Bone & Joint Open
Vol. 2, Issue 8 | Pages 679 - 684
2 Aug 2021
Seddigh S Lethbridge L Theriault P Matwin S Dunbar MJ

Aims

In countries with social healthcare systems, such as Canada, patients may experience long wait times and a decline in their health status prior to their operation. The aim of this study is to explore the association between long preoperative wait times (WT) and acute hospital length of stay (LoS) for primary arthroplasty of the knee and hip.

Methods

The study population was obtained from the provincial Patient Access Registry Nova Scotia (PARNS) and the Canadian national hospital Discharge Access Database (DAD). We included primary total knee and hip arthroplasties (TKA, THA) between 2011 and 2017. Patients waiting longer than the recommended 180 days Canadian national standard were compared to patients waiting equal or less than the standard WT. The primary outcome measure was acute LoS postoperatively. Secondarily, patient demographics, comorbidities, and perioperative parameters were correlated with LoS with multivariate regression.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 3 - 3
1 Aug 2020
Seddigh S Dunbar MJ Douglas J Lethbridge L Theriault P
Full Access

Currently 180 days is the target maximum wait time set by all Canadian provinces for elective joint replacement surgery. In Nova Scotia however, only 34% of Total Knee Arthroplasties (TKA) and 51% of Total Hip Arthroplasties (THA) met this benchmark in 2017. Surgery performed later in the natural history of disease is shown to have significant impact on pain, function and Health related Quality of Life at the time of surgery and potentially affect post-operative outcomes. The aim of this study is to describe the association between wait time and acute hospital Length of Stay (LOS) during elective hip and knee arthroplasty in province of Nova Scotia. Secondarily we aim to describe risk factors associated with variations in LOS.

Data from Patient Access Registry Nova Scotia (PAR-NS) was linked to the hospital Discharge Access Database (DAD) for primary hip and knee arthroplasty spanning 2009 to 2017. There were 23,727 DAD observations and 21,329 PARNS observations identified. Observations were excluded based on missing variables, missing linkages, revision status and emergency cases. Percentage difference in LOS, risk factors and outcomes were analyzed using Poisson regression for those waiting more than 180 days compared to those waiting equal or less than 180 days.

For primary TKA, 11,833 observations were identified with mean age of 66 years, mean wait time of 348 days and mean LOS of 3.6 days. After adjusting for controls, patients waiting more than 180 days for elective TKA have a 2.5% longer acute care LOS (p < 0.028). Risk factors identified for prolonged LOS are advanced age, female gender, higher surgical priority indicator, required blood transfusion, dementia, peptic ulcer disease, cerebrovascular disease, heart failure, chronic kidney disease, malignancy, ischemic heart disease and diabetes. Factors associated with decreased LOS are surgical year, use of local anesthetic, peripheral location of hospital and admission to hospital from home.

For primary THA, 6626 observations were identified with mean age of 66 years, mean wait time of 267 days and mean LOS of 4 days. Patients waiting more than 180 days for THA did not show a statistically significant association with LOS. Risk factors and protective factors are the same with exception of CVD and use of local anesthetic.

Our findings suggest a positive and statistically significant association for patients waiting more than 180 days for TKA and longer acute care LOS. Longer LOS may be due to deteriorating health status while placed on a surgical waitlist and may represent a delayed and indirect cost to the patient and the healthcare system. Ultimately with projected increase in demand for elective joint replacement surgeries, our findings are aimed to inform physicians and policy makers in management of surgical waitlist efficiency and cost effectiveness.

For any reader inquiries, please contact shahriar-s@hotmail.com


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 43 - 43
1 Aug 2020
Laende E Dunbar MJ Richardson G
Full Access

The dual mobility design concept for acetabular components is intended to reduce the risk of dislocation and increase range of motion, but the wear pattern of this design is unclear and may have implications in implant fixation. Additionally, the solid back cups do not have the option for supplementary screw fixation, providing an additional smooth articulating surface for the liner to move against. The objective of this study was to assess cup fixation by measuring implant migration as well as proximal femoral head penetration to evaluate wear performance.

Thirty subjects were recruited in a consecutive series prospective study and received dual mobility uncemented acetabular components with mobile bearing polyethylene liners through a direct lateral approach. Femoral stems were cemented or uncemented. All subjects had 28 mm femoral heads. The femur, acetabulum, and non-articulating surface of the mobile polyethylene liner were marked with tantalum beads. Radiostereometric analysis (RSA) exams were performed post-operatively and at 6 weeks, 3 months, 6 months, 1 year, 2 years, and 3 years. Oxford 12 Hip and Satisfaction questionnaire responses were recorded. Mobile bearing motion was assessed under fluoroscopy for a single case under loaded and unloaded conditions.

Twenty-nine subjects (17 female) proceeded to surgery. Subjects were 63±11 years of age with BMIs of 28±4.7 kg/m2. Cup migration reached 0.16 ± 0.31 mm of proximal translation and 0.29±1.03 degrees of sagittal rotation at three years. A single individual had more than 3 degrees of cup rotation, occurring by 6 months and not substantially increasing after this time. Proximal translation was low for this subject. Wear of the highly cross-linked mobile bearings was 0.18 ± 0.30 mm of proximal femoral head penetration from 0 to 3 years. The mean wear rate from 1 to 3 years was 0.02 mm/year. One subject was an outlier for wear, with more than 1 mm of femoral head penetration at 1 year. However, wear did not increase after 1 year for this subject and cup migrations were below average for this individual. Similarly, the outlier for cup rotation had below average wear. Satisfaction (out of 100%) improved from 25±27% to 96±7% pre-operatively to 3 years post-operatively. Oxford 12 scores (best possible score of 48) improved from 21±7 to 43±7 over the same period. The fluoroscopic case study demonstrated visible motion of the mobile bearing during hip rotation tasks.

The overall migration of the cup was low and demonstrated favorable patterns suggesting low risk of aseptic loosening. Wear rates are also within the expected range of 0 to 0.06 mm/year for highly cross-linked polyethylene. The combination of low subsidence and low sagittal rotations of the cup, and low wear of the polyethylene are favorable predictors of good long-term performance.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 22 - 22
1 Aug 2020
Sandoval C Di Bella J Dragan A de Guia N Webster G Dunbar MJ Bohm E Yu C
Full Access

Revision is a key negative outcome of joint replacements. The purpose of this abstract is to present revision risk curves for hip and knee replacements based on the most recently available national data sources. Having a better understanding of determinants of revision risk can help inform clinical and health care system improvements.

We explored revision risk of primary joint replacement stratified by key clinical, prosthesis, and surgeon-level factors using data from three databases managed by CIHI: the Canadian Joint Replacement Registry (CJRR), the Discharge Abstract Database, and the National Ambulatory Care Reporting System. To investigate early revisions, we used Kaplan-Meier analysis stratified by demographic factors to determine the risk of revision within up to five years of primary surgery. This analysis identified the primary cohort from the CJRR from April 1, 2012 to March 31, 2017 and was limited to mandatory reporting provinces (British Columbia, Manitoba and Ontario) to ensure maximal coverage of prosthesis information. Bearing surface was obtained from the International Prosthesis Library maintained by the International Consortium of Orthopaedic Registries (ICOR) and the International Society of Arthroplasty Registers (ISAR).

The total revision risk cohort contained 283,620 primary surgeries, of which 5,765 (2%) had at least one revision. For total hip arthroplasties, revision risk at the end of the follow-up period did not differ by age, by sex or across bearing surface (metal on cross-linked polyethylene [XLPE], ceramic on XLPE, ceramic on ceramic, metal on non-cross-linked polyethylene). For hemiarthroplasties in hip fracture patients, cement fixation was significantly associated with decreased revision risk. Surgeon volume had a positive effect on survivorship with cementless fixation (2.7% at one year [95% CI 2.3%, 3.1%] for high-volume vs 3.2% [2.7%, 3.7%] for low-volume). However, surgeon volume did not have an effect on survivorship with cemented fixation (2% at one year [95% CI 1.3%, 2.6%] for high-volume vs. 2% [1.4%, 2.6%] for low-volume). For total knee replacements, revision risk increased with decreasing age and male sex. For patients aged 75 and older, four-year revision risks were 1.5% (95% CI 1.3%, 1.7%) for women and 2.0% (1.7%, 2.3%) for men, but for patients under 55 years old, they were 4.3% (3.7%, 5%) for women and 5.9% (4.9%, 6.9%) for men. Additional results from the upcoming 2019 CJRR annual report, including data up to March 31, 2018, will be presented.

Revisions represent a key failure of the primary replacement, they are costly to the health care system and negatively affect patients' quality of life. CJRR's coverage is currently 72%, increased coverage and follow-up time will allow increasingly comprehensive reporting on hip and knee prostheses in Canada. Future work in this area involves exploring additional prosthesis attributes for stratification of revision risk curves and calculation of hazards ratios adjusted by age and sex.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 27 - 27
1 Jul 2020
Hurry J Spurway A Dunbar MJ El-Hawary R
Full Access

Radiostereometric analysis (RSA) allows for precise measurement of interbody distances on X-ray images, such as movement between a joint replacement implant and the bone. The low radiation biplanar EOS imager (EOS imaging, France) scans patients in a weight-bearing position, provides calibrated three-dimensional information on bony anatomy, and could limit the radiation during serial RSA studies. Following the ISO-16087 standard, 15 double exams were conducted to determine the RSA precision of total knee arthroplasty (TKA) patients in the EOS imager, compared to the standard instantaneous, cone-beam, uniplanar digital X-ray set-up.

At a mean of 5 years post-surgery, 15 TKA participants (mean 67 years, 12 female, 3 male) were imaged twice in the biplanar imager. To reduce motion during the scan, a support for the foot was added and the scan speed was increased. The voltage was also increased compared to standard settings for better marker visibility over the implant. A small calibration object was included to remove any remaining sway in post-processing.

The 95% confidence interval precision was 0.11, 0.04, and 0.15 mm in the x, y, and z planes, respectively and 0.15, 0.20, and 0.14° in Rx, Ry, and Rz. Two participants had motion artifacts successfully removed during post-processing using the small calibration object.

With faster speeds and stabilization support, this study found an in vivo RSA precision of ≤ 0.15 mm and ≤ 0.20° for TKA exams, which is within published uniplanar values for arthroplasty RSA. The biplanar imager also adds the benefits of weight bearing imaging, 3D alignment measurements, a lower radiation dose, and does not require a reference object due to known system geometry and automatic image registration.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 14 - 14
1 Jul 2020
Young K Wilson JA Dunbar MJ Roy P Abidi S
Full Access

Identifying knee osteoarthritis (OA) patient phenotypes is relevant to assessing treatment efficacy, yet biomechanical variability has not been applied to phenotyping. This study aimed to identify demographic and gait related groups (clusters) among total knee arthroplasty (TKA) candidates, and examine inter-cluster differences in gait feature improvement post-TKA.

Knee OA patients scheduled for TKA underwent three-dimensional gait analysis one-week pre and one-year post-TKA, capturing lower-limb external ground reaction forces and kinematics using a force platform and optoelectronic motion capture. Principal component analysis was applied to frontal and sagittal knee angle and moment waveforms (n=135 pre-TKA, n=106 post-TKA), resulting in a new uncorrelated dataset of subject PCscores and PC vectors, describing major modes of variability throughout one gait cycle (0–100%). Demographics (age, gender, body mass index (BMI), gait speed), and gait angle and moment PCscores were standardized and assessed for outliers. One patient exceeding Tukey's outer (3IQR) fence was removed. Two-dimensional multidimensional scaling followed by k-medoids clustering was applied to scaled demographics and pre-TKA PCscores [134×15]. Number of clusters (k=2:10) were assessed by silhouette coefficients, s, and stability by Adjusted Rand Indices (ARI) of 100 data subsets. Clusters were validated by examining inter-cluster differences at baseline, and inter-cluster gait changes (PostPCscore–PrePCscore, n=105) by k-way ANOVA and Tukey's honestly significant difference (HSD) criterion.

Four (k=4) TKA candidate groups yielded optimum clustering metrics (s = 0.4, ARI=0.75). Cluster 1 was all-males (male:female=19:0) who walked with faster gait speeds (1>2,3), larger flexion angle magnitudes and stance-phase angle range (PC1 & PC4 1>2,3,4), and more flexion (PC2 1>2,3,4) and adduction moment (PC2 & PC3 1>2,3) range patterns. Cluster 1 had the most dynamic kinematics and kinetic loading/unloading range amongst the clusters, representing a higher-functioning (less “stiff”) male subset. Cluster 2 captured older (2>1,3) males (31:1) with slower gait speeds (2 4), and lower flexion angle magnitude (PC1 3 2,3) and less stiff kinematic and kinetic patterns relative to Clusters 2 and 3, representing a higher-functioning female subset. Radiographic severity did not differ between clusters (Kellgren-Lawrence Grade, p=0.9, n=102), and after removing demographics and re-clustering, gender differences remained (p < 0 .04). Pre-TKA, higher-functioning clusters (1&4) had more dynamic loading/un-loading kinetic patterns. Post-TKA, high-functioning clusters experienced less gait improvement (flexion angle PC2, 1,4 < 3, p≥0.004, flexion moment PC2, 4 < 2,3), with some sagittal range patterns decreasing postoperatively.

TKA candidates can be characterized by four clusters, differing by demographics and biomechanical severity features. Post-TKA, functional gains were cluster-specific, stiff-gait clusters experienced more improvement, while higher-functioning clusters experienced less gain and showed some decline. Results suggest the presence of cohorts who may not benefit functionally from TKA. Cluster profiling may support triaging and developing targeted OA treatment strategies, meeting individual function needs.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 142 - 142
1 Jul 2020
Wilson J Outerleys J Wilson D Richardson G Dunbar MJ
Full Access

Up to 20 percent of patients remain dissatisfied after primary total knee arthroplasty (TKA) surgery. Understanding the reasons for dissatisfaction post TKA may allow for better patient selection and optimized treatment for those who remain dissatisfied. The association between function, mobility and satisfaction are not well understood. The purpose of this study was to investigate the association between post-TKA satisfaction and i) pre-operative, ii) post-operative, and iii) change in knee joint function during gait.

Thirty-one patients scheduled to receive primary TKA for knee osteoarthritis (OA) diagnosis were recruited and visited the Dynamics of Human Motion laboratory for instrumented walking gait analysis (using a synchronized NDI Optotrak motion capture system and AMTI force platforms in the walkway) at two time points, first within the week prior to their surgery, and second at approximately one year after surgery. At their post-operative visit, patients were asked to indicate their satisfaction with their knee prosthesis on a scale from zero to 100, with zero being totally unsatisfied and 100 being completely satisfied. Knee joint mechanics during gait at both time points were characterized by discriminant scores, the projection of their three-dimensional knee angles and moments during gait onto an existing discriminant model that was created to optimize separation of severe knee OA and healthy asymptomatic gait patterns. This discriminant model was created using data from 73 healthy participants and 73 with severe knee OA, and includes the magnitude and pattern features (captured with principal component analysis) of the knee adduction and flexion moment, and the magnitude of the knee flexion angle during gait. Larger discriminant scores indicate improved function toward healthy patterns, and smaller scores indicate more severe function. Associations between post-operative satisfaction and pre, post and change in discriminant scores were examined using Pearson correlation analyses. We also examined associations between satisfaction and pre-operative BMI, EQ5D and Oxford 12 scores, as well as changes in these scores from pre to post-TKA.

Discriminant scores representing knee joint function during gait significantly improved on average after surgery (P =0.05).

While overall knee joint function improved after primary TKA surgery, the amount of improvement in function was not reflected in post-operative patient satisfaction. However, the pre-operative function of the patient was negatively associated with satisfaction, indicating that patients with higher pre-operative function are overall less satisfied with their TKA surgery, regardless of any functional improvement due to the surgery. Interestingly, the only significant association with post-operative satisfaction was knee joint function, and the relationship between function and patient satisfaction following TKA appears to relate only to the baseline functional state of the patient, and not with functional improvement. This suggests that dissatisfaction post-surgery is more likely reflecting the unmet expectations of a higher functioning patient, and has implications for the need for improved understanding of pre-operative patient functional variability in TKA triage and expectation management.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 49 - 49
1 Jul 2020
Gascoyne T Parashin S Teeter M Bohm E Laende E Dunbar MJ Turgeon T
Full Access

The purpose of this study was to examine the influence of weight-bearing on the measurement of in vivo wear of total knee replacements using model-based RSA at 1 and 2 years following surgery.

Model-based RSA radiographs were collected for 106 patients who underwent primary TKR at a single institution. Supine RSA radiographs were obtained post-operatively and at 6-, 12-, and 24-months. Standing (weight-bearing) RSA radiographs were obtained at 12-months (n=45) and 24-months (n=48). All patients received the same knee design with a fixed, conventional PE insert of either a cruciate retaining or posterior stabilized design. Ethics approval for this study was obtained.

In order to assess in vivo wear, a highly accurate 3-dimensional virtual model of each in vivo TKA was developed. Coordinate data from RSA radiographs (mbRSA v3.41, RSACore) were applied to digital implant models to reconstruct each patient's replaced knee joint in a virtual environment (Geomagic Studio, 3D Systems). Wear was assessed volumetrically (digital model overlap) on medial and lateral condyles separately, across each follow-up. Annual rate of wear was calculated for each patient as the slope of the linear best fit between wear and time-point. The influence of weight-bearing was assessed as the difference in annual wear rate between standing and supine exams. Age, BMI, and Oxford-12 knee improvement were measured against wear rates to determine correlations.

Weight bearing wear measurement was most consistent and prevalent in the medial condyle with 35% negative wear rates for the lateral condyle. For the medial condyle, standing exams revealed higher mean wear rates at 1 and 2 years, supine, 16.3 mm3/yr (SD: 27.8) and 11.2 mm3/yr (SD: 18.5) versus standing, 51.3 mm3/yr (SD: 55.9) and 32.7 mm3/yr (SD: 31.7). The addition of weight-bearing increased the measured volume of wear for 78% of patients at 1 year (Avg: 32.4 mm3/yr) and 71% of patients at 2 years (Avg: 48.9 mm3/yr). There were no significant (95% CI) correlations between patient demographics and wear rates.

Volumetric, weight-bearing wear measurement of TKR using model-based RSA determined an average of 33 mm3/yr at 2 years post-surgery for a modern, non-cross-linked polyethylene bearing. This value is comparable to wear rates obtained from retrieved TKRs. Weight-bearing exams produced better wear data with fewer negative wear rates and reduced variance. Limitations of this study include: supine patient imaging performed at post-op, no knee flexion performed, unknown patient activity level, and inability to distinguish wear from plastic creep or deformation under load. Strengths of this study include: large sample size of a single TKR system, linear regression of wear measurements and no requirement for implanted RSA beads with this method. Based on these results, in vivo volumetric wear of total knee replacement polyethylene can be reliably measured using model-based RSA and weight-bearing examinations in the short- to mid–term. Further work is needed to validate the accuracy of the measurements in vivo.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 46 - 46
1 Oct 2019
Young-Shand KL Roy PC Dunbar MJ Abidi SSR Astephen-Wilson JL
Full Access

Introduction

Identifying knee osteoarthritis patient phenotypes is relevant to assessing treatment efficacy. Biomechanical variability has not been applied to phenotyping, yet features may be related to outcomes of total knee arthroplasty (TKA), an inherently mechanical surgery. This study aimed to i) identify biomechanical phenotypes among TKA candidates based on demographic and gait mechanic similarities, and ii) compare objective gait improvements between phenotypes post-TKA.

Methods

TKA patients underwent 3D gait analysis one-week pre (n=134) and one-year post-TKA (n=105). Principal component analysis was applied to frontal and sagittal knee angle and moment gait waveforms, extracting major patterns of variability. Demographics (age, sex, BMI), gait speed, and frontal and sagittal pre-TKA angle and moment principal component (PC) scores previously found to differentiate sex, osteoarthritis (OA) severity, and symptoms of TKA recipients were standardized (mean=0, SD=1, [134×15]) to perform multidimensional scaling and machine learning based hierarchical clustering. Final clusters were validated by examining inter-cluster differences at baseline and gait changes (PostPCscore–PrePCscore) by k-way Chi-Squared, and ANOVA tests.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 26 - 26
1 Oct 2018
Dunbar MJ Laende E Richardson CG
Full Access

Introduction

Cementless fixation in total knee arthroplasty has been proposed to offer advantages long-term once osteointegration has occurred as there is no substrate between the implant and the bone to fail. Radiostereometric analysis (RSA) is a useful tool to study fixation, but typically focused on early migration in the first two post-operative years. Few studies have looked at 10-year RSA migration in cementless fixation and those that have contain small numbers of subjects. The objective of this study was to compare implant migration and inducible displacement between cemented and cementless TKA at 10 years and to compare the 10-year migration to the 2-year data in an effort to validate the predictive modelling of RSA.

Methods

Subjects who had previously participated in RSA migration studies with 2-year follow-up were recruited to return for a long-term follow-up exam, at least 10 years from their surgery. The implants under study included two cemented designs from two manufacturers and one porous metal monoblock cementless design. At the 10-year visit, subjects had supine RSA exams to determine long-term migration as well as a loaded exam (single leg stance) to determine inducible displacement. Differences between cemented and cementless groups were evaluated with the Mann Whitney U test and Spearman's rank correlation coefficients were calculated for early and late migrations. Significance was set at p < 0.05.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 158 - 158
1 Sep 2012
Hennigar A Gross M Amirault D Laende E Dunbar MJ
Full Access

Purpose

To determine if minimally invasive surgery (MIS) for primary hip replacement surgery increases the risk of long term aseptic loosening as predicted by implant micromotion measured with radiostereometric analysis (RSA).

Method

Ninety patients undergoing primary THA for osteoarthritis (exclusion criteria: post-traumatic arthritis, rheumatoid arthritis, hip dysplasia, previous hip infection) were randomized to undergo THR surgery utilizing the standard direct lateral approach (n=45; 24 male; age=58 yrs; BMI=27) or MIS via a one-incision direct lateral approach using specific instrumentation (n=45; 23 male; age=55; BMI=29). Uncemented acetabular and femoral (ProfemurZ) components were used with ceramic on ceramic bearings. The femur was marked with 9 tantalum beads placed in the greater trochanter, lesser trochanter, and femoral shaft distal to the tip of the prosthesis. Post-operative care was be standardized according to the care maps at our institution. Primary outcome measure was femoral stem MTPM (maximum total point motion) measured using Model-based RSA. Stereo supine X-rays were taken before weight bearing and 3, 6, and 12 months postoperatively. At the same time intervals Harris Hip Score, Oxford-12, WOMAC, and SF36 questionnaires were administered. Rates of infection, dislocation and revision were recorded.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 186 - 186
1 Sep 2012
Fong J Dunbar MJ Wilson DA Hennigar A Francis P Glazebrook M
Full Access

Purpose

The purpose of this study was to assess the clinical outcomes over two years for total ankle arthroplasty (TAA) using Short Form-36, Foot Function Index and Ankle Osteoarthritis Scores, and to compare these with radiostereometric analysis longitudinal migration and inducible displacement results.

Method

Twenty patients undergoing TAA implanting the Mobility Total Ankle System (DePuy, Warsaw IN) were assessed at 3mth, 6mth, 1yr and 2yr followup periods by model-based radiostereometric analysis, MBRSA 3.2 (Medis specials, Leiden, The Netherlands), for longitudinal migration (LM) and inducible displacement (ID). The same subjects completed clinical outcome questionnaires at these followup periods for Short Form-36 (SF-36; Physical Component Scores (PCS) and Mental Component Scores (MCS)), Foot Function Index (FFI) and Ankle Osteoarthritis Scores (AOS). Descriptive statistics and Pearson correlations (alpha = 0.05) were calculated using Minitab 15 (Minitab Inc., State College PA).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 46 - 46
1 Sep 2012
Fong J Dunbar MJ Wilson DA Hennigar A Francis P Glazebrook M
Full Access

Purpose

The purpose of this study was to assess the biomechanical stability of the a total ankle arthroplasty system using longitudinal migration (LM) and inducible displacement (ID) measures. This study is the first study of its kind to assess total ankle arthroplasty (TAA) implant micromotion using model-based radiostereometric analysis (MBRSA).

Method

Twenty patients underwent TAA that implanted the Mobility(TM) (DePuy, Warsaw IN). The mean (SD) age was 60.4 (12.5) and BMI was 29.1 (2.8) kg/m2. One surgeon performed all surgeries. All patients included in this study had given informed consent. Capital Health Research Ethics Board had approved this study.

Uniplanar medial-lateral RSA X-ray exams were taken postop (double exam), at six wk, three mth, six mth, one yr and two yr followup times using a supine, unloaded position. Standing medial-lateral exams were taken at three mth, six mth, one yr and two yr followup intervals.

LM and ID micromotions were assessed using Model-based RSA 3.2 software (Medis specials, Leiden, The Netherlands). Implant micromotions (x, y, z, Rx, Ry, Rz, MTPM) were determined and assessed for each subject using model-based pose estimation, and the implant-based coordinate system. The Elementary Geometric Shapes module from the Model-based RSA 3.2 software was used to assess the micromotion of the tibial component spherical tip due to implant symmetry.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 47 - 47
1 Sep 2012
Wilson JA Dunbar MJ
Full Access

Purpose

To characterize the knee kinematic profiles of total knee arthroplasty patient knees intraoperatively, before implant insertion, using principal component analysis.

Method

Ninety-two patientsreceived Stryker Triathlon total knee arthroplasty (TKA) implants. The Stryker surgical navigation system was used for all surgeries. The system was used to define rigid bodies representing the femur and tibia, and to track the three-dimensional movement of the knee joint during surgery. Each knee was moved through a passive range of knee flexion/extension before and after implantation of the arthroplasty components. The frontal plane (medial-lateral) movement of the knee joint through a range of 10 to 120 degrees of flexion before implantation was calculated for each knee using the joint coordinate system (referred to as the pre-implant knee kinematic curve). Visual inspection of these patterns indicated three predominant curve types: a backward S shape, a backward C shape and a valgus to varus shape. Each curve was subjectively categorized into one of these three categories. Principal component analysis (PCA), a multivariate statistical analysis technique, was applied to the pre-implant knee kinematic pattern data to objectively extract the major patterns of curve types within the 92 knees. Analysis of variance was used to compare the mean differences in PC scores between the curve shape groups to confirm visual categorization.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 49 - 49
1 Sep 2012
Konadu D Wilson JA Dunbar MJ Laende E Hennigar A Gross M
Full Access

Purpose

Aseptic loosening of the tibial component of total knee prosthesis is a common cause of revision surgery. While micromotion at the bone-implant interface can now be accurately measured with Radiostereometric Analysis (RSA), mechanisms responsible for loosening remain poorly understood. The purpose of this study was to investigate the association between bone density in the proximal tibia and post-operative knee implant migration.

Method

Fifty-one subjects who received total knee arthroplasty surgery with the Wright Medical Advance Biofoam (uncemented) implant were recruited. Bone density of seven regions of the proximal tibia (medial, lateral, anterior, posterior, and three regions below implant tip) was measured with DEXA post operatively at two, six, 12 and 24 weeks. RSA exams were also taken immediately post-operatively, and at six, 12 and 24 weeks. Correlations between bone mineral density and RSA migration were examined at 24 weeks post-operatively.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 89 - 89
1 Sep 2012
Amirault DJ Gross M Hennigar A Laende E Dunbar MJ
Full Access

Purpose

The foam metal backed Advance BioFoam Knee Arthroplasty components utilize a porous titanium coating on the underside of the tibial baseplate, intended to promote bone in-growth and provide a more robust bone-implant interface without cement. There is also a version of the Biofoam Advance that incorporates screwed fixation that allows for augmented fixation with up to four titanium screws; however, it is not clear that this augmentation is necessary. The purpose of this study was to employ radiostereometric analysis (RSA) to compare implant migration in a randomized controlled trial of this implant design with or without screw fixation.

Method

Fifty-one patients were randomized to receive a BioFoam total knee replacement (Wright Medical Technologies) with or without screw fixaiton. During surgery, eight tantalum markers, one millimetre in diameter, were inserted into the proximal tibia. Using a calibration box, stereo RSA radiographs were taken post-operatively and then again at six weeks and three, six and 12 months following surgery. Model Based RSA was used with 3D models of the tibial component to measure migration. Health status and functional outcome measures were recorded to quantify functional status of subjects before surgery and at each follow-up interval.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 93 - 93
1 Sep 2012
Wilson DA Dunbar MJ Richardson G Hennigar A
Full Access

Purpose

To evaluate the five year Radiostereometric Analysis (RSA) results of the NexGen LPS Trabecular Metal Tibial Monoblock component (TM) and the NexGen Option Stemmed cemented component (Cemented), (Zimmer, Warsaw IN).

Method

70 patients with osteoarthritis were included in a randomized series to receive either the TM implant or the cemented NG component. Surgery was performed by high volume arthoplasty specialists using standardized procedure. RSA exams were obtained postoperatively, at six months, one year, two years and five years. RSA outcomes were translations, rotations and maximum total point motion (MTPM) of the components. MTPM values were used to classify implants as ‘at risk’ or ‘stable’. Western Ontario and McMaster University Osteoarthritis Index (WOMAC) scores were gathered at all follow-ups.

An analysis of variance was used to test for differences in age, body mass index (BMI), and subjective measures between implant groups. The Kruskal-Wallis test was used to investigate differences in maximum total point motion between implant groups. An analysis of variance was used to test for differences in translations and rotations between groups. Fishers exact test was used to investigate differences in proportions of implants found to be at risk between groups.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 55 - 55
1 Sep 2012
Wilson DA Dunbar MJ Fong J Glazebrook M
Full Access

Purpose

To compare Radiostereometric Analysis (RSA) and subjective outcomes of Total Knee Arthroplasty (TKA) and Total Ankle Arthroplasty (TAA).

Method

Twenty-five patients were recruited to receive TKA (Zimmer, NexGen LPS Trabecular Metal Monoblock) and 20 patients were recruited to receive TAA (DePuy, Mobility). The tibial component of the TKA and the tibial component of the TAA were followed for two years with RSA with exams postoperatively at six, 12 and 24 months. At two years, inducible displacement RSA at the knee and ankle was also performed. RSA outcomes measured were translations in the anterior-posterior, medial-lateral and distal-proximal directions of both implants. SF-36 outcome questionnaires were completed preoperatively and at each RSA follow-up with the outcome being the mental component score (MCS) and physical component score (PCS). Analysis of variance statistical testing was used to compare RSA outcomes and subjective outcomes.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 555 - 555
1 Nov 2011
Gross M Amirault D Hennigar A Dunbar MJ
Full Access

Purpose: To determine if MIS for primary hip replacement surgery increases the risk of long term aseptic loosening as predicted by implant micromotion measured with radiostereometric analysis (RSA).

Method: Ninety patients undergoing primary THA for osteoarthritis (exclusion criteria: post-traumatic arthritis, rheumatoid arthritis, hip dysplasia, previous hip infection) were randomized to undergo THR surgery utilizing the standard direct lateral approach (n=45; 24 male; age=58 yrs; BMI=27) or MIS via a one-incision direct lateral approach using specific instrumentation (n=45; 23 male; age=55; BMI=29). Uncemented acetabular and femoral (ProfemurZ) components were used with ceramic on ceramic bearings. The femur was marked with 9 tantalum beads placed in the greater trochanter, lesser trochanter, and femoral shaft distal to the tip of the prosthesis. Post-operative care was be standardized according to the care maps at our institution. Primary outcome measure was femoral stem MTPM (maximum total point motion) measured using Model-based RSA. Stereo supine X-rays were taken before weight bearing and 3, 6, and 12 months postoperatively. At the same time intervals Harris Hip Score, Oxford-12, WOMAC, and SF36 questionnaires were administered. Rates of infection, dislocation and revision were recorded.

Results: Eleven patients were lost to follow-up (4 due to missing post-op exams; 5 did not have enough beads placed during surgery; 2 were revised due to failure of the ceramic femoral head). There were five long neck fractures at 17–30 months postop that are reported in detail in a related abstract. There were no differences between groups for all outcome measures. Mean MTPM at 12 months was 2.5mm (SD=1.8mm) for the MIS group and 2.6mm (SD=1.2mm) for the standard group.

Conclusion: No difference between groups at one year indicates MIS for uncemented primary THR through a direct lateral approach does not appear to negatively affect stability of the femoral stem. Although promising, these results require confirmation with 2-year RSA data.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 558 - 558
1 Nov 2011
Wilson DA Hubley-Kozey C Dunbar MJ Wilson JLA
Full Access

Purpose: The goal of this study was to investigate if musculoskeletal activation patterns measured with electromyography (EMG) are predictive of migration of total knee replacements (TKR) measured with radiostereometric analysis (RSA).

Method: 37 TKR patients who were part of a larger randomized controlled RSA trial were recruited to this study. Study participants had been randomized to receive the Nexgen LPS Trabecular Metal tibial monoblock component (n = 19), or the cemented NexGen Option Stemmed tibial component (n = 18) (Zimmer, Warsaw IN). Ethics approval was received from the institutional review board. In the week prior to their surgery, the patients went to the dynamics of human motion laboratory and underwent EMG data collection. Surface electrodes were placed over the vastus lateralis, vastus medialis, rectus femoris, the lateral and medial hamstrings, and the lateral and medial gastrocnemius using standardized placements (Hubley-Kozey et al., 2006). The variability in subject EMG patterns was captured with a set of discrete scores that represented weightings on objectively-extracted features of the gait waveform data using principal component analysis (PCA). Within four days of surgery and at six months post-operatively, patients had bi-planar knee x-rays taken. RSA analysis was performed with MB-RSA (MEDIS, Leiden). RSA results were reported as maximum total point motion (MTPM), and six degrees of freedom translations and rotations at six months.

Results: A correlation was found between the third principle component of the lateral gastrocnemius muscle (representing high gastrocnemius activation in late stance) and the anterior migration of the component (R2=0.247 P=0.002). A correlation was found between the vastus medialis principle component three (representing low vastus medialis activation in late stance) and the anterior migration of the component (R2= 0.338, P=0.000). A stepwise regression model was developed for anterior migration of the tibial component. To reduce the number of terms in the model only the two EMG variables that were correlated with anterior migration, implant type and BMI were entered leaving four possible terms. The stepwise regression eliminated all variables but the lateral gastrocnemius and the vastus medialis. The regression equation was Anterior-Posterior Migration = 0.01 +0.12*Vastus Medialis PC3 + 0.074*Lateral Gastrocnemius PC3 (R2=0.487, R2 Adj=0.457, P< 0.0001)

Conclusion: It has previously been shown that anterior shear on the tibial component of TKR is temporally localized to the last third of stance phase of gait. Both the gastrocnemius and vastus muscle groups have the ability to produce large anterior posterior shear on an the knee during late stance. This result shows that variables which capture the temporal activation patterns of these muscles preoperatively are related to the migration of the tibial component of TKR postoperatively. This may have implications for rehabilitation of these patients.