header advert
Results 151 - 200 of 2550
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 7 - 7
23 Jun 2023
van Hellemondt GG Faraj S de Windt T van Hooff M Spruit M
Full Access

Pelvic discontinuity (PD) is a detrimental complication following total hip arthroplasty (THA). The aim of this study was to assess the clinical and radiological results of patients with PD who were revised using a custom-made triflange acetabular component (CTAC).

This is a single centre prospective study of patients with PD following THA who were treated with a CTAC. The Hip Disability and Osteoarthritis Outcome Score (HOOS), modified Oxford Hip Score (mOHS), EurQol five-dimension three-level (EQ-5D-3L) utility, and Numeric Rating Scale (NRS), including visual analogue score (VAS) for pain, were gathered at baseline, and at one- and two-year follow-up. Clinical and radiological complications, including reasons for revisions were registered. Trends over time are described and tested for significance and clinical relevance.

18 females with 22 CTACs were included with a mean age of 73.5 years (SD 7.7). There were significant improvements between baseline and final follow-up in HOOS (p<0.01), mOHS (p<0.01), EQ-5D-3L utility (p<0.01), EQ-5D-3L NRS (p<0.01), VAS pain rest (p<0.01), and VAS pain activity (p<0.01). A minimal clinically important improvement in mOHS and the HOOS was observed in 16 patients (73%) and 14 patients (64%), respectively. Definite healing of the PD was observed in 19 hips (86%). Complications included six cases with broken screws (27%), four cases (18%) with bony fractures, and one case (4.5%) with sciatic nerve paresthesia. One patient with concurrent bilateral PD had revision surgery due to recurrent dislocations. No revision surgery was performed for screw failure or implant breakage.

This is the first prospective assessment in clinical outcome of patients with PD who were treated with a CTAC. We have demonstrated that CTAC in patients with THA acetabular loosening and PD can result in stable constructs with no mechanical failures. Moreover, clinically relevant improvements in health-related quality of life at two years’ follow-up was observed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 36 - 36
23 Jun 2023
Bizot P
Full Access

Genetic skeletal disorders constitute a rare and heterogeneous bone diseases often leading to poor quality of life. Several surgical options are available. The surgeon must deal with specific features (bone deformity, previous procedures, abnormal bone quality, stiffness or instability, muscle weakness). The questions concern the feasibility of the procedures and the surgical strategy.

55 patients (26 W, 29 M) were reviewed between 2016 and 2022. The mean age of the patients was 35 years (17–71). The diagnosis included 9 hereditary multiple exostoses, 8 osteogenesis imperfecta, 6 multiple epiphyseal dysplasia congenita, 6 achondroplasia, 4 osteopetrosis, 3 pycnodysostosis, 3 hypophosphatemic rickets, 3 fibrous dysplasia, 2 mucopolysaccharidosis, and 10 miscellaneous. 25 patients were referred for hip problems (40 hips). 4 patients (7 hips) requiring a THA have not been operated (4 planned). 4 patients (6 hips) had a proximal femoral fixation (2 osteotomies, 4 fracture fixations). 17 patients (27 hips) sustained a THA (25 primary, 2 revisions). All of them were operated by one operator, using a posterolateral approach and standard implants (including 7 dysplastic and 2 short stems). No customized implant has been used.

As regard the 27 THAs, the mean follow up was 4.2 years (1–12). The early complications included 2 femoral cracks and 1 femur fracture. There were 2 revisions (1 cup loosening at 2 years, 1 stem loosening at 4 years). No infection nor dislocation occurred. All the patients were satisfied with their treatment and regain some autonomy. 3 THA were considered as unfeasible.

Constitutional bone diseases need a multidisciplinary program of care. The indication for surgery is based on a mutual trust patient/surgeon, a careful evaluation of benefits/risks, and an accurate imaging to anticipate the difficulties. The expected results are a better function and quality of life, and a stability over time.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 40 - 40
23 Jun 2023
Millis MB Vakulenko-Lagun B Almakaris R Kim HJ
Full Access

LCPD can cause femoral head deformity and osteoarthritis requiring total hip replacement (THR). Currently, there is little data on how patients are functioning after a THR from patients’ perspective. The purpose of this study was to collect a large patient-reported outcome data set on adults with LCPD, including those who had a THR, using a Web-survey method and to compare their outcomes to a normative population.

An English REDCap-based survey was built and made available on a LCPD study group website. The survey included childhood and adult LCPD history, SF-36 Health Survey, and the Hip Disability and Osteoarthritis Outcome Score (HOOS). Statistical analysis included t-test and linear and proportional odds regressions.

Of the 1182 participants who completed the survey, 261 participants (89 M, 172 F) had a THR. The mean age at survey was 44.6±12.4 years (range 20–79). The mean duration since THR was 7.2±8 years (median 4, range 0–43). Gender and age matched analysis showed that THR participants had significantly lower HOOS Quality-of-Life and Sports scores (p<0.0001) for all age groups in comparison to a normative cohort. In women, the HOOS Symptoms, Daily Living, and Pain scores were also significantly lower in the <55 age groups (p<0.05). Similarly, SF-36 scores were significantly lower (p<0.05) in female <45 age groups in 5 out of 8 SF-36 scales. Overall, hip dysplasia and the number of years-from-THR were the main factors associated with worse SF-36 and HOOS scores. In comparison to the non-THR participants, THR participants had higher scores in some of the HOOS and SF-36 scales.

LCPD participants with THR had significantly worse HOOS and SF-36 scores in most of the scales studied than a normative cohort, especially in women. There is significant disability even after a THR, warranting continued efforts to improve treatment and outcome.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 44 - 44
23 Jun 2023
Scholz J Perka C Hipfl C
Full Access

Dual-mobility (DM) bearings are effective to mitigate dislocation in revision total hip arthroplasty (THA). However, data on its use for treating dislocation is scarce. Aim of this study was to compare DM bearings, standard bearings and constrained liner (CL) in revision THA for recurrent dislocation and to identify risk factors for re-dislocation.

We reviewed 100 consecutive revision THAs performed for dislocation from 2012 and 2019. 45 hips (45%) received a DM construct, while 44 hips (44%) and 11 hips (11%) had a standard bearing and CL, respectively. Rates of re-dislocation, re-revision for dislocation and overall re-revision were compared. Radiographs were assessed for cup positioning, restoration of centre of rotation, leg length and offset. Risk factors for re-dislocation were determined by cox regression analysis. Modified Harris hip scores (mHHS) were calculated. Mean follow-up was 53 months (1 to 103).

DM constructs were used more frequently in elderly patients (p=0.011) and hips with abductor deficiency (p< 0.001). The re-dislocation rate was 11.1% for DM bearings compared with 15.9% for standard bearings and 18.2% for CL (p=0.732). Revision-free survival for DM constructs was 83% (95% CI 0.77 – 0.90) compared to 75% (95% CI 0.68 – 0.82) for standard articulations and 71% (95% CI 0.56 – 0.85) for CL (p=0.455). Younger age (HR 0.91; p=0.020), lower comorbidity (HR 0.42; p=0.031), smaller heads (HR 0.80; p=0.041) and cup retention (HR 8.23; p=0.022) were associated with re-dislocation. Radiological analysis did not reveal a relationship between restoration of hip geometry and re-dislocation. mHHS significantly improved from 43.8 points to 65.7 points (p<0.001) with no differences among bearing types.

Our findings suggest that DM bearings do not sufficiently prevent dislocation in revision THA for recurrent dislocation. Reconstruction of the abductor complex may play a key role to reduce the burden in these high-risk patients.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 23 - 23
23 Jun 2023
Fehring TK Odum S Rosas S Buller LT Ihekweazu U Joseph H Gosthe RG Springer BD
Full Access

Periprosthetic joint infections (PJIs) centers are garnering the attention of different arthroplasty surgeons and practices alike. Nonetheless, their value has yet to be proven. Therefore, we evaluated weather PJI centers produce comparable outcomes to the national average of THA PJIs on a national cohort.

We performed a retrospective review of patient data available on PearlDiver from 2015 – 2021. PJI THA cases were identified through ICD-10 and CPT codes. Patients treated by 6 fellowship trained arthroplasty surgeons from a PJI center were matched based on age, gender, Charlson Comorbidity Index and Elixhauser comorbidity index at a 1:1 ratio to patients from the national cohort. Compared outcomes included LOS, ED visits, number of patients readmitted, total readmissions. Sample sized did not allow the evaluation of amputation, fusion or explantation. Normality was tested through the Kolmogorov-Smirnov test. And comparisons were made with Students t-tests and Chi Square testing.

A total of 33,001 THA PJIs and were identified. A total of 77 patients were identified as treated by the PJI center cohort and successfully matched. No differences were noted in regard to age, gender distribution, CCI or ECI (p=1, 1, 1 and 0.9958 respectively). Significant differences were noted in mean LOS (p<0.43), number of patients requiring readmissions (p=0.001) and total number of readmission events (p<0.001). No difference was noted on ED visits.

Our study demonstrates that a PJI for THA cases may be beneficial for the national growing trend of arthroplasty volume. Future data, that allows comparison of patient's specific data will allow for further validation of PJI centers and how these can play a role in helping the national PJI growing problem.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 28 - 28
23 Jun 2023
Massè A Giachino M Audisio A Donis A Secco D Turchetto L Limone B Via RG Aprato A
Full Access

Ganz's studies made it possible to address joint deformities on both femoral and acetabular side brought by the Legg-Calvè-Perthes disease (LCPD). Femoral head reduction osteotomy (FHRO) was developed to improve joint congruency along with periacetabular osteotomy (PAO). The purpose of this study is to show the clinical and morphologic outcomes of the technique, and an implemented planning approach.

From 2015 to 2023, 13 FHROs were performed on 11 patients for LCPD, in two centers. 11 of 13 hips had an associated PAO. A specific CT and MRI-based protocol for virtual simulation of the corrections was developed. Outcomes were assessed with radiographic parameters (sphericity index, extrusion index, integrity of the Shenton's line, LCE angle, Tonnis angle, CCD angle) and clinical parameters (ROM, VAS, Merle d'Aubigné-Postel score, modified-HHS, EQ5D-5L). Early and late complications were reported.

The mean follow-up was 40 months. The mean age at surgery was 11,4 years. No major complications were recorded. One patient required a total hip arthroplasty. Femoral Head Sphericity increased from 45% to 70% (p < 0,001); LCE angle from 18° to 42,8° (p < 0,001); extrusion Index from 36,6 to 8 (p < 0,001); Tonnis Angle from 14,4° to 6,2° (p = 0.1); CCD Angle from 131,7 to 136,5° (p < 0,023). The VAS score improved from 3,25 to 0,75,(p = 0.06); Merle d'Aubigné-Postel score from 14.75 to 16 (p = 0,1); Modified-HHS from 65,6 to 89,05 (p = 0,02). The EQ 5D 5L showed significant improvements. ROM increased especially in abduction and extra-rotation.

FHRO associated with periacetabular procedures is a safe technique that showed improved functional, clinical and morphologic outcomes in LCPD. The newly introduced simulation and planning algorithm may help to further refine the technique.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 33 - 33
23 Jun 2023
Engh CA Bhal V Hopper RH
Full Access

When the Birmingham Hip Resurfacing (BHR) metal-on-metal implant system was approved by the United States Food and Drug Administration in 2006, a multicenter, prospective, post-approval study (PAS) was required. This study uses data from the PAS to investigate metal level and glomerular filtration rate (GFR) trends over the first decade in vivo.

Between October 2006 and March 2011, 290 primary BHR procedures were performed among 262 patients at 5 sites. Whole blood samples were sent to a single specialized laboratory to determine GFR, cobalt (Co) and chromium (Cr) levels. The population for this study consists of 117 unrevised unilateral patients with a mean age at surgery of 51.3±6.5 years who had pre-operative, 1-year, 4-year, 5-year and 10-year laboratory data. The mean follow-up for these patients that included 36 females was 10.1±0.2 years.

Median metal levels at 1-year increased relative to pre-operative values for Co (by a factor of 9.7 from 0.13 to 1.26 ppb, p<0.001) and Cr (by a factor of 2.5 from 0. 60 to 1.50 ppb, p<0.001). Metal levels subsequently remained relatively constant over time with a median 10-year value of 1.12 ppb for Co and 1.29 ppb for Cr. Based on 585 blood samples from all 117 patients, there was no relationship between GFR and Co (=−0.06, p=0.14) or Cr (=0.05, p=0.27) levels. However, lower pre-operative GFR values were associated with larger increases in Co at 1-year relative to the pre-operative level (=−0.26, p=0.005). There was no relationship between pre-operative GFR values and changes in Cr at 1 year (=−0.13, p=0.15).

Through the first decade in vivo, elevated whole blood metal levels for unilateral BHR patients do not appear to adversely affect GFR. However, patients with lower pre-operative GFR values tend to have larger increases in their Co level at 1-year.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 34 - 34
23 Jun 2023
Bunyoz KI Tsikandylakis G Mortensen K Gromov K Mohaddes M Malchau H Troelsen A
Full Access

In metal-on-polyethylene (MoP) THA large femoral metal heads are designed to increase stability and to reduce dislocation risk. The increased head size could lead to increased taper corrosion with the release of metal ions and adverse reactions. Using blood ion measurements, we aimed to investigate the association between femoral head size and metal-ion release after MoP THA.

96 patients were enrolled at two centers and randomized to receive either a 32-mm metal head or a 36–44 mm metal head (the largest possible fitting the thinnest available polyethylene insert). Blood metal ions and PROMs (OHS, UCLA) were measured at two- and five-year follow-ups.

Both 2- and 5-year median chrome, cobalt, and titanium levels were below taper corrosion indicative ion levels. At 5 years, median chrome, cobalt, and titanium levels were 0.5 μg/L (0.50–0.62), 0.24 μg/L (0.18–0.30), and 1.16 μg/L (1.0–1.68) for the 32-mm group, and 0.5 μg/L (0.5–0.54), 0.23 μg/L (0.17–0.39), and 1.30 μg/L (1–2.05) for the 36–44 mm group, with no difference between groups (p=0.825, p=1.000, p=0.558). At 2 years, 7 (32-mm) versus 4 (36–44-mm) patients had elevated ions. At 5 years, 6 (32-mm) versus 7 (36–44-mm) patients had elevated ions. There was no difference in either OHS (p=0.665) or UCLA (p=0.831) between patients with or without elevated blood metal ions.

5 years after the insertion of MoP THAs, we found no differences in the blood metal ion levels between 32 mm heads and 36–44 mm heads and no corrosion-related revisions. As taper corrosion can debut after 5 years, there is still a need for long-term follow-up studies on the association between head size and corrosion in MoP THA.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 48 - 48
23 Jun 2023
Carender CN Perry KI Sierra RJ Trousdale RT Berry DJ Abdel MP
Full Access

There is a paucity of long-term data on modular fluted tapered (MFT) stems for two-stage reimplantation following periprosthetic joint infection (PJI). The purpose of this study was to evaluate implant survivorship, radiographic results, and clinical outcomes in a large cohort of reimplantation THAs using MFT stems.

We identified 236 reimplantation THAs from a single tertiary care academic institution from 2000 to 2020. Two designs of MFT stems were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years, mean BMI was 32 kg/m2, and 46% were female. Median stem diameter was 19 mm, and median stem length was 195 mm. Mean follow-up was 7 years. A competing risk model accounting for death was utilized.

The 15-year cumulative incidence of any revision was 24%. There were 48 revisions, with the most common reasons being dislocation (n=25) and PJI (n=16). The 15-year cumulative incidence of any reoperation was 28%. Only 13 revisions involved the fluted tapered portion of the component (FTC), for a 15-year cumulative incidence of any FTC revision of 8%. Only 2 FTCs were revised for aseptic loosening, resulting in a 15-year cumulative incidence of FTC revision for aseptic loosening of 1%. Stem subsidence >5 mm occurred in 2% of unrevised cases, and all stems were radiographically stable at most recent follow-up. Mean HHS was 77 at most recent follow-up.

This series demonstrated that MFT stems were durable and reliable even in the setting of two-stage reimplantation for infection. While the incidence of aseptic loosening was very low, the incidence of any revision was 24% at 15 years, primarily caused by dislocation and recurrent PJI.

Level of Evidence: IV


Dual mobility cups (DMC) reduce the risk of dislocation in femoral neck fractures (FNF). Direct anterior approach (DAA), historically promoted for better stability, has been developed in recent years for better functional results. The aim of this study was to compare the early functional results of DMC in FNF by DAA versus posterolateral approach (PLA).

A prospective study was conducted on a continuous series of patients who received DMC for FNF by DAA or PLA. The primary endpoint was Harris Hip Score and Parker score assessed at the first follow-up visit. Intraoperative complications were collected during hospitalization. One year clinical results and all cause revision rate were also collected. Radiographic data of cup positioning and limb length were evaluated.

Fifty-two patients were included in the DAA group and 54 in the PLA group. Two patients were lost to follow-up. The mean age was 72.8 years. There was no significant difference in HHS or Parker score at 3 and 12 months follow up (p=0.6, p= 0.75). DAA was associated with more intraoperative complications with 4 fractures and 1 femoral nerve deficit (p=0.018). There were 3 revisions in the DAA group (1 infection, 1 dislocation, 1 peri prosthetic fracture) and 1 in the PLA group (infection), which was not statistically significant (p=0.34). Cup anteversion was 6° greater and inclination 9° lesser in DAA group (p=0.028, p<0.01).

Results suggest that DAA does not provide any early functional benefit in THA-DMC for FNF compared to PLA. It could lead to more intraoperative complications and a higher revision rate. DAA requires an experienced surgeon and careful patient selection.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 58 - 58
23 Jun 2023
Fontalis A The CS Plastow R Mancino F Haddad FS
Full Access

In-hospital length of stay (LOS) and discharge disposition following arthroplasty could act as surrogate measures for improvement in patient pathways, and have major cost saving implications for healthcare providers. With the ever-growing adoption of robotic technology in arthroplasty, we wished to evaluate its impact on LOS. The objectives of this study were to compare LOS and discharge disposition following robotic-arm assisted (RO THA) versus conventional technique Total Hip Arthroplasty (CO THA).

This large-scale, single institution study included patients of any age undergoing primary THA (N = 1,732) for any cause between May 2019 and January 2023. Data extracted included patient demographics, LOS, need for Post Anaesthesia Care Unit (PACU) admission, anaesthesia type, readmission within 30 days and discharge dispositions. Univariate and multivariate logistic regression models were also employed to identify factors and patient characteristics related to delayed discharge.

The median LOS in the RO THA group was 54 hours (34, 78) versus 60 (51, 100) in the CO THA group, p<0.001. Discharge disposition was comparable between the two groups. In the multivariate model, age, need for PACU admission, ASA score > 2, female gender, general anaesthesia and utilisation of the conventional technique were significantly associated with LOS > 2 days.

Our study showed that robotic-arm assistance was associated with a shorter LOS in patients undergoing primary THA and no difference in discharge destination. Our results suggest that robotic-arm assistance could be advantageous in partly addressing the upsurge of hip arthroplasty procedures and the concomitant health care burden; however, this needs to be corroborated by long-term cost effectiveness analyses and data from randomised controlled studies.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 79 - 79
23 Jun 2023
Paprosky W Gerlinger T
Full Access

Previous reports on the outcomes of isolated head and liner exchange in revision total hip arthroplasty have found high rates of instability following these surgeries. Most reports have studied constructs using ≤28mm femoral heads. The purpose of this study was to determine if modern techniques with the use of larger head sizes can improve the rate of instability after head and liner exchange.

We identified 138 hips in 132 patients who underwent isolated head and liner exchange for polyethylene wear/osteolysis (57%), acute infection (27%), metallosis (13%), or other (2%). All patients underwent revision with either 32mm (23%), 36mm (62%), or 40mm (15%) diameter heads. Crosslinked polyethylene was used in all revisions. Lipped and/or offset liners were used in 104 (75%) hips. Average follow up was 3.5 (1.0–9.1) years. Statistical analyses were performed with significance set at p<0.05.

Revision-free survivorship for any cause was 94.6% and for aseptic causes was 98.2% at 5 years. 11 (8%) hips experienced a complication with 7 (5%) hips requiring additional revision surgery. Following revision, 4 (3%) hips experienced dislocation, 5 (4%) hips experienced infection, and 1 (1%) hip was revised for trunnionosis. No demographic or surgical factors significantly affected outcomes.

Our study shows that isolated head and liner exchange using large femoral heads and modern liners provides for better stability than previous reports. The most common complication was infection. We did not identify specific patient, surgical or implant factors that reduced the risk of instability or other complication.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 80 - 80
23 Jun 2023
Halken CH Jensen CB Henkel C Gromov K Troelsen A
Full Access

The interest in day-case hip arthroplasty is increasing; however, there are conflicting results regarding readmission risk, and little is known about patients’ attitude towards day-case surgery. We aimed to investigate differences in 30-day readmission rates between day-case patients and single-overnight-stay patients following total hip arthroplasty (THA) and explore patients’ attitude towards day-case surgery.

From the Danish National Patient Register we identified 29,486 THAs (1353 day-case THAs and 28,133 single-overnight-stay THAs) performed between 2010 and 2020. Day-case surgery was defined as discharge on the day-of-surgery. Overnight admissions within 30 days of surgery were considered readmissions. Differences in readmission rates between day-case and single-overnight-stay patients were investigated using logistic regression adjusted for patient characteristics and year of surgery. In a single-center descriptive study, 2395 hip arthroplasty patients from 2016 to start-2023 answered a questionnaire on patient characteristics, attitude towards day-case surgery and patient-reported outcome measures (PROM).

The overall 30-day readmission rate was 4.4% (CI: 4.2–4.6%) with no difference between day-case (4.4%) and single-overnight-stay THAs (4.4%) (odds-ratio: 1.2 [CI: 0.91–1.6]). In the descriptive study answers to the question whether patients were interested in being discharged on the day of surgery, were: “Yes” = 41%, “Do not know” = 20%, “No” = 39%. Patients responding “No” had lower preoperative PROM-scores, were older (“No” = 70.2 y vs. “Yes” = 65.3 y), and more often female (“No” = 72% vs. “Yes” = 52% female).

Based on nationwide data from 2010–2020, day-case THA patients were not more likely to be readmitted compared to single-overnight-stay patients. However, most patients were not positive towards day-case surgery. While surgeons may consider day-case surgery to be safe, patients are not intuitively positive, indicating an attitude mismatch. To achieve high success rate and patient satisfaction in day-case surgery, shared-decision making initiatives within day-case surgery are needed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 47 - 47
23 Jun 2023
Garbuz DS
Full Access

The purpose of this study was to determine long-term survival free from all-cause revision and stem-related failure, as well as radiographic and functional outcomes of the ZMR stem in revision THA.

We retrospectively identified all patients in our institutional database who underwent revision THA using the ZMR Revision Hip system from the year 2000 to 2007 (minimum two-year follow-up). Of the 112 ZMR hips (110 patients) identified, a total of 106 hips (104 patients) met inclusion criteria. The mean study follow-up 13.9 years (range 2–22). Indications for index ZMR revision included aseptic loosening (72.1%), periprosthetic joint infection (17.3%), periprosthetic fracture (9.6%), and stem fracture (1.0%). Kaplan-Meier analysis was used to determine the all-cause and stem-related failure revision-free survival. Validated patient reported outcomes were collected and available radiographs were reviewed to determine implant stability.

A total of 17 hips (16.0%) underwent a re-revision of any component. The indications for re-revision were stem failure (35.3%), infection (29.4%), instability (29.4%), and aseptic loosening of the acetabular component (5.9%). The five- and 15-year all-cause survivorship was 89.5% (95% CI 86.5–92.5) and 83.0% (95% CI 79.2–86.8), respectively. There were six re-revisions for stem failure (5.7%); five for stem fracture and one for aseptic loosening. The average time to stem failure was 4.6 years (range 1.3–8.2). The five- and 15-year survivorship free from stem-related failure was 97.2% (95% CI 95.6–98.8) and 93.9% (95% CI 91.5–96.3), respectively. At final follow-up the mean Oxford hip score was 36.9 and all surviving ZMR stems were well fixed on radiographs.

Femoral revision with the ZMR stem offers satisfactory long-term survivorship and promising clinical outcomes. Although uncommon, stem fracture was the most common reason for stem-related failure.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 63 - 63
23 Jun 2023
Czubak J Kołodziejczyk K Czwojdziński A Czubak-Wrzosek M
Full Access

The aim of the study was to evaluate radiological and clinical outcomes of surgical treatment of developmental dysplasia of the hip (DDH) with Periacetabular Osteotomy (PAO) and to determine the values of radiological parameters allowing us to obtain an optimal clinical result.

Radiological evaluation included a standardized AP digital radiograph of the hip joints. Centre edge angle (CEA), medialization, distalization, femoral head coverage (FHC) and ilioischial angle were measured. Clinical evaluation based on HHS, WOMAC, Merle d'Aubigne-Postel scales and Hip Lag Sign. Radiological and clinical evaluation was performed preoperatively and approximately 12 months after the surgery.

Statistically significant (p<0.05) differences in radiological measurements and all clinical scales have been observed pre- and postoperatively for all of the parameters. The results of PAO presented decreased medialization by 3.4mm (range: 3 to 3.7), distalization by 3.5mm (range: 3.2 to 3.8) and the ilioischial angle by 2.7° (range: 2.2 to 3.7). There was also an improvement in the femoral head bone coverage: CEA increased by 16.3° (range: 12.1˚ to 20.5˚) and FHC by 15.2% (range: 10.8 to 19.8). Clinically we observed an increase in HHS by 22 points (range: 15.8 to 28.2) and M. Postel d'Aubigne by 3.5 points (range: 2.0 to 4.4) and a decrease in WOMAC by 24% (range: 22.6 to 25.8). HLS improvement of gluteal muscles’ efficiency has been observed in 67% of patients postoperatively.

This study revealed that the qualification of patients with DDH for an elective PAO is more justified due to the predicted optimal clinical outcomes based on three parameters: CEA <25 degrees, FHC <75%, and ilioischial angle >85.9 degrees. Accordingly, to achieve better clinical results for all scales, it is necessary to increase the average CEA value by 11˚, the average FHC by 11%, and reduce the average ilioischial angle by 3˚.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 66 - 66
23 Jun 2023
Chosa E Zhao X
Full Access

Finite element analysis (FEA) has been applied for the biomechanical analysis of acetabular dysplasia, but not for biomechanical studies of periacetabular osteotomy (PAO) or those performing analysis taking into consideration the severity of acetabular dysplasia. This study aimed to perform biomechanical evaluation of changes in stress distribution following PAO and to determine the effect of the severity of developmental dysplasia of the hip (DDH) using three-dimensional FEA.

A normal model was designed with a 25° center-edge (CE) angle and a 25° vertical-center-anterior margin (VCA) angle. DDH models were designed with CE and VCA angles each of 10, 0, or −10°. Post-PAO models were created by separating each DDH model and rotating the acetabular bone fragment in the anterolateral direction so that the femoral head was covered by the acetabular bone fragment, with CE and VCA angles each at 25°.

Compared to the normal hip joint model, the DDH models showed stress concentration in the acetabular edge and contacting femoral head, and higher stress values; stress increased with decreasing CE and VCA angles. Compared to the DDH models, the post-PAO models showed near-normal patterns of stress distribution in the acetabulum and femoral head, with stress concentration areas shifted from the lateral to medial sides. Stress dispersion was especially apparent in the severe acetabular dysplasia models. PAO provided greater decreases in the maximum values of von Mises stress in the load-bearing area of the acetabulum and femoral head when applied to the DDH models of higher degrees of severity, although the values increased with increasing severity of DDH. PAO is expected to provide biomechanical improvement of the hip joint, although the results also suggest a limitation in the applicability of PAO for the patients with severe acetabular dysplasia.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 70 - 70
23 Jun 2023
Muratoglu OK Asik MD Nepple CM Wannomae KK Micheli BR Connolly RL Oral E
Full Access

Majority of ultra-high molecular weight polyethylene (UHMWPE) medical devices used in total joint arthroplasty are crosslinked using gamma radiation to improve wear resistance. Alternative methods of crosslinking are urgently needed to replace gamma radiation due to rapid decline in its supply. Peroxide crosslinking is a candidate method with widespread industrial applications. Oxidative stability and biocompatibility, which are critical requirements for medical device applications, can be achieved using vitamin-E as an additive and by removing peroxide by-products through high temperature melting, respectively. We investigated compression molded UHMWPE/vitamin-E/di-cumyl peroxide blends followed by high-temperature melting in inert gas as a material candidate for tibial knee inserts. Wear resistance increased and mechanical properties remained largely unchanged. Oxidation induction time was higher than most of the other clinically available formulations. The material passed the local-end point biocompatibility tests per ISO 10993. Compounds found in exhaustive extraction were of no concern with margin-of-safety values well above the accepted level, indicating a desirable toxicological risk profile. Peroxide crosslinked, vitamin-E stabilized, and high temperature melted UHMWPE has recently been cleared for clinical use in tibial knee inserts. With all the salient characteristics needed in a material that can provide superior long-term performance in total joint patients, peroxide crosslinking can replace gamma radiation crosslinking of UHMWPE for use in all total joint replacement implant including acetabular liners.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 71 - 71
23 Jun 2023
Sedel L
Full Access

Since 1977 we did implant ceramic on ceramic THR in younger and active population. In 1991 we published (JBJS B N°4) data's in a consecutive group of patients under 50 years of age.

What about the same patients for more than 30 years? Eighty-six hips in 75 patients, 41 males 34 females, mean age 43 (18 to 50), mean weight 68 kg (36 to 100), Charnley class: 38 A, 28 (38 hips) B, 9 patients (10 hips) C. Sixty-six primary procedures, 20 revisions (18 failed arthroplasties: 6 THR, 5 resurfacing, four single cup, two hemiarthroplasty, one bipolar), one after acetabular fractures. Four hips previously infected.

Eight Patients deceased (8 hips) prosthesis still in place, ten lost to follow-up before 2 years, eight hips in 8 patients were revised before the review, partially followed: from 2 to 20 years: 35, completely followed: 25 hips in 23 patients resuming in: No pain in 20, slight pain in 2, severe disability in 3 not related to the hip, no radiolucent lines in 22, radiolucent lines in 3, no osteolysis in 25.

Revision for: early sepsis in one, socket loosening in 8 (3 revisions cases), femoral head fractures in 2: one extra small head (22mm) for Crowe 3 DDH, one fractured at 24 years.

Inertness, stability related to fibrous tissue generation, no noise.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 73 - 73
23 Jun 2023
Sheth N Bostrom M Winzenrieth R Humbert L Pearman L Caminis J Wang Y Boxberger J Krohn K
Full Access

To evaluate the effects of 6 and 18 months of abaloparatide (ABL) compared with placebo (PBO) on bone mineral density (BMD) in the acetabular regions of postmenopausal women with osteoporosis (OP).

Acetabular bone loss, as may occur in OP, increases risk of acetabular fragility fracturesa. In total hip arthroplasty (THA), low acetabular BMD adversely affects primary stability, osseointegration, and migration of acetabular cups.c ABL is an osteoanabolic agent for the treatment of men and postmenopausal women with OP at high risk for fracture. Effects of ABL on acetabular BMD are unknown.

Hip DXA scans were obtained at baseline, 6, and 18 months from a random subgroup of postmenopausal women (aged 49–86 y) from the phase 3 ACTIVE trial randomized to either ABL 80 µg/d or PBO (n=250/group). Anatomical landmarks were identified in each DXA scan to virtually place a hemispherical shell model of an acetabular cup and define regions of interest corresponding to DeLee & Charnley zones 1 (R1), 2 (R2), and 3 (R3). BMD changes compared to baseline were calculated for each zone. Statistical P values were based on a repeated mixed measures model.

BMD in all zones were similar at baseline in the ABL and PBO groups. BMD significantly increased in the ABL group at 6 and 18 months compared with PBO (all P<0.0001 vs PBO). BMD in the PBO group was relatively stable over time.

ABL treatment resulted in rapid and progressive increases in BMD of all 3 acetabular zones. Increasing acetabular BMD has the potential to improve acetabular strength, which may reduce risk of acetabular fragility fractures. In bone health optimization prior to THA, increased acetabular BMD via ABL may provide better primary stability and longevity of acetabular cups in postmenopausal women with OP.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 76 - 76
23 Jun 2023
Bloch B James P Manktelow A
Full Access

Sound management decisions are critical to outcomes in revision arthroplasty. Aiming to improve outcomes, revision networks facilitate speciality trained, high volume surgeons, share experience and best practice, contributing to decision making within and away from their base hospital. We have reported the early clinical experience of East Midlands Specialist Orthopaedic Network (EMSON). In this paper we report beneficial clinical effects, both demonstrable and unquantifiable supporting the process.

Using the UK HES database of revisions, performed before and after EMSON was established, (April 2011 – March 2018), data from EMSON hospitals were compared to all other hospitals in the same time-period. Primary outcome was re-revision surgery within 1 year. Secondary outcomes were re-revision, complications within first two years and median LOS.

57,621 RTHA and 33,828 RTKA procedures were involved with around 1,485 (2.6%) and 1,028 (3.0%) respectively performed within EMSON. Re-revision THA rates, within 1 year, in EMSON were 7.3% and 6.0% with re-revision knee rates 11.6% and 7.4%, pre- and post-intervention. Re-revision rates in the rest England in the same periods were 7.4% to 6.8% for hips and 11.7% to 9.7% for knees. This constituted a significant improvement in 1-year re-revision rates for EMSON knees. (β = −0.072 (−0.133 to −0.01), p = 0.024). The reduction in hip re-revision did not reach statistical significance. Secondary outcomes showed a significant improvement for 1 and 2-year RTHA complication rates.

Re-revision rates for RTKA and complication rates for RTHA improved significantly after the introduction of EMSON. Other outcomes studied also improved to a greater extent in the network hospitals. While anecdotal experience with networks is positive, the challenge in collating data to prove clinic benefit should not be underestimated. Beyond the formal process, additional communication, interaction, and support has immeasurable benefit in both elective and emergency scenarios.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 4 - 4
23 Jun 2023
Gross A Safir O Kuzyk P
Full Access

Pelvic discontinuity is a separation through the acetabulum with the ilium displacing superiorly and the ischium/pubis displacing inferiorly. This is a biomechanically challenging environment with a high rate of failure for standard acetabular components. The cup-cage reconstruction involves the use of a highly porous metal cup to achieve biological bone ingrowth on both sides of the pelvic discontinuity and an ilioischial cage to provide secure fixation across the discontinuity and bring the articulating hip center to the correct level. The purpose of this study was to report long term follow up of the use of the cup-cage to treat pelvic discontinuity.

All hip revision procedures between January 2003 and January 2022 where a cup-cage was used for a hip with a pelvic discontinuity were included in this retrospective review. All patients received a Trabecular Metal Revision Shell with either a ZCA cage or TMARS cage (Zimmer-Biomet Inc.). Pelvic discontinuity was diagnosed on pre-operative radiographs and/or intraoperatively. Kaplan-Meier survival analysis was performed with failure defined as revision of the cup-cage reconstruction.

Fifty-seven cup-cages in 56 patients were included with an average follow-up of 6.25 years (0.10 to 19.98 years). The average age of patients was 72.09 years (43 to 92 years) and 70.2% of patients were female. The five year Kaplan-Meier survival was 92.0% (95% CI 84.55 to 99.45) and the ten year survival was 80.5% (95% CI 58.35 to 102.65). There were 5 major complications that required revision of the cup-cage reconstruction (3 infections and 2 mechanical failures). There were 9 complications that required re-operation without revision of the cup-cage reconstruction (5 dislocations, 3 washouts for infection and one femoral revision for aseptic loosening).

In our hands the cup-cage reconstruction has provided a reliable tool to address pelvic discontinuity with an acceptable complication rate.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 5 - 5
23 Jun 2023
Higuera CA Villa JM Rajschmir K Grieco P Manrique-Succar J Riesgo AM
Full Access

Osteolysis, fractures, and bone destruction caused by osteomyelitis or metastasis can cause large bone defects and present major challenges during acetabular reconstruction in total hip arthroplasty. We sought to evaluate the survivorship and radiographic outcomes of an acetabular reconstruction consisting of a polyethylene liner (semi-constrained) embedded in cement filling bone defect(s) reinforced with screws and/or plates for enhanced fixation (HiRISC).

Retrospective chart review of 59 consecutive acetabular reconstructions as described above performed by 4 surgeons in a single institution (10/18/2018-1/5/2023) was performed. After radiographs and operative reports were reviewed, cases were classified following the Paprosky classification for acetabular defects. Paprosky type 1 cases (n=26) were excluded, while types 2/3 (n=33) were included for analysis. Radiographic loosening was evaluated up to latest follow-up. Mean follow-up was: 487 days (range, 20–1,539 days).

Out of 33 cases, 2 (6.1%) cases were oncological (metastatic disease) and 22 (66.7%) had deep infection diagnosis (i.e., periprosthetic joint infection [PJI] or septic arthritis). In total, 7 (21.2%) reconstructions were performed on native acetabula (3 septic, 4 aseptic). At a mean follow-up of 1.3 years, 5 (15.2%) constructs were revised: 4 due to uncontrolled infection (spacer exchange) and 1 for instability. On follow-up radiographs, only 1 non-revised construct showed increased radiolucencies, but no obvious loosening. When compared to patients with non-revised constructs, those who underwent revision (n=5) were significantly younger (mean 73.8 vs. 60.6 years, p=0.040) and had higher body mass index (24.1 vs. 31.0 Kg/m2, p=0.045), respectively. Sex, race, ethnicity, American-Society-of-Anesthesiologist classification, infection diagnosis status (septic/aseptic), and mean follow-up (449.3 vs. 695.6 days, respectively, p=0.189) were not significantly different between both groups.

HiRISC construct may be a viable short-term alternative to more expensive implants to treat large acetabular defects, particularly in the setting of PJI. Longer follow up is needed to establish long term survivorship.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 11 - 11
23 Jun 2023
Lombardi AV Alexander JS Berend KR Houserman DJ Adams JB Crawford DA
Full Access

Previous studies have reported excellent results with tapered, titanium alloy, porous plasma-sprayed components in patients undergoing uncemented primary total hip arthroplasty (THA). The purpose of this study was to examine survival and clinical results at minimum 25-year follow-up.

We reviewed all patients who underwent primary THA at our center through 1995 with a specific femoral component, the Mallory-Head Porous (MHP; Zimmer Biomet, Warsaw, IN). This device, marketed in the U.S. until December 2021, was essentially unchanged since its 1984 introduction, except the porous coating was continued circumferentially along the lateral aspect in 1987, a hydroxyapatite-coated option was offered in 1988, and an offset option was added in 1999 after the study period. Three hundred thirty-two patients (396 THA) had a minimum of 25-year follow-up. Mean age at surgery was 47.6 years (range, 21–70 years).

Mean follow-up in non-failed patients was 28.7 years (range, 25 to 37 years). There were 31 femoral revisions (7.8%): 9 infection, 3 failure of ingrowth, 5 aseptic loosening, 8 osteolysis revised well-fixed, 2 periprosthetic fracture, 2 polyethylene wear with trochanteric avulsion, 1 component breakage, and 1 malalignment well-fixed. Kaplan-Meier survival with endpoint of stem revision for all causes was 94.8% (95% CI: ±0.9%) at 36.7 years, and survival with endpoint of aseptic loosening/failure of ingrowth was 98.7% (95% CI: ±0.5) at 36.7 years. Harris hip scores improved significantly from 43 preoperatively to 76 most recently.

This tapered, titanium, porous plasma spray-coated femoral component continues to demonstrate high long-term survival with a low rate of femoral component revision for any reason or aseptic loosening/failure of ingrowth.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 46 - 46
23 Jun 2023
Mallett K Guarin S Sierra RJ
Full Access

Dual mobility (DM) components are increasingly used to prevent and treat dislocation after total hip arthroplasty (THA). Intraprosthetic dissociation (IPD) is a known rare complication of these implants and has reportedly decreased with modern implants. The purpose of this paper is to report the diagnosis and treatment of modern DM IPD.

1453 DM components were implanted between 2010 and 2021. 695 in primary and 758 in revision THA. 49 hips sustained a dislocation of the large head and 5 sustained an IPD at presentation. 6 additional IPD occurred at the time of reduction of large head. The average age was 64, 54% were female and the mean follow-up was three years. Of the 11 IPD, 8 had a history of instability, 5 had abductor insufficiency, 4 had prior lumbar fusion, and 3 were conversions from fracture.

The overall IPD incidence was 0.76%. Ten of the 11 DM IPD were missed at initial presentation or at the time of reduction, and all were discharged with presumed reduction. The mean time from IPD to surgical treatment was 3 weeks. One patient died with an IPD at 5 months. A DM head was reimplanted in six, two underwent revision of the acetabular component with exchange of DM head, and four were revised to a constrained liner. The re-revision rate was 55% at a mean 1.8 years. None of the patients who underwent cup revision required subsequent re-revision while half of the constrained liners and exchange of DM heads required re-revision.

The overall rate of DM dislocation or IPD is low. It is critical to identify an IPD on radiographs as it was almost universally missed at presentation or when it occurred iatrogenically. For patients presenting with IPD, the surgeon should consider acetabular revision and conversion to a constrained liner or a larger DM, with special attention to removing impinging structures that could increase the risk of re-dislocation.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 50 - 50
23 Jun 2023
Zagra L D'Apolito R Tonolini S Battaglia AG
Full Access

Stem loosening can be associated with a wide spectrum of bone loss and deformity that represent key factors for choosing the most appropriate revision implant. The aim of this study was to evaluate the clinical outcomes and the survivorship of a consecutive series of THA revisions using a taper rectangular cementless stem for primary implants (Alloclassic® Zweymuller®, Zimmer Warsaw US) at medium-term follow-up.

We retrospectively evaluated 113 patients (115 revisions) who underwent femoral revision with Zweymuller stem with a preoperative Paprosky I (86) or II (29) defects from January 2011 to December 2020. The mean follow up was 6 years (2–10). The median age at time of surgery was 71(41–93) with 60 males and 53 females. Osteolysis/radiolucency were observed in the following Gruen zones: I (91), II (3), III (2), VII (15), V (3), VI (1). Clinical assessment was performed by means of Harris Hip Score (HHS) and Visual Analogic Scale (VAS), whereas for the radiological analysis we used conventional x-rays of the hips. The statistical analysis was performed using Graphpad Prism v5.0 and data distribution was assessed by Shapiro-Wilk test, and Wilcoxon matched paired test was used to test the differences between preoperative and postoperative score.

9 patients were lost to fu (deceased or not available), 104 (106 hips) were evaluated. The mean HHS and VAS significantly improved at final follow-up, going from 33,84 and 5,78 preoperatively to 66,42 and 2,05 postoperatively, respectively. 28 patients (25%) showed unprogressive radiolucent lines in Gruen zones 1 and 7 with no other radiological nor clinical signs of loosening. One patient suffered from recurrence of the infection. The survivorship with stem revision as endpoint was 100%.

Alloclassic Zweymüller primary stem showed good medium-term results and survival rate in revision THA for aseptic loosening and second stages of two stage revisions.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 77 - 77
23 Jun 2023
Thomas J Ashkenazi I Lawrence KW Rozell JC Schwarzkopf R
Full Access

Patients with a high comorbidity burden (high-risk) can achieve similar improvements in quality of life compared to low-risk patients, but greater morbidity may deter surgeons from operating on these patients. Whether surgeon volume influences THA outcomes in high-risk patients has not been investigated. This study aimed to compare complication rates and implant survivorship in high-risk patients operated on by high volume (HV) and non-HV THA surgeons.

Patients with Charlson Comorbidity Index ≥ 5 and American Society of Anesthesiologist Classification of 3 or 4 undergoing primary, elective THA between 2013 and 2021 were retrospectively reviewed. Patients were separated into groups based on whether they were operated on by a HV surgeon (defined as the top 25% of surgeons at our institution by number of primary THAs per year) or a non-HV surgeon. Groups were propensity matched 1:1 to control for demographic variables. A total of 1,134 patients were included in the matched analysis. Ninety day readmissions and revisions were compared between groups, and Kaplan-Meier analysis was used to evaluate implant survivorship within the follow-up period.

Years of experience were comparable between Non-HV and HV surgeons (p=0.733). The HV group had significantly shorter surgical times (p<0.001), and shorter length of stay (p=0.009) compared to the Non-HV group. The HV group also had significantly fewer 90-day readmissions (p=0.030), all-cause revisions (p=0.023) and septic revisions (p=0.020) compared to the non-HV group at latest follow-up. The HV group had significantly greater freedom from all-cause (p=0.023) and septic revision (p=0.020) compared to the non-HV group.

High-risk THA patients have fewer 90-day readmissions, all-cause revisions, septic revisions, as well as shorter length of stay when treated by HV surgeons. THA candidates with a high comorbidity burden may benefit from referral to high-volume surgeons to reduce procedural risk and improve postoperative outcomes.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 83 - 83
23 Jun 2023
Cobb J
Full Access

The trend towards more minimal access has led to a series of instruments being developed to enable adequate access for Direct Anterior Approach (DAA) for hip arthroplasty. These include longer levers, hooks attached to the operating table and a series of special attachments to the operating table to position the leg and apply traction where necessary. The forces applied in this way may be transmitted locally, damaging muscle used as a fulcrum, or the knee and ankle joints when torque has to be applied to the femur through a boot. The arthroplasty surgeon's aim is to minimise the forces applied to both bone and soft tissue during surgery.

We surmised that the forces needed for adequate access were related to the extent of the capsular and soft tissue releases, and that they could be measured and optimised. with the aim of minimising the forces applied to the tissues around the hip.

Eight fresh frozen specimens from pelvis to mid tibia from four cadavers were approached using the DAA. A 6-axis force/torque sensor and 6-axis motion tracking sensor were attached to a threaded rod securely fastened to the tibial and femoral diaphysis. The torque needed to provide first extension, then external rotation, adequate for hip arthroplasty were measured as the capsular structures were divided sequentially.

The Zona Orbicularis (ZO) and Ischiofemoral Ligament(IFL) contributed most of the resistance to both extension (4.0 and 3.1Nm) and external rotation torque (5.8 and 3.9Nm). The contributions of the conjoint tendon (1.5 and 2.4Nm) and piriformis (1.2 and 2.3Nm) were substantially smaller.

By releasing the Zona Orbicularis and Ischiofemoral Ligament, the torque needed to deliver the femur for hip arthroplasty could be reduced to less than the torque needed to open a jar (2.9–5.5Nm).


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 84 - 84
23 Jun 2023
Devane P
Full Access

At the end of 2018, the NZ Joint Registry introduced a “Surgeon Outlier” policy, whereby each year, if an individual surgeons’ lower 95% confidence interval of their revision rate, measured in revision/100 component years(r/ocys), was above the NZ mean (0.71 r/ocys), that surgeon was required to audit their results with a nominated peer. This study investigates whether outlier surgeons also have high early (1 month and 1 year) revision rates.

In 2018, 236 surgeons performed 9,186 total hip arthroplasties in NZ. At the end of 2018, 11 surgeons received notification they were outliers. Results from all surgeons for years 2016, 2017 and 2018 were combined to form the first (pre-notification) time interval, and results from years 2019, 2020 and 2021 were combined to form the second time interval (post-notification). Outlier surgeons performed 2001 total hip replacements in the first time interval and 1947 hips in the second. Early revision rates (1 month and 1 year) of both outlier and nonoutlier surgeons for both time intervals were analysed.

Non-outlier surgeons had a consistent mean early revision rate of 0.75% at one month and 1.6% at one year for both time intervals. The 11 outlier surgeons had a higher earlier revision rate of 1.35% at one month and 2.45% at one year for the pre-notification time interval. These values reduced for the post-notification time interval to a revision rate of 1.23% for one month and 2.36% for one year.

Poor joint registry results of individual surgeons are often attributed to a poor choice of prosthesis. This study shows early revision rates of outlier surgeons, where prosthesis selection has minimal influence, are also high.

A slight improvement in early revision rates of outlier surgeons since introduction of the policy shows it is working.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 86 - 86
23 Jun 2023
Marin-Peña O
Full Access

Young patients undergoing THA or hip used. HOS and iHOT33 have demonstrated to be useful in hip preservation surgery but never used in THA.

The aim of the study was to evaluate long-term clinical outcomes with HOS and iHOT33 in hip arthroscopy and THA

We conducted a retrospective study with prospective data collection of 118 consecutive young patients (<65 y.o.) between 2008 to 2012 who underwent hip arthroscopy or THA. The mean follow-up was 12.05 years. All surgeries were done by the same senior surgeon. PROMs used were iHOT-33 and HOS preoperatively, at one year and 10 years. SPSS Statistics Grad Pack 28.0 software was used for statistical analysis

Arthroscopy Group (57 patients): Mean age 35.36 years. 55.93% were male. iHOT33 mean differential improvement was 24.43 at 1 year, 70,17% exceed MCID and 49,1% SCB. HOS mean differential improvement was 16.26 at one year. 54,38 % patients exceed MCID and 49,36% SCB. At 10 years, iHOT33 mean differential improvement was 14,36 and 12.56 for HOS. Regarding complications, 3 patients underwent THA (5.26%) and 10 (17.54%) continued with groin pain.

THA Group (61 patients): Mean age 52,54 years. 55.73% were male. Cementless THA was used in all patients with ceramic on ceramic used in 77%. iHOT33 mean differential improvement was 41,57 at 1 year. 95,08% patients exceed MCID and 85,25% SCB. HOS mean differential improvement was 16.57 points at one year. 85,25% patients exceed MCID and 81,97% SCB. At 10 years, iHOT33 mean differential improvement was 20,15 and 14.12 for HOS. Regarding complications, 1 patient underwent DAIR for infection (1.64%) and 1 dislocation with close reduction (1.64%).

iHOT33 or HOS scores should be considered to be used in young active patients after hip preserving surgery or THA, with more predictable results at long-term in THA group.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 39 - 39
23 Jun 2023
LaValva SM Lebrun DG Canoles HG Ren R Padgett DE Su EP
Full Access

Competitive dancers represent a unique patient population in the setting of hip arthroplasty given the high degree of hip strength and mobility required by their profession. We sought to determine the clinical outcomes and ability to return to competitive dance after total hip arthroplasty (THA) or hip resurfacing arthroplasty (HRA) among competitive dancers.

Active competitive dancers who underwent primary THA or HRA at a single institution with minimum one-year follow-up were included in the study. Primary outcomes included (1) the rate of return to competitive dance, (2) three PROMs (modified Harris Hip Score [mHHS], Hip Disability and Osteoarthritis Outcome Score for Joint Replacement [HOOS-JR], and Lower Extremity Activity Scale [LEAS]), and (3) post-operative complications.

Forty-nine hips in 39 patients (mean age 56±13 years; 80% female) were included. Mean follow-up was 4.9±5.1 years. Thirty-seven THAs and 12 HRAs were performed. Ninety-six percent of patients returned to competitive dance activities post-operatively. With respect to PROMs, there were statistically significant improvements in mHHS, HOOS-JR, and LEAS from baseline to ≥ 1 year post-operatively. There were complications in 9/49 (18%) hips post-operatively, five (10%) of which required revision surgery.

Active competitive dancers experienced significant improvements in functional outcome scores after THA or HRA, with a rate of return to competitive dance of 96%.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 22 - 22
23 Jun 2023
Chang J Stauffer T Grant K Jiranek W
Full Access

Surgical treatment of Hip PJI by resection of the infected implants and tissue and placement of a “spacer” which elutes antibiotic via antibiotic loaded cement is an accepted treatment option. There is some controversy over whether this “spacer” should be articulating or static. Proponents of the articulating option argue that there is improved function and maintenance of the soft tissue envelop. Critics have suggested that additional biomaterials may compromise eradication of infection. This study compares our results of the 2 treatment options.

A review of our institutional PJI database between 2016 and 2021 identified 87 patients who were treated with resection arthroplasty for unilateral total hip PJI. The cohort was analyzed for demographics and type for surgery, as well as medical comorbidities, survivorship, and treatment success.

44 patients were female, the mean age of all patients was 62. 44 patients were treated with Articulating apacers, and 43 patients treated with static spacers. There was no significant difference between ASA or Elixhauser score, and no significant difference between mortality or treatment failure.

This study did not show any difference between the patients who receive static spacers, from those who received articulating spacers, and deomstrated similar treatment success rates. From this data there does not appear to be any difference in success rates between those patients that were treated with static spacers and those that were treated with articulating spacers.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 82 - 82
23 Jun 2023
Halvorson RT Khattab K Ngwe H Ornowski J Akkaya Z Matthew RP Souza R Bird A Lotz J Vail TP Bailey JF
Full Access

Patients demonstrate distinct trajectories of recovery after THA. The purpose of this study was to assess the impact of adjacent muscle quality on postoperative hip kinematics. We hypothesized that patients with better adjacent muscle quality (less fatty infiltration) would have greater early biomechanical improvement.

Adults undergoing primary THA were recruited. Preoperative MRI was obtained and evaluated via Scoring Hip Osteoarthritis with MRI Scores (SHOMRI, Lee, 2015). Muscle quality was assessed by measuring fat fraction [FF] from water-fat sequences. Biomechanics were assessed preoperatively and six weeks postoperatively during a staggered stance sit-to-stand using the Kinematic Deviation Index (KDI, Halvorson, 2022). Spearman's rho was used to assess correlations between muscle quality and function.

Ten adults (5M, 5F) were recruited (average age: 60.1, BMI: 23.79, SHOMRI: 40.6, KDI: 2.96). Nine underwent a direct anterior approach and one a posterior approach. Preoperatively, better biomechanical function was very strongly correlated with lower medius FF (rho=0.89), strongly correlated with lower FF in the minimus (rho=0.75) and tensor fascia lata (TFL) FF (rho=0.70), and weakly correlated with SHOMRI (rho=0.29). At six weeks, greater biomechanical improvement was strongly correlated with lower minimus FF (rho=0.63), moderately correlated with medius FF (rho=0.59), and weakly correlated with TFL FF (rho=0.26) and SHOMRI (rho=0.39). Lastly, medius FF was moderately correlated with SHOMRI (rho=0.42) with negligible correlations between SHOMRI and FF in the minimus and TFL.

These findings suggest adjacent muscle quality may be related to postoperative function following THA, explaining some of the variability and supporting specialized muscle rehabilitation or regeneration therapy to improve outcomes.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 62 - 62
23 Jun 2023
Inaba Y Tezuka T Choe H Ike H
Full Access

Rotational acetabular osteotomy (RAO), one of periacetabular osteotomies, is an effective joint-preserving surgical treatment for developmental dysplasia of the hip. Since 2013, we have been using a CT-based navigation for RAO to perform safe and accurate osteotomy. CT-based navigation allows precise osteotomy during surgery but cannot track the bony fragment after osteotomy. Thus, it is an issue to achieve successful reorientation in accordance with preoperative planning. In this presentation, we introduce a new method to achieve reorientation and evaluate its accuracy.

Thirty joints in which CT-based navigated RAO was performed were included in this study. For the first 20 joints, reorientation was confirmed by tracing the lateral aspect of rotated fragment with navigation and checked if it matched with the preoperative planning. For the latter 10 joints, a new method was adopted. Four fiducial points were made on lateral side of the acetabulum in the preoperative 3-dimensional model and intraoperatively, rotation of the osteotomized bone was performed so that the 4 fiducial points match the preoperative plan.

To assess the accuracy of position of rotated fragment in each group, preoperative planning and postoperative CT were compared. A total of 24 radial reformat images of postoperative CT were obtained at a half-hour interval following the clockface system around the acetabulum. In every radial image, femoral head coverage of actual postop- and planned were measured to evaluate the accuracy of acetabular fragment repositioning.

The 4-fiducial method significantly reduced the reorientation error. Especially in the 12:00 to 1:00 position of the acetabulum, there were significantly fewer errors (p<0.01) and fewer cases with under-correction of the lateral acetabular coverage.

With the new method with 4 reference fiducials, reorientation of the acetabulum could be obtained as planned with lesser errors.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 75 - 75
23 Jun 2023
Blom A
Full Access

There is paucity of reliable data examining the treatment pathway for hip replacements over the life of the patient in terms of risk of revision and re-revisions.

We did a retrospective observational registry-based study of the National Joint Registry, using data on hip replacements from all participating hospitals in England and Wales, UK. We included data on all first revisions, with an identifiable primary procedure, with osteoarthritis as the sole indication for the original primary procedure. Kaplan-Meier estimates were used to determine the cumulative probability of revision and subsequent re-revision after primary hip replacement. Analyses were stratified by age and gender, and the influence of time from first to second revision on the risk of further revision was explored.

Between 2003, and 2019, there were 29 010 revision hip replacements with a linked primary episode. Revision rates of revision hip replacements were higher in patients younger than 55 years than in older age groups. After revision of primary total hip replacement, 21·3% (95% CI 18·6–24·4) of first revisions were revised again within 15 years, 22·3% (20·3–24·4) of second revisions were revised again within 7 years, and 22·3% (18·3–27·0) of third revisions were revised again within 3 years. After revision of hip resurfacing, 23·7% (95% CI 19·6–28·5) of these revisions were revised again within 15 years, 21·0% (17·0–25·8) of second revisions were revised again within 7 years, and 19·3% (11·9–30·4) of third revisions were revised again within 3 years. A shorter time between revision episodes was associated with earlier subsequent revision.

Younger patients are at an increased risk of multiple revisions. Patients who undergo a revision have a steadily increasing risk of further revision the more procedures they undergo, and each subsequent revision lasts for approximately half the time of the previous one.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 20 - 20
23 Jun 2023
Macheras G Papadakis S Argyrou C Kateros K
Full Access

Pre-operative definitive diagnosis of infection in painful total hip arthroplasty (THA) is not always easy to be established, making the intra-operative decision-making process crucial in management of revision hip surgery. Calprotectin is a promising point-of-care novel biomarker that has displayed high accuracy in detecting PJIs.

From November 2020 to December 2022, 105 patients with painful primary THA were treated with revision THA in 3 orthopaedic departments. Pre-operatively, 23 were considered infected and treated with two-stage revision THA. The remaining 82 were likely infected according to the 2019 EBJIS criteria. The suspicion of low-grade infection was based on clinical (rest and/or night pain), laboratory (CRP, ESR, WBC – normal or slightly elevated) and radiological evaluation (loosening). Hip aspiration under CT imaging was performed in these cases and 34 of them yielded positive culture and were treated with two-stage revision. Aspiration was ineffective in the remaining 48 cases (33 negative, 15 unsuccessful attempts). Intra-operatively, calprotectin was measured with lateral flow immunoassay test in these patients. Cases with calprotectin levels ≥ 50 mg/L were treated with 2-stage revision THA; otherwise, they were considered not-infected and one-stage revision was performed. Synovial fluid and tissue samples were collected for analysis. Implants were sent for sonication fluid cultures.

Calprotectin was positive (≥ 50 mg/L) in 27 cases and negative in 21 cases. There was 1 false negative case with positive tissue cultures. Out of the 27 positive cases, 25 had positive tissue cultures and sonication. However, 2 cases with high calprotectin levels (>200 mg/L) were not infected. The false positive result was attributed to severe metallosis. Calprotectin sensitivity was 96.2%, specificity 90.9%, PPV 92.6%, NPV 95.2%, AUC 0.935.

The results of this ongoing study indicate that calprotectin seems to be a valuable tool in facilitating the intra-operative decision-making process in cases that low-grade infection is suspected and diagnosis cannot be established pre-operatively.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 21 - 21
23 Jun 2023
Peel TN Astbury S Cheng AC Paterson DL Buising KL Spelman T Tran-Duy A Adie S Boyce G McDougall C Molnar R Mulford J Rehfisch P Solomon M Crawford R Harris-Brown T Roney J Wisniewski J de Steiger R
Full Access

There is an increasing incidence of revision for periprosthetic joint infection. The addition of vancomycin to beta-lactam antimicrobial prophylaxis in joint arthroplasty may reduce surgical site infections, however, the efficacy and safety have not been established.

This was a multicenter, double-blind, superiority, placebo-controlled trial. We randomized 4239 adult patients undergoing joint arthroplasty surgery to receive 1.5g vancomycin or normal saline placebo, in addition to standard cefazolin antimicrobial prophylaxis. The primary outcome was surgical site infection at 90-days from index surgery. Perioperative carriage of Staphylococcus species was also assessed.

In the 4113 patients included in the modified intention-to-treat population, surgical site infections occurred in 72/2069 (3.5%) in the placebo group and 91/2044 (4. 5%) in the vancomycin group (risk ratio 1.28; 95% confidence interval 0.94 to 1.73; p value 0.11). No difference was observed between the two groups for primary hip arthroplasty procedures. A higher proportion of infections occurred in knee arthroplasty patients in the vancomycin group (63/1109 [4.7%]) compared with the placebo group (42/1124 [3.7%]; risk ratio 1.52; 95% confidence interval 1.04 to 2.23; p value 0.031). Hypersensitivity reactions occurred in 11 (0.5%) patients in the placebo group and 24 (1.2%) in the vancomycin group (risk ratio 2.20; 95% confidence interval 1.08, 4.49) and acute kidney injury in 74 (3.7%) patients in the placebo group and 42 (2.1%) in the vancomycin group (risk ratio 0.57; 95% confidence interval 0.39, 0.83). Perioperative Staphylococcus aureus carriage was detected in 1089/3748 (29.1%) of patients.

This is the first randomized controlled trial examining the addition of a glycopeptide antimicrobial to standard beta-lactam surgical antimicrobial prophylaxis in joint arthroplasty. The addition of vancomycin to standard cefazolin prophylaxis was not superior to placebo for the prevention of surgical site infections in hip and knee arthroplasty surgery.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 27 - 27
23 Jun 2023
Chen K Wu J Xu L Han X Chen X
Full Access

To propose a modified approach to measuring femoro-epiphyseal acetabular roof (FEAR) index while still abiding by its definition and biomechanical basis, and to compare the reliabilities of the two methods. To propose a classification for medial sourcil edges.

We retrospectively reviewed a consecutive series of patients treated with periacetabular osteotomy and/or hip arthroscopy. A modified FEAR index was defined. Lateral center-edge angle, Sharp's angle, Tonnis angle on all hips, as well as FEAR index with original and modified approaches were measured. Intra- and inter-observer reliability were calculated as intraclass correlation coefficients (ICC) for FEAR index with both approaches and other alignments. A classification was proposed to categorize medial sourcil edges. ICC for the two approaches across different sourcil groups were also calculated.

After reviewing 411 patients, 49 were finally included. Thirty-two patients (40 hips) were identified as having borderline dysplasia defined by an LCEA of 18 to 25 degrees. Intra-observer ICC for the modified method were good to excellent for borderline hips; poor to excellent for DDH; moderate to excellent for normal hips. As for inter-observer reliability, modified approach outperformed original approach with moderate to good inter-observer reliability (DDH group, ICC=0.636; borderline dysplasia group, ICC=0.813; normal hip group, ICC=0.704). The medial sourcils were classified to 3 groups upon its morphology. Type II(39.0%) and III(43.9%) sourcils were the dominant patterns. The sourcil classification had substantial intra-observer agreement (observer 4, kappa=0.68; observer 1, kappa=0.799) and moderate inter-observer agreement (kappa=0.465). Modified approach to FEAR index possessed greater inter-observer reliability in all medial sourcil patterns.

The modified FEAR index has better intra- and inter-observer reliability compared with the original approach. Type II and III sourcils accounts for the majority to which only the modified approach is applicable.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 29 - 29
23 Jun 2023
Briem T Stadelmann VA Rüdiger HA Leunig M
Full Access

Femoroacetabular impingement is a prearthritic deformity frequently associated with early chondral damage. Several techniques exist for restoring larger cartilage defects. While AMIC proved to be an effective treatment in knee and ankle, there are only short-term data available in hip. This study aimed to investigate the mid-term clinical outcome of patients with chondral lesions treated by AMIC and evaluate the quality of repair tissue via MRI.

This retrospective, single center study includes 18 patients undergoing surgical hip dislocation for FAI between 2013 and 2016. Inclusion criteria were: cam or pincer-type FAI, femoral or acetabular chondral lesions > 1 cm2, (IRCS III-IV). Due to exclusion criteria and loss-to-follow-up 9 patients (10 hips) could be included. Patient reported outcome measures included Oxford Hip Score (OHS) & Core Outcome Measure Index (COMI)). MRIs were evaluated using the Magnetic Resonance Observation of Cartilage Repair Tissue (MOCART) score.

None of the patients underwent revision surgery except screw removals from the greater trochanter. Followup data indicate a satisfactory to good hip function at 5 years: PROMS improved from pre- to postop at 5 years: OHS from 38.1 to 43.4, COMI from to 1.8 and UCLA from 4 to 8.1 respectively. MOCART score was 67.5 postoperatively. Subgrouping showed slightly better results for acetabular defects (Ø 69.4) compared femoral defects (Ø 60).

Based on the reported mid-term results, we consider AMIC as a valuable treatment option for larger chondral defects of the hip.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 57 - 57
23 Jun 2023
Konishi T Sato T Motomura G Hamai S Kawahara S Hara D Utsunomiya T Nakashima Y
Full Access

Accurate cup placement in total hip arthroplasty (THA) for the patients with developmental dysplasia of the hip (DDH) is one of the challenges due to distinctive bone deformity. Robotic-arm assisted system have been developed to improve the accuracy of implant placement. This study aimed to compare the accuracy of robotic-arm assisted (Robo-THA), CT-based navigated (Navi-THA), and manual (M-THA) cup position and orientation in THA for DDH.

A total of 285 patients (335 hips) including 202 M-THAs, 45 Navi-THAs, and 88 Robo-THA were analyzed. The choice of procedure followed the patient's preferences. Horizontal and vertical center of rotation (HCOR and VCOR) were measured for cup position, and radiographic inclination (RI) and anteversion (RA) were measured for cup orientation. The propensity score-matching was performed among three groups to compare the absolute error from the preoperative target position and angle.

Navi-THA showed significantly smaller absolute errors than M-THA in RI (3.6° and 5.4°) and RA (3.8° and 6.0°), however, there were no significant differences between them in HCOR (2.5 mm and 3.0 mm) or VCOR (2.2 mm and 2.6 mm). In contrast, Robo-THA showed significantly smaller absolute errors of cup position than both M-THA and Navi-THA (HCOR: 1.7 mm and 2.9 mm, vs. M-THA, 1.6 mm and 2.5 mm vs. Navi-THA, VCOR:1.7 mm and 2.4 mm, vs. M-THA, 1.4 mm and 2.2 mm vs. Navi-THA). Robo-THA also showed significantly smaller absolute errors of cup orientation than both M-THA and Navi-THA (RI: 1.4° and 5.7°, vs. M-THA, 1.5° and 3.6°, vs. Navi-THA, RA: 1.9° and 5.8° vs. M-THA, 2.1° and 3.8° vs. Navi-THA).

Robotic-arm assisted system showed more accurate cup position and orientation compared to manual and CT-based navigation in THA for DDH. CT-based navigation increased the accuracy of cup orientation compared to manual procedures, but not cup position.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 60 - 60
23 Jun 2023
Yasunaga Y Ohshima S Shoji T Adachi N
Full Access

Satisfactory intermediate and long-term results of rotational acetabular osteotomy (RAO) for the treatment of early osteoarthritis secondary to developmental dysplasia of the hip have been reported. The purpose of this study is to examine the 30-year results of RAO.

Between 1987 and 1994, we treated 49 patients (55 hips) with RAO for diagnosis of pre- OA or early-stage OA. Of those patients, 35 patients (43 hips) were available at a minimum of 28 years. The follow-up rate was 78.2% and the mean follow-up was 30.5 years. The mean age at the time of surgery was 34 years. Clinical evaluation was performed with the Merle d'Aubigne and Postel rating scale, and radiographic analyses included measurements of the center-edge angle, acetabular roof angle, and head lateralization index on preoperative, postoperative AP radiographs of the pelvis. Postoperative joint congruency was classified into four grades. The radiographic evidence of progression of OA was defined as the minimum joint space less than 2.5mm.

The mean preoperative clinical score was 14.0, which improved to a mean of 15.3 at the time of the latest follow-up. The mean center-edge angle improved from 0.6° preoperatively to 34° postoperatively, the mean acetabular roof angle improved from 28.4°preoperatively to 1.0°postoperatively, the mean head lateralization index improved from 0.642 preoperatively to 0.59 postoperatively. Postoperative joint congruency was excellent in 11 hips, good in 29 hips, and fair in 3 hips. Nineteen patients (20 hips) had radiographic OA progression, and 10 patients (11 hips) were converted to THA. Kaplan-Meier survivorship analysis, with radiographic OA progression as the end point, predicted survival of 75.6% at 20 years and 48.8% at 30 years, and with THA conversion as the end point, 90.2% at 20 years and 71.2% at 30 years.

The RAO is an effective surgical procedure for symptomatic dysplastic hips of pre- and early-stage OA and could change the natural history of the dysplastic hip.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 61 - 61
23 Jun 2023
Petrie JR Nepple JJ Thapa S Schoenecker PL Clohisy JC
Full Access

The periacetabular osteotomy (PAO) is a well-described procedure for symptomatic acetabular dysplasia. For severe acetabular deformities, the efficacy of acetabular reorientation remains controversial and the literature on mid to long-term outcomes is limited. The purpose of this study was to analyze average 10-year clinical and radiographic results of the PAO for severe acetabular dysplasia.

We retrospectively analyzed a consecutive series of patients undergoing PAO for severe acetabular dysplasia as defined by LCEA < 5˚. Patient demographics, radiographic measurements, modified Harris Hip score (MHHS), UCLA activity, SF-12, and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were assessed.

Sixty-eight patients (82 hips; 54 females) with an average age 20.7 and BMI of 24.4 kg/m2 were included. Mean follow-up was follow up was 10.3 years. . The LCEA and ACEA improved a mean of 32.8˚ (8.4˚ to 24.4˚, p<0.0001) and 31.6˚ (−4.9˚ to 26.7˚, p< 0.0001), respectively. MHHS improved an average of 17.5 points (64.6 to 82.3, p<0.0001), WOMAC Pain subscore improved an average of 21.1 points (65.7 to 85.0, p = 0.004), and SF-12 physical improved 11.8 points (from 40.3 to 50.6, p = 0.006). Activity improved as indicated by a 1.5-point increase in the UCLA Activity score (6.4 to 7.9, p=0.005). Six hips (9.1%) converted to THA at average 6.8 years post-PAO. Kaplan-Meier survival analysis with THA as the endpoint was 92% at 15 years (95% confidence interval [CI] (81%–96%). Multivariable linear regression analysis revealed concurrent osteochondroplasty was associated with a decreased risk of PAO failure.

PAO is an effective treatment for severe acetabular dysplasia. At average 10.3 years, clinical and radiographic outcomes demonstrate pain relief, improved hip function, and major deformity correction. We observed minimal clinical deterioration over time.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 10 - 10
23 Jun 2023
Apinyankul R Hong C Hwang K Koltsov JCB Amanatullah DF Huddleston JI Maloney WJ Goodman SB
Full Access

Instability is a common indication for revision total hip arthroplasty (THA). However, even after the initial revision, some patients continue to have recurrent dislocations. This study investigates those at risk for recurrent dislocation after revision THA for instability at a single institution.

Between 2009 and 2019, 163 patients underwent revision THA for instability at a single institution. Thirty-three of these patients required re-revision THA due to recurrent dislocation. Cox proportional hazard models with death as a competing event were used to analyze risk factors, including prosthesis sizing and alignment. Paired t-tests or Wilcoxon signed rank tests were used to assess patient outcomes (Veterans RAND 12 (VR-12) physical score, VR-12 mental score, Harris Hip Score, and hip disability and osteoarthritis outcome score for joint replacement).

Duration of follow-up until either re-revision or final follow-up was a mean of 45.3 ± 38.2 months. The 1-year cumulative incidence for recurrent dislocation after revision was 8.7%, which increased to 19.6% at 5 years and 32.9% at 10 years postoperatively. In the multivariable analysis, high ASA score [HR 2.71], being underweight (BMI<18 kg/m2) [HR 36.26] or overweight/obese (BMI>25 kg/m2) [HR 4.31], use of specialized liners [HR 5.51–10.71], lumbopelvic stiffness [HR 6.29], and postoperative abductor weakness [HR 7.20] were significant risk factors for recurrent dislocation. Increasing the cup size decreased the dislocation risk [HR 0.89]. The dual mobility construct did not affect the risk for recurrent dislocation in univariate or multivariable analyses. VR-12 physical and HHS (pain and function) scores improved postoperatively at midterm.

Patients requiring revision THA for instability are at risk for recurrent dislocation. Higher ASA scores, abnormal BMI, use of special liners, lumbopelvic stiffness, and postoperative abductor weakness are significant risk factors for re-dislocation.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 14 - 14
23 Jun 2023
Hooper G Thompson D Frampton C Lash N Sharr J Fulkner D Gilchrist N
Full Access

Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMD.

119 patients were randomized to receive either a proximally coated dual taper wedge stem, a proximally coated anatomic stem or a fully coated collarless triple tapered stem. Dual energy x-ray absorptiometry scans (Lunar iDXA, GE Healthcare, Madison, WI) assessed BMD across the seven Gruen zones pre-operatively, and post-operatively at 6-weeks, 1-year, and 2-years comparing the unoperated contralateral femur as a control.

BMD increased in zones one (2.5%), two (17.1%), three (13.0%), five (10%) and six (17.9%) for all stems. Greater preservation of BMD was measured on the lateral cortex (zone 2) for both the dual taper wedge and anatomic stems (p = 0.019). The dual taper wedge stem also demonstrated preservation of BMD in the medial calcar (zone 7) whilst the anatomic and triple taper stem declined in this region, however this was not statistically significant (p = 0.059). BMD decreased on average by 2.1% in the mid-diaphysis region, distal to the stem tip (zone 4) for all implants. All stems performed equivalently at final follow-up in all patient reported outcome measures.

Implant design was shown to impact BMD changes. All stems preserved bone at the metaphyseal level in early follow-up, which theoretically indicates favorable implant fixation. There was no significant stress shielding observed, however longer follow-up is required to elucidate the impact of this finding on implant survivorship.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 16 - 16
23 Jun 2023
Laboudie P Hallé A Anract P Hamadouche M
Full Access

Periprosthetic femoral fracture (PFF) following primary total hip arthroplasty (THA) is of raising concern with the aging of the population. The aim of this retrospective study was to assess the incidence of early PFF associated with Charnley- Kerboull (CK) stems cemented line-to-line according to the “French paradox” principles through the anterior approach (AA) in patients older than 70 years old.

This monocentric study involved 25 surgeons with various level of experience. From a prospectively collected database, all CK stems (AmisK®, Medacta, Castel San Pietro, Switzerland) done consecutively from January 2018 to May 2022 through the AA in patients older than 70 years were included. The measured parameters included canal flare index (CFI), morphological cortical index (MCI), canal-calcar ratio (CCR), ilium-ischial ratio (IIR), ilium overhang, and anterior superior iliac spine (ASIS) to greater trochanter distance. Dorr classification was also recorded.

A total of 416 CK stems performed by 25 surgeons were included. All patients had a minimal 3-month follow-up. The mean age was 77.4 years, and the mean BMI was 25.3 kg/m2. According to the Dorr classification 240 hips were of Dorr type A, 144 Dorr type B, and 2 Dorr type C. Mean CFI, MCI, CCR, IIR and ASIS-GT were 3.8, 0.5, 2.8, 2.5, and 101mm, respectively. Amongst the 416 THAs, one (0.24%; 95% CI 0.20 – 0.28%) early PFF Vancouver type B2 fracture that occurred 24 days postoperatively was observed.

This study demonstrated that CK stems cemented according to the “French Paradox” were associated with an extremely low rate of early PFF in patients over 70 years. The observed results are better than those reported with uncemented or taper slip cemented stems. Longer follow-up is warranted to evaluate further rate of fracture that may occur during the bone remodeling process around the femoral component.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 24 - 24
23 Jun 2023
Byrd JWT Jones KS Bardowski EA
Full Access

Partial thickness abductor tendon tears are a significant source of recalcitrant laterally based hip pain. For those that fail conservative treatment, the results of endoscopic repair are highly successful with minimal morbidity. The principal burden is the protracted rehabilitation that is necessary as part of the recovery process. There is a wide gap between failed conservative treatment and successful surgical repair. It is hypothesized that a non-repair surgical strategy, such as a bioinducitve patch, could significantly reduce the burden associated recovery from a formal repair. Thus, the purpose of this study is to report the preliminary results of this treatment strategy.

Symptomatic partial thickness abductor tendon tears are treated conservatively, including activity modification, supervised physical therapy and ultrasound guided corticosteroid injections. Beginning in January 2022, patients undergoing hip arthroscopy for intraarticular pathology who also had persistently symptomatic partial thickness abductor tendon tears, were treated with adjunct placement of a bioinducitve (Regeneten) patch over the tendon lesion from the peritrochanteric space. The postop rehab protocol is dictated by the intraarticular procedure performed. All patients are prospectively assessed with a modified Harris Hip Score (mHHS) and iHOT and the tendon healing response examined by ultrasound.

Early outcomes will be presented on nine consecutive cases.

Conclusions - Will be summarized based on the preliminary outcomes to be reported.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 35 - 35
23 Jun 2023
Lavernia C Patron LP Lavernia CJ Gibian J Hong T Bendich I Cook SD
Full Access

Fracture of contemporary femoral stems is a rare occurrence. Earlier THR stems failed due to design issues or post manufacturing heat treatments that weakened the core metal. Our group identified and analyzed 4 contemporary fractured femoral stems after revision surgery in which electrochemical welds contributed to the failure.

All four stems were proximally porous coated titanium alloy components. All failures occurred in the neck region post revision surgery in an acetabular cup exchange. All were men and obese. The fractures occurred at an average of 3.6 years post THR redo (range, 1.0–6.5 years) and 8.3 years post index surgery (range, 5.5–12.0 years). To demonstrate the effect of electrocautery on retained femoral stems following revision surgery, we applied intermittent electrosurgical currents at three intensities (30, 60, 90 watts) to the polished neck surface of a titanium alloy stem under dry conditions.

At all power settings, visible discoloration and damage to the polished neck surface was observed. The localized patterns and altered metal surface features exhibited were like the electrosurgically-induced damage priorly reported.

The neck regions of all components studied displayed extensive mechanical and/or electrocautery damage in the area of fracture initiation. The use of mechanical instruments and electrocautery was documented to remove tissues in all 4 cases.

The combination of mechanical and electrocautery damage to the femoral neck and stem served as an initiation point and stress riser for subsequent fractures. The electrocautery and mechanical damage across the fracture site observed occurred iatrogenically during revision surgery. The notch effect, particularly in titanium alloys, due to mechanical and/or electrocautery damage, further reduced the fatigue strength at the fractured femoral necks. While electrocautery and mechanical dissection is often required during revision THA, these failures highlight the need for caution during this step of the procedure in cases where the femoral stem is retained.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 6 - 6
23 Jun 2023
Callary S Barends J Solomon LB Nelissen R Broekhuis D Kaptein B
Full Access

The best treatment method of large acetabular bone defects at revision THR remains controversial. Some of the factors that need consideration are the amount of residual pelvic bone removed during revision; the contact area between the residual pelvic bone and the new implant; and the influence of the new acetabular construct on the centre of rotation of the hip. The purpose of this study was to compare these variables in two of the most used surgical techniques used to reconstruct severe acetabular defects: the trabecular metal acetabular revision system (TMARS) and a custom triflanged acetabular component (CTAC).

Pre- and post-operative CT-scans were acquired from 11 patients who underwent revision THR with a TMARS construct for a Paprosky IIIB defect, 10 with pelvic discontinuity, at Royal Adelaide Hospital. The CT scans were used to generate computer models to virtually compare the TMARS and CTAC constructs using a semi-automated method. The TMARS construct model was calculated using postoperative CT scans while the CTAC constructs using the preoperative CT scans. The bone contact, centre of rotation, inclination, anteversion and reamed bone differences were calculated for both models.

There was a significant difference in the mean amount of bone reamed for the TMARS reconstructions (15,997 mm3) compared to the CTAC reconstructions (2292 mm3, p>0.01). There was no significant difference between overall implant bone contact (TMARS 5760mm2 vs CTAC 5447mm2, p=0.63). However, there was a significant difference for both cancellous (TMARS 4966mm2 vs CTAC 2887mm2, p=0.008) and cortical bone contact (TMARS 795mm2 vs CTAC 2560mm2, p=0.001). There was no difference in inclination and anteversion achieved. TMARS constructs resulted on average in a centre of rotations 7.4mm more lateral and 4.0mm more posterior.

Modelling of two different reconstructions of Paprosky IIIB defects demonstrated potential important differences between all variables investigated.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 9 - 9
23 Jun 2023
Lachiewicz PF Skalla LA Purcell KP
Full Access

Severe heterotopic ossification (grade III and IV) after contemporary total hip arthroplasty (THA) requiring excision is very uncommon. We performed a systematic review of the literature, and report a new case series with operative treatment after primary uncemented THA.

A systematic review identified papers describing patients who had excision of heterotopic ossification (HO) after contemporary THA, defined as performed after 1988. Concepts of hip arthroplasty, heterotopic ossification, and surgical excision were searched in MEDLINE, Embase, and Scopus, from database inception to November 2022. Inclusion criteria were: articles that included specific patient data on grade of heterotopic ossification, operative procedure, and prophylaxis. Studies were screened for inclusion by two independent reviewers. Extracted data included demographic data, interval from index surgery to excision, clinical results, and complications. One surgeon performed reoperation for ankylosis of primary THA in three patients with severe pain and deformity.

Seven case series or case report studies were included. There were 41 patients, with grade III or IV HO, that had excision, and in five patients, revision of a component was also performed. Perioperative prophylaxis was irradiation alone in 10 patients, irradiation and indomethacin in 10, and indomethacin alone in 21 patients. At a mean follow-up time of 14.8 months, definition of the results was not uniform, and range of motion was improved, but relief of pain was inconsistent. There was one dislocation, one gastrointestinal complication, and two recurrences. Treatment of the three patients, with wide excision of peri-articular bone, selective exchange of components, and peri-operative irradiation prophylaxis, was successful in improving motion and deformity.

There is insufficient data on the treatment of severe symptomatic HO after contemporary THA. Prophylaxis with low-dose irradiation was successful to prevent recurrence. Multicenter studies will be needed to determine the optimum timing and prognosis for treatment.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 12 - 12
23 Jun 2023
Yee AHF Chan VWK Chiu K
Full Access

Uncemented femoral components have been used in total hip arthroplasties (THAs) for over three decades. Data on long-term performance of hydroxyapatite-coated femoral stems is however limited. This study reports the survivorship of a collarless, straight, hydroxyapatite-coated femoral stem (Omnifit HA, Osteonic) with a minimum of 20 years of follow-up.

We reviewed the results of 165 THAs using Omnifit HA in 138 patients performed between August 1993 and December 1999. The mean age at surgery was 46 years (range 20 – 77 years). Avascular necrosis was the most common cause of THA, followed by ankylosing spondylitis and primary osteoarthritis. The mean follow-up was 22 years (range 20–31 years). At 20 and 25 years, 113 arthroplasties (91 patients) and 63 arthroplasties (55 patients) were available for follow-up respectively, while others had deceased or were lost to follow-up.

Kaplan-Meier survivorship analysis was performed to evaluate the survival of the femoral component. Radiographs were reviewed at regular intervals, and implant stability was evaluated using Engh classification.

Seven out of 165 stems were revised upon the latest follow-up; that included one case of aseptic loosening with revision done at 15 years, three peri-prosthetic fractures, two infections, and one recurrent dislocation.

At 20 years, survivorship with revision of the femoral stem for any cause and aseptic loosening as the endpoint was 96.0% (95% CI, 92.6 – 99.5%) and 98.4% (95% CI, 96.2 – 100%) respectively. At 25 years, the corresponding survivorship rates were 94.5% (95% CI, 91.9 – 97.3%) and 98.1% (95% CI, 95.7 – 99.6%) respectively.

Radiographic findings of stable bony fixation were seen in 86 stems (76.1%) and those of loosening in 4 stems (3.5%) at 20 years. All patients with radiographic signs of loosening were asymptomatic and did not require revision.

The Omnifit HA femoral stem offered promising long-term survivorship into the third decade.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 13 - 13
23 Jun 2023
Furnes O Lygre SHL Hallan G Fenstad AM
Full Access

The Norwegian Arthroplasty Register (NAR) started collecting data on total hip arthroplasty (THA) in 1987. Very long-term results of implants for THA are scarce. We aimed to show long-term results for the three most used femoral stems, operated from 1987.

We included the uncemented Corail femoral stem (n=66,309) and the cemented Exeter stem (n=35,050) both of which are currently in frequent use. In addition, we included the Charnley stem (n=32,578, in use until 2014). To ensure comparable conditions, stems fixated with low viscosity cement and stems revised due to infections were excluded. Differences in risk of revision (all reasons and stem revisions) were assessed with Kaplan-Meier and Cox regression analyses with adjustment for possible confounding from age, sex and diagnosis (OA, other). Stem revision was defined as a revision caused by loosening of the stem, dislocation, osteolysis in the femur, or periprosthetic femur fracture, and in which the femoral component was removed or exchanged.

The median and max follow-up for Corail, Exeter and Charnley were 6.3 (33.1), 8.0 (34.2) and 13.1 (34.3) respectively. Thirty years survival estimates for Corail, Exeter and Charnley stems were 88.6% (CI:85.8–90.9%), 86.7% (83.7–89.2%) and 87.1% (85.4–88.5%) respectively with stem revision as endpoint, and 56.1% (CI:53.1–59.1%), 73.3% (70.5–76.1%) and 80.2% (78.4–82.0%) with all THA revisions as endpoint. Compared to the Corail, the Exeter (HRR=1.3, CI:1.2–1.4) and the Charnley (HRR=1.9, CI:1.7–2.1) had a significant higher risk of stem revision. Women 75 years and older had better results with the cemented stems. Analyses accounting for competing risk from other causes of revision did not alter the findings.

The uncemented Corail stem performed well in terms of stem revisions for stem-related revision causes compared to two frequently used cemented stems with very long follow-up. The differences between the three stems were small.