Introduction. Cementless TKA offers the potential for strong fixation through biologic fixation technology as compared to cemented TKA where fixation is achieved through mechanical integration of the cement. Few mid-term results are available for newer cementless TKA designs that have used additive manufacturing (3-D printing) for component design. The purpose of this study is to present minimum 5-year clinical outcomes and implant survivorship of a specific cementless TKA using a novel 3-D printed
Purpose. Total knee replacement is the one of the most performed surgeries. However, patient's satisfaction rate is around 70–90 % only. The sacrifice of cruciate ligament might be the main reason, especially in young and active patients. ACL stabilizes the knee by countering the anterior displacing and pivoting force, absorbs the shock and provides proprioception of the knee. However, CR knees has been plagued by injury of PCL during the surgery and preservation of the ACL is a demanding technique. Stiffness is more common comparing to PS designed knee. To insert a
A pain free motion of the patella after total knee arthroplasty (TKA) is still a challenge for surgeons and TKA-designers today. After TKA, the restricted guidance of the patella and kinematic alterations of the femorotibial joint results in increased retropatellar pressure and unphysiological patellar tracking. The alignment of the prosthetic components can influence patellofemoral stresses and tracking of the patella. The aim of this study was to demonstrate the consequences of different alignments of the
Introduction. Model-based radiostereometric analysis (MBRSA) allows the in vivo measurement of implant loosening (i.e. migration) from a host bone by acquiring a pair of biplanar radiographs of the patient's implant over time. Focusing on total knee replacement patients, the accuracy of MBRSA in calculating
Introduction. The use of cementless TKA's has been gradually increasing over the past several years given the increasing life expectancy of our patient population. Cementless TKA's have not been rapidly adopted due to the challenges and uncertainty of tibial fixation especially in elderly patients. With the advent of new technologies, the results of cementless TKA's with the potential for long term biologic fixation may now be equivalent or better than cemented TKA's. A highly porous
Instrumented joint prostheses offer the possibility of measuring in vivo loads during activities of daily living. To analyze the complex kinetic situation in the knee joint, a six degree-of-freedom measurement is essential. A tray-in-a-tray
Adequate fixation of implant components is an important goal for all arthroplasty procedures. Aseptic loosening is one of the leading causes of revision surgery in total knee arthroplasty. Radiostereometric analysis (RSA) is an imaging technique to measure implant migration, with established migration thresholds for well-fixed, at risk, and unacceptably migrating components. The purpose of the present study was to examine the long-term fixation of a cemented titanium fixed bearing polished
INTRODUCTION. Total knee arthroplasty (TKA) is typically performed using cement to secure the prosthesis to bone. There are complications associated with cementing that include intra-operative hypotension, third-body abrasive wear, and loosening at the cement interfaces. A cementless prosthesis using a novel keeled trabecular metal
Nowadays, initial fixation and relative movements of the
Introduction. In total knee arthroplasty (TKA), non-cemented implants rely on initial fixation to stabilize the implant in order to facilitate biologic fixation. The initial fixation can be affected by several different factors from type of implant surface, implant design, patient factors, and surgical technique. The initial fixation is traditionally quantified by measuring the motion between the implant and underlying bone during loading (micromotion). Extraction force has also been quantified for cementless devices. The question remains does an increase or decrease in extraction force affect micromotion based on the fact that most loading at the knee joint is in compression. The objective of this research is to investigate if there is any correlation between extraction force and implant micromotion. Methods. The relationship between extraction force and micromotion was evaluated by performing a series of experiments using a synthetic bone analog and a
Introduction. The Rotational alignment is an important factor for survival total knee Arthroplasty. Rotational malalignment causes knee pain, global instability, and wear of the polyethylene inlay. Also, the anterior cortex line was reported that more reliable and more easily identifiable landmark for correct tibial component alignment. The aims of the current study is to identify effect of inserting the
The purpose of the study was to undertake a radiological and clinical comparison of uncemented tibial base-plate fixation with porous or hydroxyapatite coating. Knees were examined radiologically according to Knee Society Guidelines with image intensifier screening and spot films to highlight the bone prosthesis interface. Clinical assessment was performed using the Knee Society Clinical Rating. Hydroxyapatite components were found to have significantly less radiolucent lines than porous coated. Seventy three percent of hydroxyapatite baseplates versus 28% of porous coated baseplates showed no radiolucent lines. All lucent lines in both groups appeared stable with a sclerotic margin and did not appear to be progressive or associated with component loosening. No knees showed any radiolucent lines around the stem in either group. Clinical assessment showed no significant difference between hydroxyapatite and porous coated components. If cementless fixation is to be utilised on the tibial side in knee replacement advantage should be taken of hydroxyapatite augmentation of the component.
Introduction. Beneath infection, instability and malalignment, aseptic tibial component loosening remains a major cause of failure in total knee arthroplasty (TKA) [1]. This emphasizes the need for stable primary and long-term secondary fixation of
Aims. The mean age of patients undergoing total knee arthroplasty (TKA) has reduced with time. Younger patients have increased expectations following TKA. Aseptic loosening of the tibial component is the most common cause of failure of TKA in the UK. Interest in cementless TKA has re-emerged due to its encouraging results in the younger patient population. We review a large series of tantalum trabecular metal cementless implants in patients who are at the highest risk of revision surgery. Methods. A total of 454 consecutive patients who underwent cementless TKA between August 2004 and December 2021 were reviewed. The mean follow-up was ten years. Plain radiographs were analyzed for radiolucent lines. Patients who underwent revision TKA were recorded, and the cause for revision was determined. Data from the National Joint Registry for England, Wales, Northern Island, the Isle of Man and the States of Guernsey (NJR) were compared with our series. Results. No patients in our series had evidence of radiolucent lines on their latest radiological assessment. Only eight patients out of 454 required revision arthroplasty, and none of these revisions were indicated for aseptic loosening of the
Previous retrieval studies demonstrate increased
Purpose. Previous retrieval studies demonstrate increased
Introduction. A stem extension improves fixation stability of a tibial component. We need caution not to contact the tibial cortex with an offset adaptor. A symmetric tibial stem design often requires the component's re-positioning with negative effects. Therefore, the objective of this study was to validate clinical efficacy of a
Introduction. Varus alignment in total knee replacement (TKR) results in a larger portion of the joint load carried by the medial compartment. [1]. Increased burden on the medial compartment could negatively impact the implant fixation, especially for cementless TKR that requires bone ingrowth. Our aim was to quantify the effect varus alignment on the bone-implant interaction of cementless
Abstract. INTRODUCTION. The most frequent mode of aseptic failure of primary total knee replacements is
Introduction and Aims: Mobile bearings have been introduced in total knee arthroplasty (TKA) as a means to improve kinematics and reduce wear. Another theoretical advantage may be a reduction of the torsional and shear stresses at the baseplate – bone interface, and thereby improving the fixation of the tibial component. The aim of this study was to analyse and compare the fixation of tibial components with fixed or mobile bearings in a prospective randomised study using RSA. Method: Fifty-two consecutive patients (31 women, 21 men, mean age 72) with knee osteoarthrosis underwent primary cemented total knee arthroplasty. Included were patients with arthrosis stage III–V and age over 62. Patients were randomised at operation by opening of sealed envelopes to either Mobile Bearing (MB) or Fixed Bearing (FB). The FB knees received a NexGen TKA with titanium