Advertisement for orthosearch.org.uk
Results 1 - 15 of 15
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 36 - 36
22 Nov 2024
Goumenos S Hipfl C Michalski B Pidgaiska O Mewes M Stöckle U Perka C Meller S
Full Access

Background. Postoperative dislocation is one of the main surgical complications and the primary cause for revision surgery after 2-stage implant exchange due to periprosthetic infection of a total hip arthroplasty. Objective. The aims of our study were (1) to determine the incidence of dislocation after two-stage THA reimplantation without spacer placement, (2) to evaluate relevant risk factors for dislocation and (3) to assess the final functional outcome of those patients. Method. We prospectively analyzed 187 patients who underwent a two-stage total hip arthroplasty (THA) revision after being diagnosed with periprosthetic joint infection (PJI) from 2013 to 2019. The mean duration of follow-up was 54.2 ± 24.9 months (>36 months). The incidence of postoperative dislocation and subsequent revision was estimated through Kaplan-Meier curves and potential risk factors were identified using Cox hazard regression. The functional outcome of the patients was assessed using the modified Harris Hip Score (mHHS). Results. The estimated cumulative dislocation-free survival was 87.2% (95% CI: 81.2%-91.3%) with an estimated 10% and 12% risk for dislocation within the first 6 and 12 months, respectively. The use of a dual-mobility construct had no significant impact on the dislocation rate. Increasing body mass index (BMI) (HR=1.11, 95% CI: 1.02-1.19, p=0.011), abductor mechanism impairment (HR=2.85, 95% CI: 1.01-8.01, p=0.047), the extent of elongation of the affected extremity between stages (HR=1.04, 95% CI: 1.01-1.07, p=0.017), the final leg length discrepancy (HR=1.04, 95% CI: 1.01-1.08, p=0.018) and PJI recurrence (HR=2.76, 95% CI: 1.00-7.62, p=0.049) were found to be significant risk factors for dislocation. Overall revision rates were 17% after THA reimplantation. Dislocated hips were 62% more likely to undergo re-revision surgery (p<0.001, Log-rank= 78.05). A significant average increase of 30 points in mHHS scores after second-stage reimplantation (p=0.001, Wilcoxon-rank) was recorded, but no difference was noted in the final HHS measurements between stable and dislocated hips. Conclusion. Dislocation rates after 2-stage THA reimplantation for PJI remain high, especially regarding overweight or re-infected patients. Careful leg length restoration and an intact abductor mechanism seem critical to ensure stability in these complex patients


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 129 - 134
1 Jul 2021
Ayekoloye CI Abu Qa'oud M Radi M Leon SA Kuzyk P Safir O Gross AE

Aims

Improvements in functional results and long-term survival are variable following conversion of hip fusion to total hip arthroplasty (THA) and complications are high. The aim of the study was to analyze the clinical and functional results in patients who underwent conversion of hip fusion to THA using a consistent technique and uncemented implants.

Methods

A total of 39 hip fusion conversions to THA were undertaken in 38 patients by a single surgeon employing a consistent surgical technique and uncemented implants. Parameters assessed included Harris Hip Score (HHS) for function, range of motion (ROM), leg length discrepancy (LLD), satisfaction, and use of walking aid. Radiographs were reviewed for loosening, subsidence, and heterotopic ossification (HO). Postoperative complications and implant survival were assessed.


Bone & Joint Open
Vol. 2, Issue 6 | Pages 365 - 370
1 Jun 2021
Kolodychuk N Su E Alexiades MM Ren R Ojard C Waddell BS

Aims

Traditionally, acetabular component insertion during total hip arthroplasty (THA) is visually assisted in the posterior approach and fluoroscopically assisted in the anterior approach. The present study examined the accuracy of a new surgeon during anterior (NSA) and posterior (NSP) THA using robotic arm-assisted technology compared to two experienced surgeons using traditional methods.

Methods

Prospectively collected data was reviewed for 120 patients at two institutions. Data were collected on the first 30 anterior approach and the first 30 posterior approach surgeries performed by a newly graduated arthroplasty surgeon (all using robotic arm-assisted technology) and was compared to standard THA by an experienced anterior (SSA) and posterior surgeon (SSP). Acetabular component inclination, version, and leg length were calculated postoperatively and differences calculated based on postoperative film measurement.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1399 - 1408
1 Oct 2017
Scott CEH MacDonald D Moran M White TO Patton JT Keating JF

Aims

To evaluate the outcomes of cemented total hip arthroplasty (THA) following a fracture of the acetabulum, with evaluation of risk factors and comparison with a patient group with no history of fracture.

Patients and Methods

Between 1992 and 2016, 49 patients (33 male) with mean age of 57 years (25 to 87) underwent cemented THA at a mean of 6.5 years (0.1 to 25) following acetabular fracture. A total of 38 had undergone surgical fixation and 11 had been treated non-operatively; 13 patients died at a mean of 10.2 years after THA (0.6 to 19). Patients were assessed pre-operatively, at one year and at final follow-up (mean 9.1 years, 0.5 to 23) using the Oxford Hip Score (OHS). Implant survivorship was assessed. An age and gender-matched cohort of THAs performed for non-traumatic osteoarthritis (OA) or avascular necrosis (AVN) (n = 98) were used to compare complications and patient-reported outcome measures (PROMs).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 43 - 43
1 Apr 2017
Lombardi A
Full Access

The number one reason to consider large heads in total hip arthroplasty (THA) is for increased stability. Large diameter femoral heads substantially increase stability by virtue of increased range of motion and increased jump distance, which is the amount of displacement required to sublux the head out of the socket. Prevention is the best means for reducing dislocation, with requisites for stability being appropriate component position, restoration of leg length, and restoration of offset. In a review from our center studying the frequency of dislocation with small diameter femoral heads (≤32 mm) in 1262 patients (1518 hips) who underwent primary THA performed via a direct lateral approach, we observed a dislocation rate of 0.8% (12 of 1518). In a subsequent study of 1748 patients (2020 hips) who underwent primary THA at our center with large diameter heads (mean 43 mm, range 36–60 mm), we observed a substantially lower 0.04% frequency of dislocation (one of 2010) at a mean followup of 2.6 years. Our findings have been echoed in studies from several other centers. Howie et al. reported a prospective controlled trial of 644 low risk patients undergoing primary or revision THA randomised to receive either a 36 mm or 28 mm metal head articulated on highly crosslinked polyethylene. They observed significantly lower frequency of frequency of dislocation with 36 mm heads both overall (1.3%, 4 of 299 versus 5.4%, 17 of 216 with 28 mm heads, p=0.012) and in primary use (0.8%, 2 of 258 versus 4.4%, 12 of 275 with 28 mm heads, p=0.024), and a similar trend in their smaller groups of revision patients (5%, 2 of 41, versus 12%, 5 of 41 with 28 mm heads, p=0.273). Lachiewicz and Soileau reported on early and late dislocation with 36- and 40 mm heads in 112 patients (122 hips) at presumed high risk for dislocation who underwent primary THA. Risk factors were age >75 for 80 hips, proximal femur fracture for 18, history of contralateral dislocation for 2, history of alcohol abuse in 2, large acetabulum (>60 mm) in 6, and other reasons in 14. Early dislocation (<1 year) occurred in 4% (5 of 122), all with 36 mm heads. Late dislocation (>5 years) did not occur in any of the 74 patients with followup beyond 5 years. Stroh et al. compared 225 patients (248 hips) treated with THA using small diameter heads (<36 mm) to 501 patients (559 hips) treated with THA using large diameter heads (≥36 mm). There were no dislocations with large diameter heads compared with 1.8% (10 of 559) with small diameter heads. Allen et al. studied whether or not large femoral heads improve functional outcome after primary THA via the posterior approach in 726 patients. There were 399 done with small heads (<36 mm), 254 with medium heads (36 mm), and 73 with large heads (>36 mm), analyzed pre-operatively, at 6 months, and at 12 months. The authors could not find a correlation between increasing head size and improved function at one year, but observed that dislocation was reduced with large diameter heads. Optimization of hip biomechanics via proper surgical technique, component position, and restoration of leg length and offset are mandatory in total hip arthroplasty. Large heads enhance stability by increasing range of motion prior to impingement and enhancing jump stability


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 44 - 44
1 Dec 2016
Lombardi A
Full Access

The number one reason to consider large heads in total hip arthroplasty (THA) is for increased stability. Large diameter femoral heads substantially increase stability by virtue of increased range of motion and increased jump distance, which is the amount of displacement required to sublux the head out of the socket. Prevention is the best means for reducing dislocation, with requisites for stability being appropriate component position, restoration of leg length, and restoration of offset. In a review from our center studying the frequency of dislocation with small diameter femoral heads (≤32 mm) in 1262 patients (1518 hips) who underwent primary THA performed via a direct lateral approach, we observed a dislocation rate of 0.8% (12 of 1518). In a subsequent study of 1748 patients (2020 hips) who underwent primary THA at our center with large diameter heads (mean 43 mm, range 36–60 mm), we observed a substantially lower 0.04% frequency of dislocation (one of 2010) at a mean followup of 2.6 years. Our findings have been echoed in studies from several other centers. Howie et al. reported a prospective controlled trial of 644 low risk patients undergoing primary or revision THA randomised to receive either a 36 mm or 28 mm metal head articulated on highly crosslinked polyethylene. They observed significantly lower frequency of frequency of dislocation with 36 mm heads both overall (1.3%, 4 of 299 versus 5.4%, 17 of 216 with 28 mm heads, p=0.012) and in primary use (0.8%, 2 of 258 versus 4.4%, 12 of 275 with 28 mm heads, p=0.024), and a similar trend in their smaller groups of revision patients (5%, 2 of 41 versus 12%, 5 of 41 with 28 mm heads, p=0.273). Lachiewicz and Soileau reported on early and late dislocation with 36- and 40 mm heads in 112 patients (122 hips) at presumed high risk for dislocation who underwent primary THA. Risk factors were age >75 for 80 hips, proximal femur fracture for 18, history of contralateral dislocation for 2, history of alcohol abuse in 2, large acetabulum (>60 mm) in 6, and other reasons in 14. Early dislocation (<1 year) occurred in 4% (5 of 122), all with 36 mm heads. Late dislocation (>5 years) did not occur in any of the 74 patients with follow up beyond 5 years. Stroh et al. compared 225 patients (248 hips) treated with THA using small diameter heads (<36 mm) to 501 patients (559 hips) treated with THA using large diameter heads (≥36 mm). There were no dislocations with large diameter heads compared with 1.8% (10 of 559) with small diameter heads. Allen et al. studied whether or not large femoral heads improve functional outcome after primary THA via the posterior approach in 726 patients. There were 399 done with small heads (<36 mm), 254 with medium heads (36 mm), and 73 with large heads (>36 mm), analyzed preoperatively, at 6 months, and at 12 months. The authors could not find a correlation between increasing head size and improved function at one year, but observed that dislocation was reduced with large diameter heads. Optimization of hip biomechanics via proper surgical technique, component position, and restoration of leg length and offset are mandatory in total hip arthroplasty. Large heads enhance stability by increasing range of motion prior to impingement and enhancing jump stability


Bone & Joint 360
Vol. 4, Issue 5 | Pages 2 - 7
1 Oct 2015
Clark GW Wood DJ

The use of robotics in arthroplasty surgery is expanding rapidly as improvements in the technology evolve. This article examines current evidence to justify the usage of robotics, as well as the future potential in this emerging field.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 45 - 45
1 Aug 2013
Sankar B Deep K Changulani M Khan S Atiya S Deakin A
Full Access

INTRODUCTION

Leg length discrepancy following total hip arthroplasty (THA) can be functionally disabling for affected patients and can lead on to litigation issues. Assessment of limb length discrepancy during THA using traditional methods has been shown to produce inconsistent results. The aim of our study was to compare the accuracy of navigated vs. non navigated techniques in limb length restoration in THA.

METHODS

A dataset of 160 consecutive THAs performed by a single surgeon was included. 103 were performed with computer navigation and 57 were non navigated. We calculated limb length discrepancy from pre and post op radiographs. We retrieved the intra-operative computer generated limb length alteration data pertaining to the navigated group. We used independent sample t test and descriptive statistics to analyse the data.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 41 - 41
1 Aug 2013
Ecker T Steppacher S Haimerl M Murphy S
Full Access

Introduction. Correct postoperative leg length restoration is among the most important goals of hip arthroplasty. Therefore, we developed, validated and clinically applied a novel software algorithm based on surgical navigation, which allows the surgeon to restore a defined femur position without establishing a femoral coordinate system or the hip joint center and measure the leg length accurately and simply. Material and Methods. This new leg length algorithm was used in 154 hips (145 patients) that underwent CT-based computer-assisted THA (VectorVision Build 274 prototype; BrainLAB AG, Helmstetten, Germany) with a tissue preserving superior capsulotomy. Intraoperatively, a pelvic and a femoral dynamic reference bases (DRB) were applied and the anterior pelvic plane (APP) was set as the pelvic coordinate system. Then, the hip joint was put in a neutral position and this position, and the relative position of the femoral DRB relative to the pelvic DRB, was captured and stored by the navigation system. After implantation of the prosthesis the same above described femoral position with the same amplitude of flexion/extension, abduction/adduction and rotation was restored. Now, any resulting difference was due to linear changes. Validation of this new algorithm was performed by comparing the navigated results to measurements from calibrated antero-posterior pre- and postoperative radiographs. The radiographic results were compared to the mean leg length change measured with the navigation system. Results. No significant difference was found between radiographic leg length change and the results from the navigation system (p=0.658). The mean difference between the radiographic results and the results from the navigation system was −0.5 (1–8 mm (range, −5–4 mm). The mean registration accuracy of the navigation system was 2.04 (0.58 mm (range, 0.70–3.00 mm). Discussion. This novel tool has the potential to increase the accuracy and consistency of leg-length change measurement during hip arthroplasty. Improved methods of measuring leg length change during surgery are even more critical now, when smaller incisions are being used, because traditional mechanical measurement methods are potentially even more unreliable than they are when larger exposures are used. This current method of measuring leg length change eliminates the need to calculate the center of rotation of the arthritic hip joint, which is often not accurately possible, and eliminates the need to establish a femoral coordinate system, which can be time consuming and frustrating. Besides registration accuracy, validation with plain radiographs is another potential source of error. Nonetheless, there was a substantial agreement between the radiographic results and the results from the navigation system. This novel computer-assisted method represents an accurate and simple tool for intraoperative leg length measurement


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1468 - 1474
1 Nov 2012
Hill JC Archbold HAP Diamond OJ Orr JF Jaramaz B Beverland DE

Restoration of leg length and offset is an important goal in total hip replacement. This paper reports a calliper-based technique to help achieve these goals by restoring the location of the centre of the femoral head. This was validated first by using a co-ordinate measuring machine to see how closely the calliper technique could record and restore the centre of the femoral head when simulating hip replacement on Sawbone femur, and secondly by using CT in patients undergoing hip replacement. Results from the co-ordinate measuring machine showed that the centre of the femoral head was predicted by the calliper to within 4.3 mm for offset (mean 1.6 (95% confidence interval (CI) 0.4 to 2.8)) and 2.4 mm for vertical height (mean -0.6 (95% CI -1.4 to 0.2)). The CT scans showed that offset and vertical height were restored to within 8 mm (mean -1 (95% CI -2.1 to 0.6)) and -14 mm (mean 4 (95% CI 1.8 to 4.3)), respectively. Accurate assessment and restoration of the centre of the femoral head is feasible with a calliper. It is quick, inexpensive, simple to use and can be applied to any design of femoral component


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 61 - 64
1 Nov 2012
Mayle Jr RE Paprosky WG

Revision total hip arthroplasty (THA) is projected to increase by 137% from the years 2005 to 2030. Reconstruction of the femur with massive bone loss can be a formidable undertaking. The goals of revision surgery are to create a stable construct, preserve bone and soft tissues, augment deficient host bone, improve function, provide a foundation for future surgery, and create a biomechanically restored hip. Options for treatment of the compromised femur include: resection arthroplasty, allograft prosthetic composite (APC), proximal femoral replacement, cementless fixation with a modular tapered fluted stem, and impaction grafting. The purpose of this article is to review the treatment options along with their associated outcomes in the more severe femoral defects (Paprosky types IIIb and IV) in revision THA.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1586 - 1591
1 Dec 2007
Flecher X Parratte S Aubaniac J Argenson J

A clinical and radiological study was conducted on 97 total hip replacements performed for congenital hip dislocation in 79 patients between 1989 and 1998 using a three-dimensional custom-made cementless stem. The mean age at operation was 48 years (17 to 72) and the mean follow-up was for 123 months (83 to 182).

According to the Crowe classification, there were 37 class I, 28 class II, 13 class III and 19 class IV hips. The mean leg lengthening was 25 mm (5 to 58), the mean pre-operative femoral anteversion was 38.6° (2° to 86°) and the mean correction in the prosthetic neck was −23.6° (−71° to 13°). The mean Harris hip score improved from 58 (15 to 84) to 93 (40 to 100) points. A revision was required in six hips (6.2%). The overall survival rate was 89.5% (95% confidence interval 89.2 to 89.8) at 13 years when two hips were at risk.

This custom-made cementless femoral component, which can be accommodated in the abnormal proximal femur and will correct the anteversion and frontal offset, provided good results without recourse to proximal femoral corrective osteotomy.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 80 - 88
1 Jan 2007
El-Rosasy MA

We have managed 21 patients with a fracture of the tibia complicated by bone and soft-tissue loss as a result of an open fracture in 10, or following debridement of an infected nonunion in 11, by resection of all the devitalised tissues, acute limb shortening to close the defect, application of an external fixator and metaphyseal osteotomy for re-lengthening. The mean bone loss was 4.7 cm (3 to 11). The mean age of the patients was 28.8 years (12 to 54) and the mean follow-up was 34.8 months (24 to 75).

All the fractures united with a well-aligned limb. The mean duration of treatment for the ten grade-III A+B open fractures (according to the Gustilo-Anderson classification) was 5.7 months (4.5 to 8) and for the nonunions, 7.6 months (5.5 to 12.5). Complications included one refracture, one transient palsy of the peroneal nerve and one equinus contracture of 10°.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 184 - 185
1 Feb 2004
Tsamatropoulos P Theos C Tsatsoulis D Pallas I Palantza E Athanasopoulou A Thomas E
Full Access

Reconstruction acetabular surgery with bone stock loss is still a difficult and challenging problem for the orthopaedic surgeon. The goals of acetabular revision are: stable bone coverage that can support the new acetabular component, restoration of the anatomy and bone stock for future revisions, equalization of leg length and restoration of the centre of hip motion. These goals are difficult to achieve when the pelvic defect is particularly severe. We examine the case of a female 73 years old who underwent a third revision arthroplasty of the hip joint because of extensive bony defect of the acetabular cavity (massive protrusio defect-type III –D’Antonio- combined segmental/cavitary acetabular defect). The femoral component which was revised in a previous operation with a mega stem (type Kotz), was radiologically stable and symptomless. Preoperative radiological assessment was performed using standard radiographic views, Judet views and CT scan. The surgical approach that we used was a slight modification of the previous incision achieving a better visualization of the entire acetabulum and iliac wing. The loose acetabular cup as well as soft tissue and debris were removed from the acetabulum. The large acetabular defect was filled with a massive allograft (tibial plateau) properly cut and shaped. The stability of the allograft was achieved fixing the allograft to the iliac bone with screws. A large amount of particulate allograft bone was placed in the depths of the acetabular defect restoring a proper level of the acetabular floor. Then a Burke-Schneider cage was firmly seated and fixed with screws in the prepared acetabular bed. A polyethylene cup was cemented into the acetabular shell. The superior part of the Kotz femoral prosthesis was also revised with a new one. Postoperatively we din not have any complications, the graft incorporation was successful with a satisfactory functional result. We believe that the use of structural allograft bone is essential for the reconstruction of large segmentalace-tabular defects. The results however are less predictable because of important technical difficulties and sometimes serious complications occur


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 173 - 173
1 Jul 2002
Bourne R
Full Access

Dislocation of a total hip replacement is a devastating event from the patient perspective. Patient (neuromuscular disease, DDH, revision), surgical approach, soft tissue balancing, and implant factors (head-neck ratio, neck design, offset) all play a role. Most hip dislocations occur early, but dislocation can often occur late due to wear-induced head/neck impingement. Early reduction and preventative measures are effective in preventing further dislocation in about 70% of patients. Revision surgery for dislocation is effective in only three quarters of patients. In elderly, low demand patients, constrained/ capture cups are an effective option. Prevention of dislocation is obviously the key and involves patient selection, preoperative planning, leg length/offset restoration, and choice of a total hip replacement, which minimises head/neck impingement