Advertisement for orthosearch.org.uk
Results 1 - 20 of over 10000
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 79 - 79
22 Nov 2024
Luger M Böhler C Staats K Windhager R Sigmund IK
Full Access

Aim. Diagnosing low-grade periprosthetic joint infections (PJI) can be very challenging due to low-virulent microorganisms capable of forming biofilm. Clinical signs can be subtle and may be similar to those of aseptic failure. To minimize morbidity and mortality and to preserve quality of life, accurate diagnosis is essential. The aim of this study was to assess the performance of various diagnostic tests in diagnosing low-grade PJI. Methods. Patients undergoing revision surgery after total hip and knee arthroplasty were included in this retrospective cohort study. A standardized diagnostic workup was performed using the components of the 2021 European Bone and Joint Infection Society (EBJIS) definition of PJI. For statistical analyses, the respective test was excluded from the infection definition to eliminate incorporation bias. Receiver-operating-characteristic curves were used to calculate the diagnostic performance of each test, and their area-under-the-curves (AUC) were compared using the z-test. Results. 422 patients undergoing revision surgery after total hip and knee arthroplasty were included in this study. 208 cases (49.3%) were diagnosed as septic. Of those, 60 infections (28.8%) were defined as low-grade PJI (symptoms >4 weeks and caused by low-virulent microorganisms (e. g. coagulase-negative staphylococci, Cutibacterium spp., enterococci and Actinomyces)). Performances of the different test methods are listed in Table 1. Synovial fluid (SF) - WBC (white blood cell count) >3000G/L (0.902), SF - %PMN (percentage of polymorphonuclear neutrophils) > 65% (0.959), histology (0.948), and frozen section (0.925) showed the best AUCs. Conclusion. The confirmatory criteria according to the EBJIS definition showed almost ideal performances in ruling-in PJI (>99% specificity). Histology and synovial fluid cell count (SF-WBC and SF-%PMN) showed excellent accuracies for diagnosing low-grade PJI. However, a reduced immune reaction in these cases may necessitate lower cut-off values. Intraoperative frozen section may be valuable in cases with inconclusive preoperative diagnosis. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 65 - 65
22 Nov 2024
Alonso MG González AG Suárez VV Lázaro JS
Full Access

Aim. Irrigation and debridement with an irrigation solution are essential components of the surgical management of acute and chronic periprosthetic joint infection (PJI). Nevertheless, there is a lack of agreement regarding the most effective solution to use. The aim of the study was to perform a systematic review and meta-analysis of the current literature concerning the efficacy of different irrigation solutions over bacterial biofilm. Method. This study was conducted in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analysis extension for Network meta-analysis (PRISMA-NMA) checklist for systematic reviews and meta-analyses. A comprehensive literature search of PubMed, Cochrane Library, Web of Science and Scopus databases from inception to September 1, 2023. We combined terms related to PJI, biofilm and irrigation solutions studied in vitro. We performed a network meta-analysis to analyze which irrigation solution achieved a higher reduction of colony forming units (CFU) after specific exposure times, always with a maximum of five minutes, replicating intraoperative conditions. Effect-size was summarized with logarithmic response ratio (logRR) and 95% confidence intervals (95% CI). The rank probability for each treatment was calculated using the p-scores. Results. We screened 233 potential sources. Following deduplication, screening and full-text review, four studies with ten irrigation solutions for different duration of exposures were included, always less than five minutes, replicating intraoperative conditions. Solutions were studied over mature biofilms of most frequent bacteria grown over metal, bone cement or polyethylene surfaces. The highest effect was achieved with povidone iodine 10% during 5 minutes (logRR: −12.02; 95% CI: −14.04, −9.99). The best ranked solutions were povidone iodine 10% during five, three and one minute (respective p-scores: 0.977, 0.932, 0.887) and its combination with hydrogen peroxide for 3 minutes (p-score: 0.836). Povidone iodine 0.3% acting for 5 minutes completed the top 5 best ranked solutions in this study (p-score: 0.761). We assumed that there were no inconsistencies in our network because after examining both scenarios, with and without inconsistencies, the results were not significantly different. Conclusions. Our results show that 10% povidone-iodine is the best antiseptic solution when studied in vitro in the context of prosthetic joint infection. However, the included studies did not evaluate the possible cytotoxic effects of these solutions. This should also be taken into account before choosing the most appropriate antiseptic solution


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 110 - 110
14 Nov 2024
Vettese J Julie M Evrard R Fieve L Lengelé B Cornu O
Full Access

Introduction. In tissue engineering, the establishment of sufficient vascularization is essential for tissue viability and functionality. Inadequate vascularization disrupts nutrients and oxygen supply. Nonetheless, regenerating intricate vascular networks represents a significant challenge. Consequently, research efforts devoted to preserving and regenerating functional vascular networks in engineered tissues are of paramount importance. The present work aims to validate a decellularisation process with preservation of the vascular network and extracellular matrix (ECM) components in fasciocutaneous flaps. Method. Five vascularized fasciocutaneous flaps from cadaveric donors were carefully harvested from the anterolateral thigh (ALT), preserving the main perforator of the fascia lata. The entire ALT flap underwent decellularization by perfusion using a clinically validated chemical protocol. Fluoroscopy and computed tomography (CT) were used to analyze the persistence of the vascular network within the flap, pre- and post-decellularization. Histological analysis, including hematoxylin and eosin staining, and quantitative DNA assessment evaluated decellularization efficacy. Further qualitative (immunohistochemistry, IHC) and quantitative analyses were conducted to assess the preservation of ECM components, such as collagen, glycosaminoglycans, and elastin. Result. On average, the ALT flap maintains 82% of the perfusion area (p = 0.094) post-treatment. Histological analysis confirmed decellularization efficacy and revealed structural rearrangement. Paired analysis revealed a significant decrease in DNA levels (<14.8 ng/mg of dry weight, p****< 0.0001) and well-maintained ECM. IHC indicated the persistence of elastine, collagen IV and laminin. Quantitative analysis confirmed elastin (p = 0.44) and collagen persistence (+74%, p*** = 0.001, albeit with a decrease in matrix glycosaminoglycans (-41%, p*** = 0.01). Conclusion. Decellularization effectively removed cells, while preserving the ECM overall and maintaining some vascular network integrity. Yet, further study is needed to validate these findings, involving microCT examination of the vascular network and its ability to support cell colonization and viability


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 24 - 24
14 Nov 2024
Petersen ET Linde KN Burvil CCH Rytter S Koppens D Dalsgaard J Hansen TB Stilling M
Full Access

Introduction. Knee osteoarthritis often causes malalignment and altering bone load. This malalignment is corrected during total knee arthroplasty surgery, balancing the ligaments. Nonetheless, preoperative gait patterns may influence postoperative prosthesis load and bone support. Thus, the purpose is to investigate the impact of preoperative gait patterns on postoperative femoral and tibial component migration in total knee arthroplasty. Method. In a prospective cohort study, 66 patients with primary knee osteoarthritis undergoing cemented Persona total knee arthroplasty were assessed. Preoperative knee kinematics was analyzed through dynamic radiostereometry and motion capture, categorizing patients into four homogeneous gait patterns. The four subgroups were labeled as the flexion group (n=20), the abduction (valgus) group (n=17), the anterior drawer group (n=10), and the tibial external rotation group (n=19). The femoral and tibial component migration was measured using static radiostereometry taken supine on the postoperative day (baseline) and 3-, 12-, and 24- months after surgery. Migration was evaluated as maximum total point motion. Result. Of the preoperatively defined four subgroups, the abduction group with a valgus-characterized gait pattern exhibited the highest migration for both the femoral (1.64 mm (CI95% 1.25; 2.03)) and tibial (1.21 mm (CI95% 0.89; 1.53)) components at 24-month follow-up. For the femoral components, the abduction group migrated 0.6 mm (CI95% 0.08; 1.12) more than the external rotation group at 24 months. For the tibial components, the abduction group migrated 0.43 mm (CI95% 0.16; 0.70) more than the external rotation group at 3 months. Furthermore, at 12- and 24-months follow-up the abduction group migrated 0.39 mm (95%CI 0.04; 0.73) and 0.45 mm (95%CI 0.01; 0.89) more than the flexion group, respectively. Conclusion. A preoperative valgus-characterized gait pattern seems to increase femoral and tibial component migration until 2 years of follow-up. This suggests that the implant fixation depends on load distributions originating from specific preoperative gait patterns


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 88 - 88
14 Nov 2024
Gögele CL Fleischmann N Hofman S Frank E Werner C Kokozidou M Tanzil GS
Full Access

Introduction. Diabetes mellitus type 2 (DMT2) patients often develop Achilles tendon (AS) degeneration. The ZDF rat model is often used to study DMT2. Hence, this study investigated whether tenocytes isolated from diabetic and non diabetic ZDF rats respond differentially to normo- (NG) and hyperglycemic (HG) conditions in the presence of tumor necrosis (TNF)α. Method. AS tenocytes isolated from adult diabetic (fa/fa) or lean (fa/+) Zucker Diabetic Fatty (ZDF) rats were treated with 10 ng/mL TNFα either under NG or HG conditions (1 g/L versus 4.5 g/L glucose). Tendons were characterized histopathologically using Movin score. Tenocyte survival, metabolic activity, gene and/or protein expression of the main tendon extracellular matrix (ECM) component collagen type 1, the myofibroblast marker alpha smooth muscle actin (αSMA, Acta2), complement regulatory factors, the antioxidant defense enzyme heme oxygenase-1 (Hmox1), suppressors of cytokine signaling (Socs)1 and Soc3 were analyzed. Result. Tendons of diabetic rats showed significantly higher Movin score values suggesting tendon degeneration. Tenocyte vitality remained high, but metabolic activity was impaired by HG conditions, irrespectively of tenocyte origin. Higher amounts of αSMA were visualized in tendons/cells of diabetic rats or those exposed to TNFα. Collagen type 1 protein and gene expression was suppressed by TNFα (NG), but only in cells of non diabetic animals. The anaphylatoxin receptor C3aR was higher expressed in tenocytes from diabetic animals. CD46 was suppressed by TNFα (NG) in cells of diabetic rats. Hmox1, Socs1 and Socs3 were induced by HG, but only in tenocytes of diabetic rats (4 h). Conclusion. The response of tenocytes to TNFα depends on glucose supply and cell origin suggesting their irreversible impairment in DMT2


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 85 - 85
14 Nov 2024
Florit MG Graça AL Domingues RMA Gomes MME
Full Access

Introduction. Healthy tendons are mainly composed of aligned collagen hierarchically organized from collagen fibrils to fiber bundles with a scarce cellular population mainly composed of tenocytes and tendon stem/progenitor cells. However, injured tendon acquires a fibrotic state characterized by a loss of ECM alignment and increased cellularization. The lack of reliable 3D models that recreate the organization and microenvironment of healthy and diseased tendons is one of the main obstacles faced by the scientific community. Method. To recreate the architecture of healthy and diseased tendons, electrospun nanofiber scaffolds with anisotropic and isotropic nanotopography were developed. These scaffolds were coated with a shell consisting of cell-laden hydrogels encapsulating human adipose-derived stem cells (hASCs) to include the living component. To show the versatility of the system, extracellular vesicles (EVs) were encapsulated in the hydrogel as biological cues. The living fibers were characterized by microscopy and morphological analysis. The morphology and phenotype of cells was evaluated using microscopy, gene expression analysis and immunostainings for tendon markers. Results. Scaffolds mimicked the native hierarchical structure of tendons and size of tendon fascicles. hASCs showed high elongation and cytoskeleton anisotropic organization, typical of tenocytes. Moreover, the bioengineered living fibers supported the tenogenic differentiation of stem cells over time, as indicated by the sustained expression of tenogenic and extracellular matrix markers. Finally, the hydrogel layer acted not only as a hydrated biomimetic environment adequate for cell encapsulation but also as a carrier and delivery system of EVs to cells, which improved their tenogenic commitment. Conclusion. We bioengineered composite living fibers made of hierarchically organized electrospun fibers, coated with hydrogel encapsulating hASCs and biofunctional EVs. These provide an in vitro system to recreate tendon, allowing for the study of the effects of biophysical cues in tendon microenvironments and the influence of biologics on cells behavior. Acknowledgments. CP21/00136, PI22/01686, CA22170, 10.54499/2020.03410.CEECIND/CP1600/CT0013, 10.54499/2022.05526.PTDC


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 122 - 122
14 Nov 2024
Tilotta V Vadalà G Giacomo GD Colaiacomo C Cicione C Ambrosio L Russo F Denaro V Papalia R
Full Access

Introduction. Osteoarthritis (OA) is a predominant chronic degenerative disease exerting a deep impact on quality of life and healthcare systems. Recent evidences suggest that pyroptosis, a programmed cell death characterized by inflammatory cytokine release, may play a significant role in modulating OA pain. The aim of the study is to investigate the potential role of extracellular vesicles derived from umbilical cord Wharton's jelly (WJ-MSC EVs) in the attenuation of the pyroptotic process on human chondrocytes (hOAC) pre-treated with synovial fluid in a 3D in vitro model. Method. EVs isolated by tangential filtration of the conditioned medium of WJ-MSCs were characterized for: morphology by TEM, surface markers by WB and size by NTA. Confocal microscopy was used to identify PKH26-labelled EVs and monitor their incorporation into hOACs. The hOACs from surgical waste material of patients undergoing knee replacement, expanded, encapsulated in alginate beads were pre-treated with synovial fluid for 24 h (SF) and subsequently co-incubated with WJ-MSC EVs. We examined viability (CCK-8), metabolic activity (MTT), nitrite production (Griess) activation of the pyroptotis (IF), DNA quantification (PicoGreen) and gene expression levels of extracellular matrix (ECM) components (qPCR). One-way ANOVA analysis was used to compare the groups under exam and data were expressed as mean ± S.D. Result. WJ-MSC EVs increased hOACs viability and metabolic activity. The production of nitrites is significantly decreased compared sample group treated with SF. WJ-MSC EVs inhibited inflammasomes NLRP3 (nucleotide-binding domain, leucine-rich repeat pyrin domain containing 3) activation. The ECM catabolic genes decreased compared to the inflamed SF group for ADAMTS-5 and MMP-1. Conclusion. Our results supported the potential use of WJ-MSC EVs as a cell-free strategy for OA, overcoming the side effects of cell-therapy. Moreover, WJ-MSC EVs are able to mitigate SF-treated hOACs pyroptotic death, attenuate ECM degradation and oxidative stress counteracting the inflamed status in OA development and progression


Aims

For rare cases when a tumour infiltrates into the hip joint, extra-articular resection is required to obtain a safe margin. Endoprosthetic reconstruction following tumour resection can effectively ensure local control and improve postoperative function. However, maximizing bone preservation without compromising surgical margin remains a challenge for surgeons due to the complexity of the procedure. The purpose of the current study was to report clinical outcomes of patients who underwent extra-articular resection of the hip joint using a custom-made osteotomy guide and 3D-printed endoprosthesis.

Methods

We reviewed 15 patients over a five-year period (January 2017 to December 2022) who had undergone extra-articular resection of the hip joint due to malignant tumour using a custom-made osteotomy guide and 3D-printed endoprosthesis. Each of the 15 patients had a single lesion, with six originating from the acetabulum side and nine from the proximal femur. All patients had their posterior column preserved according to the surgical plan.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 1013 - 1019
11 Nov 2024
Clark SC Pan X Saris DBF Taunton MJ Krych AJ Hevesi M

Aims. Distal femoral osteotomies (DFOs) are commonly used for the correction of valgus deformities and lateral compartment osteoarthritis. However, the impact of a DFO on subsequent total knee arthroplasty (TKA) function remains a subject of debate. Therefore, the purpose of this study was to determine the effect of a unilateral DFO on subsequent TKA function in patients with bilateral TKAs, using the contralateral knee as a self-matched control group. Methods. The inclusion criteria consisted of patients who underwent simultaneous or staged bilateral TKA after prior unilateral DFO between 1972 and 2023. The type of osteotomy performed, osteotomy hardware fixation, implanted TKA components, and revision rates were recorded. Postoperative outcomes including the Forgotten Joint Score-12 (FJS-12), Tegner Activity Scale score, and subjective knee preference were also obtained at final follow-up. Results. A total of 21 patients underwent bilateral TKA following unilateral DFO and were followed for a mean of 31.5 years (SD 11.1; 20.2 to 74.2) after DFO. The mean time from DFO to TKA conversion was 13.1 years (SD 9.7) with 13 (61.9%) of DFO knees converting to TKA more than ten years after DFO. There was no difference in arthroplasty implant systems employed in both the DFO-TKA and TKA-only knees (p > 0.999). At final follow-up, the mean FJS-12 of the DFO-TKA knee was 62.7 (SD 36.6), while for the TKA-only knee it was 65.6 (SD 34.7) (p = 0.328). In all, 80% of patients had no subjective knee preference or preferred their DFO-TKA knee. Three DFO-TKA knees and two TKA-only knees underwent subsequent revision following index arthroplasty at a mean of 12.8 years (SD 6.9) and 8.5 years (SD 3.8), respectively (p > 0.999). Conclusion. In this self-matched study, DFOs did not affect subsequent TKA function as clinical outcomes, subjective knee preference, and revision rates were similar in both the DFO-TKA and TKA-only knees at mean 32-year follow-up. Cite this article: Bone Jt Open 2024;5(11):1013–1019


Bone & Joint Open
Vol. 5, Issue 11 | Pages 984 - 991
6 Nov 2024
Molloy T Gompels B McDonnell S

Aims. This Delphi study assessed the challenges of diagnosing soft-tissue knee injuries (STKIs) in acute settings among orthopaedic healthcare stakeholders. Methods. This modified e-Delphi study consisted of three rounds and involved 32 orthopaedic healthcare stakeholders, including physiotherapists, emergency nurse practitioners, sports medicine physicians, radiologists, orthopaedic registrars, and orthopaedic consultants. The perceived importance of diagnostic components relevant to STKIs included patient and external risk factors, clinical signs and symptoms, special clinical tests, and diagnostic imaging methods. Each round required scoring and ranking various items on a ten-point Likert scale. The items were refined as each round progressed. The study produced rankings of perceived importance across the various diagnostic components. Results. In Round 1, the study revealed widespread variability in stakeholder opinions on diagnostic components of STKIs. Round 2 identified patterns in the perceived importance of specific items within each diagnostic component. Round 3 produced rankings of perceived item importance within each diagnostic component. Noteworthy findings include the challenges associated with accurate and readily available diagnostic methods in acute care settings, the consistent acknowledgment of the importance of adopting a patient-centred approach to diagnosis, and the transition from divergent to convergent opinions between Rounds 2 and 3. Conclusion. This study highlights the potential for a paradigm shift in acute STKI diagnosis, where variability in the understanding of STKI diagnostic components may be addressed by establishing a uniform, evidence-based framework for evaluating these injuries. Cite this article: Bone Jt Open 2024;5(11):984–991


Bone & Joint Open
Vol. 5, Issue 11 | Pages 992 - 998
6 Nov 2024
Wignadasan W Magan A Kayani B Fontalis A Chambers A Rajput V Haddad FS

Aims

While residual fixed flexion deformity (FFD) in unicompartmental knee arthroplasty (UKA) has been associated with worse functional outcomes, limited evidence exists regarding FFD changes. The objective of this study was to quantify FFD changes in patients with medial unicompartmental knee arthritis undergoing UKA, and investigate any correlation with clinical outcomes.

Methods

This study included 136 patients undergoing robotic arm-assisted medial UKA between January 2018 and December 2022. The study included 75 males (55.1%) and 61 (44.9%) females, with a mean age of 67.1 years (45 to 90). Patients were divided into three study groups based on the degree of preoperative FFD: ≤ 5°, 5° to ≤ 10°, and > 10°. Intraoperative optical motion capture technology was used to assess pre- and postoperative FFD. Clinical FFD was measured pre- and postoperatively at six weeks and one year following surgery. Preoperative and one-year postoperative Oxford Knee Scores (OKS) were collected.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1206 - 1215
1 Nov 2024
Fontalis A Buchalter D Mancino F Shen T Sculco PK Mayman D Haddad FS Vigdorchik J

Understanding spinopelvic mechanics is important for the success of total hip arthroplasty (THA). Despite significant advancements in appreciating spinopelvic balance, numerous challenges remain. It is crucial to recognize the individual variability and postoperative changes in spinopelvic parameters and their consequential impact on prosthetic component positioning to mitigate the risk of dislocation and enhance postoperative outcomes. This review describes the integration of advanced diagnostic approaches, enhanced technology, implant considerations, and surgical planning, all tailored to the unique anatomy and biomechanics of each patient. It underscores the importance of accurately predicting postoperative spinopelvic mechanics, selecting suitable imaging techniques, establishing a consistent nomenclature for spinopelvic stiffness, and considering implant-specific strategies. Furthermore, it highlights the potential of artificial intelligence to personalize care. Cite this article: Bone Joint J 2024;106-B(11):1206–1215


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1263 - 1272
1 Nov 2024
Amador IE Hao KA Buchanan TR Damrow DS Hones KM Simcox T Schoch BS Farmer KW Wright TW LaMonica TJ King JJ Wright JO

Aims

We sought to compare functional outcomes and survival between non-smokers, former smokers, and current smokers who underwent anatomical total shoulder arthroplasty (aTSA) in a large cohort of patients.

Methods

A retrospective review of a prospectively collected shoulder arthroplasty database was performed between August 1991 and September 2020 to identify patients who underwent primary aTSA. Patients were excluded for preoperative diagnoses of fracture, infection, or oncological disease. Three cohorts were created based on smoking status: non-smokers, former smokers, and current smokers. Outcome scores (American Shoulder and Elbow Surgeons (ASES), Constant-Murley score, Shoulder Pain and Disability Index (SPADI), Simple Shoulder Test (SST), University of California, Los Angeles activity scale (UCLA)), range of motion (external rotation (ER), forward elevation (FE), internal rotation, abduction), and shoulder strength (ER, FE) evaluated at two- to four-year follow-up were compared between cohorts. Evaluation of revision-free survival was performed using the Kaplan-Meier method to final follow-up.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1293 - 1300
1 Nov 2024
O’Malley O Craven J Davies A Sabharwal S Reilly P

Aims

Reverse shoulder arthroplasty (RSA) has become the most common type of shoulder arthroplasty used in the UK, and a better understanding of the outcomes after revision of a failed RSA is needed. The aim of this study was to review the current evidence systematically to determine patient-reported outcome measures and the rates of re-revision and complications for patients undergoing revision of a RSA.

Methods

MEDLINE, Embase, CENTRAL, and the Cochrane Database of Systematic Reviews were searched. Studies involving adult patients who underwent revision of a primary RSA for any indication were included. Those who underwent a RSA for failure of a total shoulder arthroplasty or hemiarthroplasty were excluded. Pre- and postoperative shoulder scores were evaluated in a random effects meta-analysis to determine the mean difference. The rates of re-revision and complications were also calculated.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1321 - 1326
1 Nov 2024
Sanchez-Sotelo J

Periprosthetic joint infection represents a devastating complication after total elbow arthroplasty. Several measures can be implemented before, during, and after surgery to decrease infection rates, which exceed 5%. Debridement with antibiotics and implant retention has been reported to be successful in less than one-third of acute infections, but still plays a role. For elbows with well-fixed implants, staged retention seems to be equally successful as the more commonly performed two-stage reimplantation, both with a success rate of 70% to 80%. Permanent resection or even amputation are occasionally considered. Not uncommonly, a second-stage reimplantation requires complex reconstruction of the skeleton with allografts, and the extensor mechanism may also be deficient. Further developments are needed to improve our management of infection after elbow arthroplasty.

Cite this article: Bone Joint J 2024;106-B(11):1321–1326.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1327 - 1332
1 Nov 2024
Ameztoy Gallego J Diez Sanchez B Vaquero-Picado A Antuña S Barco R

Aims

In patients with a failed radial head arthroplasty (RHA), simple removal of the implant is an option. However, there is little information in the literature about the outcome of this procedure. The aim of this study was to review the mid-term clinical and radiological results, and the rate of complications and removal of the implant, in patients whose initial RHA was undertaken acutely for trauma involving the elbow.

Methods

A total of 11 patients in whom removal of a RHA without reimplantation was undertaken as a revision procedure were reviewed at a mean follow-up of 8.4 years (6 to 11). The range of motion (ROM) and stability of the elbow were recorded. Pain was assessed using a visual analogue scale (VAS). The functional outcome was assessed using the Mayo Elbow Performance Score (MEPS), the Oxford Elbow Score (OES), and the Disabilities of the Arm, Shoulder and Hand questionnaire (DASH). Radiological examination included the assessment of heterotopic ossification (HO), implant loosening, capitellar erosion, overlengthening, and osteoarthritis. Complications and the rate of further surgery were also recorded.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1273 - 1283
1 Nov 2024
Mahmud H Wang D Topan-Rat A Bull AMJ Heinrichs CH Reilly P Emery R Amis AA Hansen UN

Aims

The survival of humeral hemiarthroplasties in patients with relatively intact glenoid cartilage could theoretically be extended by minimizing the associated postoperative glenoid erosion. Ceramic has gained attention as an alternative to metal as a material for hemiarthroplasties because of its superior tribological properties. The aim of this study was to assess the in vitro wear performance of ceramic and metal humeral hemiarthroplasties on natural glenoids.

Methods

Intact right cadaveric shoulders from donors aged between 50 and 65 years were assigned to a ceramic group (n = 8, four male cadavers) and a metal group (n = 9, four male cadavers). A dedicated shoulder wear simulator was used to simulate daily activity by replicating the relevant joint motion and loading profiles. During testing, the joint was kept lubricated with diluted calf serum at room temperature. Each test of wear was performed for 500,000 cycles at 1.2 Hz. At intervals of 125,000 cycles, micro-CT scans of each glenoid were taken to characterize and quantify glenoid wear by calculating the change in the thickness of its articular cartilage.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1240 - 1248
1 Nov 2024
Smolle MA Keintzel M Staats K Böhler C Windhager R Koutp A Leithner A Donner S Reiner T Renkawitz T Sava M Hirschmann MT Sadoghi P

Aims. This multicentre retrospective observational study’s aims were to investigate whether there are differences in the occurrence of radiolucent lines (RLLs) following total knee arthroplasty (TKA) between the conventional Attune baseplate and its successor, the novel Attune S+, independent from other potentially influencing factors; and whether tibial baseplate design and presence of RLLs are associated with differing risk of revision. Methods. A total of 780 patients (39% male; median age 70.7 years (IQR 62.0 to 77.2)) underwent cemented TKA using the Attune Knee System) at five centres, and with the latest radiograph available for the evaluation of RLL at between six and 36 months from surgery. Univariate and multivariate logistic regression models were performed to assess associations between patient and implant-associated factors on the presence of tibial and femoral RLLs. Differences in revision risk depending on RLLs and tibial baseplate design were investigated with the log-rank test. Results. The conventional and novel Attune baseplates were used in 349 (45%) and 431 (55%) patients, respectively. At a median follow-up of 14 months (IQR 11 to 25), RLLs were present in 29% (n = 228/777) and 15% (n = 116/776) of the tibial and femoral components, respectively, and were more common in the conventional compared to the novel baseplate. The novel baseplate was independently associated with a lower incidence of tibial and femoral RLLs (both regardless of age, sex, BMI, and time to radiograph). One- and three-year revision risk was 1% (95% CI 0.4% to 1.9%)and 6% (95% CI 2.6% to 13.2%), respectively. There was no difference between baseplate design and the presence of RLLs on the the risk of revision at short-term follow-up. Conclusion. The overall incidence of RLLs, as well as the incidence of tibial and femoral RLLs, was lower with the novel compared to the conventional tibial Attune baseplate design, but higher than in the predecessor design and other commonly used TKA systems. Cite this article: Bone Joint J 2024;106-B(11):1240–1248


Bone & Joint Open
Vol. 5, Issue 11 | Pages 953 - 961
1 Nov 2024
Mew LE Heaslip V Immins T Ramasamy A Wainwright TW

Aims

The evidence base within trauma and orthopaedics has traditionally favoured quantitative research methodologies. Qualitative research can provide unique insights which illuminate patient experiences and perceptions of care. Qualitative methods reveal the subjective narratives of patients that are not captured by quantitative data, providing a more comprehensive understanding of patient-centred care. The aim of this study is to quantify the level of qualitative research within the orthopaedic literature.

Methods

A bibliometric search of journals’ online archives and multiple databases was undertaken in March 2024, to identify articles using qualitative research methods in the top 12 trauma and orthopaedic journals based on the 2023 impact factor and SCImago rating. The bibliometric search was conducted and reported in accordance with the preliminary guideline for reporting bibliometric reviews of the biomedical literature (BIBLIO).


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1312 - 1320
1 Nov 2024
Hamoodi Z Sayers A Whitehouse MR Rangan A Kearsley-Fleet L Sergeant J Watts AC

Aims

The aim of this study was to review the provision of total elbow arthroplasties (TEAs) in England, including the incidence, the characteristics of the patients and the service providers, the types of implant, and the outcomes.

Methods

We analyzed the primary TEAs recorded in the National Joint Registry (NJR) between April 2012 and December 2022, with mortality data from the Civil Registration of Deaths dataset. Linkage with Hospital Episode Statistics-Admitted Patient Care (HES-APC) data provided further information not collected by the NJR. The incidences were calculated using estimations of the populations from the Office for National Statistics. The annual number of TEAs performed by surgeons and hospitals was analyzed on a national and regional basis.