanton P Lambert L McCarton T Walsh J
Full Access

Aims

Management of intra-articular calcaneal fractures remains a debated topic in orthopaedics, with operative fixation often held in reserve due to concerns regarding perioperative morbidity and potential complications. The purpose of this study was to identify the characteristics of patients who developed surgical complications to inform the future stratification of patients best suited to operative treatment for intra-articular calcaneal fractures and those in whom surgery was highly likely to produce an equivocal functional outcome with potential post-operative complications.

Methods

All patients who underwent open reduction and internal fixation of calcaneal fractures utilizing the Sinus Tarsi approach between March 2014 and July 2018 were identified using theatre records. Patient imaging was used to assess pre- and post-operative fracture geometry with Computed Tomography (CT) used for pre-operative planning. Each patient's clinical presentation was established through retrospective analysis of medical records. Patients provided verbal consent to participation and patient reported outcome measures were recorded using the Maryland Foot Score.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 15 - 15
16 May 2024
Egglestone A Kakwani R Murty A Townshend D
Full Access

Introduction

When ankle arthroplasty fails the options are revision to arthrodesis or revision to arthroplasty. We report early outcomes of revision procedures for failed total replacement.

Methods

Retrospective review of prospectively collected data including post-operative complications, union, survivorship and PROMS scores to compare revision to arthrodesis and revision to arthroplasty.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 19 - 19
16 May 2024
Clifton L Kingman A Rushton P Murty A Kakwani R Coorsh J Townshend D
Full Access

Introduction

We report the functional outcome and survivorship of the Hintegra Total Ankle Replacement (TAR), in consecutive cases by multiple surgeons in a single UK institution. Between 2010–2014 the Hintegra TAR held 7.1% UK market share and surgeons should be aware of failure mechanisms.

Methods

We conducted a retrospective review of prospectively collected data for 70 consecutive Hintegra TAR cases in a single institution between 2010–2014. Data collected included patient demographics, complications, reoperations, patient reported outcome measures (PROMS: AOS, MOX-FQ, pain VAS) and patient satisfaction.


Bone & Joint 360
Vol. 11, Issue 5 | Pages 12 - 15
1 Oct 2022


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 46 - 52
1 Jan 2024
Hintermann B Peterhans U Susdorf R Horn Lang T Ruiz R Kvarda P

Aims

Implant failure has become more common as the number of primary total ankle arthroplasties (TAAs) performed has increased. Although revision arthroplasty has gained attention for functional preservation, the long-term results remain unclear. This study aimed to assess the long-term outcomes of revision TAA using a mobile-bearing prosthesis in a considerably large cohort; the risk factors for failure were also determined.

Methods

This single-centre retrospective cohort study included 116 patients (117 ankles) who underwent revision TAA for failed primary TAA between July 2000 and March 2010. Survival analysis and risk factor assessment were performed, and clinical performance and patient satisfaction were evaluated preoperatively and at last follow-up.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 943 - 945
1 Sep 2023
Haddad FS


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 1 - 2
1 Jan 2023
Haddad FS


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 837 - 838
1 Aug 2023
Kelly M McNally SA Dhesi JK


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 261 - 268
1 Mar 2023
Ruhr M Huber G Niki Y Lohner L Ondruschka B Morlock MM

Aims

The aim of the study was to investigate whether the primary stability of press-fit acetabular components can be improved by altering the impaction procedure.

Methods

Three impaction procedures were used to implant acetabular components into human cadaveric acetabula using a powered impaction device. An impaction frequency of 1 Hz until complete component seating served as reference. Overimpaction was simulated by adding ten strokes after complete component seating. High-frequency implantation was performed at 6 Hz. The lever-out moment of the acetabular components was used as measure for primary stability. Permanent bone deformation was assessed by comparison of double micro-CT (µCT) measurements before and after impaction. Acetabular component deformation and impaction forces were recorded, and the extent of bone-implant contact was determined from 3D laser scans.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1234 - 1241
1 Nov 2022
Park JH Park KT Kim SC Bukhary HA Lee SM Yoo JC

Aims

This study compared patients who underwent arthroscopic repair of large to massive rotator cuff tears (LMRCTs) with isolated incomplete repair of the tear and patients with incomplete repair with biceps tendon augmentation. We aimed to evaluate the additional benefit on clinical outcomes and the capacity to lower the re-tear rate.

Methods

We retrospectively reviewed 1,115 patients who underwent arthroscopic rotator cuff repair for full-thickness tears between October 2011 and May 2019. From this series, we identified 77 patients (28 male, 49 female) with a mean age of 64.1 years (50 to 80). Patients were classified into groups A (n = 47 incomplete) and B (n = 30 with biceps augmentation) according to the nature of their reconstruction. Clinical scores were checked preoperatively and at six months, one year, and two years postoperatively. In preoperative MRI, we measured the tear size, the degree of fatty infiltration, and muscle volume ratio of the supraspinatus. In postoperative MRI, the integrity of the repaired rotator cuff tendon was assessed using the Sugaya classification. Tendon thickness at the footprint was evaluated on T2-weighted oblique coronal view.