Advertisement for orthosearch.org.uk
Results 1 - 20 of 575
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 68 - 68
22 Nov 2024
Mannala G Labat B Ladam G Pascal T Walter N Szymski D Riool M Alt V Rupp M
Full Access

Aim. Orthopedic implants play a tremendous role in fixing bone damages due to aging as well as fractures. However, these implants tend to get colonized by bacteria on the surface, leading to infections and subsequently prevention of healing and osteointegration. Recently, Roupie et al. showed that a nisin layer-by-layer based coating applied on biomaterials has both osteogenic and antibacterial properties. The Galleria mellonella larva is a well-known insect infection model that has been used to test the virulence of bacterial and fungal strains as well as for the high throughput screening of antimicrobial compounds against infections. Recently, we have developed an insect infection model with G. mellonella larvae to study implant-associated biofilm infections using Kirschner (K)-wires as implant material. Here, we would like to test the antibacterial capacity of nisin layer-by-layer based coatings on K-wires against Staphylococcus aureus in the G. mellonella larva implant infection model. Method. Prior to the implantation procedure, G. mellonella larvae are maintained at room temperature on wheat germ in an incubator. The larvae received bare titanium K-wires (uncoated), or either control-coated or nisin-coated K-wires. After one hour, the larvae were injected with 5×10. 5. S. aureus bacteria per larva (i.e., hematogenous implant infection model). Next, the larvae were incubated at 37. o. C in an incubator and the survival of the larvae was monitored for five days. Moreover, the number of bacteria on the implant surface and in the surrounding tissue was determined after 24h of incubation. Further, scanning electron microscopy (SEM) analyses were performed to study the effect of nisin on biofilm formation. Results. The larvae receiving the nisin-coated K-wires showed significantly higher survival rates compared to uncoated titanium K-wires, although not when compared to control-coated K-wires. A more than 1-log reduction in number of bacteria on the implant surface and in the surrounding tissue was observed in larvae receiving the nisin-coated K-wires, when compared to uncoated titanium K-wires SEM analysis showed reduced colonization of the bacteria nisin-coated K-wires compared to the controls. Conclusions. In conclusion, the antimicrobial nisin layer-by-layer based coating applied on titanium surfaces is able to prevent implant-related S. aureus biofilm infection in G. mellonella and is a promising antimicrobial strategy to prevent implant-related infections


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 13 - 13
22 Nov 2024
McNally M Dietz M Piuzzi N Chen A Parvizi J Stolarski E Pelt C Rodriguez-Quintana D Trautner B Dobbins D
Full Access

Aim. Antimicrobial peptides occur naturally in our intrinsic immune system. PLG0206 is a novel, engineered, 24-amino acid peptide which has broad-spectrum antimicrobial activity, including in biofilm and against multi-drug resistant pathogens (1,2). This is the first clinical study to evaluate the safety and tolerability of PLG0206 when administered via an irrigation solution in patients with periprosthetic joint infections (PJI) following total knee arthroplasty (TKA) during debridement, antibiotics, and implant retention (DAIR). Secondary objectives were to evaluate pharmacokinetics (PK), biomarkers and initial clinical efficacy at one year post-DAIR procedure. Method. This prospective, multicenter, open-label, interventional study assessed two dose levels of PLG0206. Fourteen patients underwent revision for PJI after TKA. At the end of debridement, they received a single intra-articular irrigation of PLG0206 into the wound cavity lasting 15 minutes at concentrations of 3 mg/mL (n=7) or 10 mg/mL (n=7). Patients received post-operative care and intravenous/oral antimicrobial therapy as per their institutional guidelines. Patients were monitored for safety and signs of relapse or persistent infection for 12 months post study drug administration and PK and blood biomarkers were assessed. Results. All patients completed their final study assessment at Day 365. Over the 1-year follow-up, only one recurrence (7%) was noted at Day 169 in the low-dose cohort. Following dosing, nine patients (64.3%) had limited systemic exposure; maximum plasma concentration occurred 1-hour post-administration and declined rapidly to undetectable levels by 24 hours following treatment in all patients. The incidence of drug related treatment-emergent adverse events (TEAEs) was low. Two patients, both in the higher dose cohort, experienced a transient drug related TEAE; one of hypertransaminasaemia and one of neuralgia. Both events were moderate in severity and resolved within two weeks of onset. Conclusions. A single 15-minute irrigation of PLG0206 into the wound cavity of patients undergoing a DAIR procedure for PJI following TKA, is safe and well tolerated by patients. This new antimicrobial peptide offers a promising therapeutic option in musculoskeletal infection. The initial clinical efficacy is encouraging but now needs to be investigated in a much larger clinical trial


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 20 - 20
22 Nov 2024
Elder A Wijendra A Hotchen A Wangrangsimakul T Young B Barrett L Ferguson J
Full Access

Aim. An instrumented blood culture system automatically flags when growth within the culture medium has been detected (‘work in progress’), and subsequently when the organism has been identified. We explore using this data to switch patients to oral therapy within 72 hours post-surgery, reducing costs and improving antimicrobial stewardship. Method. This retrospective review focused on clinically significant culture-positive bone and joint infections over a 5-month period in 2022. Two cohorts were defined as either having positive intraoperative microbiology at <72 hours or at ≥72 hours. Results. 150 patients were included. 133/150(88%) exhibited microbial growth <72hours. Of these, 98/133(74%) had all organisms identified <72-hours, and 34/133(26%) had additional organisms ≥72 hours. 19/151(12%) patients had their first positive cultures ≥72hrs from sampling. The most common isolates identified within 72 hours were S. aureus(30%), Enterobacteriaceae (26%), and Coagulase-negative Staphylococcus (CoNS)(19%). If no growth was observed by 48 hours, there was a 69.6% probability that subsequent growth wouldn't occur; this probability increases to 81.9% by 72 hours, 88.7% by 96 hours, 91.0% by 120 hours, and 95.0% by 144 hours (see figure 1). The most common isolates identified ≥72 hours were CoNS(28%), Cutibacterium acnes(16%) and S. aureus(12%). Assessing oral antibiotic regimes for isolates identified after 72 hours demonstrated that linezolid would cover isolates from 96% of patients, tetracyclines 92% of patients, clindamycin 85% of patients, and ciprofloxacin and rifampicin would cover 80% of patients. Vancomycin and meropenem, our standard empirical therapy, gave the best cover at 96% of patients. Conclusions. This study suggests there is sufficient microbiological information at 72 hours for most patients to allow transition to a targeted regimen. If there has been no detection of growth when using an instrumented blood culture system by 72 hours, it is likely that there will be no growth. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 56 - 56
22 Nov 2024
Hanssen J Gademan M Wouthuyzen-Bakker M Davis JS Dewar D Manning L Campbell D van Prehn J Miller A van der Wal R van der Linden E Cortes-Penfield N Soriano A De Boer MG Scheper H
Full Access

Aim. Suppressive antimicrobial therapy (SAT) is used worldwide for patients with a prosthetic joint infection (PJI but clear definitions or guidelines regarding the indications, antimicrobial strategy or treatment duration are currently lacking in the literature. The aim of this study was to identify the global differences in the clinical practice of SAT for PJI. Method. An online survey was designed to investigate the current opinion on indication and treatment goals, preferred antimicrobial drugs, dosing and treatment duration and follow-up of patients with PJI on suppression. The survey was distributed using e-mail lists of several international bone and joint infection societies and study groups. Recipients were asked to share the survey with colleagues who were not a member of one of the societies but who were involved in PJI care. Results. The questionnaire was fully completed by 330 physicians from 43 different countries on six continents (Europe, n=134, 41%; Oceania n=112, 34%; North America, n=51, 16%; other, n=33, 10%; total response rate 14%). Antimicrobial treatment for PJI was discussed in a multidisciplinary team in Europe (90%), Oceania (42%) and North America (12%). In six of eight (75%) different clinical scenarios, respondents from North America would most often place a patient on SAT. In seven of eight (88%) scenarios, SAT was started least often by European respondents. The presence of a fistula was considered a contra-indication for suppression by 74 respondents (22%). First choices of SAT for staphylococcal PJI were: oral cephalosporins (39%) and tetracyclines (31%) in North America; anti-staphylococcal penicillins (55%) and oral cephalosporins (24%) in Oceania; tetracyclines (27%) and anti-staphylococcal penicillins (22%) in Europe. For streptococcal PJI, most clinicians preferred penicillins (91% in Oceania, 67% in Europe, and 53% in North America). Preferred SAT for gram negative PJI was: fluoroquinolones and a penicillin/betalactamase inhibitor in North America (26% and 18%, respectively) and Oceania (23% and 27%, respectively); fluoroquinolones (31%) and Cotrimoxazole (28%) in Europe. The dosage of SAT was never lowered (n=126, 38%), standardly lowered for all antibiotics (n=79, 24%) or only lowered for specific antibiotics (n=125, 38%). SAT was prescribed for an indefinite duration (n=43, 13%), as fixed duration between six months and three years (n=104, 32%) or for an undetermined prespecified duration (n=154, 47%). Conclusions. Substantial variation in the practice of SAT for PJI exists between physicians worldwide and throughout the different continents. This reflects the paucity of data regarding the indication and treatment of PJI with SAT


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 44 - 44
22 Nov 2024
De Bleeckere A Neyt J Vandendriessche S Boelens J Coenye T
Full Access

Aim. Fast and accurate identification of pathogens causing periprosthetic joint infections (PJI) is essential to initiate effective antimicrobial treatment. Culture-based approaches frequently yield false negative results, despite clear signs of infection. This may be due to the use of general growth media, which do not mimic the conditions at site of infection. Possible alternative approaches include DNA-based techniques, the use of in vivo-like media and isothermal microcalorimetry (ITC). We developed a synthetic synovial fluid (SSF) medium that closely resembles the in vivo microenvironment and allows to grow and study PJI pathogens in physiologically relevant conditions. In this study we investigated whether the use of ITC in combination with the SSF medium can improve accuracy and time to detection in the context of PJI. Methods. In this study, 120 synovial fluid samples were included, aspirated from patients with clinical signs of PJI. For these samples microbiology data (obtained in the clinical microbiology lab using standard procedures) and next generation sequencing (NGS) data, were available. The samples were incubated in the SSF medium at different oxygen levels (21% O. 2. , 3% O. 2. and 0% O. 2. ) for 10 days. Every 24h, the presence of growth was checked. From positive samples, cultures were purified on Columbia blood agar and identified using MALDI-TOF. In parallel, heat produced by metabolically active microorganisms present in the samples was measured using ITC (calScreener, Symcel), (96h at 37°C, in SSF, BHI and thioglycolate). From the resulting thermograms the ‘time to activity’ could be derived. The accuracy and time to detection were compared between the different detection methods. Results. So far, seven samples were investigated. Using conventional culture-based techniques only 14.3% of the samples resulted in positive cultures, whereas NGS indicated the presence of microorganisms in 57.1% of the samples (with 3/7 samples being polymicrobial). Strikingly, 100% of the samples resulted in positive cultures after incubation in the SSF medium, with time to detection varying from 1 to 9 days. MALDI-TOF revealed all samples to be polymicrobial after cultivation in SSF, identifying organisms not detected by conventional techniques or NGS. For the samples investigated so far, signals obtained with ITC were low, probably reflecting the low microbial load in the first set of samples. Conclusion. These initial results highlight the potential of the SSF medium as an alternative culture medium to detect microorganisms in PJI context. Further studies with additional samples are ongoing; in addition, the microcalorimetry workflow is being optimized


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 1 - 1
22 Nov 2024
McNally M Frank F Hotchen A Valand P Stubbs D Ferguson J
Full Access

Aim. This is the first study to directly compare the clinical outcome of debridement, antimicrobials and implant retention (DAIR) with stabilization using new internal fixation after debridement, for patients with Fracture-related Infection (FRI). Method. Consecutive patients with FRI Consensus confirmed FRI had single-stage surgery with tissue sampling, debridement, stabilization, antimicrobial therapy and skin closure. All cases had FRIs which were unhealed at surgery. When existing implants were stable, the implant was retained but loose implants or fractures with poor reduction had implant removal and refixation with new implants. All patients had the same empiric and definitive antibiotics, the same diagnostic criteria and outcome assessment at least one year after surgery. Failure was defined as infection recurrence, reoperation or lack of fracture consolidation at one year. Results. Seventy-one patients were studied (40 DAIRs and 31 new implants, including 10 exchange nails). The two groups were well matched for age, duration of infection, BACH complexity, microbiology, bone involved and need for flap coverage. Ten patients (13.7%) died before the endpoint. Mortality was similar in both groups (DAIR 14.1% vs New Metalware 12.9%; p=0.801) but DAIR of IM nails had a higher mortality at 40% (p=0.011). Sixty-one patients were followed-up for a mean of 3.32 years (1.04-9.43). Infection was eradicated in 23/34 (67.6%) DAIR patients and 24/27 (88.9%) with new metalware (p=0.049). Overall rates of infection-free union were similar in both groups (58.8% vs 77.8%; p=0.117). DAIR of plates had significantly fewer infection-free unions compared to removal and implantation of new plates (DAIR 57.1% vs NM 91.7%; p=0.033). Conclusion. Implantation of new metalware had better eradication of infection and a strong trend towards better union rates. Treating FRI with retained or new metalware had a substantial mortality (13.7%). Choosing DAIR did not reduce this mortality and these patients more often required further surgery to treat residual infection and secure union


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 28 - 28
22 Nov 2024
Boyce S Nichol T Smith T Le Maitre C
Full Access

Aim. Periprosthetic joint infections follow 1-3% of arthroplasty surgeries, with the biofilm nature of these infections presenting a significant treatment challenge. 1. Prevention strategies include antibiotic-loaded bone cement; however, increases in cementless procedures means there is an urgent need for alternative local antimicrobial delivery methods. 2. A novel, ultrathin, silica-based sol-gel technology is evaluated in this research as an anti-infective coating for orthopaedic prosthetic devices, providing local antibiotic release following surgery. Method. Reduction in clinically relevant microbial activity and biofilm reduction by antimicrobial sol-gel coatings, containing a selection of antibiotics, were assessed via disc diffusion and microdilution culture assays using the Calgary biofilm device. 3. Proliferation, morphology, collagen, and calcium production by primary bovine osteoblasts cultured upon antibiotic sol-gel surfaces were examined, and cytotoxicity evaluated using Alamar blue staining and lactate dehydrogenase assays. Concentrations of silica, calcium and phosphorus compounds within the cell layer cultured on sol-gel coatings and concentrations eluted into media, were quantified using ICP-OES. Furthermore, cellular phenotype was assessed using alkaline phosphatase activity with time in culture. Results. Low antibiotic concentrations within sol-gel had an inhibitory effect on clinically relevant biofilm growth, for example 0.8 mg ml. -1. tobramycin inhibited clinically isolated S. aureus (MRSA) growth with an 8-log reduction in viable colony forming units. There was no significant difference in metabolic activity between untreated and sol-gel exposed primary bovine osteoblasts in elution-based assays. Reduction (2-fold) in metabolic activity in direct contact assays after 48 hours exposure was likely to be due to increased osteoinduction, whereas no impact upon cell proliferation were observed (p=0.92 at 14 days culture). The morphology of primary osteoblasts was unaffected by culture on sol-gel coatings and collagen production was maintained. Calcium containing nodule production within bovine osteoblastic cells was increased 16-fold after 14 days culture upon sol-gel. Conclusions. The ultrathin sol-gel coating showed low cytotoxicity, strong biofilm reducing activity and antimicrobial activity, which was comparable to antibiotics alone, demonstrating that sol-gel delivery of antibiotics could provide local antimicrobial effects to inhibit PJI growth without the need for bone cement. Future work will develop and evaluate sol-gel performance in an ex vivo explant bone infection model which will reduce the need for animal experimentation


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 3 - 3
22 Nov 2024
Samuel BJ Horbert V Jin Z Brauer DS Matziolis G
Full Access

Aim

Biomaterial-associated infections (BAI) present a formidable clinical challenge. Bioactive glasses (BG) have proven highly successful in diverse clinical applications, especially in dentistry and orthopaedics. In this study, we aimed to determine the effect of three commonly used BG composition and particle sizes on cell and bacterial attachment and growth. Our focus is on understanding the changes in pH and osmotic pressure in the surrounding environment during glass degradation.

Method

First, three different melt-derived glasses were characterized by analyzing particle size and glass network structure using Raman and NMR. The different glasses were then tested in vitro by seeding 4x 104 cells/well (SaOS Cell line) in a 48 well plate. After a pre-incubation period of 72 hours, the different BGs and particle sizes were added to the cells and the pH value, ion release and live/dead staining was measured every hour. The effect of BG against bacteria (S. epidermidis) was analyzed after 24 and 72 hours of treatment by using XTT viability assay and CFU counting by plating out the treated aliquot agar to estimate the viable bacteria cells.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 9 - 9
22 Nov 2024
Wali R Miller C Harrison C Stafford G Hatton P
Full Access

Introduction. In specific conditions, infection may lead to bone loss and is difficult to treat. 1. Current clinical approaches rely on the introduction of antibiotics. While these may be effective, there are concerns regarding the rise of antimicrobial resistance. There is therefore interest in the development of antimicrobial bone graft substitutes for dental and trauma surgery. Aim & Objectives. The incorporation of zinc into biomaterials has been shown to confer broad spectrum antimicrobial activity, but this has not yet been applied to the development of a commercial bone graft substitute. The aim of this research was therefore to prepare and characterise a series of zinc-substituted nanoscale hydroxyapatite (nHA) materials, including evaluation of antimicrobial activity. Method. Zinc (Zn) substituted nHA materials were prepared (0, 5, 10, 15 & 20 mol.% Zn) using a wet chemical precipitation method with a rapid mixing. (2). The reaction was carried out using zinc hydroxide at pH 10. The suspension formed was washed and dried into both powder & paste forms. The resultant powders were characterized using transmission electron microscopy (TEM) and X-ray diffraction (XRD). The antimicrobial activity was evaluated against Staphylococcus aureus (S8650 strain - isolated from an osteomyelitis case), by two techniques. The Miles and Misra method was applied to determine the number of colony-forming units (CFUs) in bacterial suspensions incubated with pastes. Secondly, a biofilm initialization method was used to evaluate the capacity of the materials to prevent biofilm formation. One-way analysis of variance (ANOVA) was used for the statistical analysis and results with p-value < 0.05 were considered statistically significant. Results. XRD indicated the formation of pure hydroxyapatite with up to 10 mol.% Zn without any side products. However, when Zn was increased to 15 & 20 mol %, zinc oxide (ZnO) peaks were detected. The TEM showed nanoscale needle-like particles when Zn was increased compared to nHA particles. Regarding the antibacterial activity, ZnHA pastes at all concentrations caused a significant reduction in bacterial CFUs in a dose-dependent manner (50, 100 & 200 mg). Additionally, even the lowest zinc substitution (5 mol.%) significantly reduced biofilm formation. Conclusion. The results demonstrated a novel method to produce a Zn-substituted nHA that showed antimicrobial activity against a pathogen isolated from a bone infection


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 24 - 24
22 Nov 2024
Veerman K Telgt D Rijnen W Donders R Kullberg BJ Wertheim H Goosen J
Full Access

Aim. Periprosthetic joint infection (PJI) is a severe complication after total joint arthroplasty. To prevent PJI, strict infection prevention measures are followed in combination with surgical antibiotic prophylaxis (SAP). To date, scientific reports concerning the optimal duration of SAP in revision arthroplasty are scarce. The aim of this multicenter open-label, randomized controlled trial in the Netherlands, is to investigate the superiority of 5 days (extended) versus a single dose of cefazolin to prevent PJI within the first year after revision arthroplasty of the hip and knee. Method. Included patients with an assumed aseptic hip or knee revision procedure received a single dose of 2 or 3 gram cefazolin preoperatively. Patients were randomly assigned in a 1:1 ratio to receive extended prophylaxis of cefazolin during 5 days postoperatively versus no prophylaxis after wound closure. Patients were excluded if evidence of PJI at revision. The primary endpoint was the incidence of PJI within one year after revision arthroplasty. PJI was defined according to the 2018 Philadelphia consensus criteria. With a sample size of 746 patients, an alpha of 5% and a power of 80%, superiority of the extended regimen would be shown if the lower boundary of the 95% confidence interval (CI) of the absolute between-group difference of the percentage of PJI is below −4%. Results. In total 751 patients were included for analysis: 379 in the single dose cefazolin group and 372 in the extended group. Within one year, PJI occurred in 2.6% (10/379) in the single dose group and 2.4% (9/372) in the extended group (risk difference, −0.2 percentage points; 95% CI, −2.5 to 2.0%), thus superiority was not shown. Adverse drug events were seen in 20 cases with extended and 7 cases with a single dose prophylaxis. Conclusions. Extended prophylaxis is not significantly superior to a single dose of cefazolin to prevent PJI within the first year after revision arthroplasty of the hip or knee. This is the first randomized controlled trail in which the duration of SAP in the selected group of patients undergoing revision arthroplasty was studied. Extending SAP after closure of the wound could increase the selection or induction of antimicrobial resistance, has an increased risk for adverse drug events, and is therefore not in line with the primary goal of antimicrobial stewardship, comprising optimizing clinical outcomes and ensuring cost-effective therapy while minimizing unintended consequences of antimicrobial use


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 8 - 8
22 Nov 2024
Arts C
Full Access

Introduction. Various biomaterials and bone graft substitute technologies for use in osteomyelitis treatment are currently used in clinal practice. They vary in mode of action (with or without antibiotics) and clinical application (one-stage or two-stage surgery). This systematic review aims to compare the clinical evidence of different synthetic antimicrobial bone graft substitutes and antibiotic-loaded carriers in eradicating infection and clinical outcome in patients with chronic osteomyelitis. Methods. Systematic review according to PRISMA statement on publications 2002-2023. MESH terms: osteomyelitis and bone substitutes. FREE terms: chronic osteomyelitis, bone infection. A standardized data extraction form was be used to extract data from the included papers. Results. Publications with increased methodological quality and clinical evidence for biomaterials in osteomyelitis treatment were published in the last decades. High 85-95% eradication rates of osteomyelitis were observed for various resorbable Ca-P and/or Ca-S biomaterials combined with antibiotics and S53P4 bioactive glass. Level of evidence varies significantly between products. Antibiotic pharmacokinetic release profiles vary between resorbable Ca-P and/or Ca-S biomaterials. Conclusion. Given the high 85-95% eradication rates of osteomyelitis by various resorbable Ca-P and/or Ca-S biomaterials combined with antibiotics and S53P4 bioactive glass, one-stage treatment is preferred. Surgeons should be aware of variations in mechanical properties and antibiotic pharmacokinetic release profiles between Ca-P and CA-s products. Mechanical, biological and antimicrobial properties of bioactive glass are formulation dependent. Currently, only S53P4 bioactive glass has proven antimicrobial properties. Based on this systematic review antibiotic loaded fleeces should be used with caution and restraint


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 66 - 66
22 Nov 2024
Ye Z van der Wildt B Vogely C Weinans H Poot A van der Wal B
Full Access

Aim. Prosthetic joint infections (PJI) remain a great challenge in orthopedic surgery with a high mortality rate. It is particularly complicated by biofilms and infections caused by Methicillin-resistant Staphylococcus aureus (MRSA). It concurrently shields bacteria from host immune responses and confers resistance to antibiotics. This study aims to investigate the efficacy of radioimmunotherapy as an innovative therapeutic modality to address the challenges posed by MRSA and its biofilm. Method. We induced specific monoclonal antibodies 4497-IgG1 as carriers, which target wall teichoic acids (WTA) existing on MRSA and its biofilm. Radionuclides actiniumr-225 (. 225. Ac, α-emitter) and lutetium-177 (. 177. Lu, β-emitter) were conjugated with mAbs using DOTA as chelator. Quality control was assessed using thin layer chromatography and immunoreactivity assays. . 225. Ac- and . 177. Lu-labelled 4497-IgG1 were employed to evaluate the susceptibility of MRSA and its biofilm to the radioimmunotherapy in vitro. Planktonic MRSA and biofilms, at concentrations of 10. 8. and 10. 7. CFU/mL, were incubated at 37°C for 60 minutes in PBS containing either . 225. Ac-mAb (0 - 14.8 kBq) or . 177. Lu-mAb (0 - 14.8 MBq). Radiolabelled dunituximab and free radionuclides serve as isotype-matched negative control. The bacterial viability and metabolic activity were subsequently quantified using CFU and XTT assays. Results. The radiochemical purity of the . 225. Ac-mAbs and . 177. Lu-mAbs complex were determined to be 95.4% and 96.16%. Immunoreactivity fractions of them were measured at 81.8% and 80.8%. . 225. Ac-mAbs and . 177. Lu-mAbs exhibited significant and dose-dependent antimicrobial effects on both planktonic MRSA and biofilm. . 225. Ac- and . 177. Lu-4497IgG1 at doses of 7.4 kBq and 7.4 MBq resulted in more than 4-log reduction in bacterial counts. In biofilms, 2-log reduction at the highest . 225. Ac radioactivity of 14,8kBq. The . 177. Lu complex showed a strong dose-dependent effect, with a reduction of up to 4-log. The XTT assay confirmed these findings, showing a decrease in metabolic activity corresponding to a decrease in bacterial counts, and a slight increase in metabolic activity at the lower dose. Conclusions. Our study demonstrates the efficacy of . 225. Ac and . 177. Lu-labelled 4497-IgG1 antibodies in mediating dose-dependent bactericidal effects against planktonic MRSA and biofilms in vitro. This indicates that radioimmunotherapy could be a potential targeted therapeutic strategy against MRSA and its biofilm. Further research in preclinical and clinical settings is warranted to validate and refine these findings on biofilm-associated implant infections


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 19 - 19
22 Nov 2024
Hanssen J Veerman K Van der Jagt O Somford M Lammers J Poolman R Peters E Visser J Bos K Verhagen R Vehmeijer S Zijlstra W Nolte P Wouthuyzen-Bakker M Mahdad R Vlasveld I De Boer MG Scheper H
Full Access

Aim. Rifampicin and fluoroquinolone based therapy is generally considered as first-choice targeted oral antimicrobial therapy for staphylococcal prosthetic joint infections (PJI) treated with debridement, antibiotics and implant retention (DAIR). Alternative equally effective antimicrobial strategies are urgently needed due to toxicity and drug-drug interactions that frequently occur with this strategy. Data from recent clinical studies suggests equipoise for other antimicrobial treatment regimens. The objective of the Rifampicin Combination Therapy versus Targeted Antimicrobial Monotherapy in the Oral Antimicrobial Treatment Phase of Staphylococcal Prosthetic Joint Infection (RiCOTTA)-trial is to evaluate whether monotherapy with clindamycin is non-inferior to rifampicin/fluoroquinolone combination therapy in patients with staphylococcal PJI that are treated with DAIR. Method. The RiCOTTA-trial is a multicenter, non-inferiority, open-label, randomized controlled trial evaluating clindamycin versus rifampicin/fluoroquinolone combination therapy in the oral treatment phase in patients with staphylococcal PJI managed with DAIR. The trial is performed in 16 hospitals in the Netherlands. Eligible patients are adults with staphylococcal knee or hip PJI managed by DAIR. Patients are included one to six days before antibiotic treatment is switched from intravenous to oral therapy. Patients with a contraindication for rifampicin, with a megaprosthesis or who receive intravenous antibiotics for more than three weeks after initial debridement are excluded. Primary outcome is treatment success one year after finishing antimicrobial treatment. Success is defined as the absence of: i. Infection related re-surgery, ii. New episode of antibiotic treatment for infection of the index joint after the initial treatment phase of 12 weeks, iii. Ongoing use of antibiotics for the index joint at the end of follow-up, iv. Death. The estimated treatment success of rifampicin combination therapy is 85% and the monotherapy strategy is considered not inferior when the difference in treatment success will be less than 10%. Enrolment of 158 patients per group (316 in total) is needed to confirm non-inferiority of monotherapy with a power of 80%. The trial is currently open for enrolment. The study is approved by the Medical Ethics Committee Leiden, the Hague, Delft, the Netherlands and registered under EU trial number 2022-501620-26-00 in Clinical Trial Information System. Conclusions. Currently, the RiCOTTTA study is the largest randomised clinical trial that compares targeted oral monotherapy with rifampicin combination treatment for staphylococcal PJI. Noninferiority of monotherapy would result in a change in national PJI guidelines and enable clinicians to use a more patient-tailored approach when considering antibiotics for patients during the oral treatment phase of PJI


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 22 - 22
22 Nov 2024
Söderquist B Möller M Salihovic S
Full Access

Aim. Dalbavancin is a lipoglycopeptide with a broad antimicrobial spectrum against Gram-positive bacteria and effect against microorganisms in biofilm in vitro. Its pharmacokinetic properties, with an exceptionally long half-life of approximately 300 hours, allow for simplified administration that may be of value in the long-term treatment of bone and joint infections, such as prosthetic joint infections (PJIs). Several case reports and case series with “off-lable” treatment with dalbavancin of PJIs exist, but the optimal dosing regimen remains to be defined. Therapeutic drug monitoring (TDM) is recommended for treatment with >2 doses of dalbavancin. In the absence of TDM, the Swedish national guidelines for bone and joint infections (2023, . www.infektion.net. ) recommends a loading dose of dalbavancin 1,500 mg on day 1 and 1,500 mg on days 8 – 14, after which from day 28 1,000 mg is given biweekly or 500 mg every week. The aim of the present study was to determine trough levels of dalbavancin in patients with long-term treatment of PJIs according to the national guidelines. Method. Twelve patients with PJI were treated with at least 6 doses of dalbavancin, of which the first two doses were 1500 mg and the following doses were 1000 every second week, and prospectively sampled biweekly for determination of serum concentrations (trough levels) of dalbavancin which was measured by liquid chromatography coupled to electrospray tandem mass spectrometry (LC-MS/MS). The renal function was also examined. Results. The median serum concentration 14 days after the first dose of dalbavancin 1500 mg was 36.3 mg/L (range 6.6 – 62.4 mg/L). The median value 14 days after the second dose of 1500 mg (day 27 – 28) was 48.2 mg/L (range 12.2 – 77.3 mg/L). The trough value after the last dose of a total of 6 – 7 doses was as median 43.1 mg/L (range 26.2 – 97.5 mg/L). Three patients showed a tendency towards successive accumulation of dalbavancin during treatment. None of the patients, including those three with increasing through levels during treatment, showed any significant alteration in creatinine nor glomerular filtration rate. Conclusions. TDM during long-term treatment with dalbavancin is recommended to avoid the risk of accumulation and unnecessarily high trough values. With TDM, the dosing interval can be extended in several cases. In addition, with the support of TDM, subtherapeutic serum concentrations, with the risk of developing resistance, can be avoided


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 27 - 27
14 Nov 2024
Bulut H Giray Batibay S Kanay E Özkan K
Full Access

Introduction. Despite the implementation of numerous preventive measures in recent years, the persistent challenge of periprosthetic infections remains. Among the various strategies, metallic modification of implants, particularly with silver, has emerged as a promising avenue. Silver's antimicrobial properties, coupled with its low human toxicity, render it an appealing option. However, ongoing debate surrounds its comparative efficacy in infection prevention when contrasted with titanium-coated prostheses. Methods. The PubMed database was systematically searched up to March 2024. Studies in English that met predetermined inclusion/exclusion criteria and utilized “Megaprosthesis AND infection” and “ silver-coated AND infection “ as key terms were included. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses(PRISMA) statement guided the article selection process. Results. From a pool of 1892 potential papers after literature screening, 11 studies with a total of 1419 patients were meticulously selected for analysis. Among these patients, 638 were treated with silver-coated implants, while 781 received titanium-coated implants, resulting in 166 recorded cases of infection. Remarkably, the infection rate stood at 9.2% for the silver-coated group, contrasting with 13.4% for the titanium-coated group. The subsequent analysis unveiled a notable discrepancy in proportions (P difference = -0.0473, 95%CI: -0.088 to -0.006), signaling a statistically significant decrease in infections within the silver-coated cohort. Furthermore, the I2 statistic, denoting heterogeneity in effect sizes, stood at 21.8% (95%CI: 0.0-66.9), indicating a modest degree of variability among the studies. Conclusion. In conclusion, our systematic review and meta-analysis shed light on the potential of silver-coated implants in mitigating periprosthetic infections. Despite the persistent challenge posed by such infections, our findings suggest a statistically significant decrease in infection rates among patients treated with silver-coated implants compared to those with titanium-coated ones


Bone & Joint Research
Vol. 13, Issue 11 | Pages 632 - 646
7 Nov 2024
Diaz Dilernia F Watson D Heinrichs DE Vasarhelyi E

Aims. The mechanism by which synovial fluid (SF) kills bacteria has not yet been elucidated, and a better understanding is needed. We sought to analyze the antimicrobial properties of exogenous copper in human SF against Staphylococcus aureus. Methods. We performed in vitro growth and viability assays to determine the capability of S. aureus to survive in SF with the addition of 10 µM of copper. We determined the minimum bactericidal concentration of copper (MBC-Cu) and evaluated its sensitivity to killing, comparing wild type (WT) and CopAZB-deficient USA300 strains. Results. UAMS-1 demonstrated a greater sensitivity to SF compared to USA300 WT at 12 hours (p = 0.001) and 24 hours (p = 0.027). UAMS-1 died in statistically significant quantities at 24 hours (p = 0.017), and USA300 WT survived at 24 hours. UAMS-1 was more susceptible to the addition of copper at four (p = 0.001), 12 (p = 0.005), and 24 hours (p = 0.006). We confirmed a high sensitivity to killing with the addition of exogenous copper on both strains at four (p = 0.011), 12 (p = 0.011), and 24 hours (p = 0.011). WT and CopAZB-deficient USA300 strains significantly died in SF, demonstrating a MBC-Cu of 50 µM against USA300 WT (p = 0.011). Conclusion. SF has antimicrobial properties against S. aureus, and UAMS-1 was more sensitive than USA300 WT. Adding 10 µM of copper was highly toxic, confirming its bactericidal effect. We found CopAZB proteins to be involved in copper effluxion by demonstrating the high sensitivity of mutant strains to lower copper concentrations. Thus, we propose CopAZB proteins as potential targets and use exogenous copper as a treatment alternative against S. aureus. Cite this article: Bone Joint Res 2024;13(11):632–646


Bone & Joint Research
Vol. 13, Issue 10 | Pages 546 - 558
4 Oct 2024
Li Y Wuermanbieke S Wang F Mu W Ji B Guo X Zou C Chen Y Zhang X Cao L

Aims

The optimum type of antibiotics and their administration route for treating Gram-negative (GN) periprosthetic joint infection (PJI) remain controversial. This study aimed to determine the GN bacterial species and antibacterial resistance rates related to clinical GN-PJI, and to determine the efficacy and safety of intra-articular (IA) antibiotic injection after one-stage revision in a GN pathogen-induced PJI rat model of total knee arthroplasty.

Methods

A total of 36 consecutive PJI patients who had been infected with GN bacteria between February 2015 and December 2021 were retrospectively recruited in order to analyze the GN bacterial species involvement and antibacterial resistance rates. Antibiotic susceptibility assays of the GN bacterial species were performed to screen for the most sensitive antibiotic, which was then used to treat the most common GN pathogen-induced PJI rat model. The rats were randomized either to a PJI control group or to three meropenem groups (intraperitoneal (IP), IA, and IP + IA groups). After two weeks of treatment, infection control level, the side effects, and the volume of antibiotic use were evaluated.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1084 - 1092
1 Oct 2024
Hammat AS Nelson R Davis JS Manning L Campbell D Solomon LB Gnanamanickam ES Callary SA

Aims

Our aim was to estimate the total costs of all hospitalizations for treating periprosthetic joint infection (PJI) by main management strategy within 24 months post-diagnosis using activity-based costing. Additionally, we investigated the influence of individual PJI treatment pathways on hospital costs within the first 24 months.

Methods

Using admission and procedure data from a prospective observational cohort in Australia and New Zealand, Australian Refined Diagnosis Related Groups were assigned to each admitted patient episode of care for activity-based costing estimates of 273 hip PJI patients and 377 knee PJI patients. Costs were aggregated at 24 months post-diagnosis, and are presented in Australian dollars.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1067 - 1073
1 Oct 2024
Lodge CJ Adlan A Nandra RS Kaur J Jeys L Stevenson JD

Aims

Periprosthetic joint infection (PJI) is a challenging complication of any arthroplasty procedure. We reviewed our use of static antibiotic-loaded cement spacers (ABLCSs) for staged management of PJI where segmental bone loss, ligamentous instability, or soft-tissue defects necessitate a static construct. We reviewed factors contributing to their failure and techniques to avoid these complications when using ABLCSs in this context.

Methods

A retrospective analysis was conducted of 94 patients undergoing first-stage revision of an infected knee prosthesis between September 2007 and January 2020 at a single institution. Radiographs and clinical records were used to assess and classify the incidence and causes of static spacer failure. Of the 94 cases, there were 19 primary total knee arthroplasties (TKAs), ten revision TKAs (varus-valgus constraint), 20 hinged TKAs, one arthrodesis (nail), one failed spacer (performed elsewhere), 21 distal femoral endoprosthetic arthroplasties, and 22 proximal tibial arthroplasties.


Bone & Joint Research
Vol. 13, Issue 10 | Pages 525 - 534
1 Oct 2024
Mu W Xu B Wang F Maimaitiaimaier Y Zou C Cao L

Aims

This study aimed to assess the risk of acute kidney injury (AKI) associated with combined intravenous (IV) and topical antibiotic therapy in patients undergoing treatment for periprosthetic joint infections (PJIs) following total knee arthroplasty (TKA), utilizing the Kidney Disease: Improving Global Outcomes (KDIGO) criteria for classification.

Methods

We conducted a retrospective analysis of 162 knees (162 patients) that received treatment for PJI post-TKA with combined IV and topical antibiotic infusions at a single academic hospital from 1 January 2010 to 31 December 2022. The incidence of AKI was evaluated using the KDIGO criteria, focussing on the identification of significant predictors and the temporal pattern of AKI development.