Advertisement for orthosearch.org.uk
Results 1 - 20 of 3468
Results per page:
Bone & Joint Open
Vol. 3, Issue 9 | Pages 710 - 715
5 Sep 2022
Khan SK Tyas B Shenfine A Jameson SS Inman DS Muller SD Reed MR

Aims. Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented Thompson’s hemiarthroplasties over a ten-year period, recording all accessible patient and implant outcomes. Methods. Patient identifiers for a consecutive cohort treated between 1 January 2003 and 31 December 2011 were linked to radiographs, surgical notes, clinic letters, and mortality data from a national dataset. This allowed charting of their postoperative course, complications, readmissions, returns to theatre, revisions, and deaths. We also identified all postoperative attendances at the Emergency and Outpatient Departments, and recorded any subsequent skeletal injuries. Results. In total, 1,312 Thompson’s hemiarthroplasties were analyzed (mean age at surgery 82.8 years); 125 complications were recorded, necessitating 82 returns to theatre. These included 14 patients undergoing aspiration or manipulation under anaesthesia, 68 reoperations (5.2%) for debridement and implant retention (n = 12), haematoma evacuation (n = 2), open reduction for dislocation (n = 1), fixation of periprosthetic fracture (n = 5), and 48 revised stems (3.7%), for infection (n = 13), dislocation (n = 12), aseptic loosening (n = 9), persistent pain (n = 6), periprosthetic fracture (n = 4), acetabular erosion (n = 3), and metastatic bone disease (n = 1). Their status at ten years is summarized as follows: 1,180 (89.9%) dead without revision, 34 (2.6%) dead having had revision, 84 (6.6%) alive with the stem unrevised, and 14 (1.1%) alive having had revision. Cumulative implant survivorship was 90.3% at ten years; patient survivorship was 7.4%. Conclusion. The Thompson’s stem demonstrates very low rates of complications requiring reoperation and revision, up to ten years after the index procedure. Fewer than one in ten patients live for ten years after fracture. This study supports the use of a cemented Thompson’s implant as a cost-effective option for frail hip fracture patients. Cite this article: Bone Jt Open 2022;3(9):710–715


Bone & Joint Open
Vol. 4, Issue 11 | Pages 839 - 845
6 Nov 2023
Callary SA Sharma DK D’Apollonio TM Campbell DG

Aims. Radiostereometric analysis (RSA) is the most accurate radiological method to measure in vivo wear of highly cross-linked polyethylene (XLPE) acetabular components. We have previously reported very low wear rates for a sequentially irradiated and annealed X3 XLPE liner (Stryker Orthopaedics, USA) when used in conjunction with a 32 mm femoral heads at ten-year follow-up. Only two studies have reported the long-term wear rate of X3 liners used in conjunction with larger heads using plain radiographs which have poor sensitivity. The aim of this study was to measure the ten-year wear of thin X3 XLPE liners against larger 36 or 40 mm articulations with RSA. Methods. We prospectively reviewed 19 patients who underwent primary cementless THA with the XLPE acetabular liner (X3) and a 36 or 40 mm femoral head with a resultant liner thickness of at least 5.8 mm. RSA radiographs at one week, six months, and one, two, five, and ten years postoperatively and femoral head penetration within the acetabular component were measured with UmRSA software. Of the initial 19 patients, 12 were available at the ten-year time point. Results. The median proximal, 2D, and 3D wear rates calculated between one and ten years were all less than 0.005 mm/year, with no patient recording a proximal wear rate of more than 0.021 mm/year. Importantly, there was no increase in the wear rate between five and ten years. Conclusion. The very low wear rate of X3 XLPE liners with larger articulations remains encouraging for the future clinical performance of this material. Cite this article: Bone Jt Open 2023;4(11):839–845


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 52 - 52
4 Apr 2023
García-Rey E Saldaña L
Full Access

Pelvic tilt can vary over time due to aging and the possible appearance of sagittal spine disorders. Cup position in total hip arthroplasty (THA) can be influenced due to these changes. We assessed the evolution of pelvic tilt and cup position after THA and the possible appearance of complications for a minimum follow-up of ten years. 343 patients received a THA between 2006 and 2009. All were diagnosed with primary osteoarthritis and their mean age was 63.3 years (range, 56 to 80). 168 were women and 175 men. 250 had no significant lumbar pathology, 76 had significant lumbar pathology and 16 had lumbar fusion. Radiological analysis included sacro-femoral-pubic (SFP), acetabular abduction (AA) and anteversion cup (AV) angles. Measurements were done pre-operatively and at 6 weeks, and at five and ten years post-operatively. Three measurements were recorded and the mean obtained at all intervals. All radiographs were evaluated by the same author, who was not involved in the surgery. There were nine dislocations: six were solved with closed reduction, and three required cup revision. All the mean angles changed over time; the SFP angle from 59.2º to 60º (p=0.249), the AA angle from 44.5º to 46.8º (p=0.218), and the AV angle from 14.7º to 16.2º (p=0.002). The SFP angle was lower in older patients at all intervals (p<0.001). The SFP angle changed from 63.8 to 60.4º in women and from 59.4º to 59.3º in men, from 58.6º to 59.6º (p=0.012). The SFP angle changed from 62.7º to 60.9º in patients without lumbar pathology, from 58.6º to 57.4º in patients with lumbar pathology, and from 57.0º to 56.4º in patients with a lumbar fusion (p=0.919). The SFP cup angle was higher in patients without lumbar pathology than in the other groups (p<0.001), however, it changed more than in patients with lumbar pathology or fusion at ten years after THA (p=0.04). Posterior pelvic tilt changed with aging, influencing the cup position in patients after a THA. Changes due to lumbar pathology could influence the appearance of complications long-term


Bone & Joint Open
Vol. 5, Issue 9 | Pages 736 - 741
4 Sep 2024
Farr S Mataric T Kroyer B Barik S

Aims. The paediatric trigger thumb is a distinct clinical entity with unique anatomical abnormalities. The aim of this study was to present the long-term outcomes of A1 pulley release in idiopathic paediatric trigger thumbs based on established patient-reported outcome measures. Methods. This study was a cross-sectional, questionnaire-based study conducted at a tertiary care orthopaedic centre. All cases of idiopathic paediatric trigger thumbs which underwent A1 pulley release between 2004 and 2011 and had a minimum follow-up period of ten years were included in the study. The abbreviated version of the Disabilities of Arm, Shoulder and Hand questionnaire (QuickDASH) was administered as an online survey, and ipsi- and contralateral thumb motion was assessed. Results. A total of 67 patients completed the survey, of whom 63 (94%) had full interphalangeal joint extension or hyperextension. Severe metacarpophalangeal joint hyperextension (> 40°) was documented in 15 cases (22%). The median QuickDASH score was 0 (0 to 61), indicating excellent function at a median follow-up of 15 years (10 to 19). Overall satisfaction was high, with 56 patients (84%) reporting the maximal satisfaction score of 5. Among 37 patients who underwent surgery at age ≤ two years, 34 (92%) reported the largest satisfaction, whereas this was the case for 22 of 30 patients (73%) with surgery at aged > two years (p = 0.053). Notta’s nodule resolved in 49 patients (73%) at final follow-up. No residual triggering or revision surgery was observed. Conclusion. Surgical release of A1 pulley in paediatric trigger thumb is an acceptable procedure with excellent functional long-term outcomes. There was a trend towards higher satisfaction with earlier surgery among the patients. Cite this article: Bone Jt Open 2024;5(9):736–741


Bone & Joint Open
Vol. 1, Issue 12 | Pages 743 - 748
1 Dec 2020
Mahon J McCarthy CJ Sheridan GA Cashman JP O'Byrne JM Kenny P

Aims. The Exeter V40 cemented femoral stem was first introduced in 2000. The largest single-centre analysis of this implant to date was published in 2018 by Westerman et al. Excellent results were reported at a minimum of ten years for the first 540 cases performed at the designer centre in the Exeter NHS Trust, with stem survivorship of 96.8%. The aim of this current study is to report long-term outcomes and survivorship for the Exeter V40 stem in a non-designer centre. Methods. All patients undergoing primary total hip arthroplasty using the Exeter V40 femoral stem between 1 January 2005 and 31 January 2010 were eligible for inclusion. Data were collected prospectively, with routine follow-up at six to 12 months, two years, five years, and ten years. Functional outcomes were assessed using Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores. Outcome measures included data on all components in situ beyond ten years, death occurring within ten years with components in situ, and all-cause revision surgery. Results. A total of 829 stems in 745 patients were included in the dataset; 155 patients (20.8%) died within ten years, and of the remaining 664 stems, 648 stems (97.6%) remained in situ beyond ten years. For the 21 patients (2.5%) undergoing revision surgery, 16 femoral stems (1.9%) were revised and 18 acetabular components (2.2%) were revised. Indications for revision in order of decreasing frequency were infection (n = 6), pain (n = 6), aseptic component loosening (n = 3), periprosthetic fracture (n = 3), recurrent dislocation (n = 2), and noise production (ceramic-on-ceramic squeak) (n = 1). One patient was revised for aseptic stem loosening. The mean preoperative WOMAC score was 61 (SD 15.9) with a mean postoperative score of 20.4 (SD 19.3) (n = 732; 88.3%). Conclusion. The Exeter V40 cemented femoral stem demonstrates excellent functional outcomes and survival when used in a high volume non-designer centre. Outcomes are comparable to those of its serially validated predecessor, the Exeter Universal stem. Cite this article: Bone Jt Open 2020;1-12:743–748


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 18 - 18
1 Apr 2022
Kayani B Baawa J Fontalis A Tahmassebi J Wardle N Middleton R Hutchinson J Haddad FS
Full Access

This study reports the ten-year polyethylene liner wear rates, incidence of osteolysis, clinical outcomes and complications of a three-arm, multicentre randomised controlled trial comparing Cobalt-Chrome (CoCr) and Oxidised Zirconium (OxZr) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) versus highly cross-linked polyethylene (XLPE) liners in total hip arthroplasty (THA). Patients undergoing THA from four institutions were prospectively randomised into three groups. Group A received a CoCr femoral head and XLPE liner; Group B received an OxZr femoral head and XLPE liner; and Group C received an OxZr femoral head and UHMWPE liner. Blinded observers recorded predefined outcomes in 262 study patients at regular intervals for ten years following THA. At ten years follow-up, increased linear wear rates were recorded in group C compared to group A (0.133 ± 0.21 mm/yr vs 0.031 ± 0.07 mm/yr respectively, p<0.001) and group B (0.133 ± 0.21 mm/yr vs 0.022 ± 0.05 mm/yr respectively, p<0.001). Patients in group C were associated with increased risk of osteolysis and aseptic loosening requiring revision surgery compared with group A (7/133 vs 0/133 respectively, p=0.007) and group B (7/133 vs 0/135 respectively, p=0.007). There was a non-significant trend towards increased liner wear rates in group A compared to group B (0.031 ± 0.07 mm/yr vs 0.022 ± 0.05 mm/yr respectively, p=0.128). All three groups were statistically comparable preoperatively and at ten years follow-up when measuring normalised Western Ontario and McMaster Universities Osteoarthritis Index(p=0.410), short-form-36 (p = 0.465 mental, p = 0.713 physical), and pain scale scores (p=0.451). The use of UHMWPE was associated with progressively increased annual liner wear rates after THA. At ten years follow-up, this translated to UHMWPE leading to an increased incidence of osteolysis and aseptic loosening requiring revision THA, compared with XLPE. Femoral heads composed of OxZr were associated with a non-significant trend towards reduced wear rates compared to CoCr, but this did not translate to any differences in osteolysis, functional outcomes, or revision surgery between the two treatments groups


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 15 - 15
1 Nov 2021
Kayani B Bawwa J Tahmassebi J Fontalis A Wardle N Middleton R Shardlow D Hutchinson J Haddad F
Full Access

This study reports the ten-year outcomes of a three-arm, multicentre randomised controlled trial comparing Cobalt-Chrome (CoCr) and Oxidised Zirconium (OxZr) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) versus highly cross-linked polyethylene (XLPE) liners in total hip arthroplasty (THA). Patients undergoing THA from four institutions were prospectively randomised into three groups. Group A received a CoCr femoral head and XLPE liner; Group B received an OxZr femoral head and XLPE liner; and Group C received an OxZr femoral head and UHMWPE liner. The outcomes of 262 study patients were analysed at ten years follow-up. At ten years, increased linear wear rates were recorded in group C compared to group A (0.133 ± 0.21 mm/yr vs 0.031 ± 0.07 mm/yr respectively, p<0.001) and group B (0.133 ± 0.21 mm/yr vs 0.022 ± 0.05 mm/yr respectively, p<0.001). Patients in group C had increased risk of osteolysis and aseptic loosening requiring revision surgery compared with group A (7/133 vs 0/133 respectively, p=0.007) and group B (7/133 vs 0/135 respectively, p=0.007). There was a non- significant trend towards increased liner wear rates in group A compared to group B (0.031 ± 0.07 mm/yr vs 0.022 ± 0.05 mm/yr respectively, p=0.128). All three groups were statistically comparable preoperatively and at ten years follow-up from a clinical score perspective. The use of UHMWPE was associated with progressively increased annual liner wear rates. At ten years follow-up, this translated to an increased incidence of osteolysis and aseptic loosening requiring revision, compared with XLPE. Femoral heads composed of OxZr were associated with a non-significant trend towards reduced wear rates compared to CoCr, but this did not translate to any differences in osteolysis, functional outcomes, or revision surgery between the two treatments groups


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 60 - 60
10 Feb 2023
Daly D Maxwell R
Full Access

The purpose of this study is to assess the long term results of combined ACL reconstruction and unicompartmental knee replacements (UKR). These patients have been selected for this combined operation due to their combination of instability symptoms from an absent ACL and unicompartmental arthritis.

Retrospective review of 44 combined UKR and ACL reconstruction by a single surgeon. Surgeries included both medial and lateral UKR combined with either revision ACL reconstruction or primary ACL reconstruction. Patient reported outcomes were obtained preoperatively, at one year, 5 years and 10 years. Revision rate was followed up over 13 years for a mean of 7.4 years post-surgery.

The average Oxford score at one year was 43 with an average increase from pre-operation to 1 year post operation of 15. For the 7 patients with 10 year follow up average oxford score was 42 at 1 year, 43 at 5 years and 45 at 10 years.

There were 5 reoperations. 2 for revision to total knee arthroplasty and 1 for an exchange of bearing due to wear. The other 2 were the addition of another UKR. For those requiring reoperation the average time was 8 years.

Younger more active patients presenting with ACL deficiency causing instability and unicompartmental arthritis are a difficult group to manage. Combining UKR and ACL reconstruction has scant evidence in regard to long term follow up but is a viable option for this select group. This paper has one of the largest cohorts with a reasonable follow up averaging 7.4 years and a revision rate of 11 percent.

Combined unilateral knee replacements and ACL reconstruction can be a successful operation for patients with ACL rupture causing instability and unicompartmental arthritis.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 19 - 19
1 May 2019
Williams G
Full Access

Glenoid exposure is the name of the game in total shoulder arthroplasty. I can honestly say that it took me more than 5 years but less than 10 to feel confident exposing any glenoid, regardless of the degree of bone deformity and the severity of soft-tissue contracture. This lecture represents the synthesis of my experience exposing some of the most difficult glenoids. The basic principles are performing extensive soft-tissue release, minimizing the anteroposterior dimension of the humerus by osteophyte excision, making an accurate humeral neck cut, having a plethora of glenoid retractors, and knowing where to place them. The ten tips, in reverse order of importance are: 10.) Tilt the table away from operative side—this helps face the surface of the glenoid, especially in cases of posterior wear, toward the surgeon. 9.) Have multiple glenoid retractors—these include a large Darrach, a reverse double-pronged Bankart, one or two blunt Homans, small and large Fukudas. 8.) Remove all humeral osteophytes before attempting to retract the humerus posteriorly to expose the glenoid—this helps to decrease the overall anteroposterior dimension of the humerus and allows for maximum posterior displacement of the humerus. 7.) Make an accurate humeral neck cut—even 5mm of extra humeral bone will make glenoid exposure difficult. 6.) Optimal humeral position—it has been taught that abduction, external rotation, and extension is the optimal position. It may vary with each case. Therefore, experiment with humeral rotation to find the position that allows maximum visualization. This is often the position that makes the cut surface of the humerus parallel to the surface of the glenoid. 5.) Optimal retractor placement—my typical retractor placement is a Fukuda on the posterior lip of the glenoid, a reverse double-pronged Bankart on the anterior neck of the scapula, and a blunt Homan posterosuperiorly. Occasionally, a second blunt Homan anteroinferiorly is helpful, particularly in muscular males with a large pectoralis major. 4.) Laminar spreader for lateral humeral displacement—this can be helpful for posterior capsulorrhaphy or for posterior glenoid bone grafting. 3.) Maximal humeral capsular release—the release of the anterior capsule from the humerus must go well past the 6 o'clock position and up the posterior surface of the humerus. This aides in humeral exposure but also allows for more posterior displacement of the humerus during glenoid exposure. 2.) Anteroinferior capsular release or excision—extensive anteroinferior release or excision (my preference), allows for maximal posterior humeral displacement and also restores external rotation. 1.) Posterior or posteroinferior capsular release—release of the posteroinferior corner of the capsule from the glenoid results in a noticeable increase in posterior humeral retractability. In cases without substantial posterior subluxation, extensive release of the entire posterior capsule is performed


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 55 - 55
1 Dec 2016
Lanting B Thoren J Yuan X McCalden R McAuley J MacDonald S Vasarhelyi E Howard J Naudie D Teeter M
Full Access

Adequate fixation of implant components is an important goal for all arthroplasty procedures. Aseptic loosening is one of the leading causes of revision surgery in total knee arthroplasty. Radiostereometric analysis (RSA) is an imaging technique to measure implant migration, with established migration thresholds for well-fixed, at risk, and unacceptably migrating components. The purpose of the present study was to examine the long-term fixation of a cemented titanium fixed bearing polished tibial baseplate. Patients enrolled in a previous two-year prospective trial were recalled at ten years. All patients received a cemented, posterior-stabilised total knee replacement of the same design implanted by one of three surgeons. Of the original 35 patients, 16 were available for long-term follow-up, with one patient lost to follow-up, nine patients deceased, and a further nine patients unwilling to return to the clinic. Each patient underwent RSA imaging in a supine position using a conventional RSA protocol. Migration of the tibial component in all planes as well as maximum total point motion (MTPM) was compared between all time points (baseline, six weeks, three months, six months, one year, two years) up to the ten year follow-up visits. Outcome scores including the Knee Society Score (KSS), WOMAC, SF-12, and UCLA Activity Score were recorded. At ten years, the mean migrations of the tibial component were less than 0.1 mm and 0.1 degree in all planes relative to the post-operative RSA exam. There was no significant difference in tibial component migration between time points. However, MTPM increased significantly over time (p = 0.002), from 0.23 ± 0.18 mm at six weeks to 0.42 ± 0.20 mm at ten years. At one year, 13 patients had an acceptable MTPM level, three patients had an ‘at risk’ level, and no patient had an ‘unacceptable’ level. No patients were revised at ten years. WOMAC and KSS were significantly improved (p < 0.0001) at the latest follow-up compared to pre-operatively, but there was no difference in SF-12. The median UCLA Activity Score at latest follow-up was six (range, two to eight). The tibial baseplate demonstrated solid fixation at ten years. No patients had an unacceptable MTPM level at one year and no patients were revised at ten years, supporting the use of RSA to predict long-term loosening risk. The low level of tibial baseplate migration found in the present study correlates to the low rate of revision for this implant as reported in individual studies and in joint replacement registries


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 12 - 12
7 Aug 2023
Osmani H Nicolaou N Anand S Metcalfe A McDonnell S
Full Access

Abstract

Introduction

The knee is the most commonly injured joint in sporting accidents. They cause substantial disability, time off work and long-term problems. There remains a limited number of high-quality randomised controlled trials assessing first time, acute soft tissue knee injuries. Key areas requiring answers include prevention, diagnosis, treatment, rehabilitation and delivery of care. In association with the James Lind Alliance, this BASK, BOSTAA and BOA supported prioritising exercise was undertaken over a year.

Methodology

The James Lind Alliance methodology was followed. An initial survey invited patients and healthcare professionals to submit their uncertainties regarding soft tissue knee injury prevention, diagnosis, treatment, rehabilitation and delivery of care. Over 1000 questions were submitted. Seventy-four questions were formulated to encompass common concerns. These were checked against best available evidence. Following the interim survey, 27 questions were taken forward to the final workshop in January 2023, where they were discussed, ranked and scored in multiple rounds of prioritisation by groups of healthcare professionals, patients and carers.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 65 - 65
1 Feb 2020
Garcia-Rey E Garcia-Cimbrelo E
Full Access

Introduction. Pelvic tilt can vary over time due to aging and the possible appearance of sagittal spine disorders. Cup position in total hip arthroplasty (THA) can be influenced due to these changes. We assessed the evolution of pelvic tilt and cup position after THA and the possible appearance of complications for a minimum follow-up of ten years. Materials and methods. 343 patients received a cementless THA between 2006 and 2009. All were diagnosed with primary osteoarthritis and their mean age was 63.3 years (range, 56 to 80). 168 were women and 175 men. 250 had no significant lumbar pathology, 76 had significant lumbar pathology and 16 had lumbar fusion. Radiological analysis included sacro-femoral-pubic (SFP), acetabular abduction (AA) and anteversion cup (AV) angles. Measurements were done pre-operatively and at 6 weeks, and at five and ten years post-operatively. Three measurements were recorded and the mean obtained at all intervals. All radiographs were evaluated by the same author, who was not involved in the surgery. Results. There were nine dislocations: six were solved with closed reduction, and three required cup revision. All the mean angles changed over time; the SFP angle from 59.2º to 60º (p=0.249), the AA angle from 44.5º to 46.8º (p=0.218), and the AV angle from 14.7º to 16.2º (p=0.002). The SFP angle was lower in older patients at all intervals (p<0.001). The SFP angle changed from 63.8 to 60.4º in women and from 59.4º to 59.3º in men, from 58.6º to 59.6º (p=0.012). The SFP angle changed from 62.7º to 60.9º in patients without lumbar pathology, from 58.6º to 57.4º in patients with lumbar pathology, and from 57.0º to 56.4º in patients with a lumbar fusion (p=0.919). The SFP cup angle was higher in patients without lumbar pathology than in the other groups (p<0.001), however, it changed more than in patients with lumbar pathology or fusion at ten years after THA (p=0.04). Conclusions. Posterior pelvic tilt changed with aging, influencing the cup position in patients after a THA. Changes due to lumbar pathology could influence the appearance of complications at mid and long-term


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 304 - 304
1 Jul 2011
Field R Eswaramoorthy V Rushton N Biant L
Full Access

Aims: Minimum ten year clinical, radiological and postmortem results of the flexible Cambridge Cup. This acetabular prosthesis was designed to replace the horseshoe shaped articular cartilage and provide physiological loading with minimal resection of healthy bone. Method: Fifty female patients aged over 70 years with a displaced intra-capsular fracture of the femoral neck were recruited to the ethically-approved prospective study. They underwent implantation of the Cambridge Cup, which has an outer polybutyleneterephthalate shell and an inner UHMWPE bearing, with a Thompson-type hemiarthroplasty. The cups were manufactured with a 60μm plasma-sprayed coating of hydroxyapatite. This was removed from half the cups to simulate the effects of long-term HA resorption. Implants were sterilised by gamma irradiation in air. Independent clinical and radiological assessments were undertaken before discharge, at 6 weeks, one year, 18 months, two -, five-, seven- and ten years. Patients were scored using the Barthel Index, the Charnley-modified Merle d’Aubigne scores and latterly the Oxford hip score. The date and cause of death were obtained from hospital records and death certificates. Fifteen Cambridge Cups were retrieved post-mortem for histological and wear analysis. Results: The mean functional scores recovered to levels before fracture. These scores decreased with advancing age at five years. The mortality rates were 16%, 28%, 46% and 92% at 1, 2, 5 and 10 years. The Oxford hip scores in patients surviving between five and ten years were maintained. The HA coated implants remained asymptomatic. Three uncoated components required revision for migration. No evidence of accelerated UHMWPE wear was seen on retrievals or radiographs. Histological analysis of the retrieved HA coated specimens showed excellent bony fixation, uncoated cups showed predominantly fibrous tissue. Conclusion: The uncemented Cambridge Cup was implanted in a challenging environment of osteoporotic bone. Clinical, radiographic and post-mortem results up to ten years are excellent


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_6 | Pages 7 - 7
1 Jun 2022
Sheridan M Mclean M Madeley N Kumar CS
Full Access

Arthrodesis of the 1st metatarsophalangeal joint (MTPJ) is a common procedure used for the treatment of end stage arthritis. We studied a cohort of patients who underwent an isolated 1st MTPJ Fusion for the treatment of hallux rigidus. Here we report the 10-year clinical outcomes, complication rate, requirement for further surgery and patient experience.

All patients, who underwent an isolated 1st MTPJ Fusion for osteoarthritis from June 2008 until November 2011 were included. Demographics, clinical outcome data and subsequent procedures performed were collected from a departmental database (Bluespier). Patients were contacted and asked to complete the MOxFQ questionnaire and rate their satisfaction using pain, function and if they would undergo the surgery again. Mean follow up was 10.85 (range 9–12) years.

A total of 161 patients (183 feet) underwent an isolated 1st MTPJ fusion during this time period. 156 of the feet showed a successful arthrodesis (85.2% fusion rate); 27 patients required revision surgery, 19 (10.4%) for a symptomatic non-union and 8 (4.4%) for mal-union. Those patients with co-morbidities (diabetes and gout) required revision earlier than those without (p<0.01). Average MOxFQ score was 16.6 (0–64) and 28 out of the 38 (73.6%) said they would have the operation again.

Overall, the long-term results of the 1st MTPJ fusion had good outcomes with a successful fusion rate and minimal complications, both in line with the corresponding literature. In this series, fusion provided high patient satisfaction with the majority of patients opting to undergo fusion with the gift of hindsight.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 19 - 19
1 Nov 2015
Middleton R Findlay I Onafowokan O Parmar D Bartlett G Fern E Norton M
Full Access

Introduction. Open hip debridement surgery has been used for treatment of femoral acetabular impingement pain for over ten years in our unit. While literature has reported promising short term outcomes, longer term outcomes are more sparsely reported. We aim to assess survivorship and functional outcome at ten years, in patients who have undergone open hip debridement. Patients/Materials & Methods. All patients who had undergone open debridement surgery were identified on our database. The electronic, radiographic and paper records were reviewed. Demographic data, radiological and operative findings were recorded. All patients underwent ten year review with a standardised AP hips radiograph, questionnaire, non-arthritic hip score (NAHS), oxford hip score (OHS) and SF12 score. Results. A total of 1626 operations were identified of which 37 had reached the tenth anniversary of their surgery. There were 14 females and 22 males. The average age was 41. 10 (45%) had undergone subsequent hip arthroplasty. Those who underwent hip arthroplasty were older at initial surgery than those who survived. However, this was not statistically significant (p= 0.127). Those who failed had a higher Tonnis and UCLA grade at time of surgery. The majority failed within the first 2 years. In those whose hip survived, the average NAHS was 87. 100% of survivors deemed there surgery to have been worthwhile. Discussion. These results represent the first cohort of our patients to reach ten year follow up. The results represent a learning curve in patient selection. It is unsurprising that those with more arthritic change were more likely to fail. Conclusion. In patients with clearly defined CAM impingement without joint space narrowing, open hip debridement remains an operation with worthwhile outcomes at ten years


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 121 - 122
1 Mar 2008
MacDonald S Marr J Bourne R Rorabeck C
Full Access

The Self Aligning (SAL I) total knee prosthesis (Sulzer, Winterthur) is a first generation cruciate retaining mobile bearing implant allowing unrestricted rotation and up to 5 mm. of translation. A consecutive series of two hundred and three SAL I components in one hundred and sixty- seven patients were implanted between 1990 and 1994 and were reviewed clinically and radiographically. Quality of life outcomes (SF-12 and WOMAC) were also reviewed pre-operatively and regular intervals. This first generation mobile bearing knee implant in this series, continues to function well at a minimum ten years follow-up, with a mechanical failure rate (8%) comparable to fixed bearing designs. A consecutive series of SAL I total knee arthroplasties were performed between 1990 and 1994 and were reviewed clinically, radiographically and with standardized quality of life outcome tools, including the SF-12 and the Western Ontario MacMaster Osteoarthritis Index (WOMAC). Patient demographics, radiographs, and multiple validated outcome measures (WOMAC, SF12, Knee Society Clinical Rating System) were evaluated pre-operatively, at three, twelve, and twenty-four months and every two years thereafter. The series included two hundred and three SAL I implants in one hundred and sixy-sevenpatients. There have been sixty-nine patient deaths (eighty-five procedures), nine patients (eleven procedures) now reside in nursing homes and are unable to return due to medical complications, two patients (three procedures) could not be located. Nine-teen patients/procedures have had revision surgery. Therefore, seventy-six patients (ninety-three procedures) were evaluated with over ten year follow-up (average 10.89 years, range 10.03–13.72). Indications for revision included, sepsis (three), aseptic loosening (eight), instability (two) and poly-wear (six). The KSCRS was assessed for all remaining patients at greater than ten years including pain (45.83), function(65.60), range of motion extension(0.13) and flexion(113.82) as well as the results of the WOMAC (pain-4.36, joint stiffness-2.29, function-18.66, total- 15.92) and SF-12 (Mental-55.37 Physical- 34.99). The SAL I mobile bearing implant continues to perform comparably to fixed bearing cruciate retaining designs. This first generation mobile bearing knee implant continues to function well at a minimum ten years follow-up, with a mechanical failure rate (8%) comparable to fixed bearing designs


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 40 - 40
1 Dec 2017
Fischbacher A Borens O
Full Access

Aim. There is a constant increase of joint arthroplasties to improve the quality of life of an aging population. Prosthetic-joint infections are rare, with an incidence of 1–2%, but they represent serious complications in terms of morbidity and mortality. The mortality was known to be approaching 8% in the elderly. The aim of this retrospective study is to reassess the two-year mortality rate over the last ten years. Method. Patients having a prosthetic joint infection at Lausanne University Hospital (Switzerland) between 2006 and 2016 were included. The two-year mortality rate depending on sex, age, type of infection and type of surgical therapy was measured. Results. 444 patients (61% hips, 37% knees) were identified with a median age of 70 years. The two-year mortality rate was 5%. There was no difference between hip and knee prosthesis but the mortality was higher for men (6%) than women (4%). The rate has not changed over the last ten years. However, the mortality rate is more than doubling (12%) for patients over eighty years old. Furthermore, chronic prosthetic-joint infections seem to have a higher mortality rate (7%) than acute ones (4%). Finally, patients treated with a one-stage or two-stage exchange seem to have a lower mortality rate (<1%) than the ones treated with debridement and retention (11%). Conclusion. The mortality seems to be less than thought before and depends on sex, age, type of infection and type of surgical therapy


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 143 - 143
1 Nov 2021
McCarthy C Mahon J Sheridan G Welch-Phillips A O'Byrne J Kenny P
Full Access

Introduction and Objective

Ceramic on Ceramic bearings in Total Hip Arthroplasty (THA) afford a low friction coefficient, low wear rates and extreme hardness. Significant complications include hip squeak, ceramic fracture and poor polyethylene performance in revision procedures due to imbedding of abrasive microscopic ceramic fragments. We report on the results of this bearing at a minimum of 10 years.

Materials and Methods

A single-centre retrospective review of 449 THAs was performed. Primary outcome measures included aseptic revision and all-cause revision rates at a minimum of 10 years post operatively. Evaluation of functionality was performed with WOMAC and SF-36 scores which were performed pre-operatively and at intervals of 6 months, one year, 2 years, 5 years and 10 years post operatively.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 58 - 58
1 Oct 2018
Dalury D Chapman DM
Full Access

Introduction. The causes of revision total knee replacement are varied. There is a subset of these revision cases (poly wear and some cases of instability for example) where the ability to retain the metal femoral and tibial components and replacing just the polyethylene is an appealing option. We report on a series of RTKR where only the poly insert was replaced and the patients were followed for a minimum of ten years. Materials and Methods. Our study group consisted of 64 consecutive non infected RTKR patients who underwent a revision of the polyethylene alone between 1998 and 2006. All patients had been treated originally with the same cemented, CR, patella resurfaced primary TKR. Reasons for revision were 51 poly wear and/or osteolysis, 7 instability, and 6 other. The average time from the primary to the revision surgery was 9.1 years (range 2.2 to 16.1 years). All patients had an isolated poly liner change. No femurs or tibial trays were revised. Average age of the cohort at revision was 72.2 (range 48 to 88). Average BMI was 31.9 (range 23.6 to 43.9). There were 36 female patients. Of the group, 42 were ASA 1 or 2 and 22 were ASA 3. Pre-op alignment averaged 6.0 (range 2 varus to 8 valgus). Patients were followed for a minimum of 10 years (range 10 to 19 years). Results. At final follow up 13 patients had died, none were lost to follow up leaving 51 patients available for review. There were 7 reoperations in 6 patients (7 knees). Reasons for reoperation were: 4 aseptic tibial loosening at an average of 4.1 years (range 1.2 to 8.3) following first poly revision, two for polywear at an average 9 years post first poly revision, and one for deep infection (5.6 years post first poly revision). Knee society scores at 6 weeks post revision was 93.5 (range 38 to 100) and at final follow up for the non-revised knees was 91.6 (range 36 to 100). Conclusion. In appropriate settings, where the femoral and tibial components are satisfactorily aligned and well fixed and the soft tissues can be balanced, a poly change alone can provide a durable solution for the revision total knee patient. The ability to retain the metal components has advantages in terms of patient morbidity and cost


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 19 - 19
1 Aug 2017
Williams G
Full Access

Glenoid exposure is the name of the game in total shoulder arthroplasty. I can honestly say that it took me more than 5 years but less than 10 to feel confident exposing any glenoid, regardless of the degree of bone deformity and the severity of soft-tissue contracture. This lecture represents the synthesis of my experience exposing some of the most difficult glenoids. The basic principles are performing extensive soft-tissue release, minimizing the anteroposterior dimension of the humerus by osteophyte excision, making an accurate humeral neck cut, having a plethora of glenoid retractors, and knowing where to place them. The ten tips, in reverse order of importance are: 10.) Tilt the table away from operative side—this helps face the surface of the glenoid, especially in cases of posterior wear, toward the surgeon. 9.) Have multiple glenoid retractors—these include a large Darrach, a reverse double-pronged Bankart, one or two blunt Homans, small and large Fukudas. 8.) Remove all humeral osteophytes before attempting to retract the humerus posteriorly to expose the glenoid—this helps to decrease the overall anteroposterior dimension of the humerus and allows for maximum posterior displacement of the humerus. 7.) Make an accurate humeral neck cut—even 5mm of extra humeral bone will make glenoid exposure difficult. 6.) Optimal humeral position—it has been taught that abduction, external rotation, and extension is the optimal position. It may vary with each case. Therefore, experiment with humeral rotation to find the position that allows maximum visualization. This is often the position that makes the cut surface of the humerus parallel to the surface of the glenoid. 5.) Optimal retractor placement—my typical retractor placement is a Fukuda on the posterior lip of the glenoid, a reverse double-pronged Bankart on the anterior neck of the scapula, and a blunt Homan posterosuperiorly. Occasionally, a second blunt Homan anteroinferiorly is helpful, particularly in muscular males with a large pectoralis major. 4.) Laminar spreader for lateral humeral displacement—this can be helpful for posterior capsulorrhaphy or for posterior glenoid bone grafting. 3.) Maximal humeral capsular release—the release of the anterior capsule from the humerus must go well past the 6 o'clock position and up the posterior surface of the humerus. This aides in humeral exposure but also allows for more posterior displacement of the humerus during glenoid exposure. 2.) Anteroinferior capsular release or excision—extensive anteroinferior release or excision (my preference), allows for maximal posterior humeral displacement and also restores external rotation. 1.) Posterior or posteroinferior capsular release—release of the posteroinferior corner of the capsule from the glenoid results in a noticeable increase in posterior humeral retractability. In cases without substantial posterior subluxation, extensive release of the entire posterior capsule is performed. Following these steps will help the surgeon to gain adequate glenoid exposure, even in the most difficult cases