Advertisement for orthosearch.org.uk
Results 1 - 15 of 15
Results per page:
Bone & Joint Open
Vol. 3, Issue 5 | Pages 359 - 366
1 May 2022
Sadekar V Watts AT Moulder E Souroullas P Hadland Y Barron E Muir R Sharma HK

Aims

The timing of when to remove a circular frame is crucial; early removal results in refracture or deformity, while late removal increases the patient morbidity and delay in return to work. This study was designed to assess the effectiveness of a staged reloading protocol. We report the incidence of mechanical failure following both single-stage and two stage reloading protocols and analyze the associated risk factors.

Methods

We identified consecutive patients from our departmental database. Both trauma and elective cases were included, of all ages, frame types, and pathologies who underwent circular frame treatment. Our protocol is either a single-stage or two-stage process implemented by defunctioning the frame, in order to progressively increase the weightbearing load through the bone, and promote full loading prior to frame removal. Before progression, through the process we monitor patients for any increase in pain and assess radiographs for deformity or refracture.


Bone & Joint Research
Vol. 9, Issue 3 | Pages 99 - 107
1 Mar 2020
Chang C Jou I Wu T Su F Tai T

Aims

Cigarette smoking has a negative impact on the skeletal system, causes a decrease in bone mass in both young and old patients, and is considered a risk factor for the development of osteoporosis. In addition, it disturbs the bone healing process and prolongs the healing time after fractures. The mechanisms by which cigarette smoking impairs fracture healing are not fully understood. There are few studies reporting the effects of cigarette smoking on new blood vessel formation during the early stage of fracture healing. We tested the hypothesis that cigarette smoke inhalation may suppress angiogenesis and delay fracture healing.

Methods

We established a custom-made chamber with airflow for rats to inhale cigarette smoke continuously, and tested our hypothesis using a femoral osteotomy model, radiograph and microCT imaging, and various biomechanical and biological tests.


Bone & Joint Research
Vol. 8, Issue 7 | Pages 304 - 312
1 Jul 2019
Nicholson JA Tsang STJ MacGillivray TJ Perks F Simpson AHRW

Objectives

The aim of this study was to review the current evidence and future application for the role of diagnostic and therapeutic ultrasound in fracture management.

Methods

A review of relevant literature was undertaken, including articles indexed in PubMed with keywords “ultrasound” or “sonography” combined with “diagnosis”, “fracture healing”, “impaired fracture healing”, “nonunion”, “microbiology”, and “fracture-related infection”.


Bone & Joint 360
Vol. 7, Issue 2 | Pages 2 - 7
1 Apr 2018
Das A Giddie J Ollivere B


Bone & Joint 360
Vol. 5, Issue 6 | Pages 26 - 27
1 Dec 2016


Bone & Joint 360
Vol. 5, Issue 4 | Pages 38 - 40
1 Aug 2016


Bone & Joint Research
Vol. 5, Issue 7 | Pages 287 - 293
1 Jul 2016
Ismail H Phedy P Kholinne E Djaja YP Kusnadi Y Merlina M Yulisa ND

Objectives

To explore the therapeutic potential of combining bone marrow-derived mesenchymal stem cells (BM-MSCs) and hydroxyapatite (HA) granules to treat nonunion of the long bone.

Methods

Ten patients with an atrophic nonunion of a long bone fracture were selectively divided into two groups. Five subjects in the treatment group were treated with the combination of 15 million autologous BM-MSCs, 5g/cm3 (HA) granules and internal fixation. Control subjects were treated with iliac crest autograft, 5g/cm3 HA granules and internal fixation. The outcomes measured were post-operative pain (visual analogue scale), level of functionality (LEFS and DASH), and radiograph assessment.


Bone & Joint Research
Vol. 5, Issue 4 | Pages 116 - 121
1 Apr 2016
Leow JM Clement ND Tawonsawatruk T Simpson CJ Simpson AHRW

Objectives. The radiographic union score for tibial (RUST) fractures was developed by Whelan et al to assess the healing of tibial fractures following intramedullary nailing. In the current study, the repeatability and reliability of the RUST score was evaluated in an independent centre (a) using the original description, (b) after further interpretation of the description of the score, and (c) with the immediate post-operative radiograph available for comparison. Methods. A total of 15 radiographs of tibial shaft fractures treated by intramedullary nailing (IM) were scored by three observers using the RUST system. Following discussion on how the criteria of the RUST system should be implemented, 45 sets (i.e. AP and lateral) of radiographs of IM nailed tibial fractures were scored by five observers. Finally, these 45 sets of radiographs were rescored with the baseline post-operative radiograph available for comparison. Results. The initial intraclass correlation (ICC) on the first 15 sets of radiographs was 0.67 (95% CI 0.63 to 0.71). However, the original description was being interpreted in different ways. After agreeing on the interpretation, the ICC on the second cohort improved to 0.75. The ICC improved even further to 0.79, when the baseline post-operative radiographs were available for comparison. Conclusion. This study demonstrates that the RUST scoring system is a reliable and repeatable outcome measure for assessing tibial fracture healing. Further improvement in the reliability of the scoring system can be obtained if the radiographs are compared with the baseline post-operative radiographs. Cite this article: Mr J.M. Leow. The radiographic union scale in tibial (RUST) fractures: Reliability of the outcome measure at an independent centre. Bone Joint Res 2016;5:116–121. DOI: 10.1302/2046-3758.54.2000628


Bone & Joint Research
Vol. 5, Issue 3 | Pages 101 - 105
1 Mar 2016
Wang X Luo F Huang K Xie Z

Objectives

Induced membrane technique is a relatively new technique in the reconstruction of large bone defects. It involves the implantation of polymethylmethacrylate (PMMA) cement in the bone defects to induce the formation of membranes after radical debridement and reconstruction of bone defects using an autologous cancellous bone graft in a span of four to eight weeks. The purpose of this study was to explore the clinical outcomes of the induced membrane technique for the treatment of post-traumatic osteomyelitis in 32 patients.

Methods

A total of 32 cases of post-traumatic osteomyelitis were admitted to our department between August 2011 and October 2012. This retrospective study included 22 men and ten women, with a mean age of 40 years (19 to 70). Within this group there were 20 tibias and 12 femurs with a mean defect of 5 cm (1.5 to 12.5). Antibiotic-loaded PMMA cement was inserted into the defects after radical debridement. After approximately eight weeks, the defects were implanted with bone graft.


Bone & Joint 360
Vol. 5, Issue 1 | Pages 37 - 40
1 Feb 2016
Ribbans W


Bone & Joint 360
Vol. 5, Issue 1 | Pages 2 - 8
1 Feb 2016
Bryson D Shivji F Price K Lawniczak D Chell J Hunter J


Bone & Joint 360
Vol. 4, Issue 4 | Pages 31 - 33
1 Aug 2015

The August 2015 Children’s orthopaedics Roundup360 looks at: Learning the Pavlik; MRI and patellar instability; Cerebral palsy and hip dysplasia; ‘Pick your poison’: elastic nailing under the spotlight; Club feet and surgery; Donor site morbidity in vascularised fibular grafting; Cartilage biochemistry with hip dysplasia; SUFE and hip decompression: a good option?


Bone & Joint 360
Vol. 4, Issue 4 | Pages 23 - 24
1 Aug 2015

The August 2015 Shoulder & Elbow Roundup360 looks at: Clavicular fractures are being fixed – but how?; Propionibacterium acnes: a pain in the shoulder?; Bacteria, armpits and arthroplasty; Living longer, but unhappy: the woes of shoulder arthroplasty in the under 50s; Recurrent dislocations in the adolescent population; Splinting for elbow stiffness; Revision Bankart repair


Bone & Joint 360
Vol. 2, Issue 6 | Pages 22 - 24
1 Dec 2013

The December 2013 Shoulder & Elbow Roundup360 looks at: Platelet-rich plasma; Arthroscopic treatment of sternoclavicular joint osteoarthritis; Synchronous arthrolysis and cuff repair; Arthroscopic arthrolysis; Regional blockade in the beach chair; Recurrent instability; Avoiding iatrogenic nerve injury in elbow arthroscopy; and Complex reconstruction of total elbow revisions


Bone & Joint 360
Vol. 1, Issue 1 | Pages 20 - 21
1 Feb 2012