Advertisement for orthosearch.org.uk
Results 1 - 20 of 75
Results per page:
Bone & Joint Open
Vol. 5, Issue 12 | Pages 1092 - 1100
8 Dec 2024
Fraser E Spence S Farhan-Alanie OM Doonan J Mahendra A Gupta S

Aims

Limb salvage surgery (LSS) is the primary treatment option for primary bone malignancy. It involves the removal of bone and tissue, followed by reconstruction with endoprosthetic replacements (EPRs) to prevent amputation. Trabecular metal (TM) collars have been developed to encourage bone ingrowth (osseointegration (OI)) into EPRs. The primary aim of this study was to assess whether OI occurs when TM collars are used in EPRs for tumour.

Methods

A total of 124 patients from July 2010 to August 2021 who underwent an EPR for tumour under the West of Scotland orthopaedic oncology team were identified. Overall, 81 patients (65%) met the inclusion criteria, and two consultants independently analyzed radiographs at three and 12 months, as well as the last radiograph, using a modified version of the Stanford Radiological Assessment System.


Aims

This study intended to investigate the effect of vericiguat (VIT) on titanium rod osseointegration in aged rats with iron overload, and also explore the role of VIT in osteoblast and osteoclast differentiation.

Methods

In this study, 60 rats were included in a titanium rod implantation model and underwent subsequent guanylate cyclase treatment. Imaging, histology, and biomechanics were used to evaluate the osseointegration of rats in each group. First, the impact of VIT on bone integration in aged rats with iron overload was investigated. Subsequently, VIT was employed to modulate the differentiation of MC3T3-E1 cells and RAW264.7 cells under conditions of iron overload.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 23 - 23
24 Nov 2023
Xie C Ren Y Weeks J Lekkala S Rainbolt J Xue T Shu Y Lee K de Mesy Bentley KL Yeh S Schwarz E
Full Access

Title. Longitudinal Intravital Imaging to Quantify the “Race for the Surface” Between Host Immune Cell and Bacteria for Orthopaedic Implants with S. aureus Colonization in a Murine Model. Aim. To assess S. aureus vs. host cell colonization of contaminated implants vis intravital multiphoton laser scanning microscopy (IV-MLSM) in a murine model. Method. All animal experiments were approved by IACUC. A flat stainless steel or titanium L-shaped pin was contaminated with 10. 5. CFU of a red fluorescent protein (RFP) expressing strain of USA300LAC, and surgically implanted through the femur of global GFP-transgenic mice. IV-MLSM was performed at 2, 4, and 6 hours post-op. Parallel cross-sectional CFU studies were performed to quantify the bacteria load on the implant at 2,4,6,12,18 and 24 hours. Results. 1) We developed a high-fidelity reproducible IV-MLSM system to quantify S. aureus and host cell colonization of a bone implant in the mouse femur. Proper placement of all implants were confirmed with in vivo X-rays, and ex vivo photos. We empirically derive the ROI during each imaging session by aggregating the imaged volume which ranges from (636.4um × 636.4um × 151um) = 0.625 +/- 0.014 mm. 3. of bone marrow in a global GFP-transgenic mouse. 2) IV-MLSM imaging acquisition of the “race for the surface”.In vitro MPLSM images of implants partially coated with USA300LAC (RFP-MRSA) were verified by SEM image. Results from IV-MLSM of RFP-MRSA and GFP. +. host cell colonization of the contaminated implants illustrated the mutually exclusive surface coating at 3hrs, which to our knowledge is the first demonstration of “the race for the surface” between bacteria and host cells via intravital microscopy. 3) Quantifying the “race for the surface” with CFU verification of S. aureus on the implant. 3D volumetric rendering of the GFP. +. voxels and RFP+ voxels within the ROI were generated in Imaris. The voxel numbers suggeste that the fight for the surface concludes ∼3hrs post-infection, and then transitions to an aggressive MRSA proliferation phase. The results of WT control demonstrate a significant increase in CFU by 12hrs post-op for both stainless steel (P<0.01) and titanium (P<0.01). Conclusions. We developed IV-MLSM to quantify the “Race for the Surface” between host cells and contaminating S. aureus in a murine femur implant model. This race is remarkably fast, as the implant surface is completely covered with 3hrs, peak bacterial growth on the implant occurs between 2 and 12 hours and is complete by 12hrs


Bone & Joint Open
Vol. 4, Issue 5 | Pages 329 - 337
8 May 2023
Khan AQ Chowdhry M Sherwani MKA McPherson EJ

Aims

Total hip arthroplasty (THA) is considered the preferred treatment for displaced proximal femoral neck fractures. However, in many countries this option is economically unviable. To improve outcomes in financially disadvantaged populations, we studied the technique of concomitant valgus hip osteotomy and operative fixation (VOOF). This prospective serial study compares two treatment groups: VOOF versus operative fixation alone with cannulated compression screws (CCSs).

Methods

In the first series, 98 hip fixation procedures were performed using CCS. After fluoroscopic reduction of the fracture, three CCSs were placed. In the second series, 105 VOOF procedures were performed using a closing wedge intertrochanteric osteotomy with a compression lag screw and lateral femoral plate. The alignment goal was to create a modified Pauwel’s fracture angle of 30°. After fluoroscopic reduction of fracture, lag screw was placed to achieve the calculated correction angle, followed by inter-trochanteric osteotomy and placement of barrel plate. Patients were followed for a minimum of two years.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 129 - 129
4 Apr 2023
Adla P Iqbal A Sankar S Mehta S Raghavendra M
Full Access

Intraoperative fractures although rare are one of the complications known to occur while performing a total hip arthroplasty (THA). However, due to lower incidence rates there is currently a gap in this area of literature that systematically reviews this important issue of complications associated with THA. Method: We looked into Electronic databases including PubMed, Cochrane Central Register of Controlled Trials (CENTRAL), the archives of meetings of orthopaedic associations and the bibliographies of included articles and asked experts to identify prospective studies, published in any language that evaluated intra-operative fractures occurring during total hip arthroplasty from the year 1950-2020. The screening, data extraction and quality assessment were carried out by two researchers and if there was any discrepancy, a third reviewer was involved. Fourteen studies were identified. The reported range of occurrence of fracture while performing hip replacement surgery was found to be 0.4-7.6%. Major risk factors identified were surgical approaches, Elderly age, less Metaphyseal-Diaphyseal Index score, change in resistance while insertion of the femur implants, inexperienced surgeons, uncemented femoral components, use of monoblock elliptical components, implantation of the acetabular components, patients with ankylosing spondylitis, female gender, uncemented stems in patients with abnormal proximal femoral anatomy and with cortices, different stem designs, heterogeneous fracture patterns and toothed design. Intraoperative fractures during THA were managed with cerclage wire, femoral revision, intramedullary nail and cerclage wires, use of internal fixation plates and screws for management of intra operative femur and acetabular fractures. The main reason for intraoperative fracture was found to be usage of cementless implants but planning and timely recognition of risk factors and evaluating them is important in management of intraoperative fractures. Adequate surgical site exposure is critical especially during dislocation of hip, reaming of acetabulum, impaction of implant and preparing the femoral canal for stem insertion. Eccentric and increased reaming of acetabulum to accommodate a larger cup is to be avoided, especially in females and elderly patients as the acetabulum is thinner. However, this area requires more research in order to obtain more evidence on effectiveness, safety and management of intraoperative fractures during THA


Bone & Joint Research
Vol. 11, Issue 10 | Pages 700 - 714
4 Oct 2022
Li J Cheung W Chow SK Ip M Leung SYS Wong RMY

Aims

Biofilm-related infection is a major complication that occurs in orthopaedic surgery. Various treatments are available but efficacy to eradicate infections varies significantly. A systematic review was performed to evaluate therapeutic interventions combating biofilm-related infections on in vivo animal models.

Methods

Literature research was performed on PubMed and Embase databases. Keywords used for search criteria were “bone AND biofilm”. Information on the species of the animal model, bacterial strain, evaluation of biofilm and bone infection, complications, key findings on observations, prevention, and treatment of biofilm were extracted.


Bone & Joint Research
Vol. 11, Issue 2 | Pages 73 - 81
22 Feb 2022
Gao T Lin J Wei H Bao B Zhu H Zheng X

Aims

Trained immunity confers non-specific protection against various types of infectious diseases, including bone and joint infection. Platelets are active participants in the immune response to pathogens and foreign substances, but their role in trained immunity remains elusive.

Methods

We first trained the innate immune system of C57BL/6 mice via intravenous injection of two toll-like receptor agonists (zymosan and lipopolysaccharide). Two, four, and eight weeks later, we isolated platelets from immunity-trained and control mice, and then assessed whether immunity training altered platelet releasate. To better understand the role of immunity-trained platelets in bone and joint infection development, we transfused platelets from immunity-trained mice into naïve mice, and then challenged the recipient mice with Staphylococcus aureus or Escherichia coli.


Bone & Joint Research
Vol. 11, Issue 2 | Pages 102 - 111
1 Feb 2022
Jung C Cha Y Yoon HS Park CH Yoo J Kim J Jeon Y

Aims

In this study, we aimed to explore surgical variations in the Femoral Neck System (FNS) used for stable fixation of Pauwels type III femoral neck fractures.

Methods

Finite element models were established with surgical variations in the distance between the implant tip and subchondral bone, the gap between the plate and lateral femoral cortex, and inferior implant positioning. The models were subjected to physiological load.


There is a strong association between the presence of a calcar collar on a cementless stem and a reduced risk of revision surgery for periprosthetic fracture of the femur (PFF). A medial calcar collar may act to reduce relative movement between the implant and femur during PFF, through calcar-collar contact (CCC). The aims were:. Estimate the effect of CCC on periprosthetic fracture mechanics. Estimate the effect of initial calcar-collar separation on the likelihood of CCC. Three groups of six composite femurs were implanted with a fully coated collared cementless femoral stem. Neck resection differed between groups (group 1 = no additional resection, group 2 = 3mm additional resection, group 3 = 6mm additional resection). PFF were simulated using a previously published technique. Fracture torque and rotational displacement were measured and torsional stiffness and rotational work prior to fracture were estimated. Results between trials where CCC did and did not occur where compared using Mann-Whitney U tests. Logistic regression estimated the odds (OR) of failing with 95% confidence interval (CI) to achieve CCC for a given initial separation. Where CCC occurred fracture torque was greater (47.33 [41.03 to 50.45] Nm versus 38.26 [33.70 to 43.60] Nm, p= 0.05) and torsional stiffness was greater (151.38 [123.04 to 160.42] rad.Nm. −1. versus 96.86 [84.65 to 112.98] rad.Nm. −1. , p <0.01). CCC was occurred in all cases in group one, 50% in group two and 0% in group three. OR of failure to obtain CCC increased 3.8 fold (95% CI 1.6 to 30.2, p <0.05) for each millimetre of separation. Resistance to fracture and construct stiffness increased when a the collar made contact with the calcar prior to fracture and the chances of contact decrease with increasing initial separation at the time of implantation. Surgeons should aim to achieve a calcar-collar distance of less than 1mm following implantation to ensure CCC and to reduce the risk of fracture


Bone & Joint Open
Vol. 2, Issue 7 | Pages 466 - 475
8 Jul 2021
Jain S Lamb J Townsend O Scott CEH Kendrick B Middleton R Jones SA Board T West R Pandit H

Aims

This study evaluates risk factors influencing fracture characteristics for postoperative periprosthetic femoral fractures (PFFs) around cemented stems in total hip arthroplasty.

Methods

Data were collected for PFF patients admitted to eight UK centres between 25 May 2006 and 1 March 2020. Radiographs were assessed for Unified Classification System (UCS) grade and AO/OTA type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (polished taper-slip (PTS) vs composite beam (CB)). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (ORs) with 95% confidence intervals (CIs). Surgical treatment (revision vs fixation) was compared by UCS grade and AO/OTA type.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 102 - 102
1 Mar 2021
Kohli N De Eguilior Caballero JR Ghouse S Van Arkel R
Full Access

Abstract. Introduction. The long-term biological success of cementless orthopaedic prostheses is highly dependent on osteointegration. Pre-clinical testing of new cementless implant technology however, requires live animal testing, which has anatomical, loading, ethical and cost challenges. This proof-of-concept study aimed to develop an in vitro model to examine implant osteointegration under known loading/micromotion conditions. Methods. Fresh cancellous bone cylinders (n=8) were harvested from porcine femur and implanted with additive manufactured porous titanium implants (Ø4 × 15 mm). To simulate physiological conditions, n=3 bone cylinders were tested in a bioreactor system with a cyclic 30 µm displacement at 1Hz for 300 cycles every day for 15 days in a total of 21 days culture. The chamber was also perfused with culture medium using a peristaltic pump. Control bone cylinders were cultured under static conditions (n=5). Samples were calcein stained at day 7. Post-testing, bone cylinders were formalin fixed and bony ingrowth was measured via microscopy. Results. Viability of the freshly harvested ex vivo bone cylinders was maintained for up to 28 days. Two samples remain unanalysed due to COVID lockdown, one in each group. Similar to osteointegration seen in live animal models, evidence of bony ingrowth was seen more markedly at the bone-implant interface under dynamic conditions. This was evident by a greater intensity of calcein staining, confirming the deposition of new bone, at the bone-implant interface. In comparison, under static conditions, calcein staining was observed randomly all over the cylinder. Conclusion. This proof-of-concept study demonstrates that implant bony adaptation and ingrowth can be measured in vitro under known cyclic micromotion/loading conditions. This comparatively low cost, low ethical impact, controlled loading laboratory method has potential to accelerate the rate of implant development whilst conforming with the principles of NC3Rs. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 19 - 19
1 Mar 2021
Lamb J Coltart O Adekanmbi I Stewart T Pandit H
Full Access

Abstract. Objective. To estimate the effect of calcar collar contact on periprosthetic fracture mechanics using a collared fully coated cementless femoral stem. Methods. Three groups of six composite femurs were implanted with a fully coated collared cementless femoral stem. Neck resection was increased between groups (group 1 = normal, group 2 = 3mm additional, group 3 = 6mm additional), to simulate failure to obtain calcar collar contact. Periprosthetic fractures of the femur were simulated using a previously published technique. Fracture torque and rotational displacement were measured and torsional stiffness and rotational work prior to fracture were estimated. High speed video recording identified if collar to calcar contact (CCC) occurred. Results between trials where calcar contact did and did not occur where compared using Mann-Whitney U tests. Results. Where CCC occurred versus where no CCC occurred, fracture torque was greater (47.33 [41.03 to 50.45] Nm versus 38.26 [33.70 to 43.60] Nm, p= 0.05), Rotational displacement was less (0.29 [0.27 to 0.39] rad versus 0.37 [0.33 to 0.49] rad, p= 0.07), torsional stiffness was greater (151.38 [123.04 to 160.42] rad. Nm-1 versus 96.86 [84.65 to 112.98] rad.Nm-1, p <0.01) and rotational work was similar (5.88 [4.67, 6.90] J versus 5.31 [4.40, 6.56] J, p= 0.6). Conclusions. Resistance to fracture and construct stiffness increased when a collared cementless stem made contact with the femoral calcar prior to fracture. These results demonstrate that calcar-collar contact and not a calcar collar per se, is crucial to maximising the protective effect of a medial calcar collar on the risk of post-operative periprosthetic fractures of the femur. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 41 - 41
1 Mar 2021
Lamb J Coltart O Adekanmbi I Stewart T Pandit H
Full Access

Abstract. Objective. To estimate the effect of calcar collar separation on the likelihood of calcar collar contact during in vitro periprosthetic fracture. Methods. Three groups of six composite femurs were implanted with a collared cementless femoral stem. Neck resection was increased between groups (group 1 = normal, group 2 = 3mm additional, group 3 = 6mm additional), to simulate failure to obtain calcar collar contact. Prior to each trial, the distances between anterior (ACC) and posterior (PCC) collar and the calcar were measured. Periprosthetic fractures of the femur were simulated using a previously published technique. High speed video recording identified when collar to calcar contact (CCC) occurred. The ACC and PCC were compared between trials where the CCC was and was not achieved. Regression estimated the odds of failing to achieve CCC for a given ACC or PCC. Results. CCC was achieved prior to fracture in all cases in group one, 50% in group two and 0% in group three. The median (range) ACC for those trials where CCC was achieved was 0.40 (0.00, 3.37) mm versus 6.15 (3.06 to 6.88) mm, where CCC was not achieved (p <0.01). The median (range) PCC for those trials where CCC was achieved was 0.85 (0.00 to 3.71) mm versus 5.97 (2.23 to 7.46) mm, where CCC was not achieved (p <0.01). Binomial logistic regression estimated risk of failure to obtain CCC increased 3.8 fold (95% confidence interval 1.6 to 30.2, p <0.05) for each millimetre of PCC. Conclusions. Increased separation between collar and calcar reduced the likelihood of calcar collar contact during a simulated periprosthetic fracture of the femur. Surgeons should aim to achieve a calcar-collar distance of less than 1mm following implantation to ensure calcar collar contact during periprosthetic femoral fracture and to reduce the risk of fracture. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Bone & Joint Research
Vol. 10, Issue 3 | Pages 156 - 165
1 Mar 2021
Yagi H Kihara S Mittwede PN Maher PL Rothenberg AC Falcione ADCM Chen A Urish KL Tuan RS Alexander PG

Aims

Periprosthetic joint infections (PJIs) and osteomyelitis are clinical challenges that are difficult to eradicate. Well-characterized large animal models necessary for testing and validating new treatment strategies for these conditions are lacking. The purpose of this study was to develop a rabbit model of chronic PJI in the distal femur.

Methods

Fresh suspensions of Staphylococcus aureus (ATCC 25923) were prepared in phosphate-buffered saline (PBS) (1 × 109 colony-forming units (CFUs)/ml). Periprosthetic osteomyelitis in female New Zealand white rabbits was induced by intraosseous injection of planktonic bacterial suspension into a predrilled bone tunnel prior to implant screw placement, examined at five and 28 days (n = 5/group) after surgery, and compared to a control aseptic screw group. Radiographs were obtained weekly, and blood was collected to measure ESR, CRP, and white blood cell (WBC) counts. Bone samples and implanted screws were harvested on day 28, and processed for histological analysis and viability assay of bacteria, respectively.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 3 - 3
1 Feb 2021
Hwang E Braly H Ismaily S Noble P
Full Access

INTRODUCTION. The increasing incidence of periprosthetic femoral fractures (PFF) after total hip arthroplasty presents growing concerns due to challenges in treatment and increased mortality. PFF are often observed when the prosthesis is implanted in varus, especially with blade-type stems. To help elucidate its impact on the PFF risk, the specific research question is: What is the effect of misalignment of a blade-type stem (resulting in down-sized prosthesis) on 1)the distribution and magnitude of cortical stresses and 2)implant-bone micromotion. METHOD. We developed two finite element models consisting of an average female femur implanted within a generic blade-type stem prosthesis, (i)in neutral alignment, and (ii)oriented in 5° of varus, coupled with corresponding down-sizing of the prosthesis. Each model consisted of 1.1million elements, while the average mesh length at the implant-bone interface was 0.4mm. Elastic moduli of 15GPa(cortex), 150MPa(trabecular bone), and 121GPa(implant), and Poisson's ratio of 0.3 were assumed. The distal end was fixed and the interface was defined as a surface-to-surface contact with friction coefficients (dynamic 0.3; static 0.4). Walking and stair-climbing were simulated by loading the joint contact and muscle forces after scaling to the subjects’ body weight. The peak von Mises stress and the average stress within the surface having 1cm diameter and the center at where the peak stress occurred at each contacting area, the interfacial micromotion along medial, lateral side were analyzed. For statistical analysis, two-tailed t-test was performed between the neutral and varus cases over four loading cycles with significance level of p<0.05. RESULTS. Neutral alignment led to three areas of cortical/implant contact with focal load transfer via those areas, whereas varus placement limited to two areas (Figure 1). In both simulations, the greatest stress was observed at the proximal medial contact. With varus, average and peak stresses increased by 39% and 65% during walking and 28% and 35% during stair-climbing, respectively (Table 1). Micromotion was greatest over the proximal third of the interface, especially along lateral side (Figure 2). The 90. th. percentile values with the varus exceeded the neutral by 35% with walking and 28% with stair-climbing over the lateral interface. DISCUSSION. The proximal medial location of the greatest stress correlates well with clinical observations in PFF involving a posteromedial calcar fragment. Based on current lesser stress than the reported yield stress, loading during daily living activities may result in microdamage rather than an immediate PFF. However, impact loading such as hammering for stem insertion may introduce PFF at the location, especially with in varus. The increase in interfacial micromotion is expected to lead to increase in the risk for implant loosening, also leading to PFF. Further study is needed to confirm the validity and generalizability of these findings. SIGNIFICANCE/CLINICAL RELEVANCE. This study demonstrates the importance of proper alignment of femoral stems of a blade-type design. The misalignment (resulting in down-sizing) increased stress up to 65% and micromotion up to 35% around prosthesis, even during daily activities, thus increased attention to proper implant alignment and sizing is suggested when using components of this design. For any figures or tables, please contact the authors directly


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 709 - 715
1 Jun 2020
Abdelsamie KR Elhawary I Ali H Ali M EL-Shafie M Dominic Meek RM

Aims. Femoral revision component subsidence has been identified as predicting early failure in revision hip surgery. This comparative cohort study assessed the potential risk factors of subsidence in two commonly used femoral implant designs. Methods. A comparative cohort study was undertaken, analyzing a consecutive series of patients following revision total hip arthroplasties using either a tapered-modular (TM) fluted titanium or a porous-coated cylindrical modular (PCM) titanium femoral component, between April 2006 and May 2018. Clinical and radiological assessment was compared for both treatment cohorts. Risk factors for subsidence were assessed and compared. Results. In total, 65 TM and 35 PCM cases were included. At mean follow-up of seven years (1 to 13), subsidence was noted in both cohorts during the initial three months postoperatively (p < 0.001) then implants stabilized. Subsidence noted in 58.7% (38/65 cases) of the TM cohort (mean 2.3 mm, SD 3.5 mm) compared to 48.8% (17/35) of PCM cohort (mean 1.9 mm, SD 2.6 mm; p = 0.344). Subsidence of PCM cohort were significantly associated with extended trochanteric osteotomy (ETO) (p < 0.041). Although the ETO was used less frequently in PCM stem cohort (7/35), subsidence was noted in 85% (6/7) of them. Significant improvement of the final mean Oxford Hip Score (OHS) was reported in both treatment groups (p < 0.001). Conclusion. Both modular TM and PCM revision femoral components subsided within the femur. TM implants subsided more frequently than PCM components if the femur was intact but with no difference in clinical outcomes. However, if an ETO is performed then a PCM component will subside significantly more and suggests the use of a TM implant may be advisable. Cite this article: Bone Joint J 2020;102-B(6):709–715


Bone & Joint Research
Vol. 9, Issue 6 | Pages 314 - 321
1 Jun 2020
Bliven E Sandriesser S Augat P von Rüden C Hackl S

Aims. Evaluate if treating an unstable femoral neck fracture with a locking plate and spring-loaded telescoping screw system would improve construct stability compared to gold standard treatment methods. Methods. A 31B2 Pauwels’ type III osteotomy with additional posterior wedge was cut into 30 fresh-frozen femur cadavers implanted with either: three cannulated screws in an inverted triangle configuration (CS), a sliding hip screw and anti-rotation screw (SHS), or a locking plate system with spring-loaded telescoping screws (LP). Dynamic cyclic compressive testing representative of walking with increasing weight-bearing was applied until failure was observed. Loss of fracture reduction was recorded using a high-resolution optical motion tracking system. Results. LP constructs demonstrated the highest mean values for initial stiffness and failure load. LP and SHS constructs survived on mean over 50% more cycles and to loads 450 N higher than CS. During the early stages of cyclic loading, mean varus collapse of the femoral head was 0.5° (SD 0.8°) for LP, 0.7° (SD 0.7°) for SHS, and 1.9° (SD 2.3°) for CS (p = 0.071). At 30,000 cycles (1,050 N) mean femoral neck shortening was 1.8 mm (SD 1.9) for LP, 2.0 mm (SD 0.9) for SHS, and 3.2 mm (SD 2.5) for CS (p = 0.262). Mean leg shortening at construct failure was 4.9 mm (SD 2.7) for LP, 8.9 mm (SD 3.2) for SHS, and 7.0 mm (SD 4.3) for CS (p = 0.046). Conclusion. Use of the LP system provided similar (hip screw) or better (cannulated screws) biomechanical performance as the current gold standard methods suggesting that the LP system could be a promising alternative for the treatment of unstable fractures of the femoral neck. Cite this article: Bone Joint Res 2020;9(6):314–321


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 285 - 292
1 Mar 2020
Tanaka A Katagiri H Murata H Wasa J Miyagi M Honda Y Takahashi M

Aims

The aim of this study is to evaluate the clinical results of operative intervention for femoral metastases which were selected based on expected survival and to discuss appropriate surgical strategies.

Methods

From 2002 to 2017, 148 consecutive patients undergoing surgery for femoral metastasis were included in this study. Prognostic risk assessments were performed according to the Katagiri and revised Katagiri scoring system. In general, the low-risk group underwent resection and reconstruction with endoprosthetic replacement (EPR), while the high-risk group underwent internal fixation (IF) and radiation therapy. For the intermediate-risk group, the operative choice depended on the patient’s condition, degree of bone destruction, and radio-sensitivity. Overall survival, local failure, walking ability, and systemic complications were evaluated.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 142 - 142
1 Feb 2020
Nizam I Batra A Gogos S
Full Access

INTRODUCTION. The Woodpecker pneumatic broaching system facilitates femoral preparation to achieve optimal primary fixation of the stem in direct anterior hip replacement using a standard operating table. The high-frequency axial impulses of the device reduce excess bone tension, intraoperative femoral fractures and overall operating time. The Woodpecker device provides uniformity and enhanced control while broaching, optimizing cortical contact between the femur and implant and thereby maximizing prosthetic axial stability and longevity. This study aims to describe a single surgeon's experience using the Woodpecker pneumatic broaching system in 649 cases of direct anterior approach (DAA) total hip arthroplasties to determine the device's safety and efficacy. METHODOLOGY. All consecutive patients undergoing elective anterior bikini total hip arthroplasties (THA) performed by a single surgeon between July 2013 and June 2018 were included. Patients undergoing a THA with the use of the Woodpecker device through a different surgical approach, revision THA or arthroplasties for a fractured neck of femur were excluded (n=219). The pneumatic device was used for broaching the femoral canal in all cases. Pre-operative and post-operative Harris Hip Scores (HHS) and post-operative radiographs were analyzed to identify femoral fractures and femoral component positioning at 6 weeks, 6 months and 12 months post-operative. Any intra-operative or post-operative surgical complications and component survivorship until most recent follow up were recorded in the clinical notes. RESULTS. A total of 649 patients (L THA=317, R THA=328 and bilateral=2) with a mean age of 69 (range 46–91yrs) and mean BMI of 28.3 (range = 18.4–44.0) underwent a DAA THA using a Woodpecker device were included in the study. Of these patients, 521 (80%) underwent uncemented and 128 (20%) underwent cemented femoral components. The time taken to broach the femur using Woodpecker broaching this system averaged 2.8 minutes (1.4 to 7.5 minutes) in both cemented and uncemented cases. In 91% of cases the templated broach size was achieved with the remaining 9% within +/− 1 size of the planned template. Radiographic analysis revealed 67.3% of the stems placed in 0–1.82 degrees of varus and 32.7% placed in 0–1.4 degrees of valgus. Average HHS were 24.4 pre-operatively, with drastic improvements shown at 6 weeks (80.95), 6 months (91.91) and 12 months (94.18) after surgery. Intraoperative femoral fractures occurred in three patients (0.4%) during trial reduction, a further three patients had periprosthetic post-operative fractures (0.4%) from falls, two patients had stem subsidence (0.3%) and a further two patients had wound infections (0.3%). At the most recent follow up, the survivorship of the acetabular component was 99.7% and the femoral component was 99.1%, with mean follow up of 2.9 years (0.5 to 5 years). No intraoperative or post-operative complications could be directly attributed to the Woodpecker broaching system. CONCLUSION. The pneumatic Woodpecker device is a safe and effective alternative tool in minimally invasive direct anterior hip replacement surgery for femoral broaching performed on a standard operating table. The skill and experience of the surgeon must be taken into consideration when utilizing new surgical devices


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 52 - 52
1 Feb 2020
Sadhwani S Picache D Janssen D de Ruiter L Rankin K Briscoe A Verdonschot N Shah A
Full Access

Introduction. Polyetheretherketone (PEEK) has been proposed as an implant material for femoral total knee arthroplasty (TKA) components. Potential clinical advantages of PEEK over standard cobalt chrome alloys include modulus of elasticity and subsequently reduced stress shielding potentially eliminating osteolysis, thermal conduction properties allowing for a more natural soft tissue environment, and reduced weight enabling quicker quadriceps recovery. Manufacturing advantages include reduced manufacturing and sterilization time, lower cost, and improved quality control. Currently, no PEEK TKA implants exist on the market. Therefore, evaluation of mechanical properties in a pre-clinical phase is required to minimize patient risk. The objectives of this study include evaluation of implant fixation and determination of the potential for reduced stress shielding using the PEEK femoral TKA component. Methods and Materials. Experimental and computational analysis was performed to evaluate the biomechanical response of the femoral component (Freedom Knee, Maxx Orthopedics Inc., Plymouth Meeting, PA; Figure 1). Fixation strength of CoCr and PEEK components was evaluated in pull-off tests of cemented femoral components on cellular polyurethane foam blocks (Sawbones, Vashon Island, WA). Subsequent testing investigated the cemented fixation using cadaveric distal femurs. The reconstructions were subjected to 500,000 cycles of the peak load occurring during a standardized gait cycle (ISO 14243-1). The change from CoCr to PEEK on implant fixation was studied through computational analysis of stress distributions in the cement, implant, and the cement-implant interface. Reconstructions were analyzed when subjected to standardized gait and demanding squat loads. To investigate potentially reduced stress shielding when using a PEEK component, paired cadaveric femurs were used to measure local bone strains using digital image correlation (DIC). First, standardized gait load was applied, then the left and right femurs were implanted with CoCr and PEEK components, respectively, and subjected to the same load. To verify the validity of the computational methodology, the intact and reconstructed femurs were replicated in FEA models, based on CT scans. Results. The cyclic load phase of the pull-off experiments revealed minimal migration for both CoCr and PEEK components, although after construct sectioning, debonding at the implant-cement interface was observed for the PEEK implants. During pull-off from Sawbones the ultimate failure load of the PEEK and CoCr components averaged 2552N and 3814N respectively. FEA simulations indicated that under more physiological loading, such as walking or squatting, the PEEK component had no increased risk of loss of fixation when compared to the CoCr component. Finally, the DIC experiments and FEA simulations confirmed closer resemblance of pre-operative strain distribution using the PEEK component. Discussion. The biomechanical consequences of changing implant material from CoCr to PEEK on implant fixation was studied using experimental and computational testing of cemented reconstructions. The results indicate that, although changes occur in implant fixation, the PEEK component had a fixation strength comparable to CoCr. The advantage of long term bone preservation, as the more compliant PEEK implant is able to better replicate the physiological loads occurring in the intact femur, may reduce stress shielding around the distal femur, a common clinical cause of TKA failure. For any figures or tables, please contact the authors directly