Advertisement for orthosearch.org.uk
Results 1 - 20 of 72
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 51 - 51
2 May 2024
Diffley T Yee T Letham C Ali M Cove R Mohammed I Kindi GA Samara A Cunningham C
Full Access

Extracapsular Hip Fractures (EHF's) are a significant health burden on healthcare services. Optimal treatment is controversial with conflicting evidence being reported. Currently treatment is undertaken with Intramedullary Nail (IMN) or Dynamic Hip Screw (DHS) constructs with a recent increase in IMN use (1). This study aims to conduct a systematic review of Randomised Control Trials published between 2020 and 2023 with particular focus on patient demographics and holistic patient outcomes. Using a unified search-protocol, RCT's published between 2020 and 2023 were collected from CENTRAL, PubMed, MEDLINE and EMBASE. Rayyan software screened duplicates. Using the CASP and Cochrane Risk of Bias Tool papers were critically examined twice, and Blood Loss, Infection and Mobility described the patient journey. Patient demographics were recorded and were contrasted with geographically diverse cohort studies to compare population differences. Parametric tests were used to determine significance levels between population demographics, namely Age and Sex. Eleven papers were included, representing 908 patients (436 Male). The mean age for patients was 64.39. There was considerable risk of bias in 7/11 studies owing to the randomization process and the recording of data. Four Cohort studies were selected for comparison representing 14314 patients. Mean age was significantly different between Cohort Studies and RCT's (Independent T-Test, df 13, t=7.8, p = <0.001, mean difference = 19.251, 95% CI = 13.888, 24.613). This was also true for sex ratios included in the studies (df 13, t = -2.268, p = 0.024, Mean Difference = -0.4884, 95% CI = -0.9702, -0.0066). To conclude, RCT's published in the post COVID-19 era are not representative of patient demographics. This has the potential to provide inaccurate information for implant selection. Additionally further research must be conducted in how to better improve RCT patient inclusion so as to be more representative of patients whilst balancing the risks of operations


Bone & Joint Open
Vol. 4, Issue 8 | Pages 602 - 611
21 Aug 2023
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims. To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture. Methods. This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty). Results. Eight female (29%) and 20 male trainees (71%), mean age 29.4 years, performed 317 DHS operations and 243 hemiarthroplasties during ten months of follow-up. Primary analysis was a random effect model with surgeon-level fixed effects of patient condition, patient age, and surgeon experience, with a random intercept for surgeon. Under the intention-to-treat principle, for hemiarthroplasty there was better implant position in favour of cadaveric training, measured by leg length discrepancy ≤ 10 mm (odds ratio (OR) 4.08 (95% confidence interval (CI) 1.17 to 14.22); p = 0.027). There were significantly fewer postoperative blood transfusions required in patients undergoing hemiarthroplasty by cadaveric-trained compared to standard-trained surgeons (OR 6.00 (95% CI 1.83 to 19.69); p = 0.003). For DHS, there was no significant between-group difference in implant position as measured by tip-apex distance ≤ 25 mm (OR 6.47 (95% CI 0.97 to 43.05); p = 0.053). No between-group differences were observed for any secondary clinical outcomes. Conclusion. Trainees randomized to additional cadaveric training performed hip fracture fixation with better implant positioning and fewer postoperative blood transfusions in hemiarthroplasty. This effect, which was previously unknown, may be a consequence of the intervention. Further study is required. Cite this article: Bone Jt Open 2023;4(8):602–611


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 19 - 19
7 Jun 2023
Ahmed M Tirimanna R Ahmed U Hussein S Syed H Malik-Tabassum K Edmondson M
Full Access

The incidence of hip fractures in the elderly is increasing. Minimally displaced and un-displaced hip fractures can be treated with either internal fixation or hemiarthroplasty. The aim was identifying the revision rate of internal fixation and hemiarthroplasty in patients 60 years or older with Garden I or II hip fractures and to identify risk factors associated with each method. A retrospective analysis was conducted from 2 Major Trauma Centres and 9 Trauma Units between 01/01/2015 and 31/12/2020. Patients managed conservatively, treated with a total hip replacement and missing data were excluded from the study. 1273 patients were included of which 26.2% (n=334) had cannulated hip fixation (CHF), 19.4% (n=247) had a dynamic hip screw (DHS) and 54.7% (n=692) had a hemiarthroplasty. 66 patients in total (5.2%) required revision surgery. The revision rates for CHF, DHS and hemiarthroplasty were 14.4%, 4%, 1.2% (p<0.001) respectively. Failed fixation was the most common reason for revision with the incidence increasing by 7-fold in the CHF group [45.8% (n=23) vs. 33.3% (n=3) in DHS; p<0.01]. The risk factors identified for CHF revision were age >80 (p<0.05), female gender (p<0.05) and smoking (p<0.05). The average length of hospital stay was decreased when using CHF compared to DHS and hemiarthroplasty (12.6 days vs 14.9 days vs 18.1 days respectively, p<0.001) and the 1 year mortality rate for CHF, DHS and hemiarthroplasty was 2.5%, 2% and 9% respectively. Fixation methods for Garden I and II hip fractures in elderly patients are associated with a higher revision rate than hemiarthroplasty. CHF has the highest revision rate at 14.4% followed by DHS and hemiarthroplasty. Female patients, patients over the age of 80 and patients with poor bone quality are considered high risk for fixation failure with CHF. When considering a fixation method in such patients, DHS is more robust than a screw construct, followed by hemiarthroplasty


Bone & Joint Open
Vol. 4, Issue 5 | Pages 329 - 337
8 May 2023
Khan AQ Chowdhry M Sherwani MKA McPherson EJ

Aims

Total hip arthroplasty (THA) is considered the preferred treatment for displaced proximal femoral neck fractures. However, in many countries this option is economically unviable. To improve outcomes in financially disadvantaged populations, we studied the technique of concomitant valgus hip osteotomy and operative fixation (VOOF). This prospective serial study compares two treatment groups: VOOF versus operative fixation alone with cannulated compression screws (CCSs).

Methods

In the first series, 98 hip fixation procedures were performed using CCS. After fluoroscopic reduction of the fracture, three CCSs were placed. In the second series, 105 VOOF procedures were performed using a closing wedge intertrochanteric osteotomy with a compression lag screw and lateral femoral plate. The alignment goal was to create a modified Pauwel’s fracture angle of 30°. After fluoroscopic reduction of fracture, lag screw was placed to achieve the calculated correction angle, followed by inter-trochanteric osteotomy and placement of barrel plate. Patients were followed for a minimum of two years.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 89 - 89
17 Apr 2023
Alzahrani S Aljuaid M Bazaid Z Shurbaji S
Full Access

A Morel-Lavallee lesion (MLL) is a benign cystic lesion that occurs due to injury to the soft-tissue envelope's perforating vascular and lymphatic systems, resulting in a distinctive hemolymphatic fluid accumulation between the tissue layers. The MLL has the potential to make a significant impact on the treatment of orthopaedic injuries.

A 79-year-old male patient community ambulatory with assisting aid (cane) known case of Diabetes mellitus, hypertension, bronchial asthma and ischemic heart disease. He was brought to the Emergency, complaining of right hip discomfort and burning sensation for the last 5 days with no history of recent trauma at all. Patient had history of right trochanteric femur fracture 3 years ago, treated with DHS in a privet service. Clinical and Radiological assessment showed that the patient mostly has acute MLL due to lag screw cut out. We offered the patient the surgical intervention, but he refused despite explaining the risks of complications if not treated and preferred to receive the conservative treatment. Compression therapy management explained to him including biker's shorts (instructed to be worn full-time a day) and regular follow up in clinic. Symptom's improvement was reported by the patient in the subsequent visits.

In the polytrauma patient, a delayed diagnosis of these lesions is conceivable due to the presence of more visible injuries. It's located over the greater trochanter more commonly, but sometimes in other areas such as the lower lumbar region, the thigh, or the calf. Incorrect or delayed diagnosis and care can have unfavorable outcomes such as infection, pseudocyst development, and cosmetologically deformity. Magnetic resonance imaging (MRI) and ultrasound will aid in MLL diagnosis. However, the effectiveness of MLL therapy remains debatable.

We strongly believe that the MLL caused due to tangential shear forces applied to the soft tissue leads to accumulation of the blood and/or lymph between the subcutaneous and overlying fascia and it often misdiagnosed due to other distracting injuries. Nontheless, in our case we reported MLL occur due to internal pressure on the fascia caused by cut out of DHS lag screw.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 92 - 92
17 Apr 2023
Raina D Mrkonjic F Tägil M Lidgren L
Full Access

A number of techniques have been developed to improve the immediate mechanical anchorage of implants for enhancing implant longevity. This issue becomes even more relevant in patients with osteoporosis who have fragile bone. We have previously shown that a dynamic hip screw (DHS) can be augmented with a calcium sulphate/hydroxyapatite (CaS/HA) based injectable biomaterial to increase the immediate mechanical anchorage of the DHS system to saw bones with a 400% increase in peak extraction force compared to un-augmented DHS. The results were also at par with bone cement (PMMA). The aim of this study was to investigate the effect of CaS/HA augmentation on the integration of a different fracture fixation device (gamma nail lag-screw) with osteoporotic saw bones. Osteoporotic saw bones (bone volume fraction = 15%) were instrumented with a gamma nail without augmentation (n=8) or augmented (n=8) with a CaS/HA biomaterial (Cerament BVF, Bonesupport AB, Sweden) using a newly developed augmentation method described earlier. The lag-screws from both groups were then pulled out at a displacement rate of 0.5 mm/s until failure. Peak extraction force was recorded for each specimen along with photographs of the screws post-extraction. A non-parametric t-test was used to compare the two groups. CaS/HA augmentation of the lag-screw led to a 650% increase in the peak extraction force compared with the controls (p<0.01). Photographs of the augmented samples shows failure of the saw-bones further away from the implant-bone interface indicating a protective effect of the CaS/HA material. We present a novel method to enhance the immediate mechanical anchorage of a lag-screw to osteoporotic bone and it is also envisaged that CaS/HA augmentation combined with systemic bisphosphonate treatment can lead to new bone formation and aid in the reduction of implant failures and re-operations


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 13 - 13
3 Mar 2023
Rohra S Sinha A Kemp M Rethnam U
Full Access

Background. Dynamic Hip Screw (DHS) is the most frequently used implant in management of intertrochanteric femoral fractures. There is a known statistical relationship between a tip-apex distance (TAD) >25mm and higher rate of implant failure. Our aim was to analyse all DHS procedures performed in our trust from seventeen months and compare their TAD values to the acceptable standard of ≤25mm. Methods. All patients undergoing DHS between April 2020-August 2021 were identified from our theatre system. Additionally, those presenting to hospital with implant failures were included. Patient demographics, date of surgery, fracture classification (AO) and date/mode of failure were recorded. Intraoperative fluoroscopy images were reviewed to calculate TAD, screw location and neck shaft angles by two independent observers. Results. 215 patients were identified, five of which were excluded due to inadequate fluoroscopy. Failure was seen in 3.3% of the cohort (n=7), of which 71.4% had an unacceptable TAD. In total, 21 patients (10%) had TAD >25mm, of whom 12 had superiorly and 15 had posteriorly placed screws. There were no failures in patients with a TAD of <20mm whereas a TAD >30mm had 50% failure rate. Conclusion. This audit reinforces the importance of aiming for a low TAD (preferably <20mm) intraoperatively. It is also desirable to avoid superiorly and significantly posteriorly placed screws. Implications. Complex hip revision surgery in the elderly bears substantial financial implications to the NHS and, more importantly, causes prolonged morbidity to the patient. Adhering to established standards will ensure reduced implant failure and best patient care


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 5 - 5
10 Feb 2023
Badurudeen A Mathai N Altaf D Mohamed W Deglurkar M
Full Access

The aim of this study is to analyse the radiological outcomes and predictors of avascular necrosis following 2-hole DHS in Garden I and II neck of femur fractures in patients more than 60 years with a minimum follow up of one year.

We retrospectively reviewed 51 consecutive patients aged more than 60 years who underwent DHS fixation for Garden I and II fractures. Demographics, fracture classification, time to surgery, pre-operative AMTS, preoperative posterior tilt angle, quality of reduction, pre and post-operative haemoglobin(hb), creatinine and comorbidities were analysed for correlation with AVN using Chi-Square test, Independent Sample and paired t test.

There were 40 (78.4%) females and the mean age of the cohort was 77 years. 28 and 23 were Garden I and II NOF fractures respectively. Union was observed in all our patients except one(kappa =1). 12/51(23.5%) developed AVN of the femoral head. Statistically significant higher incidence of AVN was noted in patients with a pre-op tilt angle > 200 (p = 0.006). The mean drop in Hb was higher in patients who developed AVN (21.5 g/L) versus the non-AVN group (15.9 g/L) (p = 0.001). There was no difference in AVN rates with respect to laterality, mean time to surgery, pre-op AMTS and Charlson comorbidity index. 4/52 (7.6%) had re-operations (one hardware prominence, two conversions to arthroplasty, one fixation failure during the immediate post-op period). The 30-day and one year mortality rates were 1.9 % and 11.7 % respectively.

2-hole DHS fixation in undisplaced NOF fractures has excellent union rates. A pre-operative posterior tilt angle of >200 and a greater difference in pre and post operative haemoglobin were found to correlate positively with the progression to AVN . No correlation was observed between AVN and time to surgery, laterality, quality of reduction and comorbidities.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 13 - 13
1 Nov 2022
Badurdeen A Mathai N Altaf D Mohamed W Deglurkar M
Full Access

Abstract

Background

The aim of this study is to analyse the radiological outcomes and predictors of avascular necrosis following 2-hole DHS in Garden I and II neck of femur fractures in patients >60 years with a minimum follow up of one year.

Methods

We retrospectively reviewed 51 consecutive patients >60 years who underwent DHS fixation for Garden I and II fractures. Demographics, fracture classification, time to surgery, pre-operative AMTS, preoperative posterior tilt angle, quality of reduction, pre and post-operative haemoglobin (hb), creatinine and comorbidities were analysed.


Bone & Joint 360
Vol. 11, Issue 5 | Pages 34 - 36
1 Oct 2022


Bone & Joint Research
Vol. 11, Issue 2 | Pages 102 - 111
1 Feb 2022
Jung C Cha Y Yoon HS Park CH Yoo J Kim J Jeon Y

Aims

In this study, we aimed to explore surgical variations in the Femoral Neck System (FNS) used for stable fixation of Pauwels type III femoral neck fractures.

Methods

Finite element models were established with surgical variations in the distance between the implant tip and subchondral bone, the gap between the plate and lateral femoral cortex, and inferior implant positioning. The models were subjected to physiological load.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 782 - 787
3 Apr 2021
Mahmood A Rashid F Limb R Cash T Nagy MT Zreik N Reddy G Jaly I As-Sultany M Chan YTC Wilson G Harrison WJ

Aims

Despite the COVID-19 pandemic, incidence of hip fracture has not changed. Evidence has shown increased mortality rates associated with COVID-19 infection. However, little is known about the outcomes of COVID-19 negative patients in a pandemic environment. In addition, the impact of vitamin D levels on mortality in COVID-19 hip fracture patients has yet to be determined.

Methods

This multicentre observational study included 1,633 patients who sustained a hip fracture across nine hospital trusts in North West England. Data were collected for three months from March 2020 and for the same period in 2019. Patients were matched by Nottingham Hip Fracture Score (NHFS), hospital, and fracture type. We looked at the mortality outcomes of COVID-19 positive and COVID-19 negative patients sustaining a hip fracture. We also looked to see if vitamin D levels had an impact on mortality.


Bone & Joint Open
Vol. 1, Issue 10 | Pages 645 - 652
19 Oct 2020
Sheridan GA Hughes AJ Quinlan JF Sheehan E O'Byrne JM

Aims

We aim to objectively assess the impact of COVID-19 on mean total operative cases for all indicative procedures (as outlined by the Joint Committee on Surgical Training (JCST)) experienced by orthopaedic trainees in the deanery of the Republic of Ireland. Subjective experiences were reported for each trainee using questionnaires.

Methods

During the first four weeks of the nationwide lockdown due to COVID-19, the objective impact of the pandemic on each trainee’s surgical caseload exposure was assessed using data from individual trainee logbook profiles in the deanery of the Republic of Ireland. Independent predictor variables included the trainee grade (ST 3 to 8), the individual trainee, the unit that the logbook was reported from, and the year in which the logbook was recorded. We used the analysis of variance (ANOVA) test to assess for any statistically significant predictor variables. The subjective experience of each trainee was captured using an electronic questionnaire.


Bone & Joint Open
Vol. 1, Issue 9 | Pages 594 - 604
24 Sep 2020
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims. To develop a core outcome set of measurements from postoperative radiographs that can be used to assess technical skill in performing dynamic hip screw (DHS) and hemiarthroplasty, and to validate these against Van der Vleuten’s criteria for effective assessment. Methods. A Delphi exercise was undertaken at a regional major trauma centre to identify candidate measurement items. The feasibility of taking these measurements was tested by two of the authors (HKJ, GTRP). Validity and reliability were examined using the radiographs of operations performed by orthopaedic resident participants (n = 28) of a multicentre randomized controlled educational trial (ISRCTN20431944). Trainees were divided into novice and intermediate groups, defined as having performed < ten or ≥ ten cases each for DHS and hemiarthroplasty at baseline. The procedure-based assessment (PBA) global rating score was assumed as the gold standard assessment for the purposes of concurrent validity. Intra- and inter-rater reliability testing were performed on a random subset of 25 cases. Results. In total, 327 DHS and 248 hemiarthroplasty procedures were performed by 28 postgraduate year (PGY) 3 to 5 orthopaedic trainees during the 2014 to 2015 surgical training year at nine NHS hospitals in the West Midlands, UK. Overall, 109 PBAs were completed for DHS and 80 for hemiarthroplasty. Expert consensus identified four ‘final product analysis’ (FPA) radiological parameters of technical success for DHS: tip-apex distance (TAD); lag screw position in the femoral head; flushness of the plate against the lateral femoral cortex; and eight-cortex hold of the plate screws. Three parameters were identified for hemiarthroplasty: leg length discrepancy; femoral stem alignment; and femoral offset. Face validity, content validity, and feasibility were excellent. For all measurements, performance was better in the intermediate compared with the novice group, and this was statistically significant for TAD (p < 0.001) and femoral stem alignment (p = 0.023). Concurrent validity was poor when measured against global PBA score. This may be explained by the fact that they are measuring difference facets of competence. Intra-and inter-rater reliability were excellent for TAD, moderate for lag screw position (DHS), and moderate for leg length discrepancy (hemiarthroplasty). Use of a large multicentre dataset suggests good generalizability of the results to other settings. Assessment using FPA was time- and cost-effective compared with PBA. Conclusion. Final product analysis using post-implantation radiographs to measure technical skill in hip fracture surgery is feasible, valid, reliable, and cost-effective. It can complement traditional workplace-based assessment for measuring performance in the real-world operating room . It may have particular utility in competency-based training frameworks and for assessing skill transfer from the simulated to live operating theatre. Cite this article: Bone Joint Open 2020;1-9:594–604


Bone & Joint Open
Vol. 1, Issue 8 | Pages 500 - 507
18 Aug 2020
Cheruvu MS Bhachu DS Mulrain J Resool S Cool P Ford DJ Singh RA

Aims

Our rural orthopaedic service has undergone service restructure during the COVID-19 pandemic in order to sustain hip fracture care. All adult trauma care has been centralised to the Royal Shrewsbury Hospital for assessment and medical input, before transferring those requiring operative intervention to the Robert Jones and Agnes Hunt Orthopaedic Hospital. We aim to review the impact of COVID-19 on hip fracture workload and service changes upon management of hip fractures.

Methods

We reviewed our prospectively maintained trust database and National Hip Fracture Database records for the months of March and April between the years 2016 and 2020. Our assessment included fracture pattern (intrascapular vs extracapsular hip fracture), treatment intervention, length of stay and mortality.


Bone & Joint 360
Vol. 9, Issue 2 | Pages 33 - 37
1 Apr 2020


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 91 - 96
1 Jun 2019
Smith A Denehy K Ong KL Lau E Hagan D Malkani A

Aims

Cephalomedullary nails (CMNs) are commonly used for the treatment of intertrochanteric hip fractures. Total hip arthroplasty (THA) may be used as a salvage procedure when fixation fails in these patients. The aim of this study was to analyze the complications of THA following failed intertrochanteric hip fracture fixation using a CMN.

Patients and Methods

Patients who underwent THA were identified from the 5% subset of Medicare Parts A/B between 2002 and 2015. A subgroup involving those with an intertrochanteric fracture that was treated using a CMN during the previous five years was identified and compared with the remaining patients who underwent THA. The length of stay (LOS) was compared using both univariate and multivariate analysis. The incidence of infection, dislocation, revision, and re-admission was compared between the two groups, using multivariate analysis adjusted for demographic, hospital, and clinical factors.


Bone & Joint Research
Vol. 8, Issue 2 | Pages 49 - 54
1 Feb 2019
Stravinskas M Nilsson M Vitkauskiene A Tarasevicius S Lidgren L

Objectives

The aim of this study was to analyze drain fluid, blood, and urine simultaneously to follow the long-term release of vancomycin from a biphasic ceramic carrier in major hip surgery. Our hypothesis was that there would be high local vancomycin concentrations during the first week with safe low systemic trough levels and a complete antibiotic release during the first month.

Methods

Nine patients (six female, three male; mean age 75.3 years (sd 12.3; 44 to 84)) with trochanteric hip fractures had internal fixations. An injectable ceramic bone substitute, with hydroxyapatite in a calcium sulphate matrix, containing 66 mg of vancomycin per millilitre, was inserted to augment the fixation. The vancomycin elution was followed by simultaneously collecting drain fluid, blood, and urine.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 80 - 80
1 Apr 2018
Sugand K van Duren B Wescott R Carrington R Hart A
Full Access

Background. Hip fractures cause significant morbidity and mortality, affecting 70,000 people in the UK each year. The dynamic hip screw (DHS) is used for the osteosynthesis of extracapsular neck of femur fractures, a procedure that requires complex psychomotor skills to achieve optimal lag screw positioning. The tip-apex distance (TAD) is a measure of the position of the lag screw from the apex of the femoral head, and is the most comprehensive predictor of cut-out (failure of the DHS construct). To develop these skills, trainees need exposure to the procedure, however with the European Working Time Directive, this is becoming harder to achieve. Simulation can be used as an adjunct to theatre learning, however it is limited. FluoroSim is a digital fluoroscopy simulator that can be used in conjunction with workshop bones to simulate the first step of the DHS procedure (guide-wire insertion) using image guidance. This study assessed the construct validity of FluoroSim. The null hypothesis stated that there would be no difference in the objective metrics recorded from FluoroSim between users with different exposure to the DHS procedure. Methods. This multicentre study recruited twenty-six orthopaedic doctors. They were categorised into three groups based on the number of DHS procedures they had completed as the primary surgeon (novice <10, intermediate 10≤x<40 and experienced ≥40). Twenty-six participants completed a single DHS guide-wire attempt into a workshop bone using FluoroSim. The TAD, procedural time, number of radiographs, number of guide-wire retires and cut-out rate (COR) were recorded for each attempt. Results. A significant construct effect was seen for TAD and COR between novice and other users (p < 0.05). The intermediate and experienced users were not significantly different for these metrics. For all other metrics, experienced users had the highest score, contrary to expectation. Conclusion. FluoroSim was able to separate novice users from other cohorts for the two clinically significant outcome metrics. We can therefore partially reject the null hypothesis as construct validity was present for TAD and COR. We have demonstrated that FluoroSim has the potential to be a useful adjunct when learning the psychomotor skills needed for the DHS procedure away from theatre


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 81 - 81
1 Apr 2018
Sugand K Wescott R van Duren B Carrington R Hart A
Full Access

Background. Training within surgery is changing from the traditional Halstedian apprenticeship model. There is need for objective assessment of trainees, especially their technical skills, to ensure they are safe to practice and to highlight areas for development. In addition, due to working time restrictions in both the UK and the US, theatre time is being limited for trainees, reducing their opportunities to learn such technical skills. Simulation is one adjunct to training that can be utilised to both assess trainees objectively, and provide a platform for trainees to develop their skills in a safe and controlled environment. The insertion of a dynamic hip screw (DHS) relies on complex psychomotor skills to obtain an optimal implant position. The tip-apex distance (TAD) is a measurement of this positioning, used to predict failure of the implant. These skills can be obtained away from theatre using workshop bone simulation, however this method does not utilise fluoroscopy due to the associated radiation risks. FluoroSim is a novel digital fluoroscopy simulator that can recreate digital radiographs with workshop bone simulation for the insertion of a DHS guide-wire. In this study, we present the training effect demonstrated on FluoroSim. The null hypothesis states that no difference will be present between users with different amounts of exposure to FluoroSim. Methods. Medical students were recruited from three London universities and randomised into a training (n=23) and a control (n=22) cohort. All participants watched a video explanation of the simulator and task and were blinded to their allocation. Training participants completed 10 attempts in total, 5 attempts in week one, followed by a one week wash out period, followed by 5 attempts in week 2. The control group completed a single attempt each week. For each attempt, 5 metrics were recorded; TAD, procedural time, number of radiographs, number of guide-wire retires and cut-out rate (COR). Results. No significant difference was present for any metric between the groups at baseline; randomisation had produced heterogeneous groups minimising selection bias. Intragroup training effect (comparison of initial and last attempt) was significant for all metrics in the training group (p < 0.05) but for no metrics in the control group. The intergroup training effect (comparison of training group attempt ten to control group attempt ten) was present for procedural time, number of radiographs and number of guide-wire retries (p < 0.05). Significance was not reached for TAD and COR. Conclusion. FluoroSim shows skill acquisition with repeat exposure, so the null hypothesis can be rejected. This study has demonstrated the merits of FluoroSim as a training adjunct for psychomotor skill development in a DHS setting