Hip

THE DIAGNOSTIC ACCURACY OF INTRAOPERATIVE SYNOVIAL FLUID CALPROTECTIN IN SUSPECTED LOW-GRADE PERIPROSTHETIC HIP JOINT INFECTIONS

The International Hip Society (IHS) Closed Meeting 2023, Boston, MA, USA, 17–20 May 2023.



Abstract

Pre-operative definitive diagnosis of infection in painful total hip arthroplasty (THA) is not always easy to be established, making the intra-operative decision-making process crucial in management of revision hip surgery. Calprotectin is a promising point-of-care novel biomarker that has displayed high accuracy in detecting PJIs.

From November 2020 to December 2022, 105 patients with painful primary THA were treated with revision THA in 3 orthopaedic departments. Pre-operatively, 23 were considered infected and treated with two-stage revision THA. The remaining 82 were likely infected according to the 2019 EBJIS criteria. The suspicion of low-grade infection was based on clinical (rest and/or night pain), laboratory (CRP, ESR, WBC – normal or slightly elevated) and radiological evaluation (loosening). Hip aspiration under CT imaging was performed in these cases and 34 of them yielded positive culture and were treated with two-stage revision. Aspiration was ineffective in the remaining 48 cases (33 negative, 15 unsuccessful attempts). Intra-operatively, calprotectin was measured with lateral flow immunoassay test in these patients. Cases with calprotectin levels ≥ 50 mg/L were treated with 2-stage revision THA; otherwise, they were considered not-infected and one-stage revision was performed. Synovial fluid and tissue samples were collected for analysis. Implants were sent for sonication fluid cultures.

Calprotectin was positive (≥ 50 mg/L) in 27 cases and negative in 21 cases. There was 1 false negative case with positive tissue cultures. Out of the 27 positive cases, 25 had positive tissue cultures and sonication. However, 2 cases with high calprotectin levels (>200 mg/L) were not infected. The false positive result was attributed to severe metallosis. Calprotectin sensitivity was 96.2%, specificity 90.9%, PPV 92.6%, NPV 95.2%, AUC 0.935.

The results of this ongoing study indicate that calprotectin seems to be a valuable tool in facilitating the intra-operative decision-making process in cases that low-grade infection is suspected and diagnosis cannot be established pre-operatively.