Advertisement for orthosearch.org.uk
Results 1 - 20 of 299
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 23 - 23
19 Aug 2024
Sionek A Bąbik B Czubak J
Full Access

Spasticity used to be considered a contraindication for total hip replacement (THR) procedures. Due to the development of implants as well as surgical skills, THR became an option for the treatment of painful dislocation of the hip joint in patients with spastic plegia. The aim of this study was an evaluation of mid-term results of THR in spastic CP adolescent patients with painful hips with hip joint subluxation or dislocation. In 2014–2022, 18 pts (19 hips) with CP aged 16 to 20 years underwent THR in our department. The mean follow-up was 4 years (range: 1 – 9 years). Results were evaluated using the Gross Motor Function Scale, VAS scale in accordance with the Ashworth scale, types of implants used (dual mobility cup and not dual mobility cup), and radiological assessment (Crowe scale). Complications have been thoroughly analyzed. In 10 pts there has been an improvement in the GMFSC scale average from 1 to 2 points observed after the surgery. All pts have improved in the VAS scale average of 8 points (from 10 to 7). According to the Crowe scale repositioning of preoperative dislocation to primary acetabulum was achieved in all cases. Complications occurred in 4 cases: dislocations of 2 THR with dual mobility cup and 2 THR with non-dual mobility cup requiring revision surgery with good final result. No statistical significance was noted according to the type of cup (Mann-Whitney U Test). The most important risk factor for complications is severe spasticity. We believe, that CP pts with painful hips should be treated using THR. We didn't observe any significant differences between the types of implants. These findings may serve as a basis for the prediction of outcomes of THR treatment in this specific group of pts. Level of evidence: Case-control or retrospective comparative study-Level III


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 13 - 13
19 Aug 2024
DeBenedetti A Weintraub MT Valle CJD Jacobs JJ Nam D
Full Access

The purpose of this randomized controlled trial was to evaluate serum metal levels in patients undergoing total hip arthroplasty (THA) with a conventional compared to a modular dual-mobility bearing. Patients undergoing primary THA for osteoarthritis were randomized to receive either a modular dual-mobility or conventional polyethylene bearing. All patients received the same titanium acetabular and femoral component and a ceramic femoral head. Serum metal levels were drawn pre-operatively then annually for a minimum of two years postoperatively. An a priori power analysis determined that 40 patients (20 per cohort) were needed to identify a clinically relevant difference in serum cobalt of 0.35 ng/ml (ppb) at 90% power. Forty-six patients were randomized to a modular dual-mobility (n=25) or conventional bearing (n=21) with 40 at a minimum follow-up of two years. No differences in serum cobalt (mean 0.14 ppb [range, 0.075–0.29] vs. 0.20 ppb [range, 0.075–0.57], p=0.39) or chromium levels (mean 0.14 ppb [range, 0.05–0.50] vs. 0.12 ppb [range, 0.05–0.35], p=0.65) were identified between the modular dual-mobility and conventional cohorts, respectively. There was no statistically significant difference in serum Co or Cr at two years postoperatively in subjects implanted with a ceramic head and this particular dual mobility bearing in comparison to a ceramic head and a conventional acetabular component. While modest expected elevations in serum Co and Cr were observed in the dual mobility group, in no case did the Co level exceed the laboratory reference range nor the threshold of one part per billion that has been associated with adverse local tissue reactions to mechanically-assisted crevice corrosion


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 43 - 43
19 Aug 2024
Lustig S Batailler C
Full Access

The stem design in total hip arthroplasty (THA) is constantly evolving. The impact of the collar on the risk of periprosthetic fracture remains controversial. This study aimed to determine whether adding a collar to the femoral stem impacts the early periprosthetic fracture risk within 90 days of surgery. This retrospective study included 1,623 patients who underwent primary total hip arthroplasty in a single orthopedic department between January 2010 and December 2020. The inclusion criteria were uncemented stem with or without a collar, in a primary intention, without previous hip surgery with a similar “corail like” design. The assessed data were demographic characteristics (age, gender, number of obese (BMI > 30)), single or dual mobility, the surgical approach, the early complication, particularly the periprosthetic femoral fractures. Of the 1,623 patients, 1,380 received a collared stem (85%), and 243 received a collarless stem (15%). A multivariate analysis was performed to determine the collar's effect on the risk of early periprosthetic fracture (<90 days). Nine (0.55%) early periprosthetic fractures were identified in the whole cohort. There were four fractures (1.65%) in the collarless stem group and five fractures (0.36%) in the collared stem group (p=0,005). One patient required revision surgery in the collared stem group, while two patients required revision surgery in the collarless stem group. The multinomial logistic regression model indicated a statistically significant lower (p<0.05) risk of early periprosthetic fracture within 90 days of surgery in the collared stems group. No other risk factor for early periprosthetic fractures has been identified. Using collared stems in cementless THA protects early periprosthetic femoral fractures within 90 days of surgery


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 14 - 14
19 Aug 2024
Shimmin A
Full Access

Dislocation is still one of the more common reasons for revision of THR.Registry and large institutional data has demonstrated the effectiveness of Dual Mobility articulations in reducing revision for dislocation after THR. There is little data about whether the use of dual mobility is associated with a comprised clinical functional outcome. This study aimed to ascertain whether the use of Dual Mobility articulations (DM cups) comes within a compromise to the functional of the THR procedure as measured by the Hip disability and Osteoarthritis Outcome Score (HOOS). Utilising a retrospective design, patients were grouped into those with DM cups with 12 PROMs (Cohort 1) or a large data base of all THR procedures also with a complete set of 12 month PROMs (Cohort 2). The 2 groups were matched for age and gender through propensity score matching. The comparison focused on five domains of the HOOS: Pain, Symptoms, Activities of Daily Living (ADL), Sports and Recreation, and Quality of Life (QOL) at 6- and 12-months post-operation. 12 month PROM data suggested a convergence in scores for several domains, no uniform superiority of one articulation type over the other was found across all domains. These results suggest that both DM cup and standard articulations can effectively improve patient-reported outcomes in THR surgeries, but there are variations in recovery within each cohort that are potentially influenced by factors beyond the articulation type. This study contributes to the ongoing dialogue on optimising prosthetic selection to enhance recovery trajectories and quality of life for THR patients, emphasising the critical role of evidence-based decision-making in orthopaedic surgery


Dislocations have impact on quality of life, but it is difficult to quantify this impact for each patient. The Quality-of-Life Time Trade-Off assesses the percentage of a patient's remaining life that the patient would be willing to trade for perfect health [1]. This technique has been used for non-unions [2], but never proposed for dislocation.

154 patients (with 3 recurrent dislocations) undergoing revision were asked to choose between living with their associated dislocation risk or trading a portion of their life expectancy for a period of perfect health without dislocation, thus determining their Quality-of-Life score. This score may range from 0.1 (willing to trade nine years among 10) to 1.0 (unwilling to trade any years). Additionally, patients were assessed on their willingness to trade implant survival time for a reduced risk of dislocation, considering various implant options that might offer lower (but not necessary) survival time before revision than the theoretical best (for the surgeon) “standard” implant, thus determining a “Survival Implant Quality” score.

Patients diagnosed with 3 hip dislocations have a low health-related quality of life. The score of our “dislocation” cohort was average 0.77 with patients willing to trade average 23% of remaining lifespan for perfect health (range 48% to 12%). This score is below that (0.88) of illnesses type-I diabetes mellitus [3] and just higher than tibial non-union (0.68) score [2]. The mean “Survival Implant Quality” score of our recurrent dislocation cohort was 0.71 (range 0.59 to 0.78) which means that patients accept to trade average 3 years (range 2 to 4 years) among 10 theoretical years of survival of the implant.

Hip dislocation has a devastating impact that can be quantified for each patient when discussing revision and choice of implants for instability.

For references, please contact the author directly.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 6 - 6
19 Aug 2024
Lausmann C Luck S Beil FT Citak M Gehrke T
Full Access

Mechanical failure due to dislocation, fracture and acetabular wear as well as persistence of infection are the main complications associated with the use of hip spacers in the treatment of periprosthetic joint infections (PJI). We have developed a novel, custom-made spacer as part of two-stage septic hip replacement and present the two- to five-year results after reimplantation. We prospectively examined a total of 73 patients over our study period in whom our new spacer technique was used. The technique includes a dual mobility inlay and a cemented straight stem in combination with antibiotic-loaded PMMA bone cement which allows full weight bearing meanwhile the interim period. The follow-up ranged between 24 and 60 months after reimplantation as second stage of a two-stage approach. The patients were contacted as part of the follow-up using a questionnaire concerning reoperation, reinfection as well as hip function by using the Harris Hip Score. 72 patients (98,6%) could be reimplanted, one patient is still using the spacer prothesis for 45 months because of excellent functional results with a Harris Hip Score of 95, nevertheless reimplantation is planned. The reinfection rate was less than 7% after reimplantation. The dislocation rate was 5%, and in total there was an overall complication rate of less than 10%. The Harris Hip Score was significantly improved. The ENDO spacer surgical technique is a promising option in the treatment of periprosthetic joint infections (PJI) for two-stage septic exchange with a low dislocation rate and good infection control after reimplantation. In addition, it enables early mobilization with the possibility of full weight-bearing in the interval between spacer implantation and reimplantation


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 66 - 66
19 Aug 2024
Terhune EB Sutter EG Balkissoon R Pallante GD Specht L Leikin JB Kwon YM Lewallen DG Gerlinger TL Jacobs JJ
Full Access

Ceramic-on-ceramic (CoC) articulations in total hip arthroplasty (THA) have low wear, but the unique risk of fracture. After revision for CoC fracture, ceramic third bodies can lead to runaway wear of cobalt chrome (CoCr) causing extremely elevated blood cobalt. We present five cases of ceramic liner fractures revised to a CoCr head associated with the rapid development of severe cobalt toxicity. We identified 5 cases of fractured CoC THA treated with revision to CoCr on highly cross-linked polyethylene (HXLPE) – three to conventional bearings and two to modular dual mobility bearings (CoCr acetabular liner, CoCr femoral head, and HXLPE). Mean follow up was 2.5 years after CoCr/HXLPE re-revision. Symptoms of cobalt toxicity occurred at average 9.5 months after revision for ceramic fracture (range 6–12). All patients developed vision and hearing loss, balance difficulties, and peripheral neuropathy. Several had cardiomyopathy, endocrinopathy, and local skin discoloration. Two reported hip pain. Re-revision for cobalt toxicity occurred at an average of 22 months (range 10–36) after revision for ceramic fracture. Average serum cobalt level at re-revision was 991 μg/L (range 734–1302, normal <1 μg/L). All CoCr heads exhibited massive wear with asphericity; deep tissues exhibited prominent metallosis. Treatment consisted of debridement and revision to a ceramic head with HXLPE. Serum cobalt improved to an average of 25 μg/L at final follow up. All patients reported partial improvement in vision and hearing; peripheral neuropathy and balance did not recover. Systemic cobalt toxicity is a rare but devastating complication of ceramic fracture in THA treated with cobalt-alloy bearings. Cobalt alloy bearings should be avoided in this setting. The diagnosis of systemic cobalt toxicity requires a high index of suspicion and was typically delayed following systemic symptoms. Debridement and revision to a ceramic-on-HXLPE leads to improvement but not resolution of cobalt toxicity complications


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 57 - 57
19 Aug 2024
Jones SA Davies O
Full Access

Dislocation following revision THA remains a leading cause of failure. Integrity of the abductor muscles is a major contributor to stability. Large diameter heads (LDH), Dual Mobility (DM) and Constrained Acetabular Liners (CAL) are enhanced stability options but the indication for these choices remains unclear. We assessed an algorithm based on Gluteus Medius (GM) deficiency to determine bearing selection. Default choice with no GM damage was a LDH. GM deficiency with posterior muscle intact received DM and CAL for GM complete deficiency with loss of posterior muscle. Consecutive revision THA series followed to determine dislocation, all-cause re-revision and Oxford Hip Score (OHS). 311 revision THA with mean age 70 years (32–95). At a mean follow-up of 4.8 years overall dislocation rate 4.1% (95%CI 2.4–7.0) and survivorship free of re-revision 94.2% (95%CI 96.3–91.0). Outcomes:. Group 1 - LDH (36 & 40mm) n=164 / 4 dislocations / 7 re-revisions. Group 2 - DM n=73 / 3 dislocations / 4 re-revisions. Group 3 - CAL n=58 / 5 dislocations / 7 re-revisions. Group 4 - Other (28 & 32mm) n=16 / 1 dislocation / no re-revisions. Mean pre-op OHS: 19.6 (2–47) and mean post-op OHS: 33.9 (4–48). Kaplan-Meier analysis at 60 months dislocation-free survival was 96.1% (95% CI: 93.0–97.8). There was no difference between survival distributions comparing bearing choice (p=0.46). Decision making tools to guide selection are limited and in addition soft tissue deficiency has been poorly defined. The posterior vertical fibres of GM have the greatest lateral stabiliser effect on the hip. The algorithm we have used clearly defined indication & implant selection. We believe our outcomes support the use of an enhanced stability bearing selection algorithm


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 15 - 15
19 Aug 2024
Argenson J Peuchot H Simmons EH Fabre-Aubrespy M Jacquet C Flecher X
Full Access

Dislocation after Total Hip Arthroplasty (THA) is a frequent cause of revision and patients with intrinsic risk factors have been identified. The use of dual mobility (DM) cup has shown great efficiency in preventing dislocation, with questions regarding selective or absolute use. The aim of this study was to compare the outcome of single mobility THA (SM-THA) and DM-THA, when used for selected patients. This retrospective continuous cohort study evaluated 490 patients of whom 275 received SM-THA and 215 received DM-THA. There were 304 primary osteoarthritis (62%), 121 femoral neck fractures (24%) and 65 other indications (14%). The surgical approach was anterior (AA) in 79% and posterior (PA) in 21% of cases. In the DM-THA group, 189 patients (87%) presented at least one dislocation risk factor compared to 128 patients (46%) in the SM-THA group. The primary outcome was revision for all causes, with or without implant removal. Secondary outcomes included length of hospital stay. There was no difference in all cause revision at two years follow up with 9 procedures (3.2%) in SM-THA group and 11 in DM-THA group (5.1%) (p=0.3). There were 3 dislocations in SM-THA group (3 AA) and 3 in DM-THA group (2 PA and 1 AA) (p=0.4). The length of stay was significantly longer in DM-THA group with 7 days (2–12) compared to 4 days (1–7) in SM-THA group (p=0.001). SM-THA and DM-THA are two complementary devices in the management of patients requiring primary THA. SM-THA is a safe option for patients without dislocation risk factors, especially when using AA. The identification of such factors is important to select patients requiring DM-THA and provide reproducible outcomes in a University Hospital practice including various levels of surgeon experience


Bone & Joint Open
Vol. 5, Issue 6 | Pages 514 - 523
24 Jun 2024
Fishley W Nandra R Carluke I Partington PF Reed MR Kramer DJ Wilson MJ Hubble MJW Howell JR Whitehouse SL Petheram TG Kassam AM

Aims

In metal-on-metal (MoM) hip arthroplasties and resurfacings, mechanically induced corrosion can lead to elevated serum metal ions, a local inflammatory response, and formation of pseudotumours, ultimately requiring revision. The size and diametral clearance of anatomical (ADM) and modular (MDM) dual-mobility polyethylene bearings match those of Birmingham hip MoM components. If the acetabular component is satisfactorily positioned, well integrated into the bone, and has no surface damage, this presents the opportunity for revision with exchange of the metal head for ADM/MDM polyethylene bearings without removal of the acetabular component.

Methods

Between 2012 and 2020, across two centres, 94 patients underwent revision of Birmingham MoM hip arthroplasties or resurfacings. Mean age was 65.5 years (33 to 87). In 53 patients (56.4%), the acetabular component was retained and dual-mobility bearings were used (DM); in 41 (43.6%) the acetabulum was revised (AR). Patients underwent follow-up of minimum two-years (mean 4.6 (2.1 to 8.5) years).


Different techniques have been described to address massive bone loss of the acetabulum in revision hip surgery. aMace has gained popularity as it provides customization aiming to restore hip centre and provide good initial stability in cases of large non-contained defects. It takes into account quality of host bone. Its porous defect filling scaffold provides an excellent surface for osteointegration. Our aim was to assess the short and mid-term outcomes of patients who underwent revision surgery using aMace system. Ethical approval was obtained. A retrospective study included all patients who had aMace between June 2013 and October 2022 allowing for a minimum of 12-months follow-up. Patients’ demographics, indication, bone-loss severity, reconstruction details, re-operation, complications, mortality, pain and function were assessed. 52 cases were performed by 13 surgeons with median 51 months follow-up. Median age was 72.7 years. 86.5% were female. Average BMI was 25.3. Average ASA grade was 3. 65% were classified as Paprosky IIIB and 32% were IIIA. 73% were found to have poor bone quality on CT. Main indication for aMace was massive bone loss/discontinuity secondary to aseptic loosening in 88.5%. 77% underwent single-stage revision. 53.8% had 2 or more previous revisions. 71% underwent stem revision in the same setting. 77% received a dual mobility bearing. Re-operation rate was 5.7% for instability and femoral PPF. LLD was reported in 9.6%. Permanent Sciatic nerve palsy occurred in 3.8% of the cases. 30-days mortality was 1.9%. Statistically significant post-op improvements in pain and mobility were reported (p<0.001). None of the acetabular components have been revised. Our study shows satisfactory surgical outcomes with a relatively low complication rate and significant pain and mobility improvements in the early to mid-term stages. We recommend these costly cases to be done in highly specialist centres adopting MDT approach


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 15 - 15
2 May 2024
Williams S Smeeton M Isaac G Anderson J Wilcox R Board T Williams S
Full Access

Dual Mobility (DM) Total Hip Replacements (THRs), are becoming widely used but function in-vivo is not fully understood. The aim of this study was to compare the incidence of impingement of a modular dual mobility with that of a standard cup. A geometrical model of one subject's bony anatomy \[1\] was developed, a THR was implanted with the cup at a range of inclination and anteversion positions (Corail® stem, Pinnacle® cup (DePuy Synthes)). Two DM variants and one STD acetabular cup were modelled. Joint motions were taken from kinematic data of activities of daily living associated with dislocation \[2\] and walking. The occurrence of impingement was assessed for each component combination, orientation and activity. Implant-implant impingement can occur between the femoral neck and the metal or PE liner (DM or STD constructs respectively) or neck-PE mobile liner (DM only). The results comprise a colour coded matrix which sums the number of impingement events for each cup position and activity and for each implant variant. Neck-PE mobile liner impingement, occurred for both DM sizes, for all activities, and most cup placement positions indicating that the PE mobile liner is likely to move at the start of all activities including walking. For all constructs no placement positions avoided neck-metal (DM) or neck-PE liner (STD) impingementevents in all activities. The least number of events occurred at higher inclination and anteversion component positions. In addition to implant-implant impingement, some instances of bone-bone and implant-bone impingement were also observed. Consistent with DM philosophy, neck-PE mobile liner impingement and liner motion occurred for all activities including walking. Neck-liner impingement frequency was comparable between both DM sizes (metal liner) and a standard cup (PE liner)


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 32 - 32
2 May 2024
Yan A Yan A Hoggett L Helm A
Full Access

The increased torque required to dislocate dual mobility (DM) components may increase peri-prosthetic femoral fracture (PPF) risk. Current literature often relies on revision as an endpoint and may underestimate PPF. This study aims to review PPF rate, risks and treatment following primary DM implantation. Prospective cohort study of 549 patients following primary DM total hip arthroplasty (THA) between 2013 and 2021. Collected data included demographics, indication for surgery, cortical index and PPF. 549 patients were identified with primary DM THA. Mean age was 73 years (26–96). 446 (81.2%) patients had their index surgery following hip fracture. 18 patients (3.27%) sustained a PPF. Cumulative PPF rate was 1.5% at 1-year, 2.2% at 5-years and 3.27% overall. PPF was higher in patients undergoing surgery following hip fracture (4%) vs. other indications (1%). OR 4.04 (95% CI:0.53, 30.72), p=0.219. Mean cortical index was lower in patients with PPF 0.4 (95% CI:0.36, 0.45) compared to those without 0.46 (95% CI:0.45, 0.46) p=0.029. Treatment for PPF included 10 (55.6%) open reduction internal fixation (ORIF), 7 (38.9%) revision THA and 1 conservatively managed. PPF rate following DM use is higher in our cohort than published rates. Our rates are comparable to some papers when subgroup analysis of older patients and cemented taper slip stems are considered. PPF risk with DM may be increased in patients undergoing surgery after hip fracture or with a lower cortical index preoperatively. Over half of PPF were managed with ORIF and may mask PPF risk studies that report using revision as an endpoint


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 98 - 104
1 May 2024
Mallett KE Guarin Perez SF Taunton MJ Sierra RJ

Aims

Dual-mobility (DM) components are increasingly used to prevent and treat dislocation after total hip arthroplasty (THA). Intraprosthetic dissociation (IPD) is a rare complication of DM that is believed to have decreased with contemporary implants. This study aimed to report incidence, treatment, and outcomes of contemporary DM IPD.

Methods

A total of 1,453 DM components were implanted at a single academic institution between January 2010 and December 2021: 695 in primary and 758 in revision THA. Of these, 49 presented with a dislocation of the large DM head and five presented with an IPD. At the time of closed reduction of the large DM dislocation, six additional IPDs occurred. The mean age was 64 years (SD 9.6), 54.5% were female (n = 6), and mean follow-up was 4.2 years (SD 1.8). Of the 11 IPDs, seven had a history of instability, five had abductor insufficiency, four had prior lumbar fusion, and two were conversions for failed fracture management.


Bone & Joint 360
Vol. 13, Issue 2 | Pages 17 - 20
1 Apr 2024

The April 2024 Hip & Pelvis Roundup360 looks at: Impaction bone grafting for femoral revision hip arthroplasty with the Exeter stem; Effect of preoperative corticosteroids on postoperative glucose control in total joint replacement; Tranexamic acid in patients with a history of venous thromboembolism; Bisphosphonate use may be associated with an increased risk of periprosthetic hip fracture; A balanced approach: exploring the impact of surgical techniques on hip arthroplasty outcomes; A leap forward in hip arthroplasty: dual-mobility bearings reduce groin pain; A new perspective on complications: the link between blood glucose and joint infection risks.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 81 - 88
1 Mar 2024
Lustig S Cotte M Foissey C Asirvatham RD Servien E Batailler C

Aims

The benefit of a dual-mobility acetabular component (DMC) for primary total hip arthroplasties (THAs) is controversial. This study aimed to compare the dislocation and complication rates when using a DMC compared to single-mobility (SM) acetabular component in primary elective THA using data collected at a single centre, and compare the revision rates and survival outcomes in these two groups.

Methods

Between 2010 and 2019, 2,075 primary THAs using either a cementless DM or SM acetabular component were included. Indications for DMC were patients aged older than 70 years or with high risk of dislocation. All other patients received a SM acetabular component. Exclusion criteria were cemented implants, patients treated for femoral neck fracture, and follow-up of less than one year. In total, 1,940 THAs were analyzed: 1,149 DMC (59.2%) and 791 SM (40.8%). The mean age was 73 years (SD 9.2) in the DMC group and 57 years (SD 12) in the SM group. Complications and revisions have been analyzed retrospectively.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 89 - 96
1 Mar 2024
Heckmann ND Chung BC Liu KC Chen XT Lovro LR Kistler NM White E Christ AB Longjohn DB Oakes DA Lieberman JR

Aims

Modular dual-mobility (DM) articulations are increasingly used during total hip arthroplasty (THA). However, concerns remain regarding the metal liner modularity. This study aims to correlate metal artifact reduction sequence (MARS)-MRI abnormalities with serum metal ion levels in patients with DM articulations.

Methods

A total of 45 patients (50 hips) with a modular DM articulation were included with mean follow-up of 3.7 years (SD 1.2). Enrolled patients with an asymptomatic, primary THA and DM articulation with over two years’ follow-up underwent MARS-MRI. Each patient had serum cobalt, chromium, and titanium levels drawn. Patient satisfaction, Oxford Hip Score, and Forgotten Joint Score-12 (FJS-12) were collected. Each MARS-MRI was independently reviewed by fellowship-trained musculoskeletal radiologists blinded to serum ion levels.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_3 | Pages 11 - 11
23 Jan 2024
Raj S Magan A Jones SA
Full Access

Dual mobility (DM) is an established bearing option in Total Hip Arthroplasty (THA). The traditional mono-block DM designs have limited ability for additional fixation, whereas the modular DM designs allow additional screw fixation but limit internal diameter and have the potential to generate metal debris. We report the early results of a CoCrMo alloy mono-block implant manufactured by additive technology with a highly porous ingrowth surface to enhance primary fixation and osseointegration. Prospective follow-up of the Duplex. TM. implant first inserted in March 2016 enrolled into Beyond Compliance (BC). Primary outcome measure was all-cause revision and secondary outcomes dislocation, peri-prosthetic fracture (PPF) and Oxford Hip Score (OHS). Patients were risk stratified and all considered to be high risk for instability. Complications were identified via hospital records, clinical coding linkage using national database and via BC website. 159 implants in 154 patients with a mean age 74.0 years and a maximum F/U of 7 years. Survivorship for all-cause revision 99.4% (95% CI 96.2–99.8). One femoral only revision. Mean gain in OHS 27.4. Dislocation rate 0.6% with a single event. Patients with a cemented Polished taper stem (PTS) had a Type B PPF rate of 2.1% requiring revision/fixation. Compared to conventional THA this cohort was significantly older (74.0 vs 68.3 years), more co-morbidity (ASA 3 46.5% vs 14.4%) and more non-OA indications (32.4% vs 8.5%). Every patient had at least one risk factor for falling and >50% of cohort had 4 or more risk factors using NICE tool. We believe our results demonstrate that risk stratification successfully aids implant selection to prevent dislocation in high-risk patients. This novel design has provided excellent early results in a challenging cohort where individuals are very different to the “average” THA patient. NJR data on DM has reported an increase in revision for PPF. A “perfect storm” maybe created using DM in high-risk falls risk population. This re-enforces the need to consider all patient and implant factors when deciding bearing selection


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 98 - 98
2 Jan 2024
Mehta S Goel A Mahajan U Reddy N Bhaskar D
Full Access

Dislocation post THA confers a higher risk of re-dislocation (Kotwal et al, 2009). The dual mobility (DM) cup design (1974) was aimed at improving the stability by increasing the femoral head to neck ratio (Cuthbert et al., 2019) combining the ideas of low friction arthroplasty with increased jump distance associated with a big head arthroplasty. Understand the dislocation rates, rates of aseptic loosening, infection rate and revision rates between the 2 types of constructs to provide current and up-to date evidence. Medline, pubmed, embase and Cochrane databases were used based on PRISMA guidelines. RevMan software was used for the meta-analysis. Studies (English literature) which used DM construct with atleast 6 months follow-up used as intervention and non DM construct as control were included. 2 independent reviewers conducted the review with a third reviewer in case of difference in opinion regarding eligibility. Primary outcome was dislocation rate and secondary outcome was rate of revision. 564 articles identified out of which 44 articles were screened for full texts and eventually 4 systematic review articles found eligible for the study. Thus, study became a review of systematic reviews. From the 4 systematic reviews, another 35 studies were identified for data extraction and 13 papers were used for meta-analysis. Systematic reviews evaluated, projected an average follow up of 6-8 years with significantly lower dislocation rates for DM cups. The total number of patients undergoing DM cup primary THA were 30,559 with an average age 71 years while the control group consisted of 218,834 patients with an average age of 69 years. DM group had lower rate of dislocation (p < 0.00001), total lower rate of cup revision (p < 0.00001, higher incidence of fracture (p>0.05). DM THA is a viable alternative for conventional THA. The long-term results of DM cups in primary THA need to be further evaluated using high quality prospective studies and RCTs


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 1 - 1
17 Nov 2023
Mehta S Goel A Mahajan U Reddy R Bhaskar D
Full Access

Abstract. Introduction. Dislocation post THA confers a higher risk of re-dislocation (Kotwal et al, 2009). The dual mobility (DM) cup design (1974) was aimed at improving the stability by increasing the femoral head to neck ratio (Cuthbert et al., 2019) combining the ideas of low friction arthroplasty with increased jump distance associated with a big head arthroplasty. Aims. Understand the dislocation rates, rates of aseptic loosening, infection rate and revision rates between the 2 types of constructs to provide current and up-to date evidence. Methods. Medline, pubmed, embase and Cochrane databases were used based on PRISMA guidelines. RevMan software was used for the meta-analysis. Studies (English literature) which used DM construct with atleast 6 months follow-up used as intervention and non DM construct as control were included. 2 independent reviewers conducted the review with a third reviewer in case of difference in opinion regarding eligibility. Primary outcome was dislocation rate and secondary outcome was rate of revision. Results. 564 articles identified out of which 44 articles were screened for full texts and eventually 4 systematic review articles found eligible for the study. Thus, study became a review of systematic reviews. From the 4 systematic reviews, another 35 studies were identified for data extraction and 13 papers were used for meta-analysis. Systematic reviews evaluated, projected an average follow up of 6–8 years with significantly lower dislocation rates for DM cups. The total number of patients undergoing DM cup primary THA were 30,559 with an average age 71 years while the control group consisted of 218,834 patients with an average age of 69 years. DM group had lower rate of dislocation (p < 0.00001), total lower rate of cup revision (p < 0.00001, higher incidence of fracture (p>0.05). Conclusion. DM THA is a viable alternative for conventional THA. The long-term results of DM cups in primary THA need to be further evaluated using high quality prospective studies and RCTs. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project