Aims. Radiological residual acetabular dysplasia (RAD) has been reported in up to 30% of children who had successful brace treatment of infant developmental dysplasia of the hip (DDH). Predicting those who will resolve and those who may need corrective surgery is important to optimize follow-up protocols. In this study we have aimed to identify the prevalence and predictors of RAD at two years and five years post-bracing. Methods. This was a single-centre, prospective longitudinal cohort study of infants with DDH managed using a published, standardized Pavlik harness protocol between January 2012 and December 2016. RAD was measured at two years’ mean follow-up using acetabular index-lateral edge (AI-L) and acetabular index-sourcil (AI-S), and at five years using AI-L, AI-S, centre-edge angle (CEA), and acetabular depth ratio (ADR). Each hip was classified based on published normative values for normal, borderline (1 to 2
The purpose of this study was to assess the reliability and responsiveness to hip surgery of a four-point modified Care and Comfort Hypertonicity Questionnaire (mCCHQ) scoring tool in children with cerebral palsy (CP) in Gross Motor Function Classification System (GMFCS) levels IV and V. This was a population-based cohort study in children with CP from a national surveillance programme. Reliability was assessed from 20 caregivers who completed the mCCHQ questionnaire on two occasions three weeks apart. Test-retest reliability of the mCCHQ was calculated, and responsiveness before and after surgery for a displaced hip was evaluated in a cohort of children.Aims
Methods
The surgical helmet system (SHS) was developed to reduce the risk of periprosthetic joint infection (PJI), but the evidence is contradictory, with some studies suggesting an increased risk of PJI due to potential leakage through the glove-gown interface (GGI) caused by its positive pressure. We assumed that SHS and glove exchange had an impact on the leakage via GGI. There were 404 arthroplasty simulations with fluorescent gel, in which SHS was used (H+) or not (H-), and GGI was sealed (S+) or not (S-), divided into four groups: H+S+, H+S-, H-S+, and H-S-, varying by exposure duration (15 to 60 minutes) and frequency of glove exchanges (0 to 6 times). The intensity of fluorescent leakage through GGI was quantified automatically with an image analysis software. The effect of the above factors on fluorescent leakage via GGI were compared and analyzed.Aims
Methods
Open lower limb fracture is life-changing, resulting in substantial morbidity and resource demand, while inconsistent outcome-reporting hampers systematic review and meta-analysis. A core outcome set establishes consensus among key stakeholders for the recommendation of a minimum set of outcomes. This study aims to define a core outcome set for adult open lower limb fracture. Candidate outcomes were identified from a previously published systematic review and a secondary thematic analysis of 25 patient interviews exploring the lived experience of recovery from open lower limb fracture. Outcomes were categorized and sequentially refined using healthcare professional and patient structured discussion groups. Consensus methods included a multi-stakeholder two-round online Delphi survey and a consensus meeting attended by a purposive sample of stakeholders, facilitated discussion, and voting using a nominal group technique.Aims
Methods
This study aimed to evaluate the accuracy of implant placement with robotic-arm assisted total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). The study analyzed a consecutive series of 69 patients who underwent robotic-arm assisted THA between September 2018 and December 2019. Of these, 30 patients had DDH and were classified according to the Crowe type. Acetabular component alignment and 3D positions were measured using pre- and postoperative CT data. The absolute differences of cup alignment and 3D position were compared between DDH and non-DDH patients. Moreover, these differences were analyzed in relation to the severity of DDH. The discrepancy of leg length and combined offset compared with contralateral hip were measured.Aims
Methods
Little guidance exists in the current literature regarding which patient recorded outcome measures (PROMs) are most clinically appropriate following anterior cruciate ligament reconstruction (ACL) surgery, and what results surgeons should expect or accept. Many PROMs have been validated, but their “ideal” results have not been published, limiting a surgeon's ability to compare their patients’ outcomes with those of their colleagues. We undertook a systematic review of PROMs for ACL to look at common usage and outcomes. After appropriate paper selection, we then undertook a pragmatic meta-analysis (i.e., including all papers that fulfilled the selection criteria, regardless of CONSORT status) and calculated weighted mean outcome scores and
Patients may be able to return to higher level activities following hip arthroplasty with modern techniques and prostheses, but the Oxford hip score, the standard PROM used by the NJS exhibits severe skew and kurtosis. The commonest score is 48/48. Most patients score above 40 preventing any discrimination between approaches or prostheses. We therefore sought both subjective and objective metrics which were relevant and valid without skew or high kurtosis in postoperative patients. The Metabolic Equivalent of Task (MET) reports energy usage in kcal/min burnt across a range of activities, condensed into a score of 0–25. A MET over 8 is considered ‘conditioning exercise’ tethered to life expectancy. A 2 point difference in average MET is considered a clinically relevant difference. Walking speed is a simple valid metric tethered to life expectancy, with a 0.1m/sec difference in walking speed equates to a clinically important difference. Oxford Hip Score (OHS), and the MET were prospectively recorded in 221 primary hip arthroplasty procedures pre-operatively and at 1-year using a web based application. Pre and postoperative Gait analysis was undertaken on a subgroup of 34 patients, in comparison with age and sex matched controls. Post-operatively, the OHS demonstrated significant skewed distributions with ceiling effects of 41% scoring 48/48. The MET was normally distributed around a mean of 10.3, with a
Utility score is a preference-based measure of general health state – where 0 is equal to death, and 1 is equal to perfect health. To understand a patient's smallest perceptible change in utility score, the minimal clinically important difference (MCID) can be calculated. However, there are multiple methods to calculate MCID with no consensus about which method is most appropriate. The aim of this study is to calculate MCID values for the Veterans-RAND 12 (VR12) utility score using varying methods. Our hypothesis is that different methods will yield different MCID values. A tertiary institutional registry (SMART) was used as the study cohort. Patients who underwent unilateral TKA for osteoarthritis from January 2012 to January 2020 were included. Utility score was calculated from VR12 responses using the standardised Brazier's method. Distribution and anchor methods were used for the MCID calculation. For distribution methods, 0.5
Successful estimation of postoperative PROMs prior to a joint replacement surgery is important in deciding the best treatment option for a patient. However, estimation of the outcome is associated with substantial noise around individual prediction. Here, we test whether a classifier neural network can be used to simultaneously estimate postoperative PROMs and uncertainty better than current methods. We perform Oxford hip score (OHS) estimation using data collected by the NJR from 249,634 hip replacement surgeries performed from 2009 to 2018. The root mean square error (RMSE) of the various methods are compared to the
Bone age is a radiographical assessment used in pediatric medicine due to its relative objectivity in determining biological maturity compared to chronological age and size.1 Currently, Greulich and Pyle (GP) is one of the most common methods used to determine bone age from hand radiographs.2–4 In recent years, new methods were developed to increase the efficiency in bone age analysis like the shorthand bone age (SBA) and the automated artificial intelligence algorithms. The purpose of this study is to evaluate the accuracy and reliability of these two methods and examine if the reduction in analysis time compromises their accuracy. Two hundred thirteen males and 213 females were selected. Each participant had their bone age determined by two separate raters using the GP (M1) and SBA methods (M2). Three weeks later, the two raters repeated the analysis of the radiographs. The raters timed themselves using an online stopwatch while analyzing the radiograph on a computer screen. De-identified radiographs were securely uploaded to an automated algorithm developed by a group of radiologists in Toronto. The gold standard was determined to be the radiology report attached to each radiograph, written by experienced radiologists using GP (M1). For intra-rater variability, intraclass correlation analysis between trial 1 (T1) and trial 2 (T2) for each rater and method was performed. For inter-rater variability, intraclass correlation was performed between rater 1 (R1) and rater 2 (R2) for each method and trial. Intraclass correlation between each method and the gold standard fell within the 0.8–0.9 range, highlighting significant agreement. Most of the comparisons showed a statistically significant difference between the two new methods and the gold standard; however it may not be clinically significant as it ranges between 0.25–0.5 years. A bone age is considered clinically abnormal if it falls outside 2
The functional pelvic tilt when standing and sitting forward of 7402 cases on the OPS, Optimized Ortho, Australia Data Base were reviewed. All patients had undergone lateral radiographs when standing simulating extension of the hip, and sitting forward when the hip is near full flexion. Pelvic tilt was measured as the angle of the Anterior Pelvic Plane to the vertical Sagittal Plane, rotation anteriorly being given a positive value. Pelvises that had rotated more than 13 degrees anteriorly (+ve) when sitting forward or posteriorly (-ve) when standing were considered to place the hip at increased risk of dislocation or edge loading when flexed or extending respectively. This degree of rotation has the effect of changing the acetabular version by approximately10. 0. Most safe zones that have been described have given a range of anteversion of 20. 0. as safe. A change of 10. 0. would potentially place the acetabular orientation outside this range. Further, clinical studies have supported this concept. All lateral radiographs were reviewed to confirm that 281 had undergone instrumented spinal fusion at some level between T12 and S1. There was a large variability in the number and the levels arthrodesed. The range of pelvic mobility in the non-arthrodesed group in extension was −37. 0. to 31. 0. (mean −0.9. 0. ,
Functional outcomes are commonly reported in studies of musculoskeletal oncology patients undergoing limb salvage surgery; however, interpretation requires knowledge of the smallest amount of improvement that is important to patients – the minimally important difference (MID). We established the MIDs for the Musculoskeletal Tumor Society Rating Scale (MSTS) and Toronto Extremity Salvage Score (TESS) in patients with bone tumors undergoing lower limb salvage surgery. This study was a secondary analysis of the recently completed PARITY (Prophylactic Antibiotic Regimens in Tumor Surgery) study. This data was used to calculate: (1) the anchor-based MIDs using an overall function scale and a receiver operating curve analysis, and (2) the distribution-based MIDs based on one-half of the
Successful estimation of postoperative PROMs prior to a joint replacement surgery is important in deciding the best treatment option for a patient. However, estimation of the outcome is associated with substantial noise around individual prediction. Here, we test whether a classifier neural network can be used to simultaneously estimate postoperative PROMs and uncertainty better than current methods. We perform Oxford hip score (OHS) estimation using data collected by the NJR from 249,634 hip replacement surgeries performed from 2009 to 2018. The root mean square error (RMSE) of the various methods are compared to the
Cam-type femoroacetabular impingement is caused by bone excess on the femoral neck abutting the acetabular rim. This can cause cartilage and labral damage due to increased contact pressure as the cam moves into the acetabulum. However, the damage mechanism and the influence of individual mechanical factors (such as sliding distance) are poorly understood. The aim of this study was to identify the cam sliding distance during impingement for different activities in the hip joint. Motion data for 12 different motion activities from 18 subjects, were applied to a hip shape model (selected as most likely to cause damage, anteriorly positioned with a maximum alpha angle of 80°). The model comprised of a pointwise representation of the acetabular rim and points on the femoral head and neck where the shape deviated from a sphere (software:Matlab). The movement of each femoral point was tracked in 3D while an activity motion was applied, and impingement recorded when overlap between a cam point and the acetabular rim occurred. Sliding distance was recorded during impingement for each relevant femoral point. Angular sliding distances varied for different activities. The highest mean (±SD) sliding distance was for leg-crossing (42.62±17.96mm) and lowest the trailing hip in golf swing (2.17±1.11mm). The high
Background. The use of a knotless TightRope for the stabilisation of a syndesmotic injury is a well-recognised mode of fixation. It has been described that the device can be inserted using a “closed” technique. This presents a risk of saphenous nerve entrapment and post-operative pain. Aim. We aimed to establish the actual risk of injury to the Saphenous Nerve using a “closed” technique for the insertion of a TightRope. Method. 20 TightRopes were inserted into Fresh Frozen Cadavers. This was done using the senior authors preferred technique of divergent tightropes with the distal implant directed slightly anterior to the fibula-tibia axis and the proximal implant slightly posterior in order to simulate the greatest risk to the nerve. This was done under image Intensifier guidance to simulate an intraoperative environment. The medial side of the distal tibia was then dissected to directly record and measure the relationship of the TightRope to the Saphenous Nerve. Measurements were taken using digital calipers from the centre of the button on the medial side of the TightRope to the centre of the nerve at the point of closest proximity. Results. 12 TightRopes were found to exit posterior to the nerve, 7 anterior and 1 penetrated through the centre of the nerve. The mean distance from the centre of the button to the nerve was 6.99mm (range 0.72–14.52mm,
In this RCT the primary aim was to assess whether a short (125mm) Exeter V40 stem offered an equivalent hip specific function compared to the standard (150mm) stem when used for cemented total hip arthroplasty (THA). Secondary aims were to evaluate health-related quality of life (HRQoL), patient satisfaction, stem height and alignment, radiographic loosening, and complications between the two stems. A prospective multicentre double-blind randomised control trial was conducted. During a 15-month period, 220 patients undergoing THA were randomised to either a standard (n=110) or short (n=110) stem Exeter. There were no significant (p≥0.065) differences in preoperative variables between the groups. Functional outcomes and radiographic assessment were undertaken at 1- and 2-years. There were no differences (p=0.428) in hip specific function according to the Oxford hip score at 1-year (primary endpoint) or at 2-years (p=0.767) between the groups. The short stem group had greater varus angulation (0.9 degrees, p=0.003) when compared to the standard group and were more likely (odds ratio 2.42, p=0.002) to have varus stem alignment beyond one
Introduction. Recent technological advancements have led to the introduction of robotic-assisted total knee arthroplasty to improve the accuracy and precision of bony resections and implant position. However, the in vivo accuracy is not widely reported. The primary objective of this study is to determine the accuracy and precision of a cut block positioning robotic arm. Method. Seventy-seven patients underwent total knee arthroplasty with various workflows and alignment targets by three arthroplasty-trained surgeons with previous experience using the ROSA® Knee System. Accuracy and precision were determined by measuring the difference between various workflow time points, including the final pre-operative plan, validated resection angle, and post-operative radiographs. The mean difference between the measurements determined accuracy, and the
Abstract. Background. Aim of this study is to determine the difference between re-operation rates after conventional Methods of fixation of patella fractures using Metallic implants and novel technique of all suture fixation using Ethibond or fiber tape. Methods. This is a retrospective comparative analysis involving 62 patients who had a transverse patellar fracture and underwent surgery between January 2013 to December 2021. Selected patients were divided, based on different fixation methods used, into four groups - TBW group, CC screw group, Encirclage group and Suture Fixation Group. Patients were followed till bone union was evident on radiographs. Number of patients in Metallic implant group undergoing repeat operation were compared with the patients who underwent patella fracture fixation using all suture technique. Mean and
INTRODUCTION. Determining proper joint tension in reverse total shoulder arthroplasty (rTSA) can be a challenging task for shoulder surgeons. Often, this is a subjective metric learned by feel during fellowship training with no real quantitative measures of what proper tension encompasses. Tension too high can potentially lead to scapular stress fractures and limitation of range of motion (ROM), whereas tension too low may lead to instability. New technologies that detect joint load intraoperatively create the opportunity to observe rTSA joint reaction forces in a clinical setting for the first time. The purpose of this study was to observe the differences in rTSA loads in cases that utilized two different humeral liner sizes. METHODS. Ten different surgeons performed a total of 37 rTSA cases with the same implant system. During the procedure, each surgeon reconstructed the rTSA implants to his or her own preferred tension. A wireless load sensing humeral liner trial (VERASENSE for Equinoxe, OrthoSensor, Dania Beach, FL) was used in lieu of a traditional plastic humeral liner trial to provide real-time load data to the operating surgeon during the procedure. Two humeral liner trial sizes were offered in 38mm and 42mm curvatures and were selected each case based on surgeon preference. To ensure consistent measurements between surgeons, a standardized ROM assessment consisting of four dynamic maneuvers (maximum internal to external rotation at 0°, 45°, and 90° of abduction, and a maximum flexion/extension maneuver) and three static maneuvers (arm overhead, across the body, and behind the back) was completed in each case. Deidentified load data in lbf was collected and sorted based on which size liner was selected. Differences in means for minimum and maximum load values for the four dynamic maneuvers and differences in means for the three static maneuvers were calculated using 2-tailed unpaired t-tests. RESULTS. No significant differences were observed for the flexion/extension maneuver between the 38mm and 42mm liner sizes, but a significant difference was observed for every internal/external rotation assessment at 0°, 45°, and 90° of abduction. No significant differences were observed for the across the body and overhead maneuvers, but a significant difference was observed for the behind the back maneuver (p = 0.015).
Femoroacetabular Impingement (FAI) syndrome, characterised by abnormal hip contact causing symptoms and osteoarthritis, is measured using the International Hip Outcome Tool (iHOT). This study uses machine learning to predict patient outcomes post-treatment for FAI, focusing on achieving a minimally clinically important difference (MCID) at 52 weeks. A retrospective analysis of 6133 patients from the NAHR who underwent hip arthroscopic treatment for FAI between November 2013 and March 2022 was conducted. MCID was defined as half a