Advertisement for orthosearch.org.uk
Results 1 - 20 of 123
Results per page:
Bone & Joint Open
Vol. 5, Issue 11 | Pages 999 - 1003
7 Nov 2024
Tan SHS Pei Y Chan CX Pang KC Lim AKS Hui JH Ning B

Aims

Congenital pseudarthrosis of the tibia (CPT) has traditionally been a difficult condition to treat, with high complication rates, including nonunion, refractures, malalignment, and leg length discrepancy. Surgical approaches to treatment of CPT include intramedullary rodding, external fixation, combined intramedullary rodding and external fixation, vascularized fibular graft, and most recently cross-union. The current study aims to compare the outcomes and complication rates of cross-union versus other surgical approaches as an index surgery for the management of CPT. Our hypothesis was that a good index surgery for CPT achieves union and minimizes complications such as refractures and limb length discrepancy.

Methods

A multicentre study was conducted involving two institutions in Singapore and China. All patients with CPT who were surgically managed between January 2009 and December 2021 were included. The patients were divided based on their index surgery. Group 1 included patients who underwent excision of hamartoma, cross-union of the tibia and fibula, autogenic iliac bone grafting, and internal fixation for their index surgery. Group 2 included patients who underwent all other surgical procedures for their index surgery, including excision of hamartoma, intramedullary rodding, and/or external fixation, without cross-union of the tibia and fibula. Comparisons of the rates of union, refracture, limb length discrepancy, reoperations, and other complications were performed between the two groups.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 8 - 8
23 Apr 2024
Senan R Linkogel W Marwan Y Staniland T Sharma H
Full Access

Introduction. Knee arthrodesis is a useful limb salvage technique to maintain function in patients with complex and infected total knee arthroplasties (TKA). There are a number of commonly used external fixators, but no consensus on which of these are optimal. The aim of this study was to synthesise the current literature to guide clinical decision making and improve patient outcomes. We systematically review the literature to compare outcomes of external fixators in arthrodesis following infected TKA. Materials & Methods. A systematic review of the literature of primary research articles investigating the use of external fixators for knee arthrodesis after an infected TKA was conducted. Relevant articles were identified with a search strategy on online databases (EMBASE and Medline) and reviewed by two independent reviewers. Clinical outcome measures were independently extracted by two reviewers which included union rate, infection eradication rate, complication rate, time to fusion, and time in frame. Results. Circular frames were more likely to result in union compared to biplanar (OR 1.40 p=0.456) and monoplanar frames (OR 2.28 p=0.018). Infection recurrence was least likely in those treated by circular frames when compared to monoplanar (OR 0.12 p=0.005) and biplanar external fixators (0.41 P=0.331). Complication rates were highest in the circular fixator group, followed by the monoplanar fixator group and biplanar fixator group at 34%, 31% and 11% respectively. Conclusions. Analysis of the available literature suggests higher union and infection eradication rates with circular frames over the other two fixation methods despite a higher complication rate. There is a paucity in the literature and therefore, no firm conclusions can be drawn. Further research investigating the variations and biomechanical properties between different external fixation methods for knee arthrodesis is necessary. Further clarity in reporting and pooled data would be useful for future analysis


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 5 - 5
23 Apr 2024
Sain B Sidharthan S Naique S
Full Access

Introduction. Treatment of non-union in open tibial fractures Gustilo-Anderson(GA)-3A/3B fractures remains a challenging problem. Most of these can be dealt using treatment methods that requires excision of the non-union followed by bone grafting, masquelet technique, or acute shortening. Circular fixators with closed distraction or bone transport also remains a useful option. However, sometimes due to patient specific factors these cannot be used. Recently antibiotic loaded bone substitutes have been increasingly used for repairing infected non-unions. They provide local antibiotic delivery, fill dead space, and act as a bone conductive implant, which is resorted at the end of a few months. We aimed to assess the outcome of percutaneous injection of bone substitute while treating non-union of complex open tibial fractures. Materials & Methods. Three cases of clinical and radiological stiff tibial non-union requiring further intervention were identified from our major trauma open fracture database. Two GA-3B cases, treated with a circular frame developed fracture-related-infection(FRI) manifesting as local cellulitis, loosened infected wires/pins with raised blood-markers, and one case of GA-3A treated with an intramedullary nail. At the time of removal of metalwork/frame, informed consent was obtained and Cerament-G. TM. (bone-substitute with gentamicin) was percutaneously injected through a small cortical window using a bone biopsy(Jamshedi needle). All patients were allowed to weight bear as tolerated in a well-fitting air-cast boot and using crutches. They were followed up at 6 weekly intervals with clinical assessment of their symptoms and radiographs. Fracture union was assessed using serial radiographs with healing defined as filling of fracture gap, bridging callus and clinical assessment including return to full painless weight bearing. Results. Follow-up at 6 months showed all fractures had healed with no defect or gaps with evidence of new trabecular bone and significant resorption of Cerament-G. TM. at final follow-up. There was no evidence of residual infection with restoration of normal limb function. Fractures with no internal fixation showed a mild deformity that had developed during the course of the healing, presumed due to mild collapse in the absence of fixation. These were less than 10 degrees in sagittal and coronal planes and were clinically felt to be insignificant by the patients. Conclusions. Cerament-G's unique combination of high dose antibiotics and hydroxy apatite matrix provided by calcium sulphate might help provide an osteoconductive environment to allow these stiff non-unions to heal. The matrix appears to provide a scaffold-like structure that allows new bone in-growth with local release of antibiotics helping reduce deep-seated infections. The final deformation at fracture site underlines the need for fixation- and it is very unlikely that this technique will work in mobile nonunions. Whilst similar fractures may heal without the use of bone substitute injections, the speed of healing in presence of significant fracture gap suggests the use of these bone substitutes did help in our cases. Further studies with a larger cohort, including RCTs, to evaluate the effectiveness of this technique compared to other methods are needed


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 11 - 11
23 Apr 2024
Lineham B Faraj A Hammet F Barron E Hadland Y Moulder E Muir R Sharma H
Full Access

Introduction. Intra articular distal tibia fractures can lead to post-traumatic osteoarthritis. Joint distraction has shown promise in elective cases. However, its application in acute fractures remains unexplored. This pilot study aims to fill this knowledge gap by investigating the benefits of joint distraction in acute fractures. Materials & Methods. We undertook a restrospective cohort study comprising patients with intra-articular distal tibia and pilon fractures treated with a circular ring fixator (CRF) at a single center. Prospective data collection included radiological assessments, Patient-Reported Outcome Measures (PROM), necessity for additional procedures, and Kellgren and Lawrence grade (KL) for osteoarthritis (OA). 137 patients were included in the study, 30 in the distraction group and 107 in the non-distraction group. There was no significant difference between the groups. Results. Mean follow-up was 3.73 years. There was no significant difference between the groups in overall complications or need for further procedures. There was no significant difference in progression of KL between the groups (1.81 vs 2.0, p=0.38) mean follow up 1.90 years. PROM data was available for 44 patients (6 distraction, 38 non-distraction) with a mean follow-up of 1.71 years. There was no significant difference in EQ5D (p=0.32) and C Olerud-H Molander scores (p=0.17). Conclusions. This pilot study suggests that joint distraction is safe in the acute setting. However, the study's impact is constrained by a relatively small patient cohort and a short-term follow-up period. Future investigations should prioritise longer-term follow-ups and involve a larger patient population to more comprehensively evaluate the potential benefits of joint distraction in acute fractures


Bone & Joint 360
Vol. 13, Issue 1 | Pages 7 - 8
1 Feb 2024
Jamal B Round J Qureshi A


Bone & Joint Open
Vol. 4, Issue 8 | Pages 643 - 651
24 Aug 2023
Langit MB Tay KS Al-Omar HK Barlow G Bates J Chuo CB Muir R Sharma H

Aims

The standard of wide tumour-like resection for chronic osteomyelitis (COM) has been challenged recently by adequate debridement. This paper reviews the evolution of surgical debridement for long bone COM, and presents the outcome of adequate debridement in a tertiary bone infection unit.

Methods

We analyzed the retrospective record review from 2014 to 2020 of patients with long bone COM. All were managed by multidisciplinary infection team (MDT) protocol. Adequate debridement was employed for all cases, and no case of wide resection was included.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 7 - 7
1 Jun 2023
Harris PC Lacey S Steward A Sertori M Homan J
Full Access

Introduction. The various problems that are managed with circular external fixation (e.g. deformity, complex fractures) also typically require serial plain x-ray imaging. One of the challenges here is that the relatively radio-opaque components of the circular external fixator (e.g. the rings) can obscure the view of the area of interest (e.g. osteotomy site, fracture site). In this presentation we describe how the geometry of the x-ray beam affects the produced image and how we can use knowledge of this to our advantage. Whilst this can be applied to any long bone, we have focused on the tibia, given that it's the most common long bone that is treated by circular external fixation. Materials & Methods. In the first part of the presentation we describe the known attributes (geometry) of the x-ray beam and postulate what effect it would have when we x-ray a long bone that is surrounded by a circular external fixator. In the second part we demonstrate this in practice using a tibia and a 3 ring circular external fixator. Differing x-ray beam orientations are used to demonstrate both how the geometry of the beam affects the produced image and how we can use this to our advantage to better visualise part of the bone. Results. The practical part of the study confirmed the theoretical part. Conclusions. Knowledge of the beam geometry can be used to minimise the obscuring nature of the circular fixator. This technique is simple and can be easily taught to the radiographer. It is a useful adjunct for the limb reconstruction surgeon


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 3 - 3
1 Jun 2023
Williams L Stamps G Peak H Singh S Narayan B Graham S Peterson N
Full Access

Introduction

External fixation (EF) devices are commonly used in the management of complex skeletal trauma, as well as in elective limb reconstruction surgery for the management of congenital and acquired pathology. The subsequent removal of an EF is commonly performed under a general anaesthetic in an operating theatre. This practice is resource intensive and limits the amount of operating theatre time available for other surgical cases. We aimed to assess the use of regional anaesthesia as an alternative method of analgesia to facilitate EF removal in an outpatient setting.

Materials & Methods

This prospective case series evaluated the first 20 consecutive cases of EF removal in the outpatient clinic between 10/06/22 to 16/09/22. Regional anaesthesia using ultrasound-guided blockade of peripheral nerves was administered using 1% lidocaine due to its rapid onset and short half-life. Patients were assessed for additional analgesia requirement, asked to evaluate their experience and perceived pain using the Visual Analogue Scale (VAS).


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 8 - 8
1 Jun 2023
Harris PC Lacey S Perdomo A Ramsay G
Full Access

Introduction. The vast majority of orthopaedic surgeons use C-arm fluoroscopy in the operating theatre when building a circular external fixator. In the absence of previous research in this area, we hypothesised that the surgeon who builds a circular external fixator is exposed to a greater amount of radiation purely as a result of the presence of the metallic fixator in the x-ray beam. The aim of our study therefore was to investigate how the presence of a circular external fixator affects the radiation dose to the surgeon and the surgical assistant. Materials & Methods. A simulated environment was created using a radiolucent operating table, an acrylic lower limb phantom (below knee segment), various configurations of metalic circular external fixation, and a standard size C-arm image intensifier. The variables investigated were 1. the amount of metal in the beam 2. the orientation of the beam (PA vertical vs lateral) 3. the horizonal distance of the person from the beam (surgeon vs assistant) and 4. the vertical distance of the various body parts from the beam (e.g. thyroid, groin). In terms of radiation dose, we recorded two things : 1. the dose produced by the image intensifier 2. the dose rate at standardised positions in the operating theatre. The latter was done using a solid-state survey sensor. These positions represented both where the surgeon and surgical assistant typically stand plus the heights of their various body regions relative to the operating table. Results. The effect of the presence of the circular external fixator : all frame constructs tested resulted in a statistically significant greater radiation dose both produced by the image intensifier and received by the surgical team. The effect of the beam orientation : the PA (vertical) orientation resulted in a statistically significant greater radiation dose for the surgeon than did the lateral orientation, but made no difference for the assistant. The effect of horizontal distance from the beam : unsurprisingly, the surgeon (who was closer to the beam) received a statistically significant greater radiation dose than the assistant. The effect of vertical distance from the beam : for the surgeon, the dose received was highest at the level of the phantom leg / frame, whilst for the assistant there was no statistically significant difference for any level. Conclusions. To our knowledge, this is the first study investigating the radiation dose rate to the orthopaedic surgeon when building a circular external fixator. We found that the surgeon does indeed receive a ‘double whammy’ because the image intensifier puts out a greater amount of radiation plus the metalic frame scatters more of the x-ray beam. Whilst the amounts are relatively small, we think that it's important to quantify doses that orthopaedic surgeons receive to ensure optimal radiation practices


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 49 - 49
1 Jun 2023
Thompson E Shamoon S Qureshi A
Full Access

Introduction. Circular external fixators are fundamental to lower limb reconstruction, primarily in situations with a high risk of infection such as open fractures. During the Covid-19 pandemic, use of circular frames in our unit decreased, following departmental approval, due to resource management and in keeping with BOA guidelines as we opted to “consider alternative techniques for patients who require soft tissue reconstruction to avoid multiple operations”. These alternatives included the use of internal fixation (plate osteosynthesis and intramedullary nailing) as a measure to reduce the number of hospital attendances for patients and to conserve resources. This change in practice has continued in part following the pandemic with the increased use of internal fixation in cases previously deemed unsuitable for such techniques. We present our experience of this treatment strategy in the management of complex lower limb injuries, focusing on outcomes and consider the lessons learnt. Materials & Methods. Data of patients with complex lower limb injuries treated before, during and after the pandemic were collected from our in-house trauma database, theatre records and follow up clinics. The rationale for choosing other techniques over a circular frame, the type of alternative technique used, the cost of such alternatives, the need for soft tissue reconstruction, time to recovery, complications and amputation rates were compared among groups. Results. These data suggest comparable outcomes between circular frames and alternative techniques can be achieved. A notable reduction in the number of circular frames applied during the review period was observed. Furthermore, frame fixation was associated with more frequent outpatient review and the associated implications for resource management. Conclusions. Conclusion: The Covid-19 pandemic has posed great challenges to the Trauma and Orthopaedic community, forcing us to be flexible by adopting alternative treatment methods to traditional circular external fixation. These alternatives have proven feasible and potentially more cost effective, prompting their adoption in the post pandemic era. However, this change of practice is not without potential consequences and continued investigation is warranted


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 136 - 136
11 Apr 2023
Glatt V Woloszyk A Agarwal A
Full Access

Our previous rat study demonstrated an ex vivo-created “Biomimetic Hematoma” (BH) that mimics the intrinsic structural properties of normal fracture hematoma, consistently and efficiently enhanced the healing of large bone defects at extremely low doses of rhBMP-2 (0.33 μg). The aim of this study was to determine if an extremely low dose of rhBMP-2 delivered within BH can efficiently heal large bone defects in goats. Goat 2.5 cm tibial defects were stabilized with circular fixators, and divided into groups (n=2-3): 2.1 mg rhBMP-2 delivered on an absorbable collagen sponge (ACS); 52.5 μg rhBMP-2 delivered within BH; and an empty group. BH was created using autologous blood with a mixture of calcium and thrombin at specific concentrations. Healing was monitored with X-rays. After 8 weeks, femurs were assessed using microCT. Using 2.1 mg on ACS was sufficient to heal 2.5 cm bone defects. Empty defects resulted in a nonunion after 8 weeks. Radiographic evaluation showed earlier and more robust callus formation with 97.5 % (52.5 μg) less of rhBMP-2 delivered within the BH, and all tibias were fully bridged at 3 weeks. The bone mineral density was significantly higher in defects treated with BH than with ACS. Defects in the BH group had smaller amounts of intramedullary and cortical trabeculation compared to the ACS group, indicating advanced remodeling. The results confirm that the delivery of rhBMP-2 within the BH was much more efficient than on an ACS. Not only did the large bone defects heal consistently with a 40x lower dose of rhBMP-2, but the quality of the defect regeneration was also superior in the BH group. These findings should significantly influence how rhBMP-2 is delivered clinically to maximize the regenerative capacity of bone healing while minimizing the dose required, thereby reducing the risk of adverse effects


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 29 - 29
1 Dec 2022
Pedrini F Salmaso L Mori F Sassu P Innocenti M
Full Access

Open limb fractures are typically due to a high energy trauma. Several recent studied have showed treatment's superiority when a multidisciplinary approach is applied. World Health Organization reports that isolate limb traumas have an incidence rate of 11.5/100.000, causing high costs in terms of hospitalization and patient disability. A lack of experience in soft tissue management in orthopaedics and traumatology seems to be the determining factor in the clinical worsening of complex cases. The therapeutic possibilities offered by microsurgery currently permit simultaneous reconstruction of multiple tissues including vessels and nerves, reducing the rate of amputations, recovery time and preventing postoperative complications. Several scoring systems to assess complex limb traumas exist, among them: NISSSA, MESS, AO and Gustilo Anderson. In 2010, a further scoring system was introduced to focus open fractures of all locations: OTA-OFC. Rather than using a single composite score, the OTA-OFC comprises five components grades (skin, arterial, muscle, bone loss and contamination), each rated from mild to severe. The International Consensus Meeting of 2018 on musculoskeletal infections in orthopaedic surgery identified the OTA-OFC score as an efficient catalogue system with interobserver agreement that is comparable or superior to the Gustilo-Anderson classification. OTA-OFC predicts outcomes such as the need for adjuvant treatments or the likelihood of early amputation. An orthoplastic approach reconstruction must pay adequate attention to bone and soft tissue infections management. Concerning bone management: there is little to no difference in terms of infection rates for Gustilo-Anderson types I–II treated by reamed intramedullary nail, circular external fixator, or unreamed intramedullary nail. In Gustilo-Anderson IIIA-B fractures, circular external fixation appears to provide the lowest infection rates when compared to all other fixation methods. Different technique can be used for the reconstruction of bone and soft tissue defects based on each clinical scenario. Open fracture management with fasciocutaneous or muscle flaps shows comparable outcomes in terms of bone healing, soft tissue coverage, acute infection and chronic osteomyelitis prevention. The type of flap should be tailored based on the type of the defect, bone or soft tissue, location, extension and depth of the defect, size of the osseous gap, fracture type, and orthopaedic implantation. Local flaps should be considered in low energy trauma, when skin and soft tissue is not traumatized. In high energy fractures with bone exposure, muscle flaps may offer a more reliable reconstruction with fewer flap failures and lower reoperation rates. On exposed fractures several studies report precise timing for a proper reconstruction. Hence, timing of soft tissue coverage is a critical for length of in-hospital stay and most of the early postoperative complications and outcomes. Early coverage has been associated with higher union rates and lower complications and infection rates compared to those reconstructed after 5-7 days. Furthermore, early reconstruction improves flap survival and reduces surgical complexity, as microsurgical free flap procedures become more challenging with a delay due to an increased pro-thrombotic environment, tissue edema and the increasingly friable vessels. Only those patients presenting to facilities with an actual dedicated orthoplastic trauma service are likely to receive definitive treatment of a severe open fracture with tissue loss within the established parameters of good practice. We conclude that the surgeon's experience appears to be the decisive element in the orthoplastic approach, although reconstructive algorithms may assist in decisional and planification of surgery


Bone & Joint 360
Vol. 11, Issue 5 | Pages 6 - 8
1 Oct 2022
Jamal B Calder P


Bone & Joint 360
Vol. 11, Issue 5 | Pages 20 - 23
1 Oct 2022


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 703 - 708
1 Jun 2022
Najefi A Zaidi R Chan O Hester T Kavarthapu V

Aims

Surgical reconstruction of deformed Charcot feet carries a high risk of nonunion, metalwork failure, and deformity recurrence. The primary aim of this study was to identify the factors contributing to these complications following hindfoot Charcot reconstructions.

Methods

We retrospectively analyzed patients who underwent hindfoot Charcot reconstruction with an intramedullary nail between January 2007 and December 2019 in our unit. Patient demographic details, comorbidities, weightbearing status, and postoperative complications were noted. Metalwork breakage, nonunion, deformity recurrence, concurrent midfoot reconstruction, and the measurements related to intramedullary nail were also recorded.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 27 - 27
1 Apr 2022
Harrison WD Fortuin F Joubert E Durand-Hill M Ferreira N
Full Access

Introduction. Temporary spanning fixation aims to provide bony stability whilst allowing access and resuscitation of traumatised soft-tissues. Conventional monolateral fixators are prone to half-pin morbidity in feet, variation in construct stability and limited weight-bearing potential. This study compares traditional delta-frame fixators to a circular trauma frame; a virtual tibial ring block spanned onto a fine-wire foot ring fixation. Materials and Methods. The two cohorts were compared for demographics and fracture patterns. The quality of initial reduction and the maintenance of reduction until definitive surgery was assessed by two authors and categorised into four domains. Secondary measures included fixator costs, time to definitive surgery and complications. Results. Fifty-six delta-frames and 48 circular fixators were statistically matched for demographics and fracture pattern. Good or excellent initial reduction was achieved in 51 (91%) delta-frames and 48 (100%) circular fixators (p=0.022). Loss of reduction was observed in 15 (27%) delta-frames and 3 (6%) circular fixators (p<0.001). Post-fixator dislocation occurred in five (9%) delta-frames and one (2%) circular fixator (p=0.147). Duration in spanned fixation was equivalent (11.5 and 11.6 days respectively, p=0.211). Three (5%) delta-frames and 12 (25%) circular fixators were used as definitive fixation. The mean hardware cost was £3,116 for delta-frames and £2,712 for circular fixators. Conclusions. Temporary circular fixation offers statistically superior intra-operative reduction and maintenance of reduction, facilitates weight-bearing and provides more opportunity as the definitive fixation. Circular fixation hardware proved to be less expensive and protected against further scheduled and unscheduled operations


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 50 - 50
1 Apr 2022
Ferreira N Arkell C Fortuin F Saini A
Full Access

Introduction. The accuracy of hexapod circular external fixator deformity correction is contingent on the precision of radiographic analysis during the planning stage. The aim of this study was to compare the SMART TSF (Smith and Nephew, Memphis, Tennessee) in-suite radiographic analysis methods with the traditional manual deformity analysis methods in terms of accuracy of correction. Materials and Methods. Sawbones models were used to simulate two commonly encountered clinical scenarios. Traditional manual radiographic analysis and digital SMART TSF analysis methods were used to correct the simulated deformities. Results. The final outcomes of all six analysis methods across both simulated scenarios were satisfactory. Any differences in residual deformity between the analysis methods are unlikely to be clinically relevant. All three SMART TSF digital analyses were faster to complete than manual radiographic analyses. Conclusions. With experience and a good understanding of the software, manual radiographic analysis can be extremely accurate and remains the gold standard for deformity analysis. In-suite SMART TSF radiographic analysis is fast and accurate to within clinically relevant parameters. Surgeons can with confidence trust the SMART TSF software to provide analysis and corrections that are clinically acceptable


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1611 - 1618
1 Oct 2021
Kavarthapu V Budair B

Aims

In our unit, we adopt a two-stage surgical reconstruction approach using internal fixation for the management of infected Charcot foot deformity. We evaluate our experience with this functional limb salvage method.

Methods

We conducted a retrospective analysis of prospectively collected data of all patients with infected Charcot foot deformity who underwent two-stage reconstruction with internal fixation between July 2011 and November 2019, with a minimum of 12 months’ follow-up.


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1160 - 1167
1 Jun 2021
Smith JRA Fox CE Wright TC Khan U Clarke AM Monsell FP

Aims

Open tibial fractures are limb-threatening injuries. While limb loss is rare in children, deep infection and nonunion rates of up to 15% and 8% are reported, respectively. We manage these injuries in a similar manner to those in adults, with a combined orthoplastic approach, often involving the use of vascularised free flaps. We report the orthopaedic and plastic surgical outcomes of a consecutive series of patients over a five-year period, which includes the largest cohort of free flaps for trauma in children to date.

Methods

Data were extracted from medical records and databases for patients with an open tibial fracture aged < 16 years who presented between 1 May 2014 and 30 April 2019. Patients who were transferred from elsewhere were excluded, yielding 44 open fractures in 43 patients, with a minimum follow-up of one year. Management was reviewed from the time of injury to discharge. Primary outcome measures were the rate of deep infection, time to union, and the Modified Enneking score.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 44 - 44
1 May 2021
Zenios M Oyadiji T Zamini-Farahani A
Full Access

Introduction. In my paediatric Orthopaedic practice I use Kirchner wires for the fixation of the TSF on bone. I noted a significant percentage of wire loosening during the post-operative period. The aim of this project was to establish the effectiveness of the wire clamping mechanism and find ways to reduce the incidence of wire loosening when using the TSF. Materials and Methods. In the first instance wire slippage was measured intra-operatively after the tensioner was removed using an intra-operative professional camera. Following this study mechanical tests were performed in the lab measuring the pull out properties of Kirchner wires using different bolts and different torque levels in order to tighten the wire on the fixator. Results. Our clinical study confirmed wire slippage intra-operatively immediately after the tensioner was removed. Wire slippage after the tensioner was removed was found to vary from 0.01 mm to 0.51 mm (mean 0.19 mm). Our mechanical tests showed that the ideal torque for tightening the wire on the frame using a bolt was around 15 N.m. A comparison between cannulated and slotted bolts suggested that cannulated bolts are more effective as a clamping mechanism. A comparison between aluminium made Taylor Spatial frame rings and stainless steel made Ilizarov rings suggested that the Taylor Spatial frame rings are more effective as part of a clamping mechanism. Conclusions. It is important that clinicians routinely measure the torque they use to clamp wires on circular external fixators. Clinicians and manufacturers are informed that the type of bolt used is important in maintaining wire tension. Manufacturers should design the ideal bolt which effectively grips the wire without the risk of fracture. The Ilizarov frame clamping mechanism can be effectively used with the Taylor Spatial frame