We assessed the clinical and radiological outcome of a single uncemented total hip replacement (THR) after twenty years, analysing polyethylene wear and osteolysis. 82 hips implanted between 1992 and 1995 were prospectively evaluated. Mean follow-up was 20.6 years (18–23). A hemispherical porous-coated cup matched to a proximally hydroxyapatite-coated anatomic stem. A 28mm PE liner, sterilised by gamma irradiation in air, was used in all hips. Radiological position, eventual loosening and osteolysis were recorded over time. Penetration of the head into the liner was measured by the Roentgen Monographic Analysis (ROMAN) Tool at 6 weeks, 6 months, one year and yearly thereafter. Six cups were revised due to wear and four cups because of late dislocation. All stems showed osseointegration and all cups appeared radiographically well-fixed. Six unrevised hips showed osteolysis on the acetabular side and two hips on the proximal femur. Creep at one year was 0.30±0.23 mm. Mean total femoral head penetration was 1.23mm at ten years, 1.52mm at 15 years and 1.92mm at 23 years. Overall mean wear was 0.12±0.1 mm/year and 0.09±0.06 mm/year after the creep period. Mean wear was 0.08±0.06 mm/year in hips without osteolysis and 0.14±0.03 mm/year in hips revised or hips with osteolysis (p<0.001). Although continued durable fixation can be observed with porous-coated cups and proximally hydroxyapatite-coated anatomic stems, true wear continues to increase at a constant level over time. PE wear remains as the main reason for osteolysis and revision surgery in uncemented THR after twenty years.
Although the tribological characteristics are excellent, cup fixation has been one of the limitations in alumina-on-alumina total hip replacement (THR), so different types of materials and surfaces have been developing. We analysed the clinical and radiological outcome of two different uncemented cups for the same alumina-on-alumina THR. 679 hips were prospectively followed for at least 5 years. 342 had a hydroxyapatite (HA)-coated relatively smoothed tri-radius cup, implanted between 1999 and 2005 (group 1), and, 337 had a HA-coated macotextured tri-radius implanted between 2006 and 2009 (group 2). Dysplastic hips were more frequently observed in group 2. We compared screw use in both groups as primary fixation, the clinical results, and the radiological appearance of cup loosening.Background
Methods
Recent proposals have been introduced to modify stem design and/or femoral fixation in total hip replacement (THR). New designs need to consider previous design features and their results. The aim of this study has been to evaluate the clinical and radiological results of six different designs of tapered uncemented stems implanted in our Institution. 1918 uncemented hips were prospectively assessed from 1999 to 2011 (minimum follow-up of five years for the unrevised hips). All hips had a 28 or 32 mm femoral head and metal-on-polyethylene or alumina-on-alumina bearing surface. Six uncemented femoral designs that shared a femoral tapered stem incorporating a coating surface were included in the study. The different design features included the type of coating, metaphyseal filling, and sectional shape.Background and aim
Methods
Total hip replacement (THR) in young patients has been associated to higher revision rates than in older population. Different conditions may lead to end-stage arthritis of the hip in these patients. We compared the clinical and radiological outcome of two different groups of young and very young patients who underwent a ceramic-on-ceramic THR. 120 hips were prospectively followed for a mean of 10.4 years (range, 5 to 17). 38 patients (46 hips) were less than 30 years old (group 1), and, 68 (74 hips) were between 31 and 40 years old (group 2). Weight (p<0.001) and physical activity level were greater in group 2 (p<0.001). Preoperative function (p=0.03) and range of mobility (p=0.03) were worse in group 1. Primary osteoarthritis was not found in any case. Rheumatoid juvenile arthritis was the most frequent diagnosis in group 1 and avascular necrosis of the femoral head in group 2. A femoral funnel-shaped type 1 according to Dorr was more frequent in group 2 (p=0.04). The same ceramic-on-ceramic uncemented THR was used in all cases. Screws for cup fixation were only used when strictly needed. We analysed the clinical results according to the Merle-D´Aubignè and Postel scale, the postoperative radiological reconstruction of the hip and the radiological appearance of cup loosening. Kaplan-Meier survivorship analysis was used to estimate the cumulative probability of not having a revision surgery. Screw use required to obtain a secured interference fit of the acetabular component was found more frequently in group 1 (p=0.01). Postoperative pain (p=0.002) and function (p=0.002) were better in group 1. Mean acetabular abduction angle of the cup was greater in group 1 (p=0.03) and reconstruction to the hip rotation center according to Ranawat (p=0.01) was better in group 2. Placement of the acetabular component inside the Lewinnek´s zone and stem position were similar in both groups. No hips were revised due to complications related to ceramic or to stem loosening. Three cups were revised for aseptic loosening in group 1 and four in group 2. The survival rate for cup aseptic loosening at 15 years was 92.3% (95% CI: 83.7 to 100) for group 1 and 93.1% (95% CI: 85.3 to 99.9) for group 2 (Log rank, p=0.88). Ceramic-on-ceramic uncemented THR is an excellent option for young and very young patients. Despite worse preoperative conditions in patients under the age of 30 years, a similar clinical outcome was found in this series.
The biological response to implant-derived wear particles is recognized as one of the main factors involved in the development of periprosthetic osteolysis. Wear particles induce a foreign-body inflammatory response that results in the formation of a periprosthetic membrane and progresses over time to aseptic loosening and implant failure. Upon exposure to particles, macrophages and other cell types release inflammatory cytokines to the periprosthetic milieu such as inter-leukin-1 beta (IL-1 beta, tumor necrosis factor-alpha (TNF-alpha) and interleukin-6 (IL-6) which contribute to bone resorption. Heat shock proteins (HSP) are intra-cellular proteins involved in the maintenance of cellular homeostasis. The stress inducible form of the Hsp70 family protein, Hsp72, has been detected in circulation, acting as a factor capable of regulating pro-inflammatory cytokines secretion and it has been demonstrated that induces the production of pro-inflammatory cytokines via the CD14 and Toll-like receptor-mediated signal transduction pathway. We hypothesized that Hsp72 could be involved in the inflammatory response to wear particles. To this aim, we investigated Hsp72 and its receptor, CD14, in interfacial membrane specimens obtained from patients undergoing revision surgery for aseptic loosening of uncemented acetabular cups (n=7). Distribution of both proteins was assessed by immunofluorescence and examined by confocal laser scanning microscopy. Hsp72 was detected in the periprostehetic membranes, colocalizing with CD14. Explants of membranes were cultured in vitro and levels of Hsp72 and IL-6 were determined by ELISA after 24, 48 and 72 h (n=9). Cultured membranes released IL-6 to culture medium in a time-dependent manner (p<
0.05), while Hsp72 levels decreased during same observation period (p<
0.05). These data suggest that, rather than being produced by the periprosthetic tissue, Hsp72 might be recruited by CD14+ cells from extracellular fluids. In this regard, preliminary data indicated that soluble Hsp72 levels in sera from patients undergoing revision surgery due to aseptic loosening were significantly lower than those from age-matched control subjects (n=6; p<
0.001). To investigate the involvement of Hsp72 in the inflammatory response to wear particles, we used a cell culture model of THP-1 cells driven to the monocyte/macrophage differentiation pathway. These cells were exposed to titanium particles of phagocytosable sizes, either in the presence or absence of exogenously added Hsp72. results obtained to date indicate that Hsp72 is able to modulate the titanium-induced TNF-alpha, IL-1 beta and IL-6 secretion (p<
0.05). Altogether, our data suggest that Hsp72 could be a novel mediator involved in wear particles-induced osteolysis and prosthetic failure.