Custom-made partial pelvis replacements (PPRs) are increasingly used in the reconstruction of large acetabular defects and have mainly been designed using a triflange approach, requiring extensive soft-tissue dissection. The monoflange design, where primary intramedullary fixation within the ilium combined with a monoflange for rotational stability, was anticipated to overcome this obstacle. The aim of this study was to evaluate the design with regard to functional outcome, complications, and acetabular reconstruction. Between 2014 and 2023, 79 patients with a mean follow-up of 33 months (SD 22; 9 to 103) were included. Functional outcome was measured using the Harris Hip Score and EuroQol five-dimension questionnaire (EQ-5D). PPR revisions were defined as an endpoint, and subgroups were analyzed to determine risk factors.Aims
Methods
Anterior tibial translation (ATT) is assessed in the acutely injured knee to investigate for ligamentous injury and rotational laxity. Specifically, there is a growing recognition of the significance of anterior medial rotary laxity (AMRI) as a crucial element in assessing knee stability. Anterior cruciate ligament (ACL) injuries are often accompanied with medial collateral ligament (MCL) damage. It has been suggested that Deep MCL (dMCL) fibres are a primary restraint in rotational displacement. This research aims to quantify the difference in rotational laxity of patients with ACL and MCL injuries to deem if the Feagin-Thomas test can robustly capture metrics of AMRI. 2. AMRI was assessed using the Feagin-Thomas test in 7 isolated ACL (iACL) injured participants, 3 combined ACL and superficial fibre MCL (sMCL) injuries, 5 combined ACL and deep fibre MCL injuries, and 21 healthy controls. Displacement values were recorded using an optical motion capture (OMC) system and bespoke processing pipeline which map and model the knee's anterior displacement values relative to the medial compartment. Since absolute values (mm) of rotational laxity vary dependant on the person, values were recorded as a proportion of the rotational laxity obtained from the subject's contralateral leg. Values were compared between each patient group using an ANOVA test and Tukey's honesty significant difference post hoc test. 3.Introduction
Methods
The primary aim of this trial was to compare the subsidence of two similar hydroxyapatite-coated titanium femoral components from different manufacturers. Secondary aims were to compare rotational migration (anteversion/retroversion and varus/valgus tilt) and patient-reported outcome measures between both femoral components. Patients were randomized to receive one of the two femoral components (Avenir or Corail) during their primary total hip arthroplasty between August 2018 and September 2020. Radiostereometric analysis examinations at six, 12, and 24 months were used to assess the migration of each implanted femoral component compared to a baseline assessment. Patient-reported outcome measures were also recorded for these same timepoints. Overall, 50 patients were enrolled (62% male (n = 31), with a mean age of 65.7 years (SD 7.3), and mean BMI of 30.2 kg/m2 (SD 5.2)).Aims
Methods
Persistent medial laxity increases the risk of failure for ACL reconstruction. To address this, multiple reconstruction techniques have been created. To date, no single strand reconstruction constructs have been able to restore both valgus and rotational stability. In response to this, a novel single strand Short Isometric Construct (SIC) MCL reconstruction was developed. Eight fresh-frozen cadaveric specimens were tested in three states: 1) intact 2) after sMCL and dMCL transection, and 3) after SIC MCL reconstruction. In each state, four loading conditions were applied at varying flexion angles: 90N anterior drawer, 5Nm tibial external rotation torque, 8Nm valgus torque, and combined 90N anterior drawer plus 5Nm tibial external rotation torque.Abstract
Introduction
Methods
Historic MCL reconstruction techniques focused on the superficial MCL to restore valgus stability while overlooking tibial external rotation and the deep MCL. This study assessed the ability of a contemporary medial collateral ligament (MCL) reconstruction and a deep MCL (dMCL) reconstruction to restore rotational and valgus knee stability. Six pairs fresh-frozen cadaveric knee specimens with intact soft tissue were tested in four states: 1) intact 2) after sMCL and dMCL sectioning, 3) contemporary MCL reconstruction (LaPrade et al), and 4) dMCL reconstruction. In each state, four loading conditions were applied at varying flexion angles: 8Nm valgus torque, 5Nm tibial external rotation torque, 90N anterior drawer, and combined 90N anterior drawer plus 5Nm tibial external rotation torque.Abstract
Introduction
Methods
Vitamin E-infused highly crosslinked polyethylene (VEPE) has been introduced into total hip arthroplasty (THA) with the aim of further improving the wear characteristics of moderately and highly crosslinked polyethylenes (ModXLPE and HXLPE). There are few studies analyzing the outcomes of vitamin E-infused components in cemented arthroplasty, though early acetabular component migration has been reported. The aim of this study was to measure five-year polyethylene wear and acetabular component stability of a cemented VEPE acetabular component compared with a ModXLPE cemented acetabular component. In a prospective randomized controlled trial (RCT), we assessed polyethylene wear and acetabular component stability (primary outcome) with radiostereometric analysis (RSA) in 68 patients with reverse hybrid THA at five years follow-up. Patients were randomized to either a VEPE or a ModXLPE cemented acetabular component.Aims
Methods
The objective of this study was to investigate bone healing after
internal fixation of displaced femoral neck fractures (FNFs) with
the Dynamic Locking Blade Plate (DLBP) in a young patient population
treated by various orthopaedic (trauma) surgeons. We present a multicentre prospective case series with a follow-up
of one year. All patients aged ≤ 60 years with a displaced FNF treated
with the DLBP between 1st August 2010 and December 2014 were included.
Patients with pathological fractures, concomitant fractures of the
lower limb, symptomatic arthritis, local infection or inflammation,
inadequate local tissue coverage, or any mental or neuromuscular
disorder were excluded. Primary outcome measure was failure in fracture
healing due to nonunion, avascular necrosis, or implant failure
requiring revision surgery.Aims
Patients and Methods
Fractures of the proximal femur are a common clinical problem, and a number of orthopaedic devices are available for the treatment of such fractures. The objective of this study was to assess the rotational stability, a common failure predictor, of three different rotational control design philosophies: a screw, a helical blade and a deployable crucifix. Devices were compared in terms of the mechanical work (W) required to rotate the implant by 6° in a bone substitute material. The substitute material used was Sawbones polyurethane foam of three different densities (0.08 g/cm3, 0.16 g/cm3 and 0.24 g/cm3). Each torsion test comprised a steady ramp of 1°/minute up to an angular displacement of 10°.Objectives
Methods
Injury to the anterolateral ligament (ALL) has been reported to contribute to high-grade anterolateral laxity following anterior cruciate ligament (ACL) injury. Failure to address ALL injury has been suggested as a cause of persistent rotational laxity following ACL reconstruction. However, lateral meniscus posterior root (LMPR) tears have also has been shown to cause increased internal rotation and anterior translation of the knee. Due to the anatomic relationship of the ALL and the lateral meniscus, we hypothesise that the ALL and lateral meniscus work synergistically, and that a tear to the LMPR will have the same effect on anterolateral laxity as an ALL tear in the ACL deficient knee. Sixteen fresh frozen cadaveric knee specimens were potted into a hip simulator(femur) and a six degree-of-freedom load cell (tibia). Two rigid optical trackers were inserted into the proximal femur and distal tibia, allowing for the motion of the tibia with respect to the femur to be tracked during biomechanical tests. A series of points on the femur and tibia were digitised to create bone coordinate systems that were used to calculate the kinematic variables. Biomechanical testing involved applying a 5Nm internal rotation moment to the tibia while the knee was in full extension and tested sequentially in the following three conditions: i) ACLintact; ii) Partial ACL injury (ACLam) – anteromedial bundle sectioned; iii) Full ACL injury (ACLfull). The specimens were then randomised to either have the ALL sectioned first (ALLsec) followed by the LMPRsec or vice versa. Internal rotation and anterior translation of the tibia with respect to the femur were calculated. A mixed two-way (serial sectioning by ALL section order) repeated measures ANOVA (alpha = 0.05). Compared to the ACLintact condition, internal rotation was found to be 1.78° (p=0.06), 3.74° (p=0.001), and 3.84° (p=0.001) greater following ACLfull, LMPRsec and ALLsec respectively. LMPRsec and the ALLsec resulted in approximately 20 of additional internal rotation (p=0.004 and p=0.01, respectively) compared with the ACL deficient knee (ACLfull). No difference was observed between the ALL and LMPR sectioned states, or whether the ALL was sectioned before or after the LMPR (p=0.160). A trend of increasing anterior translation was observed when the 5Nm internal rotation moment was applied up until the ACL was fully sectioned; however, these differences were not significant (p=0.070). The ALL and LMPR seem to have a synergistic relationship in aiding the ACL in controlling anterolateral rotational laxity. High-grade anterolateral laxity following ACL injury may be attributed to injuries of the ALL and/or the LMPR. We suggest that the lateral meniscus should be thought of as part of the anterolateral capsulomeniscal complex (i.e., LM, ITB, and ALL) that acts as a stabiliser of anterolateral rotation in conjunction with the ACL.
Many factors can influence post-operative kinematics after total knee arthroplasty (TKA). These factors include intraoperative surgical conditions such as ligament release or quantity of bone resection as well as differences in implant design. Release of the medial collateral ligament (MCL) is commonly performed to allow correction of varus knee. Precise biomechanical knowledge of the individual components of the MCL is critical for proper MCL release during TKA. The purpose of this study was to define the influences of the deep medial collateral ligament (dMCL) and the posterior oblique ligament (POL) on valgus and rotatory stability in TKA. This study used six fresh-frozen cadaveric knees with intact cruciate ligaments. All TKA procedures were performed by the same surgeon using CR-TKA with a CT-free navigation system. Each knee was tested at 0°, 20°, 30°, 60°, and 90° of flexion. One sequential sectioning sequence was performed on each knee, beginning with an intact knee (S0), and thereafter femoral arthroplasty only (S1), tibial arthroplasty (S2), release of the dMCL (S3), and finally, release of the POL (S4). The same examiner applied all external load of 10 N-m valgus and a 5 N-m internal and external rotation torque at each flexion angle for the each cutting state. All data were analyzed statistically using one-way ANOVA and we investigated the correlation between the medial gap and the rotation angle. A significant difference was determined to be present for P < .05.Introduction
Materials and Methods
This in-vitro study finds which hip joint soft tissues act as primary and secondary passive internal and external rotation restraints so that informed decisions can be made about which soft tissues should be preserved or repaired during hip surgery. The capsular ligaments provide primary hip rotation restraint through a complete hip range of motion protecting the labrum from impingement. The labrum and ligamentum teres only provided secondary stability in a limited number of positions. Within the capsule, the iliofemoral lateral arm and ischiofemoral ligaments were primary restraints in two-thirds of the positions tested and so preservation/repair of these tissues should be a priority to prevent excessive hip rotation and subsequent impingement/instability for both the native hip and after hip arthroplasty.
The aim of this study was to quantify the stability
of fracture-implant complex in fractures after fixation. A total
of 15 patients with an undisplaced fracture of the femoral neck,
treated with either a dynamic hip screw or three cannulated hip
screws, and 16 patients with an AO31-A2 trochanteric fracture treated
with a dynamic hip screw or a Gamma Nail, were included. Radiostereometric
analysis was used at six weeks, four months and 12 months post-operatively
to evaluate shortening and rotation. Migration could be assessed in ten patients with a fracture of
the femoral neck and seven with a trochanteric fracture. By four
months post-operatively, a mean shortening of 5.4 mm (-0.04 to 16.1)
had occurred in the fracture of the femoral neck group and 5.0 mm
(-0.13 to 12.9) in the trochanteric fracture group. A wide range
of rotation occurred in both types of fracture. Right-sided trochanteric
fractures seem more rotationally stable than left-sided fractures. This prospective study shows that migration at the fracture site
occurs continuously during the first four post-operative months,
after which stabilisation occurs. This information may allow the
early recognition of patients at risk of failure of fixation. Cite this article:
We report our experience of revision total hip
replacement (THR) using the Revitan curved modular titanium fluted revision
stem in patients with a full spectrum of proximal femoral defects.
A total of 112 patients (116 revisions) with a mean age of 73.4
years (39 to 90) were included in the study. The mean follow-up
was 7.5 years (5.3 to 9.1). A total of 12 patients (12 hips) died
but their data were included in the survival analysis, and four
patients (4 hips) were lost to follow-up. The clinical outcome,
proximal bone regeneration and subsidence were assessed for 101
hips. The mean Harris Hip Score was 88.2 (45.8 to 100) after five years
and there was an increase of the mean Barnett and Nordin-Score,
a measure of the proximal bone regeneration, of 20.8 (-3.1 to 52.7).
Five stems had to be revised (4.3%), three (2.9%) showed subsidence,
five (4.3%) a dislocation and two of 85 aseptic revisions (2.3%)
a periprosthetic infection. At the latest follow-up, the survival with revision of the stem
as the endpoint was 95.7% (95% confidence interval 91.9% to 99.4%)
and with aseptic loosening as the endpoint, was 100%. Peri-prosthetic
fractures were not observed. We report excellent results with respect to subsidence, the risk
of fracture, and loosening after femoral revision using a modular
curved revision stem with distal cone-in-cone fixation. A successful
outcome depends on careful pre-operative planning and the use of
a transfemoral approach when the anatomy is distorted or a fracture
is imminent, or residual cement or a partially-secured existing
stem cannot be removed. The shortest appropriate stem should, in
our opinion, be used and secured with >
3 cm fixation at the femoral
isthmus, and distal interlocking screws should be used for additional
stability when this goal cannot be realised. Cite this article:
Background:. For hip prostheses, short stems allow easy insertion and reduce thigh pain risk, and are therefore suitable for Minimally Invasive Surgery. However, clinical outcome depends on sufficient initial fixation in the proximal femoral component. Revelation stems are designed to increase medullary cavity occupancy in the proximal femoral component and allow physiological load transmission within this component. Theoretically, on initial fixation of the proximal part of the stem, fixation remains unaffected by cutting the distal part of the stem. Recently, the Revelation micro MAX stem has become available. In this system, only the distal part of the stem is removed. To prepare for the introduction of this stem, we evaluated its rotational stability by installing it in the femurs of formalin-fixed cadavers. We then evaluated the time course of changes in bone density at the stem circumference and stem position by CT in the first eight patients undergoing hip arthroplasty. Subjects and Methods:. Micro MAX stems were inserted into the left femurs of one male and six female cadavers (76 to 95 years of age). A commonly used torque meter was mounted on the stem, and stem fixation was evaluated by the application of clockwise torque of 6 to 12 N-m. Further, in patients, three men and five women (age range 38–83 years, mean 67 years; two cases of femoral head necrosis, two of femoral neck fracture, and four of osteoarthritis of the hip) who underwent surgery with the micro MAX stem from July 2012 to April 2013 were evaluated at 3 weeks, and 3 and 6 months after surgery for stem insertion angle and stem subsidence by CT, and for bone density around the stem by the DEXE method. Results:.
The aims of this study were (1) to assess whether rotational stability testing in Gartland III supracondylar fractures can be used intra-operatively in order to assess fracture stability following fixation with lateral-entry wires and (2) to quantify the incidence of rotational instability following lateral-entry wire fixation in Gartland type III supracondylar humeral fractures in children. Twenty-one consecutive patients admitted with Grade III supracondylar fractures at the Children's Hospital at Westmead were surgically treated according to a predetermined protocol. Following closed fracture reduction, 2 lateral-entry wires were inserted under radiographic control. Stability was then assessed by comparing lateral x-ray images in internal and external rotation. If the fracture was found to be rotationally unstable by the operating surgeon, a third lateral-entry wire was inserted and images repeated. A medial wire was used only if instability was demonstrated after the insertion of three lateral wires.
To evaluate in-vivo the effectiveness of the double bundle technique for Anterior Cruciate ligament (ACL) reconstruction in restoring knee rotational stability under varying dynamic loading conditions. The study group included 10 patients who underwent double-bundle ACL reconstruction with hamstrings tendon autograft, 12 patients with single-bundle reconstruction, 10 ACL deficient subjects and 12 healthy control individuals. Kinematic and kinetic data were collected using an 8-camera optoelectronic motion analysis system and one force plate. Knee rotational stability was examined during two maneuvers: a combined 60o pivoting turn and immediate stairs ascend and a combined stairs descend and immediate 60o pivoting maneuver. The two factors evaluated were the maximum There were no significant differences in tibial rotation between the four groups in the examined maneuvers. Tibial rotation in the single- and the double-bundle groups were even lower than the control group. Rotational moments did not differ significantly between the four groups in any of the examined maneuvers. In general, rotational moments in the affected side of the ACL reconstructed and deficient groups were found reduced compared to the unaffected side. Double-bundle reconstruction does not reduce knee rotation further compared to the single-bundle technique during dynamic stability testing under varying conditions. The injured side of ACL reconstructed or deficient individuals is exposed to substantially lower rotational moment compared to the intact side.
To compare the early functional and clinical results, between single (SB) and double-bundle (DB) of Anterior Cruciate Ligament (ACL) reconstruction with hamstrings (HS). Thirty-six patients from 17 to 36 years old (average age 23), 22 ♂ and 14 ♀, from January 2006 to May 2008, were randomly allocated for ACL reconstruction with HS (SB – DB). Eighteen patients underwent a 4-stranded SB reconstruction (group A) and the remaining 18 underwent an anatomic, 2-stranded DB ACL reconstruction with 2 tibial and 2 femoral tunnel technique (group B), by using the Smith &
Nephew instrumentation system. The follow-up was from 8 to 22 months (average 16 months) for both groups and included clinical evaluation (pivot-shift test, anterior laxity test with KT-1000 arthrometer and Lysholm knee score) and radiographs. There were no statistically significant difference in the results between the 2 groups with regard to the pivot-shift test and the Lysholm score (SB: mean 91, DB: mean 89) (Mann-Whitney test, T-test). The anterior laxity was not significantly different between group A (mean, 2.2mm) and group B (mean, 0.9mm), according to KT-1000 measurements.
There are three basic concepts that are important to the biomechanics of pedicle screw-based instrumentation. First, the outer diameter of the screw determines pullout strength, while the inner diameter determines fatigue strength. Secondly, when inserting a pedicle screw, the dorsal cortex of the spine should not be violated and the screws on each side should converge and be of good length. Thirdly, fixation can be augmented in cases of severe osteoporosis or revision. A trajectory parallel or caudal to the superior endplate can minimise breakage of the screw from repeated axial loading. Straight insertion of the pedicle screw in the mid-sagittal plane provides the strongest
We report the use of an allograft prosthetic composite for reconstruction of the skeletal defect in complex revision total hip replacement for severe proximal femoral bone loss. Between 1986 and 1999, 72 patients (20 men, 52 women) with a mean age of 59.9 years (38 to 78) underwent reconstruction using this technique. At a mean follow-up of 12 years (8 to 20) 57 patients were alive, 14 had died and one was lost to follow-up. Further revision was performed in 19 hips at a mean of 44.5 months (11 to 153) post-operatively. Causes of failure were aseptic loosening in four, allograft resorption in three, allograft nonunion in two, allograft fracture in four, fracture of the stem in one, and deep infection in five. The survivorship of the allograft-prosthesis composite at ten years was 69.0% (95% confidence interval 67.7 to 70.3) with 26 patients remaining at risk. Survivorship was statistically significantly affected by the severity of the pre-operative bone loss (Paprosky type IV; p = 0.019), the number of previous hip revisions exceeding two (p = 0.047), and the length of the allograft used (p = 0.005).