This study aimed to investigate the optimal sagittal positioning of the uncemented femoral component in total knee arthroplasty to minimize the risk of aseptic loosening and periprosthetic fracture. Ten different sagittal placements of the femoral component, ranging from -5 mm (causing anterior notch) to +4 mm (causing anterior gap), were analyzed using finite element analysis. Both gait and squat loading conditions were simulated, and Von Mises stress and interface micromotion were evaluated to assess fracture and loosening risk.Aims
Methods
The aim of this study was to compare the migration of the femoral component, five years postoperatively, between patients with a highly cross-linked polyethylene (HXLPE) insert and those with a conventional polyethylene (PE) insert in an uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary aims included clinical outcomes and patient-reported outcome measures (PROMs). We have previously reported the migration and outcome of the tibial components in these patients. A double-blinded randomized controlled trial was conducted including 96 TKAs. The migration of the femoral component was measured with radiostereometry (RSA) at three and six months and one, two, and five years postoperatively. PROMs were collected preoperatively and at all periods of follow-up.Aims
Methods
The mean age of patients undergoing total knee arthroplasty (TKA) has reduced with time. Younger patients have increased expectations following TKA. Aseptic loosening of the tibial component is the most common cause of failure of TKA in the UK. Interest in cementless TKA has re-emerged due to its encouraging results in the younger patient population. We review a large series of tantalum trabecular metal cementless implants in patients who are at the highest risk of revision surgery. A total of 454 consecutive patients who underwent cementless TKA between August 2004 and December 2021 were reviewed. The mean follow-up was ten years. Plain radiographs were analyzed for radiolucent lines. Patients who underwent revision TKA were recorded, and the cause for revision was determined. Data from the National Joint Registry for England, Wales, Northern Island, the Isle of Man and the States of Guernsey (NJR) were compared with our series.Aims
Methods
Joint registries suggest a downward trend in the use of uncemented Total Knee Replacements (TKR) since 2003, largely related to reports of early failures of uncemented tibial and patella components. Advancements in uncemented design such as trabecular metal may improve outcomes, but there is a scarcity of high-quality data from randomised trials. 319 patients <75 years of age were randomised to either cemented or
The use of high tibial osteotomy (HTO) to delay total knee arthroplasty (TKA) in young patients with osteoarthritis (OA) and constitutional deformity remains debated. The aim of this study was to compare the long-term outcomes of TKA after HTO compared to TKA without HTO, using the time from the index OA surgery as reference (HTO for the study group, TKA for the control group). This was a case-control study of consecutive patients receiving a posterior-stabilized TKA for OA between 1996 and 2010 with previous HTO. A total of 73 TKAs after HTO with minimum ten years’ follow-up were included. Cases were matched with a TKA without previous HTO for age at the time of the HTO. All revisions were recorded. Kaplan-Meier survivorship analysis was performed using revision of metal component as the endpoint. The Knee Society Score, range of motion, and patient satisfaction were assessed.Aims
Methods
Thresholds of acceptable early migration of the components in total knee arthroplasty (TKA) have traditionally ignored the effects of patient and implant factors that may influence migration. The aim of this study was to determine which of these factors are associated with overall longitudinal migration of well-fixed tibial components following TKA. Radiostereometric analysis (RSA) data over a two-year period were available for 419 successful primary TKAs (267 cemented and 152 uncemented in 257 female and 162 male patients). Longitudinal analysis of data using marginal models was performed to examine the associations of patient factors (age, sex, BMI, smoking status) and implant factors (cemented or uncemented, the size of the implant) with maximum total point motion (MTPM) migration. Analyses were also performed on subgroups based on sex and fixation.Aims
Methods
For many designs of total knee arthroplasty (TKA) it remains unclear whether cemented or uncemented fixation provides optimal long-term survival. The main limitation in most studies is a retrospective or non-comparative study design. The same is true for comparative trials looking only at the survival rate as extensive sample sizes are needed to detect true differences in fixation and durability. Studies using radiostereometric analysis (RSA) techniques have shown to be highly predictive in detecting late occurring aseptic loosening at an early stage. To investigate the difference in predicted long-term survival between cemented, uncemented, and hybrid fixation of TKA, we performed a randomized controlled trial using RSA. A total of 105 patients were randomized into three groups (cemented, uncemented, and hybrid fixation of the ACS Mobile Bearing (ACS MB) knee system, implantcast). RSA examinations were performed on the first day after surgery and at scheduled follow-up visits at three months, six months, one year, and two years postoperatively. Patient-reported outcome measures (PROMs) were obtained preoperatively and after two years follow-up. Patients and follow-up investigators were blinded for the result of randomization.Aims
Methods
Introduction. The ideal type of total knee arthroplasty (TKA) prosthesis remains a debatable topic with many different options available.
Total knee arthroplasty is an established treatment for knee osteoarthritis with excellent long-term results, but there remains controversy about the role of uncemented prostheses. We present the long-term results of a randomized trial comparing an uncemented tantalum metal tibial component with a conventional cemented component of the same implant design. Patients under the age of 70 years with symptomatic osteoarthritis of the knee were randomized to receive either an uncemented tantalum metal tibial monoblock component or a standard cemented modular component. The mean age at time of recruitment to the study was 63 years (50 to 70), 46 (51.1%) knees were in male patients, and the mean body mass index was 30.4 kg/m2 (21 to 36). The same cruciate retaining total knee system was used in both groups. All patients received an uncemented femoral component and no patients had their patella resurfaced. Patient outcomes were assessed preoperatively and postoperatively using the modified Oxford Knee Score, Knee Society Score, and 12-Item Short-Form Health Survey questionnaire (SF-12) score. Radiographs were analyzed using the American Knee Society Radiograph Evaluation score. Operative complications, reoperations, or revision surgery were recorded. A total of 90 knees were randomized and at last review 77 knees were assessed. In all, 11 patients had died and two were lost to follow-up.Aims
Methods
Introduction. A total knee arthroplasty (TKA) is the standard of care treatment for end-stage osteoarthritis (OA) of the knee. Over the last decade, we have observed a change in TKA patient population to include younger patients. This cohort tends to be more active and thus places more stress on the implanted prothesis. Bone cement has historically been used to establish fixation between the implant and host bone, resulting in two interfaces where loosening may occur. Uncemented fixation methods provide a promising alternative to cemented fixation. While vulnerable during the early post-operative period, cementless implants may be better suited to long-term stability in younger patient cohorts. It is currently unknown whether the surgical technique used to implant the cementless prostheses impacts the longevity of the implant. Two different surgical techniques are commonly used by surgeons and may result in different load distribution across the joint, which will affect bone ingrowth. The overall objective of the study is to assess implant migration and in vivo kinematics following cementless TKA. Methods. Thirty-nine patients undergoing a primary unilateral TKA as a result of OA were recruited prior to surgery and randomized to a surgical technique based on surgeon referral. In the gap balancing surgical technique (GB) soft tissues releases are made to restore neutral limb alignment followed by bone cuts (resection) to balance the joint space in flexion and extension. In the measured resection surgical technique (MR) bone cuts are first made based on anatomical landmarks and soft tissue releases are subsequently conducted with implant components in-situ. Patients returned 2 weeks, 6 weeks, 12 weeks, 24 weeks, and 52 weeks following surgery for radiographic evaluation. Kinematics were assessed 52 weeks post-operatively. Results. No significant difference was observed between groups in maximum total point motion (MTPM) at any time point during the first post-operative year. MTPM of both the tibial and femoral component did not significantly change between the six month and one year follow up visits for both the GB (6 mths=0.67 ±0.34mm, 1 yr=0.65 ±0.52, p=0.71) and MR (6 mths= 0.79 ±0.53mm, 1 yr= 0.82 ±0.43mm, p=0.56) cohorts. MTPM for both components over the follow up period is displayed in Figure 1. No significant difference was observed in contact location or pattern on the medial condyle during deep flexion (Figure 2A). A significant difference (p=0.01) was observed, however, between surgical techniques in the lateral contact location at full extension (Figure 2B). No significant difference was observed in the magnitude of AP excursion for both the medial and lateral condyles within and between groups. Conclusion. Surgical technique did not impact the MTPM of an
The aim of this study was to investigate the incidence of knee arthroplasty and arthroscopy following patellar fractures, and to compare this with an age- and gender-matched group without a prior patellar fracture. A national matched cohort study based on the Danish National Patient Register including all citizens of Denmark (approximately 5.3 million) was undertaken. A total of 6096 patients who sustained a patellar fracture in Denmark between 1 January 1996 and 31 December 2000 were included. The median age of these patients was 50.6 years (interquartile range (IQR) 28.5 to 68.9); 49.1% were women. Patients were followed-up until 31 December 2015, with regard to treatment with knee arthroplasty and/or knee arthroscopy.Aims
Patients and Methods
Introduction. Uncemented highly porous titanium implants have been shown to promote osseointegration, and may result in a durable construct for total knee arthroplasty (TKA). Given the mixed results of
Introduction. Cementless total knees were historically associated with early failure. These failures, likely associated with implant design, made cemented total knee arthroplasty (TKA) the “gold standard”. Manufacturers have introduced newer uncemented technologies that provide good initial stability and utilize a highly-porous substrates for bony in-growth. Outcome data on these implants has been limited. In addition, these implants typically have a price premium which makes them difficult to use in the setting of cost containment and in at risk 90-day bundles. Our purpose was to compare 90-day outcomes of a new uncemented implant with those of a comparable cemented implant from the same manufacturer. We hypothesized that the implants would have equivalent 90-day clinical and economic outcomes. Methods. Ninety-day clinical and economic outcomes for 252 patients with prospectively collected data from the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) database were reviewed. Ninety-day outcomes were compared between uncemented knees and an age-matched group of cemented knees (Triathlon cemented vs uncemented Triathalon-tritanium, Stryker Orthopedics, Mahwah, NJ, USA). Both cruciate retaining and posterior stabilized designs were included. MARCQI data: demographics, co-morbidities, length of stay, complications, emergency department visits, discharge disposition, and readmissions were reviewed. Financial data provided by the hospital's finance department was used for economic comparisons. Fischer's test was done to assess categorical data and a student's t-test was used to compare numerical data. Results. Uncemented knees had shorter length of stay (1.58 vs. 1.87, p<0.0001), were more frequently discharged home (90.48% vs. 68.75%; p<0.0001) and used less home care or extended care facilities (6.35% vs. 19.14%, p<0.0001; 2.78% vs. 11.72%, p=0.0001). More uncemented knees had “no complications”. Moreover, there were no reoperations in uncemented knees, compared to 19 reoperations in cemented knees most being manipulations (14 vs. 0, p=0.0028). Uncemented knees scored better than age matched counterparts Knee Injury and Osteoarthritis Outcomes Score (63.69 vs. 47.10, n=85 and 43, p<0.0001), and Patient Reported Outcomes Measurement Information System T-physical and T-mental (44.12 vs. 39.45, n=95 and 59, p<0.0001; 51.84 vs 47.82, n=97 and 59, p=0.0018). Cemented cases were more expensive overall, the surgical costs were higher ($6806.43 vs. $5710.78 p<0.01) and the total hospital costs were higher ($8347.65 vs. $7016.11 p<0.01). The 90-day readmission and hospital outpatient costs were not significantly different between the designs. Conclusion. The use of a modern
The primary stability of an
Total knee arthroplasty (TKA) is a cost effective
and extremely successful operation. As longevity increases, the demand
for primary TKA will continue to rise. The success and survivorship
of TKAs are dependent on the demographics of the patient, surgical
technique and implant-related factors. Currently the risk of failure of a TKA requiring revision surgery
ten years post-operatively is 5%. The most common indications for revision include aseptic loosening
(29.8%), infection (14.8%), and pain (9.5%). Revision surgery poses
considerable clinical burdens on patients and financial burdens
on healthcare systems. We present a current concepts review on the epidemiology of failed
TKAs using data from worldwide National Joint Registries. Cite this article:
Many aspects of total knee arthroplasty have
changed since its inception. Modern prosthetic design, better fixation techniques,
improved polyethylene wear characteristics and rehabilitation, have
all contributed to a large change in revision rates. Arthroplasty
patients now expect longevity of their prostheses and demand functional
improvement to match. This has led to a re-examination of the long-held
belief that mechanical alignment is instrumental to a successful
outcome and a focus on restoring healthy joint kinematics. A combination
of kinematic restoration and uncemented, adaptable fixation may
hold the key to future advances. Cite this article:
Summary. The 80% porous structure of trabecular metal allows for bone ingrowth in more than 90% of the available surface. The Nexgen LPS Uncemented Knee using a trabecular metal tibial component has performed well at minimum of 5 years’ follow-up. Introduction. Total Knee Arthroplasty prostheses most frequently used in today's practice have cemented components. These have shown excellent clinical results. The fixation can however weaken with time, and cement debris within the articulation can lead to accelerated wear. Cementless implants are less commonly used, but some have also shown good long-term clinical results. The potential advantages of cementless implants are retention of bone stock, less chance of third-body wear due to the absence of cement, shorter operative time, and easier treatment of periprosthetic fractures. The posterior stabilised knee replacement has been said to increase tangential shear stresses on the tibial component and increases contact stresses on the cam and post mechanism hence the great debate of cruciate retaining or cruciate sacrificing implants. Objectives. We report the results of a prospective cohort of consecutive primary total knee arthroplasties using an uncemented posterior stabilised prosthesis using a trabecular metal (tantalum) tibial component at a minimum 5-year follow-up. Methods. Prospective 5 year follow-up of patients undergone an
This is the second of a series of reviews of registries. This review looks specifically at worldwide registry data that have been collected on knee arthroplasty, what we have learned from their reports, and what the limitations are as to what we currently know.
Mortality rates reported by the National Joint Registry for England
and Wales (NJR) were higher following cemented total knee replacement
(TKR) compared with uncemented procedures. The aim of this study
is to examine and compare the effects of cemented and uncemented
TKR on the activation of selected markers of inflammation, endothelium,
and coagulation, and on the activation of selected cytokines involved
in the various aspects of the systemic response following surgery. This was a single centre, prospective, case-control study. Following
enrolment, blood samples were taken pre-operatively, and further
samples were collected at day one and day seven post-operatively.
One patient in the cemented group developed a deep-vein thrombosis
confirmed on ultrasonography and was excluded, leaving 19 patients
in this cohort (mean age 67.4, (Objective
Methods
Total knee replacement (TKR) is an established treatment for end stage joint disease of the knee. Trabecular metal is one of the design experiments seeking to improve the bone-implant interface and wear patterns in order to increase the longevity of primary joint replacements and reduce the revision burden. Uncemented implants retain bone stock, reduce third body wear, and require a shorter operative time. Although only 4% of knee replacements currently being implanted are uncemented TKRs, there has been considerable recent interest in uncemented designs with a hope of improving the survival time of primary implants. National Joint Registry data has been less favourable of uncemented designs thus far. We report our experience with these comparative implants and present our functional and radiological mid-term results. Trabecular metal is made of tantalum. It has an interconnecting 3-dimensional lattice structure which is 80% porous. It closely resembles the microstructural architecture of cancellous bone. Bone grows into the porous structure creating a strong bond between bone and implant. In this design, the tibial pegs are seated in a peripheral position, in denser cancellous bone when compared with a central peg. Tantalum offers an appropriate modulus of elasticity, reducing the likelihood of component lift-off and stress shielding. Over a 4.5 year period, between April 2007 and December 2011, 132 knees in 127 patients with a diagnosis of end stage osteoarthritis, underwent TKR at a single hospital (CMH), performed by a single surgeon (JH). All surgeries were performed with a thigh tourniquet, medial parapatellar approach, antibiotic and VTE prophylaxis, patellar resurfacing, and rapid recovery rehabilitation. 86 cemented TKRs in 78 patients (mean age 76 years), and 66 uncemented TKRs in 49 patients (mean age 68 years). All components were standard NexGen (Zimmer) implants. Follow-up was a mean of 40 months (range 6–87 months). We analysed the patient postoperative routine standing and recumbent anterior-posterior and lateral radiographs using the knee society TKA scoring system. All linear measurements were made using a PACS viewing system and analysed by 2 of the authors independently. There was no significant radiological lucent lines, and no single KSS > 4. Patients completed Oxford Knee Scores and Knee Society Scoring questionnaires to evaluate their functional outcomes. The mean OKS was 41, and KSS 89. In this period there were revisions in 3 cemented prostheses and 2 uncemented prostheses. 2 revisions were for infection, 2 for peri-prosthetic fracture following trauma, and 1 for unexplained pain. The