Proper acetabular cup placement is very important factor for successful clinical results in total hip arthroplasty (THA). Malposition of acetabular cup has been linked to increased rates of dislocation, impingement, pelvic osteolysis, cup migration, leg length discrepancy and polyethylene wear. Recently, some authors reported usefulness of navigation systems to set the acetabular cups with correct position. The purpose of this study is to evaluate the accuracy of acetabular cup placement in THA using computed tomography (CT)-based navigation system. Subjects were 235 hip joints we performed primary THA using CT based navigation system (Stryker® Navigation System, Stryker Corporation, Kalamazoo, MI, USA) from 2008 to 2014 and could assess the implant position by postoperative CT images. Their average age was 65.1 years (range 35–88). In all cases, non-cemented acetabular cups were implanted. TriAD cups (Stryker®) were used in 31 hips, and Tritanium cups (Stryker®) were used in 15 hips, and Trident cups (Stryker®) were used in 189 hips. Registration in this navigation system used surface matching system. We designed cup implantation using preoperative CT images and 3-dimensional (3-D) templates. The planned position of acetabular cup was in principle 40 degrees of inclination and 20 degrees of anteversion. However, we adjusted the better position of the cups according to pelvic tilt and femoral neck anteversion. When we placed acetabular cups, the position, inclination and anteversion, were measured by navigation system. After surgery, the positions of the cups were measured using postoperative CT images, navigation software and 3-D templates. Postoperative position using CT images were adjusted according to preoperative pelvic plane. The discrepancies between intraoperative navigation data and postoperative CT images data were analyzed as accuracy of navigation system in cup placement.Introduction
Material and Methods
Flexion contracture sometimes occurs after primary total knee arthroplasty (TKA). In most cases, flexion contracture after TKA gradually improves over time. However, some severe cases require manipulation or revision surgery. We searched our clinical database for patients who underwent primary TKA at our institution between 2008 and 2015. By reviewing patient records, we identified three patients (one man and two women) with a severe flexion contracture 30° after primary TKA. Although all three patients gained more than 120° in flexion intraoperatively, they developed flexion contracture after discharge from our institution. We performed manipulation under anaesthesia (MUA) for all three cases several months later. The two female patients had improved range of motion (ROM) right after the manipulation. However, one of them regained flexion contracture 1 year after the MUA. We report the details of the male patient, who had the worst flexion contracture (−60°). An 80-year-old man had right knee osteoarthritis. His history indicated only hypertension. The right knee ROM before the TKA was −20° extension and 135° flexion. His radiographs showed advanced-stage osteoarthritis. We performed cemented TKA (posterior stabiliser design). Three weeks after the operation, his right knee pain improved. The right knee ROM was −10° extension and 100° flexion just before discharge. However, he returned to our institution because of right knee pain and flexion contracture 31 months after the surgery. The flexion contracture gradually worsened without any trauma. When he returned, the right knee ROM was −60° extension and 135° flexion. Manipulation under general anaesthesia was not effective. Therefore, we performed revision TKA immediately. We excised the scar tissue of the posterior knee joint. Then, we shortened the distal femoral end by 1 cm and reduced the size of the femoral component. After the operation, the right knee ROM was improved to −10° flexion and 130° extension. The reported prevalence of stiffness after TKA was from 1.3% to 13%. Although the deleterious effects of persistent flexion contractures > 15° is well understood, whether they resolve with time or need surgical intervention is controversial. MUA is generally the initial option for patients with flexion contractures, with the possibility of some improvement. If severe flexion contracture remains after manipulation, revision TKA, which may be considered as a useful treatment option, should be considered.
Acetabular reconstruction of a total hip arthroplasty (THA) for a case with severe bone loss is most challenging for surgeon. Relatively high rate of failure after the reconstruction surgery have been reported. We have used Kerboull-type acetabular reinforcement devices with morsellised or bulk bone allografts for these cases. The purpose of this study was to examine the midterm results of revision THA using Kerboull-type acetabular reinforcement devices. We retrospectively reviewed 20 hips of revision THA (20 patients) between February 2002 and August 2010. The mean age of the patients at the time of surgery was 67.4 years (range 45–78). All of the cases were female. The mean duration of follow-up was 6.5 years (range 2.1–10.4). The reasons of revision surgeries were aseptic loosening in 10 hips, migration of bipolar hemiarthroplasty in 8 hips, and rheumatoid arthritis in 2 hips. We classified acetabular bone defects according to the American Academy of Orthopaedic Surgeons (AAOS) classification; we found two cases of Type II and eighteen cases of Type III. In terms of bone graft, we performed both bulk and morsellised bone grafts in 6 hips and morsellised bone grafts only in 14 hips. We assessed cup alignment using postoperative computed tomography (CT) and The post-operative and final follow-up radiographs were compared to assess migration of the implant. We measured the following three parameters: the angle of inclination of the acetabular device (Fig. 1); the horizontal migration (Fig. 2a); and vertical migration (Fig. 2b). Substantial migration was defined as a change in the angle of inclination of more than 3 degrees or migration of more than 3 mm. The pre- and postoperative hip functions were evaluated using the Japanese Orthopaedic Association (JOA) hip score.Introduction
Patients and methods
Ankle arthrodesis is a common treatment for destroyed ankle arthrosis with sacrificing the range of motion. On the other hand, total ankle arthroplasty (TAA) is an operation that should develop as a method keeping or improving range of motion (ROM); however, loosening and sinking of the implant have been reported in especially constrained designs of the implant. The concept of FINE TAA is the mobile bearing system (Nakashima Medical Co., Ltd, Okayama Japan) that can reduce stress concentration to implants. The purpose of this study is to evaluate the short-term results of FINE TAA. We performed FINE TAA for osteoarthritis (OA) (2 ankles of 2 patients) and rheumatoid arthritis (RA) (4 ankles of 3 patients). All patients were female. The mean age of the patients was 71.4 years old at the operation. The mean follow-up period was 32.6 (range, 18–55) months. All patients were assessed for Japan Orthopedic Association (JOA) score and ROM in plantar flexion and dorsiflexion at the point of pre-operation and final follow-up. We evaluated radiolucent line, subsidence, and alignment of implants at the latest follow-up.Introduction
Objectives and Methods
While research has been carried out widely for sagital pelvic tilt, research reports for coronal pelvic obliquity are few. The aim of this study is to evaluate changes of the pelvic obliquity before and after total hip arthroplasty. This retrospective study includes 146 cases of hips that were received total hip arthroplasty. There were 20 cases of revision, and 2 cases of re-revision. 17 cases were received bilateral total hip arthroplasty. The standing plain X-ray was used for evaluation of the pelvic obliquity in both before and 1-year after surgery. The correlation of pelvic obliquity was assessed between before and after surgery. 146 cases were classified into 3 groups (A, B, and C) according to the severity of the pelvic obliquity (0º−3º, 3º−6º, and >6º). Among the groups, statistical analysis was evaluated in the leg length discrepancy and the range of motion of the hip (flexion, extension, abduction, adduction, internal and external rotation) before and after surgery with 95% confidence intervals.Introduction
Material and Methods
Pelvic osteotomy such as Chiari osteotomy and rotational acetabular osteotomy (RAO) have been used successfully in patients with developmental dysplasia of the hip (DDH). However, some patients are forced to undergo total hip arthroplasty (THA) because of the progression of osteoarthritis. THA after pelvic osteotomy is thought to be more difficult because of altered anatomy of the pelvis. We compared six THAs done in dysplastic hips after previous pelvic osteotomy between 2008 and 2015 with a well-matched control group of 20 primary procedures done during the same period. Six THAs for DDH after previous Pelvic osteotomy (three Chiari osteotomies and three RAOs) were compared with 20 THAs for DDH without previous surgery. The patients were matched for age, sex, and BMI. Minimum follow-up for both groups of patients was one year (range, 12–79 months and 12–77 months, respectively). The average interval from pelvic osteotomy to total hip arthroplasty was 19.8 years (range 12–26 years). Clinical and Radiological evaluations were performed.Introduction
Materials and methods
Proximal femoral osteotomy is an attractive joint preservation procedure for osteonecrosis of the femoral head. The purpose of this study was to investigate the cause of failure of proximal femoral osteotomy in patients with osteonecrosis of the femoral head. Between 2008 and 2014, proximal femoral osteotomy was performed by one surgeon in 13 symptomatic hips. Ten trans-trochanteric rotational osteotomies (anterior: 7, posterior: 3) and 3 intertrochanteric curved varus osteotomy were performed. Of the patients, 9 were male and 1 was female, with a mean age at surgery of 36.9 years (range, 25–55 years). The mean postoperative follow-up period was 38 months (range, 12–72 months). Three patients (4 hips) had steroid-induced osteonecrosis, and 7 (9 hips) had alcohol-associated osteonecrosis. At 6 postoperative weeks, partial weight bearing was permitted with the assistance of 2 crutches. At more than 6 postoperative months, full weight bearing was permitted. Patients who had the potential to achieve acetabular coverage of more than one-third of the intact articular surface on preoperative hip radiography, computed tomography, and magnetic resonance imaging were considered suitable for this operation. A clinical evaluation using the Japanese Orthopaedic Association (JOA) scoring system and a radiologic evaluation were performed. Clinical failure was defined as conversion to total hip arthroplasty (THA) or progression to head collapse and osteoarthritis. The 13 hips were divided into two groups, namely the failure and success groups.Purpose
Patients and Methods
Continuous epidural anesthesia or femoral nerve block has decreased postoperative pain after total knee arthroplasty to some extent. Although the established efficacy of these pain relief method, some adverse events such as hematoma or muscle weakness are still problematic. Intraoperative local infiltration of analgesia (LIA) has accepted as a promising pain control method after total knee arthroplasty. The safety and efficacy of LIA has been reported, although there are still limited evidence about the effect of LIA on quadriceps function and recovery of range of motion in early post-operative phase. The purpose of this study is to compare the quadriceps function and range of motion after TKA between the LIA with continuous epidural anesthesia and continuous epidural anesthesia alone. Thirty patients with knee osteoarthritis who underwent primary TKA were included in this study. Patients who took anticoagulants were treated continuous epidural anesthesia alone (n=11) and the other patients were treated with LIA with continuous epidural anesthesia (n=19). A single surgeon at our department performed all surgeries. Surgical procedure and rehabilitation process was identical between two groups. Before the implantation, analgesic drugs consisting of 20 ml of 0.75 % ropivacaine and 6.6 mg of dexamethasone were injected into the peri-articular tissues. In each group, fentanyl continuous epidural patient-controlled analgesia (PCA) was also used during 48-h post-operative period. Knee flexion and extension angle were evaluated before surgery, post-op day 3, 7, 10 and 14. The quadriceps function was evaluated by quadriceps peak torque at 30° and 60° flexion using VIODEX. The peak torque was recorded preoperatively, day 14 and 3 month after surgery. The difference between two groups was analyzed by Mann Whitney U-test using Prism 6, a statistical software.Background
Methods
Rotational malalignment of the femoral component still causes patellofemoral complications that result in failures in total knee arthroplasty (TKA). To achieve correct rotational alignment, a couple of anatomical landmarks have been proposed. Theoretically, transepicondylar axis has been demonstrated as a reliable rotational reference line, however, intraoperative identification of the transepicondylar axis is challenging in some cases. Therefore, surgeons usually estimate the transepicondylar axis from posterior condylar axis (PCA) using twist angle determined by the preoperative X-rays and CT. While PCA is the most apparent landmark, radiographs are not able to detect posterior condylar cartilage. In most osteoarthritic knees, the cartilage thickness of the posterior condyle is different between medial and lateral condyles. The purpose of this study is to evaluate the effect of the posterior condylar cartilage on rotational alignment of the femoral component in large number of arthritic patients. Furthermore, we investigated whether the effect of posterior condylar cartilage is different between osteoarthritis (OA) and rheumatoid arthritis (RA). Ninety-nine OA knees and 36 RA knees were included. Detailed information is summarized in Table 1. All cases underwent TKA using navigation system. The institutional review board approved the study protocol and informed consent was obtained from each participants. To evaluate the effect of posterior condylar cartilage, we measured two different condylar twist angle (CTA) using navigation system and intraoperative fluoroscopy-based multi-planner reconstruction (MPR) images obtained by a mobile C-arm. To uniform the SEA in two different measuring systems, we temporary inserted a suture anchors in medial and lateral prominence. The CTA that does not include the posterior condylar cartilage (MPR CTA) is evaluated on MPR images and the CTA that does include the posterior condylar cartilage (Navi. CTA) is calculated by navigation system. The difference between these two angles corresponds to the effect of posterior condylar cartilage on the rotation of the femoral component (Fig. 1). The paired or unpaired t test was used to compare the obtained data. The statistics were performed using GraphPad Prism 6. A P value of 0.05 or less is considered as a significant difference.Objective
Methods
Recently, there are increasing literatures of the in vivo kinematics of total knee arthroplasty (TKA). Those previous studies have been reported in regard of either intra-operative kinematics or post-operative kinematics. However, the direct correlation between intra- and post-operative kinematics of TKA has not been revealed. There are no evidences that intra-operative kinematics can lead to post-operative kinematics. The purpose of this study is to verify the direct correlation between intra- and post-operative kinematics of TKA.Introduction
Purpose
The aim of this study is to verify the intra-rater and inter-rater reliability of intra-operative kinematics by hand in TKA using a computer assisted image-free navigation system. Total knee arthroplasty (TKA) was performed on the knees of twelve (12) patients with knee navigation by one surgeon. Patients were divided into two groups: Group A included six knees that were operated on with assistant A (senior joint surgeon); and Group B included the other six knees that were operated on with assistant B (resident). For each knee, axial rotation was evaluated three times by the operator and the assistant using a navigation system at 30°, 60°, 90°, 120° passive flexions by hand. Intra-class correlation coefficients (ICC) were calculated for each evaluation to examine intra-rater and inter-rater reliability.Introduction
Material and Methods