header advert
Results 1 - 20 of 126
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 51 - 51
17 Apr 2023
Al-Musawi H Sammouelle E Manara J Clark D Eldridge J
Full Access

The aim is to investigate if there is a relation between patellar height and knee flexion angle. For this purpose we retrospectively evaluated the radiographs of 500 knees presented for a variety of reasons. We measure knee flexion angle using a computer-generated goniometer. Patellar height was determined using computer generated measurement for the selected ratios, namely, the Insall–Salvati (I/S), Caton–Deschamps (C/D) and Blackburne–Peel (B/P) indices and Modified I/S Ratio. A search of an NHS hospital database was made to identify the knee x rays for patients who were below the age of forty. A senior knee surgeon (DC) supervised three trainee trauma and orthopaedics doctors (HA, JM, ES) working on this research. Measurements were made on the Insall–Salvati (I/S), Caton–Deschamps (C/D) and Blackburne–Peel (B/P) indices and Modified I/S Ratio. The team leader then categorised the experimental measurement of patients’ knee flexion angle into three groups. This categorisation was according to the extent of knee flexion. The angles were specifically, 10.1 to 20, 20.1 to 30, and 30.1 to 40 degrees of knee flexion. Out of the five-hundred at the start of the investigation, four hundred and eighteen patients were excluded because they had had either an operation on the knee or traumatic fracture that was treated conservatively


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_9 | Pages 26 - 26
1 Oct 2022
Bell J Owen D Meek K Terrill N Sanchez-Weatherby J Le Maitre C
Full Access

Background. An improved understanding of intervertebral disc (IVD) structure and function is required for treatment development. Loading induces micro-fractures at the interface between the nucleus pulposus (NP) and the annulus fibrosus (AF), which is hypothesized to induce a cascade of cellular changes leading to degeneration. However, there is limited understanding of the structural relationship between the NP and AF at this interface and particularly response to load. Here, X-ray scattering is utilised to provide hierarchical morphometric information of collagen structure across the IVD, especially the interface region under load. Methodology. IVDs were imaged using the I22 SAXS/WAXS beamline at Diamond Light Source. Peaks associated with the D-banded structure of collagen fibrils were fitted to quantify their azimuthal distribution, as well the magnitude and direction of internal strains under static and applied strain (0–20%). Results. IVD tissue regions exhibited structural “AF-like” and “NP-like” fingerprints. Demonstrating high internal strains on collagen fibres particularly within the NP region of the disc. AF and NP regions showed distinct collagen orientation and internal strains with an apparent lack of bracing structure seen at the interface between the differential mechanical tissues. X-ray scattering under tensile strain provided structural information at high resolution, with clear differences observed between normal and degenerate discs under load. Conclusion. X ray scattering has been utilised to develop an improved understanding of collagen structure across the intervertebral disc which can be utilised to gain an increased understanding of load induced propagation of micro fissures and disc degeneration. Conflict of Interest: No conflict of interest. Funding: BioPro Network, UCL for funding this study through support from the MRC (MR/R025673/1)


Bone & Joint 360
Vol. 11, Issue 4 | Pages 17 - 21
1 Aug 2022


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 63 - 63
1 Nov 2021
Visscher L White J Tetsworth K McCarthy C
Full Access

Introduction and Objective. Malunion after trauma can lead to coronal plane malalignment in the lower limb. The mechanical hypothesis suggests that this alters the load distribution in the knee joint and that that this increased load may predispose to compartmental arthritis. This is generally accepted in the orthopaedic community and serves as the basis guiding deformity correction after malunion as well as congenital or insidious onset malalignment. Much of the literature surrounding the contribution of lower limb alignment to arthritis comes from cohort studies of incident osteoarthritis. There has been a causation dilemma perpetuated in a number of studies - suggesting malalignment does not contribute to, but is instead a consequence of, compartmental arthritis. In this investigation the relationship between compartmental (medial or lateral) arthritis and coronal plane malalignment (varus or valgus) in patients with post traumatic unilateral limb deformity was examined. This represents a specific niche cohort of patients in which worsened compartmental knee arthritis after extra-articular injury must rationally be attributed to malalignment. Materials and Methods. The picture archiving system was searched to identify all 1160 long leg x ray films available at a major metropolitan trauma center over a 12-year period. Images were screened for inclusion and exclusion criteria, namely patients >10 years after traumatic long bone fracture without contralateral injury or arthroplasty to give 39 cases. Alignment was measured according to established surgical standards on long leg films by 3 independent reviewers, and arthritis scores Osteoarthritis Research Society International (OARSI) and Kellegren-Lawrence (KL) were recorded independently for each compartment of both knees. Malalignment was defined conservatively as mechanical axis deviation outside of 0–20 mm medial from centre of the knee, to give 27 patients. Comparison of mean compartmental arthritis score was performed for patients with varus and valgus malalignment, using Analysis of Variance and linear regression. Results. In knees with varus malalignment there was a greater mean arthritis score in the medial compartment compared to the contralateral knee, with OARSI scores 5.69 vs 3.86 (0.32, 3.35 95% CI; p<0.05) and KL 2.92 vs 1.92 (0.38, 1.62; p<0.005). There was a similar trend in valgus knees for the lateral compartment OARSI 2.98 vs 1.84 (CI −0.16, 2.42; p=0.1) and KL 1.76 vs 1.31 (CI −0.12, 1.01; p=0.17), but the evidence was not conclusive. OARSI arthritis score was significantly associated with absolute MAD (0.7/10mm MAD, p<0.0005) and Time (0.6/decade, p=0.01) in a linear regression model. Conclusions. Malalignment in the coronal plane is correlated with worsened arthritis scores in the medial compartment for varus deformity and may similarly result in worsened lateral compartment arthritis in valgus knees. These findings support the mechanical hypothesis that arthritis may be related to altered stress distribution at the knee, larger studies may provide further conclusive evidence


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 91 - 91
1 Mar 2021
Martin R Critchley R Anjum S
Full Access

Neck of femur fractures are a common presentation and certain patients can be managed with a total hip replacement. To receive a total hip replacement the pelvic X-rays should be templated as per AO guidelines and a common way this is performed is by including a calibration marker on the X-ray. The aim of this study is to assess and improve upon the use of the calibration marker. Details of patients admitted with a neck of femur fracture from January 1st 2018 until December 31st 2018 were gathered and used to review each initial X-ray and determine if a calibration marker was included. 376 patients were admitted with a neck of femur fracture over the one year period. 36% of patients did not have a calibration marker on their initial pelvic X-ray and 11% did not have a chest X ray. 215 patients had an intracapsular fracture and 39 went on to have a total hip replacement. 12 patients were lacking a calibration marker on their original X ray and required a repeat X ray. After a poster was placed in the radiographer booth acting as a visual aid, the use of a calibration marker improved from 62% to 70%. Calibration markers are useful tools which can aid the pre-operative planning for hip replacement surgeries shortening operative time, increase precision and reduce prosthetic loosening, lowers the risk of peri-prosthetic fractures, reduce leg length discrepancy and ensure the required implants are available. If a marker is not included on the initial X-rays, and a patient has a neck of femur fracture which requires a joint replacement, they may have to have additional X-rays performed as was the case for 12 patients in this study. This process leads to possible delays in surgery, additional radiation and increased healthcare costs


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 51 - 51
1 Dec 2020
Khan MM Pincher B Pacheco R
Full Access

Aims and objectives

Our aim was to evaluate the indications for patients undergoing magnetic resonance imaging (MRI) of the knee prior to referral to an orthopaedic specialist, and ascertain whether these scans altered initial management.

Materials and Method

We retrospectively reviewed all referrals received by a single specialist knee surgeon over a 1-year period. Patient demographics, relevant history, examination findings and past surgical procedures were documented. Patients having undergone MRI prior to referral were identified and indications for the scans recorded. These were reviewed against The NHS guidelines for Primary Care Physicians to identify if the imaging performed was appropriate in each case.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 74 - 74
1 Apr 2019
Micera G Moroni A Orsini R Sinapi F Fabbri D Acri F Miscione MT Mosca S
Full Access

Objectives. Total hip arthroplasty (THA) is one of the most successful surgical procedures; several bearing technologies have been used, however none of these is optimal. Metal on polycarbonate-urethane (PCU) is a new bearing technology with several potential advantages: PCU is a hydrophilic soft pliable implant quite similar in elasticity to human cartilage, offers biostability, high resistance to hydrolysis, oxidation, and calcification, no biodegradation, low wear rate and high corrosion resistance and can be coupled with large metal heads (Tribofit Hip System, THS). The aim of this prospective study was to report the survivorship and the clinical and radiographic outcomes and the metal ions dosage of a group of patients operated with metal on PCU arthroplasty featuring large metal diameter heads, at 5 years from surgery. Study Design & Methods. 68 consecutive patients treated with the THS were included. The patients have been contacted by phone call and invited to return to our centre for clinical (Oxford Hip Score, OHS, and Harris Hip Score, HHS), radiographic exam and metal ion levels evaluation. All the patients were operated with uncemented stems. Results. The survival rate is 100% and no major complications were seen. The average preoperative OHS was 17 (6–34), at follow-up it was 44 (40–48). The average preoperative HHS was 48 (12–76), at follow-up it was 93 (84–100). On the x rays taken at follow-up, no signs of periprosthetic bone rarefaction and/or osteolysis were seen. No signs of PCU liner wear were visible. At follow up mean Co serum level was 0.52 ng/mL (<0.1–2.5, sd 0.5), mean Cr level was 0.27 ng/mL (0.1–2.2, sd 0.2). In this prospective study at a mean follow up of 5 years, all implants were well functioning, with no radiological signs of loosening and normal serum levels of cobalt and chrome. Although large diameter metal heads and metal sleeve were used no trunnionosis occurred. Conclusions. We believe that these positive outcomes are due the positive biomechanical characteristics of PCU. These results need to be confirmed at a longer follow up and in a more active younger patient population


Introduction. Literature describes pelvic rotation on lateral X rays from standing to sitting position. EOS full body lateral images provide additional information about the global posture. The projection of the vertical line from C7 (C7 VL) is used to evaluate the spine balance. C7 VL can also measure pelvic sagittal translation (PST) by its horizontal distance to the hip center (HC). This study evaluates the impact of a THA implantation on pelvic rotation and sagittal translation. Materials and Method. Lumbo-pelvic parameters of 120 patients have been retrospectively assessed pre and post- operatively on both standing and sitting acquisitions (primary unilateral THA without complication). PST is zero when C7VL goes through the center of the femoral heads and positive when C7VL is posterior to the hips' center (negative if anterior). Three subgroups were defined according to pelvic incidence (PI): low PI <45°, 45°<normal PI<65° or high PI>65°. Results. Pre-operatively PST standing was −0.9 cm (SD 4.5; [−15.1 to 7.2]) and PST sitting was 1.3cm (SD 3.3; [−7.7 to 11.8]). The overall mean change from standing to sitting was 2.2 cm ([−7.2 to 17.4]) (p<0.05). Post-operatively PST standing was 0.2 cm (SD 4.7; [−17 to 8.1]) and PST sitting was 1.4cm (SD 3.5; [−7.3 to 10.4]). The overall mean change from standing to sitting was 1.2 cm ([−14.2 to 22.4]) (p<0.05). In low PI group pre and post-operatively, PST increased significantly from standing to sitting (p<0.05; with HC going anterior to C7VL). When comparing pre and post operative changes, standing PST significantly increased (p=0.001). Pre to postoperative PST variation (sitting-standing) decreased significantly (p=0,01). In normal PI group pre-operatively, PST increased from standing to sitting (p=0.004). When comparing pre and postoperative changes, PST increased (p=0.006). Pre to postoperative PST variation (sitting-standing) decreased significantly (p=0,04). In high PI group pre and post operatively, PST increased from standing to sitting (p=0.034) while there are no significant changes from pre to post-operative status in standing and in sitting. Discussion. Anteroposterior pelvic tilt is not the only adaptation strategy for postural changes from standing to sitting positions. Anteroposterior pelvic translation (quantified by PST) is an important adaptation mechanism for postural changes. Comparison of pre and post-operative values of PST points out the importance of pelvic translation for low and standard PI patients after THA. The anteroposterior translation appears to change significantly in different functional positions pre and post operatively. This is an important variable to consider when assessing the patients' posture change or investigating the causes of the hip dislocation after total hip arthroplasty or spinal fusion. Conclusion. Pelvic translation must be considered as a significant mechanism of adaptation after THA. Further studies are needed to study the impact on subluxation or dislocation


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 117 - 117
1 Jun 2018
Whiteside L
Full Access

Stems are a crucial part of implant stabilization in revision total knee arthroplasty. In most cases the metaphyseal bone is deficient, and stabilization in the diaphyseal cortical bone is necessary to keep the implant tightly fixed to bone and to prevent tilt and micromotion. While sleeves and cones can be effective in revision total joint arthroplasty, they are technically difficult and may lead to major bone loss in cases of loosening or infection, especially if the stem is cemented past the cone. A much more conservative method is to ream the diaphysis to the least depth possible to achieve tight circumferential fixation, and to apply porous augments to the undersurface of the tibial tray or inner surface of the femoral component to allow them to bottom out against the bone surface and apply compressive load. If a robust, strong taper, stem and component combination is used, rim contact on only one side is necessary to achieve rigid permanent fixation. Porous and non-porous stems are available. The non-porous stems should have a spline surface that engages the diaphyseal bone and achieves rigid initial fixation but does not provide long-term axillary support. In that way the porous rim-engaging surface can bear compressive load and finally unload the stem and taper junction. Correctly designed stems do not stress relieve unless they are porous-coated. In situations where metaphyseal bone is not available, porous-coated stems that link to hinge prostheses are a very important part of the armamentarium in complex revision arthroplasty. Use of stems requires experience and special technique. Slight underreaming and initial scratch fit are necessary techniques. This does not result in tight fixation every time because split of the cortex does occasionally occur. In most cases these splits do not need to be repaired, but when there is a question, an intra-operative x ray should be taken and the surgeon should be prepared to repair the fracture. Stems are an essential part of revision total knee arthroplasty. A tightly fit stem in the diaphysis is necessary for fixation when metaphyseal bone is deficient. No amount of cement pressed into the deficient metaphyseal bone will substitute for rigid stem fixation


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 115 - 115
1 Jan 2017
Gunzel E Gindraux F Barnouin L
Full Access

Amniotic membrane (AM) and amnion/chorion foetal membranes (ACM) are mainly composed of collagen & laminin layers and constitute relatively new materials to the dental market. They have proven effective for periodontal treatments such as Guided Tissue Regeneration (GTR) [1–3]. Based on our expertise in the field of lyophilisation & securisation of human bone allograft (Phoenix® process), we aimed to develop our own process applied to ACM and to control its in vivoefficacy in GTR indication. Human placentas were donated under informed consent. ACM were separated from placenta and processed with a proprietary AMTRIX (TBF) Process. Resulting product was called ACMTRIX. The effectiveness of ACMTRIX in GTR was evaluated using an in vivorat calvaria defect model as followed:. Empty defect (2 animals),. ACMTRIX apposed onto the defect (4 animals),. 3 Bone substitutes (allogenic – mineralized cortical bone powder (Phoenix®); demineralized cancellous bone powder mixed with hydroxyapatite and demineralized bone matrix (DBM) cancellous block) filled in the defect and covered by ACMTRIX (4 animals). One animal per study group was sacrificed after 8 weeks, all others after 8 weeks. Evaluations were performed by: macroscopic observations, X Ray micro-CT, and histological analysis. For all groups using ACMTRIX, no major sign of inflammation were observed macroscopically and histologically. Moreover, bone tissue was already mature from 8 weeks and bone filling was slight to moderate. The higher mean rate of mineralization was obtained for the group associating DBM cancellous block + ACMTRIX. Although a xenogenic material, ACMTRIX was very well integrated without significant inflammatory reaction compared to empty defect and fully integrated in subcutaneous area. The mineralization was superior with DBM cancellous block probably thanks to the stabilization of the material in the defect. Used alone, ACMTRIX has no osteogenic potential. In conclusion, ACMTRIX has the potential to function as barrier for GTR and the unique properties associated with this material can augment its potential as a matrix for periodontal regeneration


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_19 | Pages 15 - 15
1 Nov 2016
Sinclair V Walsh A Watmough P Henderson A
Full Access

Introduction. Ankle fractures are common injuries presenting to trauma departments and ankle open reduction and internal fixation (ORIF) is one of the first procedures targeted in early orthopaedic training. Failure to address the fracture pattern with the appropriate surgical technique and hardware may lead to early failure resulting in revision procedures or premature degenerative change. Patients undergoing revision ORIF are known to be at much greater risk of complications, and many of these secondary procedures may be preventable. Method. A retrospective analysis of all patients attending our unit for ankle ORIF over a two year period was undertaken. Patients were identified from our Bluespier database and a review of X rays was undertaken. All patients undergoing re-operation within eight weeks of the primary procedure were studied. The cause of primary failure was established and potential contributing patient and surgical factors were recorded. Results. 236 patients undergoing ankle ORIF were identified. 13 patients (5.5%) returned to theatre for a secondary procedure within eight weeks. Within this group, 7 (54%) patients returned for treatment of a neglected or under treated syndesmotic injury, 3 (23%) for complete failure of fixation, 2 (15%) with wound problems and 1 (8%) for medial malleoulus mal-reduction. Of the patient group, 5 (38%) were known type 2 diabetics. Consultants performed 2 (15%) of procedures, supervised registrars 5 (39%) and unsupervised registrars 6 (46%) operations. Conclusion. Errors are being made at all levels of training in applying basic principles such as restoring fibula length and screening the syndesmosis intra-operatively. Appropriate placement and selection of hardware is not always being deployed in osteopenic bone resulting in premature failure of fixation and fracture patterns are not being fully appreciated. Patients are undergoing preventable secondary procedures in the operative treatment of ankle fractures


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_14 | Pages 3 - 3
1 Jul 2016
Ramesh K Baumann A Makaram N Finnigan T Srinivasan M
Full Access

Despite the high success rates of Reverse Shoulder replacements, complications of instability & scapular notching are a concern. Factors reducing relative motion of implant to underlying bone which include lateral offset to centre of rotation, screw & central peg insertion angle and early osteo-integration are maximized in the Trabecular Metal Reverse total shoulder system. We present clinico-radiological outcomes over 72 months. Analysis of a single surgeon series of 140 Reverse total shoulder replacements in 135 patients was done. Mean age was 72(range 58– 87 yrs); 81 females: 54 males. Indications were Rotator cuff arthropathy {n= 88} (63%); Osteo-arthritis with dysfunctional cuff {n= 22}(15%); post-trauma{n=23} (15%); revision from hemiarthroplasty {n=3} (2.4%) and from surface replacement {n=4} (2.8%). All patients were assessed using pre-operative Constants and Oxford scores and clinical & radiographic reviews with standard X-Rays at 6 weeks, 3, 6,12 months and yearly thereafter. X rays included an AP view in 45 degrees of external rotation and modified axillary view. Inferior Scapular notching using the Nerot-Sirveaux grades and Peg Glenoid Rim Distance were looked into by a consultant musculoskeletal radiologist/ Orthopaedic surgeon/ Senior Fellow (post CCT) or a specialist Trainee (ST4 and above). Pain on the visual analogue scale decreased by 98% (9.1 to 0.8) (p<0.01). Constant score improved by 81.8% (12.4 to 68.1) (p<0.05), Oxford shoulder score by 76.7% (56 to 13) (p<0.05). 95.6% of Humeral stems had no radiolucent lines and 4.4% had < 2mm of lucency. Scapular notching was calculated using Sirveaux grades with Peg scapular base angle distance (PSBA) measurements on PACS with Siemens calibration (grade 1= 4 (2.8%); grade 2 =1; grade 3 =0; grade 4=0). 3.57% showed radiographic signs of scapular notching at 72 months. Range of Peg Glenoid Rim Distance was 1.66 to 2.31 cm. Power analysis showed 65 patients were needed to have an 80% power to detect relation of Peg Glenoid Rim Distance to Scapular notching. A likelihood ratio test from Logistic regression model to check correlation of Peg Glenoid Rim Distance to Scapular notching gave a p value of 0.0005. A likelihood ratio from Logistic regression gave a p value of 0.0004 for Infraglenoid Scapular spurs. Highest incidence of spurring was seen in Reverse Total Shoulder Replacements done for Trauma and lowest in patients who got the procedure for Osteoarthritis. Complications included two glenosphere revisions; two stitch abscesses and two Acromial fractures in patients who had a fall two years after the procedure. Improved surgical outcomes can be attributed to surgical technique and implant characteristics. Trabacular metal promotes early osteointegration which resists shearing action of Deltoid on Glenoid component. This allows early mobilisation. Deltoid split approach preserves integrity of Subscapularis and Acromial osteotomy and lateral clavicle excision improve exposure and prevent Acromion fracture. Positioning the Glenoid component inferiorly on the Glenoid decreases incidence of Scapular notching. Our mid-term validated outcomes are promising with only 3.57% Grade I/II radiographic signs of scapular notching. Long term studies (10 year follow ups) are necessary to confirm its efficacy


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 1 - 1
1 Jan 2016
Shah A
Full Access

Introduction. One of the important criteria of the success of TKR is achievement of the Flexion ROM. Various factors responsible to achieve flexion are technique, Implant and patient related. Creation of the Posterior condylar offset is one such important factor to achieve satisfactory flexion. Aim. To correlate post op femoral condylar offset to final flexion ROM at 1 yr. post op. Methods. This is a clinico-radiological study of the cases done prospectively between September 2011 and August 2012. Inclusion criteria:. All patients undergoing Bilateral TKRs and have agreed for the follow up at 1 yr. Exclusion criteria:. Patients who had previous bony surgery on lower end femur. Patients with previous fracture of lower end femur. All the patients had PS PFC Sigma (De Puy, Warsaw) components cemented. ROMs were measured at 6 weeks, 3 months, & 1 year post op. The last reading was taken as final flexion ROM as measured by a Physiotherapist with the help of a Goniometer. Results. We had 21 cases of Bilateral TKRs who satisfied our criteria. Pre and post op femoral condylar offset was measured in mm. on lateral x ray. Pre and post op flexion was measured. Results showed that variation in the posterior femoral offset by > 3mm in post op x ray was related to loss of flexion of an average 21 deg. (16 – 24 degrees). Greater the deflection from the normal offset, greater was the loss of flexion. These patients also showed lesser improvement in KSS functional score. Discussion. Flexion is one of the most important yardsticks for the measurement of success of TKR. This factor is more important more so in Asian population. Literature has shown that three important determinants for good flexion are…. Posterior Condylar Offset Restoration. Tibial slope restoration. Femoral Roll back in flexion. An increased offset permits greater flexion before impingement between the tibial insert and the femur. In our study we kept Tibial slope and Femoral Roll back constant by using the same prosthesis. The femoral condylar offset changed as per the size of the AP femoral cutting block. (Anterior referencing guide used). Overresection of the posterior condyles reduced the posterior femoral condylar offset and hence significant loss of post op flexion. The shorter posterior condyle of smaller femoral component can increase the potential for bone impingement proximal to the posterior condyles. In our study the opposite side replaced knee acted as a control. It is generally stated that after a TKR flexion can improve upto 1 year and hence was taken as final possible flexion. Conclusion. Keeping Tibial slope and Femoral roll back constant during the surgery, posterior condylar offset restoration within 3 mm of its original pre op offset was necessary to achieve satisfactory flexion at 1 year. Undersizing the femoral component to achieve more flexion is perhaps suboptimal. Appropriate AP femoral sizing is a must to restore the normal offset


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 76 - 76
1 Jan 2016
Trabish M
Full Access

Hypothesis. The use of cartilage compensated virtual standing CT images for pre surgical planning improves the reliability of preoperative planning. Materials and Method. Sampling included in this study were > 62 years of age (mean age 58.17 yrs ±3.54 yrs, range 55–62) with symptomatic isolated medial osteoarthritis, genu varum (mean varus 5.6°±2.6 °, range 2.1°–8.6°), good range of motion (flexion > 90° and flexion contracture < 10°) and with minimal ligamentous instability. All subjects had obtained a pre-op CT scan, MRI scan and weight-bearing long bone x ray. Post-op CT and long standing x-rays were taken prior to hospital discharge. A virtual software suite (HTO-OP3D, Zapalign Inc, Seoul, Korea) was utilised to determine an optimal osteotomy site, hinge location and a gap necessary to achieve the targeted virtual passing point. Prerequisite to performing the necessary calculations a virtual standing pose for each patient specific bone models was created using the following steps. To transfer the pre surgical plan intra-operatively, a customised alignment jig was manufactured. Results. Analysing the data using three dimensional imagery the femorotibial angle was corrected from a mean varus 5.5° ±2.3 ° (range 2.1°–8.6°) to a mean valgus 4.1° ±1.1° (range 2.9°– 6.1°). There was no statistical difference [p = 0.514] between the virtual simulatedpre-op valgus vs actual post-op valgus results extrapolated from the post op CT data {−0.18° ±0.3° (range −0.7°–1.0°)}. Analysing the same parameters using two dimensional standard X-rays, the femorotibial angle was corrected from a mean varus 6.6° ±2.9 ° (range 3.4°–10.6°) to a mean valgus 3.9° ±1.2° (range 2.9°–6.1°) respectively showing no statistical difference in average change in alignment measured using both modalities [p = 0.13]. The mean opening gap calculated using the three dimensional imagery vs two dimensional were 8.2mm ±2.9mm (range 5mm – 12mm) and 13.3mm ±3.3mm (range 10.2mm – 17.6mm) respectively, the difference between these data sets being statistically different [p = 0.03059]. The post operative evaluation of the posterior slope showed no statistical difference [p = 0.371] between the native slope {11.6° ±3.7° (range 5.3°–15.0°)} vs the post operative tibial slope {11.6° ±3.6° (range 6.2°–16.1°)} respectively indicating that the patients slope was well preserved. Conclusion. The use of patient specific bone model images superimposed into a cartilage compensated full extension simulated weight bearing pose and used to calculate the femorotibial corrective alignment and opening gap produces predictable results that is not influenced by the condition of the patients soft tissue. Corrective angles and opening gap calculations using two dimensional weight bearing X-rays does not always relate to good surgical outcome, primarily due to the influence of laxity on the alignment in standing pose. Furthermore, a patient specific clamping type surgical guide is effective to implement the pre surgical and aid in maintaining the tibial slope


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 17 - 17
1 Nov 2015
Jeans E Syed A Mohammed A
Full Access

Introduction. Magnetic resonance arthrogram (MRA) is the investigation of choice in young adults with symptoms of femero acetabular impingement. The aim of the study is to assess the accuracy of MRA when correlated with surgical findings on hip arthroscopy. Materials and Method. Between June 2007 and January 2014, 136 patients had MRA followed by subsequent arthroscopy at our institution. The radiology information system was used to gather MRA data. All scans were reported by a consultant radiologist with a specialist interest in musculoskeletal radiology. Patient records were reviewed to gather surgical data. Assessment was made of labral injury, Camshaft (CAM) or Pincer lesion and degeneration of the cartilage. Results. Mean age at MRA was 34.5 years with a 2.5:1 female to male ratio. For labral pathology sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 89, 100, 100 and 22% respectively. For CAM (62, 80, 79 and 64% respectively) and Pincer lesions (15, 84, 81 and 18% respectively). MRA was specific for picking up Grade 3/4 degenerate changes in the articular cartilage (92.2%) but was not as sensitive (60%), PPV 55 and NPV 94. Conclusion. These findings demonstrate that MRA is a sensitive and specific imaging modality for assessing the labrum and articular surface, but not as good for assessing CAM and Pincer lesions. This could be due to the static nature of the MRA or a lack of firm definition as to what constitutes a CAM or Pincer lesion leading to under reporting. This maybe better assessed with plane X ray or Computed tomography with 3 dimensional reconstruction. Further to this it would be interesting to combine the plane X ray and MRA finding and see if sensitivity and specificity was improved


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 7 - 7
1 Sep 2014
Ajai A
Full Access

The lack of a universal, consistent protocol for the subjective, objective and radiographic evaluation of these injuries has hampered the comparison of results. Methods. 45 patients with complex fractures of the calcaneus were included in this prospective study, which was undertaken from July 2003 to December 2005. The fracture classification of Essex-Lopresti was used. We also observed the extent of secondary fracture lines extending from the primary shear line (on axial and external oblique plain radiographs) to establish comminution. The external oblique view for subtalar joint was performed with the patient supine, the knee at about 60 degree of flexion and the limb rotated externally 45 degree with a vertical X ray beam. All of these patients were managed by an external fixator using the principle of ligamentotaxis. Patients were evaluated by AOFAS. Results. We identified two broad patterns of secondary lines on plain X-rays:. with anterior secondary fracture lines and. with posterior secondary fracture lines. There were 20 cases of tongue type and 25 of joint depression type fracture pattern by the Essex-Lopresti classification. Forty two (93.4%) patients had fractures with posterior secondary fracture line and 3 (6.7%) patients had anterior secondary lines. The calcaneo-cuboid type of anterior secondary line pattern was present in 2 (4.5%) cases, and the plantar type in only 1 (2.5%) case. We observed posterior secondary line Type A pattern in 2 (4.5%) cases, depression / central depression type B in 20 (44.5%) cases, tongue shaped Type C pattern in 16 (36.5%) cases and Type D severely comminuted fracture line pattern in 4 (8.7%) cases. Conclusion. Comminution was significantly associated with prognosis and final outcome. Evaluation of secondary fracture lines corresponds with comminution of fractures of the calcaneus and the final outcome of these fractures. NO DISCLOSURES


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 277 - 277
1 Jul 2014
Bhushan P Varghese M
Full Access

Summary. There is little consensus regarding the regime for treatment of tuberculosis of spine, although WHO has laid down guidelines couple of years back classifying spinal tuberculosis in Category 1. This study proves the efficacy of WHO regime in spinal tuberculosis by clinico-radiological evaluation. Introduction. The medical fraternity is divided over the duration of chemotherapy in cases spinal tuberculosis. WHO clearly recommend spinal tuberculosis under Category I, but not accepted by most clinicians. Patient and Methods. In this prospective study during the period between August 2005 and July 2012, a total of 76 cases were diagnosed and evaluated clinico-radiologically to test the efficacy of WHO protocol (2HRZE+4HR) in our hospital with a mean follow up of 50 months (30 – 80 months). Results. Spinal tuberculosis was seen in 56% of all osteoarticular tuberculosis. Maximum population was between 11–50 years, females were involved more than males (66%), and regional distribution was different in males (Lumbar) and females (Thoracic). Skip and multifocal lesions were seen in 13% (6 cases), more common in immune compromised cases. Pain was the most common symptom (95%) followed by constitutional symptoms. Radiographic changes were nonspecific, appear late and suggestive of tuberculosis in 53%case, MRI is very useful in diagnosing in 95% cases especially when X ray is contributory. ESR is useful tool for follow up of patients, elevated in 94%cases. Results were evaluated on clinical, hematological and radiological basis. Of the total 64cases (after dropouts, lost in follow up, mortality), 50 patients (78%) received treatment for 6 months and14 cases for more than 6months (P value<0.001). No MDR cases were present. In 50 patients fall in ESR at the end of 2 months was found to be statistically significant (P value<0.05) and hence were given a treatment for 6 months, the fall at the end of 6 months was highly significant (P value<0.001). In rest of the 14 cases the duration of treatment was given for more than 6 months as the trend of fall of ESR was not significant. MRI changes were assessed in the form of osteitis, osteitis with discitis, abscess formation and granulation tissue on initiation of treatment, completion of treatment and 6 months after completion of treatment. Conclusion and Discussion. The experience shows that spinal tuberculosis is common in a tertiary health care centre in India with diagnosis possible by combination of clinical evaluation and radiological evaluation. Statistical significance was found in clinical symptoms, ESR trends and MRI evaluation in cases receiving 6 months of chemotherapy. With this study, WHO short course chemotherapy was found to be effective in spinal tuberculosis, with no relapse over a period of 6 years


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 206 - 206
1 Jul 2014
Senthilkumar V Goel S Gupta K
Full Access

Introduction. Stem cells have the capacity for self renewal and capability of differentiation into various cell lineages. Non union remains a clinically important problem in orthopaedic surgery. Method. We randomly assigned 45 patients into 3 groups. Test group: 15 patients in which mesenchymal stem cells prepared by conventional density-gradient centrifugation using ficoll-hypaque solution were injected (n=15), control A: 15 patients in which autogenous bone marrow aspirate were injected (n=15), control B: 15 patients in which neither the stem cell nor bone marrow injection given, symptomatically treated(n=15). Ultra sound and x rays were performed at follow up of 6, 12, 18, 24 weeks and comparison done. Results. Stem cell group: 12 patients out of 13 followed showed excellent results and 1 patient showed good result. Control A bone marrow injection group: 6/15 patients showed excellent results and 3 patients showed good results. Control B: only 2/15 patients showed excellent results. In fracture gap 4–5mm the stem cell group showed union in most of the patients. In control A and control B patients with same fracture gap failed to unite. Conclusion. In fracture situations, in which a manipulation or augmentation of natural healing mechanisms is needed to regenerate larger quantities of new bone Stem cells play a part. This technique of percutaneous stem cell injection provides a very safe, easy, non immunogenic, non invasive and reliable alternative to open bone grafting. This one-stage isolation procedure in comparison to the ex-vivo expansion of autologous cells from bone marrow/embryonic cells reduces the cost and infection rates related to the extra personal need and extended time required for the expansion. Summary. Stem cells have potential to enhance bone healing in non union of fractures


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 528 - 528
1 Dec 2013
Shah A
Full Access

Introduction:. One of the important criteria of the success of TKR is achievement of the Flexion ROM. Various factors responsible to achieve flexion are technique, Implant and patient related. Creation of the Posterior condylar offset is one of the important factors to achieve satisfactory flexion. Aim:. To correlate post op femoral condylar offset to final flexion ROM at 1 yr. post op. Methods:. This is a clinico-radiological study of the cases done prospectively between September 2011 and August 2012. Inclusion criteria:. All patients undergoing Bilateral TKRs and have agreed for the follow up at 1 yr. Exclusion criteria: . 1). Patients who had previous bony surgery on lower end femur. 2). Patients with previous fracture of lower end femur. All the patients had PS PFC Sigma (De Puy, Warsaw) components cemented. ROMs were measured at 6 weeks, 3 months, & 1 year post op. The last reading was taken as final flexion ROM as measured by an independent Physiotherapist with the help of a Goniometer. Results:. We had 21 cases of Bilateral TKRs who satisfied our criteria. Pre and post op femoral condylar offset was measured in mm. on lateral x ray. Pre and post op flexion was measured. Results showed that variation in the posterior femoral offset by > 3 mm in post op x ray was related to loss of flexion of an average 21 deg. (16–24 degrees). Greater the deflection from the normal offset, greater was the loss of flexion. These patients also showed lesser improvement in KSS functional sco. Discussion:. Flexion is one of the most important yardsticks for the measurement of success of TKR. This factor is more important more so in Asian population. Literature has shown that three important determinants for good flexion are…. . 1). Posterior Condylar Offset Restoration. 2). Tibial slope restoration. 3). Femoral Roll back in flexion. An increased offset permits greater flexion before impingement between the tibial insert and the femur. In our study we kept Tibial slope and Femoral Roll back constant by using the same prosthesis. The femoral condylar offset changed as per the size of the AP femoral cutting block. (Anterior referencing guide used). Overresection of the posterior condyles reduced the posterior femoral condylar offset and hence significant loss of post op flexion. The shorter posterior condyle of smaller-sized femoral component can increase the potential for bone impingement proximal to the posterior condyles. In our study the opposite side replaced knee acted as a control and hence eliminating patient bius. It is generally stated that after a TKR flexion can improve upto 1 year and hence that was taken as final possible flexion. Conclusion:. Keeping Tibial slope and Femoral roll back constant during the surgery, posterior condylar offset restoration within 3 mm of its original pre op offset was necessary to achieve satisfactory flexion at 1 year. Undersizing the femoral component to achieve more flexion is perhaps suboptimal. Appropriate AP femoral sizing is a must to restore the normal offset


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 1 - 1
1 Dec 2013
Abdulkarim A Elsibaei A Jackson B Riordan D Rice J
Full Access

Introduction. Proper femoral reaming is a key factor for a successful outcome in cementless hip arthroplasty. Good quality reaming minimizes risks of intra-operative femoral fracture during reaming and prevents poor fitting of the implant which can lead to subsidance of the stem postoperativly. Determining the quality of reaming is largely a subjective skill and dependant on the surgeon's experience with no documented intraoprative method to assess it objectively. Method. We recorded and analysed the frequencies of sound signals recorded via a bone conduction microphone during reaming of the femoral canal in a series of 28 consecutive patients undergoing uncemented total hip replacement performed by same surgeon. Hammaring sound frequencies and intensity were analysed by mean of computer software. The relationship between the patterns of the recorded reaming sound frequencies compared with surgeon judgment of the reaming quality intraoparativly and post operative x rays. All patients were followed up clinically and radiologically for 2 years after surgery to determine the integrity of the fix and to evaluate the stability of the prosthesis. Results. There was a consistent pattern of frequency changes detected in all cases regardless of gender, age, bone density size of reamer etc. Our results showed that the resonances in the femur can be accurately recorded during canal reaming and proved that there is a definite increase in the amplitude of sound frequencies between 600 and 1000 Hz when the tension of the reamer moves from loose to tight during hammering. Adding all of the dB values between 600 to 1000 Hz for the loose tension sound and comparing this to the total for the tight tension sound showed an average of 449.6% increase. Our Analysis of the sound signals changes was comparable to the adequacy of the reaming postoperatively. Conclusion. There are identifiable audio frequency patterns changes associated with satisfactory reaming of the femoral canal. Our findings may pave the way for the development of a real-time intraoperative reaming audio analyser which can guide the surgeon to the optimal reaming tension