Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 158 - 158
1 Jul 2014
Elnikety S Pendegrass C Holden C Blunn G
Full Access

Summary

Our results prove that Demineralised Cortical Bone (DCB) can be used as biological tendon graft substitute, combined with correct surgical technique and the use of suture bone anchor early mobilisation can be achieved.

Introduction

Surgical repair of tendon injuries aims to restore length, mechanical strength and function. In severe injuries with loss of tendon substance a tendon graft or a substitute is usually used to restore functional length. This is usually associated with donor site morbidity, host tissue reactions and lack of remodelling of the synthetic substitutes which may result in suboptimal outcome. In this study we hypothesise that DCB present in biological tendon environment with early mobilisation and appropriate tension will result in remodelling of the DCB into ligament tissue rather that ossification of the DCB at traditional expected. Our preparatory cadaveric study (abstract submitted to CORS 2013) showed that the repair model used in this animal study has sufficient mechanical strength needed for this animal study.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 159 - 159
1 Jul 2014
Elnikety S Pendegrass C Alexander S Blunn G
Full Access

Summary

Our study shows that a tendon rupture can be successfully augmented with Demineralised Cortical Bone (DCB) giving initial appropriate mechanical strength suitable for in vivo use providing the biological reactions to the graft are favourable.

Introduction

Treatment of tendon and ligament injuries remains challenging; the aim is to find a biocompatible substance with mechanical and structural properties that replicate those of normal tendon and ligament. Because of its structural and mechanical properties, we proposed that DCB can be used in repair of tendon and ligament as well as regeneration of the enthesis. DCB is porous, biocompatible and has the potential to be remodelled by the host tissues. 2 studies were designed; in the first we examined the mechanical properties of DCB after gamma irradiation (GI) and freeze drying (FD). In the second we used different techniques for repairing bone-tendon-bone with DCB in order to measure the mechanical performance of the construct.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_19 | Pages 10 - 10
1 Apr 2013
Elnikety S El-Husseiny M Kamal T Gregoras M Talawadekar G Jeer P
Full Access

Introduction

The transtibial approach is widely used for femoral tunnel positioning in ACL reconstruction. Controversy exists over the superiority of this approach over others. Few studies reflected on the reproducibility rates of the femoral tunnel position in relation to the approach used.

Methods

We reviewed AP and Lat X-ray radiographs post isolated ACL reconstruction for 180 patients for femoral tunnel position, tibial tunnel position and graft inclination angle. All patients had their operations performed by one surgeon in one hospital between March 2006 and Sep 2010. All operations were performed using one standard technique using transtibial approach for femoral tunnel positioning. Two orthopaedic fellows, with similar experiences, reviewed blinded radiographs. A second reading was done 8 weeks later. Pearson inter-observer and intra-observer correlation analyses were done using SPSS. Mean age was 29 years (range 16–54).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 35 - 35
1 Mar 2013
Elnikety S Pendegrass C Alexander S Blunn G
Full Access

Repair of tendon injuries aims to restore length, mechanical strength and function. We hypothesise that Demineralised Cortical Bone (DCB) present in biological tendon environment will result in remodelling of the DCB into ligament tissue. A cadaveric study was carried out to optimize the technique. The distal 1cm of the patellar tendon was excised and DCB was used to bridge the defect. 4 models were examined, Model-1: one anchor, Model-2: 2 anchors, Model-3: 2 anchors with double looped off-loading thread, Model-4: 2 anchors with 3 threads off-loading loop. 6 mature sheep undergone surgical resection of the distal 1cm of the right patellar tendon. Repair was done using DCB with 2 anchors. Immediate mobilisation was allowed, animals were sacrificed at 12 weeks. Force plate assessments were done at weeks 3, 6, 9 and 12. Radiographs were taken and pQCT scan was done prior to histological analysis. In the cadaveric study, the median failure force for the 4 models; 250N, 290N, 767N and 934N respectively. In the animal study, none of the specimens showed evidence of ossification of the DCB. One animal failed to show satisfactory progress, X-rays showed patella alta, on specimen retrieval there was no damage to the DCB and sutures and no evidence of anchor pullout. Functional weight bearing was 79% at week12. Histological analysis proved remodelling of the collagen leading to ligamentisation of the DCB. Results prove that DCB can be used as biological tendon substitute, combined with the use of suture bone anchor early mobilisation can be achieved.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 36 - 36
1 Mar 2013
Elnikety S Pendegrass C Alexander S Blunn G
Full Access

Treatment of tendon and ligament injuries remains challenging; the aim is to find a biocompatible substance with mechanical and structural properties that replicate those of normal tendon and ligament. We examined the mechanical properties of Demineralised Cortical Bone (DCB) after gamma irradiation (GI) and freeze drying (FD). We also used different techniques for repairing bone-tendon-bone with DCB in order to measure the mechanical performance of the construct. DCB specimens were allocated into 4 groups; FD, GI, combination of both or none. The maximum tensile forces and stresses were measured. 4 cadaveric models of repair of 1cm patellar tendon defect using DCB were designed; model-1 using one bone anchor, Model-2 using 2 bone anchors, Model-3 off-loading by continuous thread looped twice through bony tunnels, Model-4 off-loading with 3 hand braided threads. Force to failure and mode were recorded for each sample. FD groups results were statistically higher (p=<0.05) compared to non-FD groups, while there was no statistical difference between GI and non-GI groups. The median failure force for model-1: 250N, model-2: 290N, model-3: 767N and model-4: 934N. There was no statistical significance between model-1 and model-2 (p=0.249), however statistical significance was found between other models (p=<0.006). GI has no significant effect on mechanical strength of the CDB while FD may have positive effect on its mechanical strength. Our study shows that a tendon rupture can be successfully augmented with CDB giving initial appropriate mechanical strength suitable for in vivo use providing the biological reactions to the graft are favourable.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 170 - 170
1 Jan 2013
Elnikety S Pendegrass C Blunn G
Full Access

Introduction

Tendon injuries remain challenging, secondary healing and prolonged immobilisation result in suboptimal outcome. Previous study by our group showed that demineralised bone matrix (DBM) can result in faster healing of a tendon enthesis. The aim of this study is to test different ways augmenting tendon with DBM to enhance tendon repair and regeneration.

Methods

DBM strips were prepared from tibias of mature ewes. Patella, patellar tendon and tibias were dissected and the distal 1 cm of the patellar tendon was excised.

4 models were designed;

Model-1, DBM strip was used to bridge the gap between the tendon and the tibial tuberosity. The DBM strip was stitched to the tendon using one bone anchor.

Model-2, similar to model 1 with the use of 2 anchors.

Model-3, similar to model 2, construct was off loaded by continuous thread looped twice through bony tunnels sited in the patella and in the tibial tuberosity.

Model-4, similar to model 3 with 3 threads as off loading loop.

All models were tested for pullout force and mode of failure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 171 - 171
1 Jan 2013
Elnikety S Pendegrass C Blunn G
Full Access

Introduction

Demineralised Bone Matrix (DBM) is widely used in Orthopaedics and dentistry as a bone graft substitute and may be used to augment bone formation in load bearing applications.

In this study we examine the effect of gamma irradiation and freeze drying on the tensile strength of Demineralised Cortical Bone (DCB).

Methods

Tibias were harvested from mature ewes and cut into bony strips. Demineralisation was done using 0.6M HCL and confirmed by X-ray. Specimens were washed until a pH of 7.0 +/_ 0.2 was achieved in the washing solutions.

Specimens were allocated into 4 groups; group (A) non freeze dried non gamma irradiated, group (B) freeze dried non gamma irradiated, group (C) non freeze dried gamma irradiated mention the level of gamma irradiation and group (D) freeze dried and gamma irradiated. The maximum tensile force and stress were measured. Statistical analysis using the Mann-Whitney U test was carried out.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLII | Pages 3 - 3
1 Sep 2012
Elnikety S El-Husseiny M Kamal T Gregoras M Talawadekar G Jeer PJS
Full Access

The transtibial approach is widely used for femoral tunnel positioning in ACL reconstruction. Controversy exists over the superiority of this approach over others. Few studies reflected on the reproducibility rates of the femoral tunnel position in relation to the approach used.

We reviewed AP and Lat X-ray radiographs post isolated ACL reconstruction for 180 patients for femoral tunnel position, tibial tunnel position and graft inclination angle. All patients had their operations performed by one surgeon in one hospital between March 2006 and Sep 2010. All operations were performed using one standard technique using transtibial approach for femoral tunnel positioning.

Two orthopaedic fellows, with similar experiences, reviewed blinded radiographs. A second reading was done 8 weeks later. Pearson inter-observer, intra-observer correlation and Bland-Altman agreements plots statistical analyses were done.

Mean age was 29 years (range 16–54), Pearson intra-observer correlation shows substantial to perfect agreement while Pearson's inter-observer correlation shows moderate to substantial agreement.

Previous literature proved that optimal femoral tunnel position for the best clinical and biomechanical outcome is for the centre of the tunnel to be at 43% from the lateral end of the width of the femoral condyles on the AP view and at 86% from the anterior end of the Blumensaat's line on the lateral view. In our study 85% of the femoral tunnels were within +/− 5% of the optimal tunnel position on the AP views, and more than 70% of the femoral tunnels were within +/−5% of the optimal tunnel position on the Lateral view. Interobserver and intraobserver corelations show moderate to substantial agreement, Bland-Altman agreement plots show substantial agreements for interobserver and intraobserver measurements. These results were found to be statistically significant at 0.01

Based on our results we conclude that using one standardised transtibial technique for ACL reconstruction can result in high reproducibility rates of optimal femoral tunnel position. Further studies are needed to validate our results and to study the reproducibility rates for different approaches and techniques.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 136 - 136
1 Sep 2012
El-Husseiny M Pendegrass C Elnikety S Haddad F Blunn G
Full Access

Introduction

Following amputation, residual stumps used to attach the external prostheses can be associated with sores, infection and skin necrosis. These problems could be overcome by off loading the soft tissues. Intraosseous transcutaneous amputation prostheses (ITAP) attach external implants directly to residual bone reducing these complications. However, a tight seal at the skin implant interface is crucial in preventing epithelial down-growth and infection. Fibronectin (Fn) and laminin 332 (Ln), enhance early cell growth and adhesion of keratinocytes. Silanization to titanium alloy (Ti) allows these proteins to bond to the metal directly. We hypothesize that silanized dual coatings of fibronectin and laminin (SiFnLn) will be more durable than absorbed proteins and that keratinocyte adhesion will be increased compared with Ti controls and single silanized proteins.

Methods

10 mm diameter Ti alloy discs were polished, sterilized and silanized. The kinetics of silanized single and dual protein coating attachment onto titanium alloy was quantified using radio-labelled Fn(125I-Fn) and Ln(125I-Ln). Coating durability was assessed when soaked in fetal calf serum (FCS) for 0, 1, 24, 48, 72hrs. Data was compared to un-silanized Ti discs with the same amount of adsorbed proteins. In order to study cell attachment 20 × 103 keratinocytes were seeded on the discs (n = 6): silanized (Si), silanized fibronectin (SiFn), silanized laminin (SiLn), silanized dual coating (SiFnLn) for 1, 4 and 24hrs. Adhesion of cells was assessed using mouse vinculin antibody for 2hrs and alexafluor for 1hr which stains focal adhesions responsible for attaching cells to surfaces. Axiovision Image Analysis software was used to measure cell area, vinculin markers per cell unit and per unit cell area on 15 cells per disc. Data was analysed in SPSS and significance was assumed at the 0.05 level.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 135 - 135
1 Sep 2012
Elnikety S El-Husseiny M Kamal T Talawadekar G Triggs N Richards H Smith A
Full Access

Introduction

“No routine post-operative follow up appointments” policy has been implemented in NHS hospitals in different specialties for uncomplicated surgical procedures. In trauma and orthopaedics few studies to date reviewed this practice and reflected on the patients' opinions.

Methods

A total of 121 patients were recruited over 2 years, each patient had post operative follow up by the hand therapist for 3 months. 50 patients post Trapeziectomy and 71 patients post single digit Dupuytren's fasciectomy were prospectively surveyed for their opinion on their post operative care and whether they would have liked to be reviewed by the surgeon in a routine post operative follow up appointment or not. All operations were done by one surgeon in one hospital. All patients were reviewed by a hand therapist within 2 weeks post operatively and treatment protocols were followed with all the patients. During their final appointment with the hand therapist all patients completed a questionnaire.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 78 - 78
1 Jul 2012
Talawadekar G Rose B Elnikety S Grigoras I Jeer P
Full Access

Introduction

As intra-operative fluoroscopic identification of the isometric MPFL attachment to the femur can be imprecise and laborious in a surgical setting, we used clinical criteria to identify the isometric point and then studied post-operative radiographs to find out whether it was achieved and compared it with functional outcome.

Materials and Methods

Sixteen patients underwent 17 MPFL reconstructions using autologous semi-tendinosis tendon graft. Clinical judgement was used to identify the optimal point for femoral attachment of the MPFL without fluoroscopy control. Post-operative radiographs at 2 weeks were analysed to confirm whether an isometric point for the reconstructed MPFL was achieved by dividing the distal femur into 4 quadrants by 2 lines on the lateral radiograph. Telephonic interview was conducted to assess functional scores using the Kujala score at a mean follow-up of 13 months.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 59 - 59
1 Jun 2012
Elnikety S
Full Access

In this study we reviewed all Total Elbow Replacements (TER) done in our hospital over eight years period (1997 – 2005), 21 patients (16 females, 5 males) were available for follow up and four were lost (two died and two moved out of the region) with average age of 65 years (range 44 – 77), all procedures were done by two upper limb surgeons (CHB & RGW). 16 patients (14 females, 2 males) had the procedure for Rheumatoid Arthritis and 5 patients (3 males, 2 females) undergone the procedure for post-traumatic arthritis.

The average follow up was 61 months (range 12 – 120 months), the Mayo Clinic performance index, the DASH scores and activities of daily living (adopted from Secec Elbow Score) assessment tools were used. In addition, all patients were assessed for loosening using standard AP and lateral radiographs. Sixteen patients had Souter-Starthclyde prosthesis whilst three had Kudo and two had Conrad-Moorey prosthesis.

All procedures were done through dorsal approach and all were cemented, the ulnar nerve was not transposed in any of the cases. The average elbow extension lag was 27 degrees (range 15 – 35) with flexion up to 130 degrees (range 110 – 140). Supination was 65 degrees (range 15 – 90) and pronation was 77 (range 55 – 90). The average DASH score was 51.3 (range 19 – 95), the Mayo elbow score was 82 (range 55 – 100) and the average Activities of daily living Secec Score was 17 (range 10 – 20).

There were four complications, three ulnar nerve paresis which recovered and one wound complication which needed a flap cover. Two needed revision surgery, one for a periprosthetic fracture and one for loosening. Two patients showed radiological signs of loosening but were asymptomatic. The survival rate with revision as the end point is 95% for aseptic loosening and 90% for any other reason.

Our study proves TER has good medium term results with good functional outcome and high patient satisfaction rate.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVI | Pages 7 - 7
1 Apr 2012
Elnikety S Singh BI Kamal T El-Husseiny M Brooks CH Wetherell RG
Full Access

In this study we reviewed all Total Elbow Replacements (TER) done in our hospital over eight years period (1997 – 2005), 21 patients (16 females, 5 males) were available for follow up and four were lost (two died and two moved out of the region) with average age of 65 years (range 44 – 77), all procedures were done by two upper limb surgeons (CHB & RGW). 16 patients (14 females, 2 males) had the procedure for Rheumatoid Arthritis and 5 patients (3 males, 2 females) undergone the procedure for post-traumatic arthritis.

The average follow up was 61 months (range 12 – 120 months), the Mayo Clinic performance index, the DASH scores and activities of daily living (adopted from Secec Elbow Score) assessment tools were used. In addition, all patients were assessed for loosening using standard AP and lateral radiographs. Sixteen patients had Souter-Starthclyde prosthesis whilst three had Kudo and two had Conrad-Moorey prosthesis.

All procedures were done through dorsal approach and all were cemented, the ulnar nerve was not transposed in any of the cases. The average elbow extension lag was 27 degrees (range 15 – 35) with flexion up to 130 degrees (range 110 – 140). Supination was 65 degrees (range 15 – 90) and pronation was 77 (range 55 – 90). The average DASH score was 51.3 (range 19 – 95), the Mayo elbow score was 82 (range 55 – 100) and the average Activities of daily living Secec Score was 17 (range 10 – 20).

There were four complications, three ulnar nerve paresis which recovered and one wound complication which needed a flap cover. Two needed revision surgery, one for a periprosthetic fracture and one for loosening. Two patients showed radiological signs of loosening but were asymptomatic. The survival rate with revision as the end point is 95% for aseptic loosening and 90% for any other reason.

Our study proves TER has good medium term results with good functional outcome and high patient satisfaction rate.