Advertisement for orthosearch.org.uk
Results 1 - 20 of 85
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 23 - 23
2 Jan 2024
Dragonas C Waseem S Simpson A Leivadiotou D
Full Access

The advent of modular implants aims to minimise morbidity associated with revision of hemiarthroplasty or total shoulder arthroplasty (TSA) to reverse shoulder arthroplasty (RSR) by allowing retention of the humeral stem. This systematic review aimed to summarise outcomes following its use and reasons why modular humeral stems may be revised.

A systematic review of Pubmed, Medline and EMBASE was performed according to PRISMA guidelines of all patients undergoing revision of a modular hemiarthroplasty or TSA to RSR. Primary implants, glenoid revisions, surgical technique and opinion based reports were excluded. Collected data included demographics, outcomes and incidence of complications.

277 patients were included, with a mean age of 69.8 years (44-91) and 119 being female. Revisions were performed an average of 30 months (6-147) after the index procedure, with the most common reason for revision being cuff failure in 57 patients. 165 patients underwent modular conversion and 112 underwent stem revision. Of those that underwent humeral stem revision, 18 had the stem too proximal, in 15 the stem was loose, 10 was due to infection and 1 stem had significant retroversion. After a mean follow up of 37.6 months (12-91), the Constant score improved from a mean of 21.8 to 48.7. Stem revision was associated with a higher complication rate (OR 3.13, 95% CI 1.82-5.39).

The increased use of modular stems has reduced stem revision, however 40% of these implants still require revision due to intra-operative findings. Further large volume comparative studies between revised and maintained humeral stems post revision of modular implants can adequately inform implant innovation to further improve the stem revision rate.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_14 | Pages 9 - 9
10 Oct 2023
Aithie J Robinson P Butcher R Denton M Simpson A Messner J
Full Access

Patellofemoral instability (PFI) is a common cause of knee pain and disability in the paediatric population. Patella alta, lateralised tibial tubercle, medial patellofemoral ligament (MPFL) deficiency, genu valgum and trochlear dysplasia are well known risk factors.

A prospective database was created including patients referred through our physiotherapy pathway following first-time patella dislocation. Patella alta and lateralisation of the tibial tuberosity was treated with a Fulkerson-type tibial tubercle osteotomy(TTO). Medial patellofemoral ligament was reconstructed using quads tendon autograft pull-down technique. A modified Sheffield protocol was used postoperatively allowing weightbearing in a hinged knee brace.

Forty patients were identified with 8 patients having bilateral presentations. Male to female ratio was 12:28 with an age range of 4–17 years. Eight patients had congenital PFI, five patients acquired PFI through traumatic patella dislocation and twenty-seven patients developed PFI from recurrent dislocations. Structural abnormalities were found in 38(95%) of patients. Patella alta (Caton-Deschamps index >1.2) was identified in 19(47%) patients, genu valgum in 12(30%) patients, increased tibial tubercle-trochlear groove distance(TT-TG>20mm) was present in 9(22.5%) patients and persistent femoral anteversion(> 20 deg) in 7(17%) patients.

Eight patients were treated with TTO and MPFL reconstruction, three patients with MPFL reconstruction alone and five patients had guided growth for genu valgum correction. Ten patients are awaiting surgery. No postoperative patients had recurrence of PFI at their latest follow up.

PFI is a common problem in the adolescent paediatric population with identifiable structural abnormalities. Correcting structural pathology with surgery leads to predictable and safe outcomes.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 30 - 30
23 Feb 2023
Abdul NM Raymond A Finsterwald M Malik S Aujla R Wilson H Dalgleish S Truter P Giwenewer U Simpson A Mattin A Gohil S Ricciardo B Lam L D'Alessandro P
Full Access

Traditionally, sports Injuries have been sub-optimally managed through Emergency Departments (ED) in the public health system due to a lack of adequate referral processes. Fractures are ruled out through plain radiographs followed by a reactive process involving patient initiated further follow up and investigation. Consequently, significant soft tissue and chondral injuries can go undiagnosed during periods in which early intervention can significantly affect natural progression. The purpose of this quality improvement project was to assess the efficacy of an innovative Sports Injury Pathway introduced to detect and treat significant soft tissue injuries.

A Sports Injury Pathway was introduced at Fiona Stanley Hospital (WA, Australia) in April 2019 as a collaboration between the ED, Physiotherapy and Orthopaedic Departments. ED practitioners were advised to have a low threshold for referral, especially in the presence of a history of a twisting knee injury, shoulder dislocation or any suggestion of a hip tendon injury. All referrals were triaged by the Perth Sports Surgery Fellow with early follow-up in our Sports Trauma Clinics with additional investigations if required. A detailed database of all referrals was maintained, and relevant data was extracted for analysis over the first 3 years of this pathway.

570 patients were included in the final analysis. 54% of injuries occurred while playing sport, with AFL injuries constituting the most common contact-sports injury (13%). Advanced Scope Physiotherapists were the largest source of referrals (60%). A total of 460 MRI scans were eventually ordered comprising 81% of total referrals. Regarding Knee MRIs, 86% identified a significant structural injury with ACL injuries being the most common (33%) followed by isolated meniscal tears (16%) and multi-ligament knee injuries (11%). 95% of Shoulder MRI scans showed significant pathology. 39% of patients required surgical management, and of these 50% were performed within 3 months from injury.

The Fiona Stanley Hospital Sports Injury Pathway has demonstrated its clear value in successfully diagnosing and treating an important cohort of patients who present to our Emergency Department. This low threshold/streamlined referral pathway has found that the vast majority of these patients suffer significant structural injuries that may have been otherwise missed, while providing referring practitioners and patients access to prompt imaging and high-quality Orthopaedic sports trauma services. We recommend the implementation of a similar Sports Injury Pathway at all secondary and tertiary Orthopaedic Centres.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 6 - 6
10 Feb 2023
Lawless A Ebert J Edwards P Aujla R Finsterwald M Dalgleish S Malik S Raymond R Giwnewer U Simpson A Grant M Leys T D'Alessandro P
Full Access

Hamstring grafts have been associated with reduced strength, donor site pain and muscle strains following Anterior Cruciate Ligament Reconstruction (ACLR). Traditional graft fixation methods required both semitendinosus and gracilis tendons to achieve a graft of sufficient length and diameter, but newer techniques allow for shorter, broad single tendon grafts.

This study seeks to compare the outcomes between Single Tendon (ST) and Dual Tendon (DT) ACLR, given there is no prospective randomised controlled trial (RCT) in the literature comparing outcomes between these options.

In this ongoing RCT: (ANZ Clinical Trials Registry ACTRN126200000927921) patients were recruited and randomised into either ST or DT groups. All anaesthetic and surgical techniques were uniform aside from graft technique and tibial fixation. 13 patients were excluded at surgery as their ST graft did not achieve a minimum 8mm diameter. 70 patients (34 ST, 36DT) have been assessed at 6 months, using PROMS including IKDC2000, Lysholm and Modified Cincinnati Knee, visual analog scale for pain frequency (VAS-F) and severity (VAS-S), dedicated donor site morbidity score, KT-1000 assessment, and isokinetic strength.

Graft diameters were significantly lesser in the ST group compared to the DT group (8.44mm/9.11mm mean difference [MD],-0.67mm; P<0.001). There was a significant and moderate effect in lower donor site morbidity in the ST group compared to the DT group (effect size [ES], 0.649; P = .01). No differences between groups were observed for knee laxity in the ACLR limb (P=0.362) or any of the patient-reported outcome measures (P>0.05). Between-group differences were observed for hamstrings strength LSI favouring the ST group, though these were small-to-moderate and non-significant (ES, 0.351; P = .147).

ST (versus DT) harvest results in significantly less donor site morbidity and this is the first prospective RCT to determine this. There were no differences between ST and DT hamstring ACLR were observed in PROMs, knee laxity and hamstring strength. Younger female patients tend to have inadequate single tendon size to produce a graft of sufficient diameter, and alternative techniques should be considered. Further endpoints include radiological analysis, longer term donor site morbidity, revision rates and return to sport and will continue to be presented in the future.


Bone & Joint Research
Vol. 11, Issue 8 | Pages 585 - 593
1 Aug 2022
Graham SM Jalal MMK Lalloo DG Hamish R. W. Simpson A

Aims

A number of anti-retroviral therapies (ART) have been implicated in potentially contributing to HIV-associated bone disease. The aim of this study was to evaluate the effect of combination ART on the fracture healing process.

Methods

A total of 16 adult male Wistar rats were randomly divided into two groups (n = eight each): Group 1 was given a combination of Tenfovir 30 mg, Lamivudine 30 mg, and Efavirenz 60 mg per day orally, whereas Group 2 was used as a control. After one week of medication preload, all rats underwent a standardized surgical procedure of mid-shaft tibial osteotomy fixed by intramedullary nail with no gap at the fracture site. Progress in fracture healing was monitored regularly for eight weeks. Further evaluations were carried out after euthanasia by micro-CT, mechanically and histologically. Two blinded orthopaedic surgeons used the Radiological Union Scoring system for the Tibia (RUST) to determine fracture healing.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_6 | Pages 2 - 2
1 Jun 2022
Yapp L Clement N Moran M Clarke J Simpson A Scott C
Full Access

This study aims to determine the lifetime risk of revision surgery after primary knee arthroplasty (KA).

The Scottish Arthroplasty Project dataset was utilised to identify all patients undergoing primary KA during the period 1998–2019. The cumulative incidence function for revision and death was calculated and adjusted analyses utilised cause-specific Cox regression modelling to determine the influence of patient-factors. The lifetime risk was calculated for patients aged between 45–99 years using multiple decrement lifetable methodology.

The lifetime risk of revision ranged between 32.7% (95% Confidence Interval (CI) 22.62–47.31) for patients aged 45–49 years and 0.63% (95%CI 0.1–4.5) for patients aged over 90 years. Adjusted analyses demonstrated the converse effect of age on revision (Hazard Ratio (HR) 0.5, 95%CI 0.5–0.6) and death (HR 3.5, 95%CI 3.4–3.7). Male sex was associated with increased risks of revision (HR 1.1, 95%CI 1.1–1.2) and death (HR 1.4, 95%CI 1.3–1.4). Patients with inflammatory arthropathy had a higher risk of death (HR 1.7, 95%CI 1.7–1.8), but were less likely to be revised (HR 0.85, 95%CI 0.74–0.98) than those treated for osteoarthritis. Patients with greater number of comorbidities and greater levels of socio-economic deprivation were at increased risk of death, but neither increased the risk of revision.

The lifetime risk of revision knee arthroplasty varies depending on patient sex, age at surgery and underlying diagnosis. Patients aged between 45 and 49 years have a one in three probability of revision surgery within their lifetime. Conversely, patients aged 90 years or over were very unlikely to experience revision.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_1 | Pages 1 - 1
1 Jan 2019
Tsang S Gwynne P Gallagher M Simpson A
Full Access

Staphylococcus aureus is responsible for 60–70% infections of surgical implants and prostheses in Orthopaedic surgery, costing the NHS £120–200 million per annum. Its ability to develop resistance or tolerance to a diverse range of antimicrobial compounds, threatens to halt routine elective implant surgery. One strategy to overcome this problem is to look beyond traditional antimicrobial drug therapies and investigate other treatment modalities. Biophysical modalities, such as ultrasound, are poorly explored, but preliminary work has shown potential benefit, especially when combined with existing antibiotics.

Using a methicillin-sensitive S. aureus reference strain and the dissolvable bead assay, biofilms were challenged by a low-intensity ultrasound (1.5MHz, 30mW/cm2, pulse duration 200µs/1KHz) for 20 minutes and gentamicin. The outcome measures were colony-forming units/mL (CFU/mL) and the minimum biofilm eradication concentration (MBEC) of gentamicin. The mean number of S. aureus within control biofilms was 1.04 × 109 CFU/mL. There was no clinically or statistically significant (p=0.531) reduction in viable S. aureus following ultrasound therapy alone. The MBEC of gentamicin for this S. aureus strain was 256 mg/L. The MBEC of gentamicin with the addition of ultrasound was 64mg/L. Further studies confirmed that the mechanism of action was due to incomplete disruption of the extracellular matrix with subsequent metabolic stimulation of the dormant biofilm-associated bacteria due to increased nutrient availability and oxygen tension.

Low intensity pulsed ultrasound was associated with a 4-fold reduction in the effective biofilm eradication concentration of gentamicin; bringing the MBEC of gentamicin to within clinically achievable concentrations.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 88 - 88
1 Nov 2018
Griffin MTA Simpson A Hamilton D
Full Access

The first three months following Total Knee Arthroplasty (TKA) provide an early window into a patient's functional outcomes, with the change of function in this time yielding valuable insight.

20 patients due to undergo primary TKA were recruited to the study. Data were recorded at three time points; pre-assessment clinic (PAC) before the operation, 6-weeks-post-operation (6WKs), at 12-weeks-post-operation (12WKs). Functional activity levels were monitored during early post-operative recovery for changes in early functional outcome, and allowed a comparison of metrics at each time point. This included direct functional testing of power output, timed functional performance in clinic, patient reported outcome measures, and multiday activity monitoring devices. Maximal power output symmetry (Power) was similar at 6WKs vs PAC (p = 0.37). At 12WKs, it had increased (p < 0.05). Timed functional performance (Performance) remained similar across all three time points (p = 0.27). Patient reported activities of daily living (ADL) performance significantly increased at 6WKs vs PAC (p < 0.05). At 12WKs, it remained similar (p = 0.10). Patient daily step count significantly decreased at 6WKs vs PAC (p < 0.05). By 12WKs, this had increased to similar levels to PAC (p = 0.30). Within the functional outcome measures, strong post-operative correlations were observed between Power and Performance (r = 0.62), Power and ADL (r = 0.49), and Performance and ADL (r = 0.61). Despite reduced measured step count and similar functional performance, patients report improved ADL at 6WKs. When symmetrical power output and measured step count have improved at 12WKs, patients report similar ADL to that at 6WKs. Multiple measures are required to get a full picture, however this highlights the different aspects measured by different tools.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 7 - 7
1 May 2018
Tsang S Mills L Frantzias J Baren J Keating J Simpson A
Full Access

Aim

The aim of this study was to determine whether the absence of periosteal reaction on plain radiographs was predictive of exchange nail failure in lower limb diaphyseal fracture non-unions.

Methods

A consecutive cohort of 20 femora and 35 tibiae undergoing exchange nailing for diaphyseal aseptic (n=39) and septic (n=16) fracture non-union at a single centre from 2003 to 2010. Multiple causes of non-union were found in 29 patients (53%) with infection present in 16 cases (29.1%). Of this cohort 49 fracture non-unions had complete radiographic records (19 femora and 30 tibiae) allowing evaluation of the periosteal callus. The primary outcome was the number of number of revision procedures required to achieve union. Failure was defined was as the requirement of >two revision procedures to achieve union.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_19 | Pages 3 - 3
1 Nov 2017
Tsang S McHugh M Guerendiain D Gwynne P Boyd J Walsh T Laurenson I Templeton K Simpson A
Full Access

Nasal carriers of methicillin sensitive Staphylococcus aureus (MSSA) have an increased risk for health-care associated infections. There is currently no national screening policy for the detection of MSSA in the UK. This study aimed to: evaluate the diagnostic performance of molecular and culture techniques in MSSA screening, determine the cause of any discrepancy between the diagnostic techniques, and model the potential effect of different diagnostic techniques on MSSA detection in orthopaedic patients. Paired nasal swabs for PCR assay and culture of S. aureus were collected from a study population of 273 orthopaedic outpatients due to undergo joint replacement surgery.

The prevalence of MSSA nasal colonisation was found to be between 22.4–35.6%. The current standard direct culturing methods for detecting S. aureus significantly underestimated the prevalence (p=0.005), failing to identify its presence in ∼1/3 of patients undergoing joint replacement surgery.

Modelling these results to national surveillance data, it was estimated that 800–1200 MSSA surgical site infections could be prevented annually in the UK by using alternative diagnostic methods to direct culture in pre-operative MSSA screening and eradication programmes.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_19 | Pages 5 - 5
1 Nov 2017
Mackenzie S Wallace R White T Murray A Simpson A
Full Access

Kirschner wires are commonly used in paediatric fractures, however, the requirement for removal and the possibility of pin site infection provides opportunity for the development of new techniques that eliminate these drawbacks. Bioabsorbable pins that remain in situ and allow definitive closure of skin at the time of insertion could provide such advantages.

Three concurrent studies were performed to assess the viability of bioabsorbable pins across the growth plate. (1) An epidemiological study to identify Kirschner wire infection rates. (2) A mechanical assessment of a bioabsorbable pin compared to Kirschner wires in a simulated supracondylar fracture. (3) The insertion of the implants across the physis of sheep to assess effects of the bioabsorbable implant on the growth plate via macroscopic, pathohistological and micro-CT analysis.

An infection rate of 8.4% was found, with a deep infection rate of 0.4%. Mechanically the pins demonstrated comparable resistance to extension forces (p=) but slightly inferior resistance to rotation (p=). The in vivo component showed that at 6 months: there was no leg length discrepancy (p=0.6), with micro-CT evidence of normal physeal growth without tethering, and comparable physeal width (p=0.3).

These studies combine to suggest that bioabsorbable pins do not represent a threat to the growth plate and may be considered for physeal fracture fixation.


The aims of the study were primarily to establish the overall success of debridement, antibiotics and implant retention (DAIR) in the management of infected total hip replacements (THRs) and secondarily to identify risk factors for failure.

Using a standardised and recognised study protocol (“Meta-analysis of observational studies in epidemiology (MOOSE) guidelines) a systematic review and meta-analysis of the literature was performed. The primary outcome measure of interest was treatment success. The search strategy and inclusion criteria plus quality assessment yielded 39 articles eligible for analysis.

The proportion of success from the literature following DAIR in the management of infected THRs is improving over time – the pooled mean proportion of success is 84.5% in studies from 2011–15. There was improved success with early debridement (75.7%) compared with delayed debridement (48.1%) (p=0.006).

The reported outcomes following DAIR appear to be improving with time. One of the most influential determinants of outcome is timing of debridement from onset of symptoms.

Surgeons should have a low threshold for investigating deep infection when presented with an acutely symptomatic THR and be aware of the updated reported outcomes associated with DAIR when considering management options.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 87 - 87
1 Apr 2017
Simpson A Dattani R Sankey R
Full Access

Background

Radiological and clinical results of total shoulder arthroplasty are dependent upon ability to accurately measure and correct glenoid version. There are a variety of imaging modalities and computer-assisted reconstruction programmes that are employed with varying degrees of success. We have compared three freely available modalities: unformatted 2D CT; formatted 2D CT; and 3D CT reconstructions.

Methods

A retrospective analysis of 20 shoulder CT scans was performed. Glenoid version was measured at the estimated mid-point of the glenoid from unformatted 2D CT scans (Scapula body method) and again following formatting of 2D CT scans in the plane of the scapula (Friedman method). 3D scapula reconstructions were also performed by downloading CT DICOM images to OSIRIX 6 and plotting ROI points on Friedman's axis to most accurately define glenoid version. Both measurements taken from 2D CT were compared to those from 3D CT. Eleven CT scans were of male patients, 9 female. Mean age was 55.2 years (Range: 23–77 years). Fourteen scans were performed for trauma, 6 for arthroplasty. Twelve scans were of the left shoulder.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 43 - 43
1 Oct 2016
Hamilton D Giesinger K Giesinger J Loth F Simpson A Howie C
Full Access

Obese patients undergoing total knee arthroplasty (TKA) face increased risks of complications such as joint infection and early revision. However, the influence of obesity on measures of patient function following TKA is poorly defined.

Knee arthroplasty outcome data for procedures carried out over an eight month period was extracted from a regional database in the UK. We analysed the impact of weight categories (BMI<30, BMI=30–34.9, and BMI≥35) on the Forgotten Joint Score – 12 (FJS-12) and Oxford Knee Score (OKS). Data was available preoperatively and 12 months postoperatively. Physical and mental health was assessed with the SF-12 one year after surgery.

Data from 256 patients were available. 49.6% had a BMI<30, 27.4% had a BMI 30–34.9 and 23.1% had a BMI≥35. Mean FJS-12 results at 1-year were 48.7 points for patients with a BMI<30, 40.7 points for patients with a BMI=30–34.9 and 34.0 points for patients with a BMI≥35. Effect sizes for change from baseline to 12-month post-op were 3.0 (Cohen's d) in patients with BMI<30 and d=2.2 in patients with BMI≥35. Mean OKS results at 1 year were 36.9 (BMI<30), 33.7 (BMI=30–34.9) and 32.0 (BMI≥35) respectively. Effect sizes for change from baseline to 12-month was d=2.1 (BMI<30) and d=1.9 (BMI≥35). Differences between BMI groups with regard to post-operative change were statistically significant for the FJS-12 (p=0.038) but not for the OKS (p=0.229).

This study highlights that outcome scores may differ in their ability to capture the impact of obesity on patient function following TKA. The FJS-12 showed significant differences in outcome based on patient obesity category, whereas the OKS did not detect between group differences.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 32 - 32
1 Oct 2016
Hamilton D Gaston P Simpson A
Full Access

Physical outcome following total knee arthroplasty is variable. Satellite cells are undifferentiated myogenic precursors considered to be muscle stem cells. We hypothesised that; the recovery of muscle strength and physical function following knee arthroplasty would be influenced by the underlying number of muscle satellite cells.

16 patients provided a distal quadriceps muscle biopsy at time of surgery. Satellite cells were identified with a primary mouse antibody for Pax7 – a cytoplasmic protein marker, and the myonuclei with DAPI. Positive cells were identified on the basis of immunofluorescent staining in association with nuclear material, and confirmed by position under the basal lamina. Patient function was assessed using a validated physical assessment protocol, the Aggregated Locomotor Function (ALF) score, muscle strength assessed using the leg extensor power-rig, and clinical outcome assessed with the Oxford Knee Score (OKS) pre-operatively and at 1 year post operatively.

Muscle satellite cell content varied amongst the patient group (Positive Staining Index 3.1 to 11.4). Satellite cell content at time of surgery correlated with change in outcomes between pre-operative and 1 year assessments in all assessed parameters (ALF, r = 0.31; muscle power, r = 49; OKS, r = 0.33). Regression analysis employing a forward stepwise selection technique employed satellite cell volume in models of pre-operative to 1 year change for all outcome parameters. Physical function (satellite cell content, patient age and pre-operative ALF score) adjusted R2 = 0.92; Muscle power (pre-operative power and satellite cell content) adjusted R2 = 0.38; Clinical outcome (pre-operative OKS and satellite cell content) adjusted R2 = 0.28.

Muscle satellite cell content influences recovery of muscle power and physical function following total knee arthroplasty. Importantly it is also associated with change in clinical scores; suggesting it to be a biomarker for patient outcomes.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 19 - 19
1 Oct 2016
Griffin M Annan J Hamilton D Simpson A
Full Access

3D imaging is commonly employed in the surgical planning and management of bony deformity. The advent of desktop 3D printing now allows rapid in-house production of specific anatomical models to facilitate surgical planning. The aim of this pilot study was to evaluate the feasibility of creating 3D printed models in a university hospital setting.

For requested cases of interest, CT DICOM images on the local NHS Picture Archive System were anonymised and transferred. Images were then segmented into 3D models of the bones, cleaned to remove artefacts, and orientated for printing with preservation of the regions of interest. The models were printed in polylactic acid (PLA), a biodegradable thermoplastic, on the CubeX Duo 3D printer.

PLA models were produced for 4 clinical cases; a complex forearm deformity as a result of malunited childhood fracture, a pelvic discontinuity with severe acetabular deficiency following explantation of an infected total hip replacement, a chronically dislocated radial head causing complex elbow deformity as a result of a severe skeletal dysplasia, and a preoperative model of a deficient proximal tibia as a result of a severe tibia fracture. The models materially influenced clinical decision making, surgical intervention planning and required equipment. In the case of forearm an articulating model was constructed allowing the site of impingement between radius and ulnar to be identified, an osteotomy was practiced on multiple models allowing elimination of the block to supination. This has not previously been described in literature. The acetabulum model allowed pre-contouring of a posterior column plate which was then sterilised and eliminated a time consuming intraoperative step.

While once specialist and expensive, in house 3D printing is now economically viable and a helpful tool in the management of complex patients.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_17 | Pages 2 - 2
1 Dec 2015
Murray I Gonzalez Z West C Miranda-Carboni G Simpson A Corselli M Péault B
Full Access

Mesenchymal stem cells (MSCs) reside around blood vessels in all organs. This reservoir of progenitors can be ‘recruited’ in response to injury. The ability to manipulate stem cells therapeutically within injured tissue provides an attractive alternative to transplantation. Stem cells are regulated by neighbouring cells. We hypothesized that endothelial cells (ECs) influence MSC differentiation into bone and fat.

MSCs were sorted from fat using fluorescent activated sorting. Their capacity to differentiate into bone, fat and cartilage was used to confirm MSC phenotype. MSCs and ECs were cultured in two-dimensions (standard culture dishes) and three-dimensions (vascular networks suspended in gel). Cocultures were exposed to osteogenic and adipogenic media. The role of EC-released factors on MSC differentiation was determined using a system in which cells share media but do not contact. Wnt pathway modulators were used to investigate the role of Wnt signalling.

MSCs differentiated into bone, fat and cartilage. MSCs and ECs integrated in two- and three-dimensions. MSCs and ECs formed vessel-like structures in three-dimensions. When cultured with ECs, MSC differentiation to bone was accelerated while differentiation to fat was inhibited. This effect on osteogenesis was maintained when cells shared media but did not contact. Coculture with Wnt modulators confirmed that this effect is in part, mediated through Wnt signalling.

Our data suggest that ECs influence MSC differentiation. Therapeutic targeting of EC-MSCs signalling may enable manipulation of MSCs in vivo avoiding the need for cell transplantation. This could enable trauma and orthopaedic patients who have healthy resident stem cells to self-repair.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_17 | Pages 7 - 7
1 Dec 2015
Clement N MacDonald D Burnett R Simpson A Howie C
Full Access

This study assessed whether patient satisfaction with their hospital stay influences the early outcome of total knee replacement (TKR).

During a five year period patients undergoing primary TKR at the study centre had prospectively outcome data recorded (n=2264). Patients with depression (p=0.04) and worse mental wellbeing (p<0.001), according to the short form (SF)-12, were more likely to be dissatisfied with their hospital stay. Decreasing level of satisfaction with their hospital stay was associated with a significantly worse post-operative OKS (p<0.001) and SF-12 score (p<0.001). Multivariable regression analysis confirmed that the patients perceived level of satisfaction with their hospital stay was an independent predictor of change in the OKS (p<0.001) and SF-12 score (p<0.001) after adjusting for confounding variables. Patient satisfaction with their TKR was significantly influenced by their hospital experience, decreasing from 96% in those with an excellent experience to 42% in those with a poor experience. Food, staff/care, and the hospital environment were the most frequent reasons of why patients rated their hospital experience as fair or poor.

A patient's perception of their inpatient hospital experience after surgery is an important modifiable predictor of early functional outcome and satisfaction with TKR.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_4 | Pages 8 - 8
1 May 2015
Tsang S Mills L Frantzias J Baren J Keating J Simpson A
Full Access

The aim of this study was to identify risk factors for failure of exchange nailing for femoral diaphyseal fracture non-unions. The study cohort comprised 40 patients with femoral diaphyseal non-unions treated by exchange nailing. The main outcome measures were union, number of secondary fixation procedures required to achieve union and time to union. Univariate analysis and multiple regression were used to identify risk factors for failure to achieve union.

The mean age of the patients at exchange nail surgery was 37 years. The median time to exchange nailing from primary fixation was 8.4 months. Multiple causes for non-union were found in 14 (35.0%) cases, with infection present in 12 (30.0%) patients. Further exchange procedures were required in nine (22.5%) cases, one patient (2.5%) required the use of another fixation modality, to achieve union. Union was ultimately achieved in 35 (94.5%) patients. The median time to union was 9.4 months after the exchange nail procedure. Univariate analysis confirmed that cigarette smoking and infection were predictive of failure (p<0.05). Multi-regression analysis found that Gustilo-Anderson grade, presence of dead bone or a gap and infection were predictive of exchange nail failure (p <0.05).

Exchange nailing is an effective treatment for aseptic femoral diaphyseal fracture non-union. Patients with infection required more than one procedure. Smoking, infection and the presence of dead-bone or a gap at the fracture site were associated with an increased risk of further fixation surgery.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_4 | Pages 12 - 12
1 May 2015
Murray I Hardy W West C Zhang X James A Soo C Simpson A Peault B
Full Access

Adipose tissue is an attractive source of mesenchymal stem cells (MSCs) as it is largely dispensable and readily accessible through minimally invasive procedures such as lipoaspiration. Until recently MSCs could only be isolated in a process involving ex-vivo culture. Pericytes (CD45−, CD146+, and CD34−) and adventitial cells (CD45−, CD146−, CD34+) represent two populations of MSCs (collectively termed perivascular stem cells or PSCs) that can be prospectively purified using fluorescence activated cell sorting (FACS). We performed FACS on lipoaspirate samples from n=129 donors to determine the frequency and yield of PSCs and to establish patient and processing factors that influence yield.

The mean number of stromal vascular fraction (SVF) cells from 100ml of lipoaspirate was 37.8×106. Within the SVF, mean cell viability was 82%, with 31.6% of cells being heamatopoietic (CD45+). Adventitial cells and pericytes represented 31.6% and 7.9% of SVF cells respectively. As such, 200ml of lipoaspirate would theoretically yield 24.5 million MSCs –a sufficient number to enable point-of-care delivery for use in several orthopaedic applications. The yield and prevalence of PSCs were minimally affected by donor age, sex and BMI. Storing lipoaspirate samples for up to 72 hours prior to processing had no significant deleterious effects on MSC yield or viability.

Our study confirms that pure populations of MSC-precursors (PSCs) can be prospectively isolated from adipose tissue, in sufficient quantities to negate the necessity for culture expansion while widening possible applications to include trauma, where a time delay between extraction and implantation excludes their use.