Cells typically respond to a variety of geometrical cues in their environment, ranging from nanoscale surface topography to mesoscale surface curvature. The ability to control cellular organisation and fate by engineering the shape of the extracellular milieu offers exciting opportunities within tissue engineering. Despite great progress, however, many questions regarding geometry-driven tissue growth remain unanswered. Here, we combine mathematical surface design, high-resolution microfabrication, in vitro cell culture, and image-based characterization to study spatiotemporal cell patterning and bone tissue formation in geometrically complex environments. Using concepts from differential geometry, we rationally designed a library of complex mesostructured substrates (101-103 µm). These substrates were accurately fabricated using a combination of two-photon polymerisation and replica moulding, followed by surface functionalisation. Subsequently, different cell types (preosteoblasts, fibroblasts, mesenchymal stromal cells) were cultured on the substrates for varying times and under varying osteogenic conditions. Using imaging-based methods, such as fluorescent confocal microscopy and second harmonic generation imaging, as well as quantitative image processing, we were able to study early-stage spatiotemporal cell patterning and late-stage extracellular matrix organisation. Our results demonstrate clear geometry-dependent cell patterning, with cells generally avoiding convex regions in favour of concave domains. Moreover, the formation of multicellular bridges and collective curvature-dependent cell orientation could be observed. At longer time points, we found clear and robust geometry-driven orientation of the collagenous extracellular matrix, which became apparent with second harmonic generation imaging after ∼2 weeks of culture. Our results highlight a key role for geometry as a cue to guide spatiotemporal cell and tissue organisation, which is relevant for scaffold design in tissue engineering applications. Our ongoing work aims at understanding the underlying principles of geometry-driven tissue growth, with a focus on the interactions between substrate geometry and mechanical forces.
Thoracic hyperkyphosis (TH – Cobb angle >40°) is correlated with rotator cuff arthropathy and associated with anterior tilting and protraction of scapula, impacting the glenoid orientation and the surrounding musculature. Reverse total shoulder arthroplasty (RTSA) is a reliable surgical treatment for patients with rotator cuff arthropathy and recent literature suggests that patients with TH may have comparable range of motion after RTSA. However, there exists no study reporting the possible link between patient-reported outcomes, humeral retroversion and TH after RTSA. While the risk of post-operative complications such as instability, hardware loosening, scapular notching, and prosthetic infection are low, we hypothesize that it is critical to optimize the biomechanical parameters through proper implant positioning and understanding patient-specific scapular and thoracic anatomy to improve surgical outcomes in this subset of patients with TH. Patients treated with primary RTSA at an academic hospital in 2018 were reviewed for a two-year follow-up. Exclusion criteria were as follows: no pre-existing chest radiographs for Cobb angle measurement, change in post-operative functional status as a result of trauma or medical comorbidities, and missing component placement and parameter information in the operative note. As most patients did not have a pre-operative chest radiograph, only seven patients with a Cobb angle equal to or greater than 40° were eligible. Chart reviews were completed to determine indications for RTSA, hardware positioning parameters such as inferior tilting, humeral stem retroversion, glenosphere size/location, and baseplate size. Clinical data following surgery included review of radiographs and complications. Follow-up in all patients were to a period of two years. The American Shoulder and Elbow Surgeons (ASES) Shoulder Score was used for patient-reported functional and pain outcomes. The average age of the patients at the time of RTSA was 71 years old, with six female patients and one male patient. The indication for RTSA was primarily rotator cuff arthropathy. Possible correlation between Cobb angle and humeral retroversion was noted, whereby, Cobb angle greater than 40° matched with humeral retroversion greater than 30°, and resulted in significantly higher ASES scores. Two patients with mean Cobb angle of 50° and mean humeral retroversion 37.5° had mean ASES scores of 92.5. Five patients who received mean humeral retroversion of 30° had mean lower ASES scores of 63.7 (p < 0 .05). There was no significant correlation with glenosphere size or position, baseplate size, degree of inferior tilting or lateralization. Patient-reported outcomes have not been reported in RTSA patients with TH. In this case series, we observed that humeral stem retroversion greater than 30° may be correlated with less post-operative pain and greater patient satisfaction in patients with TH. Further clinical studies are needed to understanding the biomechanical relationship between RTSA, humeral retroversion and TH to optimize patient outcomes.
The purpose of this study was to compare the clinical outcomes, mortalities, implant survival rates, and complications of total knee arthroplasty (TKA) in patients with or without hepatitis B virus (HBV) infection over at least ten years of follow-up. From January 2008 to December 2010, 266 TKAs were performed in 169 patients with HBV (HBV group). A total of 169 propensity score–matched patients without HBV were chosen for the control group in a one-to-one ratio. Then, the clinical outcomes, mortalities, implant survival rates, and complications of TKA in the two groups were compared. The mean follow-up periods were 11.7 years (10.5 to 13.4) in the HBV group and 11.8 years (11.5 to 12.4) in the control group.Aims
Methods
In this study, we aimed to explore surgical variations in the Femoral Neck System (FNS) used for stable fixation of Pauwels type III femoral neck fractures. Finite element models were established with surgical variations in the distance between the implant tip and subchondral bone, the gap between the plate and lateral femoral cortex, and inferior implant positioning. The models were subjected to physiological load.Aims
Methods
This paper aims to analyze the kinetics of the over-ground wheel-type body weight supporting system (BWS); tendency changes of low extremity joint moment (hip, knee, ankle), 3 axis accelerations of a trunk, cadence and gait velocity as weight bearing level changes. 15 subjects (11 males, 4 females, age:23.63.5, height:170.65.1cm, weight:69.0210.75kg) who had no history of surgery participated. 6 levels (0%, 10%, 20%, 30%, 40% and 50%) of BWS were given to subjects at self-selected gait velocity and kinetic data was calculated using a motion capture system, Vicon® (Vicon, UK).Objective
Method
Management and outcomes of fungal periprosthetic joint infection (PJI) remain unclear due to its rarity. Although two-stage exchange arthroplasty is considered a treatment of choice for its chronic features, there is no consensus for local use of antifungal agent at the 1st stage surgery. The purpose of this study was to evaluate the efficacy of antifungal-impregnated cement spacer in two-stage exchange arthroplasty against chronic fungal PJIs after total knee arthroplasty (TKA). Nine patients who were diagnosed and treated for chronic fungal PJIs after TKA in a single center from January 2001 to December 2016 were enrolled. Two-stage exchange arthroplasty was performed. During the 1st stage resection arthroplasty, amphotericin-impregnated cement spacer was inserted for all patients. Systemic antifungal medication was used during the interval between two stage operations. Patients were followed up for more than 2 years after exchange arthroplasty and their medical records were reviewed.Purpose
Methods
Suture anchor have been used in surgical procedure of tendon or ligament repair. Recently, there has been developed an all suture anchor (soft anchor) which can be used even when the insertion area is narrow. But, the stability of soft anchors due to narrow zone has not been elucidated. This purpose of this study was to investigate stability of soft anchors with respect to their fixation intervals. Polyurethane foams with two different bone densities (10 pcf; 0.16g / cm³, 20 pcf; 0.32g / cm) were used. All suture anchors and conventional suture anchors were fixed at 10mm, 5mm, and 2.5mm intervals. The failure load was measured using a mechanical testing machine.Introduction
Methods
The current study aimed to determine the influence of acetabular coverage and intraarticular pathology on post-operative functional outcomes of arthroscopy for cam type FAI. Based on 762 hip scopes performed by a single surgeon between 2013 and 2016, we excluded patients with previous surgery on the hip, mixed FAI, surgical hip dislocation, and missing outcome scores. From this, 97 hips between the ages 17 and 48 that underwent arthroscopy for cam deformity were identified for analysis. Every patient received a partial capsulotomy, cam resection and either labral repair or resection. Measurements for acetabular coverage consisted of pre-operative lateral edge angle (LCEA) (mean 30°, range: 15.4°–40°) and three-dimensional anterior and posterior acetabular coverages. Intraoperative Beck scores were acquired from operative reports, and Hip Disability and Osteoarthritis Outcome Score (HOOS) was collected pre- and post-operatively. Significant post-operative improvement was found in scores of all categories of the HOOS (p < 0.05). However, improvement in HOOS was not correlated with the LCEA, anterior coverage, or posterior coverage. There was a trend toward lower Beck grades (1–3) resulting in better HOOS outcomes than higher Beck grades (4–5). Also, lower Beck grades showed significantly lower alpha angle (mean = 55.86) than higher grades (mean = 73.48). We showed that cam FAI arthroscopic resection improved patient outcome, and confirmed the relationship between the Beck score and functional outcome. However, functional improvement was not related to acetabular coverage suggesting that the so-called “borderline” dysplasia is not a useful radiographic indicator for surgical management.
The objective of this study was to assess the association between whole body sagittal balance and risk of falls in elderly patients who have sought treatment for back pain. Balanced spinal sagittal alignment is known to be important for the prevention of falls. However, spinal sagittal imbalance can be markedly compensated by the lower extremities, and whole body sagittal balance including the lower extremities should be assessed to evaluate actual imbalances related to falls. Patients over 70 years old who visited an outpatient clinic for back pain treatment and underwent a standing whole-body radiograph were enrolled. Falls were prospectively assessed for 12 months using a monthly fall diary, and patients were divided into fallers and non-fallers according to the history of falls. Radiological parameters from whole-body radiographs and clinical data were compared between the two groups.Objectives
Methods
Clinical and radiological results of total hip arthroplasty (THA) using proximally coated single wedge (PSW) cementless stems are generally excellent. The geometry of cementless stems and the morphology of proximal femurs (Dorr types) provide optimal fit for primary stability and secondary biologic fixation. Because the geometry of PSW shape is designed to be engaged at the metaphysis, cementless PSW stem is not traditionally recommended to Dorr type C femurs with concerns of inadequate implant-host bone contact and the risk of femoral fracture. Nevertheless, previous studies on PSW cementless stems have not examined long-term survivorship according to Dorr types of femur. Paucity of a long-term comparative study makes it difficult to know whether the PSW stem plays a role in Dorr type C femurs or not. We postulated that the PSW stem could achieve stable fixation without increased risk of femoral fracture even in Dorr type C femurs, and demonstrate acceptable long-term results. The aim of this study was to investigate differences of clinical and radiological outcomes of THA using PSW stem according to proximal femoral geometry (Dorr types) in more than a 10-year follow-up. Three hundred and seven primary THA in 247 patients, which was performed with use of a single-designed PSW stem from 1997 to 2003 and was followed up for over 10 years, were included in this retrospective study. According to Dorr's criteria, 89 femora were classified as Type A, 156 as Type B, and 62 as Type C. The patients' mean age at operation was 43.2 years (range, 18.4 – 69.6 years). They were followed-up for an average of 13.2 years (the range, 10.0 – 17.3 years). All of the hips were evaluated clinically and radiologically with special attention to the occurrence of implant loosening and periprosthetic femoral fracture. The mean preoperative Harris hip score (50.4±20.6 points) improved significantly to 95.6±9.0 points at the final follow-ups. The improvements were observed regardless of Dorr types (p<0.001 in all 3 groups). The incidence of thigh pain (p=0.704) was not significantly different among groups. Implant survivorship was 100% in all 3 groups. None of the stems were loosened or revised. No significant differences were observed in osteolysis (p=0.492), pedestal formation (p=0.323), or cortical hypertrophy (p=0.169) among the groups [Fig. 1]. Radiolucent lines less than 2mm in thickness in Gruen zone 4 were observed more in Dorr type C femora than in Dorr type A or B (p=0.003) [Fig. 2]. Spot weld (p<0.001) and stress shielding (p=0.010) of proximal femur were more pronounced in Dorr C type femora than in type A or B [Fig. 3]. The prevalence of intraoperative (p=0.550) or postoperative (p=0.600) femoral fractures were not significantly different among the groups. From over a 10-year follow-up, the PSW stem provided excellent stem survivorship regardless of Dorr type with satisfactory outcomes. The remodeling process around the stem was more pronounced in Dorr type C femur. The present study shows that the PSW stem is a recommendable option for Dorr type C femur.
Alternative bearing surfaces has been introduced to reduce wear debris-induced osteolysis after total hip arthroplasty (THA) and offered favorable results. Large population-based data for total joint surgery permit timely recognition of adverse results and prediction of events in the future. The purpose of this study was to present the epidemiology and national trends of bearing surface usage in primary total hip arthroplasty (THA) in Korea using nationwide database. A total of 30,881 THAs were analyzed using the Korean Health Insurance Review and Assessment Service database for 2007 through 2011. Bearing surfaces were sub-grouped according to device code for national health insurance claims and consisted of ceramic-on-ceramic (CoC), metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), and metal-on-metal (MoM). The prevalence of each type of bearing surface was calculated and stratified by age, gender, hospital type, primary payer, and procedure volume of each hospital. The number of primary THAs increased by 25.2% from 5,484 in 2007 to 6,866 in 2011. The average age of the entire study population was 58.1 years, and 53.5% were male [Table 1]. CoC was the most commonly used bearing surface (76.7%), followed by MoP (11.9%), CoP (7.3%), and MoM (4.1%). The distribution of bearing surfaces was identical to that in the general population regardless of age, gender, hospital type, and primary payer [Table 2]. The mean age of patients that received hard-on-hard bearing surfaces (CoC and MoM) was significantly younger than that of patients receiving hard-on-soft bearing surfaces (CoP and MoP) (56.9 years vs. 62.6 years). During the study period, 55.1% of THAs that used a hard-on-hard bearing surface were performed in males, while 53.0% of THAs that used a hard-on-soft bearing surface were performed in females. The order of prevalence of bearing surfaces was identical in low- and medium-volume hospitals (CoC was first, MoP was second, CoP was third, and MoM was fourth). The mean hospital charges did not differ according to the bearing surface used, with the exception of CoP, which was associated with a lower mean hospital charge. There were no changes in the distribution of bearing surfaces in each year between 2007 and 2011. Overall, the percentage of THAs that used CoC bearing surfaces increased substantially from 71.6% in 2007 to 81.4% in 2011, while the percentage that used CoP, MoP, and MoM decreased significantly [Fig. 1]. One of the reasons for the dominant usage of hard-on-hard bearing surfaces may be that the principal diagnosis of primary THAs and the patient age group distribution in Korea differ from those in other countries. The most common indication for primary THA is osteonecrosis of the femoral head in Korea. In contrast, the majority of primary THAs are performed for osteoarthritis in Western countries. The choice of bearing surface may be affected by many factors, including the nation's medical delivery system, payment type, disease pattern, and age distribution of patients that undergo THA. In future, the results of a large-scale nationwide study on primary THAs using CoC bearing surfaces in Korea will be reported.
Proper positioning of the baseplate and optimal screw placement are necessary to avoid loosening or failure of the glenoid component in RTSA. Several in vitro and anatomic studies have documented ideal number, size, length and angulation of baseplate screws. However, such fixation can often be tenuous, as the anatomy of scapula bone varies. Furthermore, it can be difficult to identify regions with the best bone stock intraoperatively even though surgeons have an understanding of scapular anatomy with potential screw trajectories in mind. This often leads to variable screw lengths and angulations in the clinical setting. The purpose of this study was to measure optimal screw lengths and angles to reach ideal regions in cadaveric scapulae and to compare the clinical experiences of three surgeons with each other and against a cadaveric model with screw lengths and angulations. Seven cadaveric scapulae were used as the template for optimal screw angulation and length for baseplate implantation. Total 21 cases (seven cases of each 3 surgeons) of reverse total shoulder arthroplasty using the Aequalis®-Reversed shoulder prosthesis (Tornier, France) were included. Measurement of screw angulation was done on the AP and axillary views to account for the superior-inferior and the antero-posterior angulations, respectively. The screw lengths used on each scapula was recorded prior to insertion in cadavers and retrieved from the operative records in clinical cases. Screws directed anteriorly and superiorly were recorded as positive values while posteriorly and inferiorly directed screws were designated negative values. The significant differences in degrees of screw angulation and screw lengths among the 3 surgeon groups were calculated using the ANOVA, with the p value at 0.05. The Mann-Whitney U test was performed to evaluate the cadaver group against the surgeon groups.Introduction
Materials and Methods
A cell-based tissue-engineered construct can be employed for treating meniscal lesions occurring in the non-vascularized inner two-thirds. The objective of this study was to test the hypothesis that both pre-differentiation of human bone marrow derived stromal cells (hBMSCs) into chondrogenic lineage before cell seeding and platelet-rich plasma (PRP) pretreatment on a PLGA mesh scaffold enhances the healing capacity of the meniscus with hBMSCs-seeded scaffolds PRP of 5 donors was mixed and used for the experiments. The woven PLGA mesh scaffold (VicrylTM, Ethicon) measuring 20×8 mm (thickness, 0.2 mm) was prepared. The scaffolds were immersed into 1,000 μl of PRP and were centrifuged at 150g for 10 min. Then, the scaffold was flipped 180° and the same procedure was done for the other side. After washing, the scaffolds were soaked into 1,000 μl of DMEM media. hBMSCs from an iliac crest of 10 patients after informed consent and approval of our IRB were induced into chondrogenic differentiation with chondrogenic media containing 10 ng/ml rhTGF-ß3 in 1.2% alginate bead culture system for 7 days. Then, 2×105 hBMSCs were recovered, seeded onto the scaffold, and cultured under dynamic condition. Based on the presence of pre-differentiation into chondrogenic lineage and the PRP pretreatment, 4 study groups were prepared. (no differentiation without PRP, no differentiation with PRP, chondrogenic differentiation without PRP, chondrogenic differentiation with PRP) Cell number for each cell-seeded scaffold was determined at 24 hours after seeding. Then, scaffolds were placed between human meniscal discs and were implanted subcutaneously in nude mice for 6 weeks (n=10 per group).Background
Methods
Total knee arthroplasty (TKA) is a well proven surgical procedure. Squat and gait motions are common activities in daily life. However, squat motion is known as most dissatisfying motion in activities in daily life after total knee arthroplasty (TKA). Dissatisfaction after TKA might refer to muscle co-contraction between quadriceps and hamstrings. The purposed of this study was to develop squat and gait simulation model and analyses the contact mechanics and quadriceps and hamstring muscle stability. We hypothesized that squat model shows larger contact forces and lower hamstring to quadriceps force ratio than gait model. Squat motion and gait model were simulated in musculoskeletal simulation software (AnyBody Modeling System, AnyBody Technology, Denmark). Subject-specific bone models used in the simulation were reconstructed from CT images by Mimics (Materialize, Belgium). The lower extremity model was constructed with pelvis, femur, tibia, foot segments and total knee replacement components: femoral component, tibial insert, tibial tray, and patella component [Fig.1]. The muscle model was consisted of 160 muscle elements. The TKR components used in this study are PS-type LOSPA Primary Knee System (Corentec Co., Ltd, Republic of Korea). Force-dependent kinematics method was used in the simulation. The model was simulated to squat from 15° to 100° knee flexion, in 100 frames. Gait simulation model was based on motion capture and force-plate system. Motion capture and force-plate data were from grand challenge competition dataset.Introduction
Materials and Methods
The mid- or long-term results of acetabular revision total hip arthroplasty (THA) in Korea are rare. The purpose of this study is to report the mid-term radiographic results (> 5 years) of acetabular revision THA with porous-coated cementless Trilogy® cup (Zimmer, Warsaw, IN, USA). Between 1999 and 2010, 77 patients (79 hips) had underwent acetabular revision THA with Trilogy® cup. Eight patients (8 hips) were excluded due to death before 5-year follow-up, and 22 patients (23 hips) were excluded due to less than 5-year follow-up or follow-up loss. Forty-seven patients (48 hips) were included in our study. The mean age was 57.9 years (range, 36 to 76 years) and the mean follow-up was 9.8 years (range 5.0 to 16.2 years). The causes of revision were aseptic loosening in 40 hips, and septic loosening in 8 hips, respectively. Both acetabular and femoral revisions were performed in 14 hips and isolated acetabular revision was done in 34 hips. Preoperetive acetabular bone defect according to Paprosky classification was; 1 in type I, 6 in IIA, 11 in IIB, 9 in IIC, 15 in IIIA, and 6 in IIIB.Introduction
Materials and Methods
To compare the clinical and radiological results between internal fixation using the proximal femoral nail system and bipolar hemiarthroplasty in reverse oblique intertrochanteric hip fracture in elderly patients. From January 2005 to July 2012, we reviewed 53 patients who had been treated surgically for reverse oblique intertrochanteric fracture and been followed up on for a minimum of 2 years. The patients, all over 70 years old, were divided into two groups for retrospective evaluation: one group was treated with open reduction and internal fixation using the proximal femoral nail system (31 cases), and the other group was treated with bipolar hemiarthroplasty (22 cases).Purpose
Materials and Methods
Mechanically assisted crevice corrosion (MACC) of head-neck modular taper junctions is prevalent in virtually all head neck tapers in use today. To date, no clear in vitro tests of design, material or surgical elements of the modular taper system have been reported that show which factors principally affect MACC in these tapers. Possible elements include seating load, head-neck offset, surface roughness, taper engagement length, material combination, angular mismatch, and taper diameter. The goals of this study were to use an incremental fretting corrosion test method1 to assess the above 7 elements using a design of experiments approach. The hypothesis is that only one or two principal factors affect fretting corrosion. A 27-2 design of experiment test (7 factors, ¼ factorial, n=32 total runs, 16 samples per condition per factor) was conducted. Factors included: Assembly Force (100, 4000N), Head Offset (1.5, 12 mm), Taper Locking Position (Mouth, Throat), Stem Taper Length (0.44, 0.54 in), Stem Taper Roughness (Ground, Ridged), Taper Diameter (9/10, 12/14), and Stem Material (CoCrMo, Ti-6Al-4V). The heads were CoCrMo coupled with taper coupons (DePuy Synthes, Warsaw, IN). Test components were assembled wet and seated axially with 100 or 4000N assembly force. The assemblies were immersed in PBS and potentiostatically held at −50mV vs. Ag/AgCl. Incremental cyclic loads were applied vertically to the head at 3Hz until a 4000N maximum load was reached (See Fig. 1). Fretting currents at 4000 N cyclic load were used for comparisons while other parameters, including onset load, subsidence, micromotion and pull off load were also captured. Statistical analysis was performed using Pareto charts and Student's T-tests for single factor comparisons (P < 0.05 was statistically significant).Introduction
Methods
We evaluated the clinical and radiographic outcomes of cementless bipolar hemiarthroplasty using rectangular cross-section stem for femoral neck fracture in elderly patients more than 80 years of age with osteoporosis. 76(cemented 46, cementless 30) bipolar hemiarthroplasties for femur neck fracture were performed in elderly patients more than 80 years old. The mean follow-up period was 4.3 years (2 to 7 years). The Harris hip score at last follow-up and pre-postoperative daily living activity scale according to Kitamura methods were analyzed clinically. The radiological results were assessed using stability of femoral stem and other complications were evaluated. Results: At last follow-up, there were no significant differences of Harris hip score and daily living activity between two groups. Stem loosening and instability were not observed in cementless arthroplasty. There were 18 cases of osseous fixation in radiologic study. There were 1 case of dislocation and 1 case of superficial infection in cemented arthroplasty and 1 case of deep infection in cementless arthroplasty.Purpose
Material and Methods
Rotational alignment is important for the long-term success and good functional outcome of total knee arthroplasty (TKA). While the surgical transepicondylar axis (sTEA) is the generally accepted landmark on the distal femur, a precise and easily identifiable anatomical landmark on the tibia has yet to be established. Our aim was to compare five axes on the proximal tibia in normal and osteoarthritic (OA) knees to determine the best landmark for determining rotational alignment during TKA. One hundred twenty patients with OA knees and 30 without knee OA were recruited for the study. Computed tomography (CT) images were obtained and converted through multiplanar reconstruction so the angles between the sTEA and the axes of the proximal tibia could be measured. Five AP axes were chosen: the line connecting the center of the posterior cruciate ligament(PCL) and the medial border of the patellar tendon at the cutting level of the tibia (PCL-PT), the line from the PCL to the medial border of the tibial tuberosity (PCL-TT1), the line from the PCL to the border of the medial third of the tibia (PCL-TT2), the line from the PCL to the apex of the tibia (PCL-TT3), and the AP axis of the tibial prosthesis along with the anterior cortex of the proximal tibia (anterior tibial curved cortex, ATCC).Background
Methods
Although vertebroplasty is very effective for relieving acute pain from an osteoporotic vertebral compression fracture, not all patients who undergo vertebroplasty receive the same degree of benefit from the procedure. In order to identify the ideal candidate for vertebroplasty, pre-operative prognostic demographic or clinico-radiological factors need to be identified. The objective of this study was to identify the pre-operative prognostic factors related to the effect of vertebroplasty on acute pain control using a cohort of surgically and non-surgically managed patients. Patients with single-level acute osteoporotic vertebral compression fracture at thoracolumbar junction (T10 to L2) were followed. If the patients were not satisfied with acute pain reduction after a three-week conservative treatment, vertebroplasty was recommended. Pain assessment was carried out at the time of diagnosis, as well as three, four, six, and 12 weeks after the diagnosis. The effect of vertebroplasty, compared with conservative treatment, on back pain (visual analogue score, VAS) was analysed with the use of analysis-of-covariance models that adjusted for pre-operative VAS scores.Objectives
Patients and Methods