Abstract
Aim
Periprosthetic joint infection (PJI) is one of the most frequent and devastating complications of total knee arthroplasty (TKA). Accurate diagnosis and proper treatment are essential to prevent functional loss and progression to systemic infection. However, the correct diagnosis of PJI is still a challenge since there is no accurate diagnostic method and the existing diagnostic criteria are based on serological, histological and microbiological tests that are imprecise and time-consuming. Recently, it was demonstrated that cell-free DNA is increased in the synovial fluid of patients with PJI. Therefore, this study aims to evaluate a new point-of-care methodology for quantifying free DNA in synovial fluid.
Method
A prospective study was carried out with patients undergoing TKA revision surgery, from whom it was possible to collect synovial fluid (SF) during the surgical procedure. Cell-free DNA quantification was performed directly from the SF, using a portable fluorimeter. Sensitivity, specificity and receiver operating characteristic (ROC) curve were calculated.
Results
Fifty-four patients were included in the study, of which 25 were diagnosed with PJI. Cell-free DNA levels measured immediately after collection were increased in the synovial fluid of patients with PJI (26.3 ± 14.8) in comparison with the uninfected group (4.6 ng/ml ± 3.8, p< 0.0001). The area under the receiver operating characteristic curve (AUC ROC) was 0.981 (95% CI 0.914 to 0.999).
Conclusions
From the results presented, we can conclude that the quantification of free DNA with a portable fluorimeter proved to be a test with high sensitivity and specificity for the diagnosis of PJI.