Advertisement for orthosearch.org.uk
Results 1 - 20 of 7352
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 12 - 12
22 Nov 2024
Wang L Trampuz A Zhang X
Full Access

Aim. Treatment of prosthetic joint infection (PJI) by systemic administration of high doses of long-term antibiotics often proves ineffective, causing severe side effects. Thus, we presented the phage Sb-1, which coding extracellular polymeric substances (EPS) degradation depolymerases, conjugated with rifampicin-loaded liposomes (Lip-RIF@Phage) by bio-orthogonal functionalization strategy to target biofilm (Figure1). Method. Methicillin-resistant Staphylococcus aureus (MRSA) biofilm was grown on porous glass beads for 24 h in vitro. After the biofilm formation, beads were exposed to 0.9% saline, then sonication. Quantitative and qualitative biofilm analyses were performed by colony counting, scanning electron microscopy and isothermal microcalorimetry. A rat model of total knee arthroplasty infected with the bioluminescent MRSA strain was developed as the PJI model to evaluate the efficacy of Lip-RIF@Phage anti-biofilm therapy in vivo, then the creatinine, alanine transaminase, and aspartate transaminase values were evaluated throughout the entire treatment process. Results. After treatment with Lip-RIF@Phage, no bacterial colonies were observed, consistent with findings from scanning electron microscopy. Similarly, isothermal microcalorimetry revealed no detectable heat following Lip-RIF@Phage treatment, aligning with these observations. In vivo experiments demonstrated a significant reduction in biofilm cell load compared to all other tested conditions, with no evidence of systemic toxicity on renal and liver functions attributed to Lip-RIF@Phage. Conclusions. The innovative depolymerase-phagobot nanosystem (Lip-RIF@Phage) exhibits remarkable efficacy in completely eliminating biofilm cells in vitro. It serves as an excellent carrier for antibiotic delivery, enhancing antibiotic penetration through biofilms and improving biofilm eradication efficacy. Furthermore, it enables personalized treatment strategies against biofilm-associated multidrug-resistant (MDR) infections by maximizing the effectiveness of any remaining sensitive antibiotics. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 13 - 13
22 Nov 2024
McNally M Dietz M Piuzzi N Chen A Parvizi J Stolarski E Pelt C Rodriguez-Quintana D Trautner B Dobbins D
Full Access

Aim. Antimicrobial peptides occur naturally in our intrinsic immune system. PLG0206 is a novel, engineered, 24-amino acid peptide which has broad-spectrum antimicrobial activity, including in biofilm and against multi-drug resistant pathogens (1,2). This is the first clinical study to evaluate the safety and tolerability of PLG0206 when administered via an irrigation solution in patients with periprosthetic joint infections (PJI) following total knee arthroplasty (TKA) during debridement, antibiotics, and implant retention (DAIR). Secondary objectives were to evaluate pharmacokinetics (PK), biomarkers and initial clinical efficacy at one year post-DAIR procedure. Method. This prospective, multicenter, open-label, interventional study assessed two dose levels of PLG0206. Fourteen patients underwent revision for PJI after TKA. At the end of debridement, they received a single intra-articular irrigation of PLG0206 into the wound cavity lasting 15 minutes at concentrations of 3 mg/mL (n=7) or 10 mg/mL (n=7). Patients received post-operative care and intravenous/oral antimicrobial therapy as per their institutional guidelines. Patients were monitored for safety and signs of relapse or persistent infection for 12 months post study drug administration and PK and blood biomarkers were assessed. Results. All patients completed their final study assessment at Day 365. Over the 1-year follow-up, only one recurrence (7%) was noted at Day 169 in the low-dose cohort. Following dosing, nine patients (64.3%) had limited systemic exposure; maximum plasma concentration occurred 1-hour post-administration and declined rapidly to undetectable levels by 24 hours following treatment in all patients. The incidence of drug related treatment-emergent adverse events (TEAEs) was low. Two patients, both in the higher dose cohort, experienced a transient drug related TEAE; one of hypertransaminasaemia and one of neuralgia. Both events were moderate in severity and resolved within two weeks of onset. Conclusions. A single 15-minute irrigation of PLG0206 into the wound cavity of patients undergoing a DAIR procedure for PJI following TKA, is safe and well tolerated by patients. This new antimicrobial peptide offers a promising therapeutic option in musculoskeletal infection. The initial clinical efficacy is encouraging but now needs to be investigated in a much larger clinical trial


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 17 - 17
22 Nov 2024
Pedemonte G Reynaga E López V de los Rios JD Molinos S Larraza AV Hermoso JAH
Full Access

Aim. Haematogenous prosthetic joint infections account for 20-35% of total prosthetic infections. Debridement, antibiotics and implant retention (DAIR) is a well-accepted treatment for these infections and probably the most desired by surgeons, since it tries to maintain a functional and stable implant. However, the risk of DAIR failure is not negligible and some risk factors have been described, and also, different scores, such as CRIME80. Nonetheless, less is known about the impact of positive blood cultures may have on DAIR treatment. The aim of our study is to analyze whether the presence of a positive culture is a risk factor for DAIR failure. Method. A retrospective cohort study of 50 late acute haematogenous TKA infections was performed from 2015 to 2023. DAIR failure was defined as the need of a subsequent intervention either a new DAIR or a revision surgery. So, patients were divided into two groups depending on the surgical outcome: successful (SG) vs failure (FG). Demographic variables including age, gender, affected side and body mass index were collected. Patient's comorbidities were also collected including chronic obstructive pulmonary disease (COPD), diabetes, rheumatoid arthritis (RA), cirrhosis and chronic renal failure, etc. Other variables, such as ones included in CRIME80 (C-reactive protein (CRP) >150mg/dl and polyethylene exchange), were also collected. Results. 30 patients had a successful DAIR outcome (60%). Age and sex do not act as risk factors [OR 0.7 (0.2-2.6) and OR 0.4 (0.1-1.3)]. Neither do COPD [OR 3.3 (0.5-2.0), p=0.2]; RA [OR 0.8 (0.2-3.1), p=0.7]; CRP value [3.2 (0.9-11.2), p=0.06]; and polyethylene exchange [OR 0.4 (0.1-2.5), p= 0.3]. Thirty-five blood cultures (70%) were obtained before surgery (20 SG and 15 FG). Nine of the obtained blood cultures were positive (25.7%), being 7 from FG (46.7%) [OR 7.6 (1.3-4.8), p=0.02]. A logistic regression was performed where positive blood cultures were the only significant variable to predict DAIR failure (OR 12, 95% CI 1.1−18, p=0.049), after adjusting for all CRIME80 variables. Skin and soft tissue origin was described in 5 of the nine positive blood cultures (55.6%). Cardiovascular system was the second most common spread (22.2%), and then followed by urogenital and digestive tract. The most common microorganism in FG was Staphylococcus aureus (57.1%) [OR 6.4 (0.2-18.0), p=0.2]. Conclusions. Positive blood cultures may be another risk factor for DAIR failure. This can be important in diagnosis and it may be taken into account in antibiotic and surgical treatment strategies


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 46 - 46
22 Nov 2024
Mozella A Leal AC Cobra H Costa G
Full Access

Aim. Evaluate the metabolites composition of the synovial fluid from patients with PJI or aseptic failure of total knee arthroplasties. Method. The synovial fluids from 21 patients scheduled for revision total knee arthroplasty (11 with the diagnosis of PJI and 10 with aseptic failures) were analyzed using 1D 1H NMR spectroscopy. Univariate and multivariate statistical analyses were used to identify metabolites that were differentially abundant between those groups. Results. A total of 28 metabolites were identified and five of them found to be differentially abundant between infected and non-infected synovial fluids. Lactate, acetate and 3-hydroxybutyrate were found to be in a higher concentration, and glucose and creatine were found reduced in the synovial fluid from PJI patients. Conclusions. Synovial fluid from patients with PJI exhibit a distinct metabolic profile, possibly reflecting metabolic adaptation that occurs in the infected periprosthetic microenvironment. Further research and studies are warranted to gain a broader insight into the metabolic pathways engaged by both pathogen and immune cells in the context of a PJI


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 43 - 43
22 Nov 2024
Bekkers W Zwart V Swietoslawki A Oost IK Nijs A Emmen J Van Geenen R
Full Access

Aim. Periprosthetic joint infection (PJI) is one of the main reasons for revision surgery after primary unicompartmental knee arthroplasty (UKA), total knee arthroplasty (TKA) or total hip arthroplasty (THA). Currently the MSIS and EBJIS criteria sets are considered to be the gold standards in determining PJI. These criteria sets are complex and contain tests that are time-consuming and many are rather costly. Therefore, further research is indicated to find a simpler but equally reliable diagnostic test. In this study we evaluated the additional value of calprotectine measurement in synovial fluid in patients undergoing hip and knee (revision) arthroplasty following routine work-up. Method. In a retrospective cohort study, we analyzed 182 synovial fluid samples from 143 patients with suspected PJI after UKA, TKA, THA or revision arthroplasty. Twenty-six of those cases were classified as PJI according to the MSIS and EBJIS criteria. Subsequently, synovial calprotectin was determined, using a lateral flow assay and two cut-off thresholds of ≥14 mg/L and ≥50 mg/L. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of synovial calprotectin was determined. Results. When applying the MSIS and EBJIS criteria and a calprotectin level ≥14 mg/L, synovial calprotectin revealed an area under the curve of 0.96 (95% CI 0.90-1.00), with 92.3% sensitivity and 100% specificity. The PPV and NPV were 100% and 92.9% respectively. When applying the MSIS and EBJIS criteria and a calprotectin level ≥ 50 mg/L, synovial calprotectin revealed an area under the curve of 0.94 (95% CI 0.87-1.00), with 88.5% sensitivity and 100% specificity. The PPV and NPV were 100% and 89.7% respectively. Conclusions. The value of calprotectin in synovial fluid gives valuable information with a single test result, resulting in high predictive value in the diagnosis of PJI after hip or knee arthroplasty and should seriously be considered as part of PJI diagnostics in an outpatient clinical setting. The high specificity can help rule in patients that are suspected of PJI. Therefor this test can be helpful in a preop diagnostic work-up to avoid unnecessary revisions in patients with well-placed and well-fixed arthroplasties with a suspected PJI. These conclusions are independent of which criteria set was used as a gold standard


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 32 - 32
22 Nov 2024
Granata V Strina D Possetti V Leone R Valentino S Chiappetta K Bottazzi B Mantovani A Loppini M Asselta R Sobacchi C Inforzato A
Full Access

Aim. Periprosthetic joint infection (PJI) is one of the most serious and frequent complications in prosthetic surgery. Despite significant improvements in the criteria for diagnosis of PJI, the diagnostic workflow remains complex and, sometimes, inconclusive. Host immune factors hold great potential as diagnostic biomarkers in bone and joint infections. We have recently reported that the synovial concentration of the humoral pattern recognition molecule long pentraxin 3 (PTX3) is a sensitive and specific marker of PJI in total hip and knee arthroplasty patients (THA and TKA) undergoing revision surgery [1]. However, the contribution to risk and diagnosis of PJI of the genetic variation in PTX3 and inflammatory genes that are known to affect its expression (IL-1b, IL-6, IL-10, and IL-17A) has not been addressed. Therefore, we assessed these relationships in a cohort of THA and TKA patients who underwent prosthesis revision by focusing on a panel of single nucleotide polymorphisms (SNPs) in the PTX3, IL-1β, IL-6, IL-10 and IL-17A genes. Method. A case-control retrospective study was conducted on an historic cohort of patients that received THA or TKA revision and were diagnosed with PJI (cases) or aseptic complications (controls) [1]. Samples of saliva were collected from 93 subjects and used for extraction of genomic DNA to perform genotyping of the PTX3, IL-1β, IL-6, IL-10 and IL-17A polymorphisms. Moreover, whenever available, samples of synovial fluid and plasma [1] were used to measure the concentration of the IL-1β, IL-10, and IL-6 proteins by immunoassay. Uni-and multivariate analyses were performed to evaluate the relationships between genetic, biochemical, and clinical variables. Results. The rs3024491 (IL-10) and rs2853550 (IL-1b) SNPs were found to be strongly associated with the risk of PJI. The synovial levels of PTX3, IL-1β, IL-10, and IL-6 were higher in cases than in controls, and a clear correlation emerged between the synovial concentration of PTX3 and IL-1b in cases only. Also, we identified a causal relationship between rs2853550, synovial concentration of IL-1b and that of PTX3 (that is induced by IL-1b). Conclusions. Our findings suggest that SNPs in the IL-10 and IL-1b genes could be used for early identification of THA and TKA patients with high risk of PJI. It is therefore conceivable that integrating genetic data into current diagnostic criteria would improve diagnosis of PJI


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 71 - 71
22 Nov 2024
Cobra H Mozella A Leal AC
Full Access

Aim. Periprosthetic joint infection (PJI) is one of the most frequent and devastating complications of total knee arthroplasty (TKA). Accurate diagnosis and proper treatment are essential to prevent functional loss and progression to systemic infection. However, the correct diagnosis of PJI is still a challenge since there is no accurate diagnostic method and the existing diagnostic criteria are based on serological, histological and microbiological tests that are imprecise and time-consuming. Recently, it was demonstrated that cell-free DNA is increased in the synovial fluid of patients with PJI. Therefore, this study aims to evaluate a new point-of-care methodology for quantifying free DNA in synovial fluid. Method. A prospective study was carried out with patients undergoing TKA revision surgery, from whom it was possible to collect synovial fluid (SF) during the surgical procedure. Cell-free DNA quantification was performed directly from the SF, using a portable fluorimeter. Sensitivity, specificity and receiver operating characteristic (ROC) curve were calculated. Results. Fifty-four patients were included in the study, of which 25 were diagnosed with PJI. Cell-free DNA levels measured immediately after collection were increased in the synovial fluid of patients with PJI (26.3 ± 14.8) in comparison with the uninfected group (4.6 ng/ml ± 3.8, p< 0.0001). The area under the receiver operating characteristic curve (AUC ROC) was 0.981 (95% CI 0.914 to 0.999). Conclusions. From the results presented, we can conclude that the quantification of free DNA with a portable fluorimeter proved to be a test with high sensitivity and specificity for the diagnosis of PJI


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 85 - 85
22 Nov 2024
Sayol RR Lopez XP Regulez BV Bueno JC Garcia JCM Álvarez JM Fernández JS Gonzalez SG
Full Access

Aim. There is controversy regarding the use of Antibiotic-loaded cement (ALBC) as compared to non-antibiotic-loaded cement (NALBC) to reduce the overall infection rate without affecting implant survival or adding additional risks on fixation for primary total knee arthroplasty (TKA). Method. To conduct the analysis, we utilized the Catalan Arthroplasty Registry (RACat) for the TKAs implanted between 2005 and 2017. The primary variable recorded was the use of cement with or without antibiotics. Other recorded variables included were age, sex, diabetes mellitus, obesity, Charlson index and type of hospital. We analyzed the effect of ALBC vs. NALBC in reducing the risk of prosthetic infection at 3, 6, 12, and 24 months as well as prosthetic survival due to mechanical causes at 1, 5, and 10 years. Univariate and multivariable analyses of risk factors were conducted. Thereby, an interactive predictive model that determines the risk of prosthetic infection based on each patient's characteristics was created. Results. A total of 28,287 TKAs from the RACat were analyzed. In that total, there were 19,788 NALBC and 8,499 ALBC. The infection rates for TKAs with NALBC vs. those with ALBC at 3, 6, 12, and 24 months were respectively: 1.69% vs. 1.39% (p=0.132); 1.81% vs. 1.56% (p=0.147); 2.14% vs. 1.73% (p=0.030); 2.51% vs. 1.86% (p=0.001). A statistically significant reduction in periprosthetic infection rate was observed in the ALBC group at 12 and 24 months. No differences were observed between the two groups in terms of prosthetic mechanical survival. Being younger, male and having had previous knee surgery or having a high comorbidity index all led to a higher risk of prosthetic revision due to infection. Conclusions. The use of ALBC as a fixation method for TKA leads to a reduction in the risk of prosthetic infection without altering the mechanical survival of the implant. The creation of a predictive model helps determine the individualized risk of prosthetic infection based on the patient's characteristics


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 61 - 61
22 Nov 2024
Giebel G Niemann M Pidgaiska O Trampuz A Perka C Meller S
Full Access

Aim. As the number of performed total hip arthroplasties (THA) and total knee arthroplasties (TKA) has increased over the years, revision surgeries are expected to increase as well. Revision surgeries are associated with a longer operating room time, prolonged length of stay (LOS), and more frequent complications. Postoperative hematomas are a major reason for wound healing disturbances and periprosthetic joint infections (PJI). We aimed to systematically assess the use and safety of a microporous polysaccharide hemosphere (MPH) in revision THA and TKA. We focused on the risk reduction of further revision surgeries in case of wound healing disorders and hematoma, transfusion of packed red blood cells (PRBC), loss of hemoglobin (hb) and mean LOS following the use of MPH. Method. Our prospective study includes 89 patients who underwent revision surgery after THA and TKA with application of MPH and were compared to 102 patients who did not receive MPH and underwent revision surgery after THA and TKA. Five grams of MPH. 1. were applied periarticular before fascia closure and to the subcutaneous soft tissue. The follow-up was conducted in daily clinical visits during the inpatient stay and three months postoperatively in our outpatient clinic. Repeated revision surgery was performed in case of prolonged secretion (>10 days) or clinical suspicion of infection. After matching the cohorts the outcomes were statistically analyzed using paired methods. Results. A significantly lower odds ratio for repeat revisions was found for the MPH cohort (OR=0.312; 95%-CI 0.090, 0.893; p=0.027). Differences between pre- and postoperative hb levels, LOS and transfusions of PRBC did not reach significance. No intra- or postoperative complications to MPH occurred. Moreover, no infection relapse occurred after applying MPH. Conclusions. Routine use of MPH in revision arthroplasty management after TKA and THA appears to be safe and an effective way to support hemostasis, with no observed adverse events related to MPH use. There were noticeably less hematomas and revision surgeries in the MPH group. 1. Arista BD, Franklin Lakes, NJ, USA


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 31 - 31
22 Nov 2024
Yoon S Jutte P Soriano A Sousa R Zijlstra W Wouthuyzen-Bakker M
Full Access

Aim. This study aimed to externally validate promising preoperative PJI prediction models in a recent, multinational European cohort. Method. Three preoperative PJI prediction models (by Tan et al., Del Toro et al., and Bülow et al.) which previously demonstrated high levels of accuracy were selected for validation. A multicenter retrospective observational analysis was performed of patients undergoing total hip arthroplasty (THA) and total knee arthroplasty (TKA) between January 2020 and December 2021 and treated at centers in the Netherlands, Portugal, and Spain. Patient characteristics were compared between our cohort and those used to develop the prediction models. Model performance was assessed through discrimination and calibration. Results. A total of 2684 patients were included of whom 60 developed a PJI (2.2%). Our patient cohort differed from the models’ original cohorts in terms of demographic variables, procedural variables, and the prevalence of comorbidities. The c-statistics for the Tan, Del Toro, and Bülow models were 0.72, 0.69, and 0.72 respectively. Calibration was reasonable, but precise percentage estimates for PJI risk were most accurate for predicted risks up to 3-4%; the Tan model overestimated risks above 4%, while the Del Toro model underestimated risks above 3%. Conclusions. In this multinational cohort study, the Tan, Del Toro, and Bülow PJI prediction models were found to be externally valid for classifying high risk patients for developing a PJI. These models hold promise for clinical application to enhance preoperative patient counseling and targeted prevention strategies. Keywords. Periprosthetic Joint Infection (PJI), High Risk Groups, Prediction Models, Validation, Infection Prevention


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 25 - 25
14 Nov 2024
Taylan O Louwagie T Bialy M Peersman G Scheys L
Full Access

Introduction. This study aimed to evaluate the effectiveness of a novel intraoperative navigation platform for total knee arthroplasty (TKA) in restoring native knee joint kinematics and strains in the medial collateral ligament (MCL) and lateral collateral ligament (LCL) during squatting motions. Method. Six cadaver lower limbs underwent computed tomography scans to design patient-specific guides. Using these scans, bony landmarks and virtual single-line collateral ligaments were identified to provide intraoperative real-time feedback, aided in bone resection, implant alignment, tibiofemoral kinematics, and collateral ligament elongations, using the navigation platform. The specimens were subjected to squatting (35°-100°) motions on a physiological ex vivo knee simulator, maintaining a constant 110N vertical ankle load regulated by active quadriceps and bilateral hamstring actuators. Subsequently, each knee underwent a medially-stabilized TKA using the mechanical alignment technique, followed by a retest under the same conditions used preoperatively. Using a dedicated wand, MCL and LCL insertions—anterior, middle, and posterior bundles—were identified in relation to bone-pin markers. The knee kinematics and collateral ligament strains were analyzed from 3D marker trajectories captured by a six-camera optical system. Result. Both native and TKA conditions demonstrated similar patterns in tibial valgus orientation (Root Mean Square Error (RMSE=1.7°), patellar flexion (RMSE=1.2°), abduction (RMSE=0.5°), and rotation (RMSE=0.4°) during squatting (p>0.13). However, a significant difference was found in tibial internal rotation between 35° and 61° (p<0.045, RMSE=3.3°). MCL strains in anterior (RMSE=1.5%), middle (RMSE=0.8%), and posterior (RMSE=0.8%) bundles closely matched in both conditions, showing no statistical differences (p>0.05). Conversely, LCL strain across all bundles (RMSE<4.6%) exhibited significant differences from mid to deep flexion (p<0.048). Conclusion. The novel intraoperative navigation platform not only aims to achieve planned knee alignment but also assists in restoring native knee kinematics and collateral ligament behavior through real-time feedback. Acknowledgment. This study was funded by Medacta International (Castel San Pietro, Switzerland)


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 75 - 75
14 Nov 2024
Khalid T Shlomo YB Bertram W Culliford L enderson E Jepson M Johnson E Palmer S Whitehouse M Wylde V
Full Access

Introduction. Approximately 20-25% of patients having joint replacement in the UK have moderate-severe frailty. Frailty is associated with poorer outcomes after joint replacement. Targeting frailty pre-operatively with exercise and protein supplementation could improve post-operative outcomes. Prior to conducting a randomised controlled trial (RCT), a feasibility study was necessary to inform trial design and delivery. Method. We conducted a randomised feasibility study with embedded qualitative work. Patients aged ≥65 years, frail and undergoing THR or TKR were recruited from three UK hospitals. Participants were randomly allocated on a 1:1 ratio to the intervention or usual care group. The intervention group had a 1:1 appointment with a physiotherapist and were provided with a home-based, tailored daily exercise programme and a daily protein supplement for 12 weeks before their operation, supported by six telephone calls from a physiotherapist. Questionnaires were administered at baseline and 12 weeks after randomisation. Interviews were conducted with 19 patients. Feasibility outcomes were eligibility and recruitment rates, intervention adherence, and acceptability of the trial and the intervention. Result. 411 patients were sent a screening pack. Of the 168 patients who returned a screening questionnaire, 79 were eligible and consented to participate, and 64 were randomised. Of the 33 participants randomised to the intervention, 26 attended the intervention appointment. Eighteen participants (69%) received all six intervention follow-up telephone calls. Nineteen participants completed an intervention adherence log; 13 (68%) adhered to the exercise programme and 11 (58%) adhered to the protein supplementation. The overall retention rate was 86% at 12 weeks. The 12-week follow-up questionnaire was returned by 84% of participants who were sent a questionnaire. Interviews found that the trial and intervention were generally acceptable, but areas of potential improvements were identified. Conclusion. This study demonstrated that a larger study is possible and has identified improvements to optimise the design of a RCT


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 5 - 5
14 Nov 2024
Panagiota Glynou S Musbahi O Cobb J
Full Access

Introduction. Knee arthroplasty (KA), encompassing Total Knee Replacement (TKR) and Unicompartmental Knee Replacement (UKR), is one of the most common orthopedic procedures, aimed at alleviating severe knee arthritis. Postoperative KA management, especially radiographic imaging, remains a substantial financial burden and lacks standardised protocols for its clinical utility during follow-up. Method. In this retrospective multicentre cohort study, data were analysed from January 2014 to March 2020 for adult patients undergoing primary KA at Imperial NHS Trust. Patients were followed over a five-year period. Four machine learning models were developed to evaluate if post-operative X-ray frequency can predict revision surgery. The best-performing model was used to assess the risk of revision surgery associated with different number of X-rays. Result. The study assessed 289 knees with a 2.4% revision rate. The revision group had more X-rays on average than the primary group. The best performing model was Logistic Regression (LR), which indicated that each additional X-ray raised the revision risk by 52% (p<0.001). Notably, having four or more X-rays was linked to a three-fold increase in risk of revision (OR=3.02; p<0.001). Our results align with the literature that immediate post-operative X-rays have limited utility, making the 2nd post-operative X-ray of highest importance in understanding the patient's trajectory. These insights can enhance management by improving risk stratification for patients at higher revision surgery risk. Despite LR being the best-performing model, it is limited by the dataset's significant class imbalance. Conclusion. X-ray frequency can independently predict revision surgery. This study provides insights that can guide surgeons in evidence-based post-operative decision-making. To use those findings and influence post-operative management, future studies should build on this predictive model by incorporating a more robust dataset, surgical indications, and X-ray findings. This will allow early identification of high-risk patients, allowing for personalised post-operative recommendations


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 24 - 24
14 Nov 2024
Petersen ET Linde KN Burvil CCH Rytter S Koppens D Dalsgaard J Hansen TB Stilling M
Full Access

Introduction. Knee osteoarthritis often causes malalignment and altering bone load. This malalignment is corrected during total knee arthroplasty surgery, balancing the ligaments. Nonetheless, preoperative gait patterns may influence postoperative prosthesis load and bone support. Thus, the purpose is to investigate the impact of preoperative gait patterns on postoperative femoral and tibial component migration in total knee arthroplasty. Method. In a prospective cohort study, 66 patients with primary knee osteoarthritis undergoing cemented Persona total knee arthroplasty were assessed. Preoperative knee kinematics was analyzed through dynamic radiostereometry and motion capture, categorizing patients into four homogeneous gait patterns. The four subgroups were labeled as the flexion group (n=20), the abduction (valgus) group (n=17), the anterior drawer group (n=10), and the tibial external rotation group (n=19). The femoral and tibial component migration was measured using static radiostereometry taken supine on the postoperative day (baseline) and 3-, 12-, and 24- months after surgery. Migration was evaluated as maximum total point motion. Result. Of the preoperatively defined four subgroups, the abduction group with a valgus-characterized gait pattern exhibited the highest migration for both the femoral (1.64 mm (CI95% 1.25; 2.03)) and tibial (1.21 mm (CI95% 0.89; 1.53)) components at 24-month follow-up. For the femoral components, the abduction group migrated 0.6 mm (CI95% 0.08; 1.12) more than the external rotation group at 24 months. For the tibial components, the abduction group migrated 0.43 mm (CI95% 0.16; 0.70) more than the external rotation group at 3 months. Furthermore, at 12- and 24-months follow-up the abduction group migrated 0.39 mm (95%CI 0.04; 0.73) and 0.45 mm (95%CI 0.01; 0.89) more than the flexion group, respectively. Conclusion. A preoperative valgus-characterized gait pattern seems to increase femoral and tibial component migration until 2 years of follow-up. This suggests that the implant fixation depends on load distributions originating from specific preoperative gait patterns


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 118 - 118
14 Nov 2024
Schlauch A Shah I Crawford B Martin A Denisov A Tamer P Farrell B
Full Access

Introduction. Distal femur fractures around a total knee arthroplasty (TKA) are a growing problem for orthopaedic surgeons. The purpose of this study was to identify risks of reoperation for nonunion following open reduction and internal fixation of TKA periprosthetic distal femur fractures (PDFF). Method. Patients with PDFF (AO 33A-C[VB1, C1, D1], Su types 1-3) managed operatively with open reduction and internal fixation (ORIF) were retrospectively reviewed. Exclusion criteria were acute management with a distal femur replacement, less than 6 months of follow-up, and lack of injury or follow-up radiographs. The primary outcome measure was reoperation to achieve bony union. Comparisons were made between cases that did and did not require a reoperation to achieve union. Univariate analysis was used to identify factors to be analyzed in multivariate analysis to determine independent risk factors for the primary outcome. Result. A total of 77 patients met inclusion criteria. Union rate was 69/77 (89.6%). There were no differences between the groups for age, sex, BMI, comorbidities, Su classification, open injury, or mechanism of injury. Multivariate analysis identified risks for nonunion including post-operative malalignment (OR 1.41; CI 1.20-1.64; p<0.001), notching pre-operatively (OR 1.22; CI 1.04-1.42; p=0.012), presence of screws through fracture line (OR 1.28; CI 1.17-1.39; p<0.001), plate length <12 holes (OR 1.16; CI 1.02-1.33; p=0.024) and screw density greater than 0.4 (OR 2.18; CI 1.25-3.78; p=0.006). Conclusion. The reoperation rate to promote union was 10.4%. The study identified post-operative malalignment, notching pre-operatively, presence of screws through fracture line, plate length <12 holes, and proximal screw density greater than 40% as independent risk factors for nonunion


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 42 - 42
14 Nov 2024
Kato K Hayashi S
Full Access

Purpose. To compare postoperative clinical outcomes between posterior cruciate ligament (PCL) retaining and resecting total knee arthroplasty (TKA) using same cruciate-substituting (CS) inserts, and to elucidate the clinical relevance of the residual PCL in cruciate-retaining TKA, considering intraoperative influence factors, such as the posterior tibial slope, posterior condylar offset, joint gap, joint balance, and joint laxity. Methods. A total of 64 consecutive knees (44 patients) were enrolled in this study and divided into following two groups: 39 knees underwent PCL-retaining TKA group (CR group), and 25 underwent PCL-resecting TKA group (CS group). Preoperative patients’ demographic data and one-year postoperative clinical outcomes including range of motion, the Knee Injury and Osteoarthritis Outcome Score (KOOS), the Japanese Orthopaedic Association (JOA) score, and Forgotten Joint Score-12 (FJS-12) were compared between two groups. Results. Regarding range of motion, the average preoperative ROM was -14.3/120.0 degrees in the CR group and improved to -2.4/118.9 degrees postoperatively. In the CS group, the average preoperative ROM was -7.5/130 degrees and changed to -2.2/122.4 degrees postoperatively. There was no significant difference in the postoperative ROM between the groups (P=0.16). The KOOS (from 47.1 to 69.5 in CR group; from 41.1 to 70.8 in CS group) and JOA scores (from 59.2 to 76.9 in CR group; from 55.6 to 80.8 in CS group) were significantly improved postoperatively in both groups (P < 0.01). However, there was no significance in these postoperative scores between two groups (P = 0.09). There was also no significance in FJS-12 between two groups (70.3 in CR group and 66.9 in CS group; P=0.53). Conclusions. Residual PCL in TKA with a CS insert would not impact one-year postoperative clinical outcomes including KOOS, JOA, and FJS-12


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 129 - 129
14 Nov 2024
Larsen JB Skou ST Laursen M Bruun NH Bandholm T Arendt-Nielsen L Madeleine P
Full Access

Introduction. There is a lack of evidence-based treatments for patients with chronic pain after total knee arthroplasty (TKA). It is well-established that knee extensor and flexor muscle strength are markedly impaired following TKA, but no studies have examined muscle strength and power in patients with chronic pain after TKA. Therefore, the aim was to investigate if neuromuscular exercises and pain neuroscience education (PNE) were superior to PNE alone for improvement of muscle strength and power in patients with chronic pain after TKA. Method. This report presents the exploratory analysis of a randomized controlled trial (NCT03886259). Participants with chronic moderate-to-severe average daily pain intensity and no signs of prosthesis failure at least one year after primary TKA were included. Participants were randomized to receive either supervised neuromuscular exercise and PNE or the same PNE sessions alone. The outcomes were changes from baseline to 12-months for peak leg extension power and maximum muscle strength, measured during maximal voluntary isometric contractions, for the knee extensors and flexors. Result. Sixty-nine participants (age 62.2±7.2, 40 females) were included. No between-group differences were observed for peak leg extension power (difference 13.6 Watts, 95% CI -22.2 to 49.3), maximum knee extensor muscle strength (difference -20.9 Newtons, 95% CI -65.8 to 24.0) or maximum knee flexor muscle strength (difference 8.6 Newtons, 95% CI -11.9 to 29.1). Peak leg extension power (26.3 Watts, 95% CI 4.3 to 48.3) and maximum knee flexor muscle strength (19.7 Newtons, 95% CI 7.6 to 31.9) improved significantly in the neuromuscular exercise and PNE group with no significant improvements observed in the PNE alone group. Conclusion. Neuromuscular exercise and PNE did not improve muscle strength and power compared to PNE alone in patients with chronic pain after TKA. Acknowledgements. This study was funded by the Danish Rheumatism Association, the Svend Andersen Foundation and Lions Club Denmark


Bone & Joint Open
Vol. 5, Issue 11 | Pages 1013 - 1019
11 Nov 2024
Clark SC Pan X Saris DBF Taunton MJ Krych AJ Hevesi M

Aims. Distal femoral osteotomies (DFOs) are commonly used for the correction of valgus deformities and lateral compartment osteoarthritis. However, the impact of a DFO on subsequent total knee arthroplasty (TKA) function remains a subject of debate. Therefore, the purpose of this study was to determine the effect of a unilateral DFO on subsequent TKA function in patients with bilateral TKAs, using the contralateral knee as a self-matched control group. Methods. The inclusion criteria consisted of patients who underwent simultaneous or staged bilateral TKA after prior unilateral DFO between 1972 and 2023. The type of osteotomy performed, osteotomy hardware fixation, implanted TKA components, and revision rates were recorded. Postoperative outcomes including the Forgotten Joint Score-12 (FJS-12), Tegner Activity Scale score, and subjective knee preference were also obtained at final follow-up. Results. A total of 21 patients underwent bilateral TKA following unilateral DFO and were followed for a mean of 31.5 years (SD 11.1; 20.2 to 74.2) after DFO. The mean time from DFO to TKA conversion was 13.1 years (SD 9.7) with 13 (61.9%) of DFO knees converting to TKA more than ten years after DFO. There was no difference in arthroplasty implant systems employed in both the DFO-TKA and TKA-only knees (p > 0.999). At final follow-up, the mean FJS-12 of the DFO-TKA knee was 62.7 (SD 36.6), while for the TKA-only knee it was 65.6 (SD 34.7) (p = 0.328). In all, 80% of patients had no subjective knee preference or preferred their DFO-TKA knee. Three DFO-TKA knees and two TKA-only knees underwent subsequent revision following index arthroplasty at a mean of 12.8 years (SD 6.9) and 8.5 years (SD 3.8), respectively (p > 0.999). Conclusion. In this self-matched study, DFOs did not affect subsequent TKA function as clinical outcomes, subjective knee preference, and revision rates were similar in both the DFO-TKA and TKA-only knees at mean 32-year follow-up. Cite this article: Bone Jt Open 2024;5(11):1013–1019


Bone & Joint Research
Vol. 13, Issue 11 | Pages 632 - 646
7 Nov 2024
Diaz Dilernia F Watson D Heinrichs DE Vasarhelyi E

Aims

The mechanism by which synovial fluid (SF) kills bacteria has not yet been elucidated, and a better understanding is needed. We sought to analyze the antimicrobial properties of exogenous copper in human SF against Staphylococcus aureus.

Methods

We performed in vitro growth and viability assays to determine the capability of S. aureus to survive in SF with the addition of 10 µM of copper. We determined the minimum bactericidal concentration of copper (MBC-Cu) and evaluated its sensitivity to killing, comparing wild type (WT) and CopAZB-deficient USA300 strains.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 992 - 998
6 Nov 2024
Wignadasan W Magan A Kayani B Fontalis A Chambers A Rajput V Haddad FS

Aims

While residual fixed flexion deformity (FFD) in unicompartmental knee arthroplasty (UKA) has been associated with worse functional outcomes, limited evidence exists regarding FFD changes. The objective of this study was to quantify FFD changes in patients with medial unicompartmental knee arthritis undergoing UKA, and investigate any correlation with clinical outcomes.

Methods

This study included 136 patients undergoing robotic arm-assisted medial UKA between January 2018 and December 2022. The study included 75 males (55.1%) and 61 (44.9%) females, with a mean age of 67.1 years (45 to 90). Patients were divided into three study groups based on the degree of preoperative FFD: ≤ 5°, 5° to ≤ 10°, and > 10°. Intraoperative optical motion capture technology was used to assess pre- and postoperative FFD. Clinical FFD was measured pre- and postoperatively at six weeks and one year following surgery. Preoperative and one-year postoperative Oxford Knee Scores (OKS) were collected.